PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for...

60
Industrial Workplace | Hazardous Workplace | Fire Rescue | Marine | Military Manufacturers of RAMFAN Portable Ventilators PORTABLE VENTILATION FOR WORKING PROFESSIONALS

Transcript of PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for...

Page 1: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

Industr ial Workplace | Hazardous Workplace | Fire Rescue | Marine | Mil i tary

Manufacturers of RAMFAN Portable Ventilators

Portable Ventilation for working Professionals

2015PRODUCTCATALOG

Page 2: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

technical assistanceOur Customer Service Support and Engineers are available to assist you with any set-up, operation or application inquiries during our hours of operation. Operation manuals are also included in product packages. For assistance please contact Customer Service or email [email protected].

Placing Your orderContact our Customer Service Department if you need help with placing your order.

For prompt, accurate ordering please be able to provide the following:

n A Purchase Order or letter with the company name or logo, address & approval signature. Purchase Orders must include a P.O. #, Bill To Address, Ship To Address, Model #, Order #, quantity of each products ordered and shipping method.

Purchase Orders can be received by fax: +1 (619) 670-7345 or email: [email protected]

n A confirmation will follow all orders placed.

find us onwww.facebook.com/euramcosafety

sales and Customer service

aMeriCa

Hours of operation M–F 11:00 a.m. – 8:00 p.m. EST

Toll Free 1 (800) 472-6326Phone +1 (619) 670-9590Fax +1 (619) 670-7345

CHina

Hours of operation M–F 8:30 a.m. – 5:00 p.m.

Phone +86-574-87979390Fax +86-574-87979391

eUroPe – lUXeMboUrg

Hours of operation M–F 9:00 a.m. – 5:00 p.m.

Phone +352-26008055Fax +352-26008056

MiDDle east – DUbai (Jebel ali ftZ)

Hours of operation M–F 4:30 a.m. – 1:00 p.m.

Phone +1 (619) 670-9590 x114Fax +1 (619) 670-7345

Contents of this catalog are subject to change without notice.

Page 3: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

INDUSTRIAL 1WORKPLACEElectric

HAZARDOUS 11WORKPLACEElectric • Air

FIRE RESCUE 21Gas • Electric • Water

ACCESSORIES 47Ducting • Misting Systems • Plugs

America China Europe Middle East

TABLE OF CONTENTS

Page 4: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

Euramco Safety’s Certified Product Mark is our visual statement to you that RAMFAN Portable Ventilation Fans are Quality Manufactured and have been tested by Recognized Third Party Testing Facilities throughout the world to certify all product performance information quoted in our catalog, sales materials and on our website is accurate. In addition, the Certified Product Mark assures you that all required operating certifications and designations required by the applicable agencies are in order and available for your review.

euramco safety is an iso 9001:2008 Company: iso 9000 is the internationally recognized Quality Management Standard used in more than 760,000 companies in 154 countries to maintain an internationally accepted standardized quality management throughout the world. Our commitment to this standard means our products are built in accordance with documented procedures and control processes to ensure ongoing uniformity and reliability.

the air Movement and Control association | The Air Movement and Control Association is the worldwide recognized authority for the development of standards and measurement of air movement. Euramco Safety is a member of AMCA and uses their PPV test. ANSI/AMCA Standard 240 - Laboratory Methods of Testing Positive Pressure Ventilators for Aerodynamic Performance Rating establishes a uniform method of laboratory testing of positive pressure ventilators (PPVs) in order to determine the airflow rate.

ateX Hazardous Conditions Directive 94/9/eC | This directive applies to all electrical equipment for use in potentially explosive atmospheres; defined as gas, vapor or mist and are capable of causing an explosion through their own potential sources of ignition. RAMFAN Hazardous Location Fans are Whole Unit ATEX Certified for use in dangerous work environments as defined above anywhere in the world.

ieCex | The objective of the IECEx System is to facilitate international trade for equipment and services for use in explosive atmospheres, while maintaining the required level of safety. The IECEx has put in place a number of Confirmity Assessment Schemes which provide assurance that equipment and systems are manufactured and operated according to the highest International Standards of safety.

Underwriters laboratories, inc. | UL is an independent, third party product safety certification organization that evaluates products for compliance to specific standards and permits those products that comply to carry the UL Mark. The UL Mark is recognized worldwide as a symbol of product safety.

inMetro – national institute of Metrology, normalization and industrial Quality in brazil | Products obtain the INMETRO Certification Mark when they meet National Standards or specific technical requirements as detailed in the Brazilian Conformity Evaluation System (SBAC).

Uniform Conformity Procedures set forth by the european Union | The CE Mark is a mandatory marking for certain product groups and certifies that a product meets EU consumer safety, health or environmental requirements. In order to use the CE mark on a product the manufacturer must draw up a Declaration of Conformity in which they attest conformity with all relevant EU Directives.

Csa – Canadian standard association | CSA International is a recognized provider of product testing and certification services throughout the world. The CSA Mark signifies the product has been tested and meets applicable U.S. and Canadian Standards, including those from CSA and UL for safety and performance.

EURAMCO SAFETY’S CERTIFIEDPRODUCT MARK OF EXCELLENCE

Please note: You can find certification markings from the above organizations throughout the catalog. refer to page 53 for certification numbers and markings.

Page 5: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 1

INDUSTRIAL WORKPLACE

Page 6: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

2 www.euramcosafety.com

INDUSTRIAL WORKPLACE

Ub20 (12V DC)

raMfan combines high performance turbofan design with high strength polymers to create a line of rugged, portable turbo blowers. The UB-Line is ideal for general use, confined space, hazardous ventilation and delivers the highest airflow in their class. The double-wall, polyethylene casing is light-weight, corrosion and chemical resistant and handles the bumps and falls of any job site.

MODEL UB20 (60Hz) UB20 (50Hz) UB20 (12V)

order # eD7002 eD8002 eD9002

stoCk loCations

free air15ft/4.6m 1-90° turn 15ft/4.6m 2-90° turns

980cfm/1,666m3/hr 789cfm/1,341m3/hr 666cfm/1,132m3/hr

819cfm/1,392m3/hr 659cfm/1,120m3/hr 558cfm/948m3/hr

862cfm/1,465m3/hr 695cfm/1,181m3/hr 586cfm/996m3/hr

iMPeller 9-blade 9-blade 9-blade

DUCt aDaPter(s) 1 1 1

weigHt 17lbs/8kg 17lbs/8kg 17lbs/8kg

DiMensions (h/w/d)

14/12/13 in 355/305/330 mm

14/12/13 in 355/305/330 mm

14/12/13 in 355/305/330 mm

noise 74dB 74dB 74dB

Motor 0.33Hp/0.25kW 0.33Hp/0.25kW 0.25Hp/0.19kW

eleCtriC 115VAC, 1ø, 50/60Hz 240VAC, 1ø, 50/60Hz 12V DC

aMPs – rUn/start 2.5A/9.5A 1.3A/4.8A 11.5A

aPProVals

8”/20cm | UB20 Blower/Exhauster

n Powerful, compact size and lightweightn High pressure axial blower with ultra-quiet operationn Corrosion-proof, dent-resistant and virtually indestructiblen IP55 rain tested switch enclosuren Double-walled UV resistant

polyethylene housingn Thermal switch provides

overheat protectionn 15’/4.6m AC power cordn 15’/4.6m DC power cord

w/ battery clipsn IMPA Code: ED7002 - 591406n NSN Number: 4940-01-559-9190

Airflow Certified by Colorado Experimental Engineering Station, Inc. (CEESI)

See page 14 for hazardous location models

Page 7: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 3

Page 8: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

4 www.euramcosafety.com

INDUSTRIAL WORKPLACE

Ventilation System Applications

UB20 Turbo-Couple™ UB20 Battery-Pak

UB20 M.E.D.* UB20 Heating System EFi-Series Box Fans

* UB30 Compatible with Reducer Accessory.

Page 9: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 5

order # system includes

eD7015 8” 115V Blower/Exhauster, Quick-Couple™ Canister w/ 15’ duct

eD7025 8” 115V Blower/Exhauster, Quick-Couple™ Canister w/ 25’ duct

eD8015 20cm 240V, Blower/Exhauster, Quick-Couple™ Canister w/ 4.6m duct

eD8025 20cm 240V, Blower/Exhauster, Quick-Couple™ Canister w/ 7.6m duct

eD9015 8” 12V Blower/Exhauster, Battery Clips, Quick-Couple™ Canister w/ 15’ duct

eD9025 8” 12V Blower/Exhauster, Battery Clips, Quick-Couple™ Canister w/ 25’ duct

Quick-Couple™ Reversible CanisterDetachable in seconds, the Quick-Couple™ Canister with attached duct conveniently reverses from discharge to suction, making use and storage easier while protecting duct from rips and tears. Available with 15’/4.6m or 25’/7.6m of duct.

15’/4.6m blower w/ canister: 14h x 12w x 31.5d in. 35.6h x 30.5w x 80d cm

25’/7.6m blower w/ canister: 14h x 12w x 41.5d in. 35.6h x 30.5w x 105d cm

UB20 Turbo-Couple™ Long Distance Ventilation Solution

Quick-connecting two or more RAMFAN UB20 axial blowers in series increases airflow up to 50% when blowing through long, winding duct runs.

Designed for duct runs up to 25’/7.6m, the UB20 airflow significantly drops when blowing through more than 75’/22.9m of duct or when confronted with multiple turns in the duct.

Long, winding duct runs need more power and pressure to deliver sufficient airflow, a costly proposition. The Turbo-Couple™ delivers what is needed by quickly joining two or more UB20’s in series, each adding pressure and power to deliver a dramatic airflow increase through the duct.

Simple, cost effective and now available.

Pushes MORE air through long winding ducts Ventilate through 250ft/75m duct UB-line compatible High impact polyethylene housing

order # system includes

eD7300 Turbo-Couple™ Accessory

eD7000tC 8” 115V, 50/60Hz Blower/Exhausters (qty. 2) and Turbo-Couple™

eD8000tC 20cm 240V, 50/60Hz Blower/Exhausters (qty. 2) and Turbo-Couple™

Page 10: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

6 www.euramcosafety.com

INDUSTRIAL WORKPLACE

Battery Pak & Charger – 12V DC High-Low Control UB20RAMFAN’s long-life Battery Pak now with dual high-low speed control. Pulse width modulation extends battery life up to 8 hours in low setting yet gives a full 2.5 hours on high. UB20 fan can be powered by vehicle battery with supplied connector. Built-in charger allows you to fully recharge the battery cable in 12 hours.

Purge the area on high for 10 minutes, reduce to low speed (low-noise as well) and maintain fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers.

High-low control enables fast-purge ventilation and lower speed for maintaining safe work space

High impact case includes battery and built-in charger for overnight charging

Up to 10 hours of continuous operation Lightweight and portable

order # system includes

bPV-12/bPV-12Ce 12V DC Battery Pak w/ built in Charger

eD9015-bat/eD9015-batCe 8”/20cm Blower/Exhauster, 12V DC Battery Pak with Built-in Charger, Quick-Couple™ Canister with 15’/4.6m duct

eD9025-bat/eD9025-batCe 8”/20cm Blower/Exhauster, 12V DC Battery Pak with Built-in Charger, Quick-Couple™ Canister with 25’/7.6m duct

Page 11: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 7

UB20 M.E.D.™ Manhole Entry Device

The M.E.D.™ allows workers to enter and exit through small man-size openings while maintaining continuous ventilation. Without such a device, duct fills the manhole opening, preventing rapid entry and exit.

Tightly integrated into the UB-line of confined space ventilation equipment, RAMFAN’s M.E.D.™ is quick to assemble and the new swiveling elbow makes duct alignment easy.

Changing its cross-section from circular to elliptical and back to circular minimizes loss and optimizes airflow into a confined space, while providing adequate room for the worker to enter and exit unimpeded. The rugged polyethylene construction endures heavy wear and tear and will last for years.

Comprised of three components, the M.E.D.™, swiveling elbow, and universal mount, the RAMFAN M.E.D.™ system increases safety by maintaining continuous airflow.

Ventilate without blocking entry Maintain airflow while working UB-line compatible High impact polyethylene housing

See page 15 for anti-static M.E.D.™ System

System Includes (or may be individually ordered): 8”/20cm Blower/Exhauster, Quick-Couple™ Canister with 15’/4.6m and 5’/1.5m of duct, Manhole Entry Device, 90° Elbow, Universal Mount, 8”/20cm duct adapter for additional duct connections.

order #

eD7015-MeD M.E.D. System with 115V, 50/60Hz Blower

eD8015-MeD M.E.D. System with 240V, 50/60Hz Blower

eD9015-MeD M.E.D. System with 12V DC Blower

set-UP ProCeDUre1. Remove Manhole Lid2. Place Manhole Mount at the edge of the manhole so that the hook on the

mount is hanging a few inches over the manhole. Place the Manhole lid at the opposite end (lid will be propped up by manhole mount).

3. Attach the 15’/4.6m Duct to the bottom of the M.E.D.™4. Secure the M.E.D.™ by hooking onto Manhole Mount5. Attach the 90º Elbow by lining up the arrows at the bottom of the elbow with

the arrows at the top of the M.E.D.™ then twisting a half rotation.6. Set up Blower and Canister with 5’/1.5m Duct approx. 7’/2m away from

manhole. Attach Canister to blower using the rubber latches on the side of the Canister.

7. Pull out Duct from Canister and attach to the 90º Elbow8. Plug Blower into power source and turn on.

tYPiCal setUP

blower

Canister5’/1.5m

Duct90º elbow

Universal Mount

M.e.D.™

15’/4.6m Duct

Page 12: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

8 www.euramcosafety.com

INDUSTRIAL WORKPLACE

MODEL HA01

stoCk loCations

free airStraight Duct 1-90° turn 2-90° turns

947cfm 15ft: 520cfm 25ft: 521m3/hr 15ft: 485cfm 25ft: 432m3/hr 15ft: 467cfm 25ft: 414m3/hr

DUCt aDaPter(s) 1

Power 115VAC, 1ø, 60Hz

oUtPUt 55k BTU (gross)

weigHt 32lbs

DiMensions (h/w/d) 22/13/14 in

aPProVals

Airflow Certified by Colorado Experimental Engineering Station, Inc. (CEESI) *HA04 70k BTU optional

ORDER PACKAGES

Confined space Heating

order # Ha01-100Ht

system options UB20 8” Blower, Heater with Regulator, Quick-Couple™ Canister w/ 15’ Duct

order # Ha01-125Ht

system options UB20 8” Blower, Heater with Regulator, Quick-Couple™ Canister w/ 25’ Duct

tent/shelter Heating

order # eD7125-Ht

system options UB20 8” Blower, Heater with Regulator, 15’ Duct, Duct Storage Bag

UB20 In-Line Heating SystemRAMFAN’s UB20 In-Line Heating System with its propane-fired, heat-exchanger provides safe, warm breathing air during cold conditions.

For tent/shelter or confined space heating Airflow can cycle with heat or run continuous

for confined space ventilation Remote thermostat included Up to 10 hours of continuous operation with standard propane cylinder tank

Heater attaches quickly and easily to UB20 blower

Includes propane regulator and connection assembly

Easy access top mounted heater control panel Compatible with UB20 M.E.D.™ system 15’/4.6m power cord w/ IP55 rain tested

switch enclosure

Page 13: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 9

Patent nos. D583,461; D585,972; D588,537

MODEL UB30 UB30

order # eJ4002 eJ8002

stoCk loCations

free air

15ft/4.6m DuctStraight 1-90° turn 2-90° turns

25ft/7.6m DuctStraight 1-90° turn 2-90° turns

2,420cfm/4,114m3/hr

2,250cfm2,050cfm1,875cfm

1,950cfm 1,825cfm 1,750cfm

2,017cfm/3,429m3/hr

2,805m3/hr2,550m3/hr2,340m3/hr

2,465m3/hr 2,380m3/hr2,250m3/hr

iMPeller 11-blade 11-blade

DUCt aDaPter(s) 2 2

weigHt 37lbs/17kg 37lbs/17kg

DiMensions (h/w/d)

20/15.5/12 in 508/394/305 mm

20/15.5/12 in 508/394/305 mm

noise 95dB 95dB

Motor 1Hp 0.8kW

eleCtriC 115V, 1ø, 50/60Hz 240V, 1ø, 50/60Hz

aMPs – rUn/start 8A/33A 5A/17A

aPProVals

12”/30cm | UB30 High Volume Blower/Exhauster

Dual voltage/dual frequency/one unit High impact polyethylene shell Glass-filled nylon turbo fan blade Low starting amps IP55 rain tested switch enclosure Stackable design feature Comes with standard 15’/4.6m power cord Compatible with UB20 M.E.D™ System IMPA Codes:

EJ4002 - 591403 EJ8002 - 591407

Optional Accessories: Standard Duct, Duct Storage Bag, Duct Reducer/ Adapter

COMPETITIVE/PERFORMANCE

0

0.5

1.0

1.5

2.0

2.5

25’ 1–9

0

15’ 1–90

UB30 Performance IncreaseVAF-3000

UB30

VAF-3000

Pres

sure

in in

ches

of

H20

CFM 250 500 750 1000 1250 1500 1750 2000 2250 2500

m3/hr 425 850 1275 1700 2125 2550 2975 3400 3825 4250

AirflowUB30 60HzVAF-3000 60HzUB30 50HzDuct Resistance Curve-12”

Page 14: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

10 www.euramcosafety.com

MODEL EFi50 EFi120 (50Hz) EFi150

order # ea8000, ea8000-230 ea8120 eg8200, eg8200-230

stoCk loCations

free air

15ft/4.6m 1-90° turn

3,200cfm/5,440m3/hr

1,934cfm/3,289.5m3/hr

3,750cfm/6,375m3/hr

2,700cfm/4,590m3/hr

4,459cfm/7,580m3/hr

3,179cfm/5,404m3/hr

iMPeller 21-blade 7-blade 7-blade

DUCt aDaPter(s) 2 2 2

weigHt 46lbs/21kg 53lbs/24kg 55lbs/25kg

DiMensions (h/w/d)

19/18/16 in 483/457/407 mm

19/18/16 in 483/457/407 mm

19/18/16 in 483/457/407 mm

noise 90.2dB 86.1dB 90.2dB

Motor 0.5Hp/0.37kW 1.2Hp/0.9kW 1.5Hp/1.1kW

eleCtriC 115/230VAC, 1ø, 50/60Hz 110/240VAC, 1ø, 50Hz 115/230VAC, 1ø, 50/60Hz

aMPs – rUn/start 115V: 21A 230V: 10A 115V: 6A 230V: 3A

110V: 54A 240V: 27A 110V: 12A 240V: 5A

115V: 80A 240V: 40A 115V: 15A 230V: 8A

aPProVals – –

16”/40cm | EFi50/EFi120/EFi150 High Volume Blower/Exhauster

Engineered to move high volumes of air Stackable for additional easy storage High strength, glass reinforced ABS housing is lightweight,

corrosion-proof and chemical resistant IP55 rain tested switch enclosure New polymer TurboForce™ impeller for increased shatter

resistance and enhanced performance 15ft/4.6m power cord included IMPA Codes:

EA8000 (110V) - 591502 EA8000-230 (230V) - 591502

Optional Accessories: Standard Duct, Disposable Duct, Layflat Duct, Duct Carrying Bags, 16”/40cm Multi-purpose Accessory Pack

INDUSTRIAL WORKPLACE

efi120/150

Page 15: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 11

HAZARDOUS WORKPLACE

Page 16: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

12 www.euramcosafety.com

HAZARDOUS WORKPLACE

worldwide Certified explosion-Proof Ventilators

Euramco Safety has designed and manufactured a line of fans specifically for use in hazardous atmospheres to meet the standards specified by the ATEX Directive 94/9/EC, IECEx, CE, INMETRO and UL. Our certifications cover the whole unit: the motor, terminal box, power cable, fan blade and labeling.

These Standards apply to all electrical equipment to prevent or minimize potential source of ignition in hazardous gas, dust or vapor atmospheres, to the extent defined in the charts below.

The chart explains the ATEX Identification Numbering System. The highlighted areas specifically apply to the ATEX string seen on Euramco Safety’s certified hazardous location fans.

EQUIPMENT GROUP & CATEGORYEquipment Group

Equipment Category

Protection Level

HazardUseGas Dust

I - Mining M1 Very high protection – – Operable in

Ex atmosphereM2 High

protection – – De-energized in Ex atmosphere

II - Industrial (non-Mining)

1 Very high protection

G – Zones 0, 1, 2– D Zones 20, 21, 22

2 High protection

G – Zones 1, 2– D Zones 21, 22

3 Normal protection

G – Zone 2– D Zone 22

CLASSIFICATION OF HAZARDOUS AREASArea Classification Zone Criteria

Gases Dusts (based on frequency and duration)Zone 0 – Potentially Explosive substance present

continuously or for long periods > 1000hrs/yr– Zone 20Zone 1 – Potentially Explosive substance likely to be present

in normal operation > 10hrs > 1000hrs/yr– Zone 21Zone 2 – Potentially Explosive substance unlikely to be

present in normal operation, if it does will only be for short periods <10hrs/yr– Zone 22

ii 2 g ex de iib t6 gb

Equipment Group IIEquipment Category 2

Hazard G

Ignition Protection Category Ex de

Temperature Class T6

Gas Group IIB

IGNITION PROTECTION CATEGORIES

Ignition Protection Categories I.D. Can Be Used In Safety Principle

Increased safety Ex e Zone 1 No arcs, sparks or hot surfacesNon-sparking equipment Ex nA Zone 2

Pressurized encapsulation Ex d Zone 1 Controls an internal explosion and extinguishes the flameSand encapsulation Ex q Zone 1

Enclosed switching device Ex nC Zone 2Intrinsic safety (special requirements) Ex ia Zone 0 Limits the energy of the

sparks and the temp. of the surface

Intrinsic safety temperature Ex ib Zone 1Energy-limiting equipment Ex nL Zone 2Encapsulation Ex m Zone 1 Separates source of ignition

from potentially explosive atmosphere

Oil encapsulation Ex o Zone 1Pressurization Ex p Zone 1Simplified pressurization Ex nP Zone 2Vapor-proof housing Ex nR Zone 2

Junc

tio

nb

oxM

oto

r

Conditions & Subdivisions

Gb

at

eX

st

rin

g

Page 17: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 13

TEMPERATURE CLASSESClass T1 T2 T3 T4 T5 T6

MAXIMUM SURFACE TEMPERATURE

450ºC 300ºC 200ºC 135ºC 100ºC 85ºCIIA Acetone

Ammoniac Benzene Acetic Acid Ethane Ethyl Acetate Ethyl Chloride Methane Methanol Naphthalene Phenol Propane

i-Amylacetate n-Butane n-Butyl Alcohol

Gasolines Diesel Fuels Heating Oils n-Hexane

Acetyl-dehyde

– –

IIB Town gas (lighting gas)

Ethylene Ethylene Oxide

Hydrogen Sulfide

Ethylether – –

IIC Hydrogen Acetylene – – – Carbon

gas group iib, Class t6 includes all specifications for gas group iia, Class t1-t6 and gas group iib, t1-t6

GAS GROUPSGas Group Representative Test Gas

I Methane (Mining only)

IIA PropaneIIB EthyleneIIC Hydrogen

Gases are classified according to the ignitability of gas-air mixture. Refer to IEC 60079-20 for classification of common gases and vapors.

gas group iib includes all gases for group iia

Highlighted areas in charts apply to euramco safety’s ateX Certification string

CONDITIONS & SUBDIVISIONS

FlammableMaterials

Temporary Behaviorof Explosive Atmosphere

Classicationof HazardousAreas

Group as Defined in Directive 94/9/EC

Equipment Category as Defined in Directive 94/9/EC

EquipmentGroup as Defined in EN 60079-O

Equipment Protection Level (EPL) as Defined in EN 60079-O

Gases/ Vapors

is present continuously orfor long periods or frequently

Zone 0 II 1G II Ga

arises in normaloperation occasionally

Zone 1 II 2G or 1G II Gb or Ga

is not likely to arise in normal operation, or if it does, will persist for a short time only

Zone 2 II 3G or2G or 1G

II Gc orGb or Ga

Dusts is present in the form of acloud continuously, or forlong periods or frequently

Zone 20 II 1D III Da

occasionally develops into a cloud during normal operation

Zone 21 II 2D or 1D III Db or Da

is not likely to develop into a cloud during normal operation, or if it does, for a short time only

Zone 22 II 3D or2D or 1D

III Dc orDb or Da

Methane Carbon Dust

operation where there isa risk of explosion

– I M1 I Ma

disconnection where thereis a risk of explosion

– I M2 or M1 I Mb or Ma

Certifications:IECEx UL Certificate #: 13.0062XEC-Type Examination Certificate #: DeMko 09 ateX 0926969XINMETRO Certificate #: Ul-br 13.0593X CE Hazardous Location Marking: Ce0539 Ingress Protection: iP55

Page 18: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

14 www.euramcosafety.com

HAZARDOUS WORKPLACE ELECTRIC

MODEL UB20xx (60Hz) UB20xx (60Hz) with Q-C Canister*

UB20xx (50Hz) UUB20xx (50Hz) with Q-C Canister*

order # ef7002 ef7005 (w/ duct adapter)

ef7015 (15’/4.6m duct) ef7025 (25’/7.6m duct)

ef8002 ef8005 (w/ duct adapter)

ef8015 (15’/4.6m duct) ef8025 (25’/7.6m duct)

stoCk loCations

free air15ft/4.6m 1-90° turn 15ft/4.6m 2-90° turns25ft/7.6m 1-90° turn 25ft/7.6m 2-90° turns

980cfm/1,666m3/hr789cfm/1,341m3/hr 666cfm/1,132m3/hr 722cfm/1,227m3/hr 614cfm/1,044m3/hr

980cfm/1,666m3/hr789cfm/1,341m3/hr 666cfm/1,132m3/hr 722cfm/1,227m3/hr 614cfm/1,044m3/hr

819cfm/1,392m3/hr659cfm/1,120m3/hr 557cfm/947m3/hr 603cfm/1,025m3/hr 510cfm/867m3/hr

819cfm/1,392m3/hr659cfm/1,120m3/hr 557cfm/947m3/hr 603cfm/1,025m3/hr 510cfm/867m3/hr

DUCt aDaPter(s) 1 0 1 0

weigHt 22lbs/10kg 22lbs/10kg 22lbs/10kg 22lbs/10kg

DiMensions (h/w/d)

14/12/14 in 356/305/356 mm

14/12/14 in 356/305/356 mm

14/12/14 in 356/305/356 mm

14/12/14 in 356/305/356 mm

noise 74dB 74dB 74dB 74dB

Motor 0.33Hp/0.25kW 0.33Hp/0.25kW 0.33Hp/0.25kW 0.33Hp/0.25kW

eleCtriC 115VAC, 1ø, 50/60Hz 115VAC, 1ø, 50/60Hz 220VAC, 1ø, 50Hz 220VAC, 1ø, 50Hz

aMPs – rUn 2A 2A 1.2A 1.2A

aPProVals

Part no. ef0304xDuct adapter

8”/20cm | UB20xx Hazardous Location Blower/Exhauster

Worldwide certified explosion-proof or safe use in a variety of adverse atmospheres

Compact and lightweight Tough dual wall casing – weather proof, chemical resistant and dent proof

IP55 rain tested switch enclosure Ultra-quiet operation Power cable is 30ft/9m long. See page 50 for plug options.

IMPA Codes: EF7002 - 591416 EF8002 - 591417

NSN Number: 4940-01-603-7098

Optional Accessories: Quick-Couple™ Canister, Duct Adapters, Anti-Static Duct, Duct Carrying Bags

Page 19: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 15

UB20xx M.E.D.™ Manhole Entry Device

The anti-static UB20xx system utilizes high strength polymers with an anti-static housing designed to discharge static build-up safely. The M.E.D.™ allows workers to enter and exit small man-size openings while maintaining continuous ventilation. Without such a device, duct fills the manhole opening, preventing rapid entry and exit.

Tightly integrated into the UB-line of confined space ventilation equipment, RAMFAN’s M.E.D.™ is quick to assemble and the new swiveling elbow makes duct alignment easy.

Changing its cross-section from circular to elliptical and back to circular minimizes loss and optimizes airflow into a confined space, while providing adequate room for the worker to enter and exit unimpeded. The rugged polyethylene construction endures heavy, negligent use and will last for years.

Comprised of three components, the M.E.D.™, swiveling elbow, and universal mount, the RAMFAN M.E.D.™ system increases safety by maintaining continuous airflow.

Ventilate without blocking entry Maintain airflow while working UB-line compatible Anti-Static housing

System Includes: 8”/20cm Blower/Exhauster, Quick-Couple™ Canister with 15’/4.6m and 5’/1.5m of duct, Manhole Entry Device, 90°

Elbow, Universal Mount, 8”/20cm duct adapter for additional duct connections.

Patents: U.S. #6,843,274, #7,467,645, #7,992,593 B2; Canadian #2,561,299, #2,436,809; China CN1813137b;

European #1491695; Australian 2004 202394

order #

ef7015-MeDXX 115V/60Hz Blower with 15’/4.6m and 5’/1.5m Duct

ef8015-MeDXX 220V/50Hz Blower with 15’/4.6m and 5’/1.5m Duct

set-UP ProCeDUre1. Remove Manhole Lid2. Place Manhole Mount at the edge of the manhole so that the hook on the

mount is hanging a few inches over the manhole. Place the Manhole lid at the opposite end (lid will be propped up by manhole mount).

3. Attach the 15’/4.6m Duct to the bottom of the M.E.D.™4. Secure the M.E.D.™ by hooking onto Manhole Mount5. Attach the 90º Elbow by lining up the arrows at the bottom of the elbow with

the arrows at the top of the M.E.D.™ then twisting a half rotation.6. Set up Blower and Canister with 5’/1.5m Duct approx. 7’/2m away from

manhole. Attach Canister to blower using the rubber latches on the side of the Canister.

7. Pull out Duct from Canister and attach to the 90º Elbow8. Plug Blower into power source and turn on.

tYPiCal setUP

blower

Canister5’/1.5m

Duct90º elbow

Universal Mount

M.e.D.™

15’/4.6m Duct

warning: for potentially explosive environments, follow ansi/aPi 2015 and 2016 procedures

ELECTRIC

Page 20: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

16 www.euramcosafety.com

HAZARDOUS WORKPLACE ELECTRIC

MODEL EFi75xx

order # eb7201XX/eb7201XX-230

stoCk loCations

free air15ft/4.6m 1-90° turn 15ft/4.6m 2-90° turns

2,500cfm/4,250m3/hr 1,664cfm/2,829m3/hr 1,529cfm/2,599m3/hr

iMPeller 17-blade

DUCt aDaPter(s) 2

weigHt 44lbs/20kg

DiMensions (h/w/d)

16/15/16 in 406/381/406 mm

noise 89dB

Motor 0.75Hp/0.56kW

eleCtriC 115/230VAC, 1ø, 50/60Hz

aMPs – start – rUn

115V: 37A 230V: 27A 115V: 7.2A 230V: 3A

aPProVals

12”/30cm | EFi75xx Dual Voltage, Dual Frequency Blower/Exhauster

ATEX certified for use in adverse atmosphere Tough, chemical resistant ABS housing, carbon-filled

to conduct static charges to ground IP55 rain tested switch enclosure “watertight” Blow or exhaust hazardous/explosive gases safely Power cable is 30ft/9m long.

See page 50 for plug options. IMPA Codes:

EB7201xx (115V) - 591506, 591418, 591423 EB7201xx-230 (230V) - 591506, 591419,591424

Optional Accessories: Anti-Static Duct, Duct Carrying Bags

Page 21: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 17

16”/40cm | EFi50xx/EFi120xx/EFi150xx Stackable Blower/Exhauster

Models EFi120xx and EFi150xx are whole-unit ATEX certified for safe use in adverse atmospheres

Blow/exhaust hazardous or explosive gases safely High strength, anti-static glass reinforced ABS housing is

lightweight, corrosion proof and chemical resistant IP55 rain tested switch enclosure Stackable for easy storage Power cable is 30ft/9m long.

See page 50 for plug options. IMPA Codes:

EG8200x (115V) - 591507 EG8200xx-230 (230V) - 591507

NSN Number: 4140-01-608-6001

Optional Accessories: Anti-Static Duct, Duct Carrying Bags

efi120/150xx

ELECTRIC

MODEL efi50xx EFi120xx (50Hz) EFi150xx

order # ea8000XX ea8120XX eg8200XX, eg8200XX-230

stoCk loCations

free air15’/4.6m 1-90° turn

3,200cfm/5,440m3/hr 1,935cfm/3,289m3/hr

3,750cfm/6,375m3/hr 2,700cfm/4,590m3/hr

4,459cfm/7,580m3/hr 3,179cfm/5,404m3/hr

iMPeller 21-blade 7-blade 7-blade

DUCt aDaPter(s) 2 2 2

weigHt 49lbs/22kg 55lbs/25kg 61lbs/28kg

DiMensions (h/w/d)

19/18/16 in 483/457/407 mm

19/18/16 in 483/457/407 mm

19/18/16 in 483/457/407 mm

noise 90.2dB 86.1dB 90.2dB

Motor 0.5Hp/0.37kW 1.2Hp/0.9kW 1.5Hp/1.1kW

eleCtriC 115/230VAC, 1ø, 50/60Hz 110/240V VAC, 1ø, 50Hz 115/230VAC, 1ø, 50/60Hz

aMPs – start – rUn

115V: 21A 230V: 10A 115V: 6A 230V: 3A

110V: 54A 240V: 27A 110V: 10A 240V: 5A

115V: 80A 230V: 40A 115V: 15A 230V: 8A

aPProVals

LR66789

Page 22: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

18 www.euramcosafety.com

HAZARDOUS WORKPLACE

MODEL AFi50xx

order # aa7000

stoCk loCations

free air* 3,200cfm/5,440m3/hr

iMPeller 21-blade

DUCt aDaPter(s) 2

air ConsUMPtion 40cfm/68m3/hr

inDUCtion ratio 80:1

weigHt 43lbs/20kg

DiMensions (h/w/d)

19/21/16 in 480/530/407 mm

noise 89dB

Motor GAST 4AM-NRV-50C

aPProVals

* Measurements @ 80psig inlet air

16”/40cm | AFi50xx Hazardous Location Air Driven Blower/Exhauster

Pneumatic powered blower is safe for use in adverse atmospheres

High strength, anti-static glass reinforced ABS housing is lightweight, corrosion proof and chemical resistant

Exhausts OUTSIDE of duct, compressed air not in airstream

Complete with filter, motor lubricator, exhaust muffler, air control valve and static grounding cord

Stackable for easy storage IMPA Codes: AA7000 - 591512, 591426

Optional Accessories: Standard Duct, Anti-Static Duct, Duct Carrying Bags, Cooling Collar,

AIR

Page 23: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 19

12”/30cm | AFi75xx Hazardous Location Air Driven Blower/Exhauster

Pneumatic powered blower is safe for use in adverse atmospheres

High strength, anti-static glass reinforced ABS housing is lightweight, corrosion proof and chemical resistant

Complete with filter, motor lubricator, exhaust muffler, air control valve and static grounding cord

Exhausts OUTSIDE of duct, compressed air not in airstream

IMPA Codes: AB7000 - 591511, 591425

Optional Accessories: Standard Duct, Anti-Static Duct, Duct Carrying Bags

AIR

MODEL afi75xx

order # ab7000

stoCk loCations

free air* 2,042cfm/3,471m3/hr

iMPeller 17-blade

DUCt aDaPter(s) 2

air ConsUMPtion 40cfm/68m3/hr

inDUCtion ratio 51:1

weigHt 38lbs/15kg

DiMensions (h/w/d)

16/17/16 in 410/430/410 mm

noise 89dB

Motor GAST 4AM-NRV-50C

aPProVals

* Measurements @ 80psig inlet air

Page 24: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

20 www.euramcosafety.com

HAZARDOUS WORKPLACE

MODEL RV760S RV760 RV1500

order # rV760s rV760 rV1500

stoCk loCations

inlet ConneCtion 0.5”/12.7mm NPT 0.5”/12.7mm NPT 1”/25.4mm NPT

flange API 3”/76.2mm (6.56”/167mm BC)

API 3”/76.2mm (6.56”/167mm BC)

API 6”/152.4mm (6.56”/167mm BC)

weigHt 5lbs/2kg 6lbs/3kg 19lbs/9kg

DiMensions (d/h)

5/16 in 127/406 mm

8/33 in 203/838 mm

12/42 in 305/1067 mm

aPProVals

40PSIG INLET AIR

free air 810cfm/1,377m3/hr 1,001cfm/1,702m3/hr 2,740cfm/4,658m3/hr

air ConsUMPtion 22cfm/37m3/hr 22cfm/37m3/hr 59cfm/100m3/hr

inDUCtion ratio 37:1 46:1 47:1

80PSIG INLET AIR

free air 1,180cfm/2,006m3/hr 1,439cfm/2,446m3/hr 3,329cfm/5,659m3/hr

air ConsUMPtion 58cfm/99m3/hr 58cfm/99m3/hr 124cfm/211m3/hr

inDUCtion ratio 20:1 25:1 27:1

optional static Cord

Venturi Cones | RV760S/RV760/RV1500 Safe for use in adverse or explosive atmospheres when used with optional static cord

Pneumatic (compressed air) or saturated steam powered Crush and dent resistant, anti-static, polyethylene cone Cylindrical mixing chamber delivers higher induction ratios Fits standard API 3”/7cm and 6”/15cm openings No moving parts Requires minimum maintenance IMPA Codes:

RV760S - 591430 RV760 - 591432 RV1500 - 591433

order # accessory

aZ-raC-10 Static Cord

AIR

Page 25: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 21

FIRE RESCUE

Page 26: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV

22 www.euramcosafety.com

®

Go the Distance with PowerStream® Traditional RAMFAN Turbo Ventilators certainly have their place. Tried and true, tested and trusted, they’ve been with you for five, ten, even 15 years. And they’ve never let you down. However, there comes a time when a new innovation in equipment technology makes you reconsider everything you’ve always thought about PPV.

PowerStream® technology, only from raMfanPowerStream® ventilation results from a state-of-the-art combination of a fan impeller and stator that takes the cone of air you’ve always used for PPV and tightens it to keep it focused over longer distances without losing significant power. PowerStream® is like going from a fog nozzle to straight bore. You still get the same, dependable flow of air to ventilate a structure, you can just do it from farther away.

PowerStream® technology: benefits of further setback distance 6–18ft/ 1.8–9.7m No more fans in your way while you get in and victims get out No more tripping over cords or kicking over fans Flexible positioning to get exactly the right spot for maximum performance Less interior noise to interfere with communications No other manufacturer can compete with our INDEPENDENTLY VERIFIED cfm and setback distances

PowerstreaM ConVentional

CLOSE RANGE:Both PowerStream®

and Conventional fans can operate

in close range of the door.

AT 18 FEET:Only PowerStream®

fans can be set back as far as 18

feet and be equally effective as 6 feet.

effective

effective

effective

not effective

PowerStream® PPV Blowers3-Year Warranty

Page 27: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 23

POWERSTREAM

How do you measure manufacturer claims of airflow delivery?

You may hear a lot about airflow rates on various pieces of equipment. While some manufacturers produce their own in-house ratings, others choose independent firms. The issue with self-rating is that there is no common reference point.

Take a simple standard like a ruler or yardstick. What would the world be like if everyone made their own “ruler”? You’d get a lot of variation, wouldn’t you? You really need a common reference point provided by an independent, unbiased organization to get a benchmark for a measurement. In the United States, the American National Standards Institute (ANSI) is one such group. In Europe, the European Committee for Standardization (CEN) is another.

The Air Movement and Control Association (AMCA) provides the benchmark for the ventilation industry. AMCA is a non-profit international association of manufacturers that develops standards and measures equipment airflow delivery rates on an independent and non-biased basis. They have testing facilities in both North America and Europe.

The AMCA 240 test procedure for positive pressure ventilators uses a standard 36“ x 72” door opening. Because larger diameter fans are constricted by the standard door opening, the AMCA test procedure can accurately measure airflow for fans up to 21” in diameter. Currently no standardized test procedure exists for larger fans. Fans larger than 21” require a greater structure opening than a standard single doors due to the wide cone of air.

The lesson here is that smart buyers ask for AMCA Certified Ratings. They don’t rely on manufacturer claims, which are difficult if not impossible to verify. If the fan company cannot provide an AMCA rating on their PPV equipment, you may find that their airflow is not what it’s claimed to be.

Page 28: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV POWERSTREAM

24 www.euramcosafety.com

16”/40cm | GX200 Lightest PPV Fan Ever – Only 48 lbs.!

PowerStream® Air Straighteners support greater setback distances up to 18 ft/ 6m reducing the noise level inside the building while allowing the entry/exit to keep clear of obstructions for advancing firefighters

Ultra Lightweight — Only 48lbs/22kg! GX200 has the Highest Airflow (12,800cfm) to Horsepower

(2.1Hp) Ratio on the market Honda GXH50 engine produces 56% Less CO than

comparable 5Hp engines Compact, for easy storage in typical engine compartments 7-Blade Polymer TurboForce™ Impeller for increased shatter

resistance and enhanced PPV performance Full-width Folding Handle for easy maneuvering WIDE-Trac Semi-Pneumatic Urethane Tires easily roll over

mud or rough terrain Welded, Unitized Steel Frame, off-road “Roll Cage” design

with wide footprint reduces vibration and lengthens service life. No bolts to shake loose!

ONE-Step™ Tilt Adjustment – easily change the angle of the fan from 0–18º in four precise steps. Fan can ventilate over steps, porches, slopes and other fireground obstacles

MODEL GX200

order # gg5010

stoCk loCations

PPV airflow 12,820cfm/21,794m3/hr

iMPeller 7-blade

weigHt 48lbs/22kg

DiMensions (h/w/d)

21.5/19.5/20.5 in 55/50/52 cm

noise 91dB@3ft/1m 86dB@10ft/3m

Motor Honda 2.1Hp/1.6kW GXH50

rUn tiMe 1hr 40min

aPProVals

CertifiCation AMCA

Page 29: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 25

MODEL GX310

order # gH5010

stoCk loCations

PPV airflow 16,968cfm/28,846m3/hr

iMPeller 9-blade

weigHt 82lbs/37kg

DiMensions (h/w/d)

21.6/21.7/19.6 in 55/55/50 cm

noise 100dB@3ft/1m 95dB@10ft/3m

Motor Honda 4.8Hp/3.5kW GX160

rUn tiMe 2hrs 6min

aPProVals

CertifiCation AMCA

18”/46cm | GX310 Versatile PPV Blower

PowerStream® Air Straighteners support greater setback distances up to 18ft / 6m reducing the noise level inside the building while allowing the entry/exit to keep clear of obstructions for advancing firefighters

PowerShroud® design combines the shroud, front fan guard, air straighteners, tilt handle and mister into a single unitized polycarbonate-abs shell for lighter weight and extreme durability. -30–120°F (-3–50°C) operating range

Compact, for easy storage in typical engine compartments 9-Blade Polymer TurboForce™ Impeller for increased shatter resistance and enhanced PPV performance

Full-width Folding Handle for easy maneuvering WIDE-Trac Semi-Pneumatic Urethane Tires easily roll over mud or rough terrain

Welded, Unitized Steel Frame, off-road “Roll Cage” design with wide footprint reduces vibration and lengthens service life. No bolts to shake loose!

ONE-Step™ Tilt Adjustment – easily change the angle of the fan from 0–18º in four precise steps. Fan can ventilate over steps, porches, slopes and other fireground obstacles

Optional Accessories: Integrated Misting System, Hour Meter,BIGbore™ Exhaust Diverter

POWERSTREAM

Page 30: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV

26 www.euramcosafety.com

MODEL GX350

order # gH5005

stoCk loCations

PPV airflow 18,705cfm/31,799m3/hr

iMPeller 9-blade

weigHt 84lbs/38kg

DiMensions (h/w/d)

21.6/21.7/19.6 in 55/55/50 mm

noise 101dB@3ft/1m 97dB@10ft/3m

Motor Honda 5.5Hp/4.1kW GX200

rUn tiMe 1hr 50min

aPProVals

CertifiCation AMCA

18”/46cm | GX350 Most Versatile PPV Blower in its Class

PowerStream® Air Straighteners support greater setback distances up to 18ft / 6m reducing the noise level inside the building while allowing the entry/exit to keep clear of obstructions for advancing firefighters

PowerShroud® design combines the shroud, front fan guard, air straighteners, tilt handle and mister into a single unitized polycarbonate-abs shell for lighter weight and extreme durability. -30–120°F (-35–50°C) operating range

Compact, for easy storage in typical engine compartments 9-Blade Polymer TurboForce™ Impeller for increased shatter

resistance and enhanced PPV performance Full-width Folding Handle for easy maneuvering WIDE-Trac Semi-Pneumatic Urethane Tires easily roll over

mud or rough terrain Welded, Unitized Steel Frame, off-road “Roll Cage” design

with wide footprint reduces vibration and lengthens service life. No bolts to shake loose!

ONE-Step™ Tilt Adjustment – easily change the angle of the fan from 0–18º in four precise steps. Fan can ventilate over steps, porches, slopes and other fireground obstacles

Optional Accessories: Integrated Misting System, Hour Meter,BIGbore™ Exhaust Diverter

POWERSTREAM

Page 31: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 27

MODEL GX400 GX400

order # ge5022 ge5010

stoCk loCations

PPV airflow 16,797cfm/28,555m3/hr 16,797cfm/28,555m3/hr

iMPeller 7-blade 7-blade

weigHt 88lbs/40kg 94lbs/43kg

DiMensions (h/w/d)

24.9/25/22 in 63/64/56 cm

24.9/25/22 in 63/64/56 cm

noise 99dB@3ft/1m 95dB@10ft/3m

99dB@3ft/1m 95dB@10ft/3m

Motor Honda 5.5Hp/4.1kW GX200 Vanguard 6.5Hp/4.8kW 13L333

rUn tiMe 1hr 50min 1hr 50min

aPProVals

CertifiCation AMCA –

21”/54cm | GX400 High Power PPV for ANY Building

PowerStream® Air Straighteners support greater setback distances up to 18ft/6m reducing the noise level inside the building while allowing the entry/exit to keep clear of obstructions for advancing firefighters

Compact, for easy storage in typical engine compartments 7-Blade Polymer TurboForce™ Impeller for increased shatter

resistance and enhanced PPV performance Full-width Folding Handle for easy maneuvering WIDE-Trac Semi-Pneumatic Urethane Tires easily roll over

mud or rough terrain Welded, Unitized Steel Frame, off-road “Roll Cage” design

with wide footprint reduces vibration and lengthens service life. No bolts to shake loose!

ONE-Step™ Tilt Adjustment – easily change the angle of the fan from 0–18˚ in four precise steps. Fan can ventilate over steps, porches, slopes and other fireground obstacles

Optional Accessories: Integrated Misting System, Hour Meter, BIGbore™ Exhaust Diverter

POWERSTREAM

Page 32: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV POWERSTREAM

28 www.euramcosafety.com

MODEL EX400 (Dual Current) EX420

order # eb80600 eb88245

stoCk loCations

PPV airflow 9,989cfm/16,981m3/hr 10,994cfm/18,690m3/hr

iMPeller 7-blade 7-blade

weigHt 68lbs/31kg 68lbs/31kg

DiMensions (h/w/d)

22.6/17.4/18.5 in 57/44/47 cm

22.6/17.4/18.5 in 57/44/47 cm

noise 88dB@3ft/1m 84dB@10ft/3m

88dB@3ft/1m 84dB@10ft/3m

Motor 1.5Hp/1.1kW 1.5Hp/1.1kW

eleCtriC 115V, 1ø, 15 or 20A, 60Hz 230V, 1ø, 10A, 50/60Hz

aPProVals –

CertifiCation AMCA –

16”/ 40cm | EX400/EX420 Variable Speed Turbo Blower

Equipped with PowerStream® to support greater setback distances reducing the noise level inside the building and allows the entry/exit to keep clear of obstructions for advancing firefighters.

IntelliSense™ water-resistant variable speed controls deliver continuous airflow adjustment from zero to maximum speed.

Model EX400 with dual current feature. With the flip of a toggle switch, power fan from GFCI 20A fire truck circuit to GFCI 15A house circuit or start from 2kW generator by controlling in-rush current.

7-blade polymer TurboForce™ impeller for increased shatter resistance and enhanced PPV performance.

1”/25mm powder coated steel frame with all-terrain semi-pneumatic tires

Full-width retractable handle for upright, push/pull operation 0–20º tilt adjustment for fast, easy set-up

Optional Accessories: Standard Duct, Disposable Duct, Layflat Duct, Duct Carrying Bags

Page 33: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 29

18”/46cm | EX500/EX520 Variable Speed Ventilator

Equipped with PowerStream® to support greater setback distances reducing the noise level inside the building and allows the entry/exit to keep clear of obstructions for advancing firefighters.

PowerShroud® design combines the shroud, front fan guard, air straighteners, tilt handle and mister into a single unitized polycarbonate-abs shell for lighter weight and extreme durability. -30–120ºF operating range

Model EX500 with dual current feature. With the flip of a toggle switch, power fan from GFCI 20A fire truck circuit to GFCI 15A house circuit or start from 2kW generator by controlling in-rush current.

Compact, for easy storage 5-Blade polymer Turbo-Force™ impeller for increased shatter

resistance and enhanced PPV performance 1”/25mm powder coated steel frame with all-terrain semi-

pneumatic tires Full-width retractable handle for upright, push/pull operation 0–20º tilt adjustment for fast, easy set-up

Optional Accessories: Integrated Misting System

POWERSTREAM

MODEL EX500 (Dual Current) EX520

order # ek86500 ek86520

stoCk loCations

PPV airflow 11,540cfm/19,618m3/hr 13,354cfm/22,702m3/hr

iMPeller 5-blade 5-blade

weigHt 70lbs/32kg 70lbs/32kg

DiMensions (h/w/d)

23.5/21/18.5 in 60/53/47 cm

23.5/21/18.5 in 60/53/47 cm

noise 95dB@3ft/1m 91dB@10ft/3m

95dB@3ft/1m 91dB@10ft/3m

Motor 1.5Hp/1.1kW 1.5Hp/1.1kW

eleCtriC 115V, 1ø, 15 or 20A, 60Hz 230V, 1ø, 10A, 50/60Hz

aPProVals –

CertifiCation AMCA AMCA

Page 34: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV

30 www.euramcosafety.com

Page 35: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 31

POWERSTREAM

MODEL XP500 XP520

order # eb90600X eb90600X-230

stoCk loCations

PPV airflow 11,540cfm/19,618m3/hr 13,354cfm/22,702m3/hr

iMPeller 5-blade 5-blade

weigHt 72lbs/33kg 72lbs/33kg

DiMensions (h/w/d)

23.5/21/18.5 in 60/53/47 cm

23.5/21/18.5 in 60/53/47 cm

noise 97dB@3ft/1m 95dB@10ft/3m

97dB@3ft/1m 95dB@10ft/3m

Motor 1.5Hp/1.1kW 1.5Hp/1.1kW

eleCtriC 115V, 1ø, 15A, 50/60Hz 230V, 1ø, 8A, 50/60Hz

aPProVals –

18”/46cm | XP500/XP520 Exposion Proof Ventilator

ATEX certified motor is completely enclosed for safe use in dangerous atmospheres

Purges hazardous or explosive gases safely 5-Blade polymer TurboForce™ impeller for increased shatter

resistance and enhanced PPV performance Equipped with PowerStream® to support greater setback distances reducing the noise level inside the building and allowing the entry/exit to keep clear of obstructions for advancing firefighters

1”/25mm powder coated steel frame with all-terrain semi-pneumatic tires

Full width retractable handle for upright, push/pull operation 0–20˚ tilt adjustment for fast, easy set-up

Page 36: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV POWERSTREAM

32 www.euramcosafety.com

Water Powered Turbo Blowers

First Choice of Naval Forces Worldwide

RAMFAN Water Powered Turbo Blowers are used by Naval Forces worldwide for smoke removal, ventilation and cooling during combat operations.

21”/54cm | WF540 Solution to High Rise Underground and Warehouse Ventilation

Water powered, intrinsically safe 6-blade polymer TurboForce™ impeller for increased shatter

resistance and enhanced PPV performance. Water control valve provides direct control of airflow at blower Outlet for water recycling (closed circuit) to conserve water supply Wide range tilt adjustment Powder coated steel frame with full-width folding handle Equipped with PowerStream® to support greater setback distances reducing the noise level inside the building and allows the entry/exit to keep clear of obstructions for advancing firefighters.

Integral misting system

Optional Accessories: Many water connection fittings and ducting configurations available. Call for details.

MODEL WF540

order # wD5010

stoCk loCations

PPV airflow 22,443cfm@150psi 38,154m3/[email protected]

iMPeller 7-blade

weigHt 75lbs/34kg

DiMensions (h/w/d)

25.6/24.8/20.9 in 650/630/530 mm

Motor 5.2Hp@150psi [email protected]

PressUre/flow nominal: 0.8MPa/471lpm 116psi/124gpm Max: 250psi/70gpm 250psi/221gpm

aPProVals

Page 37: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 33

16”/40cm | WF390L High Volume PPV Blower Water powered 7-blade polymer TurboForce™ impeller for increased shatter resistance

and enhanced PPV performance. Outlet for water recycling (closed circuit) to conserve water supply Wide range tilt adjustment Powder coated steel frame Equipped with PowerStream® to support greater setback distances reducing the noise level inside the building and allows the entry/exit to keep clear of obstructions for advancing firefighters.

Lightweight, easy to maneuver Optional mister attachment Full-width retractable handle and heavy-duty wheels for upright,

push-pull operation

Optional Accessories: Many water connection fittings and ducting configurations available. Call for details.

MODEL WF390L

order # wb5001lb (bsP)/wb5001lnH (nH)/wb5001Din

stoCk loCations

PPV airflow 17,417cfm@150psi 29,610m3/[email protected]

weigHt 60lbs/27kg

DiMensions (h/w/d)

22.8/16.9/16 in 580/430/410 mm

Motor 10Hp@250psi [email protected]

PressUre/flow nominal: 150psi/96gpm 0.8MPa/362lpm Max: 250psi/162gpm 1.75MPa/612lpm

aPProVals

CertifiCation AMCA

safer...

RAMFAN’s water powered design eliminates the threat of electrical shock and minimizes explosion potential in dangerous gas environments.

More efficient..

RAMFAN’s patented Axial Flow Turbine Technology leads the way in converting water power into high velocity airflow more efficiently than any water fan on the market today.

better...

RAMFAN’s axial turbine is bult of corrosion-proof composite materials for long life, simple maintenance and easy replacement of parts.

POWERSTREAM

Page 38: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV

34 www.euramcosafety.com

TURBOFORCE

RAMFAN “Fast Attack” Turbo Blowers The FORCE to Clear…The FORCE to CoolRAMFAN fast attack blowers use turbine fan technology to generate a stronger, faster and more focused airflow than possible with conventional propeller designs. Today, fires burn hotter and faster, and advances in protective equipment allow more aggressive fire attack with rapid advance into hot, smoky and dangerous conditions. Fast intervention is the key to rapid knockdown and a RAMFAN fast attack blower is the perfect partner to cool and clear the way.

why turbo technology?Blower output or CFM is only half the story. A faster, more penetrating FORCE of air means faster cooling and clearance of dangerous smoke and toxic gas. Turbo blowers accelerate the airflow to much greater velocities than conventional propeller fans. The kind of velocity that will churn and upset the thermal balance of an involved structure dropping the heat and mixing it with cool outside air and stripping the smoke off the ceiling and propelling it out.

a more focused airflow shape penetrates deeply into layers of super-heated gas, disturbing stratification, dropping temperature and improving visibility much quicker than a conventional blower with the same or even greater airflow. low velocity flow does not have the kinetic energy necessary to penetrate and mix.

forCe = greater VelocityRAMFAN “Fast Attack” Turbo Blowers rely on the FORCE of a high energy focused air stream to breakdown thermal layering, mixing cool outside air with the dangerous products of combustion which accelerates cooling and clearing. The focused discharge stream of air is unlike that of a conventional propeller design. The high-energy focused center core of air is much more effective in “fast attack” fire fighting operations.

the turbo blade Design is the Critical DifferenceThe turbo fan blade is modeled after a modern jet engine compressor. The RAMFAN design is made specifically for high-speed, high-velocity operation. The large number of short, twisted blades on a large diameter hub means higher pressure, higher velocity and safer operation. The wide hub and its conical mount decrease the effects of engine blockage; resulting in high airflow from a small, compact blower design.

A Faster, More Penetrating FORCE Means Faster Cooling and Clearance of Dangerous Smoke and Toxic Gases

Propeller FanVelocity Profile

Turbo BlowerVelocity Profile

Propeller Airflow Turbo Airflow

Less focused, diffused airflowproduces good CFM but low velocity.

The FORCE penetrates and churns for faster cooling and clearing.

m3/h Comparison Velocity Comparison

RAMFAN Turbo Blower

Propeller Fan

RAMFAN Turbo Blower

Propeller Fan

20% MORE

Page 39: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 35

MODEL GF164SE

order # gb5001Hse

stoCk loCations

PPV airflow 11,653cfm/19,810m3/hr

iMPeller 7-blade

rUn tiMe 1hr 58min

weigHt 59lbs/27kg

DiMensions (h/w/d)

21/20/17 in 533/508/432 mm

noise 96.1dB

Motor Honda GC160 4.6Hp/3.4kW

aPProVals

CertifiCation AMCA

16”/40cm | GF164SE Turbo Blower

7-blade polymer TurboForce™ impeller for increased shatter resistance and enhanced PPV performance (not shown in picture).

Economical choice for outstanding PPV ventilation

1”/25mm powder coated steel frame 5-position rapid tilt feature for fast, easy

set-up Compact and lightweight for easy lifting

and storage

Optional Accessories: Cooling Collar, BIGbore™ Exhaust Diverter, 16” Multi-purpose Accessory Pack

TURBOFORCE

Page 40: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

FIRE RESCUE | PPV

36 www.euramcosafety.com

TURBOFORCE

16”/40cm | GF165 Turbo Blower

21-blade polymer TurboForce™ impeller for increased shatter resistance and enhanced PPV performance.

Compact design fits fire truck compartments 1”/25mm powder coated steel

full-perimeter frame ONEstep™ tilt feature for fast, easy set-up Full-width folding handle for easy

maneuvering Honda GX-series engine with oil alert

Optional Accessories: Cooling Collar, BIGbore™ Exhaust Diverter, 16” Multi-purpose Accessory Pack

MODEL GF165

order # ga5006

stoCk loCations

PPV airflow 12,906cfm/21,940m3/hr

iMPeller 21-blade

rUn tiMe 126min

weigHt 84lbs/38kg

DiMensions (h/w/d)

22/20.2/20 in 559/513/508 mm

noise 96.2dB

Motor Honda GX160 4.8Hp/3.5kW

aPProVals

CertifiCation AMCA

Page 41: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 37

TURBOFORCE

RAMFAN’s fire fighting PPV Series outperforms larger blowers in their class with their precision balanced TurboForce Impellers that maximize airflow. These PPV blowers have proven to be effective in controlling airborne contaminates, replacing interior air, removing heat and supplementing fixed ventilation systems. By pressurizing properly and controlling the resultant flow path, these changes occur very rapidly. This is accomplished by using these specialized blowers with the power and velocity to pressurize the interior of a structure or building.

Page 42: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

38 www.euramcosafety.com

FIRE RESCUE | LSV

Large Structure Ventilators (LSV) come of age as online commerce grows Online retailing today is filling warehouses everywhere with products. Adding these to the current inventory of big box stores, airports, high-rises and hotels, the need for tools to fight large structure fires is clear.

These large structures require massive PPV ventilation because you can’t support fireghting operations in a large structure with small structure equipment.

one huge fan doesn’t make sense anymore.

Until now, Large Structure Ventilators have been huge monsters that are difficult to move and maneuver, which can limit access to the structure on fire. They require a large storage space and have price tags that are budget-busters. This limits most cities to a single unit for the entire area.

RAMFAN LSV’s are the solution to these problems. The largest LSV is a 28” trailer mounted fan that is small enough for one person to maneuver but powerful enough to quickly pressurize a highrise stairwell and is offered at a price point so low you can buy 6 LSV’s for every one truck mounted fan.

Houston, Texas

Houston, Texas

when it comes to equipment access which would you prefer: a single hub or a distributed network?If your city owns one large truck mounted fan stored in a central location and you respond to a warehouse fire on the outskirts of the city the reponse time may be too long to get the equipment to the scene. But if you had a distributed network of large fans it would cut the response time in less than half.

Houston, texas

=

$

$ $

$

$

$

$

Page 43: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 39

24”/60cm | GX500 For Warehouses, Malls & Light Industry

PowerStream® Air Straighteners support greater setback distances up to 18ft / 6m reducing the noise level inside the building while allowing the entry/exit to keep clear of obstructions for advancing firefighters

7-Blade Polymer TurboForce™ Impeller for increased shatter resistance and enhanced PPV performance

Full-width Folding Handle for easy maneuvering WIDE-Trac Semi-Pneumatic Urethane Tires easily roll over mud or rough terrain

Welded, Unitized Steel Frame, off-road “Roll Cage” design with wide footprint reduces vibration and lengthens service life. No bolts to shake loose!

ONE-Step™ Tilt Adjustment – easily change the angle of the fan from 0–18º in four precise steps. Fan can ventilate over steps, porches, slopes and other fireground obstacles

Optional Accessories: Integrated Misting System, Hour Meter,BIGbore™ Exhaust Diverter

MODEL GX500

order # gD5005

stoCk loCations

PPV airflow 19,069cfm/32,417m3/hr

iMPeller 7-blade

weigHt 137lbs/62kg

DiMensions (h/w/d)

30/29/26.7 in 76/74/68 cm

noise 100dB@3ft/1m 96dB@10ft/3m

Motor Honda 8.5Hp/6.3kW GX270

rUn tiMe 2hr 2min

aPProVals

Page 44: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

40 www.euramcosafety.com

FIRE RESCUE | LSV

28”/70cm | GX600 Ideal for Large Commercial Structures

PowerStream® Air Straighteners support greater setback distances up to 18ft / 6m reducing the noise level inside the building while allowing the entry/exit to keep clear of obstructions for advancing firefighters

7-Blade Polymer TurboForce™ Impeller for increased shatter resistance and enhanced PPV performance

Full-width Folding Handle for easy maneuvering Four lifting handles for easy loading/unloading WIDE-Trac Semi-Pneumatic Urethane Tires easily roll

over mud or rough terrain Welded, Unitized Steel Frame, off-road “Roll Cage”

design with wide footprint reduces vibration and lengthens service life. No bolts to shake loose!

ONE-Step™ Tilt Adjustment - easily change the angle of the fan from 0–18º in four precise steps. Fan can ventilate over steps, porches, slopes and other fireground obstacles

Integrated misting system

MODEL GX600

order # gJ5005

stoCk loCations

PPV airflow 32,500cfm/55,250m3/hr

iMPeller 7-blade

weigHt 175lbs/80kg

DiMensions (h/w/d)

34.5/37.3/30.3 in 88/95/77 cm

noise 105dB@3ft/1m 103dB@10ft/3m

Motor Vanguard 18Hp/13.4kW V-Twin OHV mod. 35

rUn tiMe 2 hrs 40min

Page 45: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 41

28”/70cm | VX700 LSV Large Structure Ventilator

Designed for high-rises, malls, apartments, warehouses and other large-scale structures

Built-in skids, optional trailer PowerStream® ventilation provides setback distance of 20–32’ from door!

Fan tilt angle of -5º to +18º Powerful Honda V-Twin GX630 engine with oil alert protection, electric start, 12VDC system with 17A alternator

Amber beacon light and overhead equipment light

4 Gallon/15 Liter EPA & CARB certified fuel tank for 2.5 hours of run time

Battery Indicator displays charge level Hour Meter tracks maintenance schedules Integral 8-nozzle water mister Hose fittings provide adaptability. BSP and NPSH inlet water fittings

Optional Accessories: BIGbore™ Exhaust Diverter

MODEL VX700 VX700 w/ Trailer VX700 w/ Trailer

order # gk5000 (skid Mounted) gk5005 (trailer Mounted) gk5010 (trailer Mounted)

stoCk loCations

PVV airflow 46,700–60,200cfm 79,390–105,400m3/hr

46,700–60,200cfm 79,390–105,400m3/hr

79,390–105,400m3/hr

weigHt 220lbs/100kg 920lbs 420kg

DiMensions (h/w/d)

49/33.3/47.3 in 1,240/850/1,200 mm

79.75/58/124 in 2,046/1,520/3,204 mm

Motor Honda GX630 23Hp/17kW Honda GX630 23Hp/17kW Honda GX630 23Hp/17kW

aPProVals

Page 46: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

42 www.euramcosafety.com

FIRE RESCUE | Smoke Ejector

MODEL EFC50 EFC120 (50Hz) EFC150

order # ea7000, ea7000-230 ea7300 eg8000, eg8000-230

stoCk loCations

free air15ft/4.6m 1-90° turn

3,200cfm/5,440m3/hr 1,935cfm/3,289.5m3/hr

3,750cfm/6,375m3/hr 2,700cfm/4,590m3/hr

4,459cfm/7,580.3m3/hr 3,179cfm/5,404.3m3/hr

iMPeller 21-blade 7-blade 7-blade

DUCt aDaPter(s) 0 2 0

weigHt 46lbs/21kg 53lbs/24kg 55lbs/25kg

DiMensions (h/w/d)

19/18/12 in 483/457/305 mm

19/18/16 in 483/457/407 mm

19/18/12 in 483/457/305 mm

noise 90.2dB 86.1dB 90.2dB

Motor 0.5Hp/0.37kW 1.2Hp/0.9kW 1.5Hp/1.1kW

eleCtriC 115/230VAC, 1ø, 50/60Hz 240VAC, 1ø, 50Hz 115/230VAC, 1ø, 50/60Hz

aMPs – start – rUn

115V: 21A 230V: 10A 115V: 6A 230V: 3A

27A 5A

115V: 80A 230V: 40A 115V: 15A 230V: 8A

aPProVals –

16”/40cm | EFC50/EFC120/EFC150 Smoke Ejectors

New polymer TurboForce™ impeller for increased shatter resistance and enhanced performance

Built for smoke ejection in confined spaces High velocity flow decreases smoke ejection time dramatically

High-impact, heat resistant Lexan® polycarbonate housing with 4-corner handles for fast set-up and storage

Lightweight, compact design stacks easily Optional tilt bracket available – see page 49 Stackable for easy storage Plug sold separately – see page 50 for

plug options

Optional Accessories: Standard Duct, Layflat Duct, Duct Adapters, Duct Carrying Bags, 16” Multi-Purpose Accessory Pack, Door Bar and Hanger Kit

efC120

Page 47: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 43

MODEL EFC50x EFC120x (50Hz) EFC150x

order # ea7000X, ea7000X-230 ea7300X eg8000X, eg8000X-230

stoCk loCations

free air15ft/4.6m 1-90° turn

3,200cfm/5,440m3/hr 1,935cfm/3,289.5m3/hr

3,750cfm/6,375m3/hr 2,700cfm/4,590m3/hr

4,459cfm/7,580m3/hr 3,179cfm/5,404m3/hr

iMPeller 21-blade 7-blade 7-blade

DUCt aDaPter(s) 0 2 2

weigHt 49lbs/22kg 51lbs/23kg 55lbs/25kg

DiMensions (h/w/d)

19/18/12 in 483/457/305 mm

19/18/16 in 483/457/407 mm

19/18/16 in 483/457/407 mm

noise 90.2dB 86.1dB 90.2dB

Motor 0.5Hp/0.37kW 1.2Hp/0.9kW 1.5Hp/1.1kW

eleCtriC 115/230VAC, 1ø, 50/60Hz 230VAC, 1ø, 50Hz 115/230VAC, 1ø, 50/60Hz

aMPs – start – rUn

115V: 21A 230V: 10A 115V: 6A 230V: 3A

27A 5A

115V: 80A 230V: 40A 115V: 15A 230V: 8A

aPProVals

LR66789

16”/40cm | EFC50x/EFC120x/EFC150x Intrinsically Safe Turbo Blowers

UL and ATEX Certified Motors for safe use in adverse atmospheres

High-impact, heat resistant Lexan® polycarbonate housing with 4-corner handles for fast set-up and storage

Built for smoke ejection in hazardous conditions and confined spaces

High velocity flow decreases de-smoking time dramatically

Lightweight, compact design stacks easily Optional tilt bracket available – see page 49 Plug sold separately – see page 50 for plug options

Optional Accessories: Anti-Static Duct, Layflat Duct, Duct Carrying Bags, 16” Multi-Purpose Accessory Pack, Door Bar and Hanger Kit efC150x

Page 48: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

44 www.euramcosafety.com

FIRE RESCUE | Marine/Military

SPECIFICATIONS

order # wa5001bsP/wa5001nH/ wa5001n(nPsH)

DUCteD air flow @ 150psi 1,835cfm/3,120m3/hr

weigHt 35lbs/15.9kg

DiMensions (h/w/d)

16/12/12 in 400/310/310 mm

Power 4.6Hp/3.4kW @150psi 8Hp/6kW @250psi

PressUre/flow Min: 40psi/29gpm Max: 250psi/94gpm

ConneCtions 1.5”/3.8cm NST (NH), NPSH, or BSP male connections

CertifiCations U.S. Navy Test Report

8”/20cm | WF20 Water Powered PPV Turbo Blower

Standard for U.S. Navy, Royal Navy, French, ANZAC, others

Operates from the fire mains and overboard drainage

4.6Hp @ 150psi water pressure Intrinsically safe, non-electrical Dual purpose: Ducted and PPV-mist cooling

Sta

tic

Pres

sure

– In

ches

H20

16

Airflow Capacity – CFM

14

12

10

8

6

4

2

0

180 psi

150 psi

40 psi

60’8” ducton discharge

200’12” ducton discharge

200 400 600 800 1000 1200 1400 1600 1800 2000 2200

wf20 Performance

water/air couplings to customer specifications

french british Usa

DUCTING ACCESSORIES

Description order #

Duct – Neoprene CoatedUS Navy Standard (10”x15’)/(25cmx4.6m)

Dt-1015DVi-3

Duct – Neoprene CoatedUS Navy Standard, long (10”x25’)/ (25cmx7.6m)

Dt-1025DVi-3

Wire Reinforced Duct w/ storage bag AFNOR DN 300 cplgs (30cmx5m)

wa0721

Duct Adapter, 10”/25cm with Snap-Lock – 2 required/blower

wa0411

Duct Adapter, 12”/30cm for use with belted duct – 2 required/blower

wa0511

Duct Adapters (2 included)AFNOR DN 300 Type M (French Norm)

wa0711

Kit – U.S. Navy version Blower w/ (4) Duct(DT-1015DVI-3) & (2)10” adapters

4140-01-333-2224

wf20 - Ducted

Page 49: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 45

No portable blower in the world compares with the smoke removal rates of the WF20 connected to ducting from 8” to 12”. Warships at general quarters require powerful suction to remove smoke from interior spaces. The WF20 suctions the smoke from the affected areas through long lengths of ducting to the outside air. At normal fire main pressures of 125 to 150psi, the WF20 makes about 4.5Hp with a 50gpm flow rate.

The WF20 blower uses the water pressure energy of a fire hose and a patented turbine, coupled to a high-efficiency fan blade, to generate high-velocity, high-pressure airflows. The modular construction, choice of corrosion-resistant materials and simplicity assures infrequent and simple maintenance.

Exhaustive testing during U.S. Navy evaluations left the WF20 as the uncontested champion of shipboard de-smoking.

The Safest and Most Powerful Portable Ventilator in the World

Add the Multiplier/Mister

wf20 - Multiplier/Mister - PPV

PPV AIRFLOW

free air @ 150psi 13,125cfm/22,313m3/hr

free air @ 250psi 16,511cfm/28,069m3/hr

MULTIPLIER/MISTER ACCESSORIES

Description order #

Multiplier/Mister wa0802

AFNOR Multiplier/Mister w/ ZAG AdapterAFNOR DN 300 Type M (French)

wa0711

Strainer Adapter for use with BIC, Guillemin and Storz Couplings

wa2810

Multiplier/Mister ZAG Adapter AFNOR DN 300 Type M (French Norm)

ZagaY-2

Venturi device doubles airflow Injects 3.5 gpm of water into airflow Use as PPV blower Intrinsically safe in hazardous conditions

The Multiplier/Mister Attachment injects up to 3.5 gpm into the airstream producing a cooling mist. This has proven beneficial in creating heat migration boundaries, cooling of personnel and even catapults and aircraft wheels.

Page 50: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

46 www.euramcosafety.com

FIRE RESCUE

Page 51: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 47

ACCESSORIES

Page 52: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

48 www.euramcosafety.com

ACCESSORIES

Standard Duct – 15’/4.6m & 25’/7.6m ECKO-flex non-collapsible, reinforced duct 8”/20cm, 12”/30cm or 16”/40cm diameter sizes Flame retardant IMPA codes available for ducting, please call to inquire

Anti-Static Duct – 15’/4.6m & 25’/7.6m Non-collapsible, reinforced duct Safely conducts electricity to the ground circuit of the blower Surface resistance less than 6 Gø 8”/20cm, 12”/30cm and 16”/40cm diameter sizes Flame retardant IMPA codes available for ducting, please call to inquire

Disposable Duct – 100’/30.5m Disposable, layflat polyethylene duct No reinforcement, 4mil thick 12”/30cm and 16”/40cm diameter sizes are sold by the foot

Layflat Duct 25’/7.6m Fiber reinforced, collapsible duct 16”/40cm diameter sizes 16”/40cm duct available with a 90° elbow, 4’x10’ Elbow Order No. FDT-L4X10SME

Cooling Collars/Misters – 16”/40cm Blowers Quickly cool and rehabilitate with a cooling collar Fits around duct adapter of blower injecting mist into airflow Designed for use with a garden hose Water output per hour is based on water pressure

16”/40cm Multi-Purpose Accessory Pack Multi-purpose solution for ventilation. Layflat storage bag includes:

- 16”/ 40cm Cooling Collar - 16”/ 40cm Unreinforced Layflat Duct (25’/ 7.6m) - 16”/ 40cm 90° Unreinforced duct 4’/1.2m x 10’/3m

Page 53: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 49

BIGbore™ Exhaust Diverter Diverts engine exhaust away from the work environment 2”/5cm diameter flexible, galvanized hose reduces engine

backpressure Quick connect fittings meet DIN standards Additional hose available to extend exhaust diversion

Door Bar and Hanger Kit Suspend smoke ejector box fans in doorway or window for more efficient ventilation

Compatible with all EFi and EFC-series fans

Tilt Bracket Provides full 360° rotation for ultimate freedom to direct air where you want

Compatible with all EFi and EFC-series fans

Duct Carrying Bagsorder # includes

bg12 Storage Bag for 8”/20cm x 15’/4.6m or 25’/7.6m Duct and for 12”/30cm x 25’/7.6m Duct

bg12s Storage Bag for 12”/30cm x 15’/4.6m Duct

bg16 Storage Bag for 16”/40cm Duct

Duct Couplers and Adapters/Reducersorder # includes

DC8 8”/20cm Duct Coupler Stainless HD

DC12 12”/30cm Duct Coupler Stainless HD

DC16 16”/40cm Duct Coupler Stainless HD

eD0304 8”/20cm Inlet Duct Adapter for UB20

ef0304X 8”/20cm Anti-Static Inlet Duct Adapter for UB20xx

eC0301 12”/30cm to 8”/20cm Duct Adapter/Reducer

ea7116 16”/40cm Duct Adapter

Misting Systemsorder # system includes

gH8111 18”/46cm Mister for Models GX350

ge8111 21”/54cm Mister for Models GX400

gD8111 24”/60cm Mister for Models GX500

gJ8111 28”/70cm Mister for Model GX600

eb8111 16”/40cm Mister for Models EX400/420, EV400/420

Page 54: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

50 www.euramcosafety.com

ACCESSORIES

Plug Options

adapter order # system includes frequency amps Max. Volts

eZ-0721671 Twistlock Adapter 5-15P to L5-20R 60 20 125

eZgfi GFI Receptacle 60 15 125

eZ-5-15P NEMA 60 15 125

eZ-6-15P NEMA 60 15 250

eZ-5-20P NEMA 60 20 125

eZ-l5-15P NEMA Twistlock 60 15 125

eZ-l5-20P NEMA Twistlock 60 20 125

eZ-l5-30P NEMA Twistlock 60 30 125

eZ-l6-20P NEMA Twistlock 60 20 250

eZ-l6-30P NEMA Twistlock 60 30 250

eZ-70141-HD Schuko Plug, Heavy Duty 50 16 200-250

eZ-999-21000 Non-ATEX Splash Proof Schuko, Euro Standard 50 16 100-130

eZ-999-21001 Non-ATEX Splash Proof Schuko, Euro Standard 50 16 200-250

ateX CertifieD PlUgs

eZ-atX96430 ATEX Haz Loc Splash Proof Schuko, Euro Standard 50/60 16 100-130

eZ-atX96433 ATEX Haz Loc Splash Proof Schuko, Euro Standard 50/60 16 200-250

eZ-UgP15231 Killark Haz Loc 60 15 125

Power Component substitution: Euramco Safety can install any specified plug or length of cord for your specific application.

Page 55: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 51

Quick Reference Order Guide

inDUstrial/ ConfineD sPaCe

HaZarDoUs loCation

sMoke reMoVal

aCCessories Model order # Model order # Model order #

standard Duct 15’/ 4.6m and 5m UB20

EFI50/120/150UB30

FDT-2162- 4046BRFDT-1615BRFDT-3053 4005BB

AFi75xx AFi50xx

FDT-1215BB FDT-1615BR

EF390/400EV400/420 EFC50/120/150 WF390LEX400/420

FDT-1615BR FDT-1615BR FDT-1615BR FDT-1615BR FDT-1615BR

standard Duct 15’/ 7.6m and 10m UB20

EFI50/120/150UB30

FDT-2162- 4046BRFDT-1615BRFDT-3053 4010BB

AFi75xx AFi50xx

FDT-1225BB FDT-1625BR

EF390/400EV400/420 EFC50/120/150 WF390LEX400/420

FDT-1625BB FDT-1625BB FDT-1625BB FDT-1625BB FDT-1625BR

anti-static Duct 15’/ 4.6m UB20xx EFi75xx EFi50xx/120xx EFi150xx AFi75xx AFi50xx

FDT-0815CBB FDT-1215CBB FDT-1615CBR FDT-1615CBR FDT-1215CBB FDT-1615CBR

EFC50x/120x/ 150x

FDT-1615CBR

anti-static Duct 25’/ 7.6m UB20xx EFi75xx EFi50xx/120xx EFi150xx AFi75xx AFi50xx

FDT-0825CBB FDT-1225CBB FDT-1625CBR FDT-1625CBR FDT-1225CBB FDT-1625CBR

EFC50x/120x/ 150x

FDT-1625CBR

Disposable Duct – 100’ EFi50/120/150 FDT-16DISP EF390/400 EV400/420 WF390L GX200GF164SE GF165 EX400/420

FDT-16DISP FDT-16DISP FDT-16DISP FDT-16DISP FDT-16DISP FDT-16DISPFDT-16DISP

layflat Duct 25’/ 7.6m EFi50/120/150 UB30

FDT-1625SME FDT-1225SME

EF390/400 EV400/420 EFC50/150/120 EFC50x/120x/ 150x WF390L GX200 GF164SE GF165 EX400

FDT-1625SME FDT-1625SME FDT-1625SME FDT-1625SME FDT-1625SME FDT-1625SME FDT-1625SME FDT-1625SME FDT-1625SME

Continued on next page

Page 56: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

52 www.euramcosafety.com

ACCESSORIES

Quick Reference Order Guide, Continued

inDUstrial/ ConfineD sPaCe

HaZarDoUs loCation

sMoke reMoVal

aCCessories Model order # Model order # Model order #

Cooling Collar EV400/420 GF210WF390L

ED-MIST16GFMKWFMK

16”/40cm Multi-Purpose accessory Pack EFi50/120/150 BG16LFA EFi50xx/120xxEFi150xxAFi50xx

BG16LFABG16LFABG16LFA

GF164SE/165EF390/400EV400/420EFC50/120/150EFC50x/120x/ 150xEX400/420

BG16LFABG16LFABG16LFABG16LFABG16LFA

BG16LFA

bigbore™ exhaust Diverter GF164SE GF165GX200GX350GX400GX500

GF7110-CZGF7110-BZGF7110-KZGF7110-GZGF7110-GZGF7110-LZ

Hanger kit EFi50/120/150 EA7090K EFi50xx/120xx EFi150xx

EA7090KEA7090K

EFC50/120/150EFC50x/120x/ 150x

EA7090KEA7090K

Door bar EFi50/120/150 EA7080 EFi50xx/120xxEFi150xx

EA7080EA7080

EFC50/120/150EFC50x/120x/ 150x

EA7080EA7080

tilt bracket EFi50/120/150 EA9145 EFi50xx/120xxEFi150xx

EA9145 EFC50/120/150EFC50x/120x/ 150x

EA9145

Page 57: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 53

Certification Reference Chartlogo rePresents Marking / CertifiCation

ATEX- European Union Hazardous Location Certification by UL International Demko A/S notified by number 0539

II 2 G Ex d e IIB T6 Gb Demko 09 ATEX 0926969X

European Union EMC and Safety CE

Recognized Component Mark for Canada and the United States UL E305448

CSA Mark with other Standards as indicated by the mark below logo. Motor Cert. LR66789

CSA Certified for both Canadian and United States markets Motor Only 1743107

CSA Certified to the applicable US Standards for gas and other liquid petroleum products 1743107

CSA Certified to the applicable Canadian Standards for gas and other liquid petroleum products

1743107

International Electric Code - worldwide certification standards for electrical equipment used in hazardous locations.

IECEx UL 13.0062X

INMETRO Mark -Brazilian Hazardous Location Conformity

Ex d e IIB T6 Gb UL-Br 13.0593X

North American Hazardous Location Certification

UL Class 1 - Group D UL Class II - Group E,F,G

Motor Cert. E312535

Registed by UL to a specifed ISO or QS System. UL ISO 9001:2008

iP rating first Digit seConD Digit

IP55 Limited protection against dust ingress. (no harmful deposit)

Protected against low pressure water jets from any direction. Limited ingress permitted.

IP65 Totally protected against dust ingress.Protected against low pressure water jets from any direction. Limited ingress permitted.

Page 58: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

54 www.euramcosafety.com

Notes

Page 59: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

www.euramcosafety.com 55

Page 60: PRODUCT CATALOG2015 - Fremtac · 2015. 6. 20. · fresh air for the whole work shift. Ideal for construction job sites to eliminate noisy gasoline-engine blowers. High-low control

Distributed by:

www.euramcosafety.com © 2015 Euramco Safety • June 2015

USAEuramco Safety2746 Via Orange WaySpring Valley, CA 91978 USA Toll Free: (800) 472-6326Phone: +1 (619) 670-9590Fax: +1 (619) [email protected]

CHINAEuramco Safety ChinaA11, No. 1 Jinxi RoadQingshuipu, Zhenhai Ningbo, China 315221Phone: +86-574-87979390Fax: [email protected]

LUXEMBOURGEuramco Safety SARL68, Avenue de la libérté1931 LuxembourgLuxembourgPhone: +352-26008055Fax: [email protected]

MIDDLE EAST – UAEEuramco Safety DubaiJebel Ali FTZPhone: +1 (619) 670-9590 x114Fax: +1 (619) [email protected]

Euramco Warehouses: