PRODUCT CODE: A50R-1/2/3 PUBLICATION DATE: October 2016 ... · IMPORTANT NOTES: - With a hung...

2
A50R-3 For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023 1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com Another Quality Building Product IIR_A50R_1016 Information contained within this document supersedes all previous versions and is subject to change without notice. Installation Resilmount A50R-1,2,3 Resilient Isolation Hanger PRODUCT CODE: A50R-1/2/3 PUBLICATION DATE: October 2016 1/2 INSTALLATION NOTES 1. Calculate the total weight of the ceiling per 16 sf. Estimated Weights of drywall per square foot.: 5/8” Drywall: 2.2 lbs. per sf ½ Drywall: 1.6 lbs. per sf - Keep in mind as you calculate the weight of your ceiling, additional products like lights and insulation. 2. Determine Hanger type needed: A50R-1: 65 lbs. per hanger A50R-2: 120 lbs. per hanger A50R-3: 200 lbs. per hanger 3. Fasten hanger to ceiling using a minimum 12 gauge wire. If a hanger bracket is needed we recommend using our M47 right angled bracket. 4. 1 Layer of 5/8” drywall - Space the A50R hanger a maximum 48”x48” OC. • 2 Layers of 5/8” drywall - Space the A50R hanger a maximum 48”x24” OC. • Space the hangers on the perimeters of the ceiling 6” away from the wall. IMPORTANT NOTES: - With a hung drywall ceiling leave a 1/8” - 1/4” gap around the perimeter of the drywall. - Fill all gaps with acoustical caulk in order to achieve the best noise results. Code Clip Height Max Deflection* Weight Capacity (lbs)* Color A50R-1 4” 3/16” 65 Red A50R-2 4” 3/16” 120 Black A50R-3 4” 3/16” 200 Blue SPECIFICATIONS *Maximum Deflection at Maximum weight # Lead time and minimum quantities may apply. Installation Instructions A50R-2 A50R-1 M47

Transcript of PRODUCT CODE: A50R-1/2/3 PUBLICATION DATE: October 2016 ... · IMPORTANT NOTES: - With a hung...

Page 1: PRODUCT CODE: A50R-1/2/3 PUBLICATION DATE: October 2016 ... · IMPORTANT NOTES: - With a hung drywall ceiling leave a 1/8” - 1/4” gap around the perimeter of the drywall. - Fill

A50R-3

For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023

1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com

Another Quality Building Product

IIR_A

50R

_101

6

Information contained within this document supersedes all previous versions and is subject to change without notice.

Inst

alla

tion

Resilmount A50R-1,2,3Resilient Isolation Hanger

PRODUCT CODE: A50R-1/2/3PUBLICATION DATE: October 2016

1/2

INSTALLATION NOTES

1. Calculate the total weight of the ceiling per 16 sf.Estimated Weights of drywall per square foot.:

5/8” Drywall: 2.2 lbs. per sf

½ Drywall: 1.6 lbs. per sf

- Keep in mind as you calculate the weight of your ceiling, additional products like lights and insulation.

2. Determine Hanger type needed:A50R-1: 65 lbs. per hanger

A50R-2: 120 lbs. per hanger

A50R-3: 200 lbs. per hanger

3. Fasten hanger to ceiling using a minimum 12 gauge wire. If a hanger bracket is needed we recommend using our M47 right angled bracket.

4. • 1 Layer of 5/8” drywall - Space the A50R hanger a maximum 48”x48” OC.

• 2 Layers of 5/8” drywall - Space the A50R hanger a maximum 48”x24” OC.

• Space the hangers on the perimeters of the ceiling 6” away from the wall.

IMPORTANT NOTES:

- With a hung drywall ceiling leave a 1/8” - 1/4” gap around the perimeter of the drywall.

- Fill all gaps with acoustical caulk in order to achieve the best noise results.

Code ClipHeight MaxDeflection* WeightCapacity(lbs)* Color

A50R-1 4” 3/16” 65 Red A50R-2 4” 3/16” 120 Black A50R-3 4” 3/16” 200 Blue

SPECIFICATIONS

*Maximum Deflection at Maximum weight

# Lead time and minimum quantities may apply.

Installation Instructions

A50R-2A50R-1

M47

Page 2: PRODUCT CODE: A50R-1/2/3 PUBLICATION DATE: October 2016 ... · IMPORTANT NOTES: - With a hung drywall ceiling leave a 1/8” - 1/4” gap around the perimeter of the drywall. - Fill

PRODUCT CODE: A50R-1/2/3PUBLICATION DATE: October 2016

A50R - Installation Instructions cont.

For Technical Support and Sales Enquiries, please contact Studco Building Systems 800.675.8023

1700 BOULTER INDUSTRIAL PARKWAY WEBSTER NY 14580 | PH: 800.675.8023 | [email protected] | www.resilmount.com

IIR_A

50R

_101

6

2/2

INSTALLATION LAYOUT

A50R CLIPS AT 24" x 48"

6" 24"

48"

6"24

"

48"

CR CLIPS AT 16" x 48" OC

CR CLIPS AT 24" x 48" OC

6"16

"

48"

6"24

"

48"

A237R / MBF / MBFS CLIPS AT 24" x 48"

OC

24"

6"24

"

48"

A237R / MBF / MBFS CLIPS AT 16" x 48"

OC

16

A50R Clips at 24” x 48” OC