Product Profile - amspvtltd.com · Product Profile Fuels Biofuels Petroleum feedstock ... Seta...

8
Laboratory instruments for quality control, analysis and calibration Product Profile Fuels Biofuels Petroleum feedstock Crude oil Chemicals Lubricants Cosmetics Paints and varnishes Bitumens Recycled product

Transcript of Product Profile - amspvtltd.com · Product Profile Fuels Biofuels Petroleum feedstock ... Seta...

Laboratory instruments for quality control, analysis and calibration

Product Profile

Fuels

Biofuels

Petroleum feedstock

Crude oil

Chemicals

Lubricants

Cosmetics

Paints and varnishes

Bitumens

Recycled product

PRODUCT PROFILE

2 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

SETAFLASH SERIES 8 ACTIVECOOL CLOSED CUP TESTER (FLASH/NO FLASH & RAMP MODES) ASTM D3278; ASTM D3828; ASTM D7236; ASTM E502; IP 523; IP 524; IP 534; IP 303 (obs); ISO 3679; ISO 3680

• Flash/noflash&rampmode• Temperaturerangeof-20°Cto130°C(-4to266°F)• Smallsamplesize,2or4ml• CorrosionResistantcupoption• Electricignitor(withgasoption)• Automaticdippingandflashdetection• ActiveCoolelectronicPeltiercooling• 64Testmemory&RS232interface• °Cor°Ftemperaturedisplay

MULTIFLASH AUTOMATIC MULTI-METHOD FLASH POINT TESTERSPENSKY-MARTENS; ABEL; TAG; SMALL SCALE

• HighlyautomatedlowcostModularSystemwithin-builtsafety• Strictconformitytotestmethods• Fastandreliableperformance• GasorElectricIgnition• Temperaturein°Cor°F

SETAFLASH SERIES 3 ACTIVECOOL (RAPID EQUILIBRIUM AND RAMP TESTS) ASTM D3278; D3828; D7236; IP 303 (Obs); IP 523; IP 524; IP 534; ASTM E502; ISO 3679; ISO 3680

• Sub-AmbientTestsandRapidCoolDown• Temperaturerange10to135°C(50to275°F)• RapidEquilibriumandRamptests• CorrosionResistantoption• 1MinuteFlash/NoFlashandActualFlashPoint• 2/4mlSampleSize

SetaPartNo: 82100-0 82150-0 82000-0TemperatureRange: Air:10to130°C(50to266°F)

WaterAssisted:-20to130°C(-4to266°F)Air:10to130°C(50to266°F)WaterAssisted:-20to130°C(-4to266°F)

Ambient+5to300°C(Ambient+9to572°F)

TestModes: RapidEquilibriumandRamp RapidEquilibriumandRamp RapidEquilibriumandRampSampleSize: 2or4mlaccordingtomethod 2or4mlaccordingtomethod 2or4mlaccordingtomethodTestDuration,RapidEquilibriumMode:

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

TestDurationRampMode: Typically7minutes Typically7minutes Typically7minutesCupmaterial: Aluminium Corrosionresistingsteel AluminiumHeating/CoolingMethod: PeltierCell PeltierCell CeramicPad,ForcedAir(post-testcooldown)Size/weight: 30x34x38cм/8kg 30x34x38cм/8kg 30x34x38cм/8kg

SetaPartNo: 33200-2 33250-2 33000-0 30000-0TemperatureRange: 10to130°C(50to266°F) 10to130°C(50to266°F) Ambientto300°C Ambientto300°C (0to300°Cwith13870-0) (0to300°Cwith13870-0)TestModes: RapidEquilibriumandRamp RapidEquilibriumandRamp RapidEquilibriumandRamp RapidEquilibrium

SampleSize: 2or4mlaccordingtomethod 2or4mlaccordingtomethod 2or4mlaccordingtomethod 2or4mlaccordingtomethodTestDuration,RapidEquilibriumMode:

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

1minute<100°C,2minutes>100°CFAME1minuteoruserdefined1to99minutes

RampRate: 2°C/minramp 2°C/minramp 2°C/minrampCupmaterial: Aluminium Corrosionresistingsteel Aluminium AluminiumSize/weight: 26x28x26cm/5kg 26x28x26cm/5kg 26x28x26cm/4kg 26x28x26cm/4kg

82000-0➔

33200-2➔

34000-0+34100-2➔

81000-2➔

SetaModel: 34100-2 34200-0 34400-0 34700-0

Method: Pensky-Martens Abel TAG SmallScale

CupType: ClosedCup ClosedCup ClosedCup ClosedCup

Mode: ProcedureA,B,C,GB/T,Search NonEquilibrium,Equilibrium,Flash/NoFlash NonEquilibrium,Equilibrium,Flash/NoFlash Flash/NoFlash,NonEquilibrium,Search

TemperatureRange: Ambientto400°C Ambientto93°C,(5to93°Cwithcooling) Ambientto93°C,(5to93°Cwithcooling) Ambientto300°C(-20to300°Cwithcooling)

IgnitionMethod: ElectricorGas ElectricorGas ElectricorGas ElectricorGas

FlashDetection: Thermocouple Thermocouple Thermocouple Thermocouple

BathType: SolidBlock/Air Liquid/Liquid Liquid SolidBlock

PowerRequirement: 115Vor230Vac(switchable) 115Vor230Vac(switchable) 115Vor230Vac(switchable) 115Vor230Vac(switchable)

Size(HxWxD): 34x47x42cm 44x47x42cm 34x47x42cm 34x47x42cm

Weight(inc.Baseunit): 12kg 12kg 12kg 12kg

33T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

PRODUCT PROFILE

81000-2 SETAVAP 2 RAPID AUTOMATIC VAPOUR PRESSURE TESTER ASTM D5191; IP 409; IP 481; IP 394, EN 13016; Correlates with ASTM D323; D5842; D6378; IP 69; IP 402 (Obs)

• Multi-Mode-Ptot,DVPE,EPA,Crude,Pabs• FixedLiquid/Vapourratio• “Mini”methodusesonly3mlsamplesize• AutomaticDrainandPurge

Aquickandsimpletouseinstrumentfordeterminingthevapourpressureofgasoline,solvents,lightcrudeoils,andsimilarproductsusingthe“Mini”testmethod.

SetaVap2ishighlyautomatedwithstepbystepinstructionsandpromptsbeingdisplayedonthecontrolpanel.Oncethetestprocedurehasbeenstartedoperatorinterventionisonlyrequiredtoinjectthesampleintothechamber,eventhepurgingandcleaningcycleiscarriedoutautomatically.

12200-3 SETA EXISTENT GUM SOLID BATH ASTM D381-IP 131; IP 540; BS 2000 Part 131; BS 4348 (obs); ISO 6246; DIN 51 784; NF M07-004; FTM 791 3302; JIS K2261

• 5Teststations• Integralsteamsuperheater• Digitaltemperaturecontrol• 140to260°Ctemperaturerange• Flowgaugecalibratedforairandsteam

A SolidBlockBathdesignedtocarryoutuptofivesimultaneoustestsfordeterminingexistentgumcontentinfuelsbytheJetEvaporationmethod.

TestPressureRange: 0to200kPa±0.5kPa(0.1kParesolution)UnitsofMeasurement: kPaorpsi(userselectable)ChamberTemperature: 37.8°C(100°F)±0.1°CModes: Ptot,DVPE,EPA,Crude,PabsPowerRequirement: 115Vacor220Vac(switchable),50/60Hz,70WSize(HxWxD)/Weight: 37x13x20cm/3.5kg

Operatingtemperaturerange: 140to260°C±5°CHeaters: 2x1kWOver-temperaturecut-out: 280°C(adjustable)Air/Steaminlet: 15mmo.dpipeSize(HxWxD): 45x35x50cmWeight: 45kg

81000-2➔

11860-3 SETASTILL DISTILLATION UNIT ASTM D86; D216 (obs); D447 (obs); D850; D1078; E133; IP 123; IP 191; IP 195

• Ambientto400°Cdistillationrange• Adjustableheightheater/flaskplatform• Toughenedglasswindow• Coolingfan

Thedistillationunit,mountedtotheleft,comprisesaflasksupportmechanism,heaterelements,andtheheatercontroller.Theflaskissupportedbyadrop-inceramic-glasssupportboardmountedtoaplatformthatisadjustableforheight.Thequartzenclosedheatingelementsareattachedtotheplatform,andarepoweredbyasolid-stateenergyregulatorandcalibratedcontrol.Acoolingfanisinstalledintherearofthedistillationunittoreducecoolingtimebetweendistillations.Atoughenedglassobservationwindowisfittedinthefrontofthedistillationunit,andaspillagecollectiontraywithoutletismountedbeneaththeheaters.

DistillationRange: Ambientto400°CVoltageRange: 110/120Vor220/240V,50/60Hz(switchable)Power: 1000WmaximumCondenserVolume: 7.2litre

Size(HxWxD)/Weight: CondenserUnit:47x37x25cm,DistillationUnit:47x21x21cm/12kgtotal

11860-3➔

12200-3➔

PRODUCT PROFILE

4 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

MaximumRCF: 72.5kgMaximumRPM: 3000TemperatureRange: 30to80°C±2°CTimerRange: 1to60minutesin1minutesteps,ContinuousOperationRotorCapacity: 4SamplesPowerRequirement: 230Vac(110Vtransformeroption)50/60Hz/1kWSize(HxWxD)/Weight: 40.1x56.41x63.93cm/86kg

Temperaturerange: Ambient+5°Cto150°CTemperaturestability: ±0.1°CBathfluid: WaterorOilsBathcapacity: 35LitresWaterInletNozzle: 10mm

Overflowdrain: 10mm

90000-3 SETA OIL TEST CENTRIFUGE FOR SEDIMENT & WATER IN CRUDE OILASTM D91; D96 (Obs); D893; D1290; D1796; D1966; D2273; D2709; D4007; IP 75 (Obs); IP 539 (Obs)

• Specificallydesignedfortestingoils• Heatedchamber,ambientto80°C• Static,nearverticalbucketpositioning• 4placeswingoutrotor• Membrane‘touch’controlpanel• Pre-heatfacilitytoensurebowlisattesttemperaturepriortotest• ConformstoIEC1010-1&1010-2-Dsafetyrequirements

Withatemperaturerangeof30to80°Candarotationalspeedofupto3000rpm,thisheatedchambercentrifugeisspecificallydesignedfortestingoils.Thelargediameterchamber,fourplacerotorandcushionedadaptorsallowtheuseofthecorrect6and8inchconical,pear-shapedandtracesedimenttubesasspecifiedbythevarioustestmethods.Theswingoutrotorensuresthatthesamplesareheldnearverticalwhenatrestallowingmoreprecisemeasurementofsediment.

11400-6 SILVER AND COPPER CORROSION BATHASTM D130-IP 154, ASTM D4048, ASTM D4814, BS 2000 Parts 112 & 154, DIN 51 811, EN 2160, FTM 791 5325, IP 112, IP 227 (obs), IP PM-DJ 2005, JIS K2513, NF M07-015

• Ambient+5°Cto150°Ctemperaturerange• 9teststations• Copper/Silvercorrosiontests

TheSilverandCopperCorrosionBathisastainlesssteelwateroroilbathdigitallytemperaturecontrolledto±0.1°Coveratemperaturerangeofambient+5°Cto150°C.

90000-3

99700-4 SALT CONTENT IN CRUDE ANALYSERASTM D3230; IP 265

• ASTMandIPmethods• Automaticsaltconcentrationcalculation• Pre-calibratedforimmediateuse• 2userdefinedcalibrationmodes• RS232interface• Batteryormainsvoltageoperation• Weatherproof

Aportableinstrumentfordeterminingtheapproximatechloride(salts)contentofcrudeoils.Theinstrumentisprecalibratedandautomaticallycalculatesthesaltconcentrationing/m3orpoundsperthousandbarrels(ptb)(lb/1000bbl).MeasurementscanbedisplayedordownloadedtoaPC.Suppliedwithcarrycase,mainsadaptor,software,RS232cable&instructionmanual.

Conductivityrange: 0.0to151lb/1000bbl(Res:0.1lb/1000bbl)0.0to430.0g/m3(Res:0.1g/m3)

Temperaturerange: -20to150°C(Res:0.1°C)Powersupply: 9voltdcbatteryormainsadaptor

110/120/220/240,50/60HzadaptorsuppliedSize(HxWxD): 20x7x3.5cmWeight(includingcarrycase): 1.6kg

99700-4

11400-6

55T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

PRODUCT PROFILE

MeasuringPrinciple: ConstantVolumeCombustionChamberInjectionSystem: PintleType,singleholenozzle,airactuatedComputer: PentiumbasedPCwithinterfaceandscreen(supplied)CompressedGasRequirement: Air(20.9%O2)forcombustion,Air(IndustrialGrade)for

actuation,Nitrogen(IndustrialGrade)forfueldeliveryPowerRequirement: 120/220Vac@60Hzor220Vac@50HzSize(HxWxD)/Weight: 151x98x57cm/125kg

92000-3 IGNITION QUALITY TESTER (lQT™) - DERIVED CETANE NUMBER ANALYSIS EN 15195: 2005(E); ASTM D6890; IP 498; Correlates with ASTM D613

• AllDieselFuelsandBiodiesel• AutomatedTestProcedure• Small(<100ml)Sample• 20MinuteTest• Preciseresults-repeatabilityof0.91,reproducibility2.66@51CN• ApprovedspecificationtestforEN590,ASTMD975,D7467,BS2869

TheIgnitionQualityTester(IQT)isareliable,affordableandapprovedalternativetoacetaneengine.Itisafullyautomatedtestinstrumentforderivingthecetanenumberforawiderangeofmiddledistillatefuelsincludingconventionalandoilsands-baseddiesels,biodiesels,refinerystreams,plusfuelsusingoxygenateandnitratebasedcetaneenhancers.

92000-3➔

FilterBlockingTendency(FBT)Range: 1.0to30(lownumberbest)FilterabilityQualityFactor(FQF): 100to1(highnumberbest)MaximumPressure: 200kPaPowerRequirement: 110/120Vacor220/240Vac(switchable)Size(HxWxD)/Weight: 27x43x26cm/10kg

91600-3 SETA MULTI FILTRATION TESTER - PORTABLE TEST FOR FILTERABILITY/BLOCKING TENDENCY ASTM D2068; IP 387 (Procedures A, B & C); Correlates with ASTM D6426 NEW IP PM EA/08 Cold Soak Test Method for EN 590 Biofuel and FAME material.

• Compactandeasytouse• Resultinlessthan15mins• InterfaceforPCorPrinter

TheMFTisauniqueinstrumentdesignedtotesttheFilterBlockingTendency(FBT)andFilterabilityQualityFactor(FQF)ofdiesel,biodiesel(B100&B5/7/20),gasoil,gasturbinefuelandkerosine.

TestparametersforIP387/D2068andD6426testarepre-programmed.

91600-3➔

Setapartno: 94100-3 93531-7TemperatureRange: Ambientto-34°C Ambientto-51°CNumberandVolumeofCompartments: 3compartments,2litreseach 4compartments,2litreseachTotalNoofTestWells: 12 16CooldownTime: 1hourapprox.(32to-34°C) Approx2hrs(from32°Cto-51°C)PowerRequirement: 110/120Vacor220/240Vac,50/60Hz,750W 110/120V,60Hz220/240V,50Hz/1.8kWSize(HxWxD)/Weight: 60x60x85cm/115kg 95x63x63cm/115kg

94100-3 SETA COMPACT CLOUD AND POUR POINT CRYOSTAT FOR COLD FLOW TESTS ASTM D2500-IP 219, ASTM D5853-IP 441, ASTM D6422, ASTM D97-IP15, BS 2000 Parts 15 & 219, DIN 51 597 (obs), EN 23015, FTM 791 201, ISO 3015, ISO 3016, JIS K2269, NF T60-105

• 3IndividuallyTemperatureControlledCompartments• 4AirWellsineachCompartment• LargeTwoLitreCapacityCompartmentsforTemperatureStability• SingleStageCFCFreeRefrigeration

Thecryostatisequippedwiththreeindividuallytemperaturecontrolledcompartments.Eachtwolitrecompartmentcanaccommodatefourairwells.The94100-3issuppliedwithacompartmentthermometerand12testjars,eachcomprisinggraduatedglassware,thermometercork,andinsulatinggasketanddisk.Alowertemperature(-51°C)fourcompartmentCloud&PourPointCryostatisalsoavailable,Setapartnumber93531-7.

5 www.stanhope-seta.co.uk

94100-3➔

PRODUCT PROFILE

6 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

16670-0 SETA OXIDATION SOLID BLOCK BATH - 4 WAY ASTM D525; IP 40

• 4position• Dryblock• Overtemperaturecutout• Smallfootprint• Stability±0.1°C

TheSetaOxiSolidBlockBathisanaluminiumblockbathwithdigitaltemperaturecontrolthathasbeendesignedtoacceptuptofouroxidationvesselsforcarryingouttestsequivalenttotheIP40/D525testmethod.

TemperatureRange: Ambientto120°CStability: ±0.1°CBathCapacity: 35litresVoltage: 110/120V,50/60Hzor220/240V,50/60HzSize(HxWxD): Bath:44x35x26cm,OxfloControlUnit:64x36x33cmWeight: Bath:15kg,OxfloControlUnit:11kg

TemperatureRange: Ambient+5°to100°CBathType: DryBlockMaxNo.ofTestVessels: 4Heat-UpTimeto100°C: 80mins

16960-0 SETA 6 WAY OXIDATION BATH WITH WINDOW + OXFLO ASTM D943; D2274; D4310; D7462; IP 157; IP 388

• 6positionoilbath• Reliabledigitalthermostirunit• SetaOxfloControllerandflowmetersincluded• Lowliquidprotection• Overtemperaturecutout• Lighttightviewingwindow

Oilbathandoxygenflowcontrolunitusedforquantativeanalysisofthetendencyofoilsandfuelstoformsludge,acidsanddepositswhenexposedtooxygeninthepresenceofmetalliccatalystsoverextendedperiods.

TheseparateOxflocontrolunit(notshown)includesagasinletpressureregulator,pressuregaugeandsixprecisionflowmeterscalibratedforoxygenat3litres/hour,21°Cand0.4barpressure.Safetyfeaturesincludelowlevelliquidprotectionandovertemperaturecut-outs.

16960-0➔

16670-0➔

TemperatureRange: Ambientto150°C

TemperatureStability: ±0.01°upto100°C±0.02°between100and150°C

TemperatureUniformity: ±0.02°at40and100°C

TubeCapacity: upto6

BathFluid: OilorWater

BathCapacity: 50Litres

Size(HxWxD): 56x35x44cm

Weight: 33kg

84200-0 KV6 VISCOMETER BATH ASTM D2170-IP 319, ASTM D445-IP 71, ASTM D446, BS 188, BS 2000 Parts 71 & 319, DIN 51 366, DIN 51 562, EN 12595, EN 3104, FTM 791 305, ISO 3105, JIS K2283, NF T60-100, NF T60-136

• Upto6viscometertubes• 50litreoil/waterbath• Temperaturestability±0.01upto100°Cand±0.02between100and150°C• Temperaturerangeambientto150°C• Digitaldisplaywith0.01°Cresolution• Toughenedglassfrontpanel• Integralbacklighting

TheSetaKV-6hasa50litretemperaturecontrolledbaththatcanaccommodateuptosixstandardviscometertubes.Digitaltemperaturecontrolandaninbuiltcoldwatercoolingcoilprovideaccurateandstabletesttemperaturesfromambientto150°C(±0.01°Cupto100°Cand±0.02°Cbetween100and150°C).Thebathisprotectedbylowliquidlevelandovertemperaturecut-outs.

Equippedwithatoughenedglassfrontwindow,easilyaccessibledrainvalve,integralbacklighting,topplate,provisionforreferencethermometerandattachments.

84000-0

77T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

PRODUCT PROFILE

SETA REFERENCE & VERIFICATION MATERIALS – SINGLE & MULTI TEST VERIFICATION MATERIALSProducts: Diesel, Biodiesel, Gasoline, Jet & Lubricating Oil

• VerificationtoASTM/CEN/ISO/IP• TraceabletoISO9001:2000• 18MonthValidity

AllSetainstrumentsaremanufacturedtothehighestpossiblestandardstoprovideaccurate,reliableandrepeatableresultsdemandedbymodernlaboratories.TomaintaintheconfidenceofthosewhousetheresultsitisessentialtocarryoutregularverificationofthoseresultsandalsotomaintainthecalibrationofSetainstruments.

TherangeofSetaVerificationMaterialsforfuelstestingincludes;

• SimulatedDistillation(SIMDIS)• WaterdeterminationbyKarlFischer• LubricityofUltraLowSulphurDiesel(ULSD)byHFRR• VapourPressurebyevacuatedchambertest• RefereevaluesforLowSulphurGasolinemeetingASTMandIPtestmethodprotocols

TherangeofSetaVerificationmaterialsincludes‘MultiTest’samples,whichareauniquesecondaryreferencematerialthatprovidetraceablevalidationofseveraldifferenttestparametersfromonesourceofsample.

99708-0➔

isinstruments.

Conductivityrange: 0-2000pS/m±2pS/m(±2%ofreading)Resolution: 0.1pS/mTemperatureRange: 0-35°C*(±0.1°C)Size(HxWxD): 31x11x10cmWeight: 0.5kg

86400-2 PORTABLE FUEL INTEGRITY TEST KIT - RAPID CHECK FOR CONTAMINATION IN AVIATION FUEL

• SuitableforJetfuelandotherlightdistillatefuels• Multipletestsinsinglekit• Compact,easytocarryrucksack• IdealforshipboarduseforCargoInspectionandassurance

Aselfcontainedkitoftestequipmentforrapiddetectionofcontaminationinfuels.Thekithasbeendesignedtofitintoasmallpurposemaderucksackenablingittobeeasilytransportedtotestsiteswhichhaveonlylimitedordifficultaccess.Itisideallysuitedforshipboarduseprovidingbothrapidandeasyverificationofproductintegritypriortooff-loading.

Thekitcomprisesof5keyteststhatallowgo/nogotestingoffuels;

•Flashpoint(ASTMD3828)–usingtheSeries3ClosedCupTester,completewithsyringesandportablegassupply•Density–AnATEXapproveddigitaldensitymeter,IP559•Conductivity(ASTMD2624)–UsingadigitalconductivitymeterWaterContent-ShellWaterCapsulesofferdetectionto30ppm(80tests&syringes)•Digicell–DigitalreadoutofWatercontent,100-3000ppm,200-10000pmand0-10%(50tests)

99708-0 HAND HELD CONDUCTIVITY METERASTM D2624; IP 274

• HigherAccuracyACMeasurement(±2%ofreading)• Conductivityandtemperatureoutputcapability• Storesupto10DataLocations• USBinterfaceforeaseofdatatransfertouser• FullyTemperatureCompensatedMeasurement

TheSetaHandheldConductivityMeterprovidesanaccurateandrapidconductivitymeasurementofdistillatefuels;andisspecificallydesignedfortestinglowconductivityfluidssuchasaviationkerosene,ULSD,homeheatingfuel,Naphtha,andprintingink.

86400-2

99708-0➔➔

PRODUCT PROFILE

8 T +44 (0) 1932 564391 F +44 (0) 1932 568363 E [email protected] W www.stanhope-seta.co.uk

Seta Analytics provide analytical solutions for Hydrocarbon Petroleum products. It is a division of Stanhope-Seta which combines long established experience of testing petroleum products with the latest measurement technologies to provide enhanced analytical solutions for exploration, refining, petrochemical, distribution and marketing operations.

Current developments include laser based measurement for particle counting, electrochemical sensors for H2S detection and miniature FTIR technology for low level detection of FAME in Jet Fuels.

London StreetChertseySurrey KT16 8APEngland

T + 44 (0) 1932 564391F + 44 (0) 1932 568363E [email protected] www.stanhope-seta.co.uk

Analytical solutions for hydrocarbon petroleum products

H2S AnalyserASTM D7621, IP 570, ISO 8217 Marine Fuel Specification

FIJI - Fame in Jet InstrumentRapid Screening to IP 583