6
www.mage-roof.com MAGE ® SNOW STOP SOLUTIONS FOR ALL ROOFINGS AND REGIONS

Transcript of PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax...

Page 1: PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax or e-mail. +49/ 3535/ 4007-23 | schneelast@mage-roof.com

www.mage-roof.com www.mage-roof.com

MAGE® Roof & Building Components GmbHAn den Steinenden 7 | 04916 Herzberg | GermanyPhone +49/ 3535/ 4007-0 | Fax +49/ 3535/ [email protected] | www.mage-roof.com

INNOVATIVEPRODUCER

PARTNER OFROOFERS

ANDINDUSTRY

LOGISTICCOMPETENCY

SUSTAINABLEQUALITY DUE TO

INDUSTRIAL PRODUCTION

MAGE® SNOW STOPSOLUTIONS FOR ALL ROOFINGS AND REGIONS

SNOW LOAD CALCULATION

You can downlaod this form under www.mage-roof.com.Just complete the form und send via fax or e-mail.

+49/ 3535/ 4007-23 | [email protected]

MAGE Roof Building Components GmbHAn den Steinenden 7, 04916 Herzberg, Germany

Country / Snow load zone* DEHeight (above sea level)* metersRoof type (e.g. pitched roof, mono-pitch roof)*Roof pitch* degreeLength of rafter (Length from ridge to snow stop construction)* metersorHalf width of building floor plan metersLength of eaves metersPartial safety factor (yes/no)*

Type of roof covering (e.g. clay, plain or slate tiles)*Snow stop type (e.g. grate, pipe)*Type of fastening (e.g. roof batten, rafter)*Material (e.g. steel)*Coverage width* millimetersNumber of lines*

Name/Company*StreetZip Code / CityPhoneE-Mail*

Name of object*StreetZip Code / City*Land*Tile manufacturer/ type*

Form: Snow load calculation

Information about object

To calculate the appropriate snow stop system we need the values of snow load at the location of the building. For the highest possible stability of the snow stop system an exact indication of the requested data is required.Please e-mail or fax this form to us to the contact given below.

Information about planner/ executing company

* Mandatory fields for calculation and product recommendation

Phone +49 (0) 35 35 / 40 07- 0Fax +49 (0) 35 35 / 40 07- 17

[email protected]

Please have a look at our additional catalogues!

Page 2: PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax or e-mail. +49/ 3535/ 4007-23 | schneelast@mage-roof.com

www.mage-roof.com

LOG SUPPORT

LOG BRACKET

SNOW STOP PIPE UNIT FOR CLAY AND CONCRETE ROOFING TILES

SNOW STOP PIPE UNIT FOR STANDING SEAM ROOFS

to nail on or hook in the rafter

made of galvanised steel (for log woods up to 140 mm diameter)

with galvanised steel supports and aluminium pipes and connectors

SOLUTIONS FOR ALL ROOFINGS AND REGIONS

SNOW NOSES

for clay and concrete roofing tilesmaterial thickness: 1,2 mm, height: 66 mm, width: 34 mm

Article No. For tiles packaging 37833603**00 BogenFlatRoofPantile 100pcs. Meindl MZ3 JungmeierFlatRoofPantile Lafarge–RuppRubin13,11V JacobiJ12,J13 PfleidererTerraViva,Harmonica,Z4N Müller E32 Röben Fläming 37833604**00 BogenRupp-Granat 100pcs. NelskampD1337833610**00 JMS L15 (1987) 100 pcs. Koramic Wiekor L15 Mühlacker Z15 37833611**00 Creaton Futura 100 pcs. NelskampNibraF737833608**00 ErgoldsbacherE58,E58MAX,Florento 100pcs.37833607**00 Creaton Harmonie 100 pcs. Lafarge–RuppZ12 PfleidererTerraExtra37833606**00 BogenInterlockingPantile,Innovo12 100pcs. CreatonKerapfanne Jungmeier Karthago Lafarge–RuppRubin9V37833601**00 allconcreteroofingtiles 100pcs. Ergoldsbacher Linea37833602**00 allconcreteroofingtiles-bigsize 100pcs.

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black,VZ=galvanised

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black,VZ=galvanised

** pleaseaddcolourabbreviationwhenordering: RO=tilered,SW=black,VZ=galvanised

37822316**00 tonail 4pcs.37822315**00 tohook 4pcs.

37822314**00 1pc.

37845801**00 2.000 mm 1 unit

with galvanised steel clamp mountings and double pipe supports with aluminium pipes and connectors

37845701VZ00 2.000mm 1unit

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown,SW=black

HIGHEST QUALITY SPECIAL COLOURS UPON REQUEST

SNOW STOP UNITS

made of galvanised steel

FOR DIFFERENT LOAD STANDARDS AND ROOFINGS HIGHEST QUALITY SPECIAL COLOURS UPON REQUEST

1 tonail,forslatetiles** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black, OR=oxidered,VZ=galvanised 1onlyVZ=galvanisedandSG=slategrey

Unit consists of-1snowstopgrate-4snowstopsupports-2connectingelements

Snowstopgrateandsnowstopsupportalsoseparateavailable.

MAGE® SNOW STOP SYSTEMS

Today a snow stop system is essential due to the legal duty of the house owner to maintain safety and the frequently increasing extreme weather. To take account of this snow stop and snow retention systems are subject to a general static proof obligation in accordance to DIN EN 199-1-3 and the regulations of the ZVDH.

We offer system solutions that meet these requirements and are individually tailored to your needs. We take various factors into account e.g. roof pitch, rafter length, eaves length, type of roofing, snow load zone etc.

We assist you!

MAGE® SNOW STOP

Snowstopunits SnowstopplaintileLD-B

SnowstopslateLD-S

Snowstopuniver-salUni

SnowstopHDReinforced

ArticleNo. 37821630**00** 37821530**00* 37845601**00 37846002**00Roofcovering Claytile

ConcretetilePlaintileSlate

--+-

---+

+++-

++--

Dimensions Supportlength[mm]Grate length [mm]grate height [mm]

3203.000200

4003.000200

4853.000200

4903.000200

Feature Increasedloadcapacity - - + ++

Page 3: PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax or e-mail. +49/ 3535/ 4007-23 | schneelast@mage-roof.com

www.mage-roof.com

LOG SUPPORT

LOG BRACKET

SNOW STOP PIPE UNIT FOR CLAY AND CONCRETE ROOFING TILES

SNOW STOP PIPE UNIT FOR STANDING SEAM ROOFS

to nail on or hook in the rafter

made of galvanised steel (for log woods up to 140 mm diameter)

with galvanised steel supports and aluminium pipes and connectors

SOLUTIONS FOR ALL ROOFINGS AND REGIONS

SNOW NOSES

for clay and concrete roofing tilesmaterial thickness: 1,2 mm, height: 66 mm, width: 34 mm

Article No. For tiles packaging 37833603**00 BogenFlatRoofPantile 100pcs. Meindl MZ3 JungmeierFlatRoofPantile Lafarge–RuppRubin13,11V JacobiJ12,J13 PfleidererTerraViva,Harmonica,Z4N Müller E32 Röben Fläming 37833604**00 BogenRupp-Granat 100pcs. NelskampD1337833610**00 JMS L15 (1987) 100 pcs. Koramic Wiekor L15 Mühlacker Z15 37833611**00 Creaton Futura 100 pcs. NelskampNibraF737833608**00 ErgoldsbacherE58,E58MAX,Florento 100pcs.37833607**00 Creaton Harmonie 100 pcs. Lafarge–RuppZ12 PfleidererTerraExtra37833606**00 BogenInterlockingPantile,Innovo12 100pcs. CreatonKerapfanne Jungmeier Karthago Lafarge–RuppRubin9V37833601**00 allconcreteroofingtiles 100pcs. Ergoldsbacher Linea37833602**00 allconcreteroofingtiles-bigsize 100pcs.

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black,VZ=galvanised

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black,VZ=galvanised

** pleaseaddcolourabbreviationwhenordering: RO=tilered,SW=black,VZ=galvanised

37822316**00 tonail 4pcs.37822315**00 tohook 4pcs.

37822314**00 1pc.

37845801**00 2.000 mm 1 unit

with galvanised steel clamp mountings and double pipe supports with aluminium pipes and connectors

37845701VZ00 2.000mm 1unit

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown,SW=black

HIGHEST QUALITY SPECIAL COLOURS UPON REQUEST

SNOW STOP UNITS

made of galvanised steel

FOR DIFFERENT LOAD STANDARDS AND ROOFINGS HIGHEST QUALITY SPECIAL COLOURS UPON REQUEST

1 tonail,forslatetiles** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black, OR=oxidered,VZ=galvanised 1onlyVZ=galvanisedandSG=slategrey

Unit consists of-1snowstopgrate-4snowstopsupports-2connectingelements

Snowstopgrateandsnowstopsupportalsoseparateavailable.

MAGE® SNOW STOP SYSTEMS

Today a snow stop system is essential due to the legal duty of the house owner to maintain safety and the frequently increasing extreme weather. To take account of this snow stop and snow retention systems are subject to a general static proof obligation in accordance to DIN EN 199-1-3 and the regulations of the ZVDH.

We offer system solutions that meet these requirements and are individually tailored to your needs. We take various factors into account e.g. roof pitch, rafter length, eaves length, type of roofing, snow load zone etc.

We assist you!

MAGE® SNOW STOP

Snowstopunits SnowstopplaintileLD-B

SnowstopslateLD-S

Snowstopuniver-salUni

SnowstopHDReinforced

ArticleNo. 37821630**00** 37821530**00* 37845601**00 37846002**00Roofcovering Claytile

ConcretetilePlaintileSlate

--+-

---+

+++-

++--

Dimensions Supportlength[mm]Grate length [mm]grate height [mm]

3203.000200

4003.000200

4853.000200

4903.000200

Feature Increasedloadcapacity - - + ++

Page 4: PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax or e-mail. +49/ 3535/ 4007-23 | schneelast@mage-roof.com

www.mage-roof.com

LOG SUPPORT

LOG BRACKET

SNOW STOP PIPE UNIT FOR CLAY AND CONCRETE ROOFING TILES

SNOW STOP PIPE UNIT FOR STANDING SEAM ROOFS

to nail on or hook in the rafter

made of galvanised steel (for log woods up to 140 mm diameter)

with galvanised steel supports and aluminium pipes and connectors

SOLUTIONS FOR ALL ROOFINGS AND REGIONS

SNOW NOSES

for clay and concrete roofing tilesmaterial thickness: 1,2 mm, height: 66 mm, width: 34 mm

Article No. For tiles packaging 37833603**00 BogenFlatRoofPantile 100pcs. Meindl MZ3 JungmeierFlatRoofPantile Lafarge–RuppRubin13,11V JacobiJ12,J13 PfleidererTerraViva,Harmonica,Z4N Müller E32 Röben Fläming 37833604**00 BogenRupp-Granat 100pcs. NelskampD1337833610**00 JMS L15 (1987) 100 pcs. Koramic Wiekor L15 Mühlacker Z15 37833611**00 Creaton Futura 100 pcs. NelskampNibraF737833608**00 ErgoldsbacherE58,E58MAX,Florento 100pcs.37833607**00 Creaton Harmonie 100 pcs. Lafarge–RuppZ12 PfleidererTerraExtra37833606**00 BogenInterlockingPantile,Innovo12 100pcs. CreatonKerapfanne Jungmeier Karthago Lafarge–RuppRubin9V37833601**00 allconcreteroofingtiles 100pcs. Ergoldsbacher Linea37833602**00 allconcreteroofingtiles-bigsize 100pcs.

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black,VZ=galvanised

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black,VZ=galvanised

** pleaseaddcolourabbreviationwhenordering: RO=tilered,SW=black,VZ=galvanised

37822316**00 tonail 4pcs.37822315**00 tohook 4pcs.

37822314**00 1pc.

37845801**00 2.000 mm 1 unit

with galvanised steel clamp mountings and double pipe supports with aluminium pipes and connectors

37845701VZ00 2.000mm 1unit

** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown,SW=black

HIGHEST QUALITY SPECIAL COLOURS UPON REQUEST

SNOW STOP UNITS

made of galvanised steel

FOR DIFFERENT LOAD STANDARDS AND ROOFINGS HIGHEST QUALITY SPECIAL COLOURS UPON REQUEST

1 tonail,forslatetiles** pleaseaddcolourabbreviationwhenordering: RO=tilered,BR=brown, SW=black, OR=oxidered,VZ=galvanised 1onlyVZ=galvanisedandSG=slategrey

Unit consists of-1snowstopgrate-4snowstopsupports-2connectingelements

Snowstopgrateandsnowstopsupportalsoseparateavailable.

MAGE® SNOW STOP SYSTEMS

Today a snow stop system is essential due to the legal duty of the house owner to maintain safety and the frequently increasing extreme weather. To take account of this snow stop and snow retention systems are subject to a general static proof obligation in accordance to DIN EN 199-1-3 and the regulations of the ZVDH.

We offer system solutions that meet these requirements and are individually tailored to your needs. We take various factors into account e.g. roof pitch, rafter length, eaves length, type of roofing, snow load zone etc.

We assist you!

MAGE® SNOW STOP

Snowstopunits SnowstopplaintileLD-B

SnowstopslateLD-S

Snowstopuniver-salUni

SnowstopHDReinforced

ArticleNo. 37821630**00** 37821530**00* 37845601**00 37846002**00Roofcovering Claytile

ConcretetilePlaintileSlate

--+-

---+

+++-

++--

Dimensions Supportlength[mm]Grate length [mm]grate height [mm]

3203.000200

4003.000200

4853.000200

4903.000200

Feature Increasedloadcapacity - - + ++

Page 5: PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax or e-mail. +49/ 3535/ 4007-23 | schneelast@mage-roof.com

www.mage-roof.com www.mage-roof.com

MAGE® Roof & Building Components GmbHAn den Steinenden 7 | 04916 Herzberg | GermanyPhone +49/ 3535/ 4007-0 | Fax +49/ 3535/ [email protected] | www.mage-roof.com

INNOVATIVEPRODUCER

PARTNER OFROOFERS

ANDINDUSTRY

LOGISTICCOMPETENCY

SUSTAINABLEQUALITY DUE TO

INDUSTRIAL PRODUCTION

MAGE® SNOW STOPSOLUTIONS FOR ALL ROOFINGS AND REGIONS

SNOW LOAD CALCULATION

You can downlaod this form under www.mage-roof.com.Just complete the form und send via fax or e-mail.

+49/ 3535/ 4007-23 | [email protected]

MAGE Roof Building Components GmbHAn den Steinenden 7, 04916 Herzberg, Germany

Country / Snow load zone* DEHeight (above sea level)* metersRoof type (e.g. pitched roof, mono-pitch roof)*Roof pitch* degreeLength of rafter (Length from ridge to snow stop construction)* metersorHalf width of building floor plan metersLength of eaves metersPartial safety factor (yes/no)*

Type of roof covering (e.g. clay, plain or slate tiles)*Snow stop type (e.g. grate, pipe)*Type of fastening (e.g. roof batten, rafter)*Material (e.g. steel)*Coverage width* millimetersNumber of lines*

Name/Company*StreetZip Code / CityPhoneE-Mail*

Name of object*StreetZip Code / City*Land*Tile manufacturer/ type*

Form: Snow load calculation

Information about object

To calculate the appropriate snow stop system we need the values of snow load at the location of the building. For the highest possible stability of the snow stop system an exact indication of the requested data is required.Please e-mail or fax this form to us to the contact given below.

Information about planner/ executing company

* Mandatory fields for calculation and product recommendation

Phone +49 (0) 35 35 / 40 07- 0Fax +49 (0) 35 35 / 40 07- 17

[email protected]

Please have a look at our additional catalogues!

Page 6: PRODUCER - MAGE Roof · You can downlaod this form under . Just complete the form und send via fax or e-mail. +49/ 3535/ 4007-23 | schneelast@mage-roof.com

www.mage-roof.com www.mage-roof.com

MAGE® Roof & Building Components GmbHAn den Steinenden 7 | 04916 Herzberg | GermanyPhone +49/ 3535/ 4007-0 | Fax +49/ 3535/ [email protected] | www.mage-roof.com

INNOVATIVEPRODUCER

PARTNER OFROOFERS

ANDINDUSTRY

LOGISTICCOMPETENCY

SUSTAINABLEQUALITY DUE TO

INDUSTRIAL PRODUCTION

MAGE® SNOW STOPSOLUTIONS FOR ALL ROOFINGS AND REGIONS

SNOW LOAD CALCULATION

You can downlaod this form under www.mage-roof.com.Just complete the form und send via fax or e-mail.

+49/ 3535/ 4007-23 | [email protected]

MAGE Roof Building Components GmbHAn den Steinenden 7, 04916 Herzberg, Germany

Country / Snow load zone* DEHeight (above sea level)* metersRoof type (e.g. pitched roof, mono-pitch roof)*Roof pitch* degreeLength of rafter (Length from ridge to snow stop construction)* metersorHalf width of building floor plan metersLength of eaves metersPartial safety factor (yes/no)*

Type of roof covering (e.g. clay, plain or slate tiles)*Snow stop type (e.g. grate, pipe)*Type of fastening (e.g. roof batten, rafter)*Material (e.g. steel)*Coverage width* millimetersNumber of lines*

Name/Company*StreetZip Code / CityPhoneE-Mail*

Name of object*StreetZip Code / City*Land*Tile manufacturer/ type*

Form: Snow load calculation

Information about object

To calculate the appropriate snow stop system we need the values of snow load at the location of the building. For the highest possible stability of the snow stop system an exact indication of the requested data is required.Please e-mail or fax this form to us to the contact given below.

Information about planner/ executing company

* Mandatory fields for calculation and product recommendation

Phone +49 (0) 35 35 / 40 07- 0Fax +49 (0) 35 35 / 40 07- 17

[email protected]