Procedure Review
Transcript of Procedure Review
a
ENGINEERING DATA TRANSMITTAL%. 1ofL__
‘EDT 622476
2. To: (ReceivingOrganization) 3. From: (OriginatingOrganization)
Distribution Data Management/TechnicalBasis and Planning
5. Proj./Prog.lOept./Div.: 6. Design Authorityl Design Agent/Cog.Engr.:
Year 2000 TWRS Maintenance M. R. AdamsProcedure ReviewReport/WasteManagement/TBP/Process ‘Engineering8. Originator Remarks:
This,document is being released into the supporting documentsystem for retrievabi1ity purposes.
11.Receiver Remarks: 11A. Design BaseLine Oocument? [] Yes [x] No
For release.
15. OATA TRANSMITTEO
(A) (c) (D]Item (B)Doc.ment/DrawiwNo. Sheet Rev. (E]T#tleorDescriptionofData
No. No. No. Transmitted
.1 HNF-341O N/A o Year 2000 TWRSMaintenance ProcedureReview Report
4. ReLated EOT No.:
N/A
7. Purchase Order No.:
NIA
9. Equip.lcomp-anentNo.:
10. System/Stdg./Faci(ity:
N/A12. Major Assm. Dwg. No.:
N/A13. Permit/PermitApplicationNo.:
N/A14. Re.quirsd Resp3nse Date:
09/21/98
T
(F) G) (H) (1)
APPr..al Reason Origi- Rece,v.Dedg- for nator ernator Tran$- Dispo. C@..
mittal sition sidon
N/A 2 1 1
16, KEY
Amxo.d Desi9.ator(F1 ReasonforTmnsm,ttal(G) OiSPOSidon(H)& (1)
E,S,0,D orN/A 1,APProval 4,Review 1.AmIroved
(seeWHC-CM-3-5,
4.Reviewed“o/comment2.Release 5.Post.Review 2.Amxo”edvdcornrnent
Sec.12.715,Reviewedwbamment
3.Information6.DIst,(ReceiptAckmmv,Required) 3.Oisappmvedwlcomment 6.Receiptacknowledged
17.SIGNATUREIDISTRIBUTION(SeeAporovalDesignatorforrequiredsignatures)
(G) (H)(J)Name
(H)Rea- Disp. (K]s@ature (L)Date (M)MSIN D@. (J)Name (K)3ignat”re(L)Date (M)MSIN
son
Design Authority 1
Design Agent
2 I Cog.Eng. M.R. Adam?.IW% 7/z,/qgl
2 { Cog. Mgr. J.U. Nunt
QA/
Safety1
Env.
18. 19. 20. 21. DOE APPROVAL (if required)
A.E.Ctrl. No.
N/A [1 Approved‘ [1 Approved wlccmnents
AuthorizedRepresentativeDate
1
[1 DisapprovedwlconmentsforReceivingOrganization CogntzantMamger
SD-7400-172-2 (05/96) GEF097
BD-74LX?-;72.1
Year 2000 TWRSReport
Maintenance
HNF-341O, Rev. O
Procedure Review
M. R. AdamsLockheed Martin Hanford, Corp., Richland, WA 99352U.S. Department of Energy Contract DE-ACO6-87RL1O93O
EDT/ECN: EDT-622476 UC: 2070Org Code:B&R Code:
Key Words:Procedure,
Abstract:
7A11O Charge Code: DIY1lEW 3120074 Total Pages: 4/
Year 2000, Y2K, Tank Waste Remediation System, TWRS,Review, Report
N/A
TRADEMARK D1SCLAIMER. Referenceherein to any specificcomnercia~ product,process, or service bytrade nsme, trademark,manufacturer,or otheruise, does nor necessarity constituteor imply itsendorsement,recomnendation, or favoringby the United States Governmentor any agency thereof orits centractors or subcontractors.
Printed in the United States of America. To obtain copies of this document, contact: UHC/BCSDocmnent Contro[ Services,P.O. Box 1970, Mai[stop H6-08, Richland UA 99352, Phone (509) 372-2420;Fax (509) 376-4989.
-x&J?ti.+/7 9/z//7g
R&(eas& ApprovaI Date
Approved for Public Release
A-64D0-073 (10/95) GEF321
HNF-341O, Rev.
Y2K TWRS MAINTENANCE PROCEDURE REVIEW
o
A cmrcem existsthatacme equipment iew might containrnicroprom.saorathatam dependent upon a time
datefonctien.The majorityofthe softwareprogramming formicrepmcessom has onlyutilizeda 2 digit
identifierfortheyear. With tieapproach oftheyear 2000, (Y2K), them isconcernthatthe datefnrmtion
wilfnot be.correctlyrecognizedand some fnrm!ionawillnot operateproperly.TWRS maintenance
pmeedurw have besn reviewed te iddfy equipment corrfmnentathatmay not be Y2K cempliant
E@H@gjUdg~@ Wm u!ifizdto ehimite prmedurcs mrd equipment thatiaobviouslynot impacted
by Y2K, (ex W22036, Impection of rwerhead doer$ W22019, Inap@ion and testof GFCI receptacle,
etc.)
The TWRS Maintenance Froeedureindex was utilizedaa a basisforreviewingtheprocedures Initially,
theindexwas reviewed and Pecedurw dealingwith equipment thatwas obviouslycompliautwere
identified.From thatpoi@ theproceduresforausp+xteqrdpmrnt were.reviewed to determineiftherewas
anything$ theprmdure toindicateexistenceofa tie-date dependent iimctiom Additionally,a
COIIIPU- WIJ~ =ch Ofthem p~= was COmfuctedto identi pmceduma containingthefollowingkey words
TWRS Maintenance Procedure Search Y2KKey Words
Cleek LDK Prrreeasor
Computer ENR4F Timer
PLC Prugranrmable Mire. proressor
Pcu-1 TMcs ContioUex
PIogmmrrrableLogic Medicon PAL-AT
A number ofthepmwdurm appeared aa multiple“hits”on severalofthe aemch lists.Afthorrgbidcrrdfied
inthe search,etlenthekeyword was ordyused toident@ aaaeciatedequipment er furretionaand the
eqrripmemtitaelfianot impacted by Y2K concerns.hr othercaaea,thekey word isused to describea purely
mechanical funcdon thatisnot impacted by Y2K (ex.Cleck or tirmwreferringtoa mechanical clockor
timer).Rcsrrftaofthe searchhave been mmmmizd aa attached.
Following searchoftheprocedures,theJCS was searcheduairrgprecedurenmnbcr toatterupttofurther
determineiftheequipment in qrrestienwas Y2K compliant.Frem theJCS ayateq referenceinformation
such aa CVf fileand drawing numbers were obtainedtopermitadditiormfreseamh intotheequipment or
components.
Comments relatedtopmcedrrresforpotentiallysuspectequipment havo been identifieden theProeedrrre
Index, Additionalresearchwillbe performed todeterminecompliance oftheeomfxurent
0
Co
HHt-3411J,WI. [Jsl,..,1
I I ! I I II- Ic-nti
)37,1-0 I.4 m 1. Imm., Tim.,,1.,.,
Commteu [w camnent tuner:
\61n61f4040-a I Btlwlfo
wr61f4060.o Bm61fo.r ,- ,. ,
W408.1 ‘p
,,!.,.! ISl,.””..w.
kitfviwo-‘ - , -—. ..... I
w!6tf413.0-0 V3tfwf2,.
!61fwtf423.o-o
KtfY5if424“ ‘
Y3tfWf2t3!-*4 e-l
,,,.,-3 I,rner.ruy,,~,~
3.o-a
●.U-” ,...,,!“,,!.2.k.o Imer on~
4.14,,.. 1 1 .,..”1,.
d,...4
man, -vans I)p.. I
- ,,---.--,,.,..-lUddt21dd293.a-O
,terf,m= tih P(Y1.4 I
PAL-AT mdl80khastimeldatedkplayCV122798
Page2
HNF-.34IU,KL!V.US,I.A1
1- comnenv 1Processocknisc’+3mi5c3S4.ao lx I 15filesidentified
kwdt3rdt22.bO lx Irlllscwllisczs.1.a-l ~
UcdX5tcd312.1
ud.5tCd322.au lx I Ivall!ollsuI.W
!6wifOlo.1-a
W
strainslgnatprw VIUW IML-.
I I–.
,W lx
‘Bcdtey CheckforPLC
I I I I,,——”. . . ‘-’--’---’- “-’ --–-s iliter
lDICON PLC’SInImp
f’61Ml1Z-b
“- “---’‘-- ‘“--” ‘“_)DIcoN PLC’S
I I lm.?Jx..o.oiilstolywt01tSts
MOOICON PLC% InlcOp
L61fW052.O.b I I Ipnicrowocessa
!6ifWfl%tr.a-O
wfwlfl%lv.f’‘ 1 MODICON PLC%
151P&tt1361w...wf16if247.
MODICON ‘“-’-
,+,..,. 1 1 1,:ILn I!,
ICON PLCS k
m: I Im
;Inlwp
VLL s InImp
‘.bo I I I I I-. ,-----
5 Identitid---- ....... .. ---- . . ,
5inloop. .
)]
Jinloop
VLG s InImp
IImp
MODICON PLC’SInImp
ICON PLC’SInbop
“--. PLC’slnImp
ICON PLC’SinIbop
“--. PLC’slnIkmp
ICON PLC’SinImp
“--. PLCsln Imp
ICON PLC’SInImp
“--. PLC’SInlc.ap
~ I I I I I..- . ------
wfkd
~ --------. . ,‘IcON PLc’s in Iwp.--. ----
p
4 PLC<SinImp
i PLc’sinlc.ap
-Blesldentifi
w244.w ~MUUltiUN
w371 ,W
T mdl&lk-hastlmtidatefunction lwlt-wf379.cm ~MUUltiUN FLU’SIn1~
PLtiSIn(@3p
MODICON PLC’SinIwp
ww+iu,w I I)DICON PLC’SinImp
)DICON PLC’Sinloop
MODICON PLC’SinkOp
J. I I
W400.O-D MODICON PLC’SInlca~ pMOOICON PLC”Sin100
PMODICON PLC’Sinloop I
I
Page3
5
HNI-341U, I/@V.USh.dl
proaramnable; c-nt ,MoD1co~ Y?L!52 s-n~
5tl’6U401 .0.0 MODICON PLC’S [n bop !W6tf423.M MO DICON PLC’S in Imp
W4C6.W MODICON PLC’S In loop W424.&b MODICON PLC’S In 130P
W413.O-D MODICON PLC’S in Imp wl-v5tf4s4.la No clcck-bti tied to MODICON PLC
wfMtf423.w MODICON PLC’S in Imp
‘6tfU3tf424SLb MOOICON PLC’S In Imp
k5ir6if44s00 x Check VI Prob?ibiy NO fimddate
knisc\7mlsc23S,a4 - ENRAF OensRometer - erasable EPROM 77
6
Page 4
I
Illlrlll!llt 111111111111 1111111111
.+Olrlooooooooo 0000 OL!IFIOOOOO Ooo1.-1ooooooON N* WMO=JOFINCOUI W1-WUIO NLO~O-l IOUlh WON ONMONOOOOOOFIANNC4NN r4ac4Nmmmme**e* loulwPP1-mm111111111!11 1111 !1111111 Illlllltll000000000000 000000000000 0000000000EIE!HE4E+EIEIE4UBHUUBU Ui+UUBt+UhUhEIBBHB BBUB
1111 I 11111111 !111 11111111
0
r.
Maintenance Procedures
Procedure Type
1 - Loop Calibration 5 - Preventive Maintenance
2 - Maintenance (Troubleshoot and or Repair) 6 - Calibration
3 - Functional Test 7 - General (Doesn’t fit anything else)
4 - Predictive Maintenance
-...—-. .. .... ....... --.--...---BCLIE = SYS’J.’IJVCUMLKJNMN’l lJLiSlbNKIUK
BCDE sYSTEM/COMPONENT DESIGNATOR SYSTEM/COMPONENT DESIGNATOR SYSTBM/COMPONENT DESIGNATOR
lss Asbestos Ventilation Tank Annulus
kNN Annunciator Installed Vision Systems Ventilation Tank Primary
BA Breathing Air Level Control Indicating Devices Waste Storage Tank
CATH Cathodic Protection Leak Detectors and LDE devices Waste Storage Tank Annulus
ass Computer Automated Liquid Observation Vans Waste Transfer
Surveillance System
CN Cooling Water MISC Miscellaneous[
CVT Converter/Transmitter PCD Pressure Control/Indicating Devices
EBA Emergency Breathing Air REcD Recorder or associated devicesI
EDS Electrical Distribution RM Radiation Monitoring
EGEN Generators Electrical SA Service Air1
EMER Emergency System SALW Saltwell Equipment
FACE Facility/Shop Equipment SHM Standard Hydrogen MonitoringI
FCD Flow Controller/Indicator TcD Temperature Control/Indicating
Device Devices
GENI General Instrument TMAC Tank. Monitoring & Control System1
GC Gas Characterization VAC Vacuum System
GLY Glycol Cooling Vs Vent and BalanceI
u . ..-GM I GasMonitoring ]VT I ventxLatlOn system 1 I
HNF-341O, Rev. O
8
-==========> .-.----- ...... —.—.—.—...... ——-.—.—.+7/27/9.9 Master Index G :~ve and Developing Rag. 1
Tank Farm Uperatinq .,,ciMaintenance Procedures
PRCCEDIEW NUMSER WV RF.V#PRCCEDURK TITLE RELEASE DATE STATUS--- -------------------------------------------------------------------------- _________ ----------
1-GENI-404 B 0
1-LDD-061 B 0
2-LcD-035 G 0
t*m&Mw*w#iiw2%wR
2-NA2-040
2-MIsC-001
2-MIsC-013
2-MIsc-014
2-MISC-049
2-MIsc-288
2-vT-262
2-wT-216
2E18021
2E22003
2E22020
2E22025
2E22039
2E22050
2E22091
2E22096
2E23032
2E24009
2E24022
2E88004
B
B
c
B
c
B
A
A
1
3
2
2
4
4
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
E
0
F
A
0
B
c
B
A
c
0
INDEPENDENT SPEEDIANPS MONITORS 101-SY LcOP CAL1BSATION CHECKS 7/15/98 ACTIVE
CAL1BPATION OF HORIZONTAL LATESAL MONITORING SYSTEM REVISING
TRoUBLESHCOTING AND iY2PA1ROF FCX3D1NSTRUM2NT CORPORJ+TION LIQUID LEVEL GAU SEVISING
SET-UP CONTINUOUS LEAK DETECTION SYSTEM FOR CROSS-SITE TSANSFERSO 3/06/98 AcTIVEp*:&wwi$l$Aw
.. ......~w~~.c%=+wxm:m-w
TROUBLESHmT AND’’tiPtiR‘lNNDNCIATOR PANELS IN THE TANK FM FAcILITIEs, 20 RSV1SING
HANDLING AND HCOKUP OF TANK FARNS PUNPS ASV1SING
MAINTENRNCE OF SPARLING METER, SPARLING 37770, HIGH TENSILE X-290 REV1sING
TANK FASN RUN-IN TEST FOR SUBMSRSIBLE AND FLYGT PUNPS REVISING
BOLT TORQUING GUIDELINES REVISING
PONDS/DITCHES/SLIDE GATES SEVISING
SEPL?+C=NT OF CONSUMABLE CCNPONENTS FOR BELT DRIVEN FANS AT EAST ARBA TAN DEVXLOPING
DISA.9SEl@LYAND SEA.SS2?@LYOF SOLENOID OPESATED VALVES IN THE D1VERS1ON BO 4/03/98 ACTIVI
241,-ATY?+ ,~GLE TIMER SE+? FUNCTIONAL TEST 12/11/90 ACTIVE
Www=+w-lwww. . ..... .~-%=.wm%mx~e%w%xw,-~-a%%1NSPECTION OF WRGENCY LIGHTS FOR EAST TANK FARNS ACTIVE
PEEVTNTIVE MAINTENANcEIAUJUSTMENTS FOR CASS MODENS AND AMPLIFIER IN 200 AS 4/16/91 ACTIVEw~~gmw~-wfiw~+;-%-wy~mpGROUND FAULT CIRCUIT lNTEEFUJPTERS EIJNCTIONALTEST PRCCEDUS.2 AcTIVE
2750-E CASS PCWSP.SLOCPOWER COND1TION1NG SYSTEM
FUNCTIONAL TEST OF CA= ALRSMS FOR POWER CONDITIONING SYSTEN 2750-E BUILD1
OPESATING LOAD CHECK RND THESMRL HEATING SURVEY OF THE 204-Rs D1sTR1BUTION
OPESATING LOAD CHECK AND THESMAL SURVEY OF THE 241-A,AX,AY,A2 D1STR1BUTION
SEMI-ANNUAL AIR CCMPiVSSSOR 1NSPECTION 204-Rs (#1)
CONDUCT v1&JAL EXTERNAL 1NsPEcTIoN OF SODIUN HYDRoXIDE (N,oHI TANK TRUCK 6
PODS/D1TCS2S/SLIDE GATES
LORD TEST 272-AW MONORAIL HOIST (EH-011
HNF-341O, Rev. O
2/19/98
11/16/95
12/23/91
2/19/98
5/22/97
8/11/92
9/30/91
7/13/09
ACT1V2
ACTIVE
ACTIVE
ACT1V2
ACT1V7?
ACTIVE
ACTIVE
ACT1V2
9
====—.-__._..=-. =.==..==.=.=.=.===.==.=====.=.=.========.========.==------ ..=.=.====================================.============-------- -==========--—.--—. -----7/27190
-------
Master Index of Active and Developing Page 2Tank Farm Operating and M.intena!we Procedures
PRCCEDUXE NVf+BER FC3V XEV# PRCCEDURE TITLE RELEASE DATE STATUS
2W22001 3
2W22014 4
2W22019 2
2W22022 3
2W22036 2
2W22047 0
2W23007 1
2W23008 2
2W24011 0
2W24016 0
2W24018 0
2W24019 0
2!424022 0
2W24023 0
2w24024 0
2w24025 0
2w24026 0
2w35004 o
3-EDS-081 D
E
A
B
E
B
B
0
0
0
0
0
0
D
0
0
0
0
A
0
-------------------------------------------------------------------- ---._- ---------PREVENTIVE MAINTENANCE ACOUSTIC PROBE FOR DRY WELL VANS
----------6/29/90 ACTIVE
w-w.%m;=-=$~wa~x=weax~l, ~7,951NsPECTION OF DRY WELL VAN PROBE CONNECTIONS AND BOCW PENDANT EWITCH ACTIVE-H?3$mmimz=@.%kw+m%xBw.~*xH=%?~~m~aDRY WELL VAN CCNPUTER BATTERY BACKUP F$JNCTION+ TEST ACTIVE
mKm@&mxM.~ .-x-F.*xaL~=~!- 4,24,96NINUAL TF.MPESATUFW R2i%1NGS FOR WEST AEEA TANK FARMS ACTIVE
1NSPECTION AND CLEANING OF THE PCS MICRO CCMPUTER (MICRO PAC 80/A) 11/25/92 ACT1V2
m%~-~t$w.~.k~ :‘:Mw&%m.w~?~wi$zVyp%Yz$%$w.wsxAF&Y2F%w<w%m1NSPECTION AND TESTING OF AUXILIARY GENERATOR OUTPUT ON DRYWELL VANS
PORTRRLE TCOLS AT 272-WA MAINTENRWCE
1NsPEcTION AND TEST OF GFC1 RECEPTACLES
PREVENT1V2 MAINTENANCE AND 3UNCTIONAL TEST OF 1000 CEN PORTABLE EXHAUSTER
1NsPECTION OF OVERHEAE LKx7RS
200 WEST TANK FARNS DE-W1NTER1ZATION
PRW7ENT1VE NAINTENJ!NCE OF LEAK DETECTOR CAISSON BLOWERS AND HOISTING NE&A
PEDESTAL AND BENCH GRINDER 1NSPECTION - WEST NAINTENRNCE SHOPS
ACT1VATION ON “WINTERIZATION-S200 WEST TPNK FRRNS AND FACILITIES
INSPECT AIR COND1TIONERS FOR DIGITAL ANALCG CONTROL SYSTF.N IDACS 1 TRAILER
ANNUAL MAINTENANCE FOR 241-sX-701 SAHARA EP-10 REGENEWTIVE AIR DRYER
MONTHLY MAINTENANCE FOR 241-SX-701 SAHARA EP-70 REGENEEATIVE AIR DRYER
ANNUAL NAINTENRNCE FOR 241-U-701 HANKISON DH-45 EEGENERATIUE AIR DRYER
MONTHLY NAINTENANCE FOR 241-U-701 HANKISON DH-45 REGENEXATIVE AIR DRYER
ANNUAL NRINTENANCE FOR 242-S SAHARA EP-140 REGENERATIVE AIR DRYER
MONTHLY NAINTENANCE FOR 242-S SAHARA EP-140 REGENEXATIVE AIR DRYER
ANNUAL NRINTENANCE FOR 241-T-601 TRINITY REGENERAT1V71AIR DRYER
INSPECT 272-wA MoNoRAIL HOIST (WH-03) WIRE ROPE
1NSPECTION AND TEST OF GFC1 RECEPTACLES
HNF-341O, Rev. O
10
5/02/95
1/15/98
2/23/98
2/23/98
5/30/97
6/16/89
6/29/90
10/14/92
8/03/93
1/23/94
1/23/94
1/23/94
1/23/94
7/23/94
1/23/94
1/23/94
1/05/93
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIUE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcTIVE
ACTIVE
AcTIVE
ACTIVE
ACTIVE
ACT 1V3
ACTIVE
REVISING
-————-__-.=. .- ——-————————————-— _________________________________________ ________=___________________.------------ --------- .-———————-————7/27/98 M.Ste. Index Of Active and Dw,hoPing
Tank Farm operating and Maintenance ProceduresPage 3
-_--_---_—_-_-_-_—--------
PRIXEDVRE WER REV BEV# PRDCEDUIW TITLE RELEA3E DATE STATUS________________ --- --- -------------------------------------------------------------------------- ---------3-EDs-180 B 0
3-ENER-316 B 0
3-EMER-317 B 0
3-LDD-053 A 0
3-LDD-055 A o
3-LDD-058 D o
3-MISC-126 A o
**:~L$~#~:f~.@&yw;w:***A *,*
3-MIsc-279 A o
m@&9BxKa$@%$.w.?m
3-MIsc-289 0 0
Mw#Mx*$xw&Aw)wwf;k%
mRKiwwxwMw*ww
3-MIsc-296 A 0
3-MISC-363 A o
3-RN-321 A 0
3-sJI-504 B 0
3-V3-157A B 0
3-VB-157AX B 0
3-vB-157B B o
3-VB-157BX B 0
3-VB-157BY B 0
3-VB-157C B 0
GROUND FAULT CURRENT lNTEBRUPTERS SUNCTIO?NL TEST PRCCEDUR3 REVISING
1NSPECTION OF EMERGENCY LIGHTS FOR EAST TANK FARMS REVISING
1NSPECTION OF 21.2ZRGENCYLIGHTS FOR WEST TANK FARMS 5/21/98 ACTIVE
INTRINSICALLY SASE LEAK DETECTOR BELAY BENCH TEST DEVKLOPING
TROUBLESHCOTING AND mPAIR OF LIQulD DETEcToR ILEAX DETECTOR EL3N3NT AND L REVISING
VERIFICATION OF FCOD INSTRUMENT CORPORATION LIQUID Lw3L muGE R3F3RENCE E REVISING
EAST TANK FRRMS WEEKLY CHECK OF HEATER AND HEAT TRACE 1/09/98 ACTIVE
FUNCTIONAL CHECK OF R3PLP.CEMZNT CST SYSTEN IW-05Sj TRANSFER pUMP SXUTMXJN
-.w@#mB$&%%*s.w==m%t2m+~-.%*x-&~*&gp;#w&m*:mw&mFUNCTIONAL TEST OF REPLRCENENT CROSS-SITE TEANSFER SYSTF.!4BDCSTER PUMP sxu
M.w.m%%@E-H*mJw. .. .. -,
FUNC!TIONALCHECK OF THE PAL-AT BACKUP BATTERY 4/03/98 ACTIVEmN%%.m8$m”#&:m%wm$PmB<@-ti%~Mm_~~Em$8:@;%wmr@
.,-....-+%/w .
E’ONCTIDNALCHECK OF RXPLACEMENT CROSS SITE TRANSFER SYSTFM (w-058) FLUSH S
IUNCTIONAL CHECK OF SO- lljTERL~KS FO:RTHE SHUT20NN OF TRANSFER PUMP 3/07/9B~~~
ACTIVE.,,..;@~&.m@@~md@@@#T$yy9pm@$~m
,~CT1ONAL CHECK OF CROS<%lT; ‘TF&&R LINE LEAK DETkdT1&N CCMPUTER GENER
~28~#Bm=4#im?8w&&5K$Rx#%x*w&@wm?m~mxwwmcT1ONAL CHECK OF F.EPLACPMENT CROSS SITE TEANS3’ERSYSTEM BOOSTER PUMP SH DEVELOPING
WINTERIZATION/DE-WINTERI ZP.TIONEAST TRNK FARMS 10/18/97 ACTIVE
CALIBRATE NCR MODEL ADM-61OA RAD1ATION INDIcAToR WITH MODEL GP-1OOC RADIAT 8/09/ 98 ACTIVE
Eberline .R,adiationMonitor Functional Checkw%w~
9/11/97 ACTIVE,~W~Ayq~m~W~:&y&:mEw,wMm
WHITTAKER XYDR&EN CELL FUNCT1ONAi ‘?ES+ 2/24/90E~~E~E@m*&%~iwww
AcTIVE
APPENDIX A 241-A TANK FARM BREATHER FILTER AEROSOL TEST DATA SHEETS KEVISING
APPENDIX AX, AX TRNK FAKM BREATHER FILTER AEROSOL TEST DATA SHEETS KEVISING
APPENDIX B, 241-B TANK FAKN BREATHER AEROSOL TEST DATA SHEETS EF.VISING
APPENDIX BX, 241-BX TANK FARM BE3.ATHER FILTER AEROSOL TEST DATA SHEETS REVISING
APPENDIX BY, 241-BY TANK FARM BF.EATHER PILTER REROSOL TEsT DATA SHEETS R3V1SING
APPENDIX C, 241-C TANK FAFJ4BKEATHER FILTER AEROSOL TEST UATA SHEETS REV1SING
HNF-341O, Rev. O
11
--------7/27/98 Master Index of Active and Developing Page 4
Tank Farm operating and Maintenance Procedures----------- ______ -------- ----
PROCEDURE NIJlmER EEV REV# PRCCEDUFW TITLE--._-____--__-_- --- --- --------------------------------------------------------------------------
3-VB-157DU B 0 APPENDIX DU, 244-U DCRT BEE&THER FILTER AEROSOL TEST DATA SHEETS
3-VB-157EW
3-VB-157QB
3-vB-157Qc
3-vE-151QT
3-VB-157S
3-VB-157SS
3-VB-157SX
3-VB-157T
3-VB-157TX
3-VB-157TY
3-VB-157U
3-VB-157VA
3-VB-157W
3-VB-157W
3-vBP-151
5-3A-124
5-CATH-221
5-EDs-044
5-EDs-050
5-EDs-146
5-EDs-278
5-EDs-341
5-EDs-342
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
c
B
D
A
A
B
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
AppENDIX EW, 241-Ew-151 TANK BREATHER FILTER AEROSOL TEST DATA SHEETS
APPENDIX QB, 241-BX-101 BREATHER F1LTER AEROSOL TEST DATA SHEETS
APPENDIX CC, 24I-c-103 BREATHER FILTER AEROSOL TEST DATA SHEETS
APPENDIX QT, 241-TX-113 BREATHER FILTER AER6SOL TEST DATA SHEETS
APPENDIX S, 241-s TANK FARM BREATHER AEROSOL TEST DATA SHEETS
APPENDIX ss, 241-s-304 CATCH TANK BFViP.THERFILTER XROSOL TEST DATA SHEETS
APPENDIX SX, 241-SX TANK FARM BREATHER AEROSOL TEST DATA SHEETS
APPENDIX T, 241-T TANK FARM BREATHER AEROSOL TEST DATA SHEETS
APPENDIX TX, 241-TX TANK FARM BREATHER AEROSOL TEST DATA SHEETS
APPENDIX TY, 241-TY TANK FARM BREATHER AEROSOL TEST DATA SHEETS
APPENDIX U, 241-U TANK PARM BREATHER AERosoL TEST DATA SHEETS
APPENDIX VA, 6241-A CROSS SITE FACILITy BREATHER FILTER XEROSOL TEST DATA
APPENDIX w, 6241-v CROSS SITE FACILITy B8imTHER FILTER AEROSOL TEST DATA
APpENDIX w, 213-w RETENTION TAXK BREATHER FILTER AEROSOL TEST DATA SHEETS
BREATHER FILTER IN-PLACE LEAK TEST (ARROSOL TEST)
PoRTABLE BREATHING AIR CC41PRF.SSORS(HO-64-3848 AND -3849) CARBON MONOXIDE
1NSPECTION OF CATHODIC PROTECTION SYSTEM RECTIFIERS
4SO-VOLT FEDERAL PACIFIC CIRCUIT BREAKER 1NSPEC!TIONAND TESTING
ELECTRIC MOTOR 1NSPECTION
Low VOLTAGE ELECTRICAL DISTRIBUTION SYSTEM INSPECTION AND TESTING
INSPECT AND TEST SWITCHBOARD SB-1 480-VOLT POWER CIRCUIT BF2ZAKBRS FoR AEPL
1NTERNATIONAL POWER MACHINES, MODEL 1BP+1O NNINTERRUPTAELE POWER sUPPLY, c
AUTO-TRANSFER SWITCH, ZENITH CNTL ZTSH SERIES lNSP
FW.LEASEDATE STATUS_________ ----------
R3V1SING
REV1SING
REVISING
F23V1SING
REVISING
REVISING
REVISING
REVISING
REVISING
R37J1S1NG
BEVISING
REVISING
BIVISING
FW.VISING
EEV1SING
REVISING
REV1SING
REV1SING
REV1SING
4/03/98 ACTIVE
2/27/98 ACTIVE
6/05/98 ACTIVE
10/31/97 AcTIVE
10/31/97 ACTIVE
HNF-341!I,Rev. O
12
7/27/98 Master Index of Active and Developing Page 5Tank Farm Operating and Maintenance Procedures
B
B
B
B
B
1
B
B
A
A
B
c
F
c
D
B
c
c
A
B
A
c
E
F
--- .-------------------------------------------------------------------------PRCCEDU=. NUNBER REV REV# PRCCEDURE TITLE---------------- ---5-EDs-383
5-EGEN-063
5-EGEN-332
5-EFc6R-062
5-ENER-089
5-EMER-194
5-EM2R-366
5-FAcE-330
5-MIsc-127
5-MIse-285
5-MISC-285
5-MISC-297
5-MISC-299
5-MISC-305
5-MIse-306
5-MIse-315
5-MIsc-331
5-MIsC-375
5-sA-139
5-SA-31O
5-sHN-266
5-TCD-307
5-VTP-076
6-cAss-313
o
0
0
0
0
D
o
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
NEED TITLE
HONDA Es-6500 GENERATOR PREVENTIVE NAINTENANCE
ArlAZ VENT1LATION AND CCGLING STANDBY GENERATOR MONTHLY PFC3VENT1V&MAINTEN
REMOTE EMERGENCY SIEEN LCCAL CL2AN1NG AND 1NSPECTION
1NSPECTION AND CLEANING OF EXIT LIGHTS FOR WEST TANK FARMS
FIRE ECf3R1NSPECTION
Encon Portable Eyewash stations, lnspectionlMaint enance
LOAD TEST 272-AW MONORAIL HOIST [EH-01)
PEDESTAL AND BENCH GRINDER 1NSPECTION - WEST MAINTENANCE SHOPS
INSPECT REPLACEMENT CROSS SITE TRINSFER SYSTEM AIR CCMPEESSORS AND AIR DRY
INsPECT REPLACEMENT CROSS SITE TRANSFER SYSTEM AIR COMPRESSORS AND AIR DRY
1NSPECTION OF OVERHEAD CCORS
PORTABLE TOOLS AT 272-wA NAINTENANCE
DRY WELL VAN CCMPUTER BATTERS BACKUP FUNCTIONAL TEST
1NSPECTION OF DRY WELL VAN PROBE CONNECTIDNS AND BCC14PENDANT SWITCH
CONDUCT VISUAL 1NSPECTION OF SODIUM HYDROXIDE (NaOH] TANK TRUCK 68C-4347
ACOUSTIC PROBE FOR DRY WELL VANS
PF23VENT1VEMRINTENANCE OF LEAK DETECTOR CAISSON BLOWERS AND HOISTING 1.5CHP.
INGERSOLL-SAND 200 HP AIR COMPRESSOR SEMI-ANNUAL MAINTENANCE
SEMI-ANNUAL AIR COMPRESSOR 1NSPECTION - 204-AR (#1)
PREVENTIVE NP.INTENANCE FOR HYDRCX3ENMONITORING SYSTEM GAS SAMPLE CONDITION
mAL T2MPER4TU~ AimnlNGs FOR w2sT TANK FARMS
BREATHER FILTER REPAIR AND REPLACEMENT
FUNCTIONAL TEST OF ass ALAWS FOR POWER CONDITIONING SYSTEN - 2750E BUILD
RELER3E DATE
5/18/98
3/0’7/98
5/28/98
STATUS---------.
REVISING
REV1SING
R3V1SING
RXV1SING
RF.V1SING
ACTIVE
AEV1SING
REVISING
DEVELOPING
ACTIVF.
REVISING
REVISING
REVISING
REVISING
RIV1SING
REV1SING
R3V1S1NG
REVISING
DEVELOPING
REV1SING
ACTIVE
REV1SING
REVISING
REV1SING
HNF-341O, Rev. O
13
-——__r—_— .————____________________________________________________________ ______________________________________ - ~=__ ___7/27/98
----------
Master Index of Active and Developing
----......
Tank Farm operating and Maintenance ProceduresPage 6
-=======-------------= =====================______=========____------------- ------ -----------
pRCCEDURE NUMEER REV EBV# PREEDUS.E TITLE SELERSE DATE---------------- --- --- -------------------------------------------------------------------------- ---------
6-cA2s-314 E
6-cvT-329 A
6-CVT-304 B
6-CVT-411 B
6-CVT-447 B
6-cV’l’-472 B
6-uT-474 B
6-CVT-476 B
6-cvT-515 B
6-cvT-517 B
6-cvT-519 B
6-cvT-520 B
6-cvT-527 B
6-cvT-538 B
6-FcD-385 A
6-FcD-481 B
6-FcD-510 B
6-GEN1-O1O c
6-GEN1-131 B
6~GEN1-135 B
6-GEN1-294 B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2750-E ~S P0W2EBL0C POWER COND1TION1NG SYSTEM
cALIBmTE FISHER-ROSENOUNT MoDEL 3044cA115M5 TENPE8ATusE TEAN2M1TTER 5/22/98
BA1LEY 7000 VOLTAGE TO FREQUENCY CONVERTER MODEL 741 CAL1BWTION PRCCEDU83!
ACRCMAG SERIES 800 PNEUMATIC CONVERTERS CRL1BSATION PRDCEDUSE
ROBERSHAW MODEL 443 AND 445 ELECTRO-PNEUM4T1C CONVERTER CAL1BSATION PROCED
CALIBRATE DIFFERENTIAL PEESSURE TWSNITTERS FOR 242A
cAL1B6ATE ELECTRONIC PRESSURE MD DIFFE=NTIAL P8ESSUAE TWSMITTER LESLIE
CALIBRATE EMERSON-TYPE MAGNETIC FLOW SIGNAL CONVERTERS SERIES 7000
Bailey Model 140 Millivolt Converters
FAIRCHILD MODELS T-51OOB-1 . T-51OOB-4, 5200 AND T-5600 1/P TRANSDUCERS CAL
TELMRR, SERIES 500 MILLIVOLT-TO-CURRENT TRRN3N1TTER CRL1BRATION PRCCEDURE
FOXEORO E69 SERIES C!UARENT-TO-PNEUT4AT1CCONVERTERS AND POS1TIONS CJ+LIBPAT1
E OR 1/P CONVERTER CAL1BSATION PR02EDURE 1/14/9s
BRCOKS MODEL 3560, SERIES 111 NAG-FLOW CONVERTERS CRLIBEP.TION PRCCEDU8E
CALIBRATE ANC MASS TRON 11 5/12/98
CALIBEATE NAESH-MCSIRNEY, MODEL 250 FL0h?4ETER
AIR ROTCt.5TERCAL1BSATION
plsHER CONTROL, CAGELESS 249 SERIES DISPLACER sENsOR MAINTENANCE
CALIBRATE ALRSM MODULE
GENERIc CALIBWTION OF DIGITAL lNDICATORS
TAYLOR MIDEL 1015N AND 1016N ELETRoNIc ALEAN CRL1BSATION PRCCEDUSJ
STATUS----------REVISING
ACTIVE
EEVISING
RBVISING
REVISING
8EVISING
8EVISING
F.EVISING
EEVISING
RPVISING
REVISING
ABVISING
AcTIVE
WVISING
ACTIVE
8EVISING
EEVISING
k2VISING
EEVISING
EEVISING
EEVISING
CALIBILITEABB KENT-TAYLOR MODEL 2050R INDICATING PRocESS CONTROLLER=;~#~<~&q*:, ,Y,,.““’.**x#m:$m.m%zwE2%#EmxaBw~;+’+x6R*?y$.wx6*CALIBRJLTELFE MODEL 371-K INDICATORS WITH CUEEENT INPUT
CALIBSATE TRIPLETT MODEL UB120-14-1-G TILT POS1TION INDICATOR 5/12/98 ACTIVE
HNF-341O, Rev. O
la
-———————-=.= .________====.=====s=========.=====s========.======s===.=.===.-—--___——---------7/27/98 Master Index of Active and Developing
—--_-_-.——
Page 7Tank Farm Gpezating and Maintenance Procedures
PRccEDURE NWNEER RI.V A2V# PROCEDURE TITLE---------------- --- --- --------------------------------------------------------------------------6-GEN1-354 B 0 BAILEY 7000 DUAL ALARM, MODEL 744 cALIBmT1ON pREEDu-
6-GEN1-377 A 0
6-GEN1-451 B 0
6-GENI-453 B 0
6-GENI-459 B 0
6-GEN1-411 B 0
6-GEN1-475 B 0
6-GEN1-478 B 0
6-GEN1-479 B o
6-GEN1-480 B 0
6-GM-143 B o
itz2~*’j@~~$~+~~S@.*-...+_.
6-LDD-286 B 0
6-LDD-319 B 0
mwFs*%:$@3%@z2$lY&
@w.mw.w&xI-im
&w*x**xfw#mwK*H
6-MIse-142 BO
6-MIse-281 A 1
6-MIse-282 Al
6-MIsc-292 D o
6-MIsc-298 B 0
RELEASE DATE STATUS--------- ----------7/21/98 ACTIVE
CALIBRATE KINEt.fi.TRICSMODEL TS-33MOD SEISNIC TRIGGER 5/22/ 98 ACTIVE
PD690 DIGITAL PRCCESS NZTER CALIB~T1ON 5/27/98 AcTIVE
CALIBRATE LESLIE MODULE 610323L LIMIT ALARMS REVISING
TAYLOR INDIcAToR AND INDIcATING CONTROLLER, SERIES 1300 CAL1BSATION PRDCED REVISING
McORI PRODUCTS SERIES 72 VALVE POS1TIONER CAL1BFL%TION REVISING
CALIBRATE MA20NE1LAN ELECTO PNEUNATIC TRANSDUCERS MODELS 8005 AND 8006 REV1SING
CALIBRATE YEW SERIES 80, MODELS SLPC AND SLCD PRcGAAM4A3LE INDICATING CONT REVISING
CALIBRATE BAILEY 1000 SINGLE POINT INDICATOR, MoDEL 730 REVISING
CALIBRATE TAYLOR MICRO-SCAN INDICATING CONTROLLER, 1300 SERIES REVISING
BRUEL & KJAER 1302 MULT1-GA2 MONITOR CALIBRATION DEVELOPING
CALIBRATE THE D1UEK21ON BOX AND VENT STATION SUMP PUMP LEAK DETECTION ELEM 4/02/98 ACTIVEE~%.%_*2t_-.~~g~.-~~~;~=~S.=~=~mFW&%~JWXW@.@MDFORD-BUILT SURVEILLANCE PULSE ANPLIFIER DISCRIMINATOR ipms ) USED IN L
ROBERSSAW MODEL 185A (RI PREC1S1ON GAUGE CAL1BRATION PROCEDURE REVISING
.=k@e’=&:w@sPEwmKmmm%*%P84’03”8FOXBORO 1FL1O-1 $8 FLANGED LEVEL TRANSMITTER CAL1BRATION*j*;~*;~#@&.
ACTIVE
VISPAK 500 DIGITAL PROCESS INDICATOR REVISING.“...& .%w%% .“:.,,.
=60/ 161 %%%%%oN ~={_~- RF.VISINGmww~-=mR@HEsTER lNsTRmNT SYSTEMS, SIGANL TRANSMITTER, MODEL SC-1300 REVISING
CAL1BRATION OF PANA1.CiTRICSMODEL DF868 ULTRASONIC FLOW INDICATOR TRANBNITT 4/03/98 ACTIVE
CAL1BRATION OF THE FOXEORO MODEL 1MT25 1/A SERIES MAGNETIC TRAN3N1TTERS FE 4/03/98 ACT1V2
ADJUSTMENT FOR CAM MODEMS AND AMPLIFIER IN 200 AREA TANK FARMS REVISING
1NSPECTION AND CLEANING OF THE PCS MICRO CCMPUTER REVISING
6-MIse-336 A o
6-MISC-394 A o
AY/A2 CENTURA VALVE AI,lGNFTiNT& SERVO CAL1BRATION REVISING
CALIBRATE AMC VEL-TROL 11 5/22/98 ACTIVE
HNF-341O, Rev. O
15
------7/27/ 98
-.-_—_-————————————_____ —---------Master Index of Active and Developing
Tank Farm Gperatirq and Maintenance ProceduresPage 8
------- -------
pRCCEDURE NUNBER R3V R3vf pRCCEDURE TITLE =LEAEE DATE________________ ___ ___ ------------------------- .- _______
STATUS
6-pcw054 B o
6-PcD-079 B 0
6-PcD-082 B 0
6-PcD-114 B o
6-PCD-117 B o
6-PcD-118 BO
6-PcD-120 A 0
6-PcD-132 B o
6-PcD-133 B 0
6-PcD-140 B 0
6-PcD-165 B 0
6-PcD-166 B 0
6-PcD-167 B 0
6-PcD-176 B 0
*m%%’2’Nw.M$$jwq
6-PCD-263 B 0
6-PcD-267 BO
6-PcD-269 B 0
6-PcD-274 B o
6-PcD-280 A o
6-PcD-302 B o
6-PcD-339 B 1
6-PCD-361 B 1
6-PcD-369 B o
CALIBRATE “ONE TINS USE” PRESSURE GAUGES
FOXBORO 613 DL AND SERIES E13, D/P CELL TRANsMITTER, CAL1BRATION PROCEDURE
REPUBLIC P03000ccE SERIES PNEUNATIC PRESSURE TF%t$NITTER
HONEWELL ELECTRONIK NON-INDICATING PNEDMATIC TRAN3M1TTER, MODEL YI58N31
DWTER INSTRUMENTS 600 SERIES D1FF2WNT1AL PEESSURP TAANSNITTER
.M4ETEKMODEL 572 MBTER/cONTROLLER
CALIBRATE ROSENOLINTMODEL 3051c D.P. PRESSURY.TRANSNITTERS FOR ENRAF
ZERO AND SPAN ADJUSTABLE INSTRUMENTS WITH PP.EssuR2,CURBNT, VOLTAGE, AEsIs
FOXBORO ELECTRONIC P3ESSURI TRAN5N1TTERS
BAILEY ELECTRONIC DIP TRRNSNITTER TYPE BC SERIES
TAYLOR INSTRUMENTS, DIFFERENTIAL PRESSURE TRANENITTERS, TYPES 3302T, 3303T
FISCHER AND PORTER D1F3’2EE,NT1ALPRESSURP.TRANENITTER MODEL 1494, SERIES 10
TAYLOR DIFFERENTAIL PRESSURE TRAN3M1TTER, MODELS 3402T, 3403T, 3404T, 3406
TAYLOR 300 SERIES D1FFER2NT1AL PAF,SSUW TRANSMITTER
P.EV1SING
P.3V1SING
P.EV1SING
DEVELOPING
REVISING
REVISING
DEV2LOP1NG
F23V1SING
REVISING
7/21/9S ACT1V2
R2V1SING
REV1SING
F.EV1SING
RBVISING
ROSEMOUNT MODEL 3051C DIFFERENTIAL WD GAGE PF.ESSURBTRAN3N1TTER USING MOD 5/11/98r-wiw.w.w&Y-.w&wh%Txz?:w~
ACTIVE:z*?rR*xKR*&m.enT4a?Mgv~sgx$m-ws%E,mRx?#
WALLACE AND TIERNAN PNEVMATIC TYPE NU-820 CALIBRATIOti PRCCEDURE
F0x60R0 pNEUNATIC INDICATORS SERIES 110 MD 135 MANUAL STATIONS
HONEYWELL PNEUNATIC DIFFERENTIAL PRESSURI TRANEMITTER SERIES 2900
TAYLOR DIFFERENTIAL pmssuw TW2MITTER 1300T SERIEs, MODEL B CALIBaTION
CAL1BRATION OF A14ETEK PRESSURE TRANENITTERS 88C SERIES
BARTON FcX SERIES TF.ANSMITTER cALIB~T1ON PRCCEDURE
FOKBORO MODEL 843DP DIFFERENTIAL PP3ssupa TRANSMITTER mLIBWTION
MASS-TRON FLOW TP.AN2N1TTERCAL1BRATION
CALIBRATE LARGE AND SNALL PNEUNATIC GAUGES
REVISING
6/05/98 ACTIVE
REVISING
3/06/98 ACT1V3
10/31/97 ACTIVE
2/26/98 ACT1V3
11/13/97 ACTIVE
RIV1SING
HNF-341O, Rev. O
16
--------- ------ -----------7/27/98
-=====s======____========.==. .============.=----Master Index of Active and Developing
Tank Farm Uperating and Maintenance ProceduresPage 9
===================________==============================______-------- ----- -----
PROCEDURE NvN8ER 8Ev Aw# PRCCEDURE TITLE ~LERSE DATE---------------- --- ___ _______________________________________________ ---- _________6-PcD-373 B 0
6-PcD-393 A o
6-PcD-431 B o
6-PcD-458 A 0
6-pcD-460 B 0
6-PcD-508 B 1
~%fi3&wtmi/F4*3
$-*K%%%$R-8
FOXBORO DIFFEP.ENTIAL PRESSUR3 T8AMU41TTERS SERIES 13, 13A, 13H, mD 15
CALIBRATE BARTON MODEL 289A DIFFESENTIAL PRESSURE INDICATING SNITCH 5/12/96
D1F~R2NTIAL PRESSURE LC.3PVERIFICATION TEST DATA SHEETS
CALIBRATE PRESSURE SWITCHES
WESTINGHOUSE PSESSUE3 TRANSMITTERS, MODELS 56PL, PM, AND PH CALIBRATION
D1Apfirw+t4OPERATED Pmssum WlTCHES 10/02/97
CALIBRATE PRUCEDUR3 BA1LEY PLRTINUM STANDARD Wl%&~~~%&~ MOmx$w$~~~~wwmmLEEDs ANN NORTHRUP SPEEDCMAX G, n, RND w @_-
TY;E F.9221, TYPE RD222
STATUS-____-.-_-EEVISING
ACT1V3
EVISING
DEVELOPING
REVISING
ACTIVE
DEVELOPING
E3V1S1NG
REVISING
REvlsING
FOXRORO W70.S-1S,.RTW.C~~ ;,.,- . P.EVISING
iw3wwi-w?wwx 6/05/98 ACTIVE
M NAAl”lll ~7T-
R3VISING
~ RNrii50D -~~~@ R3V1S1NG
Mw~w~- RXVISING
%%%%%%? CALIBSATmN PRWEDURX REVISING=%%”%%55RC SERIES CAL1BRATION PRCCDURE
–-”—”WWREVISING
USED IN SHIM CABINET CALIBIV+TION pRCCEDU=.~7p;p:-:%T ~ ~“ v
8/27/97 ACTIVE
~Mi?w:wiSEVISING
ACTTVF
HONEYWELL YI53x64 TEMPERATURJ7mCORDER CALIBRATION
~*R:~-*$arwM;*McALIBRATE CHESSELL MODEL 345 3-CnANNEL RECORDER
=bw-B~%,wK<&m
ACTIVE
REVISING
REV1SING
HNF-341O, Rev. O
17
-————————-—-------- ------ ----7/27/90 Master Index of Active and Developing
---—--—.. .-——______—___
‘YankFarm Cperatinq and Maintenance Procedure.Page 10
==.=-==================----------.===.=.-.-.-.-.--.-==.=.=.======.===._._._.__.=.=.=.===.=....-==.=.==_...._.========----==========_______.____=============---------- ---------- ------- ----
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
PROCEDURJ NUMBER REV IWV$ PRDCEDURR TITLE P.ELEABEDATE________________ ___ ___ ------------------------------------------ --------
w--wwmwM;wifi ~% F~~lBRATE SAIC/XADeCO, HI-Q ENVIRONMENTAL AND
_________
- ‘~-s”pLE ‘“-iw#=’*2~**~&Ta .i .,...,:..MW*X*6-RN-190 B HARSHAW, MODEL NR-25, LCGARITIN41C-LINEAA 8ATEMETER, CAL16RRT10N PRCCEDURE
6-RM-290 B
6-RM-541 B
6-TcD-086 B
6-TcD-087 B
6-TcD-116 B
6-TCD-I30 B
6-TcD-137 B
6-TCD-161 B
6-TCD-181 B
6-TCD-249 A
6-TCD-311 A
6-TCD-312 B
6-TcD-322 A
6-TcD-323 A
6-TcD-327 A
6-TcD-328 A
6-TcD-395 A
6-TcD-399 B
6-TcD-407 B
6-TcD-427 B
6-TcD-450 B
6-TcD-462 B
CANBERRA LIN/LcG EATE1.5TERMODEL 1481L
ELECTRONICALLY CALIBRATE VICTOREEN, G-M AREA MONITORING SYST2M, MODEL 855/
ROBERTSRAW, TR-I 000 SERIES, T2MPEEATURE REGULATING VALV2
WESTON MODEL 4303 AND 4503 DIAL THERMCI.Y2TERSCALIBRATION PRCYCEDURE
ACTION PAK INSTRUMENTS WITH RTD AND BRIEGE INPUT AND VOLTAGE/CUARENT OUTPU
ACTION MIDEL 4041 RTD D1FFEEF,NTIALTEMPERATURE TRANSMITTER CAL1B8ATION PRO
Ct.5GASERIES HH-99A XAND HELD DIGITAL THERMCt.5TER
CALIBRATE LOVE CONTROLS TEMPERATURE ALARM SWITCH MODELS 48, 49, AND 50
CAL1BRATION PRCCEDURE FOR TE14PERATURX3W1TCH
RDF TEMPERATDRI TRJ+12N1TTERMODELS 2800 AND 2900 ADJUSTMENT AND CAL1BFQ.TIO
WASTE TANK NAINTENPJJCE PROCEDURE, FOKBORO MODEL 893RA-Q TENPERATuxE TRAN3N
WASTE TANK MNTENANCE PRCCEDURE ~TLOW MODEL 98s TEMPERATURE CONTROLLER c
CAL1BX4TE CHRCMALOX MODEL 2104 TEMPERATURE CONTROLLER
CALIBFQ!TECHRCMALOX MODEL 3101-11000 OVERTEMPERATURE INDICATING 2W1TCH
CALIBRATE DEVAR MoDEL 2M-812/M371/18P1X TEMPERATURE TRAN3M1TTER
CALIBRATE DEVAR MODEL 18-328 ALARM
CALIBRATE PYRCI.C+TIONMoDEL R1T185L TEMPERATURE TEAN2N1TTER
CM2GA DIGITAL TEMPERATURE INDICATOR, MODEL 199, CALIBRATICPN PRCCEDUXE
CHRCMALOX 3914 EXHAUSTERS HEATER cONTROLS, 241-AP TANK FAit-1CALIBIU+TIONPR
FENWAL SERIES 543 THERMOCOUPLE SENSING TENPERATUR2 CONTROLLER CHECK
PD750 UNIVZRSAL TEMPERATUP3 NiTTERw1B8AT10N
WITED ELECTRIC TEMpERATUiT3 CONTROLS, TyPES B1lO, BIIO.4,cllo, CIIDA, MD
7/14/98
7/14/98
10/31/97
2/25/98
1/13/98
5/13/98
5/11/98
5/12/98
5/12/98
5/13/90
5/21/98
STATUS----------
REVISING
REVISING
REVISING
ACTIVP.
REV1SING
REV1SING
REVISING
3EV1S1NG
REVISING
ACTIVE
R2V1S1NG
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
AcTIVE
AcT1V2
ACTIVE
REVISING
DEVELOPING
REVISING
ACTIVE
XEVISING
HNF-341O, Rev. O
18
.==.—-======s. .====-----=======m===============.========...=================.----- -========_---=================.==============_-_-----===.7/27/98
----
M.aster Index of Active and Developing Page 11Tank Farm ~eratinq and Maintenance Procedures
-----
PRCXEDURE NUMSER REV RSV# PRCCEDURE TlTLE REL2ASE DATE---------------- --- ___
6-TcD-463 B 0
6-TcD-464 B 0
6-TcD-466 B 0
6-TcD-473 B 0
6-TCD-506 B 0
6-TcD-512 1 0
6-TF-001 1A
6-TF-004 2 A
#E~F2%%%;!&B%m
6-TF-O1O 1A
6-TF-011 2B
6-TF-013 1A
6-TF-014 lB
6-TF-018 2 0
6-TF-022 2A
6-TF-029 2 A
#iw#n3#&i~wixM
6-TF-037 ID
6-TF-037 2 0
6-TF-040 0 0
6-TF-042 5B
6-TF-044 1 0
6-TF-049 lB
6-TF-052 OB
__________________________________________________________________________-------- -Ex3R1cD1G1TR2ND 220 AND SATELLITE 221 TEMPERATURE MONITORING SYSTEN
AcT1ON PAK THERMOCOUPLE INPUT zERO psA2E FIRrNG CONTROLLERS, MODELS AP2220
HONETW2LL Y-152-P SERIES, DIFERSNTIAL TEMPERATURE CONTROLLER CALIBRATION
CALIBRATE THP.3E-WIEF RESISTANCE TEMPESATU~ DETECTORS (RTD )
SOLITECH MODEL R59A-105 D1F3’ER2NT1ALTEMPESATUR2 ALARM 9/12/97
Thernwn Cent ET-HL-1, ET-0600 & Love Limit .ont 48, 49 & 50
HANDLING RND HOOKUP OF TRNK FARMS PUMPS 12/10/96
PB-1 PD?4PREPAIRS, 242-A EVAPORATOR 12/10/96
CP.LIBSATIQN OF TENNELEC LB5500/W SERIES ALFHP.IBF.TACCXJNTERSmm%fw&~w*~ ?g%mgwFISHER CONTROL, CAGELESS 2i9 SERIES DIsPLACER SENSOR NAINTENANCE
1/17/97
12/10/96
NAINTENANcE OF FISHER CONTROLS, 2500 SERIES LEVE-TROL C0NTR0LLER/TRAN2N1TT 12/10/96
NAINTENRNcE OF SPRRLING M2TER, SPARLING 37770, HIGH TENsILE X-290 12/10/96
TANK FASN RUN-IN TEST FoR SUB15RS1BLE AND FLYGT PVMPS 12/20/96
THERMOSTAT FuNCTICNAL TEST AND 1NSPECTION 8/14/95
SEPAIRING LARGE COAXIAL CABLE FOR CCMPUTER AUTCS4ATED SURVEILLANCE SYSTEN T 12/20/96
lSOTOPICALLY V2R1FT THE A08 PND 401 OFF LINE LIQUID MONITORS 12/20/96
TROUBLESHCOTING RND REPAIR TO LIQUID LEVEL GAUGES (FIC vS)
@~K~m%’mmmw%@3.wwlNSpECT WELDING EQUIPM2NT
12/04/97
2/26/98
INSPECT WELDING EQU1PM2NT
TROUBLESHCDT AND mPAIR mclATOR PRNELS lN THE TANK FAf04FACILITIES, 20 6/18/91
TESTING OF LIQUID DETECTOR [LDE & LLE ) 4/07/98
48D-vOLT F2DEsAL PACIFIC CIRWIT BEEAKER INSPECTION AND TESTING 11/28/94
BOLT TORQUING GUIDELINES 11/12/97
FUNCTION?.LTEST OF ACTION PAK MODEL AP1624 LIMIT ALARM MODULE IN PUMP CONT 1/02/97
STATUS----------
EEVISING
RSV1SING
3i2VISING
REV1SING
ACTIVE
REVISING
ACT1V2
ACT1V2
ACT1V2
ACTIVS
ACTIVE
ACT1V2
AcTIVE
AtiT1V2
ACTIVE
ACTIVE
ACTIV2
ACTIVE
R2VrSING
ACT1V2
ACTIVE
ACTIV2
ACT1V2
ACTIVE
HNF-341O, Rev. O
19
7/27/90
.—___ ----
Master Index of Active and DevelopingTank Farm operating and Maintenance Procedures
Page 12
==========================_________=========________===============_____-------- ---- ---------
PROCEDURE NUMBER REV AEV# PRCCEDUSJITITLE------.--------- -.. ___
RRLEASE DATE STATUS-------------------------------------------------------------------------- _________ ---------.
6-TF-054 1A CAL1BRATION OF ‘ONE T1!.fZUSE- P~SSUF.E GAUGES 2/26/98 ACTIVE
6-TF-055 lC
*wg$#%%wmx?M*3f$
6-TF-057 1 0
6-TF-058 2G
6-TF-059 1 A
x*;q#M:Kw;wiMKw&w
6-TF-062 0
6-TF-063 0
6-TF-064 1
6-TF-065 3
6-TF-066 0
6-TF-068 0
6-TF-071 0
6-TF-072 0
6-TF-076 3
6-TF-077 1
6-TF-0s4 1
6-TF-0s5 1
6-TF-0s9 0
6-TF-094 1
6-TF-105 0
6-TF-111 0
6-TF-112 0
0
0
G
c
c
0
G
B
c
F
A
B
B
E
A
c
A
TR0UBLESHCK3TING & sm~R OF LIQUID DETEcTOR (LnE 6 LLE j 5/16/96 ACTIVE
~~/CAL OF STANDARD DRY WELL MONITORING VANS
~H#%”%-mM:B$~:e?.%E+”mLw2Di’y‘W:li van Probe Maintenance and calibration
9/27/96 ACTIVE
8/29/95 ACT1V3
Verification of FIC Reference Elevation 1/09/98 ACTIVE
T..nele. Model TC-213 Linear Amplifier and Integral Discriminator Calibra 1/02/97 ACTIVE
Preventive Maintenance/calibration of Horizoyaly Lateral M.nitoring,~ystem#+f#&*y&.W.
2/04/93
~Ew&w~~w&:m%?s@m;~
ACTIVE
Remote Emergei&S~i% Local c1ea”ing and lnsPectionxw#eK%yT ~w
Honda ES-6500 Generator PM
.JoyWGOL and WGAPOL Oil Free Air compressor Annual Maintenance
AIR COMPRESSOR 1NSPECTION
Dry Wel1 %. cable Reheading
AW270-2 Calibration Procedure for Pressure Alarm 3witch PP.2-102-3
Validation of Multlple-finction Instrument Tree (MIT) Thermocouples with v
Testing of Leak Detectors LDE-MPZ-42-1 , and 44-1 i“ 242-A Retention Basin
BREATHER FILTER m.iova 6 MpLRCEMXNT
Stack sampling and Monitoring system Maintenance
lmgersoll-Rand Type-30 Oil-Free Air compressor Inspection
lnqer.soil-RandType-30 Oil Free Air Compressor Maintenance
Inspection of Exit Lights for WTF
Regenerative Air Dryer Impe.tie” and Maintenance
Field Calibration of Stevens Total Flowmeter, Model 61R
4/02/93
3/19/91
6/05/97
9/30/96
5/11/93
3/19/98
1/02/97
9/25/91
7/23/98
6/13/94
1/10/97
2/21/98
1/10/91
2/27/96
ACTIVE
ACT1V2
ACT1V2
ACT1V2
ACT1V2
ACT1V2
ACT1~
ACTIVE
ACTIVE
ACTIVE
ACTIV2
ACTIV2
ACTIVE
ACTIVE
Maintenance and/or Replac:ne~t of mlR Optical Bench and Sample Cell for 2
~m:--$%?~%w.~ ~m~mz6m@x4i~
3/02/9S ACTIVE
Malnte”ance and/or Replacement of G>. Chmnatograph (Gc-31) for 241-SY-101~m:p~~-=
HNF-341O, Rev. O
20
.=====.=====. .———————————————____________________________=___________________________________________________________======.==____r_____1/21/90 Master Index of Active and Developing
Tank Farm operating and Maintenance Procedure.Page 13
----------------- —---- -------- ---.——..===
PRCCF.DUXENUNBER REV XEVU PRCCF,DURETITLE XELEAEE DATE STATUS---------------- ___ ___ ------------------------------------------------------ ----- --------- ----------
S-TF-143
6-TF-152
6-TF-155
6-TF-155A
6-TF-155AA
6-TF-155AB
6-TF-155Ac
6-TF-155AD
6-TF-155AE
6-TF-155AF
6-TF-155AG
6-TF-155AH
6-TF-155AI
6-TF-155AJ
6-TF-155AK
6-TF-155A16
6-TF-155AN
6-TF-155A0
6-TF-155AP
6-TF-155AQ
6-TF-155Aw
1
1
111
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A
A
F
G
c
D
D
c
D
D
D
E
c
E
D
D
c
B
D
c
c
Remval, Repair, and Installation of Camera/Light Rssembly at Riser 5B of 3/02/98 ACT1V2
PORTRBLE AIR BXEATHING CDNPXESSORS (HO-64-3848 & 38491 MAINTENANCE 9/08/95 ACTIVE
Enraf Series 054 Preventive Maintenance and Calibration 3/02/98w,~@mLwMw.%%?mMmF#H@imm~
AcT1V2mm-g
BRUEL AND KJAER (B&K) 1302 3TACK PMNONIA MONITOR CAL1BRATION
mw’%#Z%%k% .....“w@-mF@Kw@w2~*DS Series Circuit Breaker Inspection and Testing
244-u WRT STACK AIR FLOW~*~~~~w~;@~%$-E%;*:~~%AppENDIX A, 241-M TANK EXKAUSTER STACK 296-A-29 AIR FLOw TEsT DATA SHEETS
APPENDIX AA, 204-AR EXHAUSTER STACK 296-A-26 AIR FLOW TEST DATA SHEETS
APPENDIX AE, 241-A-702 AY/AZ TANK ExxAusTER sTAcK 296-A-17 AIR FLOW TEST D
APPENDIX AC, 241-A-702 AYIA2 BACKUP TRNK AIR FLOW TEST DATA SHEEiS
APPENDIX AD, 241-AN ANNULUS EXXRUSTER STACK 296-A-30 AIR FLOW TEST DATA SH
APPENDIX AZ, 241-AP ANNULUS EXBAUSTER STACK 296-A-41 AIR FLOW TEST DATA SH
APPENDIX AF, 241-Aw.ANNuLus EXXRUSTER STACK 296-A-28 AIR FLOW TEST DATA SH
APPENDIX AG, 241-AY 101 ANNULUS EXXAUSTER STACK 296-A-18 AIR FLOW TEST DAT
APPENDIX AS, 241-AY 102 PNNULUS EXXRUSTER STACK 296-A-19 AIR FLOW TEST DAT
ApPENDIX AI, 241+.2 ANNULUS EXSAUSTER STACK 296-A-20 AIR FLOW TEST DATA SH
ApPENDIX AJ, 241-c-105/I 06 TANK EXXRUSTER STACK 296-p-16 AIR FLGW TEST DAT
APPENDIX RK, 241-SX TANK EXHAUSTER STACK 296-S-15 RIR FLOW TEST DATA SHEET
APPENDIX RM, 242-s HOT CELL ExKAusT STACK 296-s-1s AIR FLOW TEST DATA SHEE
APPENDIX RN, 242-T BUILDING ExKAusT STACK 296-T-17 AIR FLOW TEsT DATA SHEE
APPENDIX AO, 244-AR CANYON EXHAUSTER STACK 296-A-Lz ArR FLOW TEST DATA SHE
APPENDIX AP, 244-CR VAULT EXHAUSTER STACK 296-C-5 AIR FLOW TEST DATA SHEET
APPENDIX AQ, 209-E CELL 6 BUILDING EXHAUST STACK 296-P-31 AIR FLoW TEST DA
APPENDIx AW, 213-w COMPACTOR BUILDING EXHAUST STACK 296-w-3 AIR FLOW TEST
HNF-34.1O,Rev. O
21
1/30/97
7/14/98
2/23198
1/01/98
1/06/9S
1/06/9S
4/27/98
4/27/90
4/27/98
4/14/98
7/22/90
1/06/98
2/24/98
12/23/’97
12/23/97
12/23/97
1/06/98
1/06/98
1/06/98
1/06/98
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVS
ACTIVF,
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
---------- ==. ----- ----- ------------7/27/98
_-_-__-.-.———
Master Index of Active and DevelopingTank Fam Cperating and Maintenance Procedures
_____
Page 14
------- -__--_-_-—- .===——_——————————=.=========.=================.=======._——_________
PROCEDUKF mER REV XEV# PROCEDURE TITLE---------------- ___ ___ ----. ---. --————---—--6-TF-155B
6-TF-155c
6-TF-155D
6-TF-155E
6-TF-155F
6-TF-155H
6-TF-1551
6-TF-155J
6-TF-155K
6-TF-155L
6-TF-155M
6-TF-155N
6-TF-1550
6-TF-155P
6-TF-155Q
6-TF-155s
6-TF-155T
6-TF-155u
6-TF-156
6-TF-156AA
6-TF-156AB
6-TF-156Ac
6-TF-156AD
6-TF-156AE
1
1
1
1
1
1
1
1
1
1
1
A
A
1
1
0
1
A
0
0
0
0
0
0
F
E
c
D
D
E
D
D
D
c
D
1
2
D
c
o
c
o
E
c
c
c
D
D
APPENDIX B, 241-AP TWK EXXAUSTER STACK 296-A-40 AIR FLOW TEST ~TA SHEETS
AppENDIX c, 241-Aw TANK EXHAUSTER STACK 296-A-27 AIR FLOW TEST DRTA SHEETS
AppENDIX D, 241.sY ANNULUS EXHRUSTER STACK 296-A-22 RIR FLOW TEST DATA SHE
APPENDIX E, 241-sY TANK EXHAUSTER STACK 296-P-23 AIR FLOW TEST DATA SHEETS
APPENDIX P, 241-sY BACKUP EXHAUSTER sTACK 296-P-28 AIR FLOW TEST DATA SHEE
APPENDIX H, 244-A TXRT EK41AusTER STACK 296-A-25 AIR FLOW TEST DATA SHEETS
APPENDIX 1, 244-BX DcRT EKKAUSTER STACK 296-B-28 AIR FLOW TEST DAT,D,SHEETS
APPENDIx J, 244-S iXRT EXHP.USTERS STACK 296-s-22 AIR FLOW TEST DATA SHEETS
AppENDIX x, 244-Tx DCRT EXXAUSTER STACK 296-T-18 AIR FLOW TEST DATA SHEETS
AppENDIX L, 244-u ECRT EXKAUSTER STACK 296-u-11 AIR FLOPITEST DATA SHEETS
APPENDIX M, 241-sY TANK EXHAUSTER STACK 296-s-25 AIR FLOW TEST DATA SHEETS
AppENDIX ii,241+2-702 BUILDIWG EKHAUST STACK 296-A-43 AIR FLOW TEST DRTA
AppENDIX 0, 24I-AY/AZ TANK EXWAUST STACK 296-A-42 FUR FLOW TEST DATA SHEET
ApPENDIX p, 241-c 106 TANK EKWJSTER STACX 296-c-6 AIR FLOW TEST DATA SHEE
AppENDIX Q, 500 CM pORTABLE EXSAUSTER 296-P-4I FUR FLOW TEST DATA SHEETS
APPENDIx S, COKE SPMPLING EXHAUSTER 296-P-33 AIR FLOW TEST DATA SHEET
APPENDIx T, COKE $AMPLING EXXAUSTER 296-P-34 AIR FLOW TEST DATA SHEET
APPENDIX U, 1000 CM PORTRELE EXHAUSTERS POR-007-SKID E G POR-OOS-SKID F A
241-AN K1-5-1 TANK EXHAUSTER 296-A-29 HEPA FILTER AEROSOL
APPENDIX AA, 241-P,NTANK FARM ANNULUS INLET FILTER AEROSOL TEST DATA SHEET
APPENDIX AB, 241-AN EF-103 ANNULUS EXHAUSTER 296-A-30 HEPA FILTER AEROSOL
APPENDIX AC, 241-AN EF-104 ANNULUS EXHAUSTER 296-A-30 HEPA FILTER AEROSOL
APPENDIX AD, 241-AP TANK FARM HLUS INLET FILTER R2ROSOL TEST DATA SHEET
APPENDIx AE, 241-AP K2-5-1 ANNULUS EXHAUSTER HEPA FILTER AEROSOL TEST DATA
RELEAsE DATE STATUS
2/23/98
4/2’7/98
12/23/91
12/23/97
1/05/9s
1/06/98
1/05/98
12/29/97
12/30/97
1/05/98
12/30/97
1/01/98
1/20/98
5/18/98
1/07/98
7/17/98
1/05/98
7/09/98
10/02/91
6/12/97
2/23/98
6/12/97
3/04/98
12/04/97
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
AcT1V2
ACT1VE
ACTIVE
ACTIVE
HNF-34.1O,Rev. O
22
-.- —————---- -------7/27/90
_-.—-------
Master Index of Active and Developing‘LankFarm operating and Maintenance Procedures
Page 15
------ -----
PROCEDURE NUNBER REV---------------- ---6-TF-156AF
6-TF-156AG
6-TF-156AH
6-TF-156AI
6-TF-156AJ
6-TF-156AK
6-TF-I56AL
6-TF-156PM
6-TF-156AN
6-TF-156B
6-TF-156DA
6-TF-156DB
6-TF-156Dc
6-TF-156DD
6-TF-156DE
6-TF-156DF
6-TF-156CG
6-TF-156DH
6-TF-156D1
6-TF-156DJ
6-TF-156FA
6-TF-156FB
6-TF-156FC
6-TF-156FH
0
0
0
0
0
0
0
0
0
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
REV# PRCCEDUKE TITLE--- --------------------------------------------------------------------------E APPENDIX AF, 241-AP K2-5-2 ANNDLUS E~AUSTER HEPA FILTER AEROSOL TEST DATA
A APPENDIX AG, 241-AW TANK FARM RNNULUS INLET FILTER AEROSOL TEST DATA SHEET
R APPENDIX AH, 241-Aw K2-5-1 ANNULUS EXXAUSTER 296-A-28 HEPA FILTER AEROSOL
A APPENDIX AI, 241-AW K2-5-2 ANNULUS EXKAUSTER 296-A-28 HEPA FILTER AEROSOL
s APPENDIx AJ, 241-AY 101 ANNULUS EXSAUSTER 296-A-18 HEPA FILTER AEROSOL TES
D APPENDIX AK, 24I-AY 102 ANNULUS EXSAUSTER 296-A-19 HEPA FILTER AREOSOL TES
A APPENDIX AL, 241+2 ANNNLUS E~usTER 296-A-20 HE pA FILTER AEROSOL TEST DA
B APPENDIX A34,241-sY TRNK FASM ANNDLUS INLET FILTER AEROSOL TEST DATA SHEET
0 APPENDIX AN, 241-sY RNNULUS EXSAUSTER 296-P-22 HEPA FILTER AEROSOL TEST
0 APPENDIX B, 1000 C3M PORTABLE EXKAUSTERS POR-007-SKID E & POR-008-SKID F H
B APPENDIX DA, 244-A WRT INLET FILTER AEROSOL TEST DATA SHEETS
B APPENDIX DB, 244-A EY2RTEXHAUSTER 296-A-25 HEpA FILTER AEROSOL TEST
B APPENDIX DC, 244-BX LX2RTINLET FILTER HEPA FILTER AEROSOL TEST DATA SHEETS
A APPENDIX DD, 244-BX EH3RTEXHAUSTER 296-B-28 HEPA PILTER AEROSOL TEST DATA
A APPENDIX DE, 244-s CCRT INLET FILTER AEROSOL TEST DATA SHEETS
B APPENDIX DF, 244-s CCRT ExHAUSTER 296-s-22 HEPA FILTER AEROSOL TEST DATA s
B APPENDIX DG, 244-TX CCRT INLET FILTER AEROSOL TEST DATA SHEETS
B APPENDIX DH, 244-Tx DCRT 3xsAusTEIl296-T-18 HEPA FILTER A3ROSOL TEST DATA
0 APPENDIX D1, 244-u CCRT INLET FILTER AEROSOL TEST DATA SHEETS
0 APPENDIX DJ, 244-U CCRT EXHAUSTER 296-u-11 HEPA FILTER AREOSOL TEST DATA S
A APPENDIX FA, 204-AR LORD OUT RCC84EXKAUSTER 296-A-26 HEpA FILTER AEROSOL T
A APPENDIX FB, 204-AR CATCH TAWK E~AUSTER 296-A-26 HEPA FILTER AEROSOL TEST
B APPENDIX Fc, 209-E CELL & BUILDING EXKAUSTER 296-P-31 HEPA FILTER AEROSOL
c APPENDIX FH, 242-s HOT CELL EmUSTER 296-s-18 HEpA FILTER AEROSOL TEST DA
HNF-341O, Rev. O
23
RELEA3E DATE---------3/06/98
4/27/98
4/27/98
4/27/98
3/06/98
2/23/98
7/31/95
5130/91
3/30/95
7/09/98
10/14/97
10/14/97
6/23/97
6/23/91
10/16/91
10/27/91
10/16/91
9/26/91
8/31/95
8/31/95
6/23/91
6/23/97
12/23/91
6/12/91
STATUS--.-_-_._-
AcTIVF.
AcT1v2
ACT1V2
ACTIVE
ACTIVE
ACT1V3
ACTIVE
AcTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
ACT1V2
AcTIVE
AcT1V2
ACTIVE
ACTIVE
-===========..==============.====----- ===========_----=================_____----- -—___ _——-7/27/98
.======.====_..-___-—_____---—__------.=====.====______=======_-.——-- _-_-e=.======Master Index of Active and Developing Page 16
Tank Farm Gperating and Maintenance Procedures_.———________ ----- .-.—--—————-—----—————------
PROcEDUffimER ffiv REv# PRCCEDURE TITLE---------------- --- --- --------------------------------------------------------------------------6-TF-156FI
6-TF-156FK
6-TF-156FL
6-TF-156~
6-TF-156F0
6-TF-1563W
6-TF-156PB
.6-TF-156Pc
6-TF-156TB
6-TF-156Tc
6-TF-156TD
6-TF-156TE
6-TF-156TF
6-TF-156TG
6-TF-156TH
6-TF-156T1
6-TF-156TJ
6-TF-156TK
6-TF-156TL
6-TF-156~
6-TF-156TN
6-TF-156T0
6-TF-156TP
6-TF-156TQ
0
0
0
P.
A
o
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A APPENDIX F1,
A APPENDIX FK,
A APPENDIX FL,
1 APPENDIX FN,
o APPENDIX FO,
A APPENDIX 5Wr
0 APPENDIX PB,
A APPENDIX PC,
r! APPENDIX TB,
0 APPENDIX TC,
c APPENDIX TD,
c APPENDIX TE,
E APPENDIX TF,
D APPENDIX TG,
B APPENDIX TH,
B APPENDIX T1,
c APPENDIX TJ,
A APPENDIX TK,
A APPENDIX TL,
A APPENDIx TM,
A APPENDIX TN,
0 APPENDIx TO,
A APPENDIX TP,
A APPENDIX TQ,
242-T BUILDING EXSAUSTER 296-T-17 HEPA FILTER AEROSOL TEST DA
244-CR VAULT EXHAUSTER 296-c-5 HEPA FILTER AEROSOL TEST DATA
244-CR VAULT EXKAUSTER 296-C-5 TOP OVEEALL HEPA FILTER AEROSO
242-Az-702 VENTCELL INLET FILTER AEROSOL TEsT DATA SHEETS
241-Az 702 BUILDING EMAUSTER 296-A-43 AEROSOL TEST DATA SHEE
213-w CCMPACTOR BUILDING EXHAUSTER 296-W-3 HEPA FILTER AEROSO
CORE SANPLING EXHAUSTER 296 -P-33 HEPA FILTER AEROSOL TEST DA
CORE SANPLING EXSAUSTER 296-P-34 HEPA FILTER AEROSOL TEST DAT
241-A-702 zrflA2T7d4KE~usTER 296-A-II REpA FILTER xROSOL T
241-A-702 AYIAZ BAcKUP EXSAUSTER 296-P-26 HEPA FILTER AEROSOL
241-AN EF-101 TANK EXHAUSTER 296-A-29 HEPA FILTER AEROSOL TES
241-AN EF-102 TANK EXHAUSTER 296-A-29 HEPA FILTER AEROSOL TES
241-AP K1-5-1 TANK EXKAUSTER 296-A-40 HEPA FILTER AEROSOL TES
241-AP K1-5-2 TANK EXXAUSTER 296-A-40 HEPA FILTER AEROSOL TES
241-Aw K1-5-1 TANK EXHAUSTER 296-A-27 HEPA FILTER AEROSOL TES
241-Aw K1-5-2 TANK E~AusTER 296-A-27 HEPA FILTER AEROSOL TES
241-c 105/106 TANK INLET FILTER AEROSOL TEST DATA SHEETS
241-c 105/106 TANK EXHAUSTER 296-p-16 HEPA FILTER AEROSOL TES
241-sx TANK INLET FILTER AEROSOL TEST DATA SHEETS
241-sx TANK EXHAUSTER 296-S-15 HEPA FILTER A810soL TEST
241-sY TM lNLET FILTER AEROSOL TEST DATA SHEETS
241-sY TANK EXH?OJSTER 296-P-23 HEPA FILTER AEROSOL TEST
241-sY BACKUP TANK EXHAUSTER 296-P-28 HEPA FILTER AEROSOL TES
241-SY TANK EXKAUSTER 296-s-25 HEPA FILTER AEROSOL TEST DATA
RELEASE DATE---.-_-_-6/24/97
6/24/91
7/08/97
2/25/98
10/16/91
6/12/97
7/11/98
1/05/98
6/24/91
1/18/95
2/23/98
2123198
11/25/97
3/04/98
5/08/98
5/08/98
5/14/98
5130/97
4/18/97
7/01/91
6/03/97
1/19/95
10/02/95
10/02/95
STATUS----------ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V3
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
ACTIVE.
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
HNF-341O, Rev. O
24
-————--_--=., . -————-——— ___________.= . _________________________________________________- ._7/27/90 Master Index of Active and Developing Page 17
‘LankFarm Operatinq and Maintenance Pm.edures====================================================.=================================____===========---- .==================.==================================
PRCCEDUSX NUNRER REV-.-----.-------- —-.
6-TF-156TR
6-TF-156Ts
6-TF-156TT
6-TF-156TT
6-TF-156TU
6-TF-156Tv
6-TF-156Tw
6-TF-157
6-TF-157A
6-TF-157AX
6-TF-157B
6-TF-157BX
6-TF-157BY
6-TF-157C
6-TF-157Du
6-TF-157Ew
6-TF-157QB
6-TF-157Q2
6-TF-157QT
6-TF-157S
6-TF-157SS
6-TF-157sx
6-TF-151T
6-TF-157Tx
0
A
0
0
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
MV# PRCCEDUFW TITLE--- --------------------------------------------------------------------------0 APPENDIX TR, 241 P.Y/P,z-702TANK INLET FILTER AERosoL TEST DATA SHEETS
1 APPENDIX TS, 241 P.Y/AZTANK INLET EXHAUSTER 296-A-42 AEROSOL TEST DATA SHE
0 APPENDIX TT, 241-C 106 TANK EXHAUSTER 296-c-6 AEROSOL TEST DATA SHEETS
A APPENDIX TT, 241-C 106 TANK EXKAUSTER 296-c-6 AEROSOL TEST DATA SHEETS
0 APPENDIX TU, 500 CF14PORTABLE EXHAUSTER 296-P-41 HEPA FILTER AEROSOL TEST
c APPENDIX TV, 241-AN TANK INLET FILTER AEROSOL TEST DATA SHEETS
B APPENDIX TW, 241-AW TANK INLET FILTER AEROSOL TEST DATA SHEET
E 241-QC TANK FARM BREATHER FILTER AEROSOL TEST DATA SHEETS
D APPENDIX A, 241-A TANK FAEM BEEATHER FILTER AEROSOL TEST DATA SHEETS
D APPENDIX RX, 241-.AXTANK FAEM BREATHER FILTER AERoSOL TEST DATA SHEETS
c APPENDIX B, 241-B TRNK FAFC4BREATHER AEROSOL TEST DATA SHEETS
c APPENDIX BX, 241-Bx TANK FARN BREATHER FILTER AEROSOL TEST DATA SHEETS
D APPENDIX BY, 241-BY TANK FAFJ4BREATHER FILTER A3ROSOL TEST DATA SHEETS
F APPENDIX C, 241-c TANK FARM BREATHER FILTER AEROSOL TEST DATA SHEETS
A APPENDIX DU, 244-U DCRT BFW,ATHER FILTER AEROSOL TEsT DATA SHEETS
B APPENDIX EW, 241-EW-151 CATCH TANK BREATHER FILTER AEROSOL TEST DATA SHEET
B APPENDIX QB, 241-BX-101 BEEATHER FILTER AEROSOL TEST DATA SHEET
E APPENDIX CC, 241-C 103 BBE?.THER FILTER AEROSOL TEsT DATA SHEETS
B APPENDIX QT, 241-TX-113 BFC?,ATHERFILTER AEROSOL TEST DATA SHEETS
c APPENDIX S, 241-s TANK FARM BREATHER FILTER AEROSOL TEST DATA SHEETS
c APPENDIX SS, 241-S-304 CATCH TANK BREATHER FILTER AEROSOL TEST DATA SHEETS
B APPENDIX SX, 241-sx TANK FARM BRSATHER FILTER AEROSOL TEST DATA SHEETS
c APPENDIX T, 241-T TANK FARM BREATHER FILTER AEROSOL TEST DATA SHEETS
c APPENDIX TX, 241-Tx TANK FARM BREATHER FILTER XROSOL TEST DATA SHEETS
HNF-341O, Rev. O
25
RELEASE DATE---------10/26/97
10/27/97
B/20/96
5/28/98
7/30/91
7/14/90
5/14/9B
10/23/97
2/23/9B
10/2B/97
10/27/97
10/27/97
10/23/97
2/25/98
1/04/96
5/30/97
9/26/91
12/22/97
10/20/91
10/16/97
6/30/97
10/23/97
10/20/97
1/13/98
STATUS__________
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
AcT1v2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
7/27/98
.—___ .---—-. .---———_____ ------
Master Index of Active and Developing Page 18Tank Farm Cperating and Maintenance Procedures
------.-.——.—.—.—.—.—.—-..——.-—-—-.---— -----
PRCCEDURS NUMEER R2V S.EV#PRCCEDUAB TITLE RE1,E!ASPnAT17 ST,.,,*
6-TF-157TY
6-TF-157u
6-TF-157VA
6-TF-157VV
6-TF-157W
6-TF-158
6-TF-158Fx4
6-TF-158c
6-TF-158sx
6-TF-158sx
6-TF-158sY
6-TF-160
---0
0
A
A
0
0
0
0
0
B
o
1
---------- -------------------------------------------------------------------------- ----------. .. -. ..-----------B
B
0
0
A
D
c
c
B
0
B
F
6-TF-182
6-TF-183
6-TF-191
6-TF-192
6-TF-197
6-TF-198
6-TF-200
6-TF-201
6-TF-202
6-TF-203
A 0
0 0
Oc
0 0
OA
0 0
0 0
0 0
0 0
0 0
241-TY TANK FASM BREATHER FILTER AEROSOL TEST DATA SKEETS
ApPENDIX u, 241-u TANK FAF24BR2ATHER FILTER AEROsOL TEST DATA SHEETS
APPENDIX VA, 6241-A CROSS SITE FACILITY BREATHER FILTER R2ROSOL TEST DATA
APPENDIX W, 6241-V CROSS SITE FACILITY BREATHER FILTER AEROSOL TEST DATA
APPENDIX W, 213-w F.ETENTION TANK BRY,ATHER FILTER AEROSOL TEST DATA SHEETS
241-SY WASTE TANK AIR FLOW NEASUREf4ENT DATA SHEETS
APPENDIX AN, 241-RN WASTE TANK AIR FLOW lCi.ASUmNT DATA SHEETS
APPENDIX c, 24l-c 105/106 WAETE TANK AIR FLOw mA.3usm4sNT DATA SHEETS
APPENDIX SX, 241-SX WASTE TANK AIR FLOW lfiASUR2NENT DATA SHEETS
APPENDIX SX, 241-SX WASTE TANK AIR FLOW MEASURENSNT DATA SHEETS
APPENDIX .sf,241-sy ~STE TANK mR FLOw t.13A5uftk2-i2NTDATA SHEETS
Static Bonding for Portable Equipment
9/30/97
9/30/97
3/06/98
3/06/98
12/07/95
10/23/91
4/22/91
4/22/91
4/15/97
4/22/97
11/13/97
ACTIVE
ACTIVE
ACTIVE
AcT1v2
ACTIVE
ACTIVE
ACTIVE
ACTIVS
ACTIVE
NVISING
AcT1V2
ACT1V2
EBERLINE AMS-4 CONTINUOUS AIR MONITOR CAL1BRATION 10/31/ 97 ACTIV2:s;w:~mm??%$?
REVISING
GAST OIL-LESS VACUUN PUMPS DEVELOPING
ELECTRIC TACHC+4ETERGENESATOR, Ml200-HRST DR1LL HEAD PEWETRATION SATE CAL 5/03/95-wwA&I~xw%41.~
ACTIVE....M:$-~
Generic Thermocouple Test Procedure
General Electric circuit Breaker Type AX-50/75/100
2704-~ EMERGENCY LIGHTS INSPECTION
DRYWELL VAN PROBE CONNECTORS
MCOSE INDUSTRIES MODEL ALX D1R2CT CUSRENT
244-AR VAULT CSANE, ELECT
1000 CF14PORTABLE EXHAUSTER (296-P-2s ) PREV2NT1VE NAINTENANcE
4/20ma Repeater Power supply check
6/05/98 ACTIVE
S/26/94 ACTIVS
1/30/ 97 ACTIVE
DEVELOPING
10/26/ 95 ACT1V2
DEVIiLOPING
& SUNCTIONAL DEVELOPING
10/26/95 P.CT1V2
HNF-341O. Rev. O
26
----- -------- ---------------1/21/90 l.laste,Index of Active and Developing Page 19
Tank Farm Gperating and Maintenance Procedures—.-.-.---—------------ -_--—_—_-_----_——————————————————_—__----------- -— ---- .--_---_————_
PRCCEDURS NVNSER REV SXV# PRCCEDURX TITLE ~LERSE DATE__-.—----------- --- --- -------------------------------------------------------------------------- ---------
6-TF-204 0
6-TF-205 0
6-TF-206 0
6-TF-208 0
6-TF-209 0
6-TF-21o 0
6-TF-212 0
6-TF-213 0
6-TF-214 0
6-TF-215 0
6-TF-216 0
6-TF-219 0
6-TF-220 1
6-TF-221 2
6-TF-225 0
6-TF-227 0
6-TF-228 0
6-TF-233 0
6-TF-237 1
6-TF-239 0
6-TF-240 o
6-TF-241 0
6-TF-242 0
6-TF-243 0
0
0
0
0
0
0
B
A
c
B
D
0
A
D
0
0
A
0
F
0
0
0
A
B
1NSPECTION OF EI.5RGENCY LIGHTS TANK FASMS
MXRCOID PRESSURE CONTROL WITCH CAL1BFATION 1NsTRUCTIONS 8/17/95
CR3S POWF.SBLCCPOWER COND1TION1NG, 2750E
mCTIONAL TEST OF CASS Amw4s FOR POWER CONDITIONING SYSTEN - 2750E BUILD
lNSP AND t4A1NTOF 252-S SWITCHGEAR BATTERIES (TYPE H34P )
Onan Diesel Generator
GM D,lco Diesel Generator 300 W’+lnSPection & ~eraticm
caterpillar Diesel Generator 500 KW Inspection & Gperati.n
iii-Case Diesel Generator 110 KW Inspection & Gperation
241-A-701 300Hw GM-Delco Standby Diesel Generator Cold Automatic Start, ln
lL1-CA3E 110 SW STRNDBY DIESEL GENERATOR ATS 1NsPEcTIoN & SERVICE
Inspection of Cathodic Protection system Rectifier.s
1NSPECTION OF EAST TANK FARM TRPNSFORMXRS
MANUAL TEMPERATURE READINGS FOR WEST AREA TPNK FARMS
Baltimore Cooling Tower Maintenance
OpERATING LOAD CHECK 6 TIfEF.3.tALHEATING SURVEY OF THE 241-AP AREA DISTRIBUT
sUPPLY AND EXSAUST FAN 1NSPECTION
CAL OF lSA-34FU+LCARSON MONOXIDE (co) MONITOR
BELCO INSPECTION
PORTASLE ELECTRIC TCOLS INSPECTION
Digital Panel Meter Calibration Instructions
7/23/ 98
10/16/95
3/05/98
3/05/98
7/23/ 98
10/26/94
10/16/95
5/2S/97
3/19/97
10/29/97
3/28/96
4/05/96
3/19/97
3/19/91
STATUS
DEVELOPING
ACTIVE
DEVELOPING
DEVELOPING
DEVELOPING
DEV2LOP1NG
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVK
ACTIVE
ACTIVE
DEVELOPING
DEVELOPING
AcT1v2
DEVELOPING
ACTIVE
ACTIV3
ACTIVE
DEVELOPING
ACTIVE
ACTIVE
HNF-341O, Rev. O
27
--—-------.= ~===================.=====___-.__--_-_-_-_—---————————_____=======.=====.==____________________________________________====________7/27/98 Master Index of Active and Developing Page 20
Tank Farm Gperating and Maintenance Procedures.=.=-=========_..._._._._=..__..._._.=======================-----------= ====================.=____=================================_____==..--.-_________..=----------- ----------- --_-_-_--— ---- -----
PNx2EDURX NWNEE.R ESV REV# PRCCEDUKE TITLE RELEASE DATE STATUS---------------- --- ---*;=*%MMWW?*%2Z4
$J~>~<=g@g%mm$
6-TF-247 B 0
6-TF-248 OA
6-TF-250 1 0
6-TF-253 0 0
6-TF-254 0 0
6-TF-255 0 0
6-TF-256 0 0
wwmwixfw:E%:ww3w*w
6-TF-301 0 0
6-TF-304 OA
6-TF-309 0 0
6-TF-310 0 0
6-TF-332 OB
6-TF-333 0 0
6-TF-334 0 0
6-TF-336 OB
6-TF-340 0 0
6-TF-344 0 0
6-TF-345 0 A
6-TF-346 OA
6-TF-347 OA
6-TF-348 OA
__________________________________________________________________________--------- ----------17A & 17B MIT THEFO.KXOUPLES 3/05/98 ACTIVEw%w:~*sw&Hfimm:%P%H>-a%$2mGmxw?mqF%,%~*P%m&%mr*MAY/AZ ELITE FLOW TRAN3M1TTER STARTUP%w~~gwf.m~:wa%wzw+mm+%m~m;~
ACTIVF.:.. .:q:g;#33w
AY/AZ lNDELAC VALVE ALIGN&UINTAND CAL1BRATION ACTIVE
LIMITORQUE MODEL NQ120- 60 ACTUATORm%%%;m~?~AY/AZ cooling Tower Fisher Porter Vortex -~ ..
6/25/98
8/21/96
1NSPECTION & MAINTENANCE OF THE 242-s EWITCHGEAR
Lv SwGR BMERS, SERIES TYPE RL G RLE 1NSPECTION AND NAINTENANCE
centerline OUTTERFLY VALVE INSPECTION AND LUBRICATION
pORTAsLE E~USTER D/P INSTRUMENT LCOP CALIBRATION
Fischer Porter 5ODP41OO Pressure Transmitter
AcTIQ+ lNsTRu~NT, SERIES AP ALARM MODULES, AP108O, AP109O CAL1BFATION PRO
T~spAK x TwO-wlRE TRANENITTER MODEL T703 CAL1BRATION
V2NT1LATION & CCOLING STANDBY GEN MONTHLY PREV W41NT
V2NT1LATION & CCOLING STANDBY GEN ANNUAL PREV MAINT
VENT1LATION & CCOLING STANDBY GEN TRIENNIAL PRS.VNAINT
AY/A2 CENTURA VALVE ALIGNMENT & SERVO CAL1BSATION
1NTERNATIONAL POWER MACHINES MODEL 1PB+1O UPS BATTERY MAINT
lnqersoll-Rand ESV-NL Oil-Free Air compressor Inspection
Ingersoll-Rand ESV-NL Oil-Free Air compressor Maintenance
General Electric Power Circuit Breaker Type AK-2-15 and AK-2/3-25
Adjustment of Cathodic Protection Recti fi,, TaP Settings
General Electric Power Circuit Breaker Type AK4-30/50 and AKK’I’-5O
3/23/96
12/10196
12/10/96
4/23/90
4/22/96
4/22/96
4/28/98
4/17/96
8/09194
12/10/96
3/06/98
3/12/97
3/06/98
ACTIVF
ACTIVE
DEVELOPING
DEVELOPING
DEVELOPING
DEW LOPING
ACT1V2
AcTIVE
AcTIVE
ACTIVE
AcT1n
ACT1V2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcTIVE
HNF-3410, Rev. o
--————.===. ,——————-——————_______________ ______=______________________ _________ ___ _--_-_-_—----7/27/98 Master Index of Active and Developing
Tank Farm Gperatinq and Maintenance ProceduresPage 21
--------------- ---- _--— ------
PRCCEDUS3 Nw4EER XEV REV# PRccEDUXE TITLE RELEAsE DATE STATUS
6-TF-351 0 A
6-TF-352 0 A
6-TF-353 0 A
6-TF-357 2G
6-TF-357ET Oc
6-TF-357LB 0 0
6-TF-357MT OA
w.w.ww+w.mxxfi%~fzw%
6-TF-365 0
6-TF-366 0
6-TF-367 0
6:TF-371 0
6-TF-379 0
6-TF-380 0
6-TF-381 0
6-TF-382 0
6-TF-387 0
6-TF-388 0
6-TF-390 0
6-TP:391 0
6-TF-396 0
6-TF-397 0
6-TF-390 0
0
A
A
B
A
A
B
A
0
0
A
0
0
0
A
-------------------------------------------------------------------------- --------- ----------Br.el h Kjaer Multi-Gas Monitor Type 1302 Functional Check for 3MCS Exhaus. . 3/11/ 98~iwMw;~~%~ . zwm2%w.wmierier’ilElectric Power Ci.CUii Breaker T~e AKR-75I1OO and RXS-50 3/09/98
RBB LOW Voltage Power circuit Breaker Type K-225 through K-2000 and K-600s 3/09/98
EVAPORATIVE CCeLER WINTERIZATION/DEWINTERIZATION FOR 200 2R2T .w.m TANK FA 3/11/98
Testing of Cathodic Protection System 2/19/98
CATHODIC PROTECTION SYSTEM TEsTING EAST TANK FRRMs (ET) 11/03/97
cATnOmc pROTECTION swT2t4 TESTING 222-s L7+608AT0RIEs Im j 11/07/96
cATnOmc PROTECTION SYSTM TESTING w3sT TANK FARh23 (m) 11/07/96
ROSEMOUNT MODEL 3051c D1FF2XENT1AL AND GAUGE PSESSUFC?.TRANSMITTER CRL USIN
M%m-&m_MM3Y~~.M~mi@2mmF:g; ::Foxboro E69F Current-to-Pneumatic signal converter
Encon Portable Eyewash Stations, Inspection/Maintenance 9/16/96
CUSTCM POWER INC. MODEL 12O-1OKNT UNINTERRUPTABLE POWER SYSTEM BATTERY CHE 3/11/ 9S
MODICON B875-101 AND B875-102 HIGH SPEED - INPUT MODULE CAL1BFLATION 3/11/98
241-SY-101 MIXER PmP MOTOR WINDINGS TENP L@3P CAL CHECKS 3/11/98~2m=.w.w~.M:a~%3$wm@xKP3241-sY-101 MIT TANK m PRESSURE RISER 17B LCOP CAL CHECK 3/11/98~w~-ww;wxi~w?mwlm%mn241-SY-101 MIT TANK CC14EPF.ISSUXERISER 17C L~P .C+ CHECK 3/12/9Sm2@:mw_w@mAmam$@~MIXER PUNP COLUNN GA3 PXESSURl LCx3PCAL1BXATION CHi~%” ““””
~M@m~m-Ym@:*x@~wi3/12/ 9S
Z4~-SY-101 M1T7VbTT kVENS STSAIN AVENS F1LTER CAL CHECK 10/16/95
241-SY-101 MIT/VDTT CALEX RMPLIFIER CRL CHECK 10/16/95
3/12/98
9/14/95
10/16/95
10/16/95
3/12/ 98
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcT1V2
ACTIV2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcTIVE
HNF-341O, Rev. O
29
__________.=. .-_---_-——_————___-_——————______ ____________________________ ______------1/27/98
..-_——————————
Master Index of Active and Developing Page 22Tank Farm Operating and Maintenance Procedures
—_—_______ —-—_____ --------- ---_———
PRCCEDURE NUf4EER REV________________ ___
6-TF-400 0
6-TF-401 0
6-TF-403 0
6-TF-405 0
6-TF-406 0
6-TP-406 1
6-TF-412 0
6-TF-413 0
6-TF-414 0
6-TF-417 0
6-TF-423 0
6-TS-424 0
6-TF-426 o
6-TF-427 o
6-TF-429 0
6-TF-431 0
6-TF-432 0
6-TF-433 o
6-TF-434 1
6-TF-435 0
6-TF-436 0
6-TF-437 ,0
6-TF-438 0
6-TF-439 o
0
0
0
0
0
P
0
0
0
0
0
B
0
0
0
0
B
0
A
0
0
0
B
0
R2W PRCCEDURE TITLE R2LEAsE DATE--- -------------------------------------------------------------------------- _________
241-sy-101 WNT HE~ER ~IDITY LOOp cAL CHECK 10/09/95WWWWX*W*WM=:W-W$MW>=:M241-SY-101 VENT HEADER T2NPERATURE LCOP CAL CHECK 10/09/95
T*.wm-Mww~=:w#xm%ammATLAS COPCO CCNPRESSED AIR STATION MAINTENANcE 7/24/95
241-SY-101 MIT & vDTT SIGNAL STRAIN PRCCESSOR CAL CHECK 10/16/97
we-E#*R%mw.-mmF&”3mYM.mw3241-sY-101 VDTT STRAIN LCOP CAL CHECK 10/16/95
-i--3wi$M-l--#z?miM}#m&&fxwR1TTAK2R MODEL 114DO36-10 HYDRo.7ENCELL WITH NEWPORT INFINITY ELECTRONICS 6/17/98Fmm@&Am@%~.~~.@$%241-SY-101 T2t4P/PRESSURS INDICATING TRAN2M1TTER NEWPORT MoDEL Q2000 SERIES 9/19/95
241-SY-101 DACS UPS RELAY LCOP CAL1BRATIONS 10/16/95gm~xa$p%m=;:-.maw%mx%%m%z$241-syT101 THR2E cifAt4iiELRECORDER CHESSELL MODEL 345 CALIBRATION CHECK
w~am-s.@m@mfw$w@.%ETmmm.-im;@#241-sy-lol E0x20R0 D1F~R3NTIAL PF.2ssum TRANSMITTERS CALIBRATION CHECK
M1X2R PUNP DISCHARGE NOZZLE TAP PRESSURE LCOP CAL CHECKSTm*w!am:*@;.&~m$wwm#$z$w$rm6gm&MIXER PUMP VOLUTE PRESSURE LcOP CAL CHECKS@$?m@~.mwm~$?%’.wm3Kc3%FUNCTIONAL TESTING OF PRESSURF RELIEF VALV2S
9/21/95
3/13/98
11/17/95
F2NWPL MODEL 54 TEMPERATUIW CONTROLLER TC1 & Tc2 lD/26/95
A3HCROFT XLDP, ELECTRCNIC DIFFERENTIAL P3ESSUR2 CAL 10/26/95
DIFFERENTIAL PRESSURE LCCJPVER1F1CATION 10/26/95
-RA/LIGHT A2S2MBLY lNSTALLAT1ON/RENOVAL FOR 241-SY-101 RISER 5A NULT1-P 4/11/96
D1FFER2NT1AL TEMPERATURE LOOP VER1F1CATION 10/26/95
241-SY-101 RISER 17B WHITAKER MODEL 114L!O38-10RYDRCGEN CELL WITH NEWPORTgm&~w~m:~:*:@wm&@wlw%m~w, %%&241-SY NITRCGEN DISTR1BUTION CABINET LOW PRESSURI ALARM %%’T95
High Sheath Temp .$witchCalibration 9/21/95
M1X2R PUMP MOTOR WINDINGS 1NSULATION RESISTANCE CHECKS 1/18/96
,.llloV,lOf gaskets & V~lV, packing Containing asbestos 3/13/98
wEST 400 & 800 SERIES TEMPERATURE CONTROLLER CALIBi7AT10NlNSTRUCTIONS 9/18/95
STATUS----------ACTIVE
ACT1V2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIUE
ACT1V2
ACTIVE
ACT1V2
ACTIVE
ACTIUF
ACTIVF.
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcT1v2
ACTIVE
ACTIUE
ACTIVE
ACTIVE
HNF-341O, Rev. O
30
.———_____——— ---_-——————----- _---_———___.————————=.======.===________=========____==s===____========.=..=__________7/27/98
-------- ---- ----Master Index of Active and Developing
Tank Farm operating and Maintenance ProceduresPage 23
========.==========—————.======——————==.=.——————==========.===================_____=.======_____====_________=== .========.=======.=========s=====____===== ==_____ _---— ------- ----- ----- --------- ----
PRCCECURI NUNBER Sf.V REV# PROCEDURE TITLE---------------- --- ---
~LEASE DATE STATUS
s~~*~:~~~.&~*j~~ '------------------------------------------------------------------------- -;;;;j;;-whitaker model 114d038-10 hydrogen cell with ne~ort infinity electronics__________
w%~;~iwxww?mw;%wjmw.w~m:ACTIVE
6-TF-441 1 A MCW.E IND. TCW STD THEFJ.fC.20UPLEALARN h CONTROLLER CALIBRATION 1/29/96 ACTIVE
6-TF-443 0 A
6-TF-444 0 0
KTm%?%%%?mww;*yxm
6-TF-455 0
6-TF-498 1
6-TF-500 0
6-TF-501
6-TF-507 0
6-TF-509 1
6-TF-510 0
6-TF-511 1
6-TF-512 0
6-TF-513 1
6-TF-514 1
6-TF-515 o
6-TF-516 0
6-TF-516 1
6-TF-523 B
6-TF-525 B
6-TF-526 B
6-TF-528 B
6-TF-529 B
0
0
A
E
A
B
A
A
0
0
0
0
0
0
0
0
0
0
PURGING lNSTRUNENT DCRT DIP TUBES FOR 244-Bx 10/31/97 ACTIVE
MIXER PVMP 01L CHANGEOUT 2/06/96 ACTIVE
NRC MONITOR BATTERY CHARGER FIELD PRCGSP1.f-ilNG& MANUAL EQUALIZER lNST. .. .
~mm”a.mw:mwmw:.=m;~Ci<;;;itBreaker Inspection
.:w&g*mgrg@w@Fa#%Y@
KOBELCO BREATHING ,JUR COMPRESSOR PM
ACTION lNST SERIES AP ALARN MOD CAL-~~~CAL lRD MECHANALYSIS 5806 AMPLIFIER
Eberline Beta Air Monitor Models AMS-3 , .W4S-3?.,AMS-3A-1 and 700300=w~.w%-m<a:%z-iw-?.%>m~PRlSSDR2 AND VACUUM GAUGES CAL1BFATION
AIR ROTCf.fETER
DWTER MAGNEHELIC D1FF2RENT1AL PRF.SSUR3SERIES 2000 AND CAPSAHELIC DIFFEREN
T-HL-1, ET-0600 & Love Limit ccmt 48, 49 & 50~qmmDifferential Pressure Transmitter Series 13, 13A, 13H h 15
@@~*:mg*es 3000 G Capeu-Phot.helic series 43000 Diff Switch
vm~40 Millivolt converters
wg3
1 753
BAILEY 7000 VOLTAGE TO FREQUENCY CONVERTER MODEL 74I CALIBRATION pRCCEDU~
ACRC14AGSERIES 800 PNEuNATIC CONVERTER CAL1BWTION PROCEDURE
ROBERTSHRW MODEL 443 R4JD 445 ELECTRO-PNEUIi4T1C CONVERTER CALIBRATION PRCCE
ACTION MODELS 7300 AMD 7500 CD-TO FREQUENCY CONVERTER mLIBSATION PRWEDUR
ACTION MODEL AP4440 sERIES NATHCNATICAL RcOT EXTRACTOR
HNF-341O, Rev. O
31
4/02/96 ACTIVE
10/01/96 ACTIV2
T8ANSFERED
3/16/98 ACTIVE
9/15/97 ACTIVE
3/16/98 ACTIUE
9/15/97 ACTIVR
3/17/98 ACTIVE
6/11/97 ACTIVE
6/11/97 ACT1V2
8/21/96 ACTIVE
8/21/96 ACTIVE
RBV1SING
~VlSING
R3VISING
R3VISING
R3VISING
REVISING
-——————————- --------7/21/98
.----——.Haster Index of Active and Developing
Tank Farm Cperating and Maintenance proceduresPage 24
—_——___
PRCCEDU83 40JMEER REV Ev# PRCCEDURE TITLE________________ --- -.._-_-----_-_-.-..-_-_-_-______---_-_-_____-_-__-__--________,------------
RELEA2E DATE STATUS--- _._-—-—-—
6-TF-533 A 2
6-TF-543 B 0
6-TF-549 B 0
6-TF-554 0 0
6-TF-555 0 0
6-VT-159 A 0
6-W-159TA A 2
6-VT-162 B 0
6-VT-162A B 0
6-W-162B B 1
6-vT-162c A 0
6-VT-1 93 c 1
6-VT-199 B 0
6-VT-245 B 0
s*w#%zMw~&Imm2H
Kw#%%g&mm&”@#
6-W-452 0 0
6-VT-454 A 0
6-VTP-128 A 0
7-ASS-264 A 0
1-ASS-265 A o
%-wAw;w#32~wwN
7-MIse-268 AO
AEP-T-059-00001 A 2
BELHAv2N MODEL BAT-FGM-4 & BAT-FGN-4.46 CAL1BRATION PRCCEDUEFmm#~z.*fi*~ ............**..W&~CANBERRA LIN7LCG RATENETER MODULE 1481L CALIBRATION PRCWEDURE
1/20/98 ACTIVE
P.3X1S1NG
HANFORD-BUILT sURVEILLANCE PULSE AMPLIFIER DISCRIMINATOR (PAD) USED IN LEA F.IVISING
FILTER MEDIA AND GAS BOTTLE REPLACEMENT PRCCEDURE BELHAVEN MODEL BAT-FC+M-4 DEVELOPING
CENTERLINE BuTTERFLY VALV2 1NSPECTION AND LUBR1CATION TRANS3WWD
HEGA FILTER IN-PLACE LEAK TEST 10/26/97 ACTIVE
APPENDIx TA, TANK EXXAUSTER HEGA L2AK TEST DATA SHEETS 3/17/98 AcTIVE
ORGANIC VAPOR SAMPLING FOR TPNK FARM EXHAUST STACKS 6/05/98 ACT1V2
APPENDIX A, 500-c3Y6PORTASLE EKHAUSTER STACK 296-P-41 ORGANIC VAPOR SAMPLIw’a%,~
6/05/98.....~?wmf
ACTIVE
APPENDIX B, EXKAUST STACK 296-A-42 ORGRWIC VAP0R SF64PL1NGDATA SHEETS 6/05/98 ACT1V2
APPENDIX C EXSAUST STACK 296-c-06 ORGANIC VAPOR SR1.lPLINGDATA SHEETS DEV2LOP1NG
NASS-TRON FLOW TERN2NITTER CALIBRATION
m:m~m:@wMw&@pm2/09/98 ACTIVZ
Air Monitor Corp Veltmn 500Az Delta P Transmitter Calibration 10/31/97~.$mmmw.%wwmz.%?
ACTIVE
AY/.3ZCLY3L1NGTOWER CONDUCTIVITY CONTROLLER SERVICING AND CAL1BFWTION 10/31/97 ACTIVE
LINEAE 1NTEG8AT1NG TOTALIZER cAL1BRATION MCORE INDUSTRIES MODEL LIT ACTIVEPmaz*?w.$.@ewK$EJM#%w*AY#w;m-m$3m@&EmEBAF&3:&;i;&A~T1mAY/AZ VENTILATION AND C~L:NG m.w WATER BADGER t.iETERAND TRANSMITTER KEVEN 10/31/97
mwig;e:we.wa%gCALIBRATE 4,- 20 MILLIAMP RC SYSTEMS SlGNAL ISOLATOR OR AIR MONITOR CORPOR 10/31/97
=@EmmwM*m;@ACTIVE
CALIBSATE AY/A2 LIMITORQUE”I00N MODUTRONIC CONTROL BOARD 10/31/97mwm~agm~emma$~%~~~k~q
ACT1V2
SIERFW+SERIES 600]640 1NSERTION TYPE NA2S FLOW NCJ.TERALAs34 SETPOINT ADJUST DEW LOPING
ASBESTOS F.EMOVALUTILIZING A GLOV2 BAG DEVELOPING
ENCAPSUmTION OF EXPOSED ASBESTOS (NO ASBESTOS KEMOVED) FOR THE WFORD SI DEVELOPING
..--ticm*fw,m:&{= ~EQNNY WILL SUPPLY TITLE ~p~.wwzw ;
ACTIV2
OPERATE EURCCLEAN UZ 948 HIGH EFFICIENCY PARTIc!DL.ATEAIR FILTEEED VACUUM DEVELOPING
MSPOND TO ALARMS FOR THE CROss SITE TEAWS3-ER LINE SYSTEM 3/30/98 ACTIVE
HNF-341O, Rev. O
32
.———_____.==. ----- ---_--——------ ..==============.========.==================.=.======.=======.=-_______=======7/27/98 Master Index of Active and Developing
------
Page 25Tank Farm Gpexating and Maintenance E’r..edures
------ ------- --------
PRCCEDURI WER REV R2V# PRCCEDUS3 TITLE RELEASE DATE________________ --- --- -------------------------------------------------------------------------- ---------ARP-T-211-00001 A
ARP-T-211-00002 A
ARP-T-211-00003 A
ARP-T-211-00004 A
ARP-T-221-OO1O1 A
ARP-T-221-OO1O1 B
ARP-T-22I-OO1O2 A
ARP-T-221-OO1O2 B
ARP-T-221-OO1O3 A
ARP-T-221-OO1O3 B
ARP-T-221-OO1O4 A
ARP-T-221-OO1O4 B
ARP-T-221-OO1O5 A
ARP-T-221-oO1O5 B
ARP-T-221-OO1O6 A
ARP-T-221-OO1O6 B
ARP-T-221-oO1O7 A
ARP-T-221-00107 B
ARP-T-221-00108 A
ARP-T-221-OO1O8 B
ARP-T-221-O1O1A A
ARP-T-231-OO1O1 B
ARP-T-231-OO1O2 B
ARP-T-231-OO1O3 B
5
7
2
0
6
0
7
0
6
0
6
0
6
0
6
0
6
0
3
0
0
4
6
4
RBspoND TO PANEL 3 ALARM AT 271-A CONTROL BulLDING
RESPOND TO PANEL 4 ALARM AT 271-A CONTROL F3U1LDING
RESPOND TO PANEL 7 ALRRN AT 271-A CONTROL BUILDING
RESPOND TO PANEL 8 ALAR34AT 271-A CONTROL BUILDING
ResPond TO Panel 101 Alam At 271-AN
Respond To Panel 101 Alarms At 211-AN
Respond TO Panel 102 Alarms At 271-AN
Respond To Panel 102 Alarms At 211-AN
Respond TO Panel 103 Alarms At 271-RN!
Respond To Panel 103 Alarms At 271-AN
Respond TCJPanel 104 Alarms At 271-AN
Respond To Panel 104 Alarms At 271-AN
Respond To Panel 105 Alarms At 271-AN
Respond TO Panel 105 Alarms At 271-AN
Respond TO Panel 106 Alarms At 271-AN
Respond T. Panel 106 Alar~ At 271-AN
Respond T. Panel 107 Alarms At 271-AN
ResPor,dTO Panel 101 Alarms At 271-EN
RESPOND TO PANEL1 RNN-108 ALAPJ4SAT 271-AN
RESPOND TO PANEL1 ANN-108 ALARNS AT 211-AN
RESPOND TO PANEL ANN-101A ALARMS AT 271-AN
RESPOND TO PANEL 101 ALARMS AT 271-Aw
R2SPOND TO PANEL RNN-102 ALARMS AT 271-AW
SESPOND TO PANEL 103 ALARMS AT 271-Aw
5/28/9S
5/28/98
9/29/97
4/23/9B
4/24/98
4/27/98
4/27/98
4/27/98
4/21/98
4/24/98
4/27/90
3/04/9s
4/28/98
6/25/9B
4/28/98
STATUS----------
AcTIVE
ACTIVE
ACTIVE
ACTIVB
ACTIVE
REVISING
ACTIVE
3EV1S1NG
ACTIVS
REVISING
ACTIVE
RBV1SING
AcT1v2
9.EVISING
ACTIVE
REVISING
ACTIV2
3EV1S1NG
ACTIVE
SX.V1SING
DEVELOPING
ACT1V3
ACTIVE
ACTIVE
HNF-341fI,Rev. O
33
============.____________________________________________----_----——-—-1/27/98
------
Master Index of Active and DevelopingTank Farm Cperating and Maintenance Procedures
Page 26
-------- -—___________
PRccEDURE NvNBER
ARP-T-231-OO1O4
ARP-T-231-OO1O5
ARP-T-231-OO1O6
ARP-T-231-AUX
ARP-T-251-00003
ARP-T-251-00005
ARP-T-251-00006
ARP-T-251-00007
ARP-T-251-00008
ARP-T-251-00009
ARP-T-251-OOO1O
ARP-T-251-00011
ARP-T-251-00012
ARP-T-251-00013
ARP-T-251-00014
ARP-T-251-00015
ARP-T-251-00016
ARP-T-251-00011
RRP-T-251-00018
RRP-T-251-00019
ARP-T-251-00020
ARP-T-251-00021
ARP-T-251-00022
RRP-T-251-OO023
RXV 3EV# PRCCEDUSE TITLE---
RELEAsE DATE
B 5 R2SPOND TO PRNEL 104 ALARMS AT 271-AW 4/28/98
B4 RRSPOND TO pWEL 105 ALRRNS AT 271-Aw
B4 R3SPOND ’20PANEL 106 ALRRNS AT 271-At4
B 4 RESPOND ‘TOPANEL AIJXRLARf.fSAT 271-AW
B 5 RESPOND TO Mcs GRAPHIC #03 LEAK DETECT MP.RNS
B 4 P.ISPONDTO MONITOR CONTROL SYSTEM GRAPHIC #05 RAW WATER SUPPLY ALAEt-fS
B 5 RESPOND TO MONITOR CONTROL SYSTEM’GRRPHIC #06 F.VAPAYI ALARNS
B 6 REsPOND TO t40N1’foRCONTROL SYSTEN GRRPHIC #01 EVAP AY2 ALARNS
B 6 R3SPOND TO MONITOR CONTROL SYSTEM GRAPHIC #08 EVAP R21 ALARNS
B 6 sRspOND To MONITOR CONTROL SYSTEN GsApnIc #09 EVAP AZ2 ALRRNS
B 3 FaspOND To MONITOR CONTROL SYSTEN GsApnlc #lo RECIRC AYI ALRRNS
B 2 RESPOND TO MONITOR CONTROL SYSTEM GRAPHIC #11 SRCIRC AY2 ALARMS
B 2 R3sp0ND To MONITOR CONTROL SYSTEM GsnpnIc #12 RRCIRC R21 ALRRNS
B 2 wspoND To MONITOR CONTROL SYSTEM Gwpnlc #13 RECIRC R22 ALRRMS
B 3 R2SPOND TO MONITOR CONTROL SYSTEM GRAPHIC #14 CHILLER ALRRNS
B 5 RESPOND TO MONITD,RCONTROL SYSTEM GRAPHIC #15 PRINARY VENT ALP,SMS
B 5 R2SPOND TO MONITOR CONTROL SYSTEM GRAPHIC #16 PRINARY CCOLING ALARMS
B 9 R2SPOND TO MONITOR CONTROL SYSTEM GRAPHIC #11 PRIMARY STACK ALA8MS
B 8 RESPOND TO MONITOR CONTROL SYSTEM GRAPHIC #18 PRINASY VENT STACK ALF!SMS
B 5 P.3SPONDTO MONITOR CONTROL SYSTEM GRAPHIC 1419BUILDING SUPPLY ALRSMS
B 3 RESPOND TO MONITOR CONTROL SYST2N GRAPHIC #2O BUILDING EXHAUST ALRRMS
B 2 SESPOND TO MONITOR CONTROL SYSTEM GRAPHIC #21 BUILDING STACK ALARMS
B 4 RESPOND TO MONITOR CONTROL SYSTEN GRAPHIC f22 B“ILDING VENT CONTROL ALARMS 5/08198
B 2 RESPOND TO MONITOR CONTROL SYS’I’2MGRAPHIc t23 DIESEL GENERATOR ALARMS 12/07/97
4/29/98
4/20/9s
3/03/98
3/16/98
3/10/98
6/09/98
6/09/98
6/09/98
6/09/98
12/07/91
12/07/97
12/07/97
12/07/97
2/25/98
6/04/98
2/26/98
3/17/98
7/02/98
3/09/98
12/07/97
12/08/97
---------.ACTIVE
ACTIVE
AcT1v2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V3
ACT1V2
AcT1v2
ACT1V2
ACTIVS
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACT1V2
HNF-341O, Rev. O
34
----———————-.--------- .====.=================================------ _-_-———7/21/98
----_———
Master Index of Active and Developing—.—.—=.=
Page 27Tank Farm Gperating and Maintenance Procedure
---- --_--_———----- _— ---
PROCEDURE MER EEV AEV# PROCEDURE TITLE---------------- --- --- __________________________________________________________________________
AAP-T-251-00024 B
AAP-T-251-00025 B
ARP-T-251-00026 B
ARP-T-251-00027 B
ARP-T-251-00028 B
ARP-T-251-00029 B
AAP-T-251-00030 B
ARP-T-271-OO1O1 A
ARP-T-271-OO1O2 A
ARP-T-211-OO1O3 A
AAP-T-27I-OO1O4 A
ARP-T-271-OO1O5 A
ARP-T-271-OO1O6 A
ARP-T-271-OO1O7 A
ARP-T-211-OO1O8 A
ARP-T-271-Aux A
ARP-T-271-HvAC A
ARP-T-271-RM A
ARP-T-291-00001 A
ARP-T-301-00001 A
ARP-T-301-00001 B
AAP-T-301-00002 A
ARP-T-301-00002 B
ARP-T-331-00001 A
2
2
3
2
3
2
2
4
4
3
3
3
3
2
3
2
1
3
0
2
0
2
0
1
R2SPOND TO MONITOR CONTROL SYSTEM GRAPHIC #24 RECIRC MACRO ALARMS
RESPOND TO MONITOR CONTROL SYSTEM GRAPHIc #25 MACRO ALARMS
EESPOND TO MONITOR CONTROL SYSTEM GRAPHIC #26 A2START MACRO ALARMS
RESPOND TO 140N1ToRCONTROL SYSTEM GRAPHIC #27 BLIx3MACRO ALARMS
RXSPOND TO MCS GRAPHIC #28 LCU MoNITOR ALARMS
RESPOND TO MONITOR CONTROL SYSTEM POWER SUPPLY ALAFMS
REsPOND TO STF!NDBYDIESEL GENERAToR LCCAL ALARMS
REsPOND TO PANEL 101 ALARMs AT 211-AP
EEsPOND TO PANEL 102 ALARMs AT 271-AP
EESPOND TO PANEL 103 ALARMS AT 271-AP
R3SPOND TO PANEL 104 ALAEMS AT 271-AP
REsPOND TO PANEL 105 ALARMS AT 211-AP
EESPOND TO PANEL 106 ALARMs AT 271-AP
RESPOND TO PANEL 107 ALARMs AT 271-AP
RESPOND TO PANEL 108 ALARMs AT 271-AP
RESPOND TO PANEL AUX ALARMs AT 271-AP
RESPOND TO PPNEL HVAC ALARMs AT 271-AP
RESPOND TO PANEL SM ALARMS AT 271-AP
R3SP0ND TO ALARMS AT 204-AA
RESPOND TO ALARMS AT BX FARMS
R3SPOND TO ALARMS AT BX FARMS
RRSPOND TO ALARMS AT 254-BY
RESPOND TO ALARMS AT 254-BY
RESPOND TO ALAF2.lSAT 241-C CHILLER SKID ALAAN.3
RELEA2E.DATE
12/07/97
12/07/97
12/07/91
12/07/97
3/11/98
12/07/97
12/07/97
4/27/98
4/27/98
4/27/98
4/21/98
4/21/98
4/27/98
4/28/9S
4/28/9S
10/01/91
9/29/97
10/0s/97
9127/97
9/27/97
7/01/98
STATUS----------
ACT1V2
ACT1V2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
AcTIVE
AcT1m
ACTIV2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
DEUELOPING
ACTIVE
~VISING
ACTIVE
REV1SING
ACTIVE
HNF-341O, Rev. O
35
-.-_---——.=. .=======.=================.=====.======.—.—.—-__=====.==____=.,..======.======s=======_________======____===..===============~---- ---------7/27/90
----
Master Index of Active and Developing Page 28Tank Farm Opezatinq and Maintenance Procedures
s===================-------==================__------=========_------=================================.==============______===_____________===_____=========------- -------- ------- ------ ..-—.—------- -----
PRCCEDURE NUMSER RIV R2V# PRCCEDURE TITLE RZLEASE DATE---------------- --- --- -------------------------------------------------------------------------- _________
ARP-T-331-00002
ARP-T-331-OOO03
ARP-T-331-00004
ARP-T-331-00005
ARP-T-331-00006
ARP-T-331-00007
ARP-T-361-00001
ARP-T-431-00001
ARP-T-432-001
ARP-T-432-003
ARP-T-432-004
ARP-T-432-005
ARP-T-432-006
AXP-T-432-007
ARP-T-432-O1O
ARP-T-432-011
ARP-T-432-012
ARP-T-432-014
ARP-T-432-015
ARP-T-432-016
ARP-T-432-011
ARP-T-432-019
ARP-T-432-020
ARP-T-432-021
A
A
A
A
A
A
c
A
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
2
3
0
1
3
2
0
0
0
1
0
3
0
0
0
0
0
0
0
0
0
0
0
0
R4SPOND TO ALRR34sAT 241-C ELECTRICAL SKID
RESPOND TO ALARMS AT MO-211 WRSS cONTROL RCC+4
RESPOND TO ALARMS AT SERVICE BUILDING 241-c-73
wspOND To ALARMS AT ELECTRICAL EQUIPMENT SKID 241-AY-51
RESPOND TO ALARMS AT pRCCESS CONTROL BUILDING 241-c-91
RRSPOND TO WRSS DATA ACQUIS1TION SYSTEM CCMPUTER ALARMS
RESPOND TO ALARMS AT 271-cR
RESPOND TO LOW NITRCGEN PRESSUP.2ALARN SY-FAsM
H2 CONCENTRATION HIGH
TANK DC+C3PRESSURE HIGH
vENT HEADER FLOW HIGH
MIT COLUMN STRAIN HIGH
VDTT COLUMN STRAIN HIGH
PUMP COLUMN STRAIN HIGH
WASTE TEMP HIGH
VENT HEADER FLDW LOW
PUMP MOTOR SPEED HIGH
PUMP MDTOR CURRENT HIGH
PUMP MOTOR OIL TEMPERATURE HIGH
PUMP COLUMN GAS PRESSUR2 LOW
M01STDR2 IN PUMP MQTOR OIL HIGH
DUAL PLC FAILURE
STATION 5 CCMPUTER LOCKUP OR CRASH
sTATION 8 CCMPUTER LOCKUP OR CRASH
1/21/90
7/11/98
5/05/98
7/01/98
7/21/98
1/27/98
9/22/97
6/25/97
6/11/97
2/28/98
5/30/97
7/18/97
5/30/97
5/30/97
5/30/97
6/02/91
6/02/97
8/28/97
1/23/91
6/02/91
6/02/97
6/11/97
3/18/97
6/02/91
HNF-341O, Rev. O
STATUS----------ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVS
ACTIVE
ACTIV2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
36
-.-.-———..=========.========.======__-- —----—- .—-----.-.—.=========================.======s=====~===========,______———___7/27/98 Master Index Of Active and Developing Page 29
Tank Farm cpe~ating and Maintenance Procedures_______________________________________________________________________________ ==______________________________ ___-________=________= .==____________----
PRccEDU8E NLN4BER RF.V REV# PRDCEDU8E TITLE---------------- --- --- ---------------------------------------------------------ARP-T-432-022
ARP-T-432-023
RRP-T-432-024
ARP-T-432-025
ARP-T-432-025
RRP-T-432-026
ARP-T-432-026
RRP-T-432-029
ARP-T-701-0001
RRP-T-701-0001
ARP-T-701-0002
ARP-T-701-0002
RRP-T-701-0003
ARP-T-701-0003
ARP-T-701 -0004
ARP-T-701-0004
RRP-T-701-0005
RRP-T-701-0005
RRP-T-791-0006
RRP-T-101-OOO6
ARP-T-701-0007
RRP-T-101-OOO7
ARP-T-801-001
RRP-T-801-001
B
B
B
A
B
A
B
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
0
0
1
4
0
2
0
0
6
0
0
0
0
0
4
0
1
0
4
0
1
0
3
0
SlNGLE PLC FAILURE
UNINTERRUPTIBLE POWER SYSTEM (UPS) ALAN.!
lNPUT/OUTPUT (1/01 MoDULE FAILuRE
l~sTRMNT FAILum
lNSTR~NT ml Lum
ARSA 8AD1ATION MONITOR
AREA RADIATION MONITOR
AMMONIA ALAAM
RESPOND TO PANEL A ALM.MS AT 242-S EVAPORATOR
RESPOND TO PANEL A ALA8MS AT 242-S EVAPORATOR
R2SPOND TO PANEL B ALM.MS AT 242-S EVAPO~TOR
RESPOND TO PANEL B -S AT 242-S EVAPORATOR
RESPOND TO P?NEL C ALM.MS AT 242-S EVAPOmTOR
RESPOND TO PANEL C -S AT 242-S EVAPORATOR
R3SPOND TO PANEL D ALARMS AT 242-S EVAPOmTOR
RESPOND TO PANEL D ALA8MS AT 242-S EVAPORATOR
8ESPOND TO PANEL E ALASMS AT 242-S EVAPORATOR
RBSPOND TO PANEL E ALARMS AT 242-S EVAPORATOR
R3SPOND TO PRNEL F ALRSMS AT 242-S EVAPORATOR
R3SPOND TO PANEL F ALARMS AT 242-S EVAPORATOR
RESPOND TO PANEL O ALARMS AT 242-S EVAPOILITOR
A3SPOND TO PANEL G ALARMS AT 242-S EVAPOWiTOR
RESPOND TO ALARMS AT 244-TX DCRT AND 242-T EVAPORATOR
RESPONi TO ALARMS AT 244-Tx ERT AND 242-T EvAPOF@,TOR
HNF-341O, Rev.
REL3ASE DATE----------------- _________
9!02/97
5/19/98
2/26/98
2/26/9!3
11/06/96
4/15/98
6/22/98
7/19/95
1/19/95
1/08/98
9/27/97
2/21/98
2/06/90
9/21/97
0
STATUS----------
AcTIVE
ACTIVE
AcTIVE
ACTIV8
REVISING
ACTIVE
REVISING
AcTIVE
A~lVE
R2v1S1NG
ACTIVR
REvISING
ACTIV3
REVISING
AmIVE
F.BVISING
ACTIVE
8EVIS1NG
ACTIVE
REVISING
AcTIVE
R2v1S1NG
ACTIVE
R2VIS1NG
37
-========.==._———— .=========.===.======.==...==-.====.===========-=============================.=7/27/98 Ua.ster Index of Active and Developing
.==========Page 30
Tank Farm Gperating and Maintenance Procedures-============================================ ====.==========.===========----------- ----
PRDCEDW mER________________ATP-040-001
ATP-040-002
CPS-T-14 9-00010
OSD-T-151-00007
OSD-T-151-OOOOS
OSD-T-151-OOO1O
OSD-T-151-00011
OSD-T-151-00012
OSD-T-151-00013
OSD-T-151-00014
OSD-T-151-00015
OSD-T-151-00016
OSD-T-151-00017
OSD-T-151-00018
OSD-T-151-00019
OSD-T-151-00025
OSD-T-151-00026
OSD-T-151-00021
OSD-T-151-00029
OSD-T-151-00030
OSD-T-151-00031
DTP-020-001
OTP-060-001
OTP-060-002
REV RRV# PROCEDURE TITLE RELEASE DATE--- --- -------------------------------------------------------------------------- ---------
STANDARD-E HYDRCGEN MoNITORING SYST2N FIELD ACCEPTANCE TEST PRCXEDURR 8/05/97
A
H
H
E
D
c
D
D
A
B
c
D
F
B
A
A
A
B
B
B
A
A
2
5
0
20
2
6
4
2
15
5
9
2
10
0
1
0
0
0
1
21
4
0
2
3
SALTWELL JET PUNP A2ssMBLY RUN-IN ACCEPTANCE TEST PRCKIEDURE 4/01/98
WRSTE ST0R4GE IN COUSLE-SHELL TANKS AND A3SCC1ATED EQUIFNENT 8/25/97
OPESATING SPEC1F1CATIONS FOR 241-AN,AP,AW,AY,AZ & St TANK FARMS 6/24/90
FOR THE 204-AR WASTE FOR 204-AR wASTE UNLOADING FACILITY 10/20/94
OPERATING sPEC1F1CATIONS FOR PREsSURI.CHECKING OF ALi DIRECT BURIED AND CR 6/23/98
oPERATING SPEC1F1CATION FOR SAL’3TJRLLRECEIVER VESSELS 7/22/96
OPEFTiTING SPEC1F1CATIONS FOR THE 242-A EVAPORATOR
oPERATING SPEC1F1CATION FOR SINGLS-SKSLL WA3TE STORAGE TANKS
oPERATING SPEC1F1CATION FOR THE 244-AR VAULT FACILITY
oPERATING SPEC1F1CATIONS FOR MISCELLANEOUS FACILITIES
oPERATING SPEC1F1CATIONS FOR THE 241-A-702 VESSEL VENT1IATION SYSTEN
oPESATING SPEC1F1CATIONS FOR AGING-W%TE OPERATIONS IN 241-AY AND 241-A2
oPERATING SPECIF1CA1ONS FOR ACTIVS POND PND CRIB DISPOSAL SITE
oPERATING SPEC1F1CA1ONS FOR W-030
OPERATING SPEC1F1CATIONS FOR THE BURIAL GRoUNDS
OPERATING SPEC1F1CATIONS FDR THE TRANSURANIC STORAGE AND ASSAY FACILITIES
OPERATING SPEC1F1CATIONS FOR THE 213-W FAD1oACT1VE SOLID WASTE CCNPACTOR F
OPERATING SPEC1F1CATIONS FOR THE LIQU1D EFFLUENT RETENTION FACILITY
OpER.ATINGSPEclFICATIONs FOR WATCH LIST TANKS
OPERATING SPEF1C1ATIONS FoR TANK FASN LEAK DETECTION
PERFOSM OPERATIONAL TESTING FOR THE LR-56 cASK TRAILER
OFEBATION TEST PRCCEDURE FOR THE 241-A-101 500 C5W EKHAUSTER
PROCESS TEST TANK 241-c-106 296-P16 EKKAUSTER OUTAGE
HNF-341O, Rev. O
1/22/96
10/01/97
12/21/94
1/11/96
10/20/94
10/01/97
7/05/95
1/06/98
5/02/91
6/01/98
12/04/96
10/lB/96
6/06/97
STATUS----------ACT1V2
AcT1V2
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIVE
ACTIUE
DEVELOPING
DEVELOPING
DEVELOPING
ACTIVE
ACT1V2
?.CTIVE
DEVELOPING
ACTIVE
ACTIVE
32
-=====.=====...... .... ... .. ...=.=.=7... ====. . . ...= .== .=.. .====. .===. ==== .== .==== ——— —====.. __
7/27/90
-—-
Master Index of Active and DevelopingTank Farm operating and Maintenance Procedures
---_-_———— -—____
Page 31
pRCCEDUM mER REV Fw,v#PRccEDum TITLE RELEAsE DATE.--------------- ---OTP-200-001
OTP-200-002
CTP-200-003
C’TP-200-004
DTP-21O-OO1
OTP-220-001
OTP-320-001
oTP-320-002
OTP-320-003
OTP-320-004
DTP-320-005
OTP-320-006
OTP-320-007
OTP-320-008
OTP-320-009
OTP-32O-O1O
DTP-320-011
OTP-W030-001
0TP+030-003
POTP-T-W030-008
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
A
--- -------------------------------------------------------------------------- _________14
1
1
6
2
0
4
2
3
4
0
0
0
0
0
2
0
3
0
1
0pE8AT10N TEST PRDCEDURXS FOR THE A-1OI PUMPING AND 1N6TRmNTAT10N CONTRO
OPESATIONAL TEST PRCCEDURE FOR THE BELHAvEN FLPJWABLE GRS MONITOR MODEL FG
OPERATIONAL TEST PRCCEDU~ FLNC.IAGLEsA3 MONITOR MODEL
OPERATION TEST PRWEDURE FOR 600 SERIES PUNPING AND INSTRWNTATION CONTRO
R7,-101MIXER PUNP OPERRTIONAL TEST PRCCEDUR3
W-A-002, BACRUP DIESEL GENEmTOR SET
W-320 ANNULUS VENT1LATION SYSTEM OPERATIONAL TEST
w-320 SLURRY TRANSFER SYSTEM p8E0PEItRT10NALTEST
W-320 SUPERNATE TRANSFER SYSTEM PREOPERATIONAL TEST
W-320, TANK 241-C-106 V2NT1LRTION EXHAUST SYST2N PREoPERATIoNAL TEST
TMK 241-c-106 IN-TANK INAGING SYSTm OPEEAT1ONAL TEST pRCCEDURE
PROJECT W-320 CATHODIC PRoTECTION SYSTEM OPEAATIONAL TEST PROCEDURE
OPERATIONAL TEST F.MZRGENCTBACKUP 241-c-106 1000 CEN EXJIRUSTER
OPERATIONRL TEST EMERGENcT BACKUP 241-AY-102 1000 CFM EXHAUSTER
OPERATIONAL TEST E!.5RGENcTBACKUP 241-AY-102 ANNULUS 1000 CFM E~USTER
P+320 ENRAF SERIES 054 DENSITCMETER OPEPATIONAL TEST
W-320 wRSS 296-c-106 HVAC SYSTEM (TIE-IN) OPERATIONRL TEST
W-030 oPEEATIoNAL TEST PRcCEDURE INTEGRATED SYST2N TEST
CRTHODIC PROTECTION STSTENS OPERATIONAL TEST pRCCEDURE
w-030 PP.E-OPERATIONAL TEST pRCCEDUSX INTEGRATED SYSTEM TEST
12/23/97
11/22/96
2/28/91
4/21/90
1/21/98
5/27/97
2/12/90
7/18/90
6/17/90
7/15[96
5/11/98
5/19/98
7j02J98
7/02/98
1/02/98
6/24/98
7/22/98
7/29/97
FAIRCHILD MODELS T-5100B-1, T-5100B-4 , 5200, fl? T-5600 1/P TRANSDUCERS 2/19/98w~k?s?m:s~:~~x?=~~WFORD-BUILT SURVEILLANCE puLsE AMPLIFIER DIs<iINAlOi (pm) USED IN LEA 3/06/95
SA1c/EADEco MODEL H-809B, H809c, H81O, 787, H-S09V, HD-29, HD-29A, HD-66A
%%$~ +-=k at10/20/95
PM LEEDS AND NORTHRUP SPEEECWAX M NARX 111 RECORDER=dl~~t ~k ae
5/27/91
sTATUS
ACTIVE
ACTIVE
ACT1V2
ACTIVF.
ACTIVE
ACTIVR
ACTIVE
ACTIVE
ACTIVE
ACT1~
ACT1V2
ACTIVE
ACTIVE
ACTIVE
ACTIVP
ACTIVE
DEVELOPING
ACTIVE
DEmLOPING
ACTIVE
ACTIVE
ACT1V3
ACTIVS
ACTIVE
HNF-341O, Rev. O
39
-===..===-.=. .—.——-=.—.—=======.=========================.======---- ---- .=========.============================m... -- --- .---— ———. -. ________ —————
7/27/98
-------
Master Index of Active and Developing Page 32Tank Farm Cperating and Maintenance Procedures
-=====.=====.===========------ ====================================_________==================== .=====___.______==._T------------------------- _____________------ ---------
PROCEDURE NUNBER REV AEV# PRCCEDURS TITLE RELEASE DATE STATUS---------------- --- --- -------------------------------------------------------------------------- _________ _._-------
w-mm~ F1!H~R cONTRO:s V~fJRD~R, TypE RD221, TypE RD222 2/24/98
WaE@p@BwY&~
ACTIVE
::>. m~--~-=fl~~...........m. .....-’“A.-w.. ..:.
i$OtiORO‘7:01~6i SINGLE STATION MICRO CONTROLLERS “’ “,A .— ...
2/25/98~ -Asmzw ‘ “
ACTIVE
PSCP-4-265 0 A34ETEKMODEL 57Z “tiTERicONTROLLiR~~#@~@
-Bm@%.m+~m
2/25/98 ACTIV2
w.wmF&Fm@m% LEEDS AND NORTHRUP SPEEWWAX 1650 AND 2500 MULTIPOINT RECOF.DERS 2/25/98 ACT1V2chart nrims - Prcgr-le: Limit. ..1* - tis net appear to have e*/*t9 ~$g Lmt verify
PscP-4-311 0 FOXEORO E27R SERIES S1NGLE-STATION ELECTRONIC INDICATING RECORDERS; --m
AcT1v2
PscP-6-036 1 REPUBLIC P0300ccE sERIES PNEUNATIC PRESSURE TRAN2N1TTER 2/25/98 ACT1V2
PscP-6-040 1 HONEYWELL SLECTRONIK NUN-INDICATING PNS*TIC T9.AN2NITTERrMODEL Y158N31B @B~~m~
2/25/98 ACTIVS‘mmw.~
PSCP-6-041 1 c TAYLoR 300 SERIES ~IFFERENTIAL p~sku~ TRAN2t41TTER
~-w
2/25/98
~=’=”-”
ACTIVE
PSCP-6-092. .
1 B AcTIoN )Ak liSiRUNXNTS WITH RTD AN~~R1kE INPUT AND VOLTAGE CURRENT OUTPU 2/25/90 ACTIVE
PscP-6-099 2 A CAL1BAATION PRCCEDUR2 FOR TEMPERATURE .3WITCH 2/25/90 ACTIVE
PscP-6-141 2 A rhwER lNSTRUNENTS 600 SERIES DIFPBRENTIAJ psmsum TEAN3NITTER 2/25/90 AcTIVE
PscP-6-275 o D FOxsORO MODEL E83 VORTEX FLONMBTERS 10/26/94 AcTIvE
s-cc-0044 A2DucED PRESSURE BACKFLOW A5SSMSLY TEST USING A DIFFERENTIAL PRXSSUEE GRUG
~@w=&%@&:@~?*”*~~
6/06/96 ACTIVE.,,.M*w=-~mww*~ w~mw?w-=w~r%3
.,,.--.”
HNF-341O, Rev. O
40
DISTRIBUTION SHEETTo From Page 1 of 1
Distribution Data Management/Technical Date 09/21/98Basis and Planning
Project Title/Work Order EDT No. EDT-622476
HNF-341O, Rev. 0, “Year 2000 TWRS Maintenance Procedure ReviewReport”