PRODUCT POCKET CATALOG

85
NEW - Now Featuring H eF Series ® Residential & Light Duty Commercial H ElectriFLEX HD Built to be the Best PRODUCT POCKET CATALOG FPC-0516 © 2016, Bradford White Corporation. All Rights Reserved. Visit us on the web at: www.bradfordwhite.com Ambler, PA Bradford White Corporation Subsidiary Companies Committed to American Manufacturing, Wholesale Distribution, and Professional Installation. For questions regarding where to purchase water heaters or who your local Bradford White representative is, contact the Sales Department: 800-523-2931 • Fax: 215-641-1670 For questions regarding tank and/or parts warranty and limitations on warranties, contact our 24/7 Warranty Support: 800-531-2111 • Fax: 269-795-1089 email: [email protected] For technical questions during and after installation such as how to diagnose and/or solve issues in the field, contact our 24/7 Technical Support: 800-334-3393 • Fax: 269-795-1089 email: [email protected] For product sizing, performance, application, and clarification questions before installation, contact the Product Department: 844-235-4958 email: [email protected] Bradford White Product Pocket Catalog - 2016 FPC-0516 © 2016, Bradford White Corporation. All Rights Reserved. Committed to American Manufacturing, Wholesale Distribution, and Professional Installation. www.bradfordwhite.com

Transcript of PRODUCT POCKET CATALOG

Page 1: PRODUCT POCKET CATALOG

NEW - Now Featuring H eF Series® Residential & Light Duty Commercial H ElectriFLEX HD™

Built to be the Best™

P R O D U C T P O C K E T C A T A L O G

AMERICAM A D E I N

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Visit us on the web at: www.bradfordwhite.comAmbler, PA

Bradford White Corporation Subsidiary Companies

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

For questions regarding where to purchase water heaters or who your local Bradford White representative is, contact the Sales Department:800-523-2931 • Fax: 215-641-1670

For questions regarding tank and/or parts warranty and limitations on warranties, contact our24/7 Warranty Support:800-531-2111 • Fax: 269-795-1089email: [email protected]

For technical questions during and after installation such as how to diagnose and/or solve issues in the field, contact our24/7 Technical Support: 800-334-3393 • Fax: 269-795-1089email: [email protected]

For product sizing, performance, application, and clarification questions before installation, contact theProduct Department:844-235-4958email: [email protected]

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Page 2: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

ContentsResidential Water HeatersGASAtmospheric Vent High EF ............................................................................. 6/7Atmospheric Vent Damper ............................................................................. 8/9Atmospheric Vent Models .......................................................................... 10/11Atmospheric Vent High Input ..................................................................... 12/13Direct Vent ................................................................................................. 14/15High Efficiency eF Series® Power Vent ...................................................... 16/17Power Vent (TTW®) ................................................................................... 18/19Power Direct Vent ...................................................................................... 20/21Manufactured Home Closed Combustion/Direct Vent ................................ 22/23Manufactured Home Atmospheric Combustion ......................................... 24/25Ultra Low NOx Atmospheric Vent Damper ................................................. 26/27Ultra Low NOx Atmospheric Vent .............................................................. 28/29Ultra Low NOx Atmospheric Vent High Input ............................................ 30/31Ultra Low NOx TTW® Power Vent .............................................................. 32/33Ultra Low NOx Power Direct Vent .............................................................. 34/35Ultra Low NOx Direct Vent ......................................................................... 36/37Infiniti Tankless™ High Efficiency ............................................................... 38/39Infiniti Tankless™ Mid Efficiency ................................................................. 40/41

ELECTRICGeneral Information ................................................................................... 42/43AeroTherm™ Series Heat Pump .................................................................. 44/45Upright Models .......................................................................................... 46/47Lowboy Models ......................................................................................... 48/49Wall Hung .................................................................................................. 50/51Utility ......................................................................................................... 52/53Powerful Compact®.................................................................................... 54/55KwickShot® Instantaneous Water Heaters ................................................. 56-59

SOLAREcoStor2™ Double-Wall Gas Backup .......................................................... 60/61EcoStor2™ TTW® Power Vent Double-Wall Gas Backup............................. 62/63EcoStor™ Open Loop Gas Backup .............................................................. 64/65EcoStor™ TTW® Power Vent Open Loop Gas Backup................................. 66/67EcoStor2™ SC Ultra Low NOx Double-Wall Gas Backup ............................ 68/69EcoStor™ Dual Coil Heat Exchanger Backup ............................................... 70/71EcoStor™SC Single-Wall Electric Backup.................................................... 72/73EcoStor2™ Double-Wall Electric Backup Models ........................................ 74/75Solar Saver® Electric Backup ..................................................................... 76/77

HYDRONIC SPACE HEATINGCombi1™ Single-Wall Atmospheric ............................................................ 78/79Combi1™ TTW® Single-Wall Power Vent Models ....................................... 80/81Combi2™ Double-Wall Atmospheric Models .............................................. 82/83Combi2™ TTW® Double-Wall Power Vent................................................... 84/85

INDIRECTSPowerStor Series® Single-Wall Indirect ..................................................... 86/87PowerStor2™ Series Double-Wall Indirect .................................................. 88/89Powertor Series® SS Stainless Steel Single-Wall Indirect ......................... 90/91

STORAGE TANKSStorage Tank .............................................................................................. 92/93

Commercial Water HeatersGASLight Duty Atmospheric Vent High Input ................................................... 96/97Light Duty High Efficiency eF Series® Power Vent ..................................... 98/99Light Duty TTW® Power Vent ................................................................ 100/101Light Duty Power Direct Vent ................................................................ 102/103Light Duty Direct Vent ........................................................................... 104/105Light Duty Ultra Low NOx Atmospheric Vent High Input ....................... 106/107

Light Duty Ultra Low NOx Direct Vent ................................................... 108/109Light Duty Ultra Low NOx TTW® Power Vent ........................................ 110/111Light Duty Ultra Low NOx Power Direct Vent ........................................ 112/113Commander Series™ Atmospheric Vent ................................................. 114/115Electronic Ignition Water Heaters .......................................................... 116-119Induced Draft ......................................................................................... 120/121Millivolt .................................................................................................. 122-125Ultra High Efficiency Models .................................................................. 126-129

ELECTRICGeneral Information ............................................................................... 130/131ElectriFLEX LD™ (Light Duty) Upright .................................................... 132/133ElectriFLEX LD™ (Light Duty) Lowboy .................................................... 134/135ElectriFLEX LD™ (Light Duty) Utility ....................................................... 136/137ElectriFLEX LD™ (Light Duty) Wall Hung ................................................ 138/139ElectriFLEX MD™ (Medium Duty) ........................................................... 140/141ElectriFLEX HD™ (Heavy Duty) ............................................................... 142/143Surface and Immersion Thermostat Models .......................................... 144/145ASME Models ........................................................................................ 146/147Brute Vertical Round .............................................................................. 148/149GPH Recovery Table for kW Input ......................................................... 150/151

INDIRECTSPowerStor Series® Single-Wall Indirect ................................................ 152/153

STORAGE TANKSJacketed Storage Tank ........................................................................... 154/155Large Volume Jacketed Storage Tank .................................................... 156-159Large Volume Unjacketed Storage Tank ................................................ 160-163Large Volume Vertical Topcoat Storage Tank Models ........................... 164-167

Warranty Information ..............................................................................168Tank Type Serial Number Indentification ...........................................169

1. All Gas Water Heaters are design certified by CSA International (formerly AGA and CGA) in accordance with ANSI Z21.10.1 or 10.3 (latest addition). Closed Combustion Manufactured Home Water Heaters, are listed by Intertek (ETL).

2. All Electric Water Heaters are listed by Intertek (ETL).

3. All Residential Storage Models meet or exceed efficiency requirements of the Department of Energy. ASHRAE standard 90.1b (current standard) and the National Appliance Energy Conservation Act of 1987, recent amendment effective April 16, 2015 which supercedes all state and local efficiency requirements.

4. All Tank Type Water Heaters are certified at 300 PSI test pressure and 150 PSI working pressure (except where noted).

5. All Residential and Light Duty Water Connections are 3⁄4" NPT on 8" centers (except where noted).

6. All Residential and Light Duty Gas Models have 1⁄2" NPT Gas Connections (except where noted).

7. All Residential Water Heaters come with a T&P Relief Valve included (except where noted).

8. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012.

9. All dimensions are in inches (unless otherwise noted). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

10. All products manufactured by Bradford White Water Heaters are designed, fabricated, and assembled in Middleville, MI. All raw materials and component parts are sourced from American companies for the highest level of American made content and manufacture, whenever possible.

CSA International National Sanitation Foundation

American Society of Mechanical Engineers Heating Boilers

American Society of Mechanical Engineers Lined Potable Water Heaters

National Board of Boiler and Pressure Vessel Inspectors

Air-Conditioning, Heating, and Refrigeration Institute

Compliance, Safety, Accountability

Intertek Underwriters Laboratories

General Information About the Products in this Catalog

page 2

page 3

Page 3: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

The Family of Hydrojet® Systems This Is Technology That Works!

Hydrojet® Total Performance SystemThe Hydrojet® Total Performance System is a cold-water delivery tube that reduces sediment buildup and thoroughly mixes incoming water with stored water reducing thermal stratification. The secret is a series of flow altering “jet ports”. These ports create counter-rotation and dynamic turbulence that effectively blasts sediment into suspension and prevents its accumulation.

The Hydrojet® Total Performance System also causes more efficient temperature mixing inside the tank. Heating efficiency and usable hot water delivery are greatly increased, thereby saving energy and money.

The upper “jet ports” direct the flow outward to begin the dynamic mixing action.

The Hydrojet® System’s jet ports create a churning outflow that puts sediment into suspension. This turbulent action helps reduce sediment and prevent its accumulation.

The Family of Hydrojet® Systems This Is Technology That Works!

The lower “jet ports” direct the flow inward to increase pressure and turbulence.

Commercial Hydrojet® Sediment Reduction System The commercial Hydrojet® was designed to block the build-upof harmful sediment in commercial units by increasingturbulence with accelerated water current inside the tank.It incorporates up to two inlet tubes. One is the traditional topconnect version and the other is a front connection configuration.

Hydrojet®2 Total Performance SystemMuch like the original Hydrojet® Total Performance System, this cold water inlet device minimizes sediment build up, increases delivery and reduces thermal stratification. The Hydrojet®2 is specifically designed for higher input applications. It utilizes additional jetports to initiate beneficial temperature mixing higher in the tank thereby increasing usable hot water.

“Make the Switch to Bradford White”

page 4

page 5

Page 4: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

J

H

C

A

G

E

D

F

B

J

H

C

A

G

E

D

F

Photo ofRG2F40S6N

Residential GasAtmospheric Vent High EF Models

6/7

l ENERGY STAR® Qualifiedl High Efficiency Blower

- 10 ft. Power Cord Included (120 VAC)l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control

System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring

the patented Advanced ScreenLok® Technology flame arrestor design

- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPT

true dielectric fittings

l Heat Trapsl Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl T&P Relief Valvel Low Restriction Brass Drain Valve

38,00038,000

4050

� RG2F40S6N� RG2F50S6N

7084

541/4551/4

2224

40405/8

150176

113/4113/4

3 x 43 x 4

NATURAL GAS AND LIQUID PROPANE GAS MODELS Recovery90°F Rise*

A

Floor toFlue Conn.

1st HourRating(Gal.)

0.700.70

EnergyFactor

4141

U.S.GPH

3333

Imp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

4748

F

Floor toTop ofHeater

477/8487/8

G

Floor toWaterConn.

257/8277/8

H

Depth

88

J

C/Lof WaterConns.

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. 120V, 60Hz. 1 Amp. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.

Atmospheric Vent High EF Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 6

page 7

Page 5: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

JH

A

G

F

E

D

C

B

JH

A

G

F

E

D

CPhoto of

RG2D40S6N

Residential GasAtmospheric Vent Damper Models

8/9

l ENERGY STAR® Qualified—Some modelsl Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Automatic Flue Damper

- 10 ft. Power Cord Included (120 VAC)l Defender Safety System® featuring the

patented Advanced ScreenLok® Technology flame arrestor design

- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPT true dielectric

fittingsl Heat Traps

l Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl T&P Relief Valvel Low Restriction Brass Drain Valve

32,00040,00040,00040,00038,00040,000

304040504050

RG1D30T6N• RG1D40S6N• RG1D40T6N• RG1D50T6N•� RG2D40S6N� RG2D50S6N

587476897286

63577/8633/8633/8541/2631/2

162018202222

497/841

501/8497/8407/8497/8

116147134160155174

13131313

113/4113/4

3 x 43 x 43 x 43 x 43 x 43 x 4

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor toFlue Conn.

1st HourRating(Gal.)

0.650.620.620.600.670.67

EnergyFactor

344343434143

NatU.S.GPH

283636363436

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

561/448

569/16

569/16

4711/16

561/2

F

Floor toTop ofHeater

57491/8573/4573/4487/858

G

Floor toWaterConn.

203/4243/4223/4243/4261/8261/8

H

Depth

88881111

J

C/L ofWaterConn.

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. 120V, 60Hz. 12 Amps. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.

• Models feature optional top T&P location and must be specified when ordering. RG1D30T6X• RG1D40S6X• RG1D40T6X• RG1D50T6X•� RG2D40S6X� RG2D50S6X

LP GAS MODELS InputBTU/Hr.

31,00038,00038,00038,00038,00040,000

Recovery90°F Rise*

334141414143

LPU.S.GPH

283434343436

LPImp.GPH

ModelNumber

Atmospheric Vent Damper Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 8

page 9

Page 6: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

A

F

D

E

F

B

8"

C

G

A

F

D

E

F

B

8"

C

G

Photo ofRG240T6N

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring the patented

Advanced ScreenLok® Technology flame arrestor design

- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPT true

dielectric fittingsl Heat Trapsl Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverter

l T&P Relief Valve l Low Restriction Brass Drain Valve

Residential GasAtmospheric Vent Models

10/11

27,00032,00030,00034,00040,00040,00034,00040,00040,00050,000

30303040404050504850

RG130T6N•RG230T6N•RG230S6NRG140T6N•RG240T6N•RG240S6N•RG150T6N•RG250T6N•RG250L6NRG250S6N•

52585670767482898893

591/8593/4491/4611/4601/8511/2595/8601/2515/8601/2

191/2211/2231/2211/2231/2251/2231/2251/2271/2251/2

16182018202220222422

493/4 / 563/8497/8 / 563/8

385/8511/2 / 60

501/8 / 565/841 / 471/450 / 563/8497/8 / 57

405/8497/8 / 57

109116113132134139150154170167

13131313131313131313

3 x 43 x 43 x 43 x 43 x 43 x 43 x 43 x 43 x 4

4

Atmospheric Vent ModelsDIMENSIONS IN INCHES

NATURAL GAS MODELS

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency

Recovery 90°F Rise* A

Floor toFlue Conn.

1st HourRating(Gal.)

0.630.640.630.620.620.620.600.620.600.60

EnergyFactor

29343237434337434354

NatU.S.GPH

24283731363631363645

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

G

Depth

DFloor to

T&PConn.

EFloor to

GasConn.

571/2571/8461/2595/8579/16

493/16

58577/8493/8583/16

FFloor toWaterConn.

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency.• Models feature optional top T&P location and must be specified when ordering. Note: RG230S6N and RG250L6N do not have top T&P option. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

RG130T6X•RG230T6X•RG230S6XRG140T6X•RG240T6X•RG240S6X•RG150T6X•RG250L6XRG250T6X•RG250S6X•

LP GAS MODELS Input BTU/Hr.

27,00031,00032,00034,00036,00035,00034,00035,00035,00048,000

Recovery 90°F Rise*

29333237344137414152

LP U.S. GPH24232731333431343445

LP Imp. GPHModel Number

Atmospheric Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery EfficiencyDIMENSIONS IN INCHES

page 10

page 11

Page 7: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRG2100H6N

K

B

C

A

JF

E

D&M

L

NN

H

RG2100H6N

A

D&M

E

J F

B

H

N N

C

K

L

RG250H6N / RG275H6N

KB

C

J

F

E L

A

D&M

H

N N

RG155H6N

Residential GasAtmospheric Vent High Input Models

12/13

All Model Features (except RG155H6N):l Bradford White ICON

System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

All Model Features:l Hydrojet 2™ Total

Performance Systeml Vitraglas® Liningl Side Connections—3/4"

(19mm)l Non-CFC Foam Insulationl Pedestal Base

(RG250H6N / RG275H6N only)

l Water Connections

l Hand Hole Cleanout (RG2100H6N only)

l Protective Magnesium Anode Rod

l 4" (107mm) “Snap Lock” Draft Diverter

l T&P Relief Valvel Low Restriction Brass

Drain Valvel Thermostatic

Mixing Valve (ASSE Approved)—Included with RG155H6N only

65,00080,00076,00085,000

485575100

RG250H6NRG155H6NRG275H6NRG2100H6N

110N/AN/AN/A

60591/2625/869

222226

281/4

4915/16

497/8517/8595/16

189210249413

131413/16

15157/16

4444

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor to Flue Conn.

1st HourRating(Gal.)

0.60N/AN/AN/A

EnergyFactor

70868292

NatU.S.GPH

58726877

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

565/85515/16

59651/2

F

Floor toTop ofHeater

1181116

H

C/L ofWaterConn.

577/8577/8607/16

6615/16

J

Floor toWaterConn.

26257/8271/4311/2

K

Depth

131/2157/16

165/81711/16

L

Floor toSpace

Heating Inlet

4915/16

497/8517/8505/8

M

Floor toSpace

Heating Outlet3/43/41

11/4

N

NPT

Approx.Shipping

Weight (lbs)

* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”. RG155H6N not available as 10 year model. RG2100H6N model features hand hole cleanout. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

RG250H6XRG155H6XRG275H6XRG2100H6X

LP GAS MODELS InputBTU/Hr.

61,00078,00076,00088,000

Recovery90°F Rise*

66848295

LPU.S.GPH

55706879

LPImp.GPH

ModelNumber

Atmospheric Vent High Input Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 12

page 13

Page 8: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

J

H

F

E L

B

D&MK

C C

A A

K

Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)

Photo ofRG2DV50H6N

Residential GasDirect Vent Models

14/15

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics

- Separate Immersed Thermowelll Defender Safety System® featuring

the patented Advanced ScreenLok® Technology flame arrestor design

- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Closed Combustionl Reinforced Sealsl Maintenance-Freel Sight Windowl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kit

l Side Connections—3/4" NPT tappings (RG2DV50H6N only)

l 2" Non-CFC Foam Insulationl Water Connections—3/4" NPT—

True dielectric fittings

l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valve

38,00042,00050,000

405048

RG2DV40S6NRG2DV50S6NRG2DV50H6N

738893

631/2 min.

721/2 min.

757/8 min.

222222

433/8521/4521/4

189212234

151515

334

556

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor to C/L of Vent

1st HourRating(Gal.)

0.620.600.60

EnergyFactor

414554

U.S.GPH

343545

Imp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

I.D. O.D.

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

503/16

593/16

591/8

F

Floor toTop ofHeater

8118

H

C/L ofWaterConn.

511/8601/8601/8

J

Floor toWaterConn.

313131

K

Depth

——

153/4

L

Floor toSpace

Heating Inlet

——

521/4

M

Floor toSpace

Heating Outlet

Approx.Shipping

Weight (lbs)

All Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

RG2DV40S6N / RG2DV50S6N Solid Vent Kit: Part No. 239-51283-00. RG2DV40S6N / RG2DV50S6N Flexible Vent Kit: Part No. 239-51284-00.RG2DV50H6N Solid Vent Kit: Part No. 239-51286-00. RG2DV50H6N Flexible Vent Kit: Part No. 239-51287-00.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual. RG2DV40S6N / RG2DV50S6N Optional Telescoping Solid Vent Kits: Kit “A” Telescopes from 43⁄4" to 511⁄16" Part No. 239-41260-00 Kit “B” Telescopes from 61⁄2" to 93⁄16" Part No. 239-41331-00 Kit “C” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-41029-00 Kit “D” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-41424-00 RG2DV50H6N Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00

RG2DV40S6XRG2DV50S6XRG2DV50H6X

LP GAS MODELS InputBTU/Hr.

36,00040,00048,000

Recovery90°F Rise*

394350

U.S.GPH

323642

Imp.GPH

ModelNumber

Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 14

page 15

Page 9: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

C

A

G

F

E J

B

D & K

H

8"

Photo ofRC2PV50H6N

C

A

G

F

E J

B

D & K

H

8"

Residential GasHigh Efficiency eF Series® Power Vent Model 90%+ Thermal Efficiency

16/17

l Vertical, Dual-pass Heat Exchanger System

l Vitraglas® Protection—On both primary and secondary heat exchanger

l Self-priming Condensate Teel Power Ventl Horizontal and Vertical Ventingl Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Hydrojet® Total

Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Pedestal Basel Water Connections—3/4" NPTl 3/4" NPT Side Connections.

l Heat Trapsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve

2"Vent Pipe

3"Vent Pipe

4"Vent PipeRC2PV50H6N

†50 ft.7 ft.45 ft.40 ft.35 ft.

†120 ft.15 ft.115 ft.110 ft.105 ft.

†180 ft.15 ft.175 ft.170 ft.165 ft.

123

Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows

Subtract 5ft. for each additional 90° elbow.† For high altitude installations, consult the installation instructions.

76,00050RC2PV50H6N 671/4 24 461/2 225135/82, 3 or 4

NATURAL GAS AND LIQUID PROPANEGAS MODELS

Recovery90°F Rise*

Floor to Vent Conn.

93

U.S.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

Jacket Dia.

VentSize

Floor to T&P

Conn.

Floor toGas

Conn.

561/4

Floor toTop ofHeater

571/2

Floor toWaterConn.

273/8Depth

155/8

Floor toSpace

Heating Inlet

461/2

Floor toSpace

Heating Outlet

A B C D E F G H J K

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.* Based on 90.5% Thermal Efficiency.

High Efficiency eF Series® Power Vent Model 90%+ Thermal EfficiencyMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 16

page 17

Page 10: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRG2PV50H6N

B

H

K

C

J

F

E L

A

D&M

B

H

K

C

J

F

E L

A

D&M

Residential GasPower Vent (TTW®) Models

18/19

l ENERGY STAR® Qualified—Some modelsl Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Power Vented Water Heaterl Powerful Blower Motor

- 10 ft. Power Cord Included (120 VAC)l Horizontal and Vertical Ventingl Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Flammable Vapor Sensor

- Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Lining

l Non-CFC Foam Insulationl Water Connections—3/4" NPTl 3/4" NPT Side Connections (RG2PV50H6N,

RG1PV55H6N, and RG2PV75H6N only)l Heat Trapsl Protective Magnesium Rod (RG1PV55H6N

has two)l T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE Approved)

—Included with RG1PV55H6N only

40,00040,00040,00040,00065,00078,00076,000

40504050485575

RG1PV40S6N RG1PV50S6N� RG2PV40T6N� RG2PV50T6N� RG2PV50H6N RG1PV55H6N RG2PV75H6N

72867286112N/AN/A

575/16

581/4 667/8

667/8

661/8

643/16

697/16

20222022222226

40405/85050

501/8

4715/16

511/2

140166146173187219260

113/4113/4113/4113/4113/4111/2131/2

2 or 32 or 32 or 32 or 33 or 43 or 43 or 4

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor to VentConn.

1st HourRating(Gal.)

0.660.650.700.700.70N/AN/A

EnergyFactor

43434343708482

NatU.S.GPH

36363636587068

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

471/2481/4563/4563/4563/8545/8591/2

F

Floor toTop ofHeater

888811811

H

C/L ofWaterConn.

49501/25858

573/456

603/4

J

Floor toWaterConn.

277/8263/4241/2261/2263/4261/2301/4

K

Depth

N/AN/AN/AN/A131/2133/8133/8

L

Floor toSpace

Heating Inlet

N/AN/AN/AN/A501/8

4715/16

511/2

M

Floor toSpace

Heating Outlet

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”. RG1PV55H6N not available as 10 year model.*Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.

2" Vent Pipe

RG1PV40S6NRG1PV50S6NRG2PV40T6NRG2PV50T6N

†50 ft.7 ft.45 ft.40 ft.35 ft.

3" Vent Pipe

†120 ft.15 ft.115 ft.110 ft.105 ft.

3" Vent Pipe

RG2PV50H6NRG1PV55H6NRG2PV75H6N

†60 ft.7 ft.55 ft.50 ft.45 ft.

4" Vent Pipe

†180 ft.15 ft.175 ft.170 ft.165 ft.

123

Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows

2" Vent Pipe

RG2PV40T6NRG2PV50T6N

†50 ft.7 ft.45 ft.40 ft.35 ft.

3" Vent Pipe

†120 ft.15 ft.115 ft.110 ft.105 ft.

RG1PV40S6X RG1PV50S6X� RG2PV40T6X� RG2PV50T6X� RG2PV50H6X RG1PV55H6X RG2PV75H6X

LP GAS MODELS InputBTU/Hr.

38,00038,00040,00040,00058,00078,00075,500

Recovery90°F Rise*

41414343628481

LPU.S.GPH

34343636527067

LPImp.GPH

ModelNumber

† For high altitude installations, consult the installation instructions.

Power Vent (TTW®) Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 18

page 19

Page 11: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRG2PDV40S6N

K

C

J F

EL

B

D & M

A H

K

C

J F

EL

B

D & M

A H

Residential GasPower Direct Vent Models

20/21

l ENERGY STAR® Qualified—Some models

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics

- Separate Immersed Thermowell

l Defender Safety System®

- Flammable Vapor Sensor - Maintenance-Free

- Sight Window - Pedestal Basel Closed Combustion

Venting Systeml Powerful Blower Model

- 10 ft. Power Cord Included (120 VAC)

l Cast Aluminum Air Intake Bootl Horizontal and Vertical Venting

l Optional Concentric Vent Kit Termination

l Flammable Vapor Sensor (except RG2PDV75)

l Hydrojet® Total Performance System

l Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections— 3⁄4" NPTl Side Connections— 3/4"

NPT (RG2PDV50H6N and RG2PDV75H6N only)

l Heat Trapsl Protective Magnesium

Anode Rodl T&P Relief Valvel Low Restriction Brass

Drain Valve

40,00040,00060,00080,000

40504875

H RG2PDV40S6NH RG2PDV50S6NH RG2PDV50H6N RG2PDV75H6N

7286100—

5911/16

607/86972

22242226

421/2

431/2

521/4541/4

161192204291

1414

135/8161/4

2 or 32 or 33 or 43 or 4

Power Direct Vent ModelsDIMENSIONS IN INCHES

NATURAL GAS MODELS

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency

Recovery90°F Rise*

A

Floor toExhaustOutlet

1st HourRating(Gal.)

0.700.700.68—

EnergyFactor

43436586

NatU.S.GPH

36365472

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

491/2501/2583/4623/4

F

Floor toTop ofHeater

593/8603/867

703/8

H

Floor toAir

Intake

5013/16

5113/16

60633/4

J

Floor toWaterConn.

301/2321/2305/836

K

Depth

——

153/419

L

Floor toSpace

Heating Inlet

——

521/4541/4

M

Floor toSpace

Heating Outlet

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year model, change suffix “6” to “10”. * Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.

INTAKE/COMBUSTION

AIR

RAINCAP

VENTEXHAUST

A

Concentric Vent Kit Termination

2" Kit

P/N 239-44069-02 29 1/4

A (in.)

3" Kit

P/N 239-44069-01 36 1/4

A (in.)

2" Vent PipeRG2PDV40S6NRG2PDV50S6N

35 ft.35 ft.7 ft.30 ft.25 ft.20 ft.

123

Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows

3" Vent PipeRG2PDV40S6NRG2PDV50S6N

RG2PDV50H6NRG2PDV75H6N

85 ft.85 ft.7 ft.80 ft.75 ft.70 ft.

60 ft.60 ft.7 ft.

55 ft.50 ft.45 ft.

4" Vent PipeRG2PDV50H6NRG2PDV75H6N

100 ft.100 ft.7 ft.

95 ft.90 ft.85 ft.

H RG2PDV40S6XH RG2PDV50S6XH RG2PDV50H6X RG2PDV75H6X

LP GAS MODELS InputBTU/Hr.

38,00038,00060,00078,000

Recovery90°F Rise*

41416584

34345470

LPU.S.GPH

LPImp.GPH

ModelNumber

Power Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 20

page 21

Page 12: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

C

G

A

E

F

D

B

C

G

A

E

F

D

Photo ofRG2DVMH30T6X

Residential GasManufactured Home Closed Combustion/Direct Vent Models

22/23

l Housing and Urban Developmentl Sealed Combustion Roof Jack Kit—Must order for new installationsl Flue Bafflel Heat Trapsl Vitraglas® Liningl Fully Automatic Controlsl 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel Convertible Gas Control

30,00030,000

3040

RG2DVMH3OT6XRG2DVMH4OT6X

5259

579/16

571/41820

501/4501/2

119139

133/4133/4

33

NATURAL GAS AND LIQUID PROPANE GAS MODELS Recovery90°F Rise*

A

Floor toTop ofHeater

1st HourRating(Gal.)

0.630.62

EnergyFactor

3232

U.S.GPH

2727

Imp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floorto T&PConn.

E

Floor toGas

Conn.

221/2221/2

F

Floor toCold Water

Conn.

571/258

G

Floor toHot Water

Conn.

Approx.Shipping

Weight (lbs)

To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Optional Roof Jack Kits

Part Number12"

18" / 32"32" / 60" 48" / 90"

239-37022-01239-37022-02239-37022-03239-37022-04

A15"

331/2"321/2"- 621/2"

50"- 981/2"

BThrough The Roof

Clearance16"- 33"

331/2"- 66"371/2"- 74"

541/2"- 1091/2"

Includes: roof jack, hardware, air intake, instructions.

B

22.5° Max.

A11 5/8"Square

6 1/2"

7"

4"

5"

3"

9"

This water heater is of the closed combustion type (direct venting) for mobile home applications only, where all combustion air is supplied from the outdoors through the air intake and all combusted gas products are vented directly to the outside by means of the roof jack. No draft diverter (vent hood) is required for this water heater. The ETL listing of this water heater includes the field installation of the following components: roof jack, roof jack clamp, air intake, air intake seal, and heater tie down materials. These components for field installation are shipped with the heater in a separate box and must be installed according to instructions. No other components are approved for use with the water heater. The water heater must be installed in accordance with The Federal Mobile Home Construction and Safety Standard or in the absence of such standard, The Standard for Mobile Homes (ANSI/NFPA No. 601B-1977)

Manufactured Home Closed Combustion/Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 22

page 23

Page 13: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

K

C

G

A

H

E

F

D

B

K

C

G

A

H

E

F

D

Photo ofRG2MH30T6X

Residential GasManufactured Home Atmospheric Combustion Models

24/25

l Defender Safety System® featuring the patented Advanced ScreenLok® Technology flame arrestor design

- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Piezo Igniterl Housing and Urban Developmentl Roof Jack Kit—Must order for

new installationsl Vitraglas® Liningl Fully Automatic Controlsl Convertible Gas Controll 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Trapl Protective Magnesium Anode Rod

l 3"x4" “Snap Lock” Draft Diverterl Flue Bafflel Steel Tankl T&P Relief Valvel Low Restriction Brass Drain Valvel Design Certified by CSA International

(formerly AGA/CGA).

32,00034,000

3040

RG2MH30T6XRG2MH40T6X

5557

591/8593/8

1820

505/16

505/16

118135

1313

3 x 43 x 4

NATURAL GAS AND LIQUID PROPANE GAS MODELS Recovery90°F Rise*

A

Floor toFlue Conn.

1st HourRating(Gal.)

0.630.63

EnergyFactor

3437

U.S.GPH

2831

Imp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor toT&P

Conn.

E

Floor toCold Water

Conn.

221/2221/2

F

Floor toHot Water

Conn.

573/4573/4

G

Floor toHeater

Top

2022

K

Depth

567/8567/8

H

Floor toHeater

Top

Approx.Shipping

Weight (lbs)

To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Optional Roof Jack Kits

Part Number12"

18" / 32"32" / 60" 48" / 90"

239-37030-01239-37030-02239-37030-03239-37030-04

A15"

331/2"321/2"- 621/2"

50"- 981/2"

BThrough The Roof

Clearance16"- 33"

331/2"- 66"371/2"- 74"

541/2"- 1091/2"

Includes: roof jack, hardware, air intake, instructions.

B

C

G H

E

K

B

22.5° Max.

A11 5/8"Square

6 1/2"

7"

4"

5"

3"

9"

ANODE

AD

F

The water heater enclosure access door must be on the outside wall of the manufactured home (mobile home) only. Access to the water heater enclosure from the inside of the manufactured home (mobile home) is not permitted. The CSA International (formerly AGA/CGA) listing of this water heater includes the field installation of the following components: roof jack and heater tie down materials. These components for field installation are shipped in a separate box from the heater and must be installed according to instructions. No other components are approved for use with the water heater. The water heater must be installed in accordance with The Federal Manufactured Home Construction and Safety Standard Title 24 CRF, Part 3280.

Manufactured Home Atmospheric Combustion Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed77% Recovery EfficiencyDIMENSIONS IN INCHES

page 24

page 25

Page 14: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

G

C

A

F

E

D

B

G

C

A

F

E

D

Photo ofURG1D50T6N

Residential GasUltra Low NOx Atmospheric Vent Damper Models

26/27

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control - Intelligent Diagnostics - Separate Immersed Thermowelll Automatic Flue Damper

- 10 ft. Power Cord Included (120 VAC)l Eco-Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design

- Digital Thermal Sensor and Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary

and Secondary Air Distribution Devicesl Hydrojet® Total Performance Systeml Vitraglas® Liningl 1" Non-CFC Foam Insulation

l Water Connections—3⁄4" NPT l Heat Trapsl Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl T&P Relief Valve l Low Restriction Brass Drain Valvel Design Certified by CSA International (formerly

AGA and CGA).l Complies with the Latest Ultra Low NOx

Requirement (10 ng/J NOx limit)

32,00040,00040,00040,000

30404050

URG1D30T6NURG1D40S6NURG1D40T6NURG1D50T6N

58747689

635413/16

639/16

633/8

16201820

497/841

501/8497/8

120151138164

113/4113/4113/4113/4

3 x 43 x 43 x 43 x 4

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor toFlue

Conn.

1st HourRating(Gal.)

0.650.620.620.60

EnergyFactor

34434354

NatU.S.GPH

25363645

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor toT&P

Conn.

E

Floor toGas

Conn.

571/8491/8571/2577/8

F

Floor toWaterConn.

203/4243/4223/4243/4

G

Depth

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Ultra Low NOx Atmospheric Vent Damper Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 26

page 27

Page 15: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

G

C

F

E

D

A

B

G

C

F

E

D

A

Photo ofURG250T6N

Residential GasUltra Low NOx Atmospheric Vent Models

28/29

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design

- Digital Thermal Sensor and Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary and

Secondary Air Distribution Devicesl Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Traps

l Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl Flue Bafflel Steel Tankl T&P Relief Valvel Low Restriction Brass Drain Valvel Design Certified by CSA International

(formerly AGA and CGA)l Complies with the Latest

Ultra Low NOx Requirement (10 ng/J NOx limit)

27,00032,00034,00040,00040,00034,00040,00040,00050,000

303040404050504850

URG130T6N•URG230T6N•URG140T6N•URG240T6N•URG240S6N•URG150T6N•URG250T6N•URG250L6NURG250S6N•

525870767482908893

591/8597/8603/4601/4515/8595/8603/16

515/8591/2

161818202220222422

493/4 / 563/8497/8 / 563/8511/2 / 591/250 / 565/841 / 471/450 / 563/8497/8 / 57

405/8497/8 / 572

112119130137149153160174169

113/4113/4113/4113/4113/4113/4113/4113/4113/4

3 x 43 x 43 x 43 x 43 x 43 x 43 x 43 x 4

4

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor toFlue

Conn.

1st HourRating(Gal.)

0.630.640.620.620.620.600.620.600.60

EnergyFactor

293437434337434354

NatU.S.GPH

242831363631363645

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor toT&P

Conn.

E

Floor toGas

Conn.

571/257

591/8571/2491/858

585/16

493/8583/16

F

Floor toWaterConn.

191/2211/2211/2231/2251/2231/2251/2271/2251/2

G

Depth

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency.• Models feature optional top T&P location and must be specified when ordering. Energy Factor and First Hour Rating are based on the latest AHRI directory listings. (URG130T, URG140T, & URG150T available with top T&P location ONLY)

Ultra Low NOx Atmospheric Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 28

page 29

Page 16: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofURG250H6NModels URG250H6N & URG275H6N

BK

C

L

J

H

E F

A

D&G

M

B

C

K

A

J

E F

G

D

L

M

Model URG2100H6N

Residential GasUltra Low NOx Atmospheric Vent High Input Models

30/31

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System®

featuring the patented advanced ScreenLok® Technology flame arrestor design

- Digital Thermal Sensor and Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Defender Combustion Chamber

(URG250H6N only)l Ultra Low NOx Burner with

Primary and Secondary Air Distribution Devices

l Hydrojet® Total Performance Systeml Vitraglas® Lining

l Side Connections—3/4" NPTl Non-CFC Foam Insulationl Water Connectionsl Heat Trapsl Protective Magnesium

Anode Rodl 4" (107mm) “Snap Lock”

Draft Diverter.l T&P Relief Valvel Low Restriction Brass

Drain Valvel Design Certified by CSA

International (formerly AGA and CGA).

l URG250H6N Complies with the Latest Ultra Low NOx Requirement (10 ng/J NOx limit) URG275H6N / URG2100H6N complies with (14 ng/J NOx limit)

55,00076,00085,000

4875100

URG250H6NURG275H6NURG2100H6N

100N/AN/A

605/16

641/8707/16

2226

281/4

497/8539/16

607/16

194286416

111/2151/8163/4

444

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor to Flue Conn.

1st HourRating(Gal.)

0.60N/AN/A

EnergyFactor

598292

NatU.S.GPH

496877

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

133/8165/8183/4

F

Floor toSpace

HeatingReturn

497/8539/16

513/4

G

Floor toSpace

HeatingOutlet

563/8601/868

H

Floor toTop ofHeater

5713/16

611/8691/8

J

Floor toWaterConn.

257/16

297/16

311/2

K

Depth

111116

L

C/L ofWaterConn.

3/41

11/4

M

NPT

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Ultra Low NOx Atmospheric Vent High Input Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedRecovery efficiency up to 80%DIMENSIONS IN INCHES

page 30

page 31

Page 17: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

BH

C

J

A

G

E

D&M

F

L

BH

C

J

A

G

E

D&M

F

L

Photo ofURG2PV50H6N

Residential GasUltra Low NOx TTW® Power Vent Models

32/33

l ENERGY STAR® Qualified—Some modelsl Ultra Low NOx Burner with Primary and

Secondary Air Distribution Devicesl Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnosticsl Eco-Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.)

- Digital Thermal Sensor and Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Separate Immersed Thermowelll Powerful Blower Motor

- 10 ft. Power Cord Included (120 VAC)l Horizontal and Vertical Ventingl Hydrojet® Total Performance Systeml Vitraglas® Lining

l Non-CFC Foam Insulationl Water Connectionsl Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel All Models Comply with the Latest

Ultra Low NOx Requirement (10 ng/J NOx limit) except URG2PV75H6N (14 ng/J NOx limit)

40,00040,00040,00040,00056,00076,000

405040504875

URG1PV40S6N URG1PV50S6NH URG2PV40T6NH URG2PV50T6NH URG2PV50H6N URG2PV75H6N

7286728699N/A

571/4581/4667/8667/8663/8691/4

202220222226

40405/8497/8497/8497/8517/8

144169151176192270

113/4113/4113/4113/4113/4113/4

2 or 32 or 32 or 32 or 33 or 43 or 4

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor toVent

Conn.

1st HourRating(Gal.)

0.660.650.700.700.70N/A

EnergyFactor

434343436082

NatU.S.GPH

363636365068

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

471/8481/8565/8565/8565/8591/2

F

Floor toTop ofHeater

481/2491/258585861

G

Floor toWaterConn.

247/8267/8247/16

267/16

261/2301/4

H

Depth

88881111

J

C/L ofWaterConn.

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.

2" Vent Pipe

URG1PV40S6NURG1PV50S6NURG2PV40T6NURG2PV50T6N

3" Vent Pipe 3" Vent Pipe

URG2PV50H6NURG2PV75H6N

4" Vent Pipe

†50 ft.7 ft.45 ft.40 ft.35 ft.

123

Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows

†120 ft.15 ft.115 ft.110 ft.105 ft.

†50 ft.7 ft.

45 ft.40 ft.35 ft.

†180 ft.15 ft.

175 ft.170 ft.165 ft.

† For high altitude installations, consult the installation instructions.

Ultra Low NOx TTW® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 32

page 33

Page 18: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofURG2PDV50H6N

K

N

A

JF

EL

B

D & M

C

H

K

N

A

JF

EL

B

D & M

C

H

Residential GasUltra Low NOx Power Direct Vent Models

34/35

l ENERGY STAR® Qualifiedl Ultra Low NOx Burner with Primary and

Secondary Air Distribution Devicesl Eco-Defender Safety System®

- Maintenance-Free - Sight Window - Pedestal Basel Closed Combustion Venting Systeml Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Cast Aluminum Air Intake Bootl Hydrojet® Total Performance Systeml Vitraglas® Liningl Powerful Blower Model

- 10 ft. Power Cord Included (120 VAC)l Optional Concentric Vent Kit

Terminationl Horizontal and Vertical Venting

l 2" Non-CFC Foam Insulationl Water Connections— 3⁄4" NPT l 3/4" NPT Side Connections—

(URG2PDV50H6N only)l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valve

l Low Restriction Brass Drain Valvel Complies with the Latest Ultra Low NOx

Requirement (10 ng/J NOx limit)

40,00040,00050,000

405048

H URG2PDV40S6NH URG2PDV50S6NH URG2PDV50H6N

728692

591/2

601/2691/4

222422

423/8

43521/4

170196208

137/8137/8137/8

2 or 32 or 33 or 4

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor toExhaustOutlet

1st HourRating(Gal.)

0.700.700.68

EnergyFactor

434364

NatU.S.GPH

363645

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor toT&P

Conn.

E

Floor toGas

Conn.

493/4603/8691/4

F

Floor toTop ofHeater

593/8503/4583/4

H

Floor toAir

Intake

515260

J

Floor toWaterConn.

303/4323/432

K

Depth

——

153/4

L

Floor toSpaceHeatingReturn

——

521/4

M

Floor toSpaceHeatingSupply

101/2111/291/4

N

C/L Distance

From Intaketo Exhaust

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 10 year model, change suffix “6” to “10”. * Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.

INTAKE/COMBUSTION

AIR

RAINCAP

VENTEXHAUST

A

Concentric Vent Kit Termination

2" Kit

P/N 239-44069-02 29 1/4

A (in.)

3" Kit

P/N 239-44069-01 36 1/4

A (in.)

2" Vent Pipe

URG2PDV40S6NURG2PDV50S6N

35 ft.35 ft.7 ft.30 ft.25 ft.20 ft.

123

Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows

3" Vent Pipe

URG2PDV40S6NURG2PDV50S6N URG2PDV50H6N

85 ft.85 ft.7 ft.80 ft.75 ft.70 ft.

60 ft.60 ft.7 ft.

55 ft.50 ft.45 ft.

4" Vent Pipe

URG2PDV50H6N

100 ft.100 ft.7 ft.

95 ft.90 ft.85 ft.

Subtract 5ft. for each additional 90º elbow.

Ultra Low NOx Power Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 34

page 35

Page 19: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

J

H

F

E

B K K

AA

C C

L

D&M

Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View) Photo ofURG2DV50H6N

Residential GasUltra Low NOx Direct Vent Models

36/37

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System®

- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary

and Secondary Air Distribution Devicesl Closed Combustionl Reinforced Sealsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kitl Side Connections—3/4" NPT l 2" Non-CFC Foam Insulation

l Water Connections—3/4" NPT l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valve

l Low Restriction Brass Drain Valvel Design Certified by CSA International (formerly AGA

and CGA).l Complies with the Latest Ultra Low NOx

Requirement (10 ng/J NOx limit)

Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”. * Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

URG2DV40S6N / URG2DV50S6N Solid Vent Kit: Part No. 239-51283-00. Weight: 17 lbs.URG2DV40S6N / URG2DV50S6N Flexible Vent Kit: Part No. 239-51284-00. Weight: 11 lbs.URG2DV50H6N Solid Vent Kit: Part No. 239-51286-00. Weight: 22 lbs.URG2DV50H6N Flexible Vent Kit: Part No. 239-51287-00. Weight: 13 lbs.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.

URG2DV40S6N / URG2DV50S6N Optional Telescoping Solid Vent Kits: URG2DV50H6N Optional Telescoping Solid Vent Kits:Kit “A” Telescopes from 43⁄4" to 511⁄16" Part No. 239-41260-00 Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “B” Telescopes from 61⁄2" to 93⁄16" Part No. 239-41331-00 Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “C” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-41029-00 Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “D” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-41424-00 Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00

38,00038,00045,000

405048

URG2DV40S6NURG2DV50S6NURG2DV50H6N

738488

631/2 min.

721/2 min.

757/8 min.

222222

433/8521/4521/4

198221240

151515

334

556

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor to C/L of Vent

1st HourRating(Gal.)

0.620.600.60

EnergyFactor

414146

NatU.S.GPH

343438

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

I.D. O.D.

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

501/4591/4591/4

F

Floor toTop ofHeater

8811

H

C/L ofWaterConn.

511/2601/2601/8

J

Floor toWaterConn.

311/8311/8305/8

K

Depth

——

153/4

L

Floor toSpace

Heating Inlet

——

521/4

M

Floor toSpace

Heating Onlet

Approx.Shipping

Weight (lbs)

Ultra Low NOx Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 36

page 37

Page 20: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRTG-199HE-N

B A

C

D

OptionalIntake

Intake

J

L

M

K

5 /1 2" 5 /1 2"

G H

I

Exhaust

B A

C

D

OptionalIntake

Intake

J

L

M

K

5 /1 2" 5 /1 2"

G H

I

Exhaust

B A

C

D

OptionalIntake

Intake

J

L

M

K

5 /1 2" 5 /1 2"

G H

I

Exhaust

Residential GasInfiniti Tankless™ High Efficiency Models

38/39

l ENERGY STAR® Qualifiedl Featuring the SRT™ Scale Reduction Technology - Vertical Modulating Burner Design - Dual Fan Configuration - Internal Turbulators - Dual Heat Exchangerl Built-In Digital Controll Active Bypassl Cascading Kit (Optional)l Venting Flexibilityl Gas Connection Flexibility—1/2", 3/4", or 1"l Inlet Water Filterl Space Saving Installationl Built-In Freeze Protectionl Interior and Exterior Installation Capabilityl Complies with the Latest Ultra-Low NOx

Requirement (10 ng/J NOx limit)

19,900–199,000Indoor / Outdoor*H RTG-199HE-N 3 0.95 140º F0.5

VentConn.

Recovery90°F Rise*

GPM

4.2

InputBTU/Hr.Installation

ModelNumber

EF RatingNat.

MinimumWater Flow

GPM

MaximumTemperature

Setting

309/16H RTG-199HE-N 74

A

Height

1713/16

B

Width

107/16

C

Depth

53/16

D

Intake/Exhaust

Center Line

69/16

G

HotWaterOutlet

61/8

H

ColdWaterInlet

65/16

I

HotWaterOutlet

211/16

J

GasConn.

23/8

K

CondensateTee

25/8

L

CondensateTee

23/8

L

GasConn

ModelNumber

Approx.Shipping

Weight (lbs)

For Propane (LP) Models change suffix “N” to “X”. Requires an electrical power supply from a 120VAC 60Hz properly rated receptacle and must be properly grounded. Power supply cord provided. * Outdoor installation requires optional outdoor kitH = ENERGY STAR® Qualified.

2" Venting

Twin Pipe

9.5 ft.9.5 ft.19.0 ft.5.0 ft.2.5 ft.

1

Max. Allowable Exhaust Vent LengthMax. Allowable Intake Vent LengthCombined Max. Allowable VentElbow Equivalency 90ºElbow Equivalency 45ºNumber of 90° Elbows

3" Venting

Twin Pipe Concentric

31.0 ft.31.0 ft.62.0 ft.5.0 ft.2.5 ft.

5

23.0 ft.23.0 ft.46.0 ft.5.0 ft.2.5 ft.

4

Twin Pipe Concentric

63.0 ft.63.0 ft.126.0 ft.5.0 ft.2.5 ft.

7

43.0 ft.43.0 ft.83.0 ft.5.0 ft.2.5 ft.

7

4" Venting

Infiniti Tankless™ High Efficiency ModelsNATURAL GAS AND LIQUID PROPANE GAS MODELSDIMENSIONS IN INCHES

page 38

page 39

Page 21: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRTG-199ME-N

B A

C

J

L

M

K

G H

I

D

5 /1 2" 5 /1 2"

OptionalIntake

Intake Exhaust

Residential GasInfiniti Tankless™ Mid Efficiency Models

40/41

l Featuring the SRT™ Scale Reduction Technology

- Vertical Modulating Burner Design - Dual Fan Configuration - Internal Turbulators - Dual Heat Exchangerl Built-In Digital Controll Cascading Kit (Optional)l Gas Connection Flexibility—1/2", 3/4", or 1"l Inlet Water Filterl Space Saving Installationl Built-In Freeze Protectionl Interior and Exterior Installation Capabilityl Complies with the Latest Ultra-Low NOx

Requirement (10 ng/J NOx limit)

19,900–199,000Indoor / Outdoor*RTG-199ME-N 3 0.83 140º F0.5

VentConn.

Recovery90°F Rise*

GPM

3.7

InputBTU/Hr.Installation

ModelNumber

EF RatingNat.

MinimumWater Flow

GPM

MaximumTemperature

Setting

309/16RTG-199ME-N 67

A

Height

1713/16

B

Width

107/16

C

Depth

53/16

D

Intake/Exhaust

Center Line

69/16

G

HotWaterOutlet

61/8

H

ColdWaterInlet

65/16

I

HotWaterOutlet

211/16

J

GasConn.

23/8

K

CondensateTee

25/8

L

CondensateTee

23/8

L

GasConn

ModelNumber

Approx.Shipping

Weight (lbs)

For Propane (LP) Models change suffix “N” to “X”. Requires an electrical power supply from a 120VAC 60Hz properly rated receptacle and must be properly grounded. Power supply cord provided.* Outdoor installation requires optional outdoor kit

3" Venting

28.5 ft.28.5 ft.57.0 ft.5.0 ft.2.5 ft.

5

Max. Allowable Exhaust Vent LengthMax. Allowable Intake Vent LengthCombined Max. Allowable VentElbow Equivalency 90ºElbow Equivalency 45ºNumber of 90° Elbows

4" Venting

61.25 ft.61.25 ft.122.5 ft.5.0 ft.2.5 ft.

7

Infiniti Tankless™ Mid Efficiency ModelsNATURAL GAS AND LIQUID PROPANE GAS MODELSDIMENSIONS IN INCHES

page 40

page 41

Page 22: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Residential ElectricEnergy Saver Water Heaters

42/43

All models are ETL listed. All water connections are 3⁄4" NPT true dielectric fittings (RE120L). All electrical connections are 3⁄4". All models are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped with two installed heat traps (except Utility, Wall Hung models, and RE120L).Note: The Upright and Lowboy heaters will be wired single phase interlocking (non-simultaneous) 240 volt with 4500 watt elements, unless otherwise specified. Other wattages are available up to 6000 watts (208, 240, 277 and 480 volt). (Reference chart on following page for non-simultaneous and simultaneous limitations). 4500 watt/240 volt elements require a 25 amp or 30 amp circ uit breaker. For 120 volt (non-simultaneous), all models have a maximum wattage of 3000. (120 and 277 volt can only be wired single phase.)

Note: The Utility and Wall Hung Heaters will be wired for 120 volt with a 1500 watt element. The 1500 watt/120 volt element requires a 20 amp breaker. Other wattages are available. Maximum wattage for 6 and 12 gallon tall utility models is 3000W. Maximum wattage for 10, 12 and 15 gallon utility models is 6000W. Maximum wattage for the 6 gallon wall hung model is 3000W. Maximum wattage for 12, 20 and 30 gallon wall hung models is 6000W.

General

Incoloy Element Availability Chart

yesnonononononononono

120V

1500200025003000350040004500500055006000

Watts

yesyesyesyesyesyesyesyesyesyes

208V

yesyesyesyesyesyesyesyesyesyes

240V

noyesnoyesnoyesyesyesyesyes

277V

noyesnoyesnoyesyesyesyesyes

480V

VoltageWattage

Limitations forSimultaneous

Operation

1500W / 1500W2000W / 2000W2500W / 2500W3000W / 3000W3500W / 3500W4000W / 4000W4500W / 4500W5000W / 5000W5500W / 5500W6000W / 6000W

yesnonononononononono

120V

yesyesyesyesyesyesyesyesnono

208V

yesyesyesyesyesyesyesyesyesno

240V

yesyesyesyesnoyesyesyesnoyes

277V

yesyesyesyesnoyesyesyesnoyes

480V

VoltageWattage

Limitations forNon-Simultaneous

Operation

1500W / 1500W2000W / 2000W2500W / 2500W3000W / 3000W3500W / 3500W4000W / 4000W4500W / 4500W5000W / 5000W5500W / 5500W6000W / 6000W

WattageLimitations forSingle Element

Operation

1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W

yesyesyesyesnononononono

120V

yesyesyesyesyesyesyesyesyesyes

208V

yesyesyesyesyesyesyesyesyesyes

240V

yesyesyesyesnoyesyesyes

yes**yes

277V

yesyesyesyesnoyesyesyes

yes**yes

480V

DesignatorVoltage

A120

E277

H480

J600

L*208

C208/240

DesignatorWatt

J1000

K1250

L1500

M2000

N2500

P3000

R3500

S3800

T4000

W4500

X5000

Y5500

Z6000

Phase 13

Single PhaseThree Phase

Operation NS

Non-simultaneousSimultaneous

Designator240V Wattage208V Wattage

J1000—

K1250—

L15001000

M20001500

N25002000

P3000—

R35002500

S3800—

T40003000

W45003500

X5000—

Y55004000

Z60004500

X**—

5000

Y**—

5500†

Z**—

6000†

EX: RE3340T6-1NCWW

EX: RE3340T6-1NCWW

EX: RE3340T6-1NCWW

EX: RE3340T6-1NCWW, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of 3500W/3500W.* Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.† Available in non-simultaneous only.

EX: RE3340T6-1NCWW* Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.

For 120V, 277V, 480V, and 600V operation

For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)

** Incoloy® element only.

page 42

page 43

Page 23: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRE2H50R10B

AC

D

B

EF

Residential ElectricAeroTherm™ Series Heat Pump Models

44/45

l ENERGY STAR® Qualifiedl The AeroTherm™ Series Control

Panel - User-Friendly, Easy-to-Read

Display - LED’s Clearly Indicate the Current

Operating Mode - Display Communicates Current

Status, Mode and Set Point, and Displays Error Messages when Applicable

l Operating Modes Offer Flexibility - Heat Pump (Only) Mode - Hybrid Mode - Electric (Only) Mode - Vacation Model Quiet Operationl Can Be Laid Down for Easier

Transportationl Easily Accessible Top Mounted

Washable Air Filter

l Operating Air Temperature Range of 35-120°F for the Heat Pump

l Backup Electric Heating Elementsl Direct Heat Transfer with

Immersed Elementsl 2" Non-CFC Foam Insulationl Water Connections—3/4" NPTl Protective Magnesium Alloy

Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel Design Certified to NSF/ANSI 372

(Lead Content).l Northern Climate Tier 3 Capablel Optional Ducting Kit

6994

5080

RE2H50R10BRE2H80R10B

591/8711/8

213/425

88

195235

463/4583/4

603/4731/2

ELECTRIC MODELS Recovery90°F Rise*

A

Floor toHeater Top

3.393.26

EnergyFactor

2121

NatU.S.GPH

1818

NatImp.GPH

1st HourDelivery Rating

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor to Water Conn.

D

Distance Between

Water Conn.

E

Floor toCondensate

Conn.

383/4503/8

F

Floor toT&P

Heater

Approx.Shipping

Weight (lbs)

* Based on 4500/4000W, Non-Simultaneous Operation. Optional Ducting Kit: Part No. GVK8HS. Kit installation also requires 8" insulated flexible ducting, ducting support hangers, and exterior wall vents for inlet & outlet. Additional clearances required for ducting, refer to ducting kit instructions.

PARTS INCLUDED

Upper Inlet Duct Adapter

Lower Inlet Duct Adapter

Inlet Duct Filter

Outlet Duct Adapter

Drilling Screws (6)

8” Hose Clamps (2)

Assembly Screws (8)

AeroTherm™ Series Heat Pump ModelsC.E.C. ListedDIMENSIONS IN INCHES

page 44

page 45

Page 24: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRE250S6

B

8"

C

A

D

B

8"

C

A

D

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

Residential ElectricUpright Models

46/47

l Fully Automatic Controlsl Direct Heat Transfer with Immersed Elementsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPT l Heat Traps l Protective Magnesium Anode Rodl Simultaneous and Non-Simultaneous

Operation Availablel Voltages Available—120V, 208V, 240V,

277V, 480Vl Single Phase or Three Phase Operation

Available—120V & 277V l T&P Relief Valvel Design Evaluated by ETL in Accordance

with Part 280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency

47555667675567

30404050504050

RE330S6RE340S6RE340T6RE350S6RE350T6RE240S6†RE250S6†

47477/8605/847

585/84847

20222024222022

100114125144138123143

473/4485/8613/8473/4593/8483/4473/4

ELECTRIC MODELS Recovery90°F Rise*

A

Floor toHeater Top

0.950.950.950.950.950.950.95

EnergyFactor

21212121212121

NatU.S.GPH

18181818181818

NatImp.GPH

1st HourRating(Gal.)

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor to Water Conn.

473/4485/8613/8473/4593/8483/4473/4

D

Floor toT&P

Conn.

Approx.Shipping

Weight (lbs)

† Models include supplied insulation blanket (2" thick). Dimensions in charts above do not include blanket thickness. For 10 year models, change suffix “6” to “10”.* Based on 4500W/4500W, Non-Simultaneous operation. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Wattage Limitations for Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Wattage Limitations for Non-Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)

Upright ModelsC.E.C. ListedDIMENSIONS IN INCHES

page 46

page 47

Page 25: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRE240L6

B

8"

Anode(RE250L only)

OptionalTop T&PLocation

C

A

D

B

8"

Anode(RE250L only)

OptionalTop T&PLocation

C

A

D

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

Residential ElectricLowboy Models

48/49

l Models above 20-Gallon Meet or Exceed Efficiency Requirements

l Fully Automatic Controlsl Low Restriction Brass Drain

Valvel Direct Heat Transfer with

Immersed Elementsl Hydrojet® Total Performance

Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Trapsl Protective Magnesium

Anode Rodl Simultaneous and Non-

Simultaneous Operation Available

l Voltages Available—120V, 208V, 240V, 277V, 480V

l Single Phase or Three Phase Operation Available—120V & 277V

l T&P Relief Valve— Side T&P is standard. Optional top T&P location is available

l Design Evaluated by ETL in Accordance with Part 280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency

—455558

19283847

RE120L6†RE230L6**RE240L6**RE250L6**

247/8297/8325/8335/8

18222426

65129153173

255/8303/4331/2343/4

ELECTRIC MODELS Recovery90°F Rise*

A

Floor toHeater Top

—0.950.950.95

EnergyFactor

21212121

NatU.S.GPH

18181818

NatImp.GPH

1st HourRating(Gal.)

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor to Water Conn.

191/8 / 247/8241/8 / 305/8241/8 / 335/8241/2 / 345/8

D

Floor toT&P

Conn.††

Approx.Shipping

Weight (lbs)

Wattage Limitations for Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Wattage Limitations for Non-Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)

** Models include supplied insulation blanket (2” thick). Dimensions in charts above do not include blanket thickness.

For 10 year models, change suffix “6” to “10”.* Based on 4500W/4500W, Non-Simultaneous operation. All models available with optional top T&P location (plugged).† Exempt from ASHRAE 90.1b (current standard). Energy Factor and First Hour Rating are based on the

latest AHRI directory listings.†† All models feature side T&P location and must specify top T&P when ordering. “D” dimension listed as side/top.

Lowboy ModelsC.E.C. ListedDIMENSIONS IN INCHES

page 48

page 49

Page 26: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRE16UWV6

TOPVIEW

D

C

WALL

HOTOUTLET

COLDINLET

ELECTRICAL JUNCTION BOX

8"

FRONTVIEW

1213/16"D

HOT OUTLET3/4" CONN.

COLD INLET3/4" CONN.

HEATING ELEMENT & THERMOSTAT ACCESS

A A

E

3/4" RELIEF VALVE OPENING

SIDEVIEW

WALL

BB

BOTTOMVIEW

FRONT

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

Residential ElectricWall Hung Models

50/51

l Fully Automatic Controlsl Direct Heat Transfer With a Single

Immersed Elementl Vitraglas® Liningl 1" Non-CFC Foam Insulation

l Heavy Duty Wall Mounting Bracketl Water Connections—3/4" l Protective Magnesium Anode Rod

l Voltages Available—120V, 208V, 240V, 277V, 480V

l Single Phase Operation Onlyl T&P Relief Valve

61219

RE16WV6†RE112WV6RE120WV6

153/4163/8243/8

141818

375467

145/8185/8185/8

ELECTRIC MODELS Recovery90°F Rise*

A

Height

777

NatU.S.GPH

666

NatImp.GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Wall to Front

113/4123/4181/4

D

Height to Bracket

117/8121/221

E

Floor toT&P Heater

Approx.Shipping

Weight (lbs)

VoltageWattage Limitations 120V 208V 240V 277V 480V

RecoveryGPH Temperature Rise ºF

60 80 90 100 120Wattage

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

† Maximum wattage at any voltage is 3000W. For 10 year models, change suffix “6” to “10”. Single element only.* Based on 1500W operation.

Wall Hung ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 50

page 51

Page 27: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRE112U6

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

4" ALTERNATECOLD INLET(PLUGGED)6 &12 GAL.

ONLY

PLUG TYPEANODE6 &12

GAL. ONLY

ALTERNATE HOTOUTLET (PLUGGED)

6 &12 GAL. ONLY

8"

B

C D

F

E

G

A

10 & 15 Gallon Models

B

F

F

C

E

D

GA

6, 12 & 20 Gallon Models

Residential ElectricUtility Models

52/53

l Fully Automatic Controlsl Direct Heat Transfer with a Single Immersed Elementl Vitraglas® Liningl 1" Non-CFC Foam Insulationl Water Connections—3/4" NPTl Alternate Top Water Connectionsl Protective Magnesium Anode Rodl Voltages Available—120V, 208V, 240V, 277V, 480Vl Single Phase Operation Onlyl T&P Relief Valvel Design Evaluated by ETL in Accordance with Part

280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency

61012121519

RE16U6†RE110U6RE112U6RE112T6†RE115U6RE120U6

161/2171/2167/8273/4201/4243/4

141618141818

354453485865

101/815

101/4211/8173/4181/4

ELECTRIC MODELS Recovery90°F Rise*

A

Floor to Heater Top

777777

NatU.S.*GPH

666666

NatImp*GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor toHot Water

Conn.

101/814

101/4211/8163/4181/4

D

Floor toT&P

Conn.

31/8511/16

33

61/83

E

Floor toCold Water

Conn.

161/2911/16

161/2273/4101/8101/4

F

Floor toAnode Rod

161/212

167/8273/4

1211/16

243/4

G

Floor toElectrical

Access

Approx.Shipping

Weight (lbs)

VoltageWattage Limitations 120V 208V 240V 277V 480V

RecoveryGPH Temperature Rise ºF

60 80 90 100 120Wattage

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

† Maximum wattage at any voltage is 3000W. For 10 year models, change suffix “6” to “10”. Single element only.* Based on 1500W operation.

Utility ModelsC.E.C. ListedDIMENSIONS IN INCHES

page 52

page 53

Page 28: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofRE1-2U

B

A

C

B

A

C

Residential ElectricPowerful Compact® Model

54/55

l Compact Designl Fully Automatic Controll Direct Heat Transfer with Immersed Elementl Vitraglas® Liningl Non-CFC Insulationl Water Connections—3/4" NPTl Protective Magnesium Anode Rodl T&P Relief Valve OpeningOptional Features:l Wall Mounting Bracketl Aluminum Anode Rod

2RE1-2U6 121/4 97/8 13135/16

ELECTRIC MODELS Recovery90°F Rise*

A

Floor toHeater Top

7

NatU.S.GPH

6

NatImp.GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor to Water Conn.

Approx.Shipping

Weight (lbs)

Includes a 4ft. cord with 3 prong grounded plug (20 amp circuit required). For 10 year models, change suffix “6” to “10”. Single element only.* Based on 1500W operation. Only available as 120V / 1500W.

Copper Screw Type Immersion ElementSMALL FLANGEOF BRACKET

SMALL FLANGEOF BRACKET

Optional Wall Mounting Bracket

(2 brackets)Part Number

265-45018-00

Powerful Compact® ModelMeet or exceed ASHRAE 90.1b (current standard) CEC ListedDIMENSIONS IN INCHES

page 54

page 55

Page 29: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

THERMOSTATIC FLOWCONTROLLED

TWIN HEATINGMODULE

THERMOSTATICTHREE PHASE

SINGLE POINT

Residential Electric Specialty ProductsInstantaneous Water Heaters

56/57

l On Demand Hot Water—No delayl Cut Energy Waste—Flow switch activates heater only on

demand (no stand-by heat loss)l Continuous Hot Water—No storage capacity to run out l No T&P Relief Valve Needed—Check local codesl Integral Flow Restrictor—Built-in to ensure proper

temperature risel 10 Year Warranty on Heater Body/Element Assemblyl Easy Installation – Mounts on Wall – No Sweat

Connectionsl Ni Chrome Heating Element —A unique, patented flow

path ensures optimum heat transfer and extended element life

l Reduces Calcificationl Space Saving Installation—Compact sizel Field Serviceable Element —1 year warranty

3.03.53.54.14.15.5

ES-3000-1-S-10ES-3500-1-S-10ES-3500-4-S-10ES-4100-2-S-10ES-4100-5-S-10ES-5500-4-S-10

120120240208277240

41°48°48°56°56°75°

10 AWG10 AWG14 AWG12 AWG14 AWG10 AWG

Single Point Single Phase ModelsDIMENSIONS IN INCHES

ELECTRIC

Temp.Rise °F0.5 GPMVoltage

25.029.014.619.714.822.9

AMPSkW

RatingModel

Number*Recommended

Wire Size

7.59.5

EFT-7500-4-S-10EFT-9500-4-S-10

240240

34°43°

8 AWG8 AWG

Thermostatic Single Phase ModelsDIMENSIONS IN INCHES

ELECTRIC

Temp.Rise °F

1.5 GPM

25°32°

Temp.Rise °F

2.0 GPM

51°65°

Temp.Rise °F

1.0 GPM

68°86°

Temp.Rise °F

0.75 GPM

——

Temp.Rise °F

0.5 GPMVoltage

32.040.0

AMPSkW

RatingModel

Number*Recommended

Wire Size

SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials: Cover: ABS UL rated 94Vo. Glass Reinforced “Fortron®” Heater Body and Ni Chrome ElementColor: White • Element: Replaceable cartridge insert • Pipe-Fittings: 3/8" compression at top of unit

SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials: Cover: ABS UL rated 94Vo. Glass Reinforced “Fortron®” Heater Body and Ni Chrome ElementColor: White • Standard temperature range 100°F-140°F. • Element: Replaceable cartridge insert. • Pipe-Fittings: 1/2" compression at bottom of unit.U.L. Listed: E86887(M)

*Additional voltages and wattages are available. For more information, please consult factory.

Single Point Single Phase ModelsDIMENSIONS IN INCHES

Thermostatic Single Phase ModelsDIMENSIONS IN INCHES

page 56

page 57

Page 30: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

5.56.57.58.39.5

EFC-5500-4-S-10EFC-6500-4-S-10EFC-7500-4-S-10EFC-8300-2-S-10EFC-9500-4-S-10

240240240208240

25°30°34°38°43°

10 AWG10 AWG8 AWG8 AWG8 AWG

Flow Controlled Single Phase ModelsDIMENSIONS IN INCHES

ELECTRIC

Temp.Rise °F

1.5 GPM

18°22°25°29°32°

Temp.Rise °F

2.0 GPM

38°44°51°57°65°

Temp.Rise °F

1.0 GPM

50°59°68°76°86°

Temp.Rise °F

0.75 GPM

75°88°———

Temp.Rise °F

0.5 GPMVoltage

23.027.032.039.040.0

CurrentPer

PhasekW

RatingModel

Number*Recommended

Wire Size

SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials: Cover: ABS UL rated 94Vo. Glass Reinforced “Fortron®” Heater Body and Ni Chrome ElementColor: White • Standard temperature range 100°F-140°F. • Element: Replaceable cartridge insert. • Pipe-Fittings: 1/2" compression at bottom of unit.

19.0EFT-19000-4-D-10 240 43° 10 AWG

Series Two Single Phase Thermostatic ModelsDIMENSIONS IN INCHES

ELECTRIC

Temp.Rise °F

3.0 GPM

52°

Temp.Rise °F

2.5 GPM

65°

Temp.Rise °F

2.0 GPM

87°

Temp.Rise °F

1.5 GPMVoltage

2x40 Amps

CurrentPer

PhasekW

RatingModel

Number*Recommended

Wire Size

SpecificationsDimensions: 10" x 9" x 3"Weight: 8 lbs.Materials: Cover: Enameled Steel. Glass Reinforced “UDEL®” Heater Body and Ni Chrome ElementColor: White • Element: Dual replaceable cartridge inserts • Pipe-Fittings: 3/4" NPT at bottom of unit.U.S. Patent No.’s: 4,762,980 and 4,960,976

*Additional voltages and wattages are available. For more information, please consult factory.

Residential Electric Specialty ProductsInstantaneous Water Heaters (continued)

58/59

Flow Controlled Single Phase ModelsDIMENSIONS IN INCHES

Series Two Single Phase Thermostatic ModelsDIMENSIONS IN INCHES

18.024.032.0

EFTR-18000-6-T-10EFTR-24000-6-T-10EFTR-32000-6-T-10

480 Y**480 Y**480 Y**

41°54°73°

6 AWG6 AWG8 AWG

Series Three-Three Phase Thermostatic ModelsDIMENSIONS IN INCHES

ELECTRIC

Meet or exceed ASHRAE 90.1b (current standard) CEC ListedRecovery Efficiency ranging up to 78% (M-I-75 and M-I-100 have an 80% recovery efficiency.)

Temp.Rise °F

3.0 GPM

35°47°62°

Temp.Rise °F

3.5 GPM

32°41°55°

Temp.Rise °F

4.0 GPM

25°34°45°

Temp.Rise °F

5.0 GPM

49°65°87°

Temp.Rise °F

2.5 GPM

61°82°—

Temp.Rise °F

2.0 GPM

82°——

Temp.Rise °F

1.5 GPMVoltage

21.7 Amps28.9 Amps38.5 Amps

CurrentPer

PhasekW

RatingModel

Number*Recommended

Wire Size

28.038.0

EFT-28000-4-T-10EFT-38000-4-F-10

240240

65°86°

8 AWG Per Module8 AWG Per Module

Series Three-Single Phase Thermostatic ModelsDIMENSIONS IN INCHES

ELECTRIC

Temp.Rise °F

3.0 GPM

47°65°

Temp.Rise °F

4.0 GPM

76°104°

Temp.Rise °F

2.5 GPM

96°130°

Temp.Rise °F

2.0 GPM

——

Temp.Rise °F

1.5 GPMVoltage

3x40 Amps4x40 Amps

CurrentPer

PhasekW

RatingModel

Number*Recommended

Wire Size

SpecificationsSingle Phase Model Dimensions:12.25" x 15.25" x 4.25"Weight: 12 lbs.Three Phase Model Dimensions:12.125" x 20.1875" x 4.125"Weight: 15 lbs.Materials: Cover: Enameled Steel. Glass Reinforced “UDEL® “ Heater Body and Ni Chrome ElementColor: White • Element: Triple replaceable cartridge inserts • Pipe-Fittings: 3/4" NPT at bottom of unit.U.S. Patent No.’s: 4,762,980 and 4,960,976

VoltageCode Voltage

Voltage Identification CodeFor All Models

123456

120208220240277480

This unit must have 3 independent electrical circuits using correctly valued wire and 3 circuit breakers.

Example: EFT-28000-4-T-10The 4 in the model number indicates 240 volt.

* Additional voltages and wattages are available. For more information, please consult factory.** Neutral leg required.

Series Three-Single Phase Thermostatic ModelsDIMENSIONS IN INCHES

Series Three-Three Phase Thermostatic ModelsDIMENSIONS IN INCHES

page 58

page 59

Page 31: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

ANODES

A

C

BK

G

F

H

E J

D

Solar SensorWiringJunction Box

SolarThermistorWires,Gas ControlSensor

SolarThermistorWires

ANODES

A

C

BK

G

F

H

E J

D

Solar SensorWiringJunction Box

SolarThermistorWires,Gas ControlSensor

SolarThermistorWires

Photo ofS-DW2-504T6FBN

Residential SolarDouble-Wall Gas Backup Models

60/61

l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring

the patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Sensor Wires for Solar Thermistor

Connectionsl Hydrojet® Total Performance Systeml Vitraglas® Lining

l 3/4" NPT Female Connections on Front for Supply and Return

l 2" Non-CFC Foam Insulationl Potable Water Connections—

3⁄4" NPT true dielectric fittingsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve

(ASSE Approved)

65,00065,00076,000

456075

S-DW2-504T6FBNS-DW2-65T6FBNS-DW2-75S6BN

--

696982

591/463

623/8

222426

444

113/8113/8143/8

223264306

321/4321/4345/8

50531/252

NATURAL GAS MODELS A

Floorto FlueConn.

B

JacketDia.

GPHRecovery

90°F Rise*

1st HourDeliveryRating

InputBTU/Hr.

Gal.Cap.

ModelNumber

C

VentSize

D

Floorto T&PConn.

E

Floorto GasConn.

H

Floor toSolar Collector

Supply

101/8101/8121/2

J

Floor toSolar Collector

Return

5050

G

Floor toSpace Heating

Outlet

56591/259

F

Floorto Heater

Top

60631/4623/4

G

Floorto Water

Conn.

2628

303/8

K

Depth

Approx.Shipping

Weight (lbs)

Heat Exchanger Pressure Drop Curve

Flow Rate (GPM)

Pres

sure

Dro

p (P

SID

)

Hea

d Lo

ss (f

t. w

.c.)

16.00

14.00

12.00

10.00

8.00

6.00

4.00

2.00

0.00

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14

* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS

InputBTU/Hr.

GPH Rec.90°F Rise

S-DW2-504T6FSX 61,000 65S-DW2-65T6FSX 63,000 67S-DW2-75S6SX 76,000 82

EcoStor™ Double-Wall Gas Backup Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 60

page 61

Page 32: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

A

C

BK

G

F

H

E J

D

Solar SensorWiringJunction Box

SolarThermistorWires,Gas ControlSensor

SolarThermistorWires

A

C

BK

G

F

H

E J

D

Solar SensorWiringJunction Box

SolarThermistorWires,Gas ControlSensor

SolarThermistorWires

Photo ofS-DW2-TW-65T6FBN

Residential SolarEcoStor2™ TTW® Power Vent Double-Wall Gas Backup Models

62/63

l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Sensor Wires for Solar Thermistor

Connectionsl Horizontal and Vertical Ventingl High Efficiency Blower

- 10 ft. Power Cord Included (120 VAC)

l Hydrojet® Total Performance Systeml Vitraglas® Lining l Supply and Return Connections—

3⁄4" NPTl 2" Non-CFC Foam Insulationl Potable Water Connections—3⁄4" NPT true

dielectric fittingsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel S-DW2-TW-75 Is Not FVIR Compliantl Thermostatic Mixing Valve (ASSE Approved)

67,00070,00076,000

456070

S-DW2-TW-50T6FBNS-DW2-TW-65T6FBNS-DW2-TW-75T6BN

-727582

591/463

623/8

591/4222426

3 or 43 or 4

4

113/8113/8143/8

247281336

321/4321/4345/8

50531/252

NATURAL GAS MODELS A

Floorto FlueConn.

B

JacketDia.

GPHRecovery

90°F Rise*

1st HourDeliveryRating

InputBTU/Hr.

Gal.Cap.

ModelNumber

C

VentSize

D

Floorto T&PConn.

E

Floorto GasConn.

H

Floor toSolar Collector

Supply

101/8101/8121/2

J

Floor toSolar Collector

Return

5050

G

Floor toSpace Heating

Outlet

56591/259

F

Floorto Heater

Top

60631/4623/4

G

Floorto Water

Conn.

2628

303/8

K

Depth

Approx.Shipping

Weight (lbs)

Heat Exchanger Pressure Drop Curve

Flow Rate (GPM)

Pres

sure

Dro

p (P

SID

)

Hea

d Lo

ss (f

t. w

.c.)

16.00

14.00

12.00

10.00

8.00

6.00

4.00

2.00

0.00

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Subtract 5ft. for each additional 90° elbow.

** S-DW2-TW-75 Max. 3" vent length is 50ft.

3"Vent Pipe

4"Vent PipeS-DW2-TW-75T6BN

S-DW2-TW-65T6FBNS-DW2-TW-50T6FBN

60 ft.**7 ft.55 ft.50 ft.45 ft.

180 ft.15 ft.

175 ft.170 ft.165 ft.

Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3

* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”.

LP GAS MODELSInput

BTU/Hr.GPH Rec.90°F Rise

S-DW2-TW-50T6FSX 60,000 65S-DW2-TW-65T6FSX 63,000 68S-DW2-TW-75T6SX 75,500 81

EcoStor2™ TTW® Power Vent Double-Wall Gas Backup ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

80% Recovery EfficiencyDIMENSIONS IN INCHES

page 62

page 63

Page 33: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofS-2-65T6FBN

65 /75 Gallon Capacity 100 Gallon Capacity

K

H

K

A A

G G

F F

E EJ J

D D

H

B B

CC

Solar Thermistor Wiresand Gas Control SensorUnder Cover

AnodeAnodes

Hot WaterOutletCold WaterInlet

Hot WaterOutletCold WaterInletSolar Sensor

WiringJunction Box

Solar SensorWiringJunction Box

FromSolarCollector

Solar ThermistorWires and GasControl SensorUnder Cover

SolarThermistorWiresUnder Cover

SolarThermistorWiresUnder Cover

To SolarCollector

To SolarCollector

From SolarCollector

AnodeAnodes

Hot WaterOutletCold WaterInlet

Hot WaterOutletCold WaterInletSolar Sensor

WiringJunction Box

Solar SensorWiringJunction Box

Residential SolarEcoStor™ Open Loop Gas Backup Models

64/65

l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control

System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System®

featuring the patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Hydrojet® Total Performance

System

l Vitraglas® Lining l Supply and return

Connections—3⁄4" NPTl 2" Non-CFC Foam Insulationl Potable Water Connections—3⁄4"

NPT (65 gallon), 1" NPT (75 gallon) and 11⁄4" NPT (100 gallon) true dielectric fittings

l Protective Anode Rods—65 and 75 gallon models (1 Anode Rod), 100 gallon Model (2 Anode Rods)

l T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve

(ASSE Approved)

65,00076,00085,000

6575100

S-2-65T6FBNS-2-75S6BNS-2-100T6BN

-698292

63623/8

6311/16

591/42426

281/4

444

113/8141/8141/4

215250400

601/4593/4383/4

531/252

391/4

NATURAL GAS MODELS A

Floorto FlueConn.

B

JacketDia.

GPHRecovery

90°F Rise*

1st HourDeliveryRating

InputBTU/Hr.

Gal.Cap.

ModelNumber

C

VentSize

D

Floorto T&PConn.

E

Floorto GasConn.

H

Floor toSolar Collector

Supply

101/8121/2171/2

J

Floor toSolar Collector

Return

5050

G

Floor toSpace Heating

Outlet

591/259

651/2

F

Floorto Heater

Top

601/4593/4671/2

G

Floorto Water

Conn.

28303/8321/4

K

Depth

Approx.Shipping

Weight (lbs)

* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS

InputBTU/Hr.

GPH Rec.90°F Rise

S-2-65T6FSX 63,000 67S-2-75S6SX 76,000 82S-2-100T6SX 88,000 95

EcoStor™ Open Loop Gas Backup Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 64

page 65

Page 34: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

K

B

A

G

F

H

E J

D

B

SolarThermistorWiresand GasControl SensorUnder Cover

Anode Hot WaterOutletCold WaterInlet

From SolarCollector

From SolarCollector

SolarSensorWiringJunctionBox

SolarThermistorWiresUnder Cover

To SolarCollectorK

B

A

G

F

H

E J

D

B

SolarThermistorWiresand GasControl SensorUnder Cover

Anode Hot WaterOutletCold WaterInlet

From SolarCollector

From SolarCollector

SolarSensorWiringJunctionBox

SolarThermistorWiresUnder Cover

To SolarCollector

Photo ofS-2-TW65T6FBN

Residential SolarEcoStor™ TTW® Power Vent Open Loop Gas Backup Models

66/67

l 3/4" NPT Solar Collector Supply and Return Connections (No Internal Heat Exchanger)

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Flammable Vapor Sensor

- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Sensor Wires for Solar Thermistor

Connectionsl Horizontal and Vertical Ventingl High Efficiency Blower

- 10 ft. Power Cord Included (120 VAC)l Hydrojet® Total Performance System

l Vitraglas® Lining l Supply and Return Connections—3⁄4" NPTl 2" Non-CFC Foam Insulationl Potable Water Connections—

3⁄4" NPT true dielectric fittingsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE Approved)

70,00076,000

6575

S-2-TW65T6FBNS-2-TW75T6BN

-7582

63623/8

591/42426

33

113/8141/8

225260

321/4345/8

531/252

NATURAL GAS MODELS A

Floorto FlueConn.

B

JacketDia.

GPHRecovery

90°F Rise*

1st HourDeliveryRating

InputBTU/Hr.

Gal.Cap.

ModelNumber

C

VentSize

D

Floorto T&PConn.

E

Floorto GasConn.

H

Floor toSolar Collector

Supply

101/8121/2

J

Floor toSolar Collector

Return

5050

G

Floor toSpace Heating

Outlet

591/259

F

Floorto Heater

Top

601/4593/4

G

Floorto Water

Conn.

28303/8

K

Depth

Approx.Shipping

Weight (lbs)

* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. 120 V.A.C. required for power venting. 120 V.A.C. 60HZ 3.1 Amperes.

Subtract 5ft. for each additional 90° elbow.** S-2-TW-75 Max. 3" vent length is 50 ft. (15.24 m).

3"Vent Pipe

4"Vent PipeS-2-TW75T6BN

S-2-TW65T6FBN

60 ft.**7 ft.55 ft.50 ft.45 ft.

180 ft.15 ft.

175 ft.170 ft.165 ft.

Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3

LP GAS MODELSInput

BTU/Hr.GPH Rec.90°F Rise

S-2-TW65T6FSX 63,000 68S-2-TW75T6SX 75,500 81

EcoStor™ TTW® Power Vent Open Vent Gas Backup ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

80% Recovery EfficiencyDIMENSIONS IN INCHES

page 66

page 67

Page 35: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

ANODES

A

B

C

K

G

F

H

E J

D

Solar SensorWiringJunction Box

SolarThermistorWires,Gas ControlSensor

SolarThermistorWires

ANODES

A

B

C

K

G

F

H

E J

D

Solar SensorWiringJunction Box

SolarThermistorWires,Gas ControlSensor

SolarThermistorWires

Photo ofS-DW4-U5036FRN

Residential SolarEcoStor2™ SC Ultra Low NOx Double-Wall Gas Backup Models

68/69

l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design - Digital Thermal Sensor

- Maintenance-Free - Sight Window - Pedestal Basel Backup Ultra Low NOx Burnerl Sensor Wires for Solar Thermistor

Connectionsl Hydrojet® Total Performance Systeml Vitraglas® Lining l Supply and Return Connections—3⁄4" NPTl 2" Non-CFC Foam Insulation

l Potable Water Connections—3⁄4" NPT true dielectric fittings

l Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Complies with the Latest Ultra-Low NOx

Requirements (10/ngts NOx limit)l Thermostatic Mixing Valve (ASSE Approved)

40,00055,000

4560

S-DW4-U5036FRNS-DW2-U65T6FRN

-4357

591/463

591/42224

3 4

115/8115/8

233272

321/4321/4

50531/2

NATURAL GAS MODELS A

Floorto FlueConn.

B

JacketDia.

GPHRecovery

90°F Rise*

1st HourDeliveryRating

InputBTU/Hr.

Gal.Cap.

ModelNumber

C

VentSize

D

Floorto T&PConn.

E

Floorto GasConn.

H

Floor toSolar Collector

Supply

101/8101/8

J

Floor toSolar Collector

Return

5050

G

Floor toSpace Heating

Outlet

561/4591/2

F

Floorto Heater

Top

60631/4

G

Floorto Water

Conn.

2628

K

Depth

Approx.Shipping

Weight (lbs)

Heat Exchanger Pressure Drop Curve

Flow Rate (GPM)

Pres

sure

Dro

p (P

SID

)

Hea

d Lo

ss (f

t. w

.c.)

16.00

14.00

12.00

10.00

8.00

6.00

4.00

2.00

0.00

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14

* Based on manufacturer’s rated recovery efficiency. Complies with the latest ultra-low NOx requirement (10 ng/J NOx limit).

EcoStor2™ Ultra Low NOx Double-Wall Gas Backup ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

80% Recovery EfficiencyDIMENSIONS IN INCHES

page 68

page 69

Page 36: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofS-DC-DW2-55R6SW

CD

H

GF

E

A

B Solar Sensor Wiring Junction Box

Electric WiringJunction Box

SolarThermistorWiresandThermostat

SolarThermistorWiresandThermostat

CD

H

GF

E

A

B Solar Sensor Wiring Junction Box

Electric WiringJunction Box

SolarThermistorWiresandThermostat

SolarThermistorWiresandThermostat

Residential SolarEcoStor™ Dual Coil Heat Exchanger Backup Models

70/71

l Dual Coil Design—A single-wall heat exchanger is located in the upper portion of the tank. A double wall heat exchanger is located in the lower portion of the tank

l Applications—Dual heat exchangers located inside the tank may be connected to a variety of different heating systems

l Sensor Wires for Solar Thermistor Connections

l Hydrojet® Total Performance Systeml Vitraglas® Lining l Supply and Return Connections—1"

NPT upper coil, 3⁄4" NPT lower coil l 2" Non-CFC Foam Insulation

l Potable Water Connections—3⁄4" NPT true dielectric fittings extend water heater life and eases installation

l Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve

(ASSE Approved)

5570110

S-DC-DW2-55R6SWS-DC-DW2-70R6SWS-DC-DW2-110R6SW

591/4591/4621/2

2224

281/4

623/4623/466

5353

553/4

282313442

SOLAR MODELS C

Floor to Water Conn.

B

JacketDia.

A

Floor to Heater Top

Gal.Cap.

ModelNumber

D

Floor toT&P Conn.

371/2371/2391/4

F

Floor toUpper Coll.

Return

5656

573/4

E

Floor toUpper Coll.

Supply

53/853/853/8

H

Floor toLower Coll.

Return

271/2271/2271/2

G

Floor toLower Coll.

Supply

Approx.Shipping

Weight (lbs)

0.00

2.00

4.00

6.00

8.00

10.00

12.00

0.00

5.00

10.00

15.00

20.00

25.00

Single-wall (Upper Coil)

Double-wall (Lower Coil)

Heat Exchanger Pressure Drop Curve

Flow Rate (GPM)

Pres

sure

Dro

p (P

SI)

Hea

d Lo

ss (f

t. w

.c.)

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

EcoStor™ Dual Coil Heat Exchanger Backup ModelsDIMENSIONS IN INCHES

page 70

page 71

Page 37: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofS-SW2-60R6DS

CD

F

E

A

B

Solar SensorWiringJunction Box

Optional Outletfor Recirculation(S-SW2-60R& S-SW2-75R)

Solar ThermistorWires UpperHeating Elementwith Thermostat

Thermostat(controlslower element)

Solar ThermistorWires LowerHeating Element

CD

F

E

A

B

Solar SensorWiringJunction Box

Optional Outletfor Recirculation(S-SW2-60R& S-SW2-75R)

Solar ThermistorWires UpperHeating Elementwith Thermostat

Thermostat(controlslower element)

Solar ThermistorWires LowerHeating Element

Residential SolarEcoStor™ SC Single-Wall Electric Backup Models

72/73

l Heat Exchanger—Single-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Supplied Sensor Wires for Solar Thermistor Connections

l Integrated Mixing Devicel Element Backup—Single or dual

4500W heating elementsl Hydrojet® Total Performance Systeml Vitraglas® Lining l 1" NPT Female Connections on Front

for Supply and Returnl Potable Water Connections—3/4" NPT

true dielectric fittings l 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve

l Thermostatic Mixing Valve (ASSE Approved)

6075115

S-SW2-60R6DSS-SW2-75R6DSS-SW2-115R6DS

591/4591/4623/4

2224

281/4

631/4631/4663/4

5353

553/4

210236340

SOLAR MODELS C

Floor to Water Conn.

B

JacketDia.

A

Floor to Heater Top

Gal.Cap.

ModelNumber

D

Floor toT&P Conn.

291/2291/2291/2

E

Floor toSolar Coll.

Supply

73/873/873/8

F

Floor toSolar Coll.

Return

Approx.Shipping

Weight (lbs)

ModelNumber Single

ElementDual

Element

Electric Backup Water Heating Ratings

First Hour Supply (Gal.) StandbyHeat Loss

Rating(°F/Hr.)

S-SW2-60R6DSS-SW2-75R6DSS-SW2-115R6DS

465383

8497124

1.10.90.7

Heat Exchanger Pressure Drop Curve

Flow Rate (GPM)

Pres

sure

Dro

p (P

SID

)

Hea

d Lo

ss (f

t. w

.c.)

16.00

14.00

12.00

10.00

8.00

6.00

4.00

2.00

0.00

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14

For single element models change “D” to “S”.(Ex. S-SW2-60R6SS)

EcoStor™ Single-Wall Electric Backup ModelsDIMENSIONS IN INCHES

page 72

page 73

Page 38: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofS-DW2-60R6DS

CD

F

E

A

Solar SensorWiringJunction Box

Optional Outletfor Recirculation(S-DW2-60R& S-DW2-75R)

Solar ThermistorWires UpperHeating Elementwith Thermostat

Thermostat(controlslower elementon dualelement models)

Solar ThermistorWires LowerHeating Element(on dualelement models)

B

CD

F

E

A

Solar SensorWiringJunction Box

Optional Outletfor Recirculation(S-DW2-60R& S-DW2-75R)

Solar ThermistorWires UpperHeating Elementwith Thermostat

Thermostat(controlslower elementon dualelement models)

Solar ThermistorWires LowerHeating Element(on dualelement models)

B

Residential SolarEcoStor 2™ Double-Wall Electric Backup Models

74/75

l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Supplied Sensor Wires for Solar Thermistor Connections

l Element Backup—Single or dual 4500W heating elements - Optional 5500W

l Hydrojet® Total Performance Systeml Vitraglas® Lining l 3/4" NPT Female Connections on Front

for Supply and Returnl Potable Water Connections—

3/4" NPT true dielectric fittings l 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve

l Thermostatic Mixing Valve (ASSE Approved)

6075115

S-DW2-60R6DSS-DW2-75R6DSS-DW2-115R6DS

591/4591/4623/4

2224

281/4

631/4631/4663/4

5353

553/4

217241345

SOLAR MODELS C

Floor to Water Conn.

B

JacketDia.

A

Floor to Heater Top

Gal.Cap.

ModelNumber

D

Floor toT&P Conn.

291/2291/2291/2

E

Floor toSolar Coll.

Supply

73/873/873/8

F

Floor toSolar Coll.

Return

Approx.Shipping

Weight (lbs)

ModelNumber Single

ElementDual

Element

Electric Backup Water Heating Ratings

First Hour Supply (Gal.) StandbyHeat Loss

Rating(°F/Hr.)

S-DW2-60R6DSS-DW2-75R6DSS-DW2-115R6DS

465383

8497124

1.10.90.7

For single element models change “D” to “S”.(Ex. S-DW2-60R6SS)

Heat Exchanger Pressure Drop Curve

Flow Rate (GPM)

Pres

sure

Dro

p (P

SID

)

Hea

d Lo

ss (f

t. w

.c.)

16.00

14.00

12.00

10.00

8.00

6.00

4.00

2.00

0.00

7.00

6.00

5.00

4.00

3.00

2.00

1.00

0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14

EcoStor2™ Double-Wall Electric Backup ModelsDIMENSIONS IN INCHES

page 74

page 75

Page 39: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

B

A

C

ED

F

4

1

3

2

8"8"

#1 - 3/4" Pump Suction#2 - 3/4" Cold Inlet#3 - 3/4" Collector Return#4 - 3/4" Hot Outlet

Photo of MS80R6SS

Residential SolarSolar Saver® Electric Backup Models

76/77

l Vitraglas® Liningl Hydrojet® Total Performance Systeml Equipped with a 4500 watt Element And Automatic

Thermostat—Where a backup system is desired. If storage only is desired do not connect the unit to the electrical service.

l Top of Tank Access for Wiring and Water Connectionsl Pre-Wired Sensor Leadl Thermal Feetl Water Connections—3/4" NPT true dielectric fittings l 2" Non-CFC foam insulationl Protective Magnesium Anode Rodl Consult Factory for Other Wattagesl T&P Relief Valvel Low Restriction Brass Drain Valve

6580119

MS65R6SSMS80R6SS†MS120R6SS†

5959

621/2

222428

6060

631/2

521/2521/256

168210310

SOLAR MODELS C

Floor to Water Conn.

B

JacketDia.

A

Floor to Heater Top

Gal.Cap.

ModelNumber

D

Floor toT&P Conn.

—38

381/4

E

Fl. to Alt.Coll. Return

Conn.

—77/877/8

F

Fl. to Alt.Coll. Supply

Conn.

Approx.Shipping

Weight (lbs)

NOTE: Suffix letter “S” denotes single element and surface mounted thermostat. If requirements are for storage only, do not use element connections. Second suffix letter “S” denotes Screw-Type Element. Meets California Energy Commission requirements.† Models offer additional pump suction and collector return connections.

Solar Saver® Electric Backup ModelsMeet or exceed ASHRAE 90.1b (current standard)DIMENSIONS IN INCHES

page 76

page 77

Page 40: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofC-SW2-504T10FBN

K

C

AJ

H

E

F

D & G

B

PLUG TYPEANODE

K

C

AJ

H

E

F

D & G

B

PLUG TYPEANODE

Residential GasCombi1™ Single-Wall Atmospheric Models

78/79

l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal BaseAll Combi1™ Models Feature:l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature

Control System - Intelligent Diagnostics - Separate Immersed

Thermowelll Heat Exchanger—Single-wall 11⁄2"

O.D. enamel coated (Vitraglas®) Steel Coil

l Provides Domestic Hot Water and Space Heating in One System

l Low Heat Exchanger Head Loss —Up to 10 GPM flow, with less than 0.80 ft. of Head Loss

l Vitraglas® Liningl Hydrojet® Total Performance

Systeml Water Connections – 3/4" NPT

true dielectric fittings l 1" Front NPT Supply and Return

Connectionsl 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass

Drain Valvel Thermostatic Mixing Valve

(ASSE Approved)

65,00076,000

4572

C-SW2-504T10FBNC-SW2-75T10BN 92

112124

535863

591/4

621/4

2226 583/4

6259

50513/4

236292 521/4

5652

151/4151/4151/4

NATURAL GAS MODELS A

Floor toFlue

Conn.

13137/8

E

Floor toGas

Conn.

311/2295/8

F

Floor toExchanger

Inlet

563/859

H

Floor toTop ofHeater

603/863

J

Floor toTop Water

Conn.

241/2303/8

K

Depth

50513/4

G

Floor toExchanger

Outlet

B

JacketDia. GPH

Recovery90°F Rise*

1st Hour**DeliveryRating

InputBTU/Hr.

7081

GPHRecovery

90°F Rise*Gal.Cap.

ModelNumber

C

Height toTop ofHeater

D

Height toGas

Conn.

153/4153/4161/2

G

SpaceHeatingReturn

D

Floor toT&P

Conn.

F

SpaceHeatingOutlet4

4

C

VentSize

Approx.Shipping

Weight (lbs)

Heat Exchanger Head Loss

GPMFeet of Head Loss

20.03

50.20

80.51

100.80

121.15

All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. CAEF is .55 and CAAFLUE % is 80.0.

Heat Exchanger Values*

Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output

140°F120°F20°F

4.1 GPM35,500 BTU/Hr.

120°F100°F20°F

4.6 GPM39,500 BTU/Hr.

100°F80°F20°F

4.6 GPM39,500 BTU/Hr.

120°F100°F20°F

5.6 GPM47,500 BTU/Hr.

100°F80°F20°F

5.6 GPM47,500 BTU/Hr.

C-SW2-504TC-SW2-75T C-SW2-504T C-SW2-75T

* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.

LP GAS MODELSInput

BTU/Hr.GPH Rec.90°F Rise

C-SW2-504T10FSX 61,000 66C-SW2-75T10SX 76,000 81

Combi1™ Atmospheric Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 78

page 79

Page 41: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofC-SW2-TW50T10FBN

K B

C

A

J

H

E

F

D & GK B

C

A

J

H

E

F

D & G

Residential GasCombi1™ TTW® Single-Wall Power Vent Models

80/81

l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal BaseAll Combi1™ TTW® Models Feature:l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Heat Exchanger—Single-wall 11⁄2" O.D. enamel

coated (Vitraglas®) steell Provides Domestic Hot Water and Space Heating

in One Systeml Low Heat Exchanger Head Loss—Up to 10 GPM

flow, with less than 0.80 ft. of Head Lossl Vitraglas® Lining

l Power Vented - 10 ft. Power Cord Included (120 VAC)

l Hydrojet® Total Performance Systeml Horizontal and Vertical Ventingl Water Connections—3/4" NPT true dielectric

fittings l 1" NPT Front Supply and Return Connectionsl 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction

Brass Drain Valvel Thermostatic

Mixing Valve (ASSE Approved)

67,00076,000

4572

C-SW2-TW50T10FBNC-SW2-TW75T10BN 92

112124

535863

657/8

683/8

2226 583/4

6259

501/8

53243313 521/4

5652

151/4151/4151/4

NATURAL GAS MODELS A

Floor toVent

Conn.

113/4

15

E

Floor toGas

Conn.

311/2

341/2

F

Floor toExchanger

Inlet

563/8

601/4

H

Floor toTop ofHeater

603/4

641/4

J

Floor toTop Water

Conn.

263/4

31

K

Depth

50

53

G

Floor toExchanger

Outlet

B

JacketDia. GPH

Recovery90°F Rise*

1st Hour**DeliveryRating

InputBTU/Hr.

Gal.Cap.

7282

GPHRecovery

90°F Rise*Model

Number

C

Height toTop ofHeater

D

Height toGas

Conn.

153/4153/4161/2

G

SpaceHeatingReturn

D

Floor toT&P

Conn.

F

SpaceHeatingOutlet3 or 4

3 or 4

C

VentSize

Approx.Shipping

Weight (lbs)

All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. 120 V.A.C Required for Power Venting / 120 V.A.C., 60HZ, 3.1 Amperes.

Heat ExchangerHead Loss

GPM

2581012

Ft. ofHd. Loss

0.030.200.510.801.15

3"Vent Pipe

4"Vent Pipe

C-SW2-TW50C-SW2-TW75

60 ft.** 7 ft.55 ft.50 ft.45 ft.

180 ft. 15 ft.175 ft.170 ft.165 ft.

Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3

Subtract 5ft. for each additional 90° elbow.** C-SW2-TW75 maximum 3" vent length is 50ft.

Heat Exchanger Values*

Supply TemperatureReturn TemperatureDifferentialFlow Rate (TW50)Net Output (TW50)Flow Rate (TW75)Net Output (TW75)

140°F120°F20°F

4.1 GPM35,000 BTU/Hr.

4.1 GPM35,000 BTU/Hr.

120°F100°F20°F

4.6 GPM39,500 BTU/Hr.

5.6 GPM47,500 BTU/Hr.

100°F80°F20°F

4.6 GPM39,500 BTU/Hr.

5.6 GPM47,500 BTU/Hr.

* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.

LP GAS MODELSInput

BTU/Hr.GPH Rec.90°F Rise

C-SW2-TW50T10FSX 60,000 65C-SW2-TW75T10SX 75,500 81

Combi1™ TTW® Single-Wall Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 80

page 81

Page 42: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofC-DW2-504T10FBN

K

C

AJ

H

E

F

D & G

B

K

C

AJ

H

E

F

D & G

B

Residential GasCombi2™ Double-Wall Atmospheric Models

82/83

l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal BaseAll Combi2™ Models Feature:l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Heat Exchanger—Double-wall 11⁄2" O.D. enamel

coated (Vitraglas®) steel coil ensures separation of potable water and heating fluid

l Provides Domestic Hot Water and Space Heating in One System

l Low Heat Exchanger Head Loss—Up to 10 GPM flow, with less than 3.75 ft. of Head Loss

l Vitraglas® Lining

l Hydrojet® Total Performance Systeml Water Connections—3/4" NPT true dielectric

fittings l 3/4" Front NPT Supply and Return Connectionsl 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve

(ASSE Approved)

65,00076,000

4572

C-DW2-504T10FBNC-DW2-75T10BN 92

112124

535863

59 1/4

621/4

2226 583/4

6259

50513/4

238302 521/4

5652

151/4151/4151/4

NATURAL GAS MODELS A

Floor toFlue

Conn.

13137/8

E

Floor toGas

Conn.

27 7/8

295/8

F

Floor toExchanger

Inlet

56 3/859

H

Floor toTop ofHeater

60 3/863

J

Floor toTop Water

Conn.

241/2303/8

K

Depth

50513/4

G

Floor toExchanger

Outlet

B

JacketDia. GPH

Recovery90°F Rise*

1st Hour**DeliveryRating

InputBTU/Hr.

7081

GPHRecovery

90°F Rise*Gal.Cap.

ModelNumber

C

Height toTop ofHeater

D

Height toGas

Conn.

153/4153/4161/2

G

SpaceHeatingReturn

D

Floor toT&P

Conn.

F

SpaceHeatingOutlet4

4

C

VentSize

Approx.Shipping

Weight (lbs)

Heat Exchanger Head Loss

GPMFeet of Head Loss

20.15

50.94

82.40

103.75

125.40

All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. CAEF is .55 and CAAFLUE % is 80.0.

Heat Exchanger Values*

Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output

140°F120°F20°F

2.3 GPM20,000 BTU/Hr.

120°F100°F20°F

3.4 GPM29,000 BTU/Hr.

100°F80°F20°F

4.4 GPM38,000 BTU/Hr.

* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.

LP GAS MODELSInput

BTU/Hr.GPH Rec.90°F Rise

C-DW2-504T10FSX 61,000 66C-DW2-75T10SX 76,000 81

Combi2™ Double-Wall Atmospheric Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 82

page 83

Page 43: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofC-DW2-TW50T10FBN

K B

C

A

J

H

E

F

D & G

K B

C

A

J

H

E

F

D & G

Residential GasCombi2™ TTW® Double-Wall Power Vent Models

84/85

l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal BaseAll Combi2™ TTW® Models Feature:l Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Heat Exchanger—Double-wall 11⁄2" O.D. enamel

coated (Vitraglas®) steel coil ensures separation of potable water and heating fluid

l Provides Domestic Hot Water and Hydronic Heating in One System

l Low Heat Exchanger Head Loss—Up to 10 GPM flow, with less than 3.75 ft. of Head Loss

l Vitraglas® Liningl Hydrojet® Total Performance System

l Power Vented - 10 ft. Power Cord Included (120 VAC)

l Horizontal and Vertical Ventingl Water Connections—3/4" NPT

true dielectric fittings l 3/4" Front Supply and Return Connectionsl 2" Non-CFC Foam Insulationl Two protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE Approved)

67,00076,000

4572

C-DW2-TW50T10FBNC-DW2-TW75T10BN 92

112124

535863

657/8

683/82226 583/4

6259

501/8

53245315 521/4

5652

151/4151/4151/4

NATURAL GAS MODELS A

Floor toVent

Conn.

113/4

15

E

Floor toGas

Conn.

28

307/8

F

Floor toExchanger

Inlet

563/8

601/4

H

Floor toTop ofHeater

603/4

641/4

J

Floor toTop Water

Conn.

263/4

31

K

Depth

501/8

53

G

Floor toExchanger

Outlet

B

JacketDia. GPH

Recovery90°F Rise*

1st Hour**DeliveryRating

InputBTU/Hr.

Gal.Cap.

7282

GPHRecovery

90°F Rise*Model

Number

C

Height toTop ofHeater

D

Height toGas

Conn.

153/4153/4161/2

G

SpaceHeatingReturn

D

Floor toT&P

Conn.

F

SpaceHeatingOutlet3 or 4

3 or 4

C

VentSize

Approx.Shipping

Weight (lbs)

All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. 120 V.A.C Required for Power Venting / 120 V.A.C., 60HZ, 3.1 Amperes.

Heat ExchangerHead Loss

GPM

2581012

Ft. ofHd. Loss

0.150.942.403.755.40

3"Vent Pipe

4"Vent Pipe

C-DW2-TW50C-DW2-TW75

60 ft.** 7 ft.55 ft.50 ft.45 ft.

180 ft. 15 ft.175 ft.170 ft.165 ft.

Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3

Subtract 5ft. for each additional 90° elbow.** C-DW2-TW75 maximum 3" vent length is 50ft.

Heat Exchanger Values*

Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output

140°F120°F20°F

2.3 GPM20,000 BTU/Hr.

120°F100°F20°F

3.4 GPM29,000 BTU/Hr.

100°F80°F20°F

4.4 GPM38,000 BTU/Hr.

* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.

LP GAS MODELSInput

BTU/Hr.GPH Rec.90°F Rise

C-DW2-TW50T10FSX 60,000 65C-DW2-TW75T10SX 75,500 81

Combi2™ TTW® Double-Wall Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedRecovery Efficiency ranging up to 80% (Minimum)DIMENSIONS IN INCHES

page 84

page 85

Page 44: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo of SW-2-65-L

SW-2-30-L

SW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L

DA F

EG

C

B

D DA

F

F

E EG G

C C

B

A

B

POTABLECONNECTIONS

ANODE RODS(TYPICAL)

(TYPICAL)ANODE RODS

(TYPICAL)

POTABLECONNECTIONS

(TYPICAL)

ResidentialPowerStor Series® Single-Wall Indirect Models

86/87

l Heat Exchanger—Single-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Vitraglas® Liningl Hydrojet® Total Performance

Systeml Water Connections—3/4" NPT true

dielectric fittings (SW-2-120L has 1" NPT water connection)

l 1" NPT Connection for Boiler Supply And Return

l 2" Non-CFC Foam Insulationl Immersion Type Aquastat—

Accurate temperature controll Three Protective Aluminum

Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve

l Limited Lifetime Tank and Heat Exchanger Warranty

l AHRI Certifiedl Standby Heat Loss Is Less than

1/2 °F per Hour (ASHRAE 90.1b Current Standard)

32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000

3038486075116

SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L

2222222224

281/4

335/8411/8461/4591/459

621/2

59 1/8483/858

59 3/850

603/459 5/8493/4581/2603/4633/46811/16

281/4343/8401/8531/8527/8553/4

343/8417/84760

593/4631/4

164185195225250370

271/2271/2271/2271/2271/2281/2

A

Floorto FlueConn.

C

Floor toT&P

Conn.

A

Floor toHeater

Top

B

JacketDia.

InputBTU/Hr.

GallonCapacity

ModelNumber

D

Floor toWaterConn.

53/853/853/853/853/863/8

E

Floor toExchanger

Outlet

F

Floor toExchanger

Inlet

111/2111/2111/2111/2111/2111/2

G

Floor to Aquastat

Approx.Shipping

Weight (lbs)

ModelNumber 140°F 115°F

DOE Water Heater Performance

SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L

140°F 115°F

Maximum FirstHour Rating

(Gal.) @

279288297306321357

429438447456470507

140°F 115°F4.24.24.24.24.24.2

6.76.76.76.76.76.7

ContinuousDraw Rating

(Gal./Min.) @

Approximate BoilerOutput Needed

For Ratings(BTU/Hr.)

ApproximateBoiler OutputNeeded for

Ratings (BTU/Hr.)220,000220,000220,000220,000220,000220,000

55,00055,00055,00055,000

ModelNumber

AHRI Water Heater Ratings

SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L

140°F 115°FFirst HourDelivery

255260265275295325

ContinuousDraw Rating

@ 135°F(Gal./Hr.)

Approximate BoilerOutput Needed

For Ratings(BTU/Hr.)

235235235235235235

StandbyHeat Loss

Rating(°F/Hr.)

1.21.10.90.70.60.4

HeatSource

Flow Rate(Gal./Min.)

13.713.713.713.713.713.7

HeatReq.Rate

(BTU/Hr.)157,000157,000157,000157,000157,000157,000

55,00055,00055,00055,000

Note: These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180° F boiler water supply temperature. Other results will be obtained under different conditions.

Note: Based on 200° F boiler water temperature and 50°F potable water inlet temperature.

PowerStor Series® Single-Wall Indirect ModelsDIMENSIONS IN INCHES

page 86

page 87

Page 45: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofDW-2-50-L

B

D A

F

E

C

G

POTABLE WATER FITTINGS - 3/4" NPTANODES

COLDWATERINLET

HOTWATERINLET

TEMPERATUREANDPRESSURERELIEF VALVE

FROM BOILERSUPPLY3/4" NPT

TO BOILERRETURN3/4" NPT

DRAIN COUPLING3/4" NPT

SURFACEMOUNTEDTHERMOSTAT

B

D A

F

E

C

G

POTABLE WATER FITTINGS - 3/4" NPTANODES

COLDWATERINLET

HOTWATERINLET

TEMPERATUREANDPRESSURERELIEF VALVE

FROM BOILERSUPPLY3/4" NPT

TO BOILERRETURN3/4" NPT

DRAIN COUPLING3/4" NPT

SURFACEMOUNTEDTHERMOSTAT

l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Head Loss—Less than 5 ft. of Head Loss with flows up to 10 GPM

l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—3/4" NPT true

dielectric fittingsl 2" Non-CFC Foam Insulationl Surface-Mount Thermostatl Two Protective Magnesium Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Limited Lifetime Warranty on Tank

and Heat Exchangerl AHRI Certified

l Standard Heat Loss—Less than 1/2 °F per Hour (ASHRAE 90.1b Current Standard)

ResidentialPowerStor2™ Series® Double-Wall Indirect Models

88/89

41461/45959

38486475

DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L

22222224

343/8401/8531/8527/8

417/8471/460

593/4

53/853/853/853/8

111/2111/2111/2111/2

195205235255

D

Floor to WaterConn.

E

Floor toBoilerReturn

271/2271/2271/2271/2

F

Floor toBoilerSupply

C

Floor to T&P

Conn.

B

JacketDia.

A

Floor to Heater

TopGallon

Capacity

ModelNumber

G

Floor toThermostat

Approx.Shipping

Weight (lbs)11/2 (F&R)

11/2 (F)2 (R)

11/2 (T&F)2 (R)

ModelNumber

AHRI Water Heater Ratings

DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L

First HourDelivery

123133148158

ContinuousDraw Rating

@ 135°F(Gal./Hr.)

98989898

StandbyHeat Loss

Rating(°F/Hr.)

1.10.90.70.6

MinimumHeat Req.

Rate(BTU/Hr.)

65,00065,00065,00065,000

MinimumHeat SourceFlow Rate(Gal./Min.)

8.08.08.08.0

ModelNumber

DOE Water Heater Performance

DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L

140°F 115°F

Maximum FirstHour Rating

(Gal.) @

808796106

122129138148

140°F 115°F

ContinuousDraw Rating

(Gal./Min.) @

Approximate BoilerOutput Needed

For Ratings(BTU/Hr.)

0.90.90.90.9

1.61.61.61.6

55,00055,00055,00055,000

Note: These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180° F boiler water supply temperature. Other results will be obtained under different conditions.

Note: Based on 200° F boiler water temperature and 50°F potable water inlet temperature.

PowerStor2™ Series® Double-Wall Indirect ModelsDIMENSIONS IN INCHES

page 88

page 89

Page 46: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo of RTV-40-L

EF

H

CD A

G

OUTLET

T&P

B

E L

K H

17"*

C

F

GG 413/4"*

D

A

B

RTV-40-L RTV-52-L RTV-75-L

RTV-120-L*Floor to Top Spare 3/4” NPT

Tank Connection is 413⁄4”Floor to Bottom Spare 3/4” NPT

Tank Connection is 17”

1 2

1

2

ResidentialPowerStor Series® SS Stainless Steel Single-Wall Indirect Models

90/91

l Stainless Steel Heat Exchanger—Single-wall 1" O.D. stainless steel coil

l Stainless Steel Tank and Heat Exchanger—Made from Chromium Molybdenum - Titanium Ferritic 444 Stainless Steel Alloy

l Immersed Adjustable Honeywell Aquastat—Fast acting immersion aquastat for automatic temperature control

l Supply and Return Connections—3⁄4" NPT female connections are located on the front for both the Boiler Supply and Boiler Return (1" NPT on RTV-119)

l 2" Non-CFC Foam Insulation

l Potable Water Connections—3/4" NPT dielectric fittings extend water heater life and eases installation (11⁄4"w NPT on RTV-119)

l T&P Relief Valvel Low Restriction Brass Drain Valvel AHRI Certified

242424

301/4

351/4455/8637/8605/8

RTV-40-LRTV-52-LRTV-75-LRTV-120-L

555

111/4

91/291/291/2177/8

245/8283/8281/4451/2

8393117315

363/4463/8641/8641/8481/2

G

Floor toExchanger

Inlet

———

423/4

K

Floor toSpare 3/4" HotWater Conn.

———

177/8

L

Floor toSpare 3/4" Cold

Water Conn.

F

Floor toExchanger

Outlet

E

Floor toCold Water

Conn.

351/2457/8641/861

C

Floor toT&P

Conn.

B

JacketDia.

A

Floor toHeater

Top

405275119

Gal.Cap.

ModelNumber

F

Floor toWaterConn.

351/2457/8641/8491/2

D

Floor toHot Water

Conn.

19191936

H

Floor toAquastat

Approx.ShippingWeight

Notes:1) Inlet water temperature based on 50°F.2) RTV-119 supplied with 2 extra plugged tappings (see manual). Height to top spare plug is 413⁄4". Height to bottom spare plug is 17".3) RTV-119 equipped with steel casing.All potable water connections are 3/4” NPT (11⁄4" on RTV-119).3⁄4" Aquastat tapping.3⁄4" T&P valve tapping.

158200225360

RTV-40-LRTV-52-LRTV-75-LRTV-120-L

AHRI Water Heater Ratings

First HourDelivery

133165165280

ContinuousDraw

@ 135°F(Gal./Hr.)

0.90.70.50.6

StandbyHeat Loss

Rating(°F/Hr.)

88,000113,000113,000195,000

Min. HeatRequired

Rate(BTU/Hr.)

8.08.08.011.0

Min. HeatSource

Flow Rate(Gal./Min.)

ModelNumber

Note: These certified ratings were obtained with a heat output rate and flow rate as specified and a 180°F boiler water supply temperature. Other results will be obtained under different conditions.

PowerStor Series® SS Stainless Steel Single-Wall Indirect ModelsDIMENSIONS IN INCHES

page 90

page 91

Page 47: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofAST-50-6

TOP CONNECTIONS

DRAIN/BOILER RETURN

T&P(NOTPROVIDED)

BOILERSUPPLY

OUTLET

B

A C

D

ETOP CONNECTIONS

DRAIN/BOILER RETURN

T&P(NOTPROVIDED)

BOILERSUPPLY

OUTLET

B

A C

D

E

ResidentialStorage Tank Models

92/93

l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—3/4" NPT true dielectric fittings

(AST-120 has 1" NPT Connections) l 2" Non-CFC Foam Insulationl Fully Automatic Controlsl Protective Magnesium Anode Rodl Boiler Return Is 3/4"l Thermal Feetl T&P Relief Valve Openingl Brass Drain/Return Valve (3/4")

32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000

405080119

AST-40-6AST-50-6AST-80-6AST-120-6

467/8465/16

587/8627/8

202224

281/4

59 1/8483/858

59 3/850

603/459 5/8493/4581/2603/4633/46811/16

477/8475/16

597/8637/8

31/16

31/16

31/16

31/16

103130183305

A

Floorto FlueConn.

C

Floor to Top Water Conn.

B

JacketDia.

A

Floor toHeater Top Input

BTU/Hr.

GallonCapacity

ModelNumber

D

Floor to Drain/Boiler Return

3/43/43/41

E

Outlet3/43/43/41

F

Heat SourceSupply

3/43/43/43/4

G

Heat SourceReturn

Approx.ShippingWeight (lbs)

Note: Circulator pump and temperature pressure relief valve are NOT included. We recommend you use a stainless steel or low lead circulator pump and relief valve of your choice when installing these storage tanks.

Storage Tank ModelsDIMENSIONS IN INCHES

page 92

page 93

Page 48: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

The Bradford White MAGNUM Series® 94/95

If you’re selecting the water heating equipment for an apartment complex, restaurant, laundromat, hotel, school, manufacturing plant or any other business with a constant high demand for hot water, the Bradford White Magnum Series of commercial water heaters can fill all your requirements. Bradford White offers an extensive and comprehensive selection of water heating products for commercial applications. Our commercial and industrial models, known as the MAGNUM Series, include gas and electric light-duty versions, a full complement of high input Energy Saver units, Ultra High Efficiency unit (eF Seriesi), instantaneous models, booster units and storage tanks. Each and every one is designed and built to the most exacting quality specifications for durability, energy-efficiency and top performance.

Big Solution for Big DemandsBradford White commercial water heaters provide durability, energy efficiency, and exceptional performance you can rely on.

RightSpec® commercial sizing and specifying guide offers many unique features and upgrades. You’ll find it easy to use with complete specifications on the entire Residential and Magnum series line of commercial water heaters. The program enables you to determine the correct commercial model for any application including restaurants, apartment complexes and laundromats.

This interactive program includes a comprehensive cross reference guide that makes replacing any commercial or residential water heater with a Bradford White model quick and easy. You simply enter the model you wish to replace and the software will provide a Bradford White solution.

Scan the QR code to download the RightSpec® Cross-Reference Guide or any of our other FREE Apps!iPad/iPhone & Android Compatible

Visit Bradford White’s Interactive sizing and cross reference program at:

www.bradfordwhite.com

Also available as an APP!

RightSpec® - Interactive Sizing and Cross Reference

With RightSpec®, available on the web, you’ll have the sizing solution you need in a fraction of the time it took before.

page 94

page 95

Page 49: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLG2100H853N

LG155H803N LG2100H853NLG250H653N / LG275H763N

Commercial GasLight Duty Atmospheric Vent High Input Models

96/97

l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (LG250H653N model only) - Resettable Thermal Switch

- Maintenance-Free - Sight Window - Pedestal Basel Hydrojet 2™ Total

Performance System

l Vitraglas® Liningl Side Connections—3/4"

(19mm) NPT l Non-CFC Foam Insulationl Water Connectionsl Hand Hole Cleanoutl Protective Magnesium

Anode Rodl 4" (107mm) “Snap Lock”

Draft Diverterl T&P Relief Valvel Low Restriction Brass

Drain Valvel Thermostatic Mixing

Valve (ASSE Approved)(LG155H803N only)

65,00080,00076,00085,000

485575100

LG250H653NLG155H803NLG275H763NLG2100H853N

110N/AN/AN/A

60591/2625/869

222224

281/4

4915/16

497/8517/8595/16

193207263424

131413/16

15157/16

4444

NATURAL GAS MODELS Recovery100°F Rise*

A

Floor to Flue Conn.

1st HourRating(Gal.)

0.60N/AN/AN/A

EnergyFactor

63787482

NatU.S.GPH

53656269

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

565/85515/16

59651/2

F

Floor toTop ofHeater

1181116

H

C/L ofWaterConn.

577/8577/8607/16

6615/16

J

Floor toWaterConn.

26257/8271/4311/2

K

Depth

131/2157/16

165/81711/16

L

Floor toSpace

Heating Inlet

4915/16

497/8517/8505/8

M

Floor toSpace

Heating Outlet3/43/41

11/4

N

NPT

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.For 5 year models, change suffix “3” to “5”. *Based on manufacturer’s rated recovery efficiency. LG2100H853N model features hand hole cleanout.Energy Factor and First Hour Rating are based on the latest AHRI directory listings.NSF kits available. LG250H653X

LG155H803XLG275H763XLG2100H853X

LP GAS MODELS InputBTU/Hr.

61,00078,00076,00088,000

Recovery100°F Rise*

59767485

LPU.S.GPH

49636271

LPImp.GPH

ModelNumber

Light Duty Atmospheric Vent High Input ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 96

page 97

Page 50: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

C

A

G

F

E J

B

D & K

H

8"

Photo ofLC2PV50H763N

C

A

G

F

E J

B

D & K

H

8"

Commercial GasLight Duty High Efficiency eF Series® Power Vent Models 90%+ Thermal Efficiency

98/99

l Vertical, Dual-pass Heat Exchanger System

l Vitraglas® Protection—On both primary and secondary heat exchanger

l Self-priming Condensate Teel Power Ventl Horizontal and Vertical Ventingl Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics

l Hydrojet® Total Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Pedestal Basel Water Connections—3/4" NPTl 3/4" NPT Side Connections

l Heat Trapsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve

76,00050LC2PV50H763N 671/4 24 461/2 225135/82

Recovery90°F Rise*

Floor to Vent Conn.

83

U.S.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

Jacket Dia.

VentSize

Floor to T&P

Conn.

Floor toGas

Conn.

561/4

Floor toTop ofHeater

571/2

Floor toWaterConn.

273/8Depth

155/8

Floor toSpace

Heating Inlet

461/2

Floor toSpace

Heating Outlet

Approx.Shipping

Weight (lbs)

NATURAL GAS AND LIQUID PROPANEGAS MODELS

A B C D E F G H J K

2"Vent Pipe

3"Vent Pipe

4"Vent PipeLC2PV50H763N

†50 ft.7 ft.45 ft.40 ft.35 ft.

†120 ft.15 ft.115 ft.110 ft.105 ft.

†180 ft.15 ft.175 ft.170 ft.165 ft.

123

Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows

Subtract 5ft. for each additional 90° elbow.† For high altitude installations, consult the installation instructions.

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.* Based on 90.5% Thermal Efficiency.

Light Duty High Efficiency eF Series® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 98

page 99

Page 51: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLG2PV50H653N

B

H

K

C

J

F

E L

A

D&M

B

H

K

C

J

F

E L

A

D&M

Commercial GasLight Duty TTW® Power Vent Models

100/101

l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Powerful Blower Motor - 10 ft. Power Cord Included (120 VAC)

l Horizontal and Vertical Ventingl Defender Safety System® featuring the

patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Base

l Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulation

l Water Connections—3/4" NPT l 3/4" NPT Side Connectionsl Heat Trapsl Protective Magnesium Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE

Approved) (LG1PV55)

65,00078,00076,000

485575

LG2PV50H653NLG1PV55H783NLG2PV75H763N

112N/AN/A

661/8643/16

697/16

222226

501/84715/16

511/2

186253252

113/4111/2131/2

3 or 43 or 43 or 4

NATURAL GAS MODELS Recovery100°F Rise*

A

Floor to Flue Conn.

1st HourRating(Gal.)

0.70N/AN/A

EnergyFactor

637674

NatU.S.GPH

526362

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

563/8545/8591/2

F

Floor toTop ofHeater

11811

H

C/L ofWaterConn.

573/456

603/4

J

Floor toWaterConn.

263/4261/2301/4

K

Depth

131/2133/8133/8

L

Floor toSpace

Heating Inlet

501/84715/16

511/2

M

Floor toSpace

Heating Onlet

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models, change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

3" Vent Pipe

LG2PV50H653NLG1PV55H753NLG2PV75H753N

4" Vent Pipe

†50 ft.7 ft.45 ft.40 ft.35 ft.

123

Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows

†180 ft.15 ft.175 ft.170 ft.165 ft.

Subtract 5ft. for each additional 90° elbow† For high altitude installations, consult the installation instructions.

LG2PV50H653XLG1PV55H783XLG2PV75H763X

LP GAS MODELS Recovery100°F Rise*

InputBTU/Hr.

567673

58,00078,00075,500

LPU.S.GPH

476361

LPImp.GPH

ModelNumber

Light Duty TTW® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 100

page 101

Page 52: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLG2PDV50H603N

K

C

J F

EL

B

D & M

A H

K

C

J F

EL

B

D & M

A H

Commercial GasLight Duty Power Direct Vent Models

102/103

l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Defender Safety System® - Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Base

l Powerful Blower Model - 10 ft. Power Cord Included (120 VAC)

l Closed Combustion Venting System

l Cast Aluminum Air Intake Bootl Horizontal and Vertical Venting

l Optional Concentric Vent Kit Termination

l Hydrojet® Total Performance System

l Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections—

3⁄4" NPTl Side Connections—

3/4" NPT l Heat Trapsl Protective Magnesium

Anode Rodl T&P Relief Valvel Low Restriction Brass

Drain Valve

60,00080,000

4875

LG2PDV50H603NLG2PDV75H803N

105—

6972

2226

521/4541/4

205392

135/8161/4

3 or 43 or 4

NATURAL GAS MODELS Recovery100°F Rise*

A

Floor toExhaustOutlet

1st HourRating(Gal.)

0.68—

EnergyFactor

5877

NatU.S.GPH

4864

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

583/4623/4

F

Floor toTop ofHeat

67703/8

H

Floor toAir

Intake

60633/4

J

Floor toWaterConn.

305/836

K

Depth

153/419

L

Floor toSpace Heating

Return

521/4541/4

M

Floor toSpace Heating

Supply

Approx.Shipping

Weight (lbs)

Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models change suffix from “3” to “5”. * Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

INTAKE/COMBUSTION

AIR

RAINCAP

VENTEXHAUST

A 3" Vent Pipe

LG2PDV50H603NLG2PDV75H803N

4" Vent Pipe

60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.

123

Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows

100 ft.100 ft.7 ft.95 ft.90 ft.85 ft.

Subtract 5ft. for each additional 90° elbow.

Concentric Vent Kit Termination

3" Kit

P/N 239-44069-01 291/4

A (in.)

LG2PDV50H603XLG2PDV75H803X

LP GAS MODELS InputBTU/Hr.

Recovery100°F Rise*

5876

60,00078,000

LPU.S.GPH

4863

LPImp.GPH

ModelNumber

Light Duty Power Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 102

page 103

Page 53: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLG2DV50H503N

J

H

F

E L

B

D&MK

C C

A A

K

Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)

Commercial GasLight Duty Direct Vent Models

104/105

l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Defender Safety System® - Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Base

l Closed Combustionl Reinforced Sealsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kitl Side Connections—3/4" NPT l 2" Non-CFC Foam Insulationl Water Connections—3/4" NPT l Heat Traps

l Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valve

50,00048LG2DV50H503N 93 725/16 min. 22 521/4 217154 6

NATURAL GAS MODELS Recovery100°F Rise*

A

Floor to C/L ofVent

1st HourRating(Gal.)

0.60

EnergyFactor

47

NatU.S.GPH

39

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

I.D. O.D.

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

591/8

F

Floor toTop ofHeater

8

H

C/L ofWaterConn.

601/8

J

Floor toWaterConn.

31

K

Depth

153/4

L

Floor toSpace

Heating Inlet

521/4

M

Floor toSpace

Heating Outlet

Approx.Shipping

Weight (lbs)

All Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Solid Vent Kit: Part No. 239-51286-00. Weight: 22 lbs.Flexible Vent Kit: Part No. 239-51287-00. Weight: 13 lbs.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.

LG2DV50H503N Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00

InputBTU/Hr.

48,000LG2DV50H503X

LP GAS MODELS Recovery100°F Rise*

45

LPU.S.GPH

38

LPImp.GPH

ModelNumber

Light Duty Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 104

page 105

Page 54: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofULG275H763NModel ULG2100H853N

B

C

K

A

J

E F

G

D

H

L

M

C

L

A

J

H

E F

D&G

BK

M

Models ULG250H3N & ULG275H763N

Commercial GasLight Duty Ultra Low NOx Atmospheric Vent High Input Models

106/107

l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices

l Maintenance-Freel Sight Windowl Hydrojet 2™ Total

Performance Systeml Vitraglas® Liningl More Precise Temperature

Control l Side Connections—3/4" NPTl Non-CFC Foam Insulation

l Pedestal Base—ULG250&75l Water Connectionsl Protective Magnesium

Anode Rodl Hand Hole Cleanoutl 4" (107 mm) “Snap Lock”

Draft Diverterl T&P Relief Valvel Low Restriction Brass

Drain Valvel Design Certified by CSA

International (formerly AGA and CGA)

l ULG250H553N Complies with the Latest Ultra Low NOx Requirement (10 ng/J NOx limit), ULG275H763N / ULG2100H853N (14 ng/J NOx limit)

55,00076,00085,000

4875100

ULG250H553NULG275H763NULG2100H853N

100N/AN/A

605/16

641/8707/16

2226

281/4

497/8539/16

607/16

193263424

111/2151/8163/4

444

NATURAL GAS MODELS Recovery90°F Rise*

A

Floor to Flue Conn.

1st HourRating(Gal.)

0.60N/AN/A

EnergyFactor

597482

NatU.S.GPH

496269

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

133/8165/8183/4

F

Floor toSpace

HeatingReturn

497/8539/16

513/4

G

Floor toSpace

HeatingOutlet

563/8601/8681/8

H

Floor toTop ofHeater

5713/16

611/8665/8

J

Floor toWaterConn.

257/16

297/16

311/2

K

Depth

111116

L

C/Lof

WaterConn

3/41

11/4

M

NPT

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 5 year models, change suffix from “3” to “5”.* Based on manufacturer’s rated thermal efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Light Duty Ultra Low NOx Atmospheric Vent High Input ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

79% Recovery EfficiencyDIMENSIONS IN INCHES

page 106

page 107

Page 55: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

J

H

F

E

B K K

AA

C C

L

D&M

Photo ofULG2DV50H453N

Telescoping Solid Vent Kit (Side View) Flexible Vent Kit (Side View)

Commercial GasLight Duty Ultra Low NOx Direct Vent Model

108/109

l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Eco-Defender Safety System® - Digital Thermal Sensor

- Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary and

Secondary Air Distribution Devicesl Closed Combustionl Reinforced Sealsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kitl Side Connections—3/4" NPTl 2" Non-CFC Foam Insulationl Water Connections—3/4" NPT

l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valve

l Low Restriction Brass Drain Valvel Design Certified by CSA International (formerly AGA and CGA)l Complies with the Latest Ultra Low NOx Requirement (10 ng/J

NOx limit)

45,00048ULG2DV50H453N 88 741/4 min. 22 521/4 201154 6

NATURAL GAS MODELS Recovery100°F Rise*

A

Floor to C/L ofVent

1st HourRating(Gal.)

0.60

EnergyFactor

43

NatU.S.GPH

35

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

I.D. O.D.

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

591/4

F

Floor toTop ofHeater

11

H

C/L ofWaterConn.

601/8

J

Floor toWaterConn.

305/8

K

Depth

153/4

L

Floor toSpace

Heating Inlet

521/4

M

Floor toSpace

Heating Outlet

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Solid Vent Kit: Part No. 239-51286-00. Weight: 22 lbs.Flexible Vent Kit: Part No. 239-51287-00. Weight: 13 lbs.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.

Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00

Light Duty Ultra Low NOx Direct Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 108

page 109

Page 56: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofULG2PV50H603N

BH

C

J

A

G

E

D

F

BH

C

J

A

G

E

D

F

Commercial GasLight Duty Ultra Low NOx TTW® Power Vent Model

110/111

l Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices

l Eco-Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Digital Thermal Sensor

- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Bradford White ICON System™

- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Powerful Blower Motor - 10 ft. Power Cord Included (120 VAC)

l Horizontal and Vertical Ventingl Hydrojet® Total Performance

Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3/4" NPTl Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel All Models Comply with the Latest

Ultra Low NOx Requirement (10 ng/J NOx limit) except ULG2PV75H763N (14 ng/J NOx limit)

56,00076,000

4875

ULG2PV50H563NULG2PV75H763N

99N/A

663/8691/4

2226

497/8517/8

190270

113/4113/4

3 or 43 or 4

NATURAL GAS MODELS Recovery100°F Rise*

A

Floor toVent

Conn.

1st HourRating(Gal.)

0.70N/A

EnergyFactor

5474

NatU.S.GPH

5462

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

565/8591/2

F

Floor toTop ofHeater

5861

G

Floor toWaterConn.

261/2301/4

H

Depth

1111

J

C/L ofWaterConn.

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 5 year models, change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

† For high altitude installations, consult the installation instructions.

3" Vent Pipe

ULG2PV50H563NULG2PV75H763N

4" Vent Pipe

†50 ft.7 ft.45 ft.40 ft.35 ft.

123

Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows

†180 ft.15 ft.175 ft.170 ft.165 ft.

Ultra Low NOx TTW® Power Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES

page 110

page 111

Page 57: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofULG2PDV50H503N

K

N

A

JF

EL

B

D & M

C

H

K

N

A

JF

EL

B

D & M

C

H

K

N

A

JF

EL

B

D & M

C

H

Commercial GasLight Duty Ultra Low NOx Power Direct Vent Models

112/113

l Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices

Eco-Defender Safety System® - Digital Thermal Sensor

- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Closed Combustion Venting

Systeml Bradford White ICON

System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell

l Cast Aluminum Air Intake Boot

l Hydrojet® Total Performance System

l Vitraglas® Liningl Optional Concentric Vent

Kit Terminationl Horizontal and Vertical

Ventingl 2" Non-CFC Foam Insulationl Water Connections— 3⁄4"

NPT l Side Connections—3/4" NPT l Heat Trapsl Protective Magnesium

Anode Rodl T&P Relief Valvel Low Restriction Brass

Drain Valvel Complies with the Latest

Ultra Low NOx Requirement (10 ng/J NOx Limit)

50,00048ULG2PDV50H503N 92 691/4 22 521/4 201137/83 or 4

NATURAL GAS MODEL Recovery100°F Rise*

A

Floor to ExhaustOutlet

1st HourRating(Gal.)

0.68

EnergyFactor

48

NatU.S.GPH

40

NatImp.GPH

InputBTU/Hr.

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

VentSize

D

Floor to T&P

Conn.

E

Floor toGas

Conn.

691/4

F

Floor toTop ofHeater

583/4

H

Floor toAir

Intake

60

J

Floor toWaterConn.

32

K

Depth

153/4

L

Floor toSpace

Heating Return

521/4

M

Floor toSpace

Heating Supply

91/4

N

C/LDistance

FromIntaketoExhaust

Approx.Shipping

Weight (lbs)

Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.

Subtract 5ft. for each additional 90º elbow.

INTAKE/COMBUSTION

AIR

RAINCAP

VENTEXHAUST

A

3" Vent Pipe

ULG2PDV50H503N

4" Vent Pipe

60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.

123

Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows

100 ft.100 ft.7 ft.95 ft.90 ft.85 ft.

3" Kit

P/N 239-44069-01 361/4

A (in.)

Light Duty Ultra Low NOx Power Direct Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES

page 112

page 113

Page 58: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofUCG-100H-199-3N

Commercial GasCommander Series™ Atmospheric Vent Models

114/115

l ICON HD™ - Operation Mode - Service Mode

l Optional Air Intake Ductingl Premix Power Burnerl Direct Spark Ignitionl Integrated Exhaust Systeml Sanitizing Capabilityl Hydrojet® Sediment Reduction

Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connectionsl 1" NPT Side Connections for

Space Heatingl 82% Thermal Efficiencyl Zero Inch Clearance to

Combustibles (Excluding UCG-100H-399)

l Hand Hole Cleanoutl NSF Construction Availablel T&P Relief Valvel Low Restriction Brass

Drain Valvel Ultra Low NOx Construction

(14 ng/J NOx Emissions)l CSA Certified Low Lead Content

125,000199,999270,000399,999199,999270,000399,999

8080808010010098

UCG-80H-125-3NUCG-80H-199-3N UCG-80H-270-3NUCG-80H-399-3NUCG-100H-199-3NUCG-100H-270-3NUCG-100H-399-3N

63643/4643/4683/4731/4731/4771/4

5668668

44444444

521/2521/2521/2

535535545545632632657

47474747

551/2551/2551/2

10101010101010

GPH Recoveryat Degree Rise*

Floor to Top ofVent

308493665960493665994

40°F

123197266384 197266398

100°F

88141190274141190284

140°FInput

BTU/Hr.Gal.Cap.

ModelNumber

Vent Dia.

Floorto ColdWaterInlet

Floor to T&P

Conn.

Floor toHot Water

Outlet

611/4611/4611/4611/4693/4693/4693/4

Floor toTop ofHeater

553/4553/4553/4553/4631/4631/4631/4

Floor toGas

Conn.

30303030303030

Depth

281/4281/4281/4281/4281/4281/4281/4

Width

543/4543/4543/4543/4631/4631/4631/4

Floor to Cold Water

Inlet/HotWater Outlet

A B C D E F G H J K

11/211/211/211/211/211/211/2

WaterConn.Dia.

3/43/43/43/43/43/43/4

GasConn.Dia.

3/43/411

3/411

ReliefValveOpen

Approx.Shipping

Weight (lbs)

NATURAL GAS AND LIQUID PROPANEGAS MODELS

Model

Optional Air Intake Ducting Maximum Lengths

UCG-80H-125-3(N,X)UCG-80H-199-3(N,X)UCG-100H-199-3(N,X)UCG-80H-270-3(N,X)UCG-100H-270-3(N,X)UCG-80H-399-3(N,X)UCG-100H-399-3N

20 ft.20 ft.20 ft.20 ft.20 ft.N/AN/A

50 ft.50 ft.50 ft.50 ft.50 ft.25 ft.25 ft.

75 ft.75 ft.75 ft.75 ft.75 ft.50 ft.50 ft.

2" PVC, ABS,or CPVC

3" PVC, ABS,or CPVC

4" PVC, ABS,or CPVC

For Propane Gas models change suffix “N” to “X”. Example: UCG-100H-199-3X (UCG-100H-399 available in Natural Gas only). Natural gas models comply with the latest Ultra Low NOx requirements (14 ng/J or less). Amp Draw range = 1.0 to 1.8 amps.

Commander Series™ Atmospheric Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed82% Thermal EfficiencyDIMENSIONS IN INCHES

Optional Power Vent Kits – for side wall termination only.Model Numbers Kit NumberUCG-80H-125/199/270, UCG-100H-199/270: 239-81764-00UCG-80H-399, UCG-100H-399: 239-81766-00

page 114

page 115

Page 59: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofD-80T-180-3N

Commercial GasElectronic Ignition Water Heaters

116/117

l ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display - Operation Mode - Service Mode

l Electronic Ignitionl Automatic Flue Damper

l Hydrojet® Sediment Reduction Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water connections—True dielectric waterway

fittingsl Hand Hole Cleanoutl Automatic Re-Set E.C.O.l Magnesium Anode Rodsl Sanitizing Capability

l ASME Code Available on All Models above 200,000 BTU/Hr.

l NSF Construction Availablel Low NOx Construction Availablel North Carolina Code Compliantl T&P Relief Valvel Low Restriction Brass Drain Valve

Commercial Gas Burnerl Orifice Alignment Bracket for True Injectionl Stainless Steel Pilot Shieldl Stainless Steel Burner Rack and

Mounting Bracketl Aluminized Steel Burner Tubes with

Adjustable Air Shutter (Stainless Steel Burner Tubes Available)

l Opposing Lance Formed Burner Ports Yield Consistent Performance to Stabilize Burner Flame and Promote Better Air Gas Mixture

l Standard on Both “T” and “L” Commercial Energy Saver Models

Optional Power Vent Kits – available for inputsfrom 125,000 to 505,000.BTU Input Range Kit Number125,000 to 290,000 BTU’s: 239-81764-00300,000 to 399,999 BTU’s: 239-81766-00425,000 to 505,000 BTU’s: 239-82148-00

Typical ApplicationsB

A

H

E

C

F

D

B

J

H

A

E

C

F

D

B

A

H

E

C

F

D

D-38T-155 D-75T-(125, 160)D-80T-(180, 199,250)D-100T-(199, 250)D-100S-(199, 250)D-100L-(199, 250, 270, 300)

D-75T-300D-65T-(370, 399)D-80T-(425, 505)D-80L-(399, 450, 505)

page 116

page 117

Page 60: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Commercial GasElectronic Ignition Models

118/119

155,000125,000160,000180,000199,999250,000199,999250,000300,000370,000399,999425,000505,000

38757580808098987565658080

D-38T-155-3N+D-75T-125-3ND-75T-160-3ND-80T-180-3ND-80T-199-3ND-80T-250-3N(A)D-100T-199-3ND-100T-250-3N(A)D-75T-300-3N(A)D-65T-370-3N(A)D-65T-399-3N(A)†D-80T-425-3N(A)D-80T-505-3N(A)

177174208231250298263311344405424468527

37630338943648560648560672789797010301178

150121155175194242194242291359388412471

10786111124139173139173208256277294337

431/26565

641/2641/2641/2751/2751/2653/4643/4643/4751/2751/2

656666667881010

281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4

–––––

590–

690645720720800800

H

Floorto Top

ofHeater

B

JacketDia.

GPHRecovery

at °F Rise*

Approx.Shipping

Weight (lbs)

40° 100° 140° FirstHour**Rating

InputBTU/Hr.

Gal.Cap.

ModelNumber

VVVVVVVVVVVV

F V�������������

������������

�������������

� �

C

VentDia.

–671/8671/8661/4661/4661/4771/4771/4

–––––

J

Floorto TopWaterConn.

35541/2541/25656566767

541/8541/8541/8641/2641/2

D

FrontHot

WaterConn.

45/843/443/443/443/443/443/443/4101/2101/2101/2101/2101/2

E

Floorto GasConn.

51721/4721/4717/8717/8717/8833/8833/8743/8731/4731/4823/4823/4

A

TopVent

Height193/83434

191/2191/2191/2191/2191/22929292929

F

FrontCold

WaterConn. Std. ASME

11/2 (F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (F)

11/2 (F)

11/2 (F)

11/2 (F)

11/2 (F)

WaterConn.

3/43/43/43/43/43/43/43/43/4

1(N)

438520520540540540610610590665665750750

GasConn.Dia.

3/43/43/43/43/41

3/4111111

ReliefValveOpen.

NATURAL GAS MODELS

1(N)3/4 (LP)

1(N)3/4 (LP)

1(N)3/4 (LP)

1(N)3/4 (LP)

Electronic Ignition Models These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition).DIMENSIONS IN INCHES

199,999250,000199,999250,000270,000300,000399,999450,000505,000

100100100100100100808080

D-100S-199-3ND-100S-250-3N(A)D-100L-199-3ND-100L-250-3N(A)D-100L-270-3N(A)†D-100L-300-3N(A)D-80L-399-3N(A)D-80L-450-3N(A)D-80L-505-3N(A)

264312264312332361444492545

48560648560665572797010911224

194242194242262291388436489

139173139173187208277312350

677/8677/8643/4643/4643/4643/4601/4601/4601/4

66666781010

281/4281/4301/4301/4301/4301/4301/4301/4301/4

–702–

765765765835835835

H

Floorto Top

ofHeater

B

JacketDia.

GPHRecovery

at °F Rise*

Approx.Shipping

Weight (lbs)

40° 100° 140°FirstHour**Rating

InputBTU/Hr.

Gal.Cap.

ModelNumber

FF

VVVVVVVVVVV

F V�����������

�����������

�����������

� �

C

VentDia.

707067676767–––

J

Floorto TopWaterConn.

603/8603/8561/2561/2561/2561/2511/2511/2511/2

D

FrontHot

WaterConn.

45/845/841/241/241/241/2101/2101/2101/2

E

Floorto GasConn.

763/4763/4757575

753/8711/26969

A

TopVent

Height203/4203/4231/2231/2231/2231/2231/2231/2231/2

F

FrontCold

WaterConn. Std. ASME

WaterConn.

3/43/43/43/43/43/4

667667725725725725800800800

GasConn.Dia.

3/41

3/4111111

ReliefValveOpen.

NATURAL GAS MODELS

1(N)3/4 (LP)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (F)2 (R)

11/2 (F)2 (R)

11/2 (F)2 (R)

1(N)3/4 (LP)

1(N)3/4 (LP)

1(N)3/4 (LP)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (F)

11/2 (F)

11/2 (F)

(A) = ASME Code Available(F) = Front Water Connection(T) = Top Water Connection † = Available in Natural Gas Only + = Fiberglass InsulationFor (LP) Propane Gas models change suffix “N” to “X”.

* Based on manufacturer’s rated recovery efficiency.** Recoveries are based on 80% Thermal Efficiency . Low NOx models are not available for inputs over 399,999For Low NOx compliance place an “E” following the BTU input identifier of the model number. Example: D-75T-125E-3NAmperage Draw = .5 for damper models/less than 4 for induced draft models.Power Vent Kits – available for inputs from 125,000 to 505,000.

LP GAS MODELSInput

BTU/Hr.GPH Rec.

40° 100º 140º

D-75T-160-3X 155,000 376 150 107

D-80T-250-3X 235,000 570 228 163

D-100T-250-3X 235,000 570 228 163

D-80L-399-3X 375,000 909 364 260

D-80L-450-3X 425,000 1030 412 294D-80L-505-3X 475,000 1152 461 329

Electronic Ignition Models These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition).DIMENSIONS IN INCHES

page 118

page 119

Page 61: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

E

F

D

A

C

G

39 7/8"DEPTH

B

E

F

D

A

C

G

39 7/8"DEPTH

B

Photo ofD-65T-625-3NA

Commercial GasInduced Draft Models

120/121

l ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display - Operation Mode - Service Mode

l Electronic Ignitionl Hydrojet® Total Performance Systeml Vitraglas® Liningl Automatic Re-Set E.C.O.l Non-CFC Foam Insulationl Water Connections—11⁄2" NPT front

true dielectric fittingsl Protective Magnesium Anode Rodsl Hand Hole Cleanoutl Sanitizing Capabilityl NSF Construction Availablel ASME Construction Available

l T&P Relief Valvel Low Restriction Brass Drain Valve

625,000725,000

6580

D-65T-625-3N(A)D-80T-725-3N(A)

15151757

606703

433502

693/8795/8

653/4743/4

281/4281/4

A

Floorto

HeaterTop

B

JacketDia.

GPHRecovery

at °F Rise*

40° 100° 140°

Nat. &LP

InputBTU/Hr.

Gal.Cap.

ModelNumber

VV

V � �

��

�F

J

Floorto TopWaterConn.

445/8445/8

GasConn.

88

C

VentDia.

687/8791/8

G

Floorto

VentHeight

203/4203/4

F

FrontCold

WaterConn.

541/8641/4

D

Floorto HotWaterConn.

287/8287/8

E

Floorto ColdWaterConn.

101/2101/2

F

Floorto GasConn.

695/8

785/8

A

TopVent

Height11

ReliefValveOpen

1†1†

GasConn.Dia.

WaterConn.

NATURAL GAS MODELS

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

775880

Approx.Shipping

Weight (lbs)

Std. ASME720800

(A) = ASME Code Available For Propane Gas models change suffix “N” to “X”.† LP Gas connection 3/4".* Based on manufacturer’s rated recovery efficiency.** Recoveries are based on Thermal Efficiencies of 80%.

Induced Draft Models These models meet or exceed both Thermal Efficiency and StandbyLoss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. Listed

80% Thermal EfficiencyDIMENSIONS IN INCHES

page 120

page 121

Page 62: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofDM-75T-125-3N

Commercial GasMillivolt Models

122/123

l No Electricity Requiredl ASME Code Available on All Models above 200,000 BTU/Hr.l Continuous pilot-ignitionl Piezo Igniter—Easy and quick lighting by the pilot burner by push buttonl Millivolt Controlsl Automatic Flue Damperl Vitraglas® Liningl Hydrojet® Sediment Reduction Systeml Dielectric Fittingsl Non-CFC Foam Insulationl Hand Hole Cleanout (Standard)l NSF Construction Availablel T&P Relief Valvel Low Restriction Brass Drain Valvel 3 Year Limited Tank Warranty

Water ConnectionsTop and FrontDM80T180, 199, 250DM100T199, 250DM75T125, 160Top FrontDM100L199, 250, 270DM100S199, 250

Water ConnectionsFront and RearDM38T155

C

B

F

J

D

E

COLD

HOT

T & P

A

H

CLEANOUT

H

C

B

F

D

E

HOT

T & P

A

J

COLD CLEANOUT

page 122

page 123

Page 63: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

155,000125,000160,000180,000199,999250,000199,999250,000199,999250,000270,000199,999250,000

3875758080809898100100100100100

DM-38T-155-3NDM-75T-125-3NDM-75T-160-3NDM-80T-180-3NDM-80T-199-3NDM-80T-250-3N(A)DM-100T-199-3NDM-100T-250-3N(A)DM-100L-199-3NDM-100L-250-3N(A)DM-100L-270-3N(A)†DM-100S-199-3NDM-100S-250-3N(A)

174174208231250298264311264312332264312

368303378436485606485606485606655485606

147121151175194242194242194242262194242

10786108124139173139173139173187139173

436565

641/2641/2641/2751/2751/2656565

727/8727/8

6566666666666

281/4281/4281/4281/4281/4281/4281/4281/4301/4301/4301/4301/4301/4

—————590—690—765765—702

H

Floorto Top

ofHeater

B

JacketDia.

GPHRecovery

at °F Rise*

Approx.Shipping

Weight (lbs)

40° 100° 140°

FirstHour**Rating

InputBTU/Hr.

Gal.Cap.

ModelNumber F V �

�������������

�������������

� �

C

VentDia.

—671/8671/8661/4661/4661/4771/4771/46767677575

J

Floorto TopWaterConn.

341/2541/2541/25656566767

561/2561/2561/2601/2601/2

D

R/FHot

WaterConn.

45/843/443/443/443/443/443/443/441/241/241/241/241/2

E

Floorto GasConn.

51721/4721/4723/8723/8723/8833/8833/8757575

763/4763/4

A

TopVent

Height193/83434

191/2191/2191/2191/2191/2231/2231/2231/2203/4203/4

F

R/FCold

WaterConn. Std. ASME

WaterConn.

3/43/43/43/43/43/43/43/43/43/43/43/43/4

3/43/43/43/43/41

3/41

3/411

3/41

438520520540540540610610725725725667667

GasConn.Dia.

ReliefValveOpen.

NATURAL GAS MODELS

11/211/211/211/211/211/211/211/2

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/211/211/211/211/211/211/211/2

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

11/2 (T&F)

Commercial GasMillivolt Models

124/125

Millivolt Models These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. ListedDIMENSIONS IN INCHES

(A) = ASME Code Available(F) = Front Water Connection(T) = Top Water Connection † = Available in Natural Gas Only For Propane Gas models change suffix “N” to “X”.

For LowNOx compliance, place an “E” following the BTU Input identifier of the model number. Example: DM-75T-125E-3N* Based on manufacturer’s rated recovery efficiency.** Recoveries are based on Thermal Efficiencies of 80%.

LP GAS MODELSInput

BTU/Hr.GPH Rec.

40° 100º 140ºDM-75T-160-3X 155,000 376 150 107DM-80T-199-3X 190,000 461 184 132DM-80T-250-3X 235,000 570 228 163DM-100T-250-3X 235,000 570 228 163

page 124

page 125

Page 64: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

H

G

C

C

F

E

J

A

B

DCLEANOUT

21/2"

1/2"

MIN.

NPTCONDENSATECONNECTION

11/2"NPT

OUTLET

11/2"NPT

INLET

1" NPTSPACE

HEATINGOUTLET

1" NPTSPACE

HEATINGRETURN

3" PVCEXHAUST

3" PVC INLET 3/4" NPT GAS INLET

T&P VALVE

AIR INTAKE

GAS INLETEXHAUST

81/4"

81/4"

Photo of EF-60T-199E-3N

Commercial GasUltra High Efficiency Models

126/127

l ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display

l ASME Construction Availablel Electronic Controlsl Low-NOx Premix

Power Burnerl Three Pass Flue Systeml Flexible Venting Optionsl Vitraglas® Liningl Hydrojet® Sediment

Reduction Systeml Dielectric Fittings

l Non-CFC Foam Insulationl Four Protective Magnesium

Anode Rods (Except EF-100T-399)

l Two Powered Anode Rods and One Non-Powered Anode Rod in the EF-100T-399

l Hand Hole Cleanoutl Zero Inch Clearance

to Combustiblesl NSF Construction Availablel T&P Relief Valvel Low Restriction Brass

Drain Valvel Complies with the Latest

Ultra-Low NOx Requirement (14 ng/J NOx Limit)

606060100100100100100

VVVVVVVV

EF-60T-125E-3N(A)EF-60T-150E-3N(A)EF-60T-199E-3N(A)EF-100T-150E-3N(A)EF-100T-199E-3N(A)EF-100T-250E-3N(A)EF-100T-300E-3N(A)EF-100T-399E-3N(A)

187211265250309364405518

3644235584505977358361127

145169223180239294335451

104121159129171210239322

575757

775/8775/8775/8775/8775/8

421/2421/2421/2621/2621/2621/2621/263

281/4281/4281/4281/4281/4281/4281/4281/4

570570570900900900900950

H

Floor toTop ofHeater

55555555

J

Floor toVent

Conn.

B

JacketDia.

33333333

C

Vent& AirIntakeSize

GPHRecoveryat °F Rise

40° 100° 140°FirstHour**Rating

125,000150,000199,999150,000199,999250,000300,000399,999

InputBTU/Hr.

Gal.Cap.

ModelNumber V

��������

��

G

HotWaterOutletConn.

127/8127/8127/8127/8127/8127/8127/813

F

ColdWaterInlet

Conn.531/2531/2531/2743/4743/4743/4743/4741/4

521/2521/2521/2731/8731/8731/8731/8731/8

E

Floorto GasConn.

51/851/851/851/851/851/851/851/8

F

Floorto VentOutlet

A

Floorto AirIntake

3/43/43/43/43/43/43/41

GasConn.Dia.

3/43/43/43/43/4111

ReliefValveOpen

11/211/211/211/211/211/211/211/2

WaterConn.

4040406060606060

D

Floorto T&PValveConn.

Approx.Shipping

Weight (lbs)

NATURAL GAS AND LIQUID PROPANE GAS MODELS

(A) = ASME Code Available For Propane Gas models change suffix “N” to “X” and remove “E” from model number Example: EF-100T-150-3X. Note: The weight is the same for both ASME and Non-ASME models. NSF Compliance Kit—p/n 265-44542-04. ** Recoveries are based on the listed Thermal Efficiencies.

Ultra High Efficiency Models These models meet or exceed both Thermal Efficiencyand Standby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. ListedDIMENSIONS IN INCHES

page 126

page 127

Page 65: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Commercial GasUltra High Efficiency Models

128/129

Max. Intake LengthMax. Exhaust Length

15 ft.15 ft.

N/A30 ft.

PowerDirect Vent

PowerVent

EF-60T-125

15 ft.15 ft.

N/A30 ft.

PowerDirect Vent

PowerVent

EF-60T-150EF-100T-150

15 ft.15 ft.

N/A30 ft.

PowerDirect Vent

PowerVent

EF-60T-199EF-100T-199

2” Vent Pipe

Max. Intake LengthMax. Exhaust Length

60 ft.60 ft.

N/A120 ft.

PowerDirect Vent

PowerVent

EF-60T-125EF-100T-150

50 ft.50 ft.

N/A100 ft.

PowerDirect Vent

PowerVent

EF-60T-150EF-100T-199

40 ft.40 ft.

N/A80 ft.

PowerDirect Vent

PowerVent

EF-60T-199EF-100T-250

30 ft.30 ft.

N/A60 ft.

PowerDirect Vent

PowerVent

EF-100T-300

25 ft.25 ft.

N/A50 ft.

PowerDirect Vent

PowerVent

EF-100T-399

3” Vent Pipe

Max. Intake LengthMax. Exhaust Length

85 ft.85 ft.

N/A170 ft.

PowerDirect Vent

PowerVent

EF-60T-125EF-100T-150

75 ft.75 ft.

N/A150 ft.

PowerDirect Vent

PowerVent

EF-60T-150EF-100T-199

65 ft.65 ft.

N/A130 ft.

PowerDirect Vent

PowerVent

EF-60T-199EF-100T-250

55 ft.55 ft.

N/A110 ft.

PowerDirect Vent

PowerVent

EF-100T-300

50 ft.50 ft.

N/A100 ft.

PowerDirect Vent

PowerVent

EF-100T-399

4” Vent Pipe

eF Series® Optional Equipment Features:

Maxitrol Gas Pressure Regulating Valve—Ensures proper supply pressure to eF unit of 7" to 11" W.C.(provided incoming pressure is between 1/2 and 2 psi). This can be ordered as a separate part, or as part of the heater. For the separate part, please use p/n 243-45517-00 (not available for use with the EF-100T-399).

NSF Compliance Option—p/n 265-44542-04

Low Gas Inlet Pressure Option—Pre-assembled to allow operation at lower inlet natural gas pressure.

Intake/CombustionAir Rain Cap

VentExhaust

36 1/4"

Concentric Vent Terminal Kit—3” termination fitting provides for only one exit opening through wall or roof (p/n 239-44069-01).

p/n 239-44069-01p/n 239-44069-02 (for 2” vent pipe only)

page 128

page 129

Page 66: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Incoloy Element Availability Chart

yesnonononononononono

120V

1500200025003000350040004500500055006000

Watts

yesyesyesyesyesyesyesyesyesyes

208V

yesyesyesyesyesyesyesyesyesyes

240V

noyesnoyesnoyesyesyesyesyes

277V

noyesnoyesnoyesyesyesyesyes

480V

Commercial ElectricWater Heaters

130/131

Specify voltage and wattage when ordering.

All models are ETL listed. All water connections are 3⁄4" NPT (LE2120T has 1" NPT). All electrical connections are 3⁄4". All models are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped with two installed heat traps (except LE2120T, LE120L, Utility and Wall Hung models). All models include an installed T&P Relief Valve.

Note: All Upright and Lowboys will be wired 240 Volt with two 4500 watt elements, 3 phase non-simultaneous operation (except 277 volt; 277 volt is only available in single phase operation). Other wattages and voltages are available. These models are field convertible to single phase and simultaneous operation. All models have a maximum total wattage of 3000 watts at 120 Volt. Incoloy® elements available for most inputs.

Note: All Wall Hung and Utility Models will be wired 120 Volt with a 1500 watt element as single phase operation. 3 phase wiring not available on Wall Hung or Utility models (Single Element Units). Other wattages and voltages are available. Maximum wattage for 6 and 12 gallon tall utility models is 3000W. Maximum wattage for 10, 12 and 15 gallon utility models is 6000W. Maximum wattage for the 6 gallon wall hung model is 3000W. Maximum wattage for 12, 20 and 30 gallon wall hung models is 6000W. All models have a maximum wattage of 3000 watts at 120 Volt. Incoloy® elements available for most inputs.

Wattage Limitations for Non-Simultaneousand Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

NOTE: WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE AND kW INPUT ONLY. THE FOLLOWING TABLES ARE FOR INFORMATIONAL PURPOSES ONLY.Phase and Operation are determined by the voltage. All 208V, 240V and 480V models are shipped standard three phase, non-simultaneous. Can be converted to single phase and/or simultaneous operation in the field.All 120V and 277V models are shipped standard single phase, non-simultaneous. Can be converted to simultaneous operation in the field. Three phase not available.

EX: LE250S3-3NCWW EX: LE250S3-3NCWW

EX: LE250S3-3NCWW

EX: LE250S3-3ge designator if wiring 208V with 5000, 5500 or 6000 watt. † Available in non-simuNCWW, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of 3500W/3500W. ** Use “L” voltaltaneous only.

EX: LE250S3-3NCWW* Use “L” voltage designator if wiring 208V with 5000 watt.

For 120V, 277V, 480V, and 600V operation

For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)

Phase1 Single Phase3 Three Phase

OperationN Non-SimultaneousS Simultaneous

Designator A C E H J L*Voltage 120 208/240 277 480 600 208

Designator J K L M N P R S T W X Y ZWattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 6000

Designator J K L M N P R S T W X Y Z X** Y** Z**240V Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 — — — —208V Wattage — — 1000 1500 2000 — 2500 — 3000 3500 — 4000 4500 5000 — —

page 130

page 131

Page 67: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLE250S3-3

B

C

A

D

B

C

A

D

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

Commercial ElectricElectriFLEX LD™ (Light Duty) Upright Models

132/133

l Fully Automatic Controlsl Direct Heat Transfer with Immersed Elementsl Hydrojet® Total Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Traps l Protective Magnesium Anode Rodl Steel Tankl Field Convertiblel Voltages Available—120V, 208V, 240V, 277V, 480V.l T&P Relief Valve

3040506580119

LE230S3-3LE240S3-3LE250S3-3LE265T3-3LE280T3-3LE2120T3-3

467/8467/8461/2591/4591/4623/4

182022222428

473/16

467/8461/2591/4591/4621/4

85103130156183305

481/8477/8471/2601/4601/4641/4

ELECTRIC MODELS Recovery100°F Rise*

A

Floor toHeater Top

181818181818

NatU.S.GPH

151515151515

NatImp.GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor toWater Conn.

D

Floor toT&P Conn.

Approx.Shipping

Weight (lbs)

Specify wattage and voltage when ordering. Use chart below for maximum wattages at certain voltages For 5 year models, change suffix “3” to “5”.* Based on 4500W/4500W, Non-Simultaneous operation. NSF Kits available when ordering.

s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)

Wattage Limitations for Non-Simultaneousand Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

Wattage Limitations for Non-Simultaneousand Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

ElectriFLEX LD™ (Light Duty) Upright ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 132

page 133

Page 68: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLE120S3-3

B

C

A

D

B

C

A

D

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

Commercial ElectricElectriFLEX LD™ (Light Duty) Lowboy Models

134/135

l Fully Automatic Controlsl Direct Heat Transfer with Immersed

Elementsl Hydrojet® Total Performance Systeml Vitraglas® Liningl 1" Non-CFC Foam Insulationl Water Connections—3⁄4" NPT l Heat Trapsl Protective Magnesium Anode Rodl Steel Tankl Field Convertiblel Voltages Available—120V, 208V, 240V,

277V, 480Vl T&P Relief Valve

19304047

LE120L3-3†LE130L3-3**LE140L3-3**LE150L3-3**

243/4293/4311/4313/4

18202224

191/4 / 247/824 / 293/8

241/8 / 313/4241/8 / 313/4

5886115140

2631

327/8331/8

ELECTRIC MODELS Recovery100°F Rise*

A

Floor toHeater Top

18181818

NatU.S.GPH

15151515

NatImp.GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor toWater Conn.

D

Floor toT&P Conn.††

Approx.Shipping

Weight (lbs)

s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)

Wattage Limitations for Non-Simultaneousand Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

Wattage Limitations for Non-Simultaneousand Simultaneous Operation

Voltage120V 208V 240V 277V 480V

Recovery�GPH Temperature Rise ºF

60 80 90 100 120Wattage

yesnonononononononono

yesyesyesyesyesyesyesyesnono

yesyesyesyesyesyesyesyesyesno

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

Specify wattage and voltage when ordering. Use the charts to the right for maximum wattages at certain voltages. All Models include supplied insulation blanket. For 5 year models, change suffix “3” to “5”.* Based on 4500W/4500W, Non-Simultaneous operation.** Models include supplied insulation blanket (2" thick). Dimensions in charts above do not include blanket thickness NSF Kits available when ordering.† Exempt from ASHRAE 90.1b.†† All models feature side T&P location and must specify top T&P when ordering. “D” dimension listed as side/top.

ElectriFLEX LD™ (Light Duty) Lowboy ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 134

page 135

Page 69: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

4" ALTERNATECOLD INLET(PLUGGED)6 & 12 GAL.

ONLY

PLUG TYPEANODE6 & 12

GAL. ONLY

ALTERNATE HOTOUTLET (PLUGGED)

6 & 12 GAL. ONLY

8"

B

F

F

C

E

D

A

B

C D

F

E

A

Photo ofLE112T3-1

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

6, 12, & 20 Gallon Models

10 & 15 Gallon Models

Commercial ElectricElectriFLEX LD™ (Light Duty) Utility Models

136/137

l Fully Automatic Controlsl Direct Heat Transfer with a Single

Immersed Elementl Vitraglass® Liningl 1" Non-CFC Foam Insulationl Water Connections—3/4" NPT l Alternate Top Water Connectionsl Protective Magnesium Anode Rodl Steel Tankl Voltages Available—120V, 208V, 240V,

277V, 480Vl Single Phase Operation Onlyl T&P Relief Valve

610121519

LE16U3-1†LE110U3-1LE112T3-1†LE115U3-1LE120U3-1

161/2171/2273/4201/4243/4

1416141818

101/814

211/8

163/4181/4

3348485559

101/815

211/8173/4181/4

ELECTRIC MODELS Recovery100°F Rise*

A

Floor toHeater Top

66666

NatU.S.GPH

55555

NatImp.GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Floor to Hot Water Conn.

31/8

511/16

361/83

E

Floor to ColdWater Conn.

161/2

911/16

273/4101/8101/4

F

Floor toAnode Rod

D

Floor toT&P Conn.

Approx.Shipping

Weight (lbs)

WattageLimitations 120V 208V 240V 277V 480V

RecoveryGPH Temperature Rise ºF

60 80 90 100 120Wattage

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

VoltageWattage

Limitations 120V 208V 240V 277V 480V

RecoveryGPH Temperature Rise ºF

60 80 90 100 120Wattage

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

Voltage Specify wattage and voltage when ordering. Use chart to right for maximum wattages at certain voltages.† Maximum wattage at any voltage is 3000W. For 5 year models, change suffix “3” to “5”. Single element only.* Based on 1500W operation. NSF Kits available when ordering.

ElectriFLEX LD™ (Light Duty) Utility ModelsC.E.C. ListedDIMENSIONS IN INCHES

page 136

page 137

Page 70: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofLE16WV3-1

TOPVIEW

D

C

WALL

HOTOUTLET

COLDINLET

ELECTRICAL JUNCTION BOX

8"

A AFRONTVIEW

1213/16"D

HOT OUTLET3/4" CONN.

COLD INLET3/4" CONN.

E

3/4" RELIEF VALVE OPENING

SIDEVIEW

WALL

B

BOTTOMVIEW

FRONT

HEATINGELEMENT &THERMOSTATACCESS

B

Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)

Commercial ElectricElectriFLEX LD™ (Light Duty) Wall Hung Models

138/139

l Fully Automatic Controlsl Direct Heat Transfer with a Single

Immersed Elementl Vitraglas® Liningl 1" Non-CFC Foam Insulationl Heavy-Duty Wall Mounting Bracketl Water Connections—3/4" NPT

l Protective Magnesium Anode Rodl Steel Tankl Voltages Available—120V, 208V,

240V, 277V, 480Vl Single Phase Operation Onlyl T&P Relief Valve

61219

LE16WV3-1†LE112WV3-1LE120WV3-1

153/4163/8243/8

141818

113/4123/4181/4

334859

145/8185/8185/8

ELECTRIC MODELS Recovery100°F Rise*

A

Height

666

NatU.S.GPH

555

NatImp.GPH

Gal.Cap.

ModelNumber

B

Jacket Dia.

C

Wall toFront

117/8

121/221

E

Height toT&P Conn.

D

Height toBracket

Approx.Shipping

Weight (lbs)

WattageLimitations 120V 208V 240V 277V 480V

RecoveryGPH Temperature Rise ºF

60 80 90 100 120Wattage

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

VoltageWattage

Limitations 120V 208V 240V 277V 480V

RecoveryGPH Temperature Rise ºF

60 80 90 100 120Wattage

yesyesyesyesnononononono

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesyesyesyesyesyesyes

yesyesyesyesnoyesyesyesnoyes

yesyesyesyesnoyesyesyesnoyes

10141721242831343841

8101315182123262931

791114161821232528

681012141619212325

57910121415171921

1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W

1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W

Voltage

Specify wattage and voltage when ordering. Use chart to right for maximum wattages at certain voltages. † Maximum wattage at any voltage is 3000W. For 5 year models, change suffix “3” to “5”. Single element only.* Based on 1500W operation. NSF Kits available when ordering.

ElectriFLEX LD™ (Light Duty) Wall Hung ModelsC.E.C. ListedDIMENSIONS IN INCHES

page 138

page 139

Page 71: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofE32-80R-3

A&DC

B

F

E10"

8"

3 1/8"

A&DC

B

F

E10"

8"

3 1/8"

Commercial ElectricElectriFLEX MD™ (Medium Duty) Models

140/141

l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—11⁄4" NPT dielectric waterway fittingsl 2" Non-CFC Foam Insulationl Fully Automatic Controls (180°F maximum)l Direct Heat Transfer with Immersed Elementsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain ValveOptional Field Conversion Kits; see next page for part numbers NSF Construction Kits; see next page for part numbers

32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000

5080119

E32-50S-3E32-80R-3E32-120R-3

50 2059 1/8483/858

59 3/850

603/459 5/8493/4581/2603/4633/46811/16

2224

281/4

461/25963

137190312

245/8263/4307/8

ELECTRIC MODELS A

Floorto FlueConn.

B

JacketDia.

GPHRecovery

90°F Rise*

1st Hour**DeliveryRating

InputBTU/Hr.

GallonCapacity

ModelNumber

A

Floor toHeater Top

471/26064

C

Floor toWater Conn.

447/8573/8613/8

E

Floor to Control Box

475/8601/8641/8

D

Floor toT&P Conn.

F

Control Boxto Back

of Heater

Approx.Shipping

Weight (lbs)

All Medium Duty heaters are wired 240V/3 phase 18 kW. Other voltages, wiring phase and kW are available and must be specified when ordering. NOTE: Refer to pages 130/131 for technical information and pages 150/151 for GPH recovery information.

RequiredTotal

HeaterWattage

ElementWattage

Kit Part Numbers

208V

Conversion Kit Table

240V 480V60009000

12000135001500018000

200030004000450050006000

265-43942-13265-43942-14265-43942-15265-43942-16265-43942-17265-43942-18*

265-43942-07265-43942-08265-43942-09265-43942-10265-43942-11265-43942-12

265-43942-01265-43942-02265-43942-03265-43942-04265-43942-05265-43942-06

208V 240V 277V

Full Load Amperes - (Single Phase / Three Phase) and Recovery at a 100°F Rise

380V 415V 480V Recovery28.8/16.743.2/25.057.7/33.364.9/37.572.1/41.686.5/50.0

Input kW6912

13.51518

25.0/14.437.5/21.750.0/28.956.3/32.562.5/36.175.0/43.3

21.732.543.348.754.265.0

9.113.718.220.522.827.3

8.312.516.718.820.925.0

12.5/7.218.8/10.825.0/14.428.1/16.231.3/18.037.5/21.7

25 GPH37 GPH50 GPH56 GPH62 GPH74 GPH

ModelNumber Kit Part Numbers

NSF Construction Kit

E32-50SE32-80RE32-120R

265-45446-01265-45446-02265-45446-03

1,000 watts = 1kW.* 265-43942-18 will require control box replacement (included in kit). Other wattages, wiring phase and kW are available and must be specified when ordering. 277 volt cannot be ordered as 3 phase operation.

ElectriFLEX MD™ (Medium Duty) ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 140

page 141

Page 72: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

E C

DA

B

F

Photo ofCEHD80(A)-KW-3CF

Commercial ElectricElectriFLEX HD™ (Heavy Duty) Models

142/143

Immersion Thermostat with Contactorsl Immersion Type Thermostat for

Accurate Temperature Control from Positive off up to 180°F

All Models Featurel Vitraglas® Lined Tankl Hydrojet® Sediment Reduction

Systeml Completely Pre-wired with Pressure

Lug Terminal Eliminating the Need for Splicing or Taping Wires

l Water Connections—11⁄2" NPT true dielectric fittings

l 3" Non-CFC Foam Insulationl Two Protective Magnesium

Anode Rodsl Hand-hole Cleanout Openingl Internal Fusing—Standard on all

models

l Low Restriction Brass Drain Valvel T&P Relief ValveOptionsl ASME & NSF Construction

Available

300,000360,000

5080119

CEHD50(A)-KW-3CFCEHD80(A)-KW-3CFCEHD120(A)-KW-3CF

347419

728873

291349

208249

503/16

60641/2

461/2461/2501/4

2426

301/4

493/4 / 563/8 383/4

493/4 / 551/450 / 565/841 / 471/4511/2 / 5850 / 567/8

401/2 50 / 553/4501/2 / 58

33595/16

A

Floor to Heater

Top

B

JacketDia.

GPHRecovery

at Degree Rise*

40° 100° 140°

1st HourDeliveryRating

Nat. &LP

InputBTU/Hr.

Gal.Cap.

ModelNumber

E

Floor toCold

WaterInlet611/16

611/16

63/4

F

Floor toTop ofControl

Box525/8651/2663/4

D

Floor toHot

WaterOutlet

407/16

511/2549/16

C

Floor toT&P

Conn.WaterConn.

ELECTRIC MODELS 11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

302378485

Approx.Shipping

Weight (lbs)

Std. ASME270335430

11/211/211/2

Voltage and phase must be specified when ordering. Example: CEHD50-12-3CF, 240 Volt, 3 phase.All models available in 208/240/277 and 480 volt.(A) ASME Construction available.For ASME construction add “A” to the model number.Example: CEHD50A-12-3CF, 240 Volt, single phase.NOTE: Refer to pages 130/131 for technical information and pages 150/151 for GPH recovery information.

HOT

COLD45°

15 1/8"

22 1/8"19 1/2"

HOT

COLD 52°

13"

56°T & P 47°

T & P

HOT

COLD 58°

12"

18 1/2"

63°T & P

CEHD50 CEHD80 CEHD120

ElectriFLEX HD™ (Heavy Duty) ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 142

page 143

Page 73: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

E C

DA

Hot

B

T&PValve

ColdWaterSupply

F

Photo ofM-II-50-36-3SF

Commercial ElectricSurface and Immersion Thermostat Models

144/145

Immersion Thermostat with Contactorsl Immersion Type Thermostat for

Accurate Temperature Control from Positive off up to 180°F

Surface Mounted Thermostatsl Thermostat Step Control Can Be

Accomplished by Variable SettingsAll Models Featurel Vitraglas® Lined Tankl Hydrojet® Sediment Reduction

Systeml Completely Pre-wired with Pressure

Lug Terminal or Fuse Block Eliminating the Need for Splicing or Taping Wires

l Water Connections—11⁄2" NPT true dielectric fittings

l 3" Non-CFC Foam Insulation

l Two Protective Magnesium Anode Rods

l Hand-hole Cleanout Openingl Low Restriction Brass Drain Valvel T&P Relief ValveOptionsl ASME & NSF Construction

Available on Immersion and Surface Thermostats

300,000360,000

5080119

M-II-50-kW-3SFM-II-80-kW-3SFM-II-120-kW-3SF

347419

728873

291349

208249

473/4601/4641/2

461/2461/2501/4

2426

301/4

493/4 / 563/8 383/4

493/4 / 551/450 / 565/841 / 471/4511/2 / 5850 / 567/8

401/2 50 / 553/4501/2 / 58

33595/16

A

Floor to Heater

Top

B

JacketDia.

GPHRecovery

at Degree Rise*

40° 100° 140°

1st HourDeliveryRating

Nat. &LP

InputBTU/Hr.

Gal.Cap.

ModelNumber

E

Floor toTop ofControl

Box63/463/463/4

F

Floor toCold

WaterInlet

491/4613/466

D

Floor toHot

WaterOutlet

41521/255

C

Floor toT&P

Conn.WaterConn.

ELECTRIC MODELS 11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

11/2 (T&F)2 (R)

302378485

Approx.Shipping

Weight (lbs)

Std. ASME270335430

11/211/211/2

Model numbers shown are for Surface Mount thermostats. For Immersion thermostat change suffix “SF” to “CF”.Voltage and phase must be specified when ordering. Example: M-II-50-12-3SF, 240 Volt, 3 phase.All models available in 208/240/277 and 480 volt.(A) ASME Construction available.For ASME construction add “A” to the model number.Example: M-II-50A-12-3SF, 240 Volt, single phase.NOTE: Refer to pages 130/131 for technical information and pages 150/151 for GPH recovery information. HOT

COLD45°

15 1/8"

22 1/8"19 1/2"

HOT

COLD 52°

13"

56°T & P 47°

T & P

HOT

COLD 58°

12"

18 1/2"

63°T & P

M-II-50 M-II-80 M-II-120

Surface and Immersion Thermostat ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES

page 144

page 145

Page 74: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

T&P

DRAIN

HI/LOWPRESSURE

B

A

E

ANODE

T&P VALVE

OUTLET

F

D

C

CLEANOUTNOTAVAILABLEON 6/12 GAL.

Photo of30A-36-3

Commercial ElectricASME Models

146/147

Standard Features:l Immersion Thermostat with

Contactors - Immersion Type Thermostat for Accurate Temperature Control from Positive Off up to 180°F

l ASME Code Constructionl Vitraglas® Liningl Commercial Hydrojet® Sediment

Reduction Systeml Completely Pre-Wired With Pressure

Lug Terminal or Fuse Block Eliminating the need for Splicing or Taping Wires

l Dielectric Fittingsl Non-CFC Foam Insulation 2" For 6-40 Gallon 3" For 50-119 Gallon

l Protective Magnesium Anode Rodl Handhole Cleanout Opening (20 thru

120 Gallon Models Only)l T&P Relief Valvel Low Restriction Brass Drain ValveOptions:l Low Water Cut-Off Switchl Safety Door Interlockl High and Low Pressure Limit Switchesl Alarm Hornl Temperature and Pressure Gaugel Time Delay Step Sequences (24kW

and Above)l NSF Construction

39183636818181

6122030405080119

6A-kW-312A-kW-320A-kW-330A-kW-340A-kW-350A-kW-380A-kW-3120A-kW-3

55 33171/428

271/238

481/4473/4601/4641/2

16162020202426

301/4

1728273838

461/2461/2501/4

181/16

2815/16

28401/4501/2503/8617/8665/16

83118145180220270335430

61/461/461/461/461/4666

181/4 29

281/239

491/4491/4613/466

ELECTRIC MODELS A

Floor to Heater

Top

B

JacketDia.

GPHRecovery

90°F Rise*

1st Hour**DeliveryRating

Max.kW Input

Gal.Cap.

ModelNumber

C

Floor to Top of

Control Box

D

Floorto HWOutlet

E

Floorto T&PValve

F

Floorto CWInlet

3/43/43/43/43/411/211/211/2

WaterConn.

Approx.Shipping

Weight (lbs)

COLDCOLD

HOT

78°

10"

14 1/2"

20A, 30A, 40A

13"

HOT

87°

8"

12A

87°78°

COLD

T & P T & P T & P

DRAIN

HOT

75°

8"

13"

6A

75° DRAINDRAIN

HOT

COLD45°

15 1/8"

22 1/8"

120A

19 1/2"

HOT

COLD 52°

13"

80A

56°T & P 47°

T & P

HOT

COLD 58°

12"

18 1/2"

50A

63°T & P

NOTE: Refer to pages 150/151 for GPH recovery information.

ASME ModelsDIMENSIONS IN INCHES

page 146

page 147

Page 75: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

TEMPERATURE& PRESSURERELIEF VALVEHOT

WATEROUTLET

HANDHOLECLEANOUT

DRAIN

COLDWATERINLET TOP VIEW

6 1/4"

D

HINGED DOORTO ELECTRICALCOMPARTMENT

B

E

A

C

Photo ofVR-200-36

Commercial ElectricBrute Vertical Round Models

148/149

Standard Features:l 150 psi ASME Code Tankl Lifting Lug Accessl Incoloy® Heating Elementsl Vitraglas® Liningl Internal Fusingl Galvanized Steel Jacketl Magnesium Anode Rodsl Immersion Thermostatl Manual Reset High Limitl Hinged Door with

Keyed Lockl Temperature and Pressure

Relief Valvel Channel Iron Skid Basel Hand Hole Cleanoutl 180°F Operationl Three Year Limited Warrantyl Meets or Exceeds ASHRAE 90.1b

(Current Edition)

Optional Equipment Features:l Low Water Cut-Offl Pilot Lightsl Manual Limiting Switchesl Alarm Belll Low or High Pressure Switchl Time Clock (7 Day or 24 Hour)†

l Safety Door Interlockl Temperature and Pressure Gaugel Manhole Cleanout (250 Gallons

and Larger)l Electronic Sequencer (36kW

& Higher)l Shunt trip disconnect†

l BMS Relay†Separate mounting

150200250300400500600

VR-150-kWVR-200-kWVR-250-kWVR-300-kWVR-400-kWVR-500-kWVR-600-kW

383/4 383/4 403/4 463/4523/4 523/4 603/4

32323440464654

73/473/4191/221

221/2221/2241/2

65075011651350159017002010

16171720232327

651/2 789280809292

ELECTRIC MODELS D

Depth

90162162162162162162

Max.kW Load**

Gal.Cap.

ModelNumber

B

Jacket

Diameter

A

Floor toTop ofHeater

C

Floor toCold Water

Inlet

E

Back of Heaterto Cold

Water Inlet

11/211/211/2222

21/2

WaterConn.

Approx.Shipping

Weight (lbs)

NOTE: Refer to pages 150/151 for GPH recovery information.** Vertical Round models above 90kW at 208V, 240V or 380V, and 162kW at 400V, 415V or 480V, exceed the capacity of a single control panel and may require multiple control panels. Consult the factory for specific details and optional construction.

Brute Vertical Round ModelsDIMENSIONS IN INCHES

page 148

page 149

Page 76: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

kWInput

Gallon Per Hour Recovery Capacities

40°F1

1.52

2.53

3.54

4.55

5.56912

13.515182427

10.315.520.725.831.136.241.446.551.756.962.193.1124140155186248279

60°F6.910.313.817.220.724.127.631.134.537.941.462.18393103124165186

90°F4.66.99.211.513.816.118.420.723.125.327.641.455626983110124

100°F4.16.28.310.312.414.516.518.620.722.724.837.25056627499112

140°F2.94.45.97.48.910.311.813.314.716.217.726.5354044537180

Commercial ElectricGPH Recovery Table for kW Input

150/151

kWInput

Gallon Per Hour Recovery Capacities

40°F3036455481144162180225270360396450540630720900

310372465558838148916751861232627923722409446535583651474449306

60°F20724831037255899311171241155018612482273031023722434349636204

90°F138165207248372662744827103312411654182020682482289533094136

100°F12414918622333559667074493111171489163818612233260629783722

140°F891061331602394254795326657981063117013291595186121272659

GPH Recovery Table

page 150

page 151

Page 77: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

DA F

EG

C

B

D DA

F

F

E EG G

C C

B

A

B

POTABLECONNECTIONS

ANODE RODS(TYPICAL)

(TYPICAL)ANODE RODS

(TYPICAL)

POTABLECONNECTIONS

(TYPICAL)

Photo of SW-65C-5

SW-65C-5SW-80C-5SW-120C-5

DA F

EG

C

B

D DA

F

F

E EG G

C C

B

A

B

POTABLECONNECTIONS

ANODE RODS(TYPICAL)

(TYPICAL)ANODE RODS

(TYPICAL)

POTABLECONNECTIONS

(TYPICAL)

CommercialPowerStor Series® Single-Wall Indirect Models

152/153

l Heat Exchanger—Single-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil

l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—1" NPT true dielectric

fittings l 1" NPT Connection for Boiler Supply

and Returnl 2" Non-CFC Foam Insulationl Immersion Type Aquastat—Accurate

temperature controll Three Protective Aluminum Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel 5 Year Tank and Heat Exchanger Warrantyl AHRI Certified Water Heater Ratings

l Stand-by Heat Loss Is Less than 1/2°F per Hour (ASHRAE 90.1b Current Standard)

32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000

5873114

SW-65C-5SW-80C-5SW-120C-5

2224

281/4

591/459

621/2

59 1/8483/858

59 3/850

603/459 5/8493/4581/2603/4633/46811/16

531/8527/8553/4

60593/4631/4

273300422

473/4473/4483/4

A

Floorto FlueConn.

C

Floor toT&P

Conn.

A

Floor toHeater

Top

B

JacketDia.

InputBTU/Hr.

GallonCapacity

ModelNumber

D

Floor toWaterConn.

53/853/863/8

E

Floor toExchanger

Outlet

F

Floor toExchanger

Inlet

111/2111/2111/2

G

Floor to Aquastat

Approx.Shipping

Weight (lbs)

ModelNumber 140°F 115°F

DOE Water Heater Performance

SW-65C-5SW-80C-5SW-120C-5

140°F 115°F

Maximum FirstHour Rating

(Gal.) @

534546583

820834871

ApproximateBoiler OutputNeeded for

Rating (BTU/Hr.)

Approximate BoilerOutput Needed

For Ratings(BTU/Hr.)

420,000420,000420,000

55,00055,00055,00055,000

ModelNumber

AHRI Water Heater Ratings

SW-65C-5SW-80C-5SW-120C-5

140°F 115°FFirst HourDelivery

405415445

ContinuousDraw Rating

@ 135°F(Gal./Hr.)

Approximate BoilerOutput Needed

For Ratings(BTU/Hr.)

370370370

HeatSource

Flow Rate(Gal./Min.)

14.014.014.0

HeatReq.Rate

(BTU/Hr.)245,000245,000245,000

StandbyHeat Loss(°F/Hr.)

0.70.60.4

55,00055,00055,00055,000Note: Pressure Drop across commercial models is 2.3

ft w.c. at 12 gpm for 200°F Boiler Supply.Note: These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180°F boiler water supply temperature. Other results will be obtained under different conditions.

PowerStor Series® Single-Wall Indirect ModelsDIMENSIONS IN INCHES

page 152

page 153

Page 78: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofM-3-ST80R5

B

A

FRONT REAR

DC

EF

GH

J

B

A

FRONT REAR

DC

EF

GH

J

CommercialJacketed Storage Tank Models

154/155

l Vitraglas® Liningl Optional ASME Construction Availablel 2" Non-CFC Foam Insulationl Water Connections—2" NPT true

dielectric fittings (M-3-ST120R5A and M-3-ST200R5A Have 21⁄2" Connections)

l Rear Connection—2" NPT Spud allows for rear water connection (M-3-ST120R5 and M-3-ST120R5A only)

l Hand Hole Cleanout (M-3-ST120R5 Has Optional Hand Hole Cleanout)

l Two Magnesium Anode Rodsl Steel Tankl 1" Side T&P Valve Openingl 3/4" NPT Aquastat Connectionl Low Restriction Brass Drain Valve

32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000

8080119119200

M-3-ST80R5M-3-ST80R5A*M-3-ST120R5M-3-ST120R5A*M-3-ST200R5A*

2424282832

583/4583/4621/2621/277

59 1/8483/858

59 3/850

603/459 5/8493/4581/2603/4633/46811/16

521/2521/2553/4553/466

593/4593/4631/2631/278

192278312366633

91/491/491/291/2111/4

A

Floorto FlueConn.

C

Floor toT&P Valve

A

Floor toHeater

Top

B

JacketDia.

InputBTU/Hr.

GallonCapacity

ModelNumber

D

Floor toHot Water

Conn.

——91/291/2—

J

Floor toRear Water

Conn.

2(F&T)2(F&T)

2(F&T), 2(R)2 1/2(F&T), 2(R)

2 1/2(F&T)

WaterConn.Size†

141/4141/4141/2141/2161/4

E

Floor to Aquastat

Top Circ. Conn.

F

Floor to Bottom

Circ. Conn.

43/443/455

63/4

G

Floor toDrain Valve

71/471/4—71/291/4

H

Floor toHand Hole Cleanout

Approx.Shipping

Weight (lbs)

HOT OUTLET

HOT OUTLET

COLD INLET

COLD INLET

COLD INLET

SHUTOFFVALVE

SHUTOFFVALVE

SHUTOFFVALVE

CHECKVALVECHECK

VALVE

T & PT & P

T & P

T & PT & P

T & P

THERMOSTAT THERMOSTAT AQUASTAT

RECIRCULATINGLOOP

ALL BRONZECIRCULATOR ALL BRONZE

CIRCULATORALL BRONZECIRCULATOR

HH

C

BOILERTANKLESSCOIL

RECIRCULATINGLOOP

ALL BRONZECIRCULATOR

ALL BRONZECIRCULATOR

AQUASTATAQUASTAT

HOT OUTLET

* Meets ASME Code† (F) = Front water connections (R) = Rear water connections (T) = Top water connections

Jacketed Storage Tank ModelsDIMENSIONS IN INCHES

page 154

page 155

Page 79: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Photo ofNV310JG5A

CommercialLarge Volume Jacketed Storage Tank Models

156/157

l Vertical or Horizontal Constructionl Water Connections—Two female 3" NPT fittings are located on the front for

ease of service and installation l ASME Constructionl Available with Vitraglas® Lining, Double Vitraglas® Lining, Epoxy Lining, or

Stainless Steel Tankl Hydrojet® HC—Optionall 2" High Density Insulationl Protective Magnesium Anode Rod(s)l ASME Tested and Certified to 125 psil Designed for Storage of Potable Water up to 180°Fl 5 Year Tank Warranty

A

C

B

Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles

• Extra Tappings (1"- 4") Sizes must be specified when ordering

• Flanged Connections (3"-10")• Stainless Steel Construction• 150 psi (add suffix -5)• Hydrojet® HC (add suffix -1)

Manway inspection port is provided as standard equipment on epoxy lining. Options must be specified when ordering

page 156

page 157

Page 80: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

175210240280285310320340360415435453465

N†175J*5AN†210J*5AN†240J*5AN†280J*5AN†285J*5AN†310J*5AN†320J*5AN†340J*5AN†360J*5AN†415J*5AN†435J*5A N†453J*5AN†465J*5A

718393107808611993981108989122

438493539603667710658760796881917942967

843108111471410169022292749

34343434404034404040464640

B

JacketDia.

30363642484848

Bare TankDia.

Actual U.S.Capacity

Gal.

193229260303318344340375397449486504502

Nominal U.S.Capacity

Gal.Model

NumberVert.

Height

677989103768211589941068588118

Horiz.Length

A

191/2191/2191/2191/22121

191/2212121

221/2221/221

191/22121

221/2242424

C

Floor to Inlet

21/221/221/221/221/221/221/221/221/221/233

21/2

Hot WaterOutlet Conn.

Approx. ShippingWeight (lbs)

@125 PSI

CommercialLarge Volume Jacketed Storage Tank Models

158/159

Vertical and Horizontal ModelsDIMENSIONS IN INCHES

500505515575580645675720765790840875104012451530

N†500J*5AN†505J*5AN†515J*5AN†575J*5AN†580J*5AN†645J*5AN†675J*5AN†720J*5AN†765J*5AN†790J*5AN†840J*5AN†875J*5AN†1040J*5AN†1245J*5AN†1530J*5A

8110113411392125104137116147128107149124148

117610171053111713101217145613171602140017481776200333263541

843108111471410169022292749

524640465246524652465258526464

B

JacketDia.

30363642484848

Bare TankDia.

Actual U.S.Capacity

Gal.

572558555630658702752774846846940981112813951689

Nominal U.S.Capacity

Gal.Model

NumberVert.

Height

779713010988121100133112143124103145120144

Horiz.Length

A

24221/221

221/224

221/224

221/224

221/224

271/2242927

191/22121

221/2242424

C

Floor to Inlet

33

21/2333333333333

Hot WaterOutlet Conn.

Approx. ShippingWeight (lbs)

@125 PSI

* = Tank Lining/ConstructionG = Vitraglas®

D = Double Vitraglas®

E = EpoxyS = Stainless Steel Example of full model number when ordering (NV240JG5A)

† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.

Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining

Vertical and Horizontal ModelsDIMENSIONS IN INCHES

page 158

page 159

Page 81: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

CommercialLarge Volume Unjacketed Storage Tank Models

160/161

l ASME Constructionl Available with Vitraglas® Lining, Double Vitraglas® Lining, Epoxy Lining, or Stainless Steel Tankl Hydrojet® HC—Optionall Magnesium Anode Rod(s)—For protection and longer service lifel ASME Tested and Certified to 125 psil Red Oxide Primer—Completely covers exterior of tankl 6" Skirt Height (Vertical Tank) Allows for Easier Access to Areas Under the Tankl Lifting Lugsl Designed for Storage of Potable Water up to 180°Fl 5 Year Tank Warranty

A

C

B

E

E

Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles

• Extra Tappings (1"- 4") Sizes must be specified when ordering

• Flanged Connections (3"-10")• Stainless Steel construction• 150 psi (add suffix -5)• Hydrojet® HC (add suffix -1)

Manway inspection port is provided as standard equipment on epoxy lining. Options must be specified when ordering

page 160

page 161

Page 82: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

175210240280285310320340360415435453465500505515575580

N†175N*5AN†210N*5AN†240N*5AN†280N*5AN†285N*5AN†310N*5AN†320N*5AN†340N*5AN†360N*5AN†415N*5AN†435N*5AN†453N*5AN†465N*5AN†500N*5AN†505N*5AN†515N*5AN†575N*5AN†580N*5A

677989103768211589941068588118779713010988

3033473834335505274765695596716958057439288748158631045

843108111471410169022292749

303030303636303636364242364842364248

B

JacketDia.

30363642484848

Bare TankDia.

Actual U.S.Capacity

Gal.

193229260303318344340375397449486504502572558555630658

Nominal U.S.Capacity

Gal.Model

NumberVert.

Height

63758599457811185901028151114735112610584

Horiz.Length

A

171/2171/2171/2171/21919

171/2191919

201/2201/21922

201/219

201/222

191/22121

221/2242424

CFloor

to Return Conn.

21/221/221/221/221/221/221/221/221/221/233333

21/233

DHot Water

OutletConn.

111111111111111111

E

DrainValve

Approx. ShippingWeight (lbs)

@125 PSI

CommercialLarge Volume Unjacketed Storage Tank Models

162/163

Vertical and Horizontal ModelsMeet or exceed ASHRAE 90.1b (current standard)DIMENSIONS IN INCHES

64567572076579084010401340182021052395270031153530404541205695

N†645N*5AN†675N*5AN†720N*5AN†765N*5AN†790N*5AN†840N*5AN†1040N*5AN†1340N*5AN†1820N*5AN†2105N*5AN†2395N*5AN†2700N*5AN†3115N*5AN†3530N*5AN†4050N*5AN†4120N*5AN†5695N*5A

121100133112143124145153168192216174198222192256262

9471173103113011101142816522182311035163922385143384825600955167994

843108111471410169022292749

4248424842484854606060727272847284

JacketDia.

30363642484848

Bare TankDia.

Actual U.S.Capacity

Gal.70275277484684694011281457198322762570296133843807446244066141

Nominal U.S.Capacity

Gal.Model

NumberVert.

Height1179612910813912014114716818621016819221693250256

Horiz.Length

A B C D E

201/222

201/222

201/22222

251/2272727303030333033

191/22121

221/2242424

Floorto Return

Conn.33333333333333333

Hot WaterOutletConn.

1111111

11/211/211/211/211/211/211/211/211/211/2

DrainValve

Approx. ShippingWeight (lbs)

@125 PSI

Example of full model number when ordering (NV175NG5A)

* = Tank Lining/ConstructionG = Vitraglas®

D = Double Vitraglas®

E = EpoxyS = Stainless Steel

† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.

Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining

Vertical and Horizontal ModelsDIMENSIONS IN INCHES

page 162

page 163

Page 83: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

CommercialLarge Volume Vertical Topcoat Storage Tank Models

164/165

l ASME constructionl Bradford White tanks with sprayed-on rigid insulation with acrylic topcoat exceeds ASHRAE 90.1

requirements with 2.25" of high-density polyurethane foam with an “R” value of R-16. SPF meets requirements for California Title 24. Bradford White spray foam insulation has the best fire spread rating with a class I foam with less than a 25-flame spread rating suitable for boiler room applications.

l The 100% acrylic topcoat is formulated for applications over spray polyurethane foam and is designed to withstand extreme weather and a full range of environmental conditions.

l The two component polyurethane foam is applied at ambient temperatures, directly to the vessel in the desired thickness. The 2-coat topcoat is then applied from a high-pressure spray gun and allowed to dry between applications.

l Alternative for insulated and steel jacketl Any tank size or shape can be insulatedl Field repairable

A

C

B

E

E

Spray Polyurethane Foam: Specific Gravity: 1.17 – 1.19Viscosity: 800 – 1300Density: @ 2” 2.10 – 2.35 @ 4” 1.88 – 1.99Closed Cell Content: >90%K-Factor, initial: 0.155 – 0.170Permeance: 2.91 (perms) 2.99 (perm inch)Dimensional Stability: +3.3 to +8.2 - Dry Age 28 days (158°F, Dry) -0.37 to –0.96 – Freeze 14 day (-20°F)Flame Spread: 25 - ASTM E-84Smoke Development: 450R Value: 7.2/ inch Max. Thickness: 4"

Acrylic Coating: Topcoat: 2 coats white, 25 milsTexture: SmoothGrade: Spray or RollBase: 100% AcrylicSolids by weight: 66% (+/-3) Solids by volume: 55% (+/-3)Weight per gallon: 11.65 (+/-.2)Tensile Strength: 300 psi (+/-25)Elongation: 260% (+/-25)Durometer hardness: 62 Shore A (+/-2)Tear Resistance: 85 lbs/ in.Permeance: 11 U.S. Perms @ 20 milsViscosity: 110 K.U. (+/-8)Codes/ Approvals: Energy Star, ICC, UL, ASTM D6083Reflectivity: New 85%, Aged 78%Emmisivity: .89

page 164

page 165

Page 84: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

175210240280285310320340360415435465500515575580645

N†175T*5AN†210T*5AN†240T*5AN†280T*5AN†285T*5AN†310T*5AN†320T*5AN†340T*5AN†360T*5AN†415T*5AN†435T*5AN†465T*5AN†500T*5AN†515T*5AN†575T*5AN†580T*5AN†645T*5A

69819110576841179196108871207913211190123

3033473834335505274765695596716957439288158631045947

843108111471410169022292749

3535353541413541354147415341475347

B

JacketDia.

30363642484848

Bare TankDia.

Actual U.S.Capacity

Gal.193229260303318344340375397449486502572555630658702

Nominal U.S.Capacity

Gal.Model

NumberVert.

Height65778710145801138792104831167512810786119

Horiz.Length

A

171/2171/2171/2171/21919

171/2191919

201/2192219

201/222

201/2

191/22121

221/2242424

CFloor

to Return Conn.

21/221/221/221/221/221/221/221/221/221/2333

21/2333

DHot Water

OutletConn.

11111111111111111

E

DrainValve

Approx. ShippingWeight (lbs)

@125 PSI

CommercialLarge Volume Vertical Topcoat Storage Tank Models

166/167

Vertical and Horizontal Energy Saver ModelsDIMENSIONS IN INCHES

67572076579084010401340182023953115353041205695

N†675T*5AN†720T*5AN†765T*5AN†790T*5AN†840T*5AN†1040T*5AN†1340T*5AN†1820T*5AN†2395T*5AN†3115T*5AN†3530T*5AN†4120T*5AN†5695T*5A

102135114145126147153168216198222256262

1173103113011101142816522182311039224338482555167994

843108111471410169022292749

53475347535359656577777789

B

JacketDia.

30363642484848

Bare TankDia.

Actual U.S.Capacity

Gal.

75277484684694011281457198325703384380744066141

Nominal U.S.Capacity

Gal.Model

NumberVert.

Height

98131110141122143147168210192216250256

Horiz.Length

A

22201/222

201/22222

251/2272730303033

191/22121

221/2242424

CFloor

to Return Conn.

3333333333333

DHot Water

OutletConn.

111111

11/211/211/211/211/211/211/2

E

DrainValve

Approx. ShippingWeight (lbs)

@125 PSI

* = Tank Lining/ConstructionG = Vitraglas®

D = Double Vitraglas®

E = EpoxyS = Stainless Steel

† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.

Example of full model number when ordering (NV240TG5A)Note: Please be advised that all tank sizes are available for this topcoat process.

Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles

• Extra Tappings (1"- 4") Sizes must be specified when ordering

• Flanged Connections (3"-10")• Stainless Steel construction• 150 psi (add suffix -5)• Hydrojet® HC (add suffix -1)

Manway inspection port is provided as standard equipment on epoxy lining. Options must be specified when ordering

Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining

Vertical and Horizontal ModelsDIMENSIONS IN INCHES

page 166

page 167

Page 85: PRODUCT POCKET CATALOG

Bradford White Product Pocket Catalog - 2016

FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.

Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.

www.bradfordwhite.com

Warranty Information 168/169

Some states do not allow limitations on warranties. See copy of the Warranty included with the heater. *Heat Exchanger Only **10 year parts warranty on warranty upgrade kit models only. †Heater Body Element Assembly.

Limited TankWarranty

Residential Gas ModelsAtmospheric Vent High EF Models ............................................................. 6 or 10 Year 6 or 10 Year**Atmospheric Vent Damper Models ............................................................. 6 or 10 Year 6 or 10 Year**Residential High EF Models........................................................................ 6 or 10 Year 6 or 10 Year**Residential High Performance Models ........................................................ 6 Year 6 YearResidential TTW® High Performance Models .............................................. 6 Year 6 YearResidential Extra Recovery Models ............................................................ 6 or 10 Year 6 or 10 Year**Residential Upright Models ........................................................................ 6 or 10 Year 6 or 10 Year**Residential Power Vent Models .................................................................. 6 or 10 Year 6 or 10 Year**Residential Power Direct Vent Models ........................................................ 6 or 10 Year 6 or 10 Year**Residential Direct Vent Models .................................................................. 6 or 10 Year 6 or 10 Year**Residential Ultra Low NOx Models ............................................................. 6 or 10 Year 6 or 10 Year**Residential eF Series® Models ................................................................... 6 or 10 Year 6 or 10 Year**Residential Manufactured Home Models .................................................... 6 or 10 Year 6 YearResidential Infiniti Tankless Models ........................................................... 12 Year* 5 YearResidential Heat Pump ModelsResidential AeroTherm™ Heat Pump Models .............................................. 10 Year 10 YearResidential Electric ModelsResidential High Efficiency, Upright, Lowboy Models ................................. 6 or 10 Year 6 or 10 Year**Residential Utility, Wall Hung Models ......................................................... 6 or 10 Year 6 or 10 Year**Residential Kwickshot® Models .................................................................. 10 Year† 1 YearSolar ModelsResidential Solar Models ........................................................................... 6 or 10 Year 6 YearResidential Hydronic/Space HeatingResidential Combi1™ Models ..................................................................... 10 Year 6 YearResidential Combi2™ Models ..................................................................... 10 Year 6 YearResidential Indirect ModelsResidential PowerStor Series® Model ......................................................... Limited Lifetime 6 YearResidential PowerStor2 Series® Models ..................................................... Limited Lifetime 6 YearResidential PowerStor Series® SS Models .................................................. Limited Lifetime 6 YearResidential Storage TankResidential AST Models ............................................................................. 6 Year 6 Year

Commercial Gas ModelsLight Duty Commercial High Performance Models ................................... 3 year 1 YearLight Duty Commercial TTW® High Performance Models ......................... 3 year 1 YearLight Duty Commercial Upright Models .................................................... 3 year 1 YearLight Duty Commercial Power Vent Models ............................................. 3 year 1 YearLight Duty Commercial Power Direct Vent Models ................................... 3 year 1 YearLight Duty Commercial Direct Vent Models .............................................. 3 year 1 YearLight Duty Commercial Ultra Low NOx Models ......................................... 3 year 1 YearCommercial Flue Damper Models ............................................................ 3 year 1 YearCommercial Induced Draft Models ........................................................... 3 year 1 YearCommercial Millivolt Models .................................................................... 3 year 1 YearCommercial eF Series® Ultra High Efficiency Models ............................... 3 year 1 YearCommercial Ultra Low NOx Models .......................................................... 3 year 1 YearCommercial Electric ModelsLight Duty Commercial Upright, Lowboy Models ...................................... 3 year 1 YearLight Duty Commercial Utility, Wall Hung Models ..................................... 3 year 1 YearCommercial Medium Duty Models ........................................................... 3 year 1 YearCommercial Surface Mount, Immersion Models ....................................... 3 year 1 YearCommercial ASME Models ....................................................................... 3 year 1 YearCommercial Brute Models........................................................................ 3 year 1 YearCommercial Indirect-FiredCommercial PowerStor® Models .............................................................. 5 year 1 YearCommercial Storage TankCommercial Jacketed Models .................................................................. 5 year 1 YearCommercial Bare Glass Coated Models ................................................... 5 year 1 YearCommercial Jacketed Large Volume Models............................................ 5 year 1 YearCommercial UnJacketed Large Volume Models ....................................... 5 year 1 YearCommercial Top Coat Large Volume Models ............................................ 5 year 1 Year

Limited PartsWarranty

Limited TankWarranty

Limited PartsWarranty

S = 1998 T = 1999 W = 2000 X = 2001 Y = 2002

Z = 2003 A = 2004 B = 2005 C = 2006 D = 2007

E = 2008 F = 2009 G = 2010 H = 2011 J = 2012

K = 2013L = 2014M = 2015N = 2016

K = 1993 L = 1994 M = 1995N = 1996 P = 1997

841/2841/2841/2731/2731/2731/2731/2731/2841/2841/2841/2841/2841/2

493/4 / 563/8 383/4

493/4 / 551/450 / 565/841 / 471/4511/2 / 5850 / 567/8

401/2 50 / 553/4501/2 / 58

33595/16

Tank Type Serial Number IdentificationFIRST LETTER - YEAR OF MANUFACTURE

A = JANUARYB = FEBRUARYC = MARCHD = APRIL

Example:FC12345678 = MARCH, 2009 ProductionNA12345678 = JANUARY, 1996 Production

Bradford White uses a 20-year letter designation rotation in serial numbers. Therefore, please be aware that water heaters manufactured 20 years apart will have the same serial number “letter year” designation.(i.e. A = 2004 and 1984).

E = MAYF = JUNEG = JULYH = AUGUST

J = SEPTEMBERK = OCTOBERL = NOVEMBERM = DECEMBER

SECOND LETTER - MONTH OF MANUFACTURE

page 168

page 169