Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

33
Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore

Transcript of Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Page 1: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Process Analyzer Sampling with Astute System

IFPAC 2008 – Baltimore January 29 ,2008

Page 2: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

EIF FILTRES

French compagny specialized since 30 years in

filtration equipments and sampling treatments.

January 30 ,2008January 30 ,2008IFPAC 2008 – Baltimore January 29 ,2008

Page 3: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Our philosophy:

Leave the contaminants in process

Separate as fast as possible the contaminants from the

sample

Reduce the treated volumes

Reduce and make easier the maintenance

January 30 ,2008IFPAC 2008 – Baltimore January 29 ,2008

Page 4: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Cross flow filtration with blow back systems

Liq/liq coalescing filter with jet fuel separator

Gas treament column

L Type housings

Modular and smart systems

For that, we have developed :

IFPAC 2008 – Baltimore January 29 ,2008

Page 5: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Realisations

IFPAC 2008 – Baltimore January 29 ,2008

Page 6: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Realisations

IFPAC 2008 – Baltimore January 29 ,2008

Page 7: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

COALESCING

FILTER

FILTER

GAS EJECTOR

SEPARATOR

VISCOSITY-DENSITY SENSOR

BLOW BACK

SYSTEM

EIF

TOPWORK COMPONENTS

ISA/ANSI S 76.00.02 Compliant

Page 8: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Petrochemical application

IFPAC 2008 – Baltimore January 29 ,2008

Page 9: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Typical gazoline sampling in front of Chromatograph

IFPAC 2008 – Baltimore January 29 ,2008

Page 10: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

IFPAC 2008 – Baltimore January 29 ,2008

Page 11: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Specifications :

Fluid : gazoline

Filtration needed

liquid-liquid coalescing needed

IFPAC 2008 – Baltimore January 29 ,2008

Page 12: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

New design in beginning of 2006

Cross flow filtration with blow back system

modular Intraflow assy

liquid-liquid coalescing with separator

Pneumatic control ( specific for the test)

IFPAC 2008 – Baltimore January 29 ,2008

Page 13: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Gazoline sampling for sulphur analyzer

IFPAC 2008 – Baltimore January 29 ,2008

Page 14: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

TM

Cross flow filtration

Blow back system DECLIF HP MINI(low dead volume)

To analyzer via Intra flow

Fast loop

Cross flow filter 2S2LIF GM MINI 2 microns(low dead volume)

IFPAC 2008 – Baltimore January 29 ,2008

Page 15: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

TM

Gazoline treatment

Séparator

Coalescing

housing

IFPAC 2008 – Baltimore January 29 ,2008

Page 16: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

first installations comments

Flow sheet needed

Free space needed around components with maintenance ( filters for example …)

How to install , vertically or horizontally

Drain and vent take into consideration

IFPAC 2008 – Baltimore January 29 ,2008

Page 17: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

The Answer !!

IFPAC 2008 – Baltimore January 29 ,2008

Page 18: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

3 D Solution

IFPAC 2008 – Baltimore January 29 ,2008

Page 19: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

The solution = 3D

Patent Application Pending

IFPAC 2008 – Baltimore January 29 ,2008

Page 20: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Video

Page 21: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

The same sampling evolution

IFPAC 2008 – Baltimore January 29 ,2008

Page 22: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

TM

Compact

Top equipment easily accessible

Low dead volume

Fast loop

Astute SCF with tangential element0,5 microns

IFPAC 2008 – Baltimore January 29 ,2008

Page 23: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

ASTUTE :

SP 76 compliant

Integrated cross flow filter

Modular

Compact

Low dead volume

Upgradeable

IFPAC 2008 – Baltimore January 29 ,2008

Page 24: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

IFPAC 2008 – Baltimore January 29 ,2008

Page 25: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

ASTUTE :

Top equipment easily accessible

Vertical and horizontal position installation possible

On the fast loop or in derivation

All the different paths on the same module( sample, standard, drain, vent ..)

IFPAC 2008 – Baltimore January 29 ,2008

Page 26: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

For the sampling:

Reduce or eliminate the sampling line

Decrease the response time

Reduce the product and drain volumes

Temperature control and heating easier

Reduce the sample contamination risk

IFPAC 2008 – Baltimore January 29 ,2008

Page 27: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

ASTUTE contribute to :

Measurement quality improvement

Cost of build and operating cost reduction Maintenance easier

Installations sécurity improvement

IFPAC 2008 – Baltimore January 29 ,2008

Page 28: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

APPLICATIONS

IFPAC 2008 – Baltimore January 29 ,2008

Page 29: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Moisture sensor

Pressure regulator filter

Flow meter

IFPAC 2008 – Baltimore January 29 ,2008

Page 30: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

TMTM

ISOLATING VALVES

PROCESS PIPE

DIRECT CONNECTION ON PROCESS

CCIMS CLAMPS

CCIMS System

IFPAC 2008 – Baltimore January 29 ,2008

Page 31: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Direct connection on process

Very short response time

Easy maintenance clamp connection

Low contamination level

Sampling reduction cost

No drain

IFPAC 2008 – Baltimore January 29 ,2008

Page 32: Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29,2008.

Thank you for your attention !

And welcome to our Booth 402

IFPAC 2008 – Baltimore January 29 ,2008