Product Catalogue - Netberry€¦ · CINERGIA supplies high-technology products based on an...
Transcript of Product Catalogue - Netberry€¦ · CINERGIA supplies high-technology products based on an...
2016Product Catalogue
v 1.0
Who we areCINERGIA is the result of more than ten years of experience in the conception, design, manufacture and commissioning of customized power electronics solutions. Our core competencies are the development of power electronics converters, DSP-based digital control, industrial communica-tions and process automation. Our know-how is the result of continuous R+D in the �elds of electrical conversion, electromobility, renewable resources and smart grids.
Our productsCINERGIA supplies high-technology products based on an industrial hardware platform designed to work 24/7. By using di�erent DSP �rmware, developed by CINERGIA, our standard product portfolio includes DC, AC and DC&AC power sink/sources.
RegenerativeThanks to its bidirectional topology all our products can regenerate the test energy back to the grid, reducing the energy consumption and optimizing the electrical installation.
Our valueWe provide cutting edge technology at cost-competitive prices thanks to the combination of a robust industrial platform with CINERGIA’s proprietary control system.
We can adapt our solutions to your speci�c needs and provide the engineering support to achieve the desired result thanks to the knowledge and experience of our engineering team.
CINERGIA develops and supplies AC and DC Regenerative Power Converters for Industrial, R&D and Academic applications
DC platform
AC platform
GridEmulator
AC programmable
sourceCustomer
equipmentElectronic load(regenerative)
Grid AC/AC DC DeviceUnder test AC/AC
GridEmulator
DC programmable
sourceCustomer
equipmentElectronic load(regenerative)
Grid AC/DC DC DeviceUnder test DC/AC
ELECTROMOBILITYElectromomobility needs expertise in energy storage, batteries, battery charging, traction conver-ters, power supplies, communications and its control. CINERGIA supplies power electronics equipments and platforms for test in production lines, prototype validation, burn-in and R&D.
SMART GRIDSIEC de�nes the smart grid as an electricity network that intelligently integrate the actions of all its users- generators, consumers and those that do both. It is related with electrical vehicles, energy storage systems (ESS), renewable generation (DER), consumers , grid.tied/islanded systems, communication and energy manage-ment. CINERGIA can provide complete test solutions for Smartgrid Labs and Original Equip-ment Manufacturers.
SOLUTIONS
ACADEMIC AND R&DCINERGIA is your partner in Academic and R&D applications by adapting our standard products to the speci�c coming from academic and research requirements.
TEST PLATFORMSCINERGIA o�ers power electronics equipments, marked in green colour in the diagrams, as well as complete turn key solutions, for your testing needs: at the laboratory, production line, prototype and pre-series validation, burn-in, quality and R&D.
GridEmulator
BatteryCharger
AC/DCGridBms
+Batteries
BatteryEmulator
TractionConverter
VscInverter
Motor Generator
TestBench
AC/AC
ElectronicLoad
GridEmulator
BatteryEmulator Batteries
WindTurbine
Emulator
Grid
ElectricalVehicle
ElectricalVehicle
ElectronicLoad
MicrogridManager
BatteryCharger
(B2C)
BatteryCharger
PvEmulator u. DER e.
AcLoad
AC/AC DC/AC
SELECTION GUIDE
Constant Voltage
Constant Current
Constant Power
Constant Resistance
Battery Charge
Battery Emulation
PAGE
√
√
√
13
√
√
√
√
18
√
√
√
√
√
23
√
√
28
AC Grid Emulat
or
GE-AC
Voltage Source
Current Source
Harmonics
Grid disturbances
10 to 400Hz
360 to 800Hz
PAGE
√
√
√
√
1
√
√
√
7
√
√
√
†
√
√
√
√
33
√
√
√
37† Contact us for further information
AC Electronic L
oad
EL-AC High Frequency
AC Electronic L
oad (E
L-AC)
AC&DC Voltage Source
GE-AC&DC
AC&DC Current S
ource
EL-AC&DC
DC Power Supply
DCPS DC Electronic L
oad
EL-DC Bidire
ctional B
attery
Charger
B2C Battery
Emulator
BE AC&DC Voltage Source
GE-AC&DC
AC&DC Current S
ource
EL-AC&DC
√
√
√
33
√
√
√
√
37
CINERGIA’s Grid Emulators are AC programmable voltage sources specially designed to create AC grids and emulate its disturbances. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.
FUNCTIONAL DESCRIPTION
Generation of AC grid systems:-Three-phase system (3F+N) up to 480Vrms line-line-Single-phase system (F+N) up to 277Vrms line-neutral-Programmable frequency from 10 to 400Hz-Programmable phase angle-Programmable internal resistance
Generation of grid disturbances:-Voltage harmonics up to 780Hz (except 8,10, 12 and 14th) -Flicker -Over and Undervoltage-Interruptions-Voltage dips symetric and unsymetric (types A, B, C, D).-Frequency �uctuations.-Automatic test �les (*.csv)
All disturbances can be con�gured in amplitude, duration and repetition time.
Applications:Test of UPS, Photovoltaic and Eolic Inverters, EV Quick Battery Chargers, Vehicle to Grid (V2G), Energy Storage Systems (ESS) and other AC devices.
KEY FEATURES
7.5 kVA – 200 kVA
4 Quadrant Power Supply
Regenerative up to 100% rated power
AC Output: 25 to 277 Vrms, phase-neutral43 to 480 Vrms, phase-phaseup to 230Arms per phase10-400Hz Independent con�guration per phase:- Voltage magnitude - Phase angle- Harmonics (up to 780Hz)
Disturbance generation:Interruptions and voltage dips, Flicker, Over and Undervoltage, Frequency Fluctuation
AC&DC version available
GE-AC Grid Emulator
GEA
C_2
016_
v1
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
1
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM OF GE
AC Input is connected to the grid (neutral wire or DYn isolation transformer is required)
AC Output is connected to the Equipment Under Test (EUT) and can be used as:- Three-phase AC system- Three independent Single-phase AC systems (same frequency)- One parallelized Single-phase AC system (3 times rated current per phase)
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and an output side AC Inverter generating three independent AC voltages with programmable amplitude, phase angle and harmo-nic content by using a digital resonant control algorithm.
Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.
www.cinergia.coop
AC
Grid Emulator
GRID
DC AC
DC EQUIPMENT UNDER TEST
(EUT)
Optional
-U -U
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 P + NAC IN (GRID side) AC OUT (EUT side)
GE-AC Grid Emulator
GEA
C_2
016_
v1
2
FUNCTIONALITIES
www.cinergia.coop
Undervoltage Voltage interruptions Balanced voltage dips
Frequency �uctuation400Hz Aeronautics Grid
Voltage Harmonics
Transient time 2-5ms
Independent phase harmonics Unbalanced voltage dips
Flicker
Balanced voltage dips
GE-AC Grid Emulator
GEA
C_2
016_
v1
3
USER INTERFACE
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
Windows 7/10 user interface for remote operation and data acquisition.
Con�guration of harmonics Con�guration of disturbances
SOFTWARE FEATURES
GE-AC Grid Emulator
GEA
C_2
016_
v1
OptionsGalvanic IsolationIsolation monitorHigh Voltage (up to 295Vrms, p-n)Analog Input/Output PortRS485, RS232, CANLabview drivers
4
www.cinergia.coop
RANGE AND SPECIFICATIONSMAGNITUDE VALUE
Power 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 sOutput side (EUT side) AC Voltage Phase-neutral 25-277Vrms (10-100Hz) 25-210Vrms (101-200Hz) 25-150Vrms (201-400Hz) Rated AC Current1 Depends on model (see table) 10-230Arms Frequency Fundamental voltage 10-400Hz (0.1Hz resolution) Harmonics Per phase 1st - 15th at 50Hz (except 8,10,12 & 14) 1st - 13th at 60Hz (except 8,10&12) 1st above 100Hz Harmonic content Maximum % 1st: 100% 2nd-11th: 50%, 13th-15th:10% Modes of operation Constant Voltage Range2 Resolution3 Ripple3 9-100% <0.1% <1% Disturbance Generation Voltage dip and interruptions Over and Undervoltage Frequency variation Flicker Harmonic sequenceGeneral Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Rated AC Current depends on model (see table) and defines the maximum permanent current allowed. Minimum current is 0A. 2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information.All speci�cations are subject to change without notice.
GE-AC Grid Emulator
GEA
C_2
016_
v1
5
www.cinergia.coop
GE MODELS
GALVANIC ISOLATION (optional)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
RECOMMENDED CIRCUIT BREAKER
145145145145174217280381435458514612753
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
All speci�cations are subject to change without notice.
All speci�cations are subject to change without notice.
GE-AC Grid Emulator
GEA
C_2
016_
v1
GE7.5-ACGE10-ACGE15-ACGE20-ACGE30-ACGE40-ACGE50-ACGE60-ACGE80-ACGE100-ACGE120-ACGE160-ACGE200-AC
REFERENCE
7.51015203040506080100120160200
RATEDkVA kW
6.75913.518273645547290108128160
RATED CURRENTAC rms / phase AC rms/ global Independent mode Parallel mode10A15A20A25A40A50A65A80A105A130A155A185A230A
30A45A60A75A120A150A195A240A315A390A465A555A690A
WEIGHTkg
770x450x1100
880x590x1320
850x900x2000
DIMENSIONSDxWxH (mm)
150150150150150185185185265290290540550
6
AC Electronic Loads are power electronics devices that behave as an AC electrical load. While most electronic loads are dissipative, CINERGIA o�ers a comprehensive range of DC, AC and AC&DC full 4Q and full regenerative electronic loads.
FUNCTIONAL DESCRIPTION
Operation modes:-Constant Current (CC) -Constant Impedance (CI)-Constant Power (CP) -Automatic test from csv �le
Applications:R&D, production and reliability tests for applications requiring linear and non-linear AC loads. Test of AC voltage sources, UPS, AC generators and electrical devices (as fuses, circuit breakers and connectors).
In Smartgrid applications it can be used to emulate domestic appliances, a house, a building as well as grid-coupled generators: PV and eolic plants, Energy Storage Systems, Electrical Vehicles, V2G-Vehicle to Grid and other AC distributed generators.
80% typical energy and power saving:
KEY FEATURES
7.5 kVA – 200 kVA
4 Quadrant Power Supply
Regenerative up to 100% rated power
Full 4Q: pure capacitive and inductive current
AC Output: up to 230Arms per phase25 to 277 Vrms, phase-neutral10-400Hz
Independent con�guration per channel:- Fundamental current up to 400Hz- Harmonics up to 780Hz- Phase angle (-1 < cos � < 1) - Non-linear currents- Crest factor <3- Active / Reactive Power
AC&DC version available
EL-AC Electronic Load
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
GRIDEquipment Under Test
(EUT) 92 kW
8 kW100 kW11 1 .1kW
η=90%11.1 kW
19.1kW AC
Electronic Load
DC AC
DC η = 92%
92 kW
ELAC
_201
6_v1
7
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM OF EL-AC
AC Input is connected to the grid (neutral wire or DYn isolation transformer is required)
AC Output is connected to the Equipment Under Test (EUT) and can be used as:- Three-phase AC Wye load (balanced or unbalanced)- Three independent Single-phase AC systems (di�erent voltage/frequency is possible)- One parallelized Single-phase AC system (3 times rated current per phase)
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and an output side AC Inverter generating three independent AC currents with programmable amplitude, phase angle and harmo-nic content by using a digital resonant control algorithm.
Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.
www.cinergia.coop
AC
Electronic Load
GRID
DC AC
DC EQUIPMENT UNDER TEST
(EUT)
Optional
-
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
AC IN (GRID side)3 P + N
AC OUT (EUT side)3 P + N
-
EL-AC Electronic Load
ELAC
_201
6_v1
8
FUNCTIONALITIES
www.cinergia.coop
Resistive load Pure capacitive load Pure inductive load
Phase delay + harmonicsPhase delay
Single-phase recti�er
In previous oscilloscope captures: AC source under test (yellow), EL currents phase A, B and C (green, magenta, blue)
Three-phase recti�erHarmonics
Independent phase control
EL-AC Electronic Load
ELAC
_201
6_v1
9
USER INTERFACE
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
Windows 7/10 user interface for remote operation and data acquisition.
Con�guration of harmonics Con�guration of disturbances
SOFTWARE FEATURES
EL-AC Electronic Load
ELAC
_201
6_v1
OptionsGalvanic IsolationIsolation monitorLow Current RippleHigh Voltage (up to 295Vrms, p-n)Analog Input/Output PortRS485, RS232, CANLabview drivers
10
www.cinergia.coop
RANGE AND SPECIFICATIONSMAGNITUDE VALUE
Power 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 sOutput side (EUT side) AC Voltage Rated maximum, ch-neutral 25-277Vrms (10-100Hz) 25-210Vrms (101-200Hz) 25-150Vrms (201-400Hz) Rated AC Current1 Independent mode 10-230Arms per channel Parallel mode 30-690Arms global Frequency Fundamental current 10-400Hz Power factor Con�gurable by user 0-1 (capacitive/inductive) Harmonic Con�gurable by user 1st - 15th at 50Hz (except 8,10,12 & 14) 1st - 13th at 60Hz (except 8,10&12) 1st at 400Hz Harmonic content Maximum % 1st-9th: 100% 11th: 50%, 13th-15th:10% Crest factor <3Modes of operation Range2 Resolution3 Ripple3 Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Impedance (R,L,C) min.-100% <±0.1% <1%General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage (Vrms) and Current (Irms) Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Rated AC Current depends on model (see table) and defines the maximum permanent current allowed. Minimum current is 0A. 2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information.All speci�cations are subject to change without notice.
EL-AC Electronic Load
ELAC
_201
6_v1
11
www.cinergia.coop
EL-AC MODELS
EL7.5-ACEL10-ACEL15-ACEL20-ACEL30-ACEL40-ACEL50-ACEL60-ACEL80-ACEL100-ACEL120-ACEL160-ACEL200-AC
REFERENCE
7.51015203040506080100120160200
RATEDkVA kW
6.75913.518273645547290108128160
RATED CURRENTAC rms / phase AC rms/ global Independent mode Parallel mode10A15A20A25A40A50A65A80A105A130A155A185A230A
30A45A60A75A120A150A195A240A315A390A465A555A690A
WEIGHTkg
770x450x1100
880x590x1320
850x900x2000
DIMENSIONSDxWxH (mm)
GALVANIC ISOLATION (optional)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
RECOMMENDED CIRCUIT BREAKER
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
All speci�cations are subject to change without notice.
All speci�cations are subject to change without notice.
EL-AC Electronic Load
ELAC
_201
6_v1
150150150150150185185185265290290540550
145145145145174217280381435458514612753
12
CINERGIA’s DC converters are power electronics devices designed to generate a DC constant voltage, current, power, resistance or IU battery charge pro�le. Our DC products (DCPS, EL-DC, B2C) di�er in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.
FUNCTIONAL DESCRIPTION
Operation modes:-Constant Voltage (CV)-Constant Current (CC)-Constant Power (CP)-Automatic test from csv �le
Three DC channels in each unit:The three channels can be controlled independently allowing di�erent voltage, current or power setpoints.
In standard units the Operation mode will be the same for the three channels. Optionally, each channel could be operated in di�erent mode (if interested, please ask for option Independent Channels Operation).
2Q or 4Q applications:-In 2Q applications, the EUT will be connected between one channel and the common negative. -In 4Q applications, the EUT will be connected between two channels
KEY FEATURES
6.75 – 160 kW
2/4 Quadrant Power Supply
Regenerative up to 100% rated power
1 channel Output: 20 to 750V, 0 to ±555A
3 channels Output:20 to 750V, 0 to ±185A/ch
Bipolar Output-350 to +350V, 0 to ±185A
+270V/0/-270V Outputfor Avionics applications
CV, CC, CP modes
Option for Independent Channels Operation
DCPS Programmable DC Power Supply
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
DC
PS_2
016_
v1
13
CONCEPTUAL SCHEMATIC
DCPS Programmable DC Power Supply
TECHNICAL DIAGRAM
AC Input is connected to the grid (isolation transformer with neutral is recommended)
DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels)- One +270/0/-270V channels for avionics applications
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC converters generating three independent DC channels.
Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.
www.cinergia.coop
AC
DC Power Supply
GRID
DC DC
DC EQUIPMENT UNDER TEST
(EUT)
Recommended
-U -U
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 CH-COM
CH1CH2CH3Com_neg
AC IN (GRID side) DC OUT (EUT side)
DC
PS_2
016_
v1
14
0.0
100.0
200.0
300.0
400.0
500.0
600.0
700.0
800.0
Out
put v
olta
ge (V
)
Output current (A)
USER INTERFACE
DCPS Programmable DC Power Supply
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
Windows 7/10 user interface for remote operation and data acquisition.
SOFTWARE FEATURES
OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR
DC
PS_2
016_
v1
OptionsGalvanic Isolation (recommended)Isolation monitorIndependent Channels OperationAnalog Input/Output PortRS485, RS232, CANLabview drivers
Minimum output voltage
Minimum voltageat rated power
Parallel channelsmode
Independent channels mode
In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible con�gurations:
Independent channels: CH1, CH2 and CH3 are available and can be parametrized with di�erent voltage, current or power setpoint.
Parallelized channels: the three channels are “shortcircuited” internally to provide three times the current.
In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3.
This connection will be used to create +270V/0/-270V avionics DC bus system.
Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed.
-400.0
-300.0
-200.0
-100.0
0.0
100.0
200.0
300.0
400.0
Out
put v
olta
ge (V
)
Output current (A)
-Bipolar +Bipolar
15
DCPS Programmable DC Power Supply
www.cinergia.coop
RANGE AND SPECIFICATIONSMAGNITUDE VALUE
Power (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s
Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel DC Overcurrent 110% during 1 minOperation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information.All speci�cations are subject to change without notice.
DC
PS_2
016_
v1
16
DCPS Programmable DC Power Supply
www.cinergia.coop
MODELS
DCPS7.5DCPS10DCPS15DCPS20DCPS30DCPS40DCPS50DCPS60DCPS80DCPS100DCPS120DCPS160DCPS200
REFERENCE
7.51015203040506080100120160200
RATEDkVA kW
6.75913.518273645547290108128160
RATED CURRENT Independent Parallel Bipolar0-750v 0-750v -350 to 350V ±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A
150150150150150185185185265290290540550
WEIGHTkg
770x450x1100
880x590x1320
850x900x2000
DIMENSIONSDxWxH (mm)
GALVANIC ISOLATION (recommended)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
RECOMMENDED CIRCUIT BREAKER
145145145145174217280381435458514612753
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
All speci�cations are subject to change without notice.
All speci�cations are subject to change without notice.
DC
PS_2
016_
v1
17
CINERGIA’s DC converters are power electronics devices designed to generate a DC constant voltage, current, power, resistance or IU battery charge pro�le. Our DC products (DCPS, EL-DC, B2C) di�er in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.
FUNCTIONAL DESCRIPTION
Operation modes:-Constant Current (CC)-Constant Power (CP)-Constant Resistance (CR)
Three DC channels:-The three channels can be controlled independently, allowing di�erent setpoints on each channel-The three channels can be controlled in parallel, sharing the same setpoint and providing 3 times the current-In Unipolar 2Q applications, the sources will be connected between one channel and the common negative. -In Bipolar 4Q applications, the source will be connected between two channels
80% typical energy saving by regenerating to the grid:
KEY FEATURES
6.75 – 160 kW
2/4 Quadrant Power Supply
Regenerative up to 100% rated power
1 channel Output: 20 to 750V, 0 to ±555A
3 channels Output:20 to 750V, 0 to ±185A/ch
Bipolar Output-350 to +350V, 0 to ±185A
+270V/0/-270V Outputfor Avionics applications
CV, CC, CP, CV modes
Option for Independent Channels Operation
AC&DC version available
EL-DC DC Electronic Load
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
-Constant Voltage (CV)-Automatic test from csv �le
GRIDEquipment Under Test
(EUT) 92 kW
8 kW100 kW11 1 .1kW
η=90%11.1 kW
19.1kW DC
Electronic Load
DC AC
DC η = 92%
92 kW
ELD
C_2
016_
v1
18
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM
AC Input is connected to the grid (isolation transformer with neutral is recommended)
DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels)- One +270/0/-270V channels for avionics applications
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC converters generating three independent DC channels.
Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.
www.cinergia.coop
AC
DC Electronic Load
GRID
DC DC
DC EQUIPMENT UNDER TEST
(EUT)
Recommended
-U -U
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 CH-COM
CH1CH2CH3Com_neg
AC IN (GRID side) DC OUT (EUT side)
EL-DC DC Electronic Load
ELD
C_2
016_
v1
19
0.0
100.0
200.0
300.0
400.0
500.0
600.0
700.0
800.0
Out
put v
olta
ge (V
)
Output current (A)
USER INTERFACE
EL-DC DC Electronic Load
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
Windows 7/10 user interface for remote operation and data acquisition.
SOFTWARE FEATURES
OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR
ELD
C_2
016_
v1
OptionsGalvanic Isolation (recommended)Isolation monitorIndependent Channels OperationAnalog Input/Output PortRS485, RS232, CANLabview drivers
Minimum output voltage
Minimum voltageat rated power
Parallel channelsmode
Independent channels mode
In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible con�gurations:
Independent channels: CH1, CH2 and CH3 are available and can be parametrized with di�erent voltage, current or power setpoint.
Parallelized channels: the three channels are “shortcircuited” internally to provide three times the current.
In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3.
This connection will be used to create +270V/0/-270V avionics DC bus system.
Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed.
-400.0
-300.0
-200.0
-100.0
0.0
100.0
200.0
300.0
400.0
Out
put v
olta
ge (V
)
Output current (A)
-Bipolar +Bipolar
20
www.cinergia.coop
RANGE AND SPECIFICATIONSMAGNITUDE VALUE
Power (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s
Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel DC Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100%‡ <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Resistance Min.-100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information. All speci�cations are subject to change without notice.
EL-DC DC Electronic Load
ELD
C_2
016_
v1
21
www.cinergia.coop
MODELS
EL7.5-DCEL10-DCEL15-DCEL20-DCEL30-DCEL40-DCEL50-DCEL60-DCEL80-DCEL100-DCEL120-DCEL160-DCEL200-DC
REFERENCE
7.51015203040506080100120160200
RATEDkVA kW
6.75913.518273645547290108128160
RATED CURRENT Independent Parallel Bipolar0-750v 0-750v -350 to 350V
WEIGHTkg
DIMENSIONSDxWxH (mm)
GALVANIC ISOLATION (recommended)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE RECOMMENDED CIRCUIT BREAKER
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
EL-DC DC Electronic Load
All speci�cations are subject to change without notice.
All speci�cations are subject to change without notice.
ELD
C_2
016_
v1
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A
150150150150150185185185265290290540550
770x450x1100
880x590x1320
850x900x2000
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
145145145145174217280381435458514612753
22
CINERGIA’s DC converters are power electronics devices designed to generate a DC constant voltage, current, power, resistance or IU battery charge pro�le. Our DC products (DCPS, EL-DC, B2C) di�er in the possible operation modes. Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.
FUNCTIONAL DESCRIPTION
Operation modes:-Battery Charge (BC) -Constant Voltage (CV)-Constant Current (CC) -Constant Power (CP)-Constant Resistance (CR) -Automatic test from csv �le Three DC channels in each unit:The three channels can be controlled independently allowing di�erent voltage, current or power setpoints.
In standard units the Operation mode will be the same for the three channels. Optionally, each channel can be opera-ted in di�erent mode (option Independent Channels Operation).
2Q or 4Q applications:For testing bipolar current applications and bipolar voltage applications.
Battery charge is controlled with an IUoU algorithm. Battery discharge can be done at constant current, power or resistance. Battery cycling is possible by programming a sequence in a csv �le.
KEY FEATURES
6.75 – 160 kW
2/4 Quadrant Power Supply
Regenerative up to 100% rated power
1 channel Output: 20 to 750V, 0 to ±555A
3 channels Output:20 to 750V, 0 to ±185A/ch
Bipolar Output-350 to +350V, 0 to ±185A
+270V/0/-270V Outputfor Avionics applications
BC, CV, CC, CP, CR modes
IUoU and Equalization battery charge modes
Constant current or power battery discharge
B2C Bidirectional Battery Charger
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
B2C
_201
6_v2
23
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM
AC Input is connected to the grid (isolation transformer with neutral is recommended)
DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase) - One 4Q bipolar channel (connecting the load between two channels)- One +270/0/-270V channels for avionics applications
BACK-TO-BACK TOPOLOGY
The converter is formed by a grid-side Active Recti�er and an output DCDC converter sharing a DC-link. The Active Recti�er allows sinusoidal current consumption with low harmonic distortion and unity power factor. The DCDC converter generates three independent DC voltages controlling the voltage, current or power.
www.cinergia.coop
AC
B2C
GRID
DC DC
DC EQUIPMENT UNDER TEST
(EUT)
Recommended
-U -U
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 CH-COM
CH1CH2CH3Com_neg
AC IN (GRID side) DC OUT (EUT side)
B2C Bidirectional Battery Charger
B2C
_201
6_v2
24
www.cinergia.coop
B2C Bidirectional Battery Charger
B2C
_201
6_v2
0.0
100.0
200.0
300.0
400.0
500.0
600.0
700.0
800.0
Out
put v
olta
ge (V
)
Output current (A)
USER INTERFACE
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
Windows 7/10 user interface for remote operation and data acquisition.
SOFTWARE FEATURES
OPERATION AREA: UNIPOLAR OPERATION AREA: BIPOLAR
OptionsGalvanic Isolation (recommended)Isolation monitorIndependent Channels OperationAnalog Input/Output PortRS485, RS232, CANLabview drivers
Parallel channelsmode
Independent channels mode
In UNIPOLAR the equipment under test is connected between a channel and the common negative. Two possible con�gurations:
Independent channels: CH1, CH2 and CH3 are available and can be parametrized with di�erent voltage, current or power setpoint.
Parallelized channels: the three channels are “shortcircuited” internally to provide three times the current.
In BIPOLAR the equipment under test is connected between channels CH1, CH2 and CH3. The common negative is not connected and CH2 is used as 0V reference for CH1 and CH3.
This connection will be used to create +270V/0/-270V avionics DC bus system.
Maximum voltage in bipolar connection is ±350V. Ask for further information if ±750V are needed.
-400.0
-300.0
-200.0
-100.0
0.0
100.0
200.0
300.0
400.0
Out
put v
olta
ge (V
)
Output current (A)
-Bipolar
25
www.cinergia.coop
RANGE AND SPECIFICATIONSMAGNITUDE VALUE
Power (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s
Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Channel-Channel -350 to 350V Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel Bipolar output 0 to ±185A per channel DC Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 0-100% <±0.1% <1% Constant Current 0-±100% <±0.1% <1% Constant Power 0-±100% <±0.1% <1% Constant Resistance Min.-100% <±0.1% <1% Battery Charge 0-±100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-2
1 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information. All speci�cations are subject to change without notice.
B2C Bidirectional Battery Charger
B2C
_201
6_v2
26
www.cinergia.coop
MODELS
B2C7.5B2C10B2C15B2C20B2C30B2C40B2C50B2C60B2C80B2C100B2C120B2C160B2C200
GALVANIC ISOLATION (recommended)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE RECOMMENDED CIRCUIT BREAKER
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
B2C Bidirectional Battery Charger
All speci�cations are subject to change without notice.
7.51015203040506080100120160200
6.75913.518273645547290108128160
All speci�cations are subject to change without notice.
B2C
_201
6_v2
REFERENCE RATEDkVA kW
RATED CURRENT Independent Parallel Bipolar0-750v 0-750v -350 to 350V
WEIGHTkg
DIMENSIONSDxWxH (mm)
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A
150150150150150185185185265290290540550
770x450x1100
880x590x1320
850x900x2000
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
145145145145174217280381435458514612753
27
A Battery Emulator is a power electronics device that behaves as a real battery pack. CINERGIA’s BE is based on a regenerative power DC supply. When emulating a battery charge, the energy will be injected back to the electrical grid consuming a sinusoidal current with unity power factor and low harmonic distortion. Using a BE will save space in the laboratory, avoiding safety issues of real batteries and allow a high �exibility in the tests.
FUNCTIONAL DESCRIPTION
Operation modes:-Constant Voltage (CV)-Static-Dynamic
Three DC channels:The three channels can be con�gured independently, allowing emulation of di�erent batteries at the same time
The three channels can be con�gured in parallel, emulating one single battery with 3 times the rated current capabilityv
Static mode: the emulated battery voltage will depend on the open-circuit voltage and internal charge and discharge virtual resistance.
Dynamic mode: the emulated battery voltage will depend on the State Of Charge, rate of discharge and internal charge and discharge virtual resistance.
KEY FEATURES
6.75 – 160 kW
2 Quadrant Power Supply
Regenerative up to 100% rated power
1 channel Output: 0 to 750V, 0 to ±555A
3 channels Output:0 to 750V, 0 to ±185A/ch
Constant Voltage, Static, and Dynamic modes
BE Battery Emulator
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
BE Battery Emulator
BE_2
016_
v1
28
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM
AC Input is connected to the grid (isolation transformer with neutral is recommended)
DC Output is connected to the Equipment Under Test (EUT) and can be used as:- Independent channels mode: three 2Q channels with a common negative- Parallel channels mode: one 2Q channel (3 times rated current per phase)
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output DCDC converters generating three independent DC channels.
Thanks to the bidirectionality of this topology the test energy can be injected back to the grid.
www.cinergia.coop
AC
Battery Emulator
GRID
DC DC
DC EQUIPMENT UNDER TEST
(EUT)
Recommended
-U -U
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 CH-COM
CH1CH2CH3Com_neg
AC IN (GRID side) DC OUT (EUT side)
BE Battery Emulator
BE_2
016_
v1
29
USER INTERFACE
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
Windows 7/10 user interface for remote operation and data acquisition.
SOFTWARE INTERFACE
0.0
100.0
200.0
300.0
400.0
500.0
600.0
700.0
800.0
0 1ch mode3ch mode-3ch mode-1ch mode
Minimumvoltage atrated power
Out
put v
olta
ge (V
)
Output current (A)
OPERATION AREA: 1/3 CHANNELS
BE Battery Emulator
STATIC MODE
Voc
Rdisch
Rch
Vout
+
-
DYNAMIC MODE
CABINET
The battery is emulated through a simply�ed model based on �xed Voc and charge/discharge resistors.
A model based on battery manufacturer data allows realistic voltage and SOC behaviour.
BE_2
016_
v1
30
www.cinergia.coop
RANGE AND SPECIFICATIONSMAGNITUDE VALUE
ower (grid side) 7.5kVA-200kVAInput side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power ≥0.99 Con�gurable by user 0-1 (capacitive/inductive) E�ciency (at rated power) >92% Overload 125% for 10 min / 150% for 60 s
Output side (EUT side) DC Voltage Channel-Com_neg 20 to 750V (≤60kVA) Channel-Com_neg 40 to 750V (>60kVA) Minimum voltage at rated power1 320V DC Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±185A per channel DC Overcurrent 110% during 1 minOperation Modes Range2 Resolution3 Ripple3 Constant Voltage 5-100% <±0.1% <1% Static 5-±100% <±0.1% <1% Dynamic 5-±100% <±0.1% <1%Response time Rated resistance load 1-5ms (10-90%) General Measurements Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures User interface 3.2” Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP Humidity 10-90% (Absolute maximum, without condensation) Temperature 5-35 ºC (Absolute maximum) Cooling Forced air Protections Over Current, Over Voltage, Shortcircuit, OvertemperatureStandards CE Marking Safety EN-62040-1-2, EN-60950-1 EMC EMC: EN-62040-21 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail2 Range is related to rated values of each model as de�ned in table MODELS3 Resolution and ripple are related to the FS of each model. Contact us for further information. All speci�cations are subject to change without notice.
BE Battery Emulator
BE_2
016_
v1
31
www.cinergia.coop
MODELS
BE7.5BE10BE15BE20BE30BE40BE50BE60BE80BE100BE120BE160BE200
7.51015203040506080100120160200
6.75913.518273645547290108128160
GALVANIC ISOLATION (recommended)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE RECOMMENDED CIRCUIT BREAKER
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
BE Battery Emulator
OPTIONSGalvanic Isolation (recommended)Isolation monitorIsolated analog inputsRS485, RS232, CANLabview drivers
All speci�cations are subject to change without notice.
All speci�cations are subject to change without notice.
BE_2
016_
v1
REFERENCE RATEDkVA kW
RATED CURRENT Independent mode Parallel mode 0-750v 0-750v
WEIGHTkg
DIMENSIONSDxWxH (mm)
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A
150150150150150185185185265290290540550
770x450x1100
880x590x1320
850x900x2000
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
145145145145174217280381435458514612753
32
GE-AC&DC is the combination of two products in a single cabinet:a GE-AC and a DCPS. The equipment can be used alternatively in AC or in DC providing the highest �exibility at a very competitive price.Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid.
FUNCTIONAL DESCRIPTION
Two main modes:- AC mode: the three output channels work as AC Voltage Sources as a GE-AC- DC mode: the three output channels work as DC Voltage Sources (CV) or DC Current Sources (CC, CP) as a DCPS
Three output channels:- Independent control- Parallel control
AC mode: -Generation of AC 3-phase or 1-phase voltages-Con�gurable frequency from 10 to 400Hz-Con�gurable phase angle and internal resistance-Generation of disturbancesSee GE-AC datasheet for further information
DC mode:-Operation modes: CV, CC and CP-Automatic test from Excel �le-Unipolar 2Q or Bipolar 4Q applications See DCPS datasheet for further information
KEY FEATURES
7.5 –200kVA / 6.75-160kW
4 Quadrant Power Supply
Regenerative up to 100% rated power
AC Output: 25 to 277 Vrms, phase-neutral43 to 480 Vrms, phase-phaseup to 230Arms per phase10-400Hz
DC Output: 1 channel Output: 20 to 750V, 0 to ±555A
3 channels Output:20 to 750V, 0 to ±185A/ch
Bipolar Output-350 to +350V, 0 to ±185A
+270V/0/-270V Outputfor Avionics applications
GE-AC&DC AC&DC Voltage Source
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
GE_
ACD
C_v
_v1
33
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM
AC Input is connected to the grid (isolation transformer with neutral is recommended )AC Output is connected to the Equipment Under Test (EUT) and can be used as AC or DC output. The loads or EUT are connected between a phase and:- AC mode: the output neutral- DC mode: the common (COM) negative point for 2Q applications or to phase for 4Q applicationsThe AC or DC mode is selected by manual switch.
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and depending on the main mode, an output converter that can be con�gured either as an AC inverter or as a DCDC converter.
www.cinergia.coop
AC
Grid Emulator
GRID
DC AC or DC
DC EQUIPMENT UNDER TEST
(EUT)
Recommended
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 P + N + COM AC IN (GRID side) AC OUT (EUT side)
GE-AC&DC AC&DC Voltage Source
GE_
ACD
C_2
016_
v1
34
USER INTERFACE
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
OptionsGalvanic IsolationIsolation monitorBattery Charge mode (BC)IAnalog Input/Output PortRS485, RS232, CANLabview drivers
Windows 7/10 user interface for remote operation and data acquisition.
SOFTWARE FEATURES
Constant VoltageHarmonicsDisturbancesConstant Current Constant PowerConstant Resistance
√√√
√
√√√
AC mode DC mode
RANGE AND SPECIFICATIONSDetailed data can be found in datasheets of GE-AC and DCPS
GE-AC&DC AC&DC Voltage Source
GE_
ACD
C_2
016_
v1
35
www.cinergia.coop
GE-AC&DC MODELS
GE7.5-AC&DCGE10-AC&DCGE15-AC&DCGE20-AC&DCGE30-AC&DCGE40-AC&DCGE50-AC&DCGE60-AC&DCGE80-AC&DCGE100-AC&DCGE120-AC&DCGE160-AC&DCGE200-AC&DC
REFERENCE
7.51015203040506080100120160200
RATEDkVA kW
6.75913.518273645547290108128160
RATED CURRENTIndependent Mode Parallel modeArms/ch Adc/ch Arms Adc
WEIGHTkg
DIMENSIONSDxWxH (mm)
GALVANIC ISOLATION (recommended)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE RECOMMENDED CIRCUIT BREAKER
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23
All speci�cations are subject to change without notice.
All speci�cations are subject to change without notice.
GE-AC&DC AC&DC Voltage Source
GE_
ACD
C_2
016_
v1
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
145145145145174217280381435458514612753
10A15A20A25A40A50A65A80A105A130A155A185A230A
30A45A60A75A120A150A195A240A315A390A465A555A690A
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A
770x450x1100
880x590x1320
850x900x2000
150150150150150185185185265290290540550
36
EL-AC&DC is the combination of two products in a single cabinet: an EL-AC and an EL-DC. The equipment can be used alternatively in AC or in DC providing the highest �exibility at a very competitive price.Thanks to its bidirectional power hardware, the test energy can be regenerated to the electrical grid. FUNCTIONAL DESCRIPTION
Two main modes:- AC mode: the three output channels work as AC Current Sources (CC, CP, CI) as EL-AC- DC mode: the three output channels work as a DC Voltage Source (CV) or a DC Current Source (CC, CP, CR) as EL-DC
Three output channels:- Independent control- Parallel control
AC mode: -Consumption of AC 3-phase or 1-phase current-100% con�gurable power factor, inductive and capacitive -Con�gurable harmonics-Operation modes: CC, CP, CI-Automatic test from Excel �le
DC mode:-Operation modes: CV, CC, CP and CR-Automatic test from Excel �le-Unipolar 2Q or Bipolar 4Q applications
KEY FEATURES
7.5 –200kVA / 6.75-160kW
4 Quadrant Power Supply
Regenerative up to 100% rated power
AC Output: 1-phase Output: up to 690Arms3-phase Output:up to 230Arms per channel 1 channel Output: 20 to 750V, 0 to ±555A
3 channels Output:20 to 750V, 0 to ±185A/ch
Bipolar Output-350 to +350V, 0 to ±185A
+270V/0/-270V Outputfor Avionics applications
Allowed Voltage: 25 to 277Vrms,p-n in AC20 to 750V in DC
CINERGIAPintor Roig i Soler, 10 08916, Badalona, BARCELONAwww.cinergia.coop [email protected]. +34 934 864 358
EL-AC&DC AC&DC Electronic Load
VEL_
ACD
C_2
016_
v1
37
CONCEPTUAL SCHEMATIC
TECHNICAL DIAGRAM
AC Input is connected to the grid (isolation transformer with neutral is recommended )AC Output is connected to the Equipment Under Test (EUT) and can be used as AC or DC output. The loads or EUT are connected between a phase and:- AC mode: the output neutral- DC mode: the common (COM) negative point for 2Q applications or to phase for 4Q applicationsThe AC or DC mode is selected by manual switch.
BACK-TO-BACK TOPOLOGY
The equipment is formed by two IGBT-based power stages: a grid-side Active Recti�er producing sinusoidal currents with low harmonic distortion and close to unity power factor; and depending on the main mode, an output converter that can be con�gured either as an AC inverter or as a DCDC converter.
www.cinergia.coop
AC
Electronic Load
GRID
DC AC or DC
DC EQUIPMENT UNDER TEST
(EUT)
Recommended
EL-AC&DC AC&DC Electronic Load
EL_A
CD
C_2
016_
v1
EMC �lter
EMC �lter
DSP control
DSP control
Drivers x 6 Drivers x 6Current sensor x 3
Voltage sensor x 2
Voltage sensor x 3
Current sensor x 3
Voltage sensor x 3
HMI
CAN
MODBUS/TCPETHERNET
3 P + N 3 P + N + COM AC IN (GRID side) AC OUT (EUT side)
38
USER INTERFACE
www.cinergia.coop
Local 3.2” Touchscreen panel
Remote Control port: LAN Ethernet with Modbus/TCP protocol.
Digital IO port: -4 digital inputs-3 relay outputs-1 Emergency stop
Optional analog port:-1 analog input 0-10V-3 analog outputs 0-10V
Optional communications: RS485, RS232, CAN, LabView
CoolingThe power supply is air-cooled internally.
Mechanical housingThe power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation.
OptionsGalvanic Isolation (recommended)Isolation monitorAnalog Input/Output PortRS485, RS232, CANLabview drivers
Windows 7/10 user interface for remote operation and data acquisition.
SOFTWARE FEATURES
Constant CurrentHarmonicsConstant VoltageConstant PowerConstant ImpedanceConstant Resistance
√√
√√√
√
√√
√
AC mode DC mode
RANGE AND SPECIFICATIONSDetailed data can be found in datasheets of EL-AC and EL-DC
EL-AC&DC AC&DC Electronic Load
EL_A
CD
C_2
016_
v1
39
www.cinergia.coop
GALVANIC ISOLATION (optional)
IT7.5IT10IT15IT20IT30IT40IT50IT60IT80IT100IT120IT160IT200
REFERENCE RECOMMENDED CIRCUIT BREAKER
WEIGHTkg
Inside the cabinet
595x415x708 (*)
789x490x865 (*)
964x684x1252 (*)
1192x744x1430 (*)
DIMENSIONSDxWxH (mm)
(*) The transformer is delivered in a stand-alone cabinet IP23All speci�cations are subject to change without notice.
EL-AC&DC AC&DC Electronic Load
EL_A
CD
C_2
016_
v1
EL-AC&DC MODELS
EL7.5-AC&DCEL10-AC&DCEL15-AC&DCEL20-AC&DCEL30-AC&DCEL40-AC&DCEL50-AC&DCEL60-AC&DCEL80-AC&DCEL100-AC&DCEL120-AC&DCEL160-AC&DCEL200-AC&DC
REFERENCE
7.51015203040506080100120160200
RATEDkVA kW
6.75913.518273645547290108128160
RATED CURRENTIndependent Mode Parallel modeArms/ch Adc/ch Arms Adc
WEIGHTkg
DIMENSIONSDxWxH (mm)
All speci�cations are subject to change without notice.
10A15A20A25A40A50A65A80A105A130A155A185A230A
30A45A60A75A120A150A195A240A315A390A465A555A690A
±10A±15A±20A±25A±30A±38A±47A±57A±105A±130A±130A±155A±185A
±30A±45A±60A±75A±90A±115A±140A±180A±315A±390A±390A±465A±555A
770x450x1100
880x590x1320
850x900x2000
150150150150150185185185265290290540550
Type C - 25AType C - 25AType C - 32AType C - 40AType D - 80AType D - 100AType D - 125AType D - 160AType D - 200AType D - 250AType D - 315AType D - 400AType D - 500A
145145145145174217280381435458514612753
40
NOTES
41
CONTROL INTEL.LIGENT DE L’ENERGIA, SCCLPintor Roig i Soler 1008916 BadalonaBarcelonaSPAIN
T. +34 934 864 [email protected]