PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: [email protected] Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000 Sprachen: En Edition Dezember 2004

Transcript of PRIMERGY RX300 S2 Server System -...

Page 1: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

PRIMERGY

PRIMERGY RX300 S2Server System Monika SpanjaartFujitsu Siemens Computers GmbH München81730 Muniche-mail: email: [email protected].: (089) 61001160Fax: (++49) 700 / 372 00000 Sprachen: En

Edition Dezember 2004

Page 2: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Fax forms for sending us your comments are included inthe back of the manual.

There you will also find the addresses of the relevantUser Documentation Department.

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and Trademarks

Copyright © 2004 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

This manual is printed on paper treated with chlorine-free bleach.

Page 3: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Introduction

Procedure

Safety notes

Replacement routines

Appendix

Index

Page 4: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 5: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Overview of the documentation . . . . . . . . . . . . . . . . . . 11.2 Notational conventions . . . . . . . . . . . . . . . . . . . . . . . 4

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4 Replacement routines . . . . . . . . . . . . . . . . . . . . . 134.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 134.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 134.2 Replacing the operating panel . . . . . . . . . . . . . . . . . . 134.3 Replacing USB module . . . . . . . . . . . . . . . . . . . . . 154.4 Replacing the floppy disk drive . . . . . . . . . . . . . . . . . 174.5 Replacing the LocalView module . . . . . . . . . . . . . . . . 174.6 Replacing CD/DVD drive . . . . . . . . . . . . . . . . . . . . . 174.7 Replacing the Power backplane . . . . . . . . . . . . . . . . . 174.8 Replacing the SCSI backplane . . . . . . . . . . . . . . . . . 184.8.1 Replacing the 1st SCSI-Backplane . . . . . . . . . . . . . . . 184.8.2 Replacing the 2nd SCSI backplane . . . . . . . . . . . . . . . 204.9 Replacing the hot-plug PCI board . . . . . . . . . . . . . . . . 204.10 Replacing the IDTemp Combo . . . . . . . . . . . . . . . . . . 224.11 Replacing the processor heat sink . . . . . . . . . . . . . . . . 234.12 Replacing the system board . . . . . . . . . . . . . . . . . . . 24

5 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275.1 Board layouts . . . . . . . . . . . . . . . . . . . . . . . . . . 275.1.1 Operating panel . . . . . . . . . . . . . . . . . . . . . . . . . 275.1.2 USB panel board . . . . . . . . . . . . . . . . . . . . . . . . 275.1.3 Power Backplane . . . . . . . . . . . . . . . . . . . . . . . . 285.1.4 SCSI Backplane . . . . . . . . . . . . . . . . . . . . . . . . . 305.1.4.1 1st SCSI backplane and 2nd 2-channel SCSI backplane . . . . 305.1.4.2 2nd 1-channel SCSI backplane . . . . . . . . . . . . . . . . . 325.1.5 IDTemp Combo . . . . . . . . . . . . . . . . . . . . . . . . . 335.1.6 System Board . . . . . . . . . . . . . . . . . . . . . . . . . . 345.2 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Service Supplement

Page 6: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 7: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

1 IntroductionThe PRIMERGY RX300 S2 Server is an Intel-based server for medium-sized networks and large companies. The server is suitable for use as a file server as well as an application, information, or Internet server.

1.1 Overview of the documentation

Concept and target groups

This Service Supplement completes the information given in the Operating Manual, the Options Guide and the Technical Manual of the system board.

The activities described in this manual may only be performed by service personnel.

Service CD

Service partners of Fujitsu Siemens can order a Service CD. On the CD the following manuals are available in pdf format:

– The “Security” manual– The Operating Manual for PRIMERGY RX300 S2– The Technical Manual for the system board D1889– The Options Guide for PRIMERGY RX300 S2– The Service Supplement PRIMERGY RX300 S2– The “BIOS Setup” manual

Service Supplement 1

Page 8: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

2

Overview of the documentation Introduction

Info

Deta

Feat

Insta– E– O– C– I

Trou

Insta– h– h– h– h

Infor– F– B– J– L– R

Exte

– E– I

p– I– I– I– I– I– I– I– C

S– C

P

Cab

Table

rmation/procedure Manual

iled safety notes Safety

ures and technical data of the server Operating Manual

llation and operation, among other things:xternal portsperationonfiguration of the server

nstallation of the rack mounting kit

bleshooting

llation/removal of all hot-plug components:ot-plug power supply unitsot-plug hard disk drivesot-plug magnetic tape driveot-plug PCI boards

mation about the system board:eatures of the system boardoard layoutumper settingsED displayseplacing the battery

Technical Manual

nsions and upgrades

xtending/replacing the main memorynstalling a second processor / replacing the rocessor / replacing the heat sink

nstalling the ROMB upgrade kitnstalling accessible drivesnstalling a Local View modulenstalling controller in the non-hot-plug PCI slotsnstalling RemoteView componentsnstalling the external SCSI interfacenstalling a parallel interfaceonverting from the SCSI 1-channel to the CSI 2-channel versiononverting from low-profile slots to standard CI slots

Options Guide

ling

1: Overview of the documentation PRIMERGY RX300 S2

Service Supplement

Page 9: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Service Supplement 3

Introduction Overview of the documentation

I For some components only the installation routine is described in the Options Guide. Removing this components proceed in reverse order.

Replacement routines:– Replacing the operating panel– Replacing the USB connector panel– Replacing the floppy disk drive– Replacing the DVD-ROM drive– Replacing the processor fan holder– Replacing the Power backplane– Replacing the SCSI backplane– Replacing the hot-plug PCI print– Replacing the IDTEMP Combo– Reinstalling the processor heat sink– Replacing the system board

Service Supplement

Settings and Board layouts

BIOS setup BIOS Setup

Information/procedure Manual

Table 1: Overview of the documentation PRIMERGY RX300 S2

Page 10: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Notational conventions Introduction

1.2 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands, menu items or software programs.

„Quotation marks“ indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Table 2: Notational conventions

4 Service Supplement

Page 11: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

2 ProcedureV CAUTION!

The actions described in these instructions should only be performed by service personnel.

Ê First of all please familiarize yourself with the safety instructions in the chapter “Safety notes” on page 7.

Ê Ensure that all required manuals (see Service CD) are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server, the Options Guide for the server and the Technical Manual for the system board.

Ê Shut down the server correctly, switch it off, pull out the power plug, and open the server as described in the section “Opening the server” on page 13.

Ê Replace the faulty component as described in the relevant chapter.

Ê Close the server.1

Ê Connect the cables. 1

Ê Connect the server to the power outlet.1

Ê Start the operating system.1

Ê If necessary, configure the server as required.1

1 This procedures are described in the Operating Manual.

Service Supplement 5

Page 12: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 13: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

3 Safety notesI The following safety notes are also provided in the “Safety” manual.

This device complies with the relevant safety regulations for data processing equipment.

V CAUTION!

The actions described in these instructions should only be performed by service personnel.

Before operating the device

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

● The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

Service Supplement 7

Page 14: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove all power plugs from the grounded insulated sockets.

V CAUTION!

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.

● Data cables to peripheral devices must be adequately shielded.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug and contact your sales outlet or customer service team.

● Proper operation of the device (in accordance with IEC 60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations

8 Service Supplement

Page 15: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

V CAUTION!

● The components or parts marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

● You may only set those resolutions and refresh rates specified in the „Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board).

● Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste.

● The battery must be disposed of in accordance with local regulations concerning special waste.

● Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board.

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Service Supplement 9

Page 16: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

Notes on handling CDs and CD-/DVD-ROM drives

V CAUTION!

● Use only CDs in proper condition in the CD-/DVD-ROM drive of your server to prevent data loss, damage to the device and injuries.

● Therefore, check each CD for damage, cracks, breakage etc. before inserting it in the drive.

Please note that any additional labels applied may change the mechanical properties of a CD and cause imbalance.

Damaged and imbalanced CDs can break at high drive speeds (data loss).

Under certain conditions sharp-edged pieces of broken CDs can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).

I You protect the CD-/DVD-ROM drive and prevent mechanical damage, as well as premature wearing of the CDs, by observing the following suggestions:

– Only insert the CDs in the drive when needed and remove them after use.

– Store the CDs in suitable sleeves.– Protect the CDs from exposure to heat and direct sunlight.

10 Service Supplement

Page 17: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

Note about the laser

The CD-/DVD-ROM drive is classified for laser class 1 according to IEC 60825-1.

V CAUTION!

The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.

Never remove parts of the CD-/DVD-ROM drive assembly!

Modules with electrostatic-sensitive components:

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug from the power socket before inserting or removing components containing ESDs.

● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Only touch the components at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

Service Supplement 11

Page 18: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).

12 Service Supplement

Page 19: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

4 Replacement routinesV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 7.

4.1 Preparation

I You will find a detailed description of ’Opening the server’ and ’Removing the front cover’ in the Options Guide PRIMERGY RX300 S2.

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the on/off switch.

Ê Pull all power connectors out of the power outlets.

4.1.1 Opening the server

Ê Loosen the two knurled screws and pull the server as far as possible out of the rack.

Depending on how accessible the server is in the rack cabinet, it can make sense to remove it from the cabinet. You will find a detailed description in the Options Guide or the Operating Manual.

Ê Push the two locking buttons and remove the cover.

Ê Slide the cover to the rear side and remove it.

4.2 Replacing the operating panel

Ê Open the server as described in the section “Opening the server” on page 13.

Service Supplement 13

Page 20: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the operating panel Replacement routines

Figure 2: Unlocking the operating panel module

Ê Press the locking handle downward.

Ê Push the frame to the front side.

Figure 3: Removing the connector from the operating panel

Ê Remove the cable from the operating panel and pull it out of the cable clamp.

Ê Pull the frame outward to the front side.

14 Service Supplement

Page 21: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacement routines Replacing USB module

Figure 4: Removing the operating panel out of the frame

Ê Remove the operating panel out of the frame.

The installation takes place in reverse order.

Information about the cabling you will find the „appendix“ of the Options Guide.

4.3 Replacing USB module

Ê Open the server as described in the section “Opening the server” on page 13.

Ê Remove the USB connector from the system board.

Service Supplement 15

Page 22: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing USB module Replacement routines

Figure 5: Unlocking the USB module frame

Ê Unlock the USB module fame.

Ê Push USB module frame to the front side.

Figure 6: Removing the USB module frame

Ê Pull the USB module frame out.

Ê Remove the cable from the connector of the USB panel and out of the clamp.

Ê Remove the backplane.

16 Service Supplement

Page 23: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacement routines Replacing the floppy disk drive

The installation takes place in reverse order

I Do not forget to replace the insulation foil and be sure that the lower border of the black cover is inside of the metal holder.

Information about the cabling you will find in the „appendix“ of the Options Guide.

4.4 Replacing the floppy disk drive

You will find a detailed description of ’Replacing the floppy disk drive’ in the Options Guide PRIMERGY RX300 S2.

4.5 Replacing the LocalView module

You will find a detailed description of ’Replacing the LocalView module’ in the Options Guide PRIMERGY RX300 S2.

4.6 Replacing CD/DVD drive

You will find a detailed description of ’Replacing the CD/DVD drive’ in the Options Guide PRIMERGY RX300 S2.

4.7 Replacing the Power backplane

Ê Open the server as described in the section “Opening the server” on page 13.

Service Supplement 17

Page 24: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the SCSI backplane Replacement routines

Figure 7: Removing power backplane

Ê Remove all cables.

Ê Remove the screw.

Ê Push the backplane to the right side out of the stamping in the plate.

Ê Take the backplane out.

The Installation takes place in reverse order.

Information about the cabling you will find the „appendix“ of the Options Guide.

4.8 Replacing the SCSI backplane

Ê Open the server as described in the section “Opening the server” on page 13.

4.8.1 Replacing the 1st SCSI-Backplane

Ê Remove the fan box.

I You will find a detailed description of ’Removing the fan box’ in the Options Guide PRIMERGY RX300 S2.

18 Service Supplement

Page 25: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacement routines Replacing the SCSI backplane

Figure 8: Removing the 1st SCSI backplane

Ê Remove all cables from SCSI Backplane.

Ê Open the knurled screw (1).

Ê Twist the SCSI backplane holder t slightly (2).

V CAUTION

Do not damage the hooks which form a hinge for the SCSI backplane.

Ê Pull the SCSI backplane holder out (3).

2 3

1

Service Supplement 19

Page 26: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the hot-plug PCI board Replacement routines

Figure 9: Removing the backplane from the holder

Ê Unlock the backplane from the snap-fits.

Ê Remove the SCSI backplane from the holder.

The Installation takes place in reverse order.

4.8.2 Replacing the 2nd SCSI backplane

I You will find a detailed description of ’Replacing 2nd SCSI backplane’ in the Options Guide PRIMERGY RX300 S2.

4.9 Replacing the hot-plug PCI board

Ê Open the server as described in the section “Preparation” on page 13.

Ê e controllers from both hot-plug PCI slots.

Ê Remove the cable from the connector on hot-plug Board.

20 Service Supplement

Page 27: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacement routines Replacing the hot-plug PCI board

Figure 10: Removing the hot-plug board

Ê Unlock the snap-fits.

V CAUTION

Be very careful, the PCI holders are delicate and easily damaged.

Ê Remove the board.

Ê Insert the new board and press it down.

V CAUTION

Be careful, the PCI holders are delicate and easily damaged. They must lock correctly.

The Installation takes place in reverse order.

Information about the cabling you will find in the „appendix“ of the Options Guide.

Service Supplement 21

Page 28: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the IDTemp Combo Replacement routines

4.10 Replacing the IDTemp Combo

This board includes two important system components:– EEPROM for the chassis ID and Ident number of the server– temperature sensor for monitoring the environment temperature

The data for the EEPROM, and the current temperature values as well, are transmitted to the system board via the connected I2C bus. The IDTEMP combo must be correctly installed in order:– to monitor the temperature correctly,– to enable the server management to display the correct system picture,– to install the server using ServerStart.

V CAUTION!

The IDTEMP combo may not be changed because of the information which is in the EEPROM to identify the system.If the combo is defective, a spare part must be ordered specially by specifying the ident number (see the type label).

Ê Open the server as described in the section “Preparation” on page 13.

Ê Remove the fan box.

I Information to this item you will find in the ’PRIMERGY RX300 S2 Options Guide’.

Figure 11: Removing the IDTemp Combo with its holder

Ê Push the holder with the IDTemp Combo outward.

22 Service Supplement

Page 29: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacement routines Replacing the processor heat sink

Figure 12: Removing the IDTemp Combo from its holder

Ê Remove the connector clamp.

Ê Insert the IDTemp Combo into the holder.

The Installation takes place in reverse order.

Information about the cabling you will find in the „appendix“ of the Options Guide PRIMERGY RX300 S2.

4.11 Replacing the processor heat sink

Ê Open the server as described in the Options Guide PRIMERGY RX300 S2.

Ê Remove the air duct over the main memory and the processors (see Options Guide PRIMERGY RX300 S2).

Ê Loosen the four screws on the heat sink socket in a crossover pattern (Options Guide PRIMERGY RX300 S2).

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Clean the upper side of the processor using a lint-free cloth.

Ê Remove the protective cover from the new heat sink.

Ê Place the heat sink on the processor socket (see Options Guide PRIMERGY RX300 S2).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Service Supplement 23

Page 30: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the system board Replacement routines

Ê Reinstall the air duct over the main memory and the processors (see Options Guide)

The installation takes place in reverse order.

4.12 Replacing the system board

Ê Open the server as described in the section “Preparation” on page 13.

Ê Remove the fan box, processor heat sinks, processors, and PCI controllers. If a riser card is installed, it has to be removed too.

I Information to this item you will find in the ’PRIMERGY RX300 S2 Options Guide’.

Figure 13: Removing the cables from the system board

24 Service Supplement

Page 31: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacement routines Replacing the system board

Ê Remove the cables from the system board.

Ê Remove the part of the cable duct cover, that is marked.See Options Guide PRIMERGY RX300 S2 in chaper „external SCSI interface“.

Ê Remove all screws. See also board layout in section “System Board” on page 34.

Figure 14: Removing system board

V CAUTION

Hold the board at its memory slots of the RAID cache and the main memory, but not at the remaining heat sinks.

Ê Pull the system board somewhat to the front side (1).

Ê Pull the system board out. You will need to tilt it at an angle to do this (2).

Ê Insert the new system board. You will need to angle this in order to fit it, as you did when removing the old one.

1

2

Service Supplement 25

Page 32: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the system board Replacement routines

V CAUTION

Be careful with the I/O field insulation. When you insert the system bord, the I/O field insulation can be removed from the I/O field and can be pressed down.

Ê Position the system board carefully, ensuring the exact alignment of the holes with the corresponding supports.

Figure 15: Springs for the heat sink

V CAUTION

Springs under the system board must be aligned properly under the screw holes.

Ê Press the board down at both the fixing points (the two back marked holes on the layout drawing “System Board” on page 34).

Ê Fix the board with all screws.

I The 6 screws under the fan cage must fix also the black plastic holders for the fan cage.

The Installation takes place in reverse order.

Information about the cabling you will find in the „appendix“ of the Options Guide.

26 Service Supplement

Page 33: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

5 Appendix

5.1 Board layouts

5.1.1 Operating panel

Part number: A3C40052694

Figure 16: Operating panel

5.1.2 USB panel board

Part number: A3C40052698

Figure 17: USB panel board

Connector Description

X1 Connector operating panel to system board

X1

X1 X2

Service Supplement 27

Page 34: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Board layouts Appendix

5.1.3 Power Backplane

Part number: A3C40051768

Figure 18: Power Backplane

Connector Description

X1 Connector USB cable to system board

X2 External USB connectors

Connector Cable number Description

X1 - SV 1

X2 - SV 2

X3

X4

X5

X6

X7

X1

X2

28 Service Supplement

Page 35: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Appendix Board layouts

X3 A3C40057188 Power 24 polig to system board

X4 A3C40057447 12 V to system board

X5 A3C40057191 Power to 1st SCSI backplane

X6 A3C400058003 power to 2nd SCSI backplane and CD-ROM drive

X7 A3C40057192 PC 98 connector to system board

Connector Cable number Description

Service Supplement 29

Page 36: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Board layouts Appendix

5.1.4 SCSI Backplane

5.1.4.1 1st SCSI backplane and 2nd 2-channel SCSI backplane

Part number: A3C40052609

Figure 19: 1st SCSI backplane side facing the system board

Connector Description

X1 SCSI cable

X5 Power

X7 SCSI control cable

X8 I2C connector

X1

X7

X8

X5

30 Service Supplement

Page 37: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Appendix Board layouts

Figure 20: 1st SCSI backplane side facing hard disks

X2

X3

X4

Service Supplement 31

Page 38: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Board layouts Appendix

5.1.4.2 2nd 1-channel SCSI backplane

Part number: A3C40053292

Figure 21: 2nd SCSI Backplane facing to the system board

Connector Description

X1 SCSI cable to the system board

X5 Power

X6 I2C connector

X7 SCSI control cable

X8 SCSI cable to the 1st SCSI backplane

X1

X7

X6

X5

X8

32 Service Supplement

Page 39: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Appendix Board layouts

Figure 22: 2nd SCSI backplane side facing the hard disks

5.1.5 IDTemp Combo

Figure 23: IDTemp Combo

Connector Description

X1 I2C connector

X2

X3

X4

X1

Service Supplement 33

Page 40: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Board layouts Appendix

5.1.6 System Board

Figure 24: System board

34 Service Supplement

Page 41: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Appendix Cabling

I You will find the connector description and the extension in the „technical manual of system board D1889“.

5.2 Cabling

I You will find the drawings of the cabling and the list of cabling in the „Options Guide PRIMERGY RX300 S2“

Service Supplement 35

Page 42: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Cabling Appendix

36 Service Supplement

Page 43: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Index

EESD (devices sensitive to electrostatic

discharge) 11ESD-sensitive devices 11

Hheat sink 23holder of the 1st SCSI backplane 19hot-plug PCI board 20Hot-plug Print 20

II/O field insulation 26IDTemp Combo 22

Llight-emitting diode (LED) 11lithium battery 9locking handle operating panel

module 14locking handle USB module 16

Mmeaning of the symbols 4

Nnotational conventions 4note about the laser 11

Ooperating panel 13Overview documentation 1

Pprocessor heat sink 23

Ttarget group 1touche points 11

Service Supplement 37

Page 44: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Index

38 Service Supplement

Page 45: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Comments on PRIMERGY RX300 S2 Service Supplement

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MunichGermany

Fax: (++49) 700 / 372 00000

email: [email protected]://manuals.fujitsu-siemens.com

Page 46: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 47: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Comments on PRIMERGY RX300 S2 Service Supplement

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MunichGermany

Fax: (++49) 700 / 372 00000

email: [email protected]://manuals.fujitsu-siemens.com

Page 48: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 49: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

PRIMERGY

PRIMERGY RX300 S2Server System Options GuideMonika SpanjaartFujitsu Siemens Computers GmbH München81730 Muniche-mail: email: [email protected].: (089) 61001-160Fax: (++49) 700 / 372 00000U41601-J-Z156-1-76Sprachen: En

Edition December 2004

Page 50: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Fax forms for sending us your comments are included inthe back of the manual.

There you will also find the addresses of the relevantUser Documentation Department.

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and Trademarks

Copyright © 2004 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

This manual is printed on paper treated with chlorine-free bleach.

Page 51: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Introduction

Procedure

Safety notes

Preparation

Main memory

Processors

ROMB (RAID on Motherboard)

Accessible drives

PCI slots

RemoteView components

Continued

Page 52: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 53: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

External SCSI interface

Parallel interface

Converting from 1- to 2-channel version

Converting from low-profile to standard PCI Slots

Completion

Appendix

Related publications

Index

Page 54: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 55: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Overview of the documentation . . . . . . . . . . . . . . . . . . 11.2 Options and upgrade . . . . . . . . . . . . . . . . . . . . . . . 31.3 Notational conventions . . . . . . . . . . . . . . . . . . . . . . . 6

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 154.1 Removing the server form the rack . . . . . . . . . . . . . . . 154.2 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 17

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 195.1 Memory module population . . . . . . . . . . . . . . . . . . . 195.2 Upgrading/replacing the main memory . . . . . . . . . . . . . 22

6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . 276.1 Installing a second processor . . . . . . . . . . . . . . . . . . 276.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . . 32

7 ROMB (RAID on Motherboard) . . . . . . . . . . . . . . . . 357.1 Installing the ROMB upgrade kit . . . . . . . . . . . . . . . . . 35

8 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . 378.1 Installing a FD drive . . . . . . . . . . . . . . . . . . . . . . . 388.2 Installing a LocalView module . . . . . . . . . . . . . . . . . . 438.3 Installing the CD/ DVD-ROM drive . . . . . . . . . . . . . . . . 50

9 PCI slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559.1 Installing a PCI controller in a low-profile slot . . . . . . . . . . 569.2 Installing the PCI controller in the riser card . . . . . . . . . . . 589.3 Population of the PCI slots . . . . . . . . . . . . . . . . . . . . 61

10 RemoteView components . . . . . . . . . . . . . . . . . . . 6310.1 Installing the chipDISK . . . . . . . . . . . . . . . . . . . . . . 6310.2 RemoteView Service Board S2 LP . . . . . . . . . . . . . . . 64

U41601-J-Z156-1-76 Options Guide

Page 56: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Contents

11 External SCSI interface . . . . . . . . . . . . . . . . . . . . . 6711.1 Installing the external SCSI interface . . . . . . . . . . . . . . . 67

12 Parallel interface . . . . . . . . . . . . . . . . . . . . . . . . . 7912.1 Installing a parallel interface . . . . . . . . . . . . . . . . . . . 79

13 Converting from 1- to 2-channel version . . . . . . . . . . . . 8513.1 Removing 2nd SCSI backplane . . . . . . . . . . . . . . . . . . 8713.2 Installing 2nd SCSI backplane . . . . . . . . . . . . . . . . . . 90

14 Converting from low-profile to standard PCI Slots . . . . . . 9314.1 Removing lp slot cage . . . . . . . . . . . . . . . . . . . . . . 9314.2 Installing Riser card . . . . . . . . . . . . . . . . . . . . . . . . 96

15 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9915.1 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . . 99

16 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10316.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10316.2 Configuration diagram . . . . . . . . . . . . . . . . . . . . . 10616.3 Hard disk mirroring . . . . . . . . . . . . . . . . . . . . . . . 107

Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

Options Guide U41601-J-Z156-1-76

Page 57: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

1 IntroductionThe PRIMERGY RX300 S2 has been designed for multi-server configurations (clusters), front-end solutions, e-commerce applications and ERP solutions. The PRIMERGY RX300 S2 is outstanding for applications and fields of use that demand maximum scalability, performance and availability in a space-saving rack cabinet.

The PRIMERGY RX300 S2 offers very great expandability with up to 6 hard disks for a rack server and takes up just 2 height units (U) in a 19-inch rack.

1.1 Overview of the documentation

I PRIMERGY manuals are available in PDF format on the ServerBooks CD which is supplied in the ServerView Suite package for every server system.

These PDF files can also be downloaded free of charge from the Internet: at http://manuals.fujitsu-siemens.com you will find an overview page with the online documentation available on the Internet. You can go to the PRIMERGY Server documentation by clicking on “intel based Servers”.

Concept and target groups

This Options Guide shows you how you can expand and upgrade the server.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

The activities described in this manual may only be performed by specialist personnel with technical training.

Additional documentation about the server

The PRIMERGY TX300 S2 documentation comprises the following additional manuals:

– The “Security” manual (printed copy always supplied with the server, and available as a PDF file on the ServerBooks CD supplied)

– The “Guarantee” manual (printed copy always supplied with the server, and available as a PDF file on the ServerBooks CD supplied)

U41601-J-Z156-1-76 Options Guide 1

Page 58: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Overview of the documentation Introduction

– The Operating Manual for PRIMERGY RX300 S2 S2 (PDF available on the ServerBooks CD supplied)

– The Technical Manual for the system board D1889 (PDF available on the ServerBooks CD supplied)

– The “BIOS Setup” manual (PDF available on the ServerBooks CD supplied)– The “PRIMERGY ServerView Suite - ServerStart” manual (printed copy

always supplied with the server, and available as PDF file on the ServerBooks CD supplied)

I You can order a supplementary ServerBooks CD by sending an e-mail to the following address, quoting your server data: [email protected]

Further sources of information:

– Technical Manual on the relevant rack– Manual on the monitor– Manual on ServerView Server Management– Manual on the RemoteView Remote Test and Diagnostics System – Manual on LocalView– Documentation on boards and drives– Documentation on your operating system– Information files on your operating system

(see also chapter „Related publications“ on page 109)

2 Options Guide U41601-J-Z156-1-76

Page 59: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Introduction Options and upgrade

1.2 Options and upgrade

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor.

Upgrading of the main memory

The eight slots for the main memory are suitable for PC2-3200 DDR DIMM memory modules. The organization in four memory banks, 0 to 3, permits rapid memory access with two-way interleaving.

Memory modules must always be incorporated in pairs. A memory bank must always be equipped fully with the same type of memory modules.

ROMB (RAID on motherboard)

The System is extended with an on board Intel I/O processor. If the controller is activated, the on-board 2 channel U320 SCSI-Controller supports RAID Level 0, 1, 10, 5 and 50 on both SCSI channels

"MegaRaid PCI Express™ ROMB" can be activated with two different upgrading kits.

Additional accessible drives

One 3.25-inch bay and one 3,5-inch bay are available for accessible drives.

One 5.25-inch bay can be installed with a 3.5 inch x 0.5 inch floppy disk drive or a LocalView module and the other bay can be installed with a 5.25-inch x 0,5 inch DVD-ROM drive.

LocalView module (alphanumeric system display)

The LocalView module provides you with the option of displaying system infor-mation and hardware system faults alphanumerically. This is an intelligent module with a micro-controller and its own memory, which functions indepen-dently of the server system.

U41601-J-Z156-1-76 Options Guide 3

Page 60: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

4

Options and upgrade Introduction

The Lboth allowmatiothe L

Hard

the inaccoAttacSCSsimpand trepla

Addi

The sa PCwork

PCI sthat hOper

Optio

Optiocontrshortheigh

Rem

RemThe tmemdiagn

ocalView module consists of an LCD display panel and a toggle switch, accommodated in a suitable mount. The mechanical mechanism used s the LCD display panel to be pulled out and flapped out. Further infor-n on operating the display modes are provided in the documentation on ocalView module.

disk drives

stallation up to six HDD modules is possible. Each HDD module can mmodate a SCSI hard disk drive with an SCA (Single Connector hment) interface and a height of at most 1 inch. The connection to the I backplane is made without cables via the SCA interface. This makes it le to plug in or pull out the HDD modules. If the server has a RAID controller he corresponding RAID configuration, faulty HDD modules can also be ced while the system is operating.

tional controllers in non-hot-plug PCI slots

ystem board offers five PCI slots. Slots 1-3 are non-hot-plug PCI slots with I bus speed of 100 MHz. If slot 1 and slot 2 are not occupied, slot 3 can with the PCI bus speed of 133 MHz (IDoubleOP™).

lots 4 and 5 are hot-plug PCI slots which can be equipped with controllers ave hot-plug capability (the hot-plug PCI slots are described in the ating Manual).

nal riser card

nally you can install a Riser card into slot 5, which can be equipped with 3 ollers. The bus speed is 100 MHz. Two slots (6 and 7) can be equipped with standard PCI controllers and slot 8 can be equipped with a full length full t PCI controller.

oteView

oteView provides you with a comprehensive test and diagnostics package. est and diagnostics software is stored on a chipDISK. The chipDISK is a ory component with an IDE interface. In the event of a fault the test and ostics software is automatically loaded from the chipDISK and executed.

Options Guide U41601-J-Z156-1-76

Page 61: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

U41601-J-Z156-1-76 Options Guide 5

Introduction Options and upgrade

RemoteView Service Board S2 LP (2U/3U)

The RemoteView Service Board S2 LP (RSB S2 LP) is a PCI board with a completely independent system, i.e. it has its own operating system with Web server and SNMP agents and can optionally be equipped with an external power supply. The RSB permits remote diagnosis for system analysis, remote system configuration and remote restart even in the event of operating system failure or hardware faults. It has its own LAN connection. All the functions of the RSB are available via a LAN.

External SCSI interface

One channel of the on-board SCSI controller can optionally be made available externally.

Parallel interface for printers

As an option, a parallel interface can be provided for printers.

Conversion of SCSI 1-channel version to SCSI 2-channel version

The internal SCSI configuration can be converted from a 1-channel version to a 2-channel version. The hard disk access times are shortened. Use of the 2-channel version together with a RAID controller increases the availability of the system.

Page 62: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Notational conventions Introduction

1.3 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands, menu items or software programs.

„Quotation marks“ indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Table 1: Notational conventions

6 Options Guide U41601-J-Z156-1-76

Page 63: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

2 ProcedureV CAUTION!

The actions described in these instructions should only be performed by technical specialists or service personnel. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.

Ê First of all please familiarize yourself with the safety instructions in the section chapter „Safety notes“ on page 9.

Ê Ensure that all required manuals (see „Additional documentation about the server“ on page 1) are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server and the Technical Manual for the system board.

Ê Shut down the server correctly, switch it off, pull out the power plug, and open the server as described in the chapter „Preparation“ on page 15.

Ê Extend or upgrade your server as described in the relevant chapter.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

Ê Start the operating system and, if necessary, configure it as required (see the Operating Manual).

U41601-J-Z156-1-76 Options Guide 7

Page 64: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 65: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

3 Safety notesI The following safety notes are also provided in the “Safety” manual.

This device complies with the relevant safety regulations for data processing equipment.

If you have any questions about where you can set up the device, contact your sales outlet or our customer service team.

V CAUTION!

The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability.

Before operating the device

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

U41601-J-Z156-1-76 Options Guide 9

Page 66: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

Installation and operation

V CAUTION!

● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

● The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug(s) from the grounded insulated socket(s).

V CAUTION!

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage.

● Data cables to peripheral devices must be adequately shielded.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

10 Options Guide U41601-J-Z156-1-76

Page 67: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug(s) and contact your sales outlet or customer service team.

● Proper operation of the device (in accordance with IEC 60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

V CAUTION!

● The components marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

● You may only set those resolutions and refresh rates specified in the „Technical data“ section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board D1889).

● Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste.

U41601-J-Z156-1-76 Options Guide 11

Page 68: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

● The battery must be disposed of in accordance with local regulations concerning special waste.

● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board D1889.

● All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant:

Cd Cadmium Hg Mercury Pb Lead

Notes on handling CDs and CD-/DVD-ROM drives

V CAUTION!

● Use only CDs in proper condition in the CD-/DVD-ROM drive of your server to prevent data loss, damage to the device and injuries.

● Therefore, check each CD for damage, cracks, breakage etc. before inserting it in the drive.

Please note that any additional labels applied may change the mechanical properties of a CD and cause imbalance.

Damaged and imbalanced CDs can break at high drive speeds (data loss).

Under certain conditions sharp-edged pieces of broken CDs can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck).

I You protect the CD-/DVD-ROM drive and prevent mechanical damage, as well as premature wearing of the CDs, by observing the following suggestions:

– Only insert the CDs in the drive when needed and remove them after use.

– Store the CDs in suitable sleeves.– Protect the CDs from exposure to heat and direct sunlight.

12 Options Guide U41601-J-Z156-1-76

Page 69: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

Note about the laser

The CD-/DVD-ROM drive is classified for laser class 1 according to IEC 60825-1.

V CAUTION!

The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.

Never remove parts of the CD-/DVD-ROM drive assembly!

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug(s) from the power socket(s) before inserting or removing components containing ESDs.

● You must always discharge yourself of static charges (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Only touch the components at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

U41601-J-Z156-1-76 Options Guide 13

Page 70: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Safety notes

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).

14 Options Guide U41601-J-Z156-1-76

Page 71: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

4 PreparationV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

4.1 Removing the server form the rack

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the sever, press the on/off switch.

Ê Pull all power connectors out of the power outlets.

Figure 2: Loosening the knurled screws

Ê Loosen the four knurled screws (1) and pull the server as far as possible out of the rack (2).

2

1

1

U41601-J-Z156-1-76 Options Guide 15

Page 72: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Removing the server form the rack Preparation

Depending on how accessible the server is in the rack cabinet, it can make sense to remove it from the cabinet. If you do not want to remove the server from the rack cabinet, please skip this page.

Figure 3: Removing the server from the rack cabinet

Ê Disconnect all cables on the rear of the server.

Ê Pull the server outward as far as it will go (1), release the hooks (2), then pull out the Server completely.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

1

2

16 Options Guide U41601-J-Z156-1-76

Page 73: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Preparation Opening the server

4.2 Opening the server

Figure 4: Removing the top cover

Ê Pess the two locking buttons (1) downward and remove the cover (2).

Ê Slide the cover to the rear side and remove it (2).

1

12

U41601-J-Z156-1-76 Options Guide 17

Page 74: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 75: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

5 Main memoryV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

The system board supports up to 16 Gbytes of main memory. 8 slots (4 memory banks with 2 slots each) are provided for the main memory. Each memory bank is equipped with two 512-Mbyte, 1-Gbyte or 2-Gbyte registered DDR2 400 (PC2-3200) memory modules.

A memory bank can optionally be configured as a hot-spare bank.

As memory bank 3 is already equipped either with 1-Gbyte, 2-Gbyte or4-Gbyte of memory in the basic unit, up to 3 memory upgrades can be fitted, one to each banks 2, 1 and 0.

ECC with memory scrubbing and with the Single Device Data Correction (SDDC, Chipkill) function is standard.

5.1 Memory module population

Figure 5: Structure of the main memory in memory banks and memory modules

– The memory modules have to be based on x4 organized SDRAM and must be populated in pairs

Memory bank 0 - DIMM-0A

Memory bank 0 - DIMM-0B

Memory bank 1 - DIMM-1A

Memory bank 1 - DIMM-1B

Memory bank 2 - DIMM-2A

Memory bank 2 - DIMM-2B

Memory bank 3 - DIMM-3A

Memory bank 3 - DIMM-3B

U41601-J-Z156-1-76 Options Guide 19

Page 76: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Memory module population Main memory

– Each pair must consist of identical memory modules (2-way Interleaved-mode).

– The memory module capacity can differ for the various memory banks: e.g. memory bank 0A/0B can be equipped with two 512-Mbyte memory modules, and memory bank 1A/1B with two 1-Gbyte memory modules.

– Only single ranked modules are permitted.

The following table shows the required memory population sequence:

Memory mirroring

Either 4 or 8 identical memory modules are required for memory mirroring:

DIMM-3A/DIMM-3B DIMM-2A/DIMM-2B DIMM-1A/DIMM-1B DIMM-0A/DIMM-0B

populated empty empty empty

populated populated empty empty

populated populated populated empty

populated populated populated populated

Memory bank

3 2 1 0

Channel (module)

A B A B A B A B

population 4 identical memory modules - -

4 identical memory modules 4 identical memory modules

20 Options Guide U41601-J-Z156-1-76

Page 77: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Main memory Memory module population

Figure 6: Diagram Memory Mirroring

I For more information see BIOS-Setup manual (see chapter „Related publications“ auf Seite 109).

� Supported for 8 DIMMs of DDR2-400 ( PC2-3200 )� The diagonal mirroring implementation shown below allows bandwidth on

both channels to be fully utilized during normal operation� Every write to memory is issued twice, one to primary location, and again to

mirror location� Memory has two full copies of all data and a complete copy on each channel

� System Requirements� 4 DIMMs with completely identical devices in slots 3 & 4 on each channel� 4 DIMMs with completely identical devices in slots 1 & 2 on each channel

Lindenhurst MCH

DIMM

A1

DIMM

A2

DIMM

A3

DIMM

A4

D IMM

B 1

D IMM

B 2

D IMM

B 3

D IMM

B 4

Channel A

Channel B

Memory Subsystem

Mirror Mirror PrimaryPrimary

Memory Mirroring with 4 or 8 DIMMs

DIM

M A3

DIMM

B3D

IMM

B2

DIMM

A3D

IMM

B 3

DIM

M A2

DIM

M A4

DIM

M B4

U41601-J-Z156-1-76 Options Guide 21

Page 78: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Upgrading/replacing the main memory Main memory

5.2 Upgrading/replacing the main memory

Ê Open the server as described in the chapter „Safety notes“ on page 9.

Removing the air duct over the main memory and the processors

Figure 7: Removing the air duct over the main memory and the processors

Ê Lift out the air duct over the main memory.

22 Options Guide U41601-J-Z156-1-76

Page 79: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Main memory Upgrading/replacing the main memory

Figure 8: populating memory module slots

Figure 9: Removing a memory module

Ê Press the holders on either side of the mounting location concerned outward (1).

Ê Pull the memory module out of the mounting location (2).

1

12

U41601-J-Z156-1-76 Options Guide 23

Page 80: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Upgrading/replacing the main memory Main memory

Figure 10: Inserting a memory module

Ê Press the holders on either side of the mounting location concerned outward.

Ê Insert the memory module in the mounting location (1) until the holders at the sides engage (2).

2

2

24 Options Guide U41601-J-Z156-1-76

Page 81: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Main memory Upgrading/replacing the main memory

Inserting air duct

Figure 11: Installing the air duct over the memory and processors

Ê Reinstall the air duct over the system fans.

V CAUTION!

Ensure that no damage is caused to the cables!

U41601-J-Z156-1-76 Options Guide 25

Page 82: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Upgrading/replacing the main memory Main memory

Figure 12: Guiding edge between the air duct and fanbox

Figure 13: Support point of the air duct.

Ê Pay attention to the guiding edge between the air duct and the fan box (1) and ensure a correct fit, especially at the places (2, 3 and 4).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

1

2

3 4

26 Options Guide U41601-J-Z156-1-76

Page 83: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

6 ProcessorsV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

V CAUTION!

Processors are modules which can react extremely sensitively to electro-static discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never push a processor over a surface.

6.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor, and a heat sink.

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor. For dual operation, use a suitable multipro-cessor operating system.

Ê Open the server as described in the chapter „Preparation“ on page 15.

Ê Remove the air duct over the main memory (see chapter „Main memory“ on page 19).

U41601-J-Z156-1-76 Options Guide 27

Page 84: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a second processor Processors

Figure 14: Removing processor dummy module

Ê Pull the processor dummy out.

V CAUTION!

Keep the dummy cover for future use. If you remove the processor again and do not replace it with a new one, reinstall the dummy cover to ensure that the system is cooled properly.

28 Options Guide U41601-J-Z156-1-76

Page 85: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Processors Installing a second processor

Figure 15: Empty processor slot

Ê Release the socket lifter by pressing it sideways and pull it upward as far as it will go.

Figure 16: Inserting processor

1

2

U41601-J-Z156-1-76 Options Guide 29

Page 86: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a second processor Processors

Ê Position the new processor over the socket and then carefully press it into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners. To avoid damaging the pins or the processor, do not force it into the socket.

Ê Lock the processor in the socket by returning the socket lifter to its original position (2).

Ê Remove the protective cover on the underside of the heat sink.

Figure 17: places of the springs round the heat sink support pins

Ê Check whether the springs round the heat sink support pins are aligned centrally.

30 Options Guide U41601-J-Z156-1-76

Page 87: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Processors Installing a second processor

Figure 18: Installing heat sink

Ê Place the heat sink on the processor.

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

V CAUTION!

Never install a processor without a heat sink as otherwise the processor may overheat, causing a shut-down of the system.

Ê Reinstall the ventilation duct over the system fans see chapter „Main memory“ on page 19.

V CAUTION!

Ensure a correct fit of the airduct and that no damage is caused to the cables

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 31

Page 88: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the processor Processors

6.2 Replacing the processor

V CAUTION

Only processors of the same type may be used on the system board. The second processor must have the same clock frequency and the same cache as the first processor. For dual operation, use a suitable multipro-cessor operating system.

Ê Open the server as described in the chapter „Preparation“ on page 15.

Ê Remove the air duct over the main memory and the processors (see page 22.

Figure 19: Removing the heat sink

Ê Loosen the four screws in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

32 Options Guide U41601-J-Z156-1-76

Page 89: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Processors Replacing the processor

Figure 20: Removing an installed processor

Ê Release the socket lifter by pressing it sideways and pull it upward as far as it will go (1).

Ê Lift the installed processor carefully out of the socket (2).

2

1

U41601-J-Z156-1-76 Options Guide 33

Page 90: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Replacing the processor Processors

Figure 21: Inserting a new processor

Ê Position the new processor over the socket and then carefully press it into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners (2). To avoid damaging the pins or the processor, do not force it into the socket.

Ê Lock the processor in place in the socket by returning the socket lifter to its original position (3).

Ê Remove the protective cover on the underside of the heat sink.Do not touche the pad.

Ê Place the heat sink on the processor socket (see page 31).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinstall the air duct over the main memory and the processors (see „Inserting air duct“ on page 25).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

1

2

3

34 Options Guide U41601-J-Z156-1-76

Page 91: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

7 ROMB (RAID on Motherboard)V CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

The on-board SCSI controller can be upgraded to a RAID5 (RAID 0, 1, 5, 10, 50) controller with a "MegaRaid PCI Express™ ROMB" upgrade kit. In this case the on-board INTEL I/O processor is activated by installing a license key and a cache module.

Two different upgrade kits are offered:

– Upgrade kit S26361-F3091-E128, consisting of an iButton license key and a 256 MB cache module.

– Upgrade kit S26361-F3091-E328, consisting of an iButton license key and a 128 MB cache module with a battery also integrated on the module (iTBBU=integrated Transportable Battery Backup Unit).

7.1 Installing the ROMB upgrade kit

Ê Open the server as described in the chapter „Preparation“ on page 15.

Figure 22: Cache module (with battery) and iButton

I Only for cache module with battery.

Ê Remove the screw (1) on the battery and connect the cable (2) on the module.

12

U41601-J-Z156-1-76 Options Guide 35

Page 92: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the ROMB upgrade kit ROMB (RAID on Motherboard)

Figure 23: Installing the iButton and the Cache module

Ê Install the iButton on the system board (1).

Ê Press the holders on either side of the mounting location outward.

Ê Insert the cache module.

Ê Press the cache module downward until the holders on either side of the mounting location are engaged.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

I Information on the configuration is provided in the Technical Manual for the system board.

1

36 Options Guide U41601-J-Z156-1-76

Page 93: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

8 Accessible drivesV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

I Two free bays are available for accessible drives. One 3,5 Inch x 0,5 Inch is for a FD drive and one 5,25 inch x 0,5 inch is for a CD/DVD-ROM drive available. A local view module can also be installed Into the upper bay (FD drive).

V CAUTION!

For installing a FD drive or a CD-/DVD drive frames and cables are necessary.

U41601-J-Z156-1-76 Options Guide 37

Page 94: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a FD drive Accessible drives

8.1 Installing a FD drive

Ê Open the server as described in the chapter „Preparation“ on page 15.

Removing a FD drive dummy module

Figure 24: Unlocking the FD drive dummy module

Ê Unlock the FD drive dummy module (1).

Ê Push the FD drive dummy module to the front (2).

1

2

38 Options Guide U41601-J-Z156-1-76

Page 95: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing a FD drive

Figure 25: Removing dummy module

Ê Pull the FD drive dummy module out to the front side.

V CAUTION!

Keep the dummy module for future use. If you remove the FD drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

U41601-J-Z156-1-76 Options Guide 39

Page 96: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a FD drive Accessible drives

Installing FD drive

Figure 26: Insert FD drive into the mounting frame.

I The mouning frame and the cable is deliverd in the accessory pack with the PRIMERGY RX300 S2.

Ê Insert the FD drive into the mounting frame. Regard the plastic pins. They fix the dive in the frame.

Ê Connect the cable.

40 Options Guide U41601-J-Z156-1-76

Page 97: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing a FD drive

Figure 27: Inserting FD drive module

Ê Thread the flat cable in the bay.

Ê Push the FD drive module into the bay, until it locks.

U41601-J-Z156-1-76 Options Guide 41

Page 98: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a FD drive Accessible drives

Figure 28: Connecting FD drive cable

Ê Connect the FD cable to the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

42 Options Guide U41601-J-Z156-1-76

Page 99: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing a LocalView module

8.2 Installing a LocalView module

The LocalView module is an optional extra for the servers of the PRIMERGY series. On the display panel of the LocalView module you can read status messages directly on the server. These status messages provide information on the system and notify you of hardware faults (e.g. fan failure, CPU over voltage, etc.).

The LocalView module can be pulled out like a sliding drawer. You can also angle the LocalView display panel downward.

The LocalView module can be installed in the 3,5/0,5 inch bay of the FD drive.

Figure 29: LocalView module

Ê Open the server as described in the chapter „Preparation“ on page 15.

Ê If a FD dummy module is installed it must be removed (see „Removing a FD drive dummy module“ on page 38).

U41601-J-Z156-1-76 Options Guide 43

Page 100: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a LocalView module Accessible drives

Removing the FD Drive

Figure 30: Unlocking the the FD Drive module (for better visibility, the fanbox is removed)

Ê Unlock (1) the FDD module.

Ê Push the FDD module to the front (2).

1

2

44 Options Guide U41601-J-Z156-1-76

Page 101: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing a LocalView module

Figure 31: Removing FD drive cable

Ê Remove the FD drive cable from the system board.

U41601-J-Z156-1-76 Options Guide 45

Page 102: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a LocalView module Accessible drives

Figure 32: Removing FD-Drive module

Ê Pull the FD drive module out. to the front side.

46 Options Guide U41601-J-Z156-1-76

Page 103: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing a LocalView module

Figure 33: Threading the cable (for better visibility, the fanbox is removed)

Ê Push the cable for the LocalView module through the bay to the front.

U41601-J-Z156-1-76 Options Guide 47

Page 104: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a LocalView module Accessible drives

Figure 34: Connecting the cable to the LocalView module

Ê Connect the cable to the LocalView module.

48 Options Guide U41601-J-Z156-1-76

Page 105: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing a LocalView module

Figure 35: Inserting the LocalView module

Ê Slide the LocalView module into the mounting location until it latches in place.

I Further information on operation and display modes is provided in the documentation for the LocalView module.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 49

Page 106: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the CD/ DVD-ROM drive Accessible drives

8.3 Installing the CD/ DVD-ROM drive

Ê Open the server as described in the chapter „Preparation“ on page 15.

Removing the CD/DVD drive dummy module

Figure 36: Unlocking the CD/DVD drive dummy module

Ê Unlock (1) the CD/DVD drive dummy module.

Ê Push the FDD module to the front (2).

1

2

50 Options Guide U41601-J-Z156-1-76

Page 107: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing the CD/ DVD-ROM drive

Figure 37: Removing dummy module

Ê Remove the dummy module.

V CAUTION!

Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

U41601-J-Z156-1-76 Options Guide 51

Page 108: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the CD/ DVD-ROM drive Accessible drives

Figure 38: Installing the CD/DVD drive into its mounting frame

Ê Install the CD/DVD Drive in the mounting frame (the mounting frame is delivered with the drive, and the IDE cable is included to the assessory pack of the server. Regard the plastic pins which fix the drive in the frame.

Figure 39: Connecting the CD/DVD drive cables

1

52 Options Guide U41601-J-Z156-1-76

Page 109: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Accessible drives Installing the CD/ DVD-ROM drive

Ê Thread the power cable (1) through the bay and connect it to the CD Drive (see also chapter „Appendix“ on page 103).

Ê Connect the IDE cable to the drive (see also chapter „Appendix“ on page 103)

Figure 40: Pushing the CD/DVD drive into the bay

Ê Push the drive into the bay completely.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 53

Page 110: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 111: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

9 PCI slotsV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

Standard configuration

The system board offers five PCI slots. Slots 1-3 are non-hot-plug PCI slots . If two or three slots are occupied, the bus speed is 100 MHz, but, if only slot 3 is occupied IOOP™ rules allow this slot to operate at 133 MHz.

I The PCI slot 4 and 5 are hot-plug slots, that can be equipped with hot-plug RAID controllers. You will find the description of the hot-plug slots in the users manual.

Optional configuration with riser card

Three standard slots are available with a riser card: 1 x PCI-X 64-bit/100 MHz, long, standard height; 2 x PCI-X 64-bit/100 MHz, short, standard height.

U41601-J-Z156-1-76 Options Guide 55

Page 112: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a PCI controller in a low-profile slot PCI slots

9.1 Installing a PCI controller in a low-profile slot

Ê Open the server as described in the chapter „Preparation“ on page 15.

Figure 41: Remove the slot cover

Ê Push the green PCI board holder toward the rear (1).

Ê Remove the slot cover of the PCI slot (2).

V CAUTION

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

1

2

56 Options Guide U41601-J-Z156-1-76

Page 113: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

PCI slots Installing a PCI controller in a low-profile slot

Figure 42: Inserting controller

Ê Install the controller in the PCI slot and press it carefully into the associated plug-in location on the system board (1). Ensure that the rear cover fits into the recesses (a).

Ê Close the green PCI board holder (2).

Ê If required, connect the cables to the controller and other components.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

a

a

12

U41601-J-Z156-1-76 Options Guide 57

Page 114: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the PCI controller in the riser card PCI slots

9.2 Installing the PCI controller in the riser card

Ê Open the server as described in the chapter „Preparation“ on page 15.

Figure 43: Removing the riser card

Ê Open the knurled screws.

V CAUTION!!

Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

58 Options Guide U41601-J-Z156-1-76

Page 115: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

PCI slots Installing the PCI controller in the riser card

Figure 44: Removing the riser card

Ê Remove the riser card upward.

Figure 45: Installing the controller

U41601-J-Z156-1-76 Options Guide 59

Page 116: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the PCI controller in the riser card PCI slots

Ê Remove the screw and the slot cover of the associated connector

I To equip slot 8 with a full-length PCI controller it is necessary to remove slot cover of slot 7 too.

Figure 46: Installing controller

Ê Insert the controller into the PCI slot and push it down carefully.

Ê Fix the slot cover/s with the screw/s.

Ê If necessary connect the cables to the controller or other components.

Ê Insert the riser card and be careful with the cables.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

60 Options Guide U41601-J-Z156-1-76

Page 117: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

PCI slots Population of the PCI slots

9.3 Population of the PCI slots

Standard configuration with 5 low profile slots

Riser configuration with 3 standard profile slots

Adapter class Adapter priority Slot (order)

External SCSI interface 1 1

Parallel port 2 5

FC (QLA2340, LP9802) 3 5, 4

RSB 4 3, 4, 5

LAN Controller 5 5, 4, 3, 2, 1

RAID 6 5, 4, 3, 2, 1

SCSI 7 5, 4, 3, 2, 1

Adapter class Adapter priority Slot (order)

External SCSI interface 1 6

Parallel Port 2 8

RAID 3 8, 7, 6

FC (QLA2340, LP9802) 3 7, 6

RSB 4 6, 7, 8

LAN Controller 5 7, 6

SCSI 7 7, 6

U41601-J-Z156-1-76 Options Guide 61

Page 118: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 119: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

10 RemoteView componentsV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

10.1 Installing the chipDISK

Ê Open the server as described in the chapter „Preparation“ on page 15.

Figure 47: Installing the chipDISK

Ê Connect the chipDISK to the plug-in location on the system board.

V CAUTION

Note the coding of the chipDISK and plug-in location.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 63

Page 120: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

RemoteView Service Board S2 LP RemoteView components

10.2 RemoteView Service Board S2 LP

I How to install/remove and configure the RSB S2 LP is described in detail in the “RemoteView Service Board S2/ S2 LP 1.x, Mounting and Setting Up” manual.

Preferred mounting locations for RSB S2 LP are PCI slots 3, 4, and 5 in the standard configuration with only low profile PCI Slots. To configure ther RSB with a riser card you have to use RSB S2 LP 3HU. Any of the three slots can be used.

Ê Open the server as described in the chapter „Preparation“ on page 15.

Figure 48: Connecting cables to the system board

Ê Connect the data cable to the connector IPMB (1) and the power cable to the connector KVM Power (2) on the system board.

Figure 49: Connecting cables to the system board

Ausschnitt /section of D1889

1 2

2

1

64 Options Guide U41601-J-Z156-1-76

Page 121: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

RemoteView components RemoteView Service Board S2 LP

Ê Connect the power cable (1) and the data cable (2) to the RSB S2 LP.

Ê Install the RSB S2 LP into PCI slot 3, 4 or 5 (described in „Installing a PCI controller in a low-profile slot“ on page 56) and RSB S2 LP 3 HU into PCI slot 6, 7or 8 (described in „Installing the PCI controller in the riser card“ on page 58) respectively.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 65

Page 122: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 123: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

11 External SCSI interfaceV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

11.1 Installing the external SCSI interface

Ê Open the server as described in the chapter „Preparation“ on page 15.

I For standard configuration the external SCSI interface is to install with a low profile slot cover. If the optional riser card is used, a standard slot cover is necessary.

External SCSI interface in standard configuration

Figure 50: external SCSI cable with low-profile slot cover.

U41601-J-Z156-1-76 Options Guide 67

Page 124: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the external SCSI interface External SCSI interface

Removing fan box

Figure 51: Unlocking fan box air duct

Ê Unlock the fan box air duct.

Figure 52: Removing fan box air duct

Ê Pull the fan box air duct out.

68 Options Guide U41601-J-Z156-1-76

Page 125: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

External SCSI interface Installing the external SCSI interface

Figure 53: Removing the fan box

Ê Unlock all fans (1).

Ê Unlock the fan box (2).

Ê Push the fan box to the left side (3).

Ê Pull out the fan box in an angle (4).

1 1 1 12

3

4

U41601-J-Z156-1-76 Options Guide 69

Page 126: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the external SCSI interface External SCSI interface

Removing cable channel cover

Figure 54: Remove the three-part cable channel cover.

Figure 55: Snap-fits of the three-part cable channel cover

Ê Remove the three-part cable channel. Press the upper and lower snap-fit on the outside together. Each part of the three-part cable chanel coverhas two snap-fits.

Ê Push the green PCI board holder of slot 1 backward.

Ê Remove the slot cover.

viewoutside

viewinside

70 Options Guide U41601-J-Z156-1-76

Page 127: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

External SCSI interface Installing the external SCSI interface

Figure 56: Installing cable

Ê Insert the slot cover with the SCSI interface.

Ê Close the green PCI board holder.

Ê Route the SCSI cable, as shown in the picture.

Ê Insert the three-part cable channel cover.

U41601-J-Z156-1-76 Options Guide 71

Page 128: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the external SCSI interface External SCSI interface

Figure 57: Connecting the SCSI cable to the system board

Ê Connect the SCSI cable to the connector SCSI B on the system board (see arrow).

Ê Install the fan box and the fan box air duct.

Ê Push the fans back.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

72 Options Guide U41601-J-Z156-1-76

Page 129: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

External SCSI interface Installing the external SCSI interface

External SCSI interface in the riser card

Figure 58: Cable for external SCSI interface (with low profile slot cover)

Ê Remove the two screws.

Ê Remove the low-profile slot cover from the SCSI-connector.

Figure 59: External. SCSI Interface with standard slot cover

Ê Insert the SCSI connector to the slot cover.

U41601-J-Z156-1-76 Options Guide 73

Page 130: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the external SCSI interface External SCSI interface

Figure 60: Removing riser card

Ê Remove the riser card.

Figure 61: Removing slot cover of slot 6

Ê Remove the screw of the slot cover of slot 6.

Ê Remove the slot cover of slot 6.

Ê Remove the fan box, see „Removing fan box“ on page 68.

74 Options Guide U41601-J-Z156-1-76

Page 131: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

External SCSI interface Installing the external SCSI interface

Figure 62: opening cable duct

Ê Open the cabel channel cover, see „Removing cable channel cover“ on page 70.

Figure 63: external SCSI interface

Ê Thread the cable in the cable channel.

V CAUTION

Leave an extra 6 cm cable protruding.

Ê Close the cable duct.

U41601-J-Z156-1-76 Options Guide 75

Page 132: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing the external SCSI interface External SCSI interface

Figure 64: Inserting riser card

Ê Lay the riser card into the server as shown above.

Ê Push the SCSI slot cover into Slot 6.

Ê Fix the slot cover with the screw.

Ê Insert the riser card completely.

Ê Fix the riser card with the two knurled screws.

76 Options Guide U41601-J-Z156-1-76

Page 133: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

External SCSI interface Installing the external SCSI interface

Figure 65: Connecting the external SCSI cable to the system board

Ê Connect the SCSI cable to the connector SCSI B on the system board (see arrow).

Ê Insert the fan box and the fan box air duct.

Ê Press the fans firmly into position.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 77

Page 134: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 135: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

12 Parallel interfaceV CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

12.1 Installing a parallel interface

Ê Open the server as described in the chapter „Preparation“ on page 15.

I For standard configuration the parallel interface is to install into a low-profile slot cover. If the optional riser board is used, a standard slot cover is necessary.

Parallel interface in standard configuration

Figure 66: external parallel interface with low-profile slot cover

U41601-J-Z156-1-76 Options Guide 79

Page 136: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a parallel interface Parallel interface

Figure 67: Removing the slot cover

Ê Push the PCI board holder backward.

Ê Remove the slot cover.

Figure 68: Routing the cable

Ê Insert the slot cover with the parallel interface.

Ê Connect the cable to the system board (see arrow).

Ê Route the cable as shown in the picture directly upon the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

80 Options Guide U41601-J-Z156-1-76

Page 137: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Parallel interface Installing a parallel interface

External Parallel-interface in slot cover with standard height

Figure 69: External parallel interface with low-profile slot cover

Ê Remove the two screws.

Figure 70: External parallel interface with standard slot cover

Ê Insert the connector of the parallel interface in the slot cover.

Ê Fix it with the two screws.

U41601-J-Z156-1-76 Options Guide 81

Page 138: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a parallel interface Parallel interface

Figure 71: Removing the riser card

Ê Remove the riser card.

Figure 72: Removing the slot cover of slot 8

Ê Remove the slot cover of slot 8.

82 Options Guide U41601-J-Z156-1-76

Page 139: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Parallel interface Installing a parallel interface

Figure 73: Installing the slot cover with the connector of the parallel interface.

Ê Insert the slot cover with the parallel interface in slot 8 and fix the slot cover with the screw.

Ê Thread the flat cable between the riser board and the plastic side cover.

I Route the cable as shown in the photo.

U41601-J-Z156-1-76 Options Guide 83

Page 140: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing a parallel interface Parallel interface

Figure 74: Installing the riser card with parallel interface.

Ê Insert the riser card.

Ê Route the cable.

Ê Connect the cable to the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

84 Options Guide U41601-J-Z156-1-76

Page 141: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

13 Converting from 1- to 2-channel version

V CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

I For the PRIMERGY RX300 S2 the SCSI backplane is separated into two parts. The 1st SCSI backplane can stay installed for both configurations. For upgrading you must change the second SCSI backplane. Die 1-channel backplane must be exchanged for a 2-channel SCSI backplane (which is the same as the SCSI backplane installed in the first SCSI backplane holder yet) and the SCSI cabling must be exchanged.

Figure 75: Second SCSI backplane for 1-channel configuration

U41601-J-Z156-1-76 Options Guide 85

Page 142: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Converting from 1- to 2-channel version

Figure 76: Second SCSI backplane 2-channel configuration (backplane is equal to the first SCSI backplane).

86 Options Guide U41601-J-Z156-1-76

Page 143: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Converting from 1- to 2-channel version Removing 2nd SCSI backplane

13.1 Removing 2nd SCSI backplane

Ê Open the server as described in the chapter „Preparation“ on page 15.

Ê Remove all hot-plug hard disks or/and the hot-plug tape drive on the left side (for a description see the Operating Manual).

Figure 77: Disconnecting the cables

Ê Pull out the connectors of the I2C cable (1), the power cable (2), and both SCSI cables (3) from the SCSI backplane.

1

2

3

3

U41601-J-Z156-1-76 Options Guide 87

Page 144: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Removing 2nd SCSI backplane Converting from 1- to 2-channel version

Figure 78: Loosening knurled screw

Ê Loosen the knurled screw.

Ê Twist the SCSI backplane holder out slightly. Do not damage the hooks.

Ê Pull the SCSI backplane holder out.

88 Options Guide U41601-J-Z156-1-76

Page 145: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Converting from 1- to 2-channel version Removing 2nd SCSI backplane

Figure 79: Removing the 2nd SCSI backplane (1-channel) from the holder

Ê Unlock the backplane from the snap-fits.

Ê Remove the SCSI backplane from the holder.

U41601-J-Z156-1-76 Options Guide 89

Page 146: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing 2nd SCSI backplane Converting from 1- to 2-channel version

13.2 Installing 2nd SCSI backplane

Figure 80: Inserting the 2nd SCSI backplane (2-channel) into the SCSI backplane holder

Ê Insert the 2-channel SCSI backplane in the hooks of the SCSI backplane holder (1).

Ê Press the SCSI backplane down.

Ê The backplane must engage under the green snap-fits (2).

1

2

90 Options Guide U41601-J-Z156-1-76

Page 147: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Converting from 1- to 2-channel version Installing 2nd SCSI backplane

Figure 81: Inserting second SCSI backplane

Ê Insert the assembled SCSI backplane holder. Be careful with the hooks. The angle may not be too great.

Ê Close the holder.

Ê Fasten it with the knurled screw.

U41601-J-Z156-1-76 Options Guide 91

Page 148: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing 2nd SCSI backplane Converting from 1- to 2-channel version

Figure 82: Cabling the second SCSI backplane

Ê Connect the I2C cable (1), the power cable (2) and the SCSI-cable (3) to the SCSI backplane.

I Do not insert the SCSI signal cable.

Ê Connect the SCSI cable to (4) and (5) of the system board.

Ê Reinstall the fan box and the fan box air duct.

Ê Reinstall the drives.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

2 3

4

1

5

92 Options Guide U41601-J-Z156-1-76

Page 149: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

14 Converting from low-profile to standard PCI Slots

V CAUTION!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

14.1 Removing lp slot cage

Ê Open the server as described in the chapter „Preparation“ on page 15.

Figure 83: Removing hot-plug cable

Ê Release and remove the hot-plug cable from the system board.

U41601-J-Z156-1-76 Options Guide 93

Page 150: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Removing lp slot cage Converting from low-profile to standard PCI Slots

Figure 84: Removing the slot cage

Ê Remove the two screws.

Ê Pull the slot cage out.

94 Options Guide U41601-J-Z156-1-76

Page 151: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Converting from low-profile to standard PCI Slots Removing lp slot cage

Figure 85: Without slot cage

Ê Equip the riser card as described in part „Installing the PCI controller in the riser card“ on page 58.

Figure 86: Assembled Riser card

U41601-J-Z156-1-76 Options Guide 95

Page 152: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Installing Riser card Converting from low-profile to standard PCI Slots

14.2 Installing Riser card

Figure 87: Inserting the Riser card

Ê Install the riser card.

96 Options Guide U41601-J-Z156-1-76

Page 153: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Converting from low-profile to standard PCI Slots Installing Riser card

Figure 88: With riser card

Ê Fasten the two screws.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter „Completion“ on page 99.

U41601-J-Z156-1-76 Options Guide 97

Page 154: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 155: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

15 CompletionV CAUTION!!

Observe the safety instructions in the chapter „Safety notes“ on page 9.

15.1 Closing the server

Figure 89: Closing the cover

Ê Apply the cover.

Ê Push the cover to the front (1).

Ê Make sure that the locks engage.

1

1

U41601-J-Z156-1-76 Options Guide 99

Page 156: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Closing the server Completion

If you have not removed the server from the rack cabinet, please skip this page.

Figure 90: Installing the server in a rack cabinet

V CAUTION!

At least two people are required to install the server in the rack cabinet.Do not use the handles on the rack front cover to lift the server into the rack.

Ê Lower the server from above onto the extended telescopic rails.

Ê Push the server in the direction of the arrow (1) until the hooks of the telescopic rails engage.

Ê Release the telescopic rails’ locking mechanism (2) on both sides and push the server as far as it will go into the rack.

Ê Reconnect all the cables you disconnected beforehand on the rear of the server.

2

1

100 Options Guide U41601-J-Z156-1-76

Page 157: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Completion Closing the server

Figure 91: Fastening the knurled screws

Ê Fasten the server in the rack using the two knurled screws (1).

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

2

1

1

U41601-J-Z156-1-76 Options Guide 101

Page 158: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 159: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

16 Appendix

16.1 Cabling

The following table gives you an overview of the cables:

Numbers in the drawings

Material number Designation

1 A3C40058008 Parallel Port cable

2 A3C40057192 SV cable PSU

3 A3C40057188 SV cable 24 pol

4 T26139-Y3697-V101 Power Backplane SMB cable

5 A3C40058003 Power cable CD-ROM

6 A3C40057191 SV cable PSU

7 A3C40057185 USB FRONTPANEL cable

8 A3C40057190 OPERATER PANEL cable

9 A3C40057187 ULTRA ATA cable

10 A3C40057186 FLEX FLAT cable

11 A3C40057385 SMB CABLE

12 A3C40058005 SCSI cable

13 A3C40057189 SCSI CTRL.CABLE

14 A3C40058004 SCSI cable

15 A3C40057182 FLEX FLAT CABLE

U41601-J-Z156-1-76 Options Guide 103

Page 160: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Cabling Appendix

Figure 92: Basic cabling with 1-channel SCSI

Fron

tpan

el

Loca

lVi

ewSCS

I-HD

ID2

SCS

I-HD

ID1

SCS

I-HD

ID0

SCS

I-HD

ID2

SCS

I-HD

ID1

SCS

I-HD

ID0

1" H

DD

SCSI

PowerLegend:

IDTE

MP

Com

bo

CD

-RO

M S

limlin

e

Flop

py S

limlin

e

PS Bpl

1" H

DD

Verkabelung RX300 S2 mit 1 Kanal SCSI

USB

BPL 0BPL 1

SMBusSCSIIDE/FDUSBSteuersignal

13

Power

SupplyR

SP-500

Power

SupplyR

SP-500

optionalerparallel Port

SCSI

System FAN

System FANredundant

CPU FAN3

CPU FAN3redundant

CPU FAN2 CPU FAN1

CPU FAN2redundant

CPU FAN1redundant

CPU1 CPU0D

IMM

3B

DIM

M 3

AD

IMM

2B

DIM

M 2

AD

IMM

1B

DIM

M 1

A

PCI S

lot

1

PCI S

lot

2

PCI S

lot

3

PCI S

lot 4

hot

plu

g

PCI S

lot 5

hot

plu

g

Com

pact

Flas

h

SCSI B SCSI A Floppy

Para

llel

12V1

Mai

n Po

wer

PC98

PanelIDEUSB

SMB

hot p

lug

hot p

lug

15

11 10 9 8 7

6

5

2

3

4

1

SCSI

14

12

DIM

M 0

BD

IMM

0A

104 Options Guide U41601-J-Z156-1-76

Page 161: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Appendix Cabling

Figure 93: Basic cabling with 2-channel-SCSI

Fron

tpan

el

Loca

lV

iewSC

SI-H

D ID

2

SCSI

-HD

ID1

SCSI

-HD

ID0

SCSI

-HD

ID2

SCSI

-HD

ID1

SCSI

-HD

ID0

1" H

DD

SCSI

PowerLegend:

IDTE

MP

Com

bo

CD

-RO

M S

limlin

e

Flop

py S

limlin

e

SCSI

PS Bpl

1" H

DD

Verkabelung RX300 S2 mit 2 Kanal SCSI

US

B

BPL 0BPL 1

SMBusSCSIIDE/FDUSBSteuersignal

Pow

erS

upplyR

SP

-500

Pow

erS

upplyR

SP

-500 optionalerparallel Port

SCSI

System FAN

System FANredundant

CPU FAN3

CPU FAN3redundant

CPU FAN2 CPU FAN1

CPU FAN2redundant

CPU FAN1redundant

CPU1 CPU0

DIM

M 3

BD

IMM

3A

DIM

M 2

BD

IMM

2A

DIM

M 1

BD

IMM

1A

PC

I Slo

t 1

PC

I Slo

t 2

PC

I Slo

t 3

PC

I Slo

t 4 h

ot p

lug

PC

I Slo

t 5 h

ot p

lug

Com

pact

Flas

h

SCSI B SCSI A Floppy

Par

alle

l12

V1

Mai

n P

ower

PC

98

PanelIDEUSB

SM

B

hot p

lug

hot p

lug

15

11 10 9 8 7

6

5

2

3

4

1

1412

DIM

M 0

BD

IMM

0A

U41601-J-Z156-1-76 Options Guide 105

Page 162: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Configuration diagram Appendix

16.2 Configuration diagram

Figure 94: part1 of the system configurator

board front sidemiddle

Bank I (2 Modules) Bay for LocalView LCDXeon DP or 3.5"x 0,5" Floppy disk

Bank II (2 Modules)

Bank III (2 Modules) Air channelXeon DP

Bank IV (2 Modules) Bay for 5,25"x 0,5" IDE-CD

or DVD-ROM Memory ( III ) Processor ( II )

Accessible drives ( V )rear side

Fan 1 - Fan 4 1. PSU 2. PSU Needs space for 2

hard disk drives!Fan 5 - Fan 8 3.5"x1,6"

Redundant system- Redundant power fans option Backup drive option supply option

Hard disk drives ( VI ) RAID 5 support Licence key + 128MB Cache channel 1 left side

onboard Licence key + 128MB Cache+BBU

Extension slots for 3.5"x1" ID 5

SCSI Controller ( VII )Disk Array ( VIII )Communication/Network ( IX ) 3.5"x1" ID 4Miscellaneous ( X )

HOT PLUG RISER optionSlot 5: PCI-X 64-Bit / 133MHz, Low Profile 3.5"x1" ID 3

Slot 6: Slot 7: Slot 8:HOT PLUG Standard configuration is

Slot 4: PCI-X 64-Bit / 133MHz, Low Profile single channelchannel 2 (optional) right side

PCI-X 64 PCI-X 64 PCI-X 64

133MHz with IOOP�Slot 3: PCI-X 64-Bit / 100MHz, Low Profile 3.5"x1" ID 2

100 MHz 100 MHz 100 MHz

Slot 2: PCI-X 64-Bit / 100MHz, Low Profile 3.5"x1" ID 1

Standard Standard Standard

Slot 1: PCI-X 64-Bit / 100MHz, Low Profile 3.5"x1" ID 0

short short long

Key:

Included in basic unit

Option

PCI-B

us

2nd

All

low

pro

file

slot

s ar

e co

vere

d, if

PC

I-ris

er c

ard

conf

igur

ed

3rd

1st

1st

1st

106 Options Guide U41601-J-Z156-1-76

Page 163: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Appendix Hard disk mirroring

16.3 Hard disk mirroring

Figure 95: part of the system configurator

The system is equipped with a two channel Utra 320 SCSI on-board controller and embedded "IME".IME (Integrated Mirroring Enhanced) offers the RAID levels 1, 1E witout any additional costs.IME is a RAID 1 implementation ( no RAID 0 support ), which also can operate with an odd number of hard disks( max. 1 RAID 1 set ). Up to 6 hard disks including one hot spare HD are possible depending on the system. Administration of IME is possible with the LSI Global Array Manager (GAM). Windows2000/2003 as well as SuSe and RedHat Linux are supported ( Restrictions refer to Software Configurator )

Example with 3 HD`s:

1-channel standard SCSI-cabling of a basic unit PRIMERGY RX300 S2 with on-board controller1. One channel of the Ultra 320 SCSI controller is connected to the 6 internal hard disks, if no additional HD controllers are configured for internal HDs. (Two backplanes with 3 HDs each cascaded to one SCSI channel with 6HD`s = standard cabling).2. The second channel of the Ultra 320 SCSI controller is available for external accessible SCSI drives with S26361-F3120-E12-channel SCSI cabling of a PRIMERGY RX300 S2 basic unit with on-board controller and "Conversion kit 6 HD 2-channel" For the order of a "Conversion kit 6 HD 2-channel (S26361-F2612-E4)", both channels of the Ultra 320 SCSI controller are connected to one backplane for 3 HDs each.All internal cables and adapters for the basic unit and for components are included. 1x per RX300 S2

U41601-J-Z156-1-76 Options Guide 107

Page 164: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 165: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Related publicationsPRIMERGY manuals are available as PDF files on the ServerBooks CD. The ServerBooks CD is part of the ServerView Suite delivered with each server system.

The current version of the necessary manuals can be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL:http://manuals.fujitsu-siemens.com (choose: intel based servers/PRIMERGY ServerBooks).

[1] Safety

[2] Warranty

[3] PRIMECENTER Rack Technical Manual

[4] DataCenter Rack Technical Manual

[5] 19 inch rack Technical Manual

[6] LocalView User Manual

[7] PRIMERGY ServerView Suite ServerStart

[8] ServerView Server ManagementUser Manual

[9] ServerView ExtensionServerView Extension for HP OpenView NNM

[10] ServerView/Plus for Tivoli

[11] RemoteView User Manual

U41601-J-Z156-1-76 Options Guide 109

Page 166: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Related Publications

[12] RemoteView Service Board S2/S2 LP 1.xMounting and Setting Up User’s Guide

[13] PRIMERGY RX300 S2 Operating Manual

[14] System Board D1889 Technical Manual

[15] BIOS-Setup Reference Manual

[16] Integrated Mirroring User’s Guide

[17] Global Array Manager Client Software User’s Guide

[18] Global Array Manager Server Software User’s Guide

[19] Configurator For partners and distributors only:http://extranet.fujitsu-siemens.com/cafe/products/primergy

110 Options Guide U41601-J-Z156-1-76

Page 167: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Index

Aaccessible drives 3, 37air duct 22

Ccache module 35chipDISK 4, 63Controller 4, 56, 58conversion of SCSI 1-channel version

to 2-channel version 5converting form low profile to standard

slots 93converting from SCSI-1-channel to 2-

channel 85

Ddual operation 27, 32

EESD (electrostatic sensitive device)

13external SCSI interface 5, 67

HHard disk drives 4

IiButton 36information material 2

Llight-emitting diode (LED) 13Lithium battery 11LocalView module 3, 43

Mmain memory 3, 19meaning of the symbols 6multiprocessor operating system 27,

32

Nnotational conventions 6note about the laser 13

Pparallel interface 5, 79processor 27

RRemoteView 4RemoteView Service Board S2 LP 5,

64ROMB 3

Sslot cover 67

Ttarget group 1

U41601-J-Z156-1-76 Options Guide 111

Page 168: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 169: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Comments on PRIMERGY RX300 S2Server System

U41601-J-Z156-1-76

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MunichGermany

Fax: (++49) 700 / 372 00000

email: [email protected]://manuals.fujitsu-siemens.com

Page 170: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 171: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Comments on PRIMERGY RX300 S2Server System

U41601-J-Z156-1-76

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MunichGermany

Fax: (++49) 700 / 372 00000

email: [email protected]://manuals.fujitsu-siemens.com

Page 172: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical
Page 173: PRIMERGY RX300 S2 Server System - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/RX300_S2R/pdf/... · PRIMERGY RX300 S2 Server System ... the Options Guide and the Technical

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009