product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler...

24
INSTALLATION & OPERATION Ness GSM Dialler V2 Product part number 106-097 • Full time GSM pathway for alarm diallers to communicate in the absence of a land line. Compatible with all Ness control panels and most other brands. Connect a telephone handset and make phone calls via GSM. Three alarm inputs programmable to send SMS alert messages. Three alarm outputs controllable via SMS. Zero programming for use with alarm panels - simply plug and go. Easy programming via handset and SMS if you choose to use SMS features. Antenna with magnetic base supplied - long antenna cable allows the unit to be installed in a secure housing. REV 2.1

Transcript of product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler...

Page 1: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & operatIon

Ness GSM Dialler V2

product part number 106-097

• Full time GSM pathway for alarm diallers to communicate in the absence of a land line.

• Compatible with all Ness control panels and most other brands.

• Connect a telephone handset and make phone calls via GSM.

• Three alarm inputs programmable to send SMS alert messages.

• Three alarm outputs controllable via SMS.

• Zero programming for use with alarm panels - simply plug and go.

• Easy programming via handset and SMS if you choose to use SMS features.

• Antenna with magnetic base supplied - long antenna cable allows the unit to be installed in a secure housing.

REV 2.1

Page 2: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

NESS GSM DiAllER iNSTAllATioN & opERATioN NoTES, Revision 2.1Document part Number 890-399

For the products: 106-097 Ness GSM Dialler without SiM version HW1.1 SW1.1 MW1.5 or later.

www.ness.com.au

CopyRiGHT NoTiCE

All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Ness.

Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement.

© 2011 Ness Corporation pty ltd ABN 28 069 984 372

National Customer Service Centre ph 1300 551 991

SyDNEy ph 02 8825 9222 [email protected]

MElBouRNE ph 03 9875 6400 [email protected]

BRiSBANE ph 07 3399 4910 [email protected]

pERTH ph 08 9328 2511 [email protected]

ADElAiDE ph 08 8152 0000 [email protected]

Page 3: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

Contents

overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Rear panel & Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Data port connections, inputs/outputs . . . . . . . . . . . . . . . . . . . . . . . . . . .6, 7

installing a SiM card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Display & lEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

installation Checklist / important Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

programmIng

programming & operation Commands Summary . . . . . . . . . . . . . . . . . . . .11

How to Enter program Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Admin phone Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Enquire all Admin phone Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Area Code / phone Number prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Alert Recipients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Enable Alarm inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

program the input Alarm/Restoral Message . . . . . . . . . . . . . . . . . . . . . . . .18

program the Buzzer output duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Set The Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Check Current Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Status Query . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Check GSM Signal Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Version Query . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

operatIon

Arm & Disarm the GSM unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Control The outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Page 4: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

4

GSM comms to central station

No lANDliNE REQuiRED

GSM unit

Control panel / Diallerfor alarm monitoring

SMS Messages to Mobile phones

SMS commands to control outputs

optional handset for programming or making calls

overvIew

pRoDuCT VERSioN NoTES

This manual is for use with Ness GSM Dialler with software version 1.1 although some of the features described are also available in units with V1.0 software.

To verify that your GSM Dialler is compatible with the manual, try entering program mode as described on page 12.

- if you can enter program mode using the default installer code of 123456, then the features described in this manual are available.

- if the default installer code does not give you access, then: A/ The GSM Dialler is an older version without the extended features. or, B/ The GSM Dialler may be a recent version and the installer code has been

changed by the installer or the owner. (The installer code cannot be reset if it is lost.)

Page 5: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

5

rear panel & ConneCtIons

TElConnect RJ11 lead from alarm panel or handset.

poWER SWiTCHMust remain on

poWER iNpuT12VDC from supplied plug pack or from control panel supply. 550mA average draw during a call. peak of >1A is required.

DB15 DATA poRTinputs / outputs

antenna ConneCtIon

ANTENNA SoCkET

Connect the antenna cable to the GSM unit and place the antenna as far as possible from the unit. The antenna is supplied with a 5m cable to allow positioning of the antenna for best signal reception. Excess cable should be kept straight and not be coiled to prevent radiant interference.

5m cable

Antenna supplied with Magnetic base

Page 6: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

6

Data port ConneCtIons

pIn

Colour(if i/o cable supplied) DesCrIptIon

1 Black GND

2 Not used.

3 Not used.

4 Red Buzzer output +ve

5 yellow Buzzer output –ve

6 Not used.

7 BlueAC Fail output, +ve output when mains power is off and unit is running off the internal battery.

8 Brown +7.2VDC output, use as reference for inputs and output trigger only.

9 Green 1 Alarm input 1 3 x alarm inputs can be programmed to send alert messages by SMS. Apply +7.2V (from pin 8) to send Alarm, remove the voltage to Restore.10 Green 2 Alarm input 2

11 Green 3 Alarm input 3

12 White 1 output 1

3 x open collector outputs can be controlled by SMS messages.

13 White 2 output 2

14 White 3 output 3

15 purple Not used.

The GSM unit may be supplied with an i/o cable for connecting alarm inputs and outputs, or use your own DB15 plug.

Page 7: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

7

ConneCtIonConnection examples for the DB15 data port.

piN 9, 10 or 11 Green1, 2 or 3

BrownpiN 8

AlARM iNpuTSNormally open switch. Close to send an alarm, open to send restoral. programming info, page 17.

BuZZER ouTpuTThe buzzer output can be programmed to trigger on alarm. Suitable for a low current sonalert or relay. programming info, pages 17, 19.

piN 5yellow

RedpiN 4

ouTpuTSopen collector outputs can be controlled by handset or SMS commands. Connect a low voltage relay. Max. current draw 200mA.Remote operation info, page 23.

White1, 2 or 3

BrownpiN 8

N/OCOMN/C

piN 12, 13 or 14

Page 8: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

8

InstallIng a sIm CarD

1. insert SiM card. observe position of the notch.

3. Slide forward to lock.

2. Close the SiM holder.

sIm CarD pInunlocked sIm card - no pIn (Any version of GSM unit) if you use an unlocked SiM card simply insert the SiM card as shown above and it is ready to use.

locked sIm card - with pIn (Applies to GSM units with software V1.1 and later)if you use a SiM card that has a piN, you must program the piN into the GSM unit as follows. A handset must be connected to the GSM unit. GSM units prior to V1.1 cannot use locked SiM cards.

1. insert the locked SiM card.2. Turn on the GSM unit.

GSM unit power switch must be off.

LOADING: >>>>>>ENTER UNLOCKCODE:

3. HANDSET Enter the 4 digit piN followed by # (eg, 1234#)

WANT TO SAVE THE CORRECT PIN:

4. HANDSET Enter: 1

PIN SAVEDSUCCESSFULLY:

5. Hang up the handset. The SiM card’s piN has now been saved.

Page 9: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

9

DIsplay & leDs

poWER lEDWhen on indicates mains and battery are connected

SiGNAl lEDSlow Flash: SiM/GSM ok.Fast Flash: SiM/GSM problem.

GSM Signal Strength

Display during power up.

Armed / Disarmedpower indicators

Display when the handset is picked up.Dial a phone number or start program mode.

The phone number is displayed during dialling.

LOADING: >>>>>>

16 : 55 : 11NESS GSM

ENTERSETTING................

num: 98756400

Page 10: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

InstallatIon & setup

10

InstallatIon CheCklIst

1. install the GSM unit in secure tamper-protected plastic housing. The Ness 101-008 housing is ideal.

2. install an active GSM network SiM card in the GSM unit. if your SiM card is piN locked see page 8.

3. Connect a standard RJ11 telephone lead from the alarm panel’s dialler to the TEl socket on the GSM unit.

4. Connect the antenna cable to the antenna socket and mount the antenna in a position at least 1m away from the GSM unit.

5. plug in the supplied 12VDC plug pack to the power socket.

6. Turn on the power switch.

7. using the signal strength bars on the lCD display as a guide, position the antenna for best signal then confirm the actual signal strength using the CSQ command, see page 21.

8. program your alarm panel as required for monitoring back to base or to a private phone.

9. Check operation by sending a test alarm.

sIm CarD FaIlureThe GSM unit continuously monitors system status and if it detects a problem with the SiM card or the network it will automatically reset (reboot) until the SiM card is detected and it has successfully logged on to the network.

gsm sIgnal testThe signal strength bars on the lCD display are intended as a guide to the presence of a GSM signal. under some circumstances the display may show signal bars but you can’t make calls. This could be caused by:• The GSM unit may not be locked on to the network. • GSM network may be temporarily unavailable.• The SiM card may have run out of credit or expired.

gsm ConneCtIvIty Can be CheCkeD by: a/ See page 21, how to check the GSM signal strength.b/ TEST uSiNG A HANDSET. if the GSM unit does not seem to connecting to the central station, test the GSM service by connecting a telephone handset and phone your own mobile phone to test that GSM is available and active.

Important notes

Page 11: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

11

programming Command summary

Description hanDset Commandsms Command(Must be sent in CApS) page

Enter program Mode [6 digit installer code]Default 123456

12

program a new installer Code 0 [new code] 12

Admin phone Numbers 1 to 8 1 to 8 [new phone] 13

Enquire all Admin phone Numbers 32 ADM? 14

Area Code / phone Number prefix 9 [prefix] 15

Enable/Disable ph Number prefix 14 1 or 0 15

program the Alert Recipients 18 [nnnnnnnn] 16

Enable Alarm input 1 24 [nnnnn] 17

Enable Alarm input 2 25 [nnnnn] 17

Enable Alarm input 3 26 [nnnnn] 17

Set the input Alarm Message uSE[n] [message] 18

Set the input Restoral Message uSC[n] [message] 18

program the Buzzer output Duration 33 [nnnnn] 19

Set The Clock SETM HH:MM:SS 20

Status Query CTC? 20

Check GSM Signal Strength 20 CSQ? 21

Version Query 13 21

Arm the GSM unit DARM 1 22

Disarm the GSM unit DARM 0 22

Control output 1 21 [nnnnn][n] Rly1 [nnnnn] 23

Control output 2 22 [nnnnn][n] Rly2 [nnnnn] 23

Control output 3 23 [nnnnn][n] Rly3 [nnnnn] 23

operation Command summary

Page 12: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

12

enter program moDeTo enter program mode, connect a telephone handset to the TEl socket on the GSM unit.

Any fixed line telephone for programming.

pick up the telephone handset and dial 123456 (default installer code)

HANDFREE...

The display will show

HANDSETin program Mode press 0 to program a new 6 digit installer code.

NEW pASSWoRD: 654321#

The display will show

program the Installer Code

To program a new 6 digit installer code. The installer code is used to access programming mode via handset.

The GSM unit is now in program Mode.To exit program mode hang up the handset.

Enter the new code followed by # (eg, 654321#)

To exit program mode simply hang up the handset.

Admin phone Number 1 must be programmed to allow sending of SMS commands to the GSM unit.

notes

take Care not to lose the Installer CoDe as It Cannot be reCovereD IF lost or Forgotten.

Page 13: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

13

relateD optIonsinput Alarm Message. page 18.input Restore Message. page 18.program the alert recipients. page 16.Enquire all Admin phone Numbers. page 14.

HANDSETin program Mode press 1 to program the Admin phone Number 1.

TEl: 0418000000 1#

program the admin phone numbers

up to 8 ADMiN phone numbers can be programmed. These are mobile phone numbers to which the GSM unit can send SMS messages, such as alarms from inputs or system messages. you can program the unit to send SMS alarms to one or all Admin numbers.

Enter the phone number followed by # (eg, 0418000000#)

To program Admin phone Numbers 2 to 8, repeat the sequence above using 2 , 3 , 4 , 5 , 6 , 7 , 8

To Delete a phone Number enter with no phone number. eg, to delete Admin Number 1,

HANDSET press 1

pRoGRAMMiNG METHoDS – HANDSET and SMS Commands.

please note that some options are programmed using a telephone handset connected to the GSM unit and other options are programmed by SMS message sent from a mobile phone.

SMS CoMMAND options are programmed by sending an SMS message from a mobile phone to the GSM unit.

the mobile phone used to send sms Commands must be programmed as admin phone number 1.

Page 14: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

14

ADM?

To display all the Admin phone Numbers by SMS.

SMS Command:

The GSM unit will send this reply message: Example.1: 04180000002:3:4:5:6:7:8:

enquire all admin phone numbersTo display all the Admin phone Numbers locally using a handset.

Each Admin phone Number will be displayed in sequence:

ADMiN:

1: 0418000000

HANDSETin program Mode press 32

relateD optIonsprogram the Admin phone Numbers. page 13.

Page 15: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

15

area Code / phone number prefixTo program prefix digits which will be automatically dialled before any phone number.

Enter the prefix (max. 4 digits) followed by # (eg, 1832#)

NEW AREA: 1832 ok

HANDSETin program Mode press 9

enable/Disable phone number prefix

use this option to enable the dialling of the phone Number prefix.

To enable the phone Number prefix press 1 To disable the phone Number prefix press 0

AREAoN&&oFF: 1

HANDSETin program Mode press 14

note: once programmed, the phone number prefix cannot be deleted only replaced by a new prefix. use the *14* option to enable and disable dialling of the prefix.

relateD optIonsprogram the Admin phone Numbers. page 13.

Page 16: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

16

HANDSETin program Mode press 18 to select the option.

SECT: 11111111 ok

program the alert recipientsThis option sets which of the 8 Admin phone Numbers will receive SMS alerts.

Enter either the digit 0 (No alert) or 1 (Send alert) for each of the 8 Admin phone Numbers, followed by #.

Example 1, to enable all Admin Numbers for alerts, press 11111111#

SECT: 11100000 ok

Example 2, to enable only Admin Numbers 1,2 & 3 for alerts, press 11100000#

relateD optIonsprogram the Admin phone Numbers. page 13.Enquire all Admin phone Numbers. page 14.

Page 17: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

17

iN1: op:1 Cl:1 Al:1CA1:0 CA2:0

alarm Input/output programmingHANDSET

in program Mode 24 to program input 1 25 to program input 2 26 to program input 3

This option enables the three alarm inputs on the DB15 port.

Enter either the digit 0 (Disable) or 1 (Enable) for the five possible actions for the input, followed by #. Note: The last two digits must always be zero.Example, to enable input 1 to send SMS Alarm and Restoral messages and turn on the audible alarm output when the input is triggered , press 24 11100#

Input 1 (pin 9)

Input 2 (pin 10)

Input 3 (pin 11)

iNpuT opTioNSop: Send SMS on Alarm (Alarm input to +12V)Cl: Send SMS on Restoral (Remove +12V from input)Al: Sound the audible alarm when input is triggeredCA1: NoT uSED must be zeroCA2: NoT uSED must be zero

Follow the same procedure for inputs 2 & 3.

relateD optIonsinput Alarm Message. page 18.input Restore Message. page 18.program Buzzer output duration. page 19.

Page 18: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

18

use[n] [message]N = input number 1, 2 or 3.[message] = up to 50 alphanumeric characters. letters and numbers only, no special characters.

Input alarm messageThis option sets the SMS text which is sent when an input is triggered.

Example, to program input 1 to send the SMS message “Garage door open” send:

uSE1 Garage door opened

SMS Command:

The GSM unit will send this reply message: uSE1 Garage door opened

relateD optIonsAlarm input/output programming. page 17.

usC[n] [message]N = input number 1, 2 or 3.[message] = up to 50 alphanumeric characters. letters and numbers only, no special characters.

Input restoral messageThis option sets the SMS text which is sent when an input is resealed.

Example, to program input 1 to send the SMS message “Garage door closed” send:

uSE1 Garage door closed

SMS Command:

The GSM unit will reply: uSE1 Garage door closed

Page 19: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

19

program the buzzer output durationTo program the Buzzer output duration on the data port pin 4.The alarm time can be between 00001 to 99999 seconds. Note that programming a duration of 00000 seconds has no effect - see page 17 for information on how to enable and disable the Buzzer output.

HANDSETin program Mode press 33

AlARM:

Example, to program buzzer duration for 5 seconds, enter 00005#

AlARM:00005

relateD optIonsAlarm input/output programming. (page 17)

Page 20: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

20

CtC?

status QueryTo check the status of the inputs, pSTN line and AC power by SMS.

SMS Command:

The GSM unit will reply, for example: AC: 1 Mains power is on. pSTN: 0 Always zero. This product does not connect to pSTN.iNpuT 1: 1 input 1 is unsealed.iNpuT 2: 0 input 2 is sealed.iNpuT 3: 0 input 3 is sealed.

set the Clock

astm

Check Current timeCheck the GSM unit’s internal time by SMS.

SMS Command:

The GSM unit will reply, for example: TiME - 15:52:49

setm hh:mm:ss

program the internal clock by SMS. The time is set in 24HR format.

Example, to program the time to be 3:30pM, send SETM 15:30:00

SMS Command:

The GSM unit will reply, for example: SETM-ok

Page 21: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

programmIng

21

HANDSETin program Mode press 13

HW: 1.1ver SW: 1.1ver MW: 1.5ver

The display will show, for example.

version QueryTo check the software and hardware version by handset.

CsQ?

Check gsm signal strength

Check the GSM signal strength by SMS or handset.

SMS Command:

The GSM unit will reply, for example: CSQ=<28>0=poor signal, 31=Best signal, 99=unknown or not detectable

HANDSETin program Mode press 20

CSQ <28> Example signal strength.

The display will show the signal strength.0=poor signal, 31=Best signal, 99=unknown or not detectable

Page 22: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

operatIon

22

arm/Disarm the gsm unitThe GSM unit must be armed to enable the alarm inputs to trigger, send SMS alerts and turn on the Buzzer output.

ARM & DiSARM:oN&&oFF:

HANDSETin program Mode press 10

To ARM press 1

To DiSARM press 0

DARM 1

To Arm/Disarm the GSM unit by SMS.

SMS Command:

The GSM unit will send this reply message: ARM

To ARM

DARM 0SMS Command:

To DiSARM

The GSM unit will send this reply message: DiSARM

Armed

16 : 55 : 11NESS GSM

Disarmed

16 : 55 : 11NESS GSM

lCD InDICatIon oF arm/DIsarm

To Arm/Disarm the GSM unit by handset.

Page 23: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

operatIon

23

rly[n] [time]N = output number 1, 2 or 3.[time] = relay on time in seconds between 00000 and 99999 seconds.To toggle outputs, send the text oN & oFF instead of a time value. See the example below.

remote Control outputs by smsThis allows you to turn outputs on by SMS. This can be used to arm or disarm an alarm control panel, turn on lights at the premises and control almost any device that can be switched on by a relay.

Example, to program output 1 to stay on for 5 seconds when triggered, send: Rly1 00005

SMS Command:

The GSM unit will reply: Rly1- 00005

the mobile phone used to send sms Commands must be programmed as admin phone number 1. see page 13.

The three outputs are open Collector and can sink 200mA Max. use with external relays such as the Ness 100-282 Basic Relay (optional).

Control outputs by handset

HANDSETin program Mode 21 to control output 1

22 to control output 2 23 to control output 3

Example, to activate output 1 for 5 seconds and send a SMS message when the output has turned off, enter 000051#

Rly1:00005 RE:1

The options for RE: are.0 = Do not send SMS reply when the output turns off.1 = Send SMS reply when the output turns off.

Page 24: product part number 106-097 - Better Value Group€¦ · InstallatIon & operatIon Ness GSM Dialler V2 product part number 106-097 • Full time GSM pathway for alarm diallers to communicate

speCIFICatIons

24

gsm CompatIbIlIty GSM module compatible with GSM voice communications Requires an active SiM card (not supplied)

alarm panel CompatIbIlIty

Compatible with all Ness alarm diallers in Contact iD DTMF and Voice reporting formats.

operatIng voltage 12VDC plug pack supplied or from control panel supply. power supply capacity must be 1A or greater to allow for peak current draw.

Current Draw idle: 100mA, During a call: 500mA.

Internal battery Rechargeable 7.2V, 1800mAh, lithium polymer

antenna 0dB whip with magnetic base, 5m cable length

DImensIons 250 x 140 x 60mm

weIght 1.5kg

operatIng temperature 0°C to +50°C