PRIMERGY

PRIMERGY L200Server System

JacobFujitsu Siemens Computers GmbH München81730 Muniche-mail: Internet:[email protected].: (089) 61001-161Fax: (++49) 700 / 372 00000A26361-K647-Z102-3-7619Sprachen: En

Edition November 2002

Page 2: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Comments… Suggestions… Corrections…The User Documentation Department would like to know your opinion on this manual. Your feedback helps us to optimize our documentation to suit your individual needs.

Fax forms for sending us your comments are included at the back of the manual.

There you will also find the addresses of the relevant User Documentation Department

Copyright and Trademarks

Copyright © 2001 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

This manual was produced bycognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

This manual is printed on paper treated with chlorine-free bleach.

Page 3: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Introduction

Important Notes

Installation

Preparation For Use And Operation

Property And Data Protection

Troubleshooting And Tips

System Components And Expansions

Reference Section And Index

Page 4: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München
Page 5: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.3 Notational Conventions . . . . . . . . . . . . . . . . . . . . . . 51.4 Target Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2 Important Notes . . . . . . . . . . . . . . . . . . . . . . . . . 92.1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.2 CE Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . 132.3 FCC Class A Compliance Statement . . . . . . . . . . . . . . 132.4 Transporting the Server . . . . . . . . . . . . . . . . . . . . . 142.5 Notes on Mounting in the Rack . . . . . . . . . . . . . . . . . 142.6 Environmental Protection . . . . . . . . . . . . . . . . . . . . 15

3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 173.1 Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . 173.2 Unpacking the Server . . . . . . . . . . . . . . . . . . . . . . 173.3 Mounting the Server in the Rack . . . . . . . . . . . . . . . . 183.3.1 Requirements of the Rack . . . . . . . . . . . . . . . . . . . . 183.3.2 Mounting into the PRIMECENTER or into the DataCenter Rack 213.3.3 Mounting in the Classic Rack . . . . . . . . . . . . . . . . . . 233.3.4 Mounting in 3rd-Party Racks . . . . . . . . . . . . . . . . . . . 253.3.5 Installing the Server . . . . . . . . . . . . . . . . . . . . . . . 263.3.6 Routing Cables . . . . . . . . . . . . . . . . . . . . . . . . . 273.4 Connecting Devices to the Rack Model . . . . . . . . . . . . . 283.5 Connecting Server to Line Voltage . . . . . . . . . . . . . . . 293.6 Instructions on Connecting and Disconnecting Cables . . . . . 29

4 Preparation for Use and Operation . . . . . . . . . . . . . . 314.1 Front Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314.2 Operation Panel on the Front Side . . . . . . . . . . . . . . . . 334.2.1 Operation Controls . . . . . . . . . . . . . . . . . . . . . . . . 344.2.2 Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344.2.3 Indicators on the Drives . . . . . . . . . . . . . . . . . . . . . 354.3 Indicators on the Rear Side . . . . . . . . . . . . . . . . . . . 364.3.1 Status LED on the External Connector Panel . . . . . . . . . . 364.4 Switching the Server ON and OFF . . . . . . . . . . . . . . . 37

A26361-K647-Z102-3-7619

Page 6: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Contents

4.5 Configuration with ServerStart . . . . . . . . . . . . . . . . . . 384.5.1 Installation Procedure in ServerStart . . . . . . . . . . . . . . . 394.5.2 Guided Installation of a Single Server . . . . . . . . . . . . . . 404.5.3 Replicated Installation of Several Servers (Windows) . . . . . . 424.6 Cleaning the Server . . . . . . . . . . . . . . . . . . . . . . . . 45

5 Property and Data Protection . . . . . . . . . . . . . . . . . . 475.1 BIOS Setup Security Functions . . . . . . . . . . . . . . . . . . 47

6 Troubleshooting and Tips . . . . . . . . . . . . . . . . . . . . 496.1 Power-On Indicator Remains Dark . . . . . . . . . . . . . . . . 496.2 Server Switches Itself Off . . . . . . . . . . . . . . . . . . . . . 506.3 Screen Remains Blank . . . . . . . . . . . . . . . . . . . . . . 506.4 Flickering Stripes on Monitor Screen . . . . . . . . . . . . . . . 516.5 No Screen Display or Display Drifts . . . . . . . . . . . . . . . . 516.6 No Mouse Pointer Displayed on Screen . . . . . . . . . . . . . 526.7 Cannot Read or Write to Floppy Disk . . . . . . . . . . . . . . . 526.8 Time and/or Date Not Correct . . . . . . . . . . . . . . . . . . 526.9 System Will Not Boot . . . . . . . . . . . . . . . . . . . . . . . 536.10 Drives Are Reported as "Dead" . . . . . . . . . . . . . . . . . . 536.11 Added Drive Reported Defective . . . . . . . . . . . . . . . . . 536.12 Error Messages on the Screen . . . . . . . . . . . . . . . . . . 54

7 System Components and Expansions . . . . . . . . . . . . . 557.1 SCSI Hard Disk Subsystem . . . . . . . . . . . . . . . . . . . . 557.1.1 Components and Indicators of the Hard Disk Module . . . . . . 567.1.2 Installing/Removing a SCSI Hard Disk Module . . . . . . . . . 587.1.3 Replacing a Hard Disk Module During Operation -Hot Swapping 62

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

A26361-K647-Z102-3-7619

Page 7: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

1 IntroductionThe PRIMERGY L200 server is an Intel-based server for small and medium sized networks. The compact design (only 1HE height) makes a perfect fitting in the data center. The server provides an optimised Web- or Application-Hosting with its highest scalability and security features. Data warehouse solutions are also application areas for the PRIMERGY L200.

The PRIMERGY L200 servers offer a high level of failure safety and availability through highly developed hardware and software components. These include hot swappable hard disk slide-in modules, server management ServerView, Prefailure Detection and Analyzing (PDA) and Automatic Server Reconfigu-ration and Restart (ASR&R).

Security functions an the BIOS Setup and on the system board protect the data on the server against manipulation.

This Operating Manual tells you how to put your server into operation, operate in daily use, configurate, installing in the rack, and helps you in the case of a problem.

Further information is provided:

● on the PRIMERGY ServerBooks CD

– operating manual in up to five languages

– technical manual for the system board

– installation instructions for the corresponding rack

– user guide for the ServerView software product

– user guide for the RemoteView software product

– user guide for adapter cards

● in the manual for "Safety, Warranty, and Ergonomics"

● in the manual for the monitor

● in the documentation for the operating system

● in the information files for the operating system

(See also “Related Publications” on page 69).

A26361-K647-Z102-3-7619 1

Page 8: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Features Introduction

1.1 Features

System Board D1307

The features of the system board can be found on the PRIMERGY ServerBooks CD (see “Related Publications” on page 69).

Hard disk subsystem and onboard SCSI controller

The hard disk subsystem consists of three 3.5-inch hard disk modules and the SCSI backplane. Each hard disk module can accommodate a SCSI hard disk drive with an SCA (Single Connector Attachment) interface and a maximum height of 1. The module is connected to the SCSI disk without cables via the SCA interface. This allows hard disk modules to be simply plugged in or pulled out.

The hard disk subsystem is designed for Ultra3 SCSI. The hard disk subsystem can be controlled by a standard controller or by a RAID controller. You will find one SCSI controller onboard. If the server is equipped with a RAID controller with the corresponding RAID configuration, any defective hard disk module can also be replaced during operation (hot swap).

Accessible drives

The PRIMERGY L200 server contains device bays for one 3.5 inch slimline floppy disk drive and one 5.25 inch slimline CD-ROM drive. Both drives are installed as standard.

Onboard LAN and VGA

The system board contains two redundant 10/100 MBit/s (Fast Ethernet) TX LAN controllers and an ATI Rage XL graphics controller with 8 MB memory onboard.

Power supply

The PRIMERGY L200 server is equipped with a permanently installed power supply unit.

2

A26361-K647-Z102-3-7619
Page 9: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

A26361-K647-Z102-3-7619 3

Introduction Features

Extension slots

The PRIMERGY L200 server is equipped with two PCI slots:

– PCI slot 64 bit/66 MHz for a long or a short PCI board

– PCI slot optional 64 bit/66 MHz for a short PCI board or 32 bit/33 MHz for the RSB board.

ChipDISK onboard

An onboard compact flash disk adapter for RemoteView is designed in the system board of the L200 server.

High level of availability and failure protection

When accessing stored data, 1-bit-errors in the main memory are automatically recognized and corrected (ECC = Error Checking and Correction).

ASR&R tunes out defective system components during an automatic system reboot.

The Prefailure Detection and Analysing Technology reports the threat of system errors or problems to the system administrator so that preventative measures can be taken.

The optional disk array controller increases system availability and supports the RAID levels 0,1 and 5. The hot swappable hard disks provide additional protection.

Server management

Server management is implemented with the aid of the supplied ServerView software and PDA (Prefailure Detection and Analyzing) technology from Fujitsu Siemens. PDA analyzes and monitors all components that are vital for the system's reliability.

ServerView enables the management of all PRIMERGY servers in the network via a central console. Here ServerView supports the following functions:

● Remote power-on (Wake On LAN)

● Temperature monitoring of the CPU and the surrounding area.

● Timer-controlled switch-on (Timer)

● Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event of failure of memory modules or processors.

Page 10: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Options Introduction

● Power monitoring

● End-of-Life monitoring of the fans with timely notification before a failure

● Watchdog timer for operating system monitoring and application monitoring

● Detailed status error reports for bus systems, processors and main memory

● Storage of error messages in the non-volatile SRAM memory

Further information on the ServerView server management is provided in the associated documentation (see “Related Publications” on page 69).

ServerStart

You can configure the PRIMERGY server quickly and purposefully with the ServerStart software provided. User-guided menus are available for installing the server operating systems.

Service and Support

PRIMERGY servers are service-friendly and modular, thus enabling quick and simple maintenance. The flash EPROM program supplied with the FSC utilities supports fast BIOS update BIOS update. With the optional Remote Test and Diagnosis System RemoteView, long-distance maintenance and service (remote) can also be performed on the servers of the PRIMERGY series.

1.2 Options

RemoteView Service Board

The RemoteView Service Board (RSB) is included in the integrated Server Management Concept from Fujitsu Siemens, RemoteView and ServerView. It consists of software and hardware components which allow remote monitoring and maintenance as well as a rapid return to operational integrity in the event of an error. Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and to an excellent return on investment for the remote management solution.

The RemoteView Service Board (RSB) is a PCI board with a completely independent system. It has its own operating system with web server and SNMP agent and can optionally be powered by an external power supply. The RSB is mounted in a standard PCI slot and connected with a power cable and

4

A26361-K647-Z102-3-7619
Page 11: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

A26361-K647-Z102-3-7619 5

Introduction Notational Conventions

data cable to the system board. The RSB facilitates a remote diagnosis for system analysis, remote system configuration, and remote restart should the operating system or hardware fail. It is supplied with its own LAN connection as well as its own COM port. In this way, all functions are made available either via LAN or via modem.

1.3 Notational Conventions

The meanings of the symbols and fonts used in this manual are as follows:

1.4 Target Group

This manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. The operating manual contains all the information required for installing and operating your PRIMERGY L200.

V CAUTION! Pay particular attention to texts marked with this symbol. Failure to observe this warning endangers your life, destroys the system, or may lead to loss of data.

Ê Texts which follow this symbol describe activities that must be performed in the order shown.

Text in italics indicate commands or menu item.

"Quotation marks" indicate names of chapters and terms that are being emphasized

I This symbol is followed by supplementary information, remarks and tips.

Page 12: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Technical Data Introduction

1.5 Technical Data

Electrical data

National and international standards

Rated voltage range 100-125 V / 200-240 V

Frequency 50 Hz - 60 Hz

Rated current in basic configuration 100-125 V / 1.35 A200-240 V / 0.7 A

Max. rated current 100-125 V / 2.0 A200-240 V / 1.0 A

Effective power 178 W

Apparent power 205 VA

Heat emission 641 kJ/h

Building fuse 16 A

Protection class I

Product safety IEC 60950 / EN 60950 / UL 1950, CSA 22.2 No. 950

Electromagnetic compatibility FCC class AVCCI class AAS / NZS 3548 class A

Interference emission EN 55022

Harmonic current EN 6100-3-2 JEIDA

flicker EN 61000-3-3

Interference immunity EN 55024

CE certificationto EU directives:

73/23/EEC (llow voltage directive)89/336/EEC (Electromagnetic compatibility)

6 A26361-K647-Z102-3-7619

Page 13: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Introduction Technical Data

Dimensions

Weight

approx. 13-15 kg (depending on the configuration)

Ventilation intervals

To ensure sufficient ventilation of the system, a minimum clearance of 200 mm must be provided at the front and the rear of the server.

Environmental conditions

Condensation in operating must be avoided.

Noise level

Rack Model

Width 448 mm

Depth 700 mm

Height 43.2 mm (1 height units)

Environment class 3K2Environment class 2K2

DIN IEC 721 part 3-3DIN IEC 721 part 3-2

Temperature:

– Operating (3K2)– Transport (2K2)

15 °C .... 35 °C-25 °C .... 60 °C

Humidity 10 ... 85%

Sound power level LWAd (ISO 9296): ≤ 6.5 B

Sound pressure level at bystander position LpAm (ISO 9296)

≤ 50 dB(A)

A26361-K647-Z102-3-7619 7

Page 14: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München
Page 15: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

2 Important NotesIn this chapter you will find information regarding safety which it is essential to take note of when working with your server.

2.1 Safety

I The following safety notes are also provided in the manual “Safety, Warranty and Ergonomics“, which contains additional information about warranty and ergonomics.

This device complies with the relevant safety regulations for data processing equipment, including electronic office machines for use in an office environment.

If you have any questions, contact your sales office or our customer service.

V CAUTION!

● The actions described should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by qualified staff. Any failure to observe the guide-lines in this manual could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.

Before operating the device

V CAUTION!

● During installation and before operating the device, observe any instructions on environmental conditions (see section “Technical Data” on page 6).

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

A26361-K647-Z102-3-7619 9

Page 16: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Safety Important Notes

Installation and operation

V CAUTION!

● The server automatically sets itself to a voltage in the 100 V to 240 V range. Make sure that your local voltage is within this range.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket.

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The power switch does not disconnect the device from the line voltage. To disconnect the line voltage completely, remove the power plug from the grounded insulated socket.

● Connect the device and the attached peripherals to the same circuit (data loss).

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

● Data cables to peripheral devices must be adequately shielded.

● Please ensure that no objects (e. g., necklaces, paperclips etc.) or liquids can get into the interior of the device (electrical shock, short circuit).

● In emergencies (e.g. damaged casing, elements or cables, penetration of liquids or foreign matter), switch off the device immedi-ately, remove the power connector and contact your sales office or customer service.

10 A26361-K647-Z102-3-7619

Page 17: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Important Notes Safety

Proper operation of the system, warranty

V CAUTION!

● Proper operation of the system (in accordance with IEC950/EN60950) is only ensured if the casing is completely assembled and the rear covers have been put in place (electric shock, cooling, fire protection, interference suppression).

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

Batteries

V CAUTION!

● Incorrect replacement of device’s battery may lead to a risk of explosion. The battery may be replaced only with an identical battery or with a type recommended by the manufacturer (see Technical Manual of the system board or chapter “Related Publications” on page 69).

● Do not throw batteries into the trash can. The battery must be disposed of in accordance with local regulations concerning special waste.

Note on the laser

The CD-ROM drive contains an LED (light-emitting diode) classified according to IEC 825-1:1993:LASER CLASS 1.

A26361-K647-Z102-3-7619 11

Page 18: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Safety Important Notes

Modules with electrostatic-sensitive components:

Systems and components which might be damaged by electrostatic discharge (ESD) can be marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● You must always discharge yourself (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charges.

● Pull out the power plug before inserting or pulling out components containing ESDs.

● Always hold components with ESDs by their edges.

● Never touch pins or conductors on boards fitted with ESDs.

Other important points:

● When cleaning the server, observe the relevant notes in the section “Cleaning the Server” on page 45.

● Keep this Operating Manual safety and all additional documentation (e.g. PRIMERGY ServerBooks CD) in a safe place together with the device. If you pass on the device to third parties, you should also pass on the whole documentation.

12 A26361-K647-Z102-3-7619

Page 19: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Important Notes CE Certificate

2.2 CE Certificate

V WARNING!

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

2.3 FCC Class A Compliance Statement

If there is an FCC statement on the device, then:

The following statement applies to the products covered in this manual, unless otherwise specified herein. The statement for other products will appear in the accompanying documentation.

NOTE:

This equipment has been tested and found to comply with the limits for a "Class A" digital device, pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference-Causing Equipment Regulations. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in strict accor-dance with the instructions, may cause harmful interference to radio communi-cations. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

● Reorient or relocate the receiving antenna.

● Increase the separation between equipment and the receiver.

● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

The shipped version of this device complies with the requirements of the EEC directives 89/336/EEC "Electromagnetic compatibility" and 73/23/EEC "Low voltage directive". The device therefore qualifies for the CE certificate (CE=Communauté Européenne).

A26361-K647-Z102-3-7619 13

Page 20: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Transporting the Server Important Notes

● Consult the dealer or an experienced radio/TV technician for help.

Fujitsu Siemens Computers is not responsible for any radio or television inter-ference caused by unauthorized modifications of this equipment or the substi-tution or attachment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

The use of shielded I/O cables is required when connecting this equipment to any and all optional peripheral or host devices. Failure to do so may violate FCC rules.

2.4 Transporting the Server

V CAUTION!

Transport the server only in its original packaging or in a packaging which protects it from knocks and jolts, to the new site. Do not unpack the server until all transport maneuvers are completed.

2.5 Notes on Mounting in the Rack

● When connecting and disconnecting cables, observe the notes in the documentation for your PRIMERGY system and the comments in the "Important notes" chapter in the corresponding rack operating manual supplied with the rack (see also “Related Publications” on page 69).

● Ensure that the anti-tilt bracket is correctly mounted when you set up the rack.

● For safety reasons, no more than one unit may be withdrawn from the rack at any one time during installation and maintenance work.

● If more than one unit is withdrawn from the rack at any one time, there is a danger that the rack will tilt forward.

● The power supply to the rack must be installed by an authorized specialist (electrician).

14 A26361-K647-Z102-3-7619

Page 21: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Important Notes Environmental Protection

2.6 Environmental Protection

Environmentally friendly product design and development

This product has been designed in accordance with the FSC standard “environ-mentally friendly product design and development”.

This means that the designers have taken into account decisive criteria such as durability, selection of materials and coding, emissions, packaging, the ease with which the product can be dismantled and the extent to which it can be recycled.

This saves resources and thus reduces the harm done to the environment.

Note on saving energy

Devices that do not have to be switched on permanently, should be switched off until they are needed. During long breaks and after completion of work, the devices should be switched off.

Notes on packaging

We recommend that you do not throw away the original packaging in case you need it later for transporting your system unit. If possible, the system unit and the devices should only be transported in their original packaging.

Note on dealing with consumables

Please dispose of printer consumables and batteries in accordance with local government regulations.

Do not throw batteries or accus into the trash can. It must be disposed of in accordance with local regulations concerning special waste.

Note on labeling plastic housing parts

Please avoid sticking your own labels on plastic housing parts or wherever possible, since this makes it difficult to recycle them.

A26361-K647-Z102-3-7619 15

Page 22: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Environmental Protection Important Notes

Take-back, recycling and disposal

For details on take-back and reuse of devices and consumables within Europe, contact your FSC branch office/subsidiary or our recycling center in Paderborn:

Fujitsu Siemens Computers GmbHRecycling CenterD-33106 PaderbornGermanyTel.: +49 5251 818010Fax: +49 5251 818015

Further information on environmental protection

The Fujitsu Siemens Computers GmbH representative for environmental protection will be pleased to answer any further questions you may have concerning environmental protection.

Fujitsu Siemens Computers GmbHEnvironmental ProtectionWerner-von-Siemens-Straße 6D-86159 AugsburgGermanyTel.: +49 821 804-2386Fax +49 821 804-2706

16 A26361-K647-Z102-3-7619

Page 23: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

3 InstallationV CAUTION!

Please observe the safety information in chapter “Important Notes” on page 9.

Do not expose the server to extreme environmental conditions (see section “Technical Data” on page 6). Protect it from dust, humidity, and heat.

I There must be a clearance of at least 200 mm in front of and behind the server to ensure adequate ventilation. Do not cover the ventilation areas of the monitor and the server.

3.1 Installation Steps

Ê Unpack the server (see next section “Unpacking the Server”).

Ê Mount the sliding rails and insert the server into the rack (see order lists for location diagram prepared with the Rack architect).

Ê The server will be attached directly (see section “Instructions on Connecting and Disconnecting Cables” on page 29).

Ê Connect the server to the power supply (see section “Connecting Server to Line Voltage” on page 29).

3.2 Unpacking the Server

V CAUTION!

Please take note of the safety information in the chapter “Important Notes” on page 9.

Do not unpack the server until it is at its installation location.

It is recommended to not throw away the original packaging material! It may be required for transportation at some later date.

Ê Unpack all individual parts.

Ê Check the delivery for damage during transport.

Ê Check whether the delivery agrees with the details in the delivery note.

A26361-K647-Z102-3-7619 17

Page 24: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Mounting the Server in the Rack Installation

The identification rating plate is located on the bottom of the server.

Should you discover that the delivery does not correspond to the delivery note, notify your supplier immediately.

3.3 Mounting the Server in the Rack

V CAUTION!

Please observe the safety information in chapter “Important Notes” on page 9.

The rack may tip over if more than one heavy unit is removed.

3.3.1 Requirements of the Rack

The rack systems of the Fujitsu Siemens Computers GmbH (19-Inch (Classic) Rack; DataCenter Rack and PRIMECENTER Rack) support fully the installation of the PRIMERGY server systems. The installation into the present rack systems from different manufacturers (3rd-Party Rack) can also be supported.

To accommodate the ventilation concept and ensure proper ventilation of the components in the rack, any unused areas must be closed using dummy covers.

The power is supplied via the socket strips available in the rack.

The main features of the rack systems of the Fujitsu Siemens Computers GmbH are:

PRIMECENTER Rack

– Frontally bolted telescopic rails or sliding rails.

The rails are provided with a linear alignment to ensure an adjustment to different rack depths.

– Extended cable management within the lateral rack area.

DataCenter Rack

– Frontally bolted telescopic rails or sliding rails (except within the rear left area where a support bracket is used).

– Extended cable management within the lateral rack area.

18 A26361-K647-Z102-3-7619

Page 25: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Installation Mounting the Server in the Rack

19-Inch (Classic) Rack

– Directly laterally bolted telescopic rails or sliding rails.

– Cable management by using an articulated cable carrier.

The mounting of the corresponding rails in the different racks is described in the next sections.

The mounting of the cable management is described in detail in the Technical Manual to the respective rack.

To rack systems of different foreign manufacturers the following applies:

3rd-Party Rack

Certain boundary conditions are to be fulfilled:

– Installation dimensions (see the dimensions shown in figure 2 on page 20).

1 rack front side

2 rack rear sideA rack depth (comparison PRIMECENTER Rack 940/1000 mm)B rack width (comparison PRIMECENTER Rack 700 mm)C clearance of the 19-inch installation levelC1 front 19-inch installation levelC2 rear 19-inch installation level

D area for cable routing (cable area depth) and ventilationE area for front panel and ventilationF right and left area for support systemsP PRIMERGY installation deptha1 front left support uprighta2 front right support upright

b1 rear left support uprightb2 rear right support upright

A26361-K647-Z102-3-7619 19

Page 26: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Mounting the Server in the Rack Installation

Figure 2: Mechanical conditions

20 A26361-K647-Z102-3-7619

Page 27: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Installation Mounting the Server in the Rack

– The operability of the safety mechanisms at the server e.g. stoppers or holding back systems must be guaranteed.

– The form of the rack support uprights must ensure the frontal assembly of the rails.

– Frontally bolted telescopic rails or sliding rails.The rails are provided with a linear alignment to ensure an adjustment to different rack depths.

– no support of the cable management (delivered with the mounting kit).

– Climatic conditions.For the air discharge ventilation of the installed server, ensure that in the rack from front to rear the air flow is accessible.In principle the ventilation concept plans that the necessary cooling is reached by the horizontal self-ventilation of the installed devices (air flow from the front to the rear).

– Power supply.For the installation in 3rd-Party Racks it is to be made certain that appro-priate socket strips are present.

3.3.2 Mounting into the PRIMECENTER or into the DataCenter Rack

For mounting the server in the PRIMECENTER Rack the following parts are necessary:

– support bracket– two sliding rails – eight mounting springs (figure 3 on page 22)

For mounting the left sliding rail in the PRIMECENTER or DataCenter Rack, the delivered support bracket must first be mounted on the rear left support upright. The bracket must be mounted level with the lower edge of the device.

Ê Refer to the assembly instructions in the technical manual for the corre-sponding rack (see also “Related Publications” on page 69).

I For better orientation the height units are marked on the support uprights (only PRIMECENTER Rack).

Ê Mount the support bracket at the appropriate height on the left rear support upright as described in the technical manual of the corresponding rack.

A26361-K647-Z102-3-7619 21

Page 28: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Mounting the Server in the Rack Installation

To fasten the sliding rails, no flange nuts are necessary since the rails are equipped with threaded holes. For adjustment in each case two mounting springs must be pre-mounted at the support uprights and the support bracket:

Figure 3: Mounting the springs in the support bracket

Ê Place the mounting springs (1) in the holes of the support uprights and/or of the support bracket as illustrated above.

Figure 4: Mounting the sliding rail in the PRIMECENTER/DataCenter Rack

22 A26361-K647-Z102-3-7619

Page 29: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Installation Mounting the Server in the Rack

Ê Secure the end of the sliding rails with two Phillips screws each (1 and 2) in the rack at the support uprights both front and rear as illustrated above.

Note: For the other side one end of the rail must be secured at the support bracket.

Note: Two mounting springs each are used in the appropriate openings of the support uprights and/or the support bracket (see figure 3 on page 22).

Ê Adjust if necessary the length of the sliding rails by using the oblong holes of the rails.

Ê Mount the server (see section “Installing the Server” on page 26).

Ê Route the cables with the inserted server as described in the technical manual of the corresponding rack.

3.3.3 Mounting in the Classic Rack

For mounting the server in the Classic (19-inch 42/23 HU) Rack the following parts are necessary:

– two sliding rails – eight mounting springs (figure 3 on page 22)

To mount the server in the Classic (19-inch 42/23 HU) Rack, spring nuts must first be inserted in the support uprights.

Ê Refer to the assembly instructions in the technical manual for the Classic (19-inch 42/23 HU) Rack (see “Related Publications” on page 69).

Ê Mark the position of the attachment points for the sliding rails and for the server (front panel) on the support uprights (one height unit). Refer to the layout diagram on the order lists created with the System Architect program for help.

Ê Place the spring nuts to fasten the sliding rails in the groove of the support uprights at the marked attachment points.

Ê If necessary, adjust the position of the nuts in the groove until they lock into the correct position.

A26361-K647-Z102-3-7619 23

Page 30: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Mounting the Server in the Rack Installation

Figure 5: Mounting the sliding rails in the 42/23 HU rack

Ê Secure the two sliding rails with two screws each in the rack at the right and left support uprights (2).

Please note that the guide nubs (1) of the rails must fit into the holes in the support uprights.

Ê Mount the server (see section “Installing the Server” on page 26).

24 A26361-K647-Z102-3-7619

Page 31: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Installation Mounting the Server in the Rack

3.3.4 Mounting in 3rd-Party Racks

For mounting the server in a 3rd-Party Rack the following parts are necessary:

– support bracket (if necessary)– two sliding rails – possibly eight mounting springs (figure 3 on page 22)

Ê Take the original manual of the rack manufacturer regarding the mechanical installation and/or the climatic conditions to assistance.

V CAUTION!

With the installation in 3rd-Party Rack ensure that in the rack from front to rear the air flow is accessible.

Ê Mount the necessary manufacturer original parts (like support bracket).

I Sometimes a series of parts of the delivered mounting kit cannot be used because original parts of the 3rd-Party Rack are to be used.

Ê Mount the sliding rails in the 3rd-Party Rack as described in section “Mounting into the PRIMECENTER or into the DataCenter Rack” on page 21.

Ê Mount the server (see section “Installing the Server” on page 26).

Ê Route the cables as described in the original manual of the Rack.

A26361-K647-Z102-3-7619 25

Page 32: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Mounting the Server in the Rack Installation

3.3.5 Installing the Server

Ê Insert spring nuts on the support uprights at the marked attachment points.

Figure 6: Installing server in the rack

Ê Slide the server into the rack.

26 A26361-K647-Z102-3-7619

Page 33: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Installation Mounting the Server in the Rack

Figure 7: Fasten the server

Ê Fasten the server to the rack using the two knurled screws.

To remove the server, follow the same procedure in reverse order.

3.3.6 Routing Cables

The cables are routed using the cable channels on the support uprights.

A26361-K647-Z102-3-7619 27

Page 34: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Connecting Devices to the Rack Model Installation

3.4 Connecting Devices to the Rack Model

The ports for external devices and the slots for expansion cards are on the rear of the server. Which ports are available on your server depends on the boards installed.

The standard ports are indicated by symbols and by color coding for the connectors.

Figure 8: PRIMERGY L200 rear side with the external connector panel

I The serial port COM2 is optional, but is not available as a standard connection on the rear of the server.

I Some of the devices that you connect require special drivers (see the documentation for the connected device).

Ê Connect the data cables to the server and peripherals.

1 = Error detection and Status LED 7 = LAN port 0

2 = Keyboard port (purple) 8 = LAN port 1

3 = Mouse port (green) 9 = Extension slot (full length)

4 = VGA port (blue) 10 = Extension slot (short length)

5 = Serial port COM1 (turquoise) 11 = Line cable

6 = USB port 1+2 (black)

28 A26361-K647-Z102-3-7619

Page 35: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Installation Connecting Server to Line Voltage

3.5 Connecting Server to Line Voltage

The server is equipped with a permanently installed power supply unit.

Ê Connect the power cord of the server into the connector strip of the rack (see “Related Publications” on page 69).

3.6 Instructions on Connecting and Disconnecting Cables

V CAUTION!

Be sure to read the documentation for the peripheral devices before connecting them.

Do not connect or disconnect cables during a thunderstorm.

When removing a cable, always hold it by the plug. Never unplug a cable by pulling the cable itself.

Connect and disconnect the cables in the order described below.

Connecting cables

Ê Turn off all power and equipment switches.

Ê Pull all power plugs out of the grounded power sockets.

Ê Plug all cables into the server and peripherals.

Ê Plug all data communication cables into the utility sockets.

Ê Plug all power cables into the grounded power sockets.

Disconnecting cables

Ê Turn off all power and equipment switches.

Ê Pull all power plugs out of the grounded power sockets.

Ê Unplug all data communication cables from the utility sockets.

Ê Disconnect the relevant cables from the server and all the peripherals.

A26361-K647-Z102-3-7619 29

Page 36: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Instructions on Connecting and Disconnecting Cables Installation

Disconnecting cables with the LAN unlocking tool

The two PCI slot cover plates on the rear of the server are located in one centi-meter recess in the casing interior. To disconnect LAN cables more easily (e. g. from the Remote Service Board), a LAN unlocking tool is included in the delivery pack (see figure 9).

Figure 9: Disconnecting cables with the LAN unlocking tool

Ê To disconnect a cable, set the tool onto the locking tab of the LAN connector and press it down (1) until the locking mechanism disengages.

Ê Remove the cable (2).

I After usage the tool can be attached to the power cable.

Ê Attach the unlocking tool to the power cable (3).

30 A26361-K647-Z102-3-7619

Page 37: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

4 Preparation for Use and Operation

V CAUTION!

Please observe the safety information in chapter “Important Notes” on page 9.

4.1 Front Side

The operation panel of the PRIMERGY L200 server allows easy access to the drives, front panel, USB port, and LCD display (optional).

Figure 10: PRIMERGY L200 front side

1 = Slimline CD ROM drive

2 = USB Port

3 = Operation panel

4, 5, 6 = 1 inch SCSI hard disk drive

7 = Slimline floppy disk drive

A26361-K647-Z102-3-7619 31

Page 38: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Front Side Preparation for Use and Operation

Slimline floppy disk drive

The following formats are supported by the system: 720 Kbyte, 1.2 MB, 1.44 MB.

Slimline CD ROM drive

V CAUTION!

Risk of damage! Secure the CD-ROM carrier while inserting the CD.

Figure 11: Manually removing the CD

I In the event of power failure or damage to the drive it may be necessary to manually remove the CD.

Ê Insert a pointed object (ex: bent paper clip) into the hole of the CD-ROM for manual injection (1).

32 A26361-K647-Z102-3-7619

Page 39: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Operation Panel on the Front Side

4.2 Operation Panel on the Front Side

Figure 12: Operation panel on the front side

1 = Power-on indicator 4 = Reset button

2 = SCSI indicator 5 = ON/OFF button

3 = Message LED 6 = NMI button

A26361-K647-Z102-3-7619 33

Page 40: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Operation Panel on the Front Side Preparation for Use and Operation

4.2.1 Operation Controls

4.2.2 Indicators

ON/OFF buttonWhen pressing the ON/OFF button you can either turn the system off or on.If the device does not respond, press and hold the button for at least 4 seconds.

I The Power button does not disconnect the server from the line voltage. To completely disconnect the line voltage, unplug the power cable.

Reset buttonPressing the Reset button restarts the System via BIOS.The Reset button can only be activated with a pointed object (ex: bent paper clip).

NMI button (for Japan)Without the required software, this button is the same as the Reset button.

Power-on indicator

lights orangewhen the server is switched off but line voltage is present (standby mode).

lights green when the server is switched on.

SCSI indicator

lights green when drives in the hard disk modules are being accessed.

34 A26361-K647-Z102-3-7619

Page 41: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Operation Panel on the Front Side

4.2.3 Indicators on the Drives

CD-ROM drive indicator

lights up when the CD-ROM drive is being accessed.

Floppy disk drive indicator

lights up when the floppy disk drive is being accessed.

Hard disk drive indicator

Message LED

is darkThis system is operational. The status of the server can be deter-mined by the power-on indicator.

flashes orangeAn error has occurred in the system.

If ServerView agents have been installed, the type of error may be determined by using ServerView. Once the type of error has been identified, the flashing LED is reset.

If no ServerView agents are installed, [F1] should be pressed in BIOS Setup so that the error type can be identified in the ErrorLog. The flashing LED is reset after exiting BIOS Setup.

lights orangeThis system was explicitly selected by the administrator so that the service technican will be able to identify the selected system.The LED is reset by a command from ServerView. If the system is switched off, for a long time and still remains connected to the line voltage the LED will remain in the last state it was set to.

Hard disk drive active

lights greenwhen the drive in this module is being accessed.

A26361-K647-Z102-3-7619 35

Page 42: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Indicators on the Rear Side Preparation for Use and Operation

4.3 Indicators on the Rear Side

4.3.1 Status LED on the External Connector Panel

lights orange

1. The server is switched off, but line voltage is present (standby mode)or

2. The system was explicitly selected by the administrator so that the service technican will be able to identify the selected system.The LED is reset by a command from ServerView. If the system is switched off, so long as it remains connected to the line voltage the LED will remain in the last state it was set to.

Only by checking the message LED can you determine which of these two is the case.

flashes orange

An error has occurred in the system.

If ServerView agents have been installed, the type of error may be determined by using ServerView. Once the type of error has been identified, the flashing LED is reset.

If no ServerView agents are installed, [F1] should be pressed in BIOS Setup so that the error type can be identified in the ErrorLog. The flashing LED is reset after exiting BIOS Setup.

Drive error (only in conjunction with a RAID controller)

lights orangeif the drive is defective and needs to be replaced, or if the module has been incorrectly inserted.

flashes orangewhen a rebuild is being carried out by a RAID controller after a drive has been exchanged.

36 A26361-K647-Z102-3-7619

Page 43: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Switching the Server ON and OFF

4.4 Switching the Server ON and OFF

V CAUTION!

If after switching on the server there is nothing but flickering stripes on the screen, switch the server off immediately (see chapter “Important Notes” on page 9).

The ON/OFF switch does not disconnect the server from the line voltage. To disconnect the line voltage completely, remove the power plug from the socket strip.

Switching on

Ê Press the ON/OFF button on the front side of the device.

First system installation

Insert the ServerStart CD and any available floppy configuration disk, and restart the device. Follow the instruction in section “Configuration with Server-Start” on page 38.

The server switches on, performs a system test and starts the operating system.

System already installed

The server is switched on, performs a system test and boots the operating system.

I Please note that the memory size displayed during the system test varies according to the PCI slot equipment (if equipped with 4x1GByte).

Switching off

Ê Shut down the operating system in an orderly manner.

Ê Press the ON/OFF switch.

The server is switched off.

A26361-K647-Z102-3-7619 37

Page 44: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Configuration with ServerStart Preparation for Use and Operation

Other ON/OFF possibilities

In addition to the power switch, the server can be switched on in the following ways:

● Specified switch-on time/switch-off timeThe server is switched on or off at a time specified in the ServerView program

● Manually with ServerView FrontendThis function can be configured.

● Ring indicatorThe server is switched on via an external modem.

● Wake On LAN (WOL)The server is switched on by a command via the LAN (Magic Package).

● After power failureThe server is switched on after a power failure (rebooted).

● RemoteThe server can be switched on or reset via LAN/Modem through the RemoteView Service Board.

4.5 Configuration with ServerStart

ServerStart is a powerful tool for setting up your new PRIMERGY server. ServerStart lets you quickly and smoothly configure and install hardware, the operating system, and additional components.

The ServerStart advantage

– Automatically configure your server hardware and disk arrays

– Receive installation help for all leading server operating systems

– Create configuration files for the unattended installation of several PRIMERGY servers with identical hardware configurations

– Install drivers and additional software

I Which software can be installed depends on the hardware configuration of your server. This configuration is automatically detected.

38 A26361-K647-Z102-3-7619

Page 45: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Configuration with ServerStart

Using ServerStart

The ServerStart user interface is divided into two areas. All the menus for the application can be quickly found in the Tree View area on the left. In the User Frame area on the right you can navigate the underlined objects just as you would with an internet browser.

Figure 13: Start-up stream of ServerStart

4.5.1 Installation Procedure in ServerStart

With the help of ServerStart you can carry out the first installation of your server and perform later adjustments.

I Information about the installation can be found in the accompanying booklet for the ServerStart CD-ROM.

Preparation

To install your PRIMERGY server and operating system, you need to boot the computer from the ServerStart CD. In some circumstances you will need to adjust several settings to do this:

A26361-K647-Z102-3-7619 39

Page 46: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Configuration with ServerStart Preparation for Use and Operation

For CD-ROM drives on a IDE bus:

Ê Ensure that the corresponding IDE channel is activated in the BIOS of the system board and that the CD-ROM drive is the first boot device in the boot sequence.

Selecting the desired installation mode

To set up a single server:

It is recommended to configure ServerStart in Guided Mode on the target system. Compared to the Expert Mode, this offers increased security by the recognition and configuration of the hardware. Continue with section “Guided Installation of a Single Server” on page 40.

I If you decide to install in Expert Mode, you will need to know the hard disk capacity and how to remove cards and configure hard disks.

To set up several servers with identical hardware configurations:

In this case, create a target configuration file on a floppy disk either in the Prepa-ration Mode or using the example in the Guided Mode. Continue with section “Replicated Installation of Several Servers (Windows)” on page 42.

I Only one boot system can be selected in the Preparation Mode and in the Guided Mode, and only one RAID array can be set as a boot device. If the capacity of the boot drive cannot be determined, select the “Automatic” option for an optimal partitioning.

4.5.2 Guided Installation of a Single Server

Installation in Guided Mode

In Guided Mode, installation assistants configure your server hardware and disk arrays and then install the operating system and integrated applications. For the new installation, standard settings are loaded from a Default Configuration File. This configuration file can be found on the ServerStart CD and may be edited by the administrator.

40 A26361-K647-Z102-3-7619

Page 47: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Configuration with ServerStart

Proceed as follows:

Ê Switch on the server and place the ServerStart CD in the drive.

Ê Switch off the server and then switch it on again. ServerStart will now be started from the CD-ROM on the target system.

Ê After the boot process the ServerStart user interface appears. Select the installation mode and follow the installation process in the User Frame.

Ê A hardware analysis of the target system is performed and configuration files will be gathered for the installation. Configuration data is gathered for a hardware analysis of the target system.

Ê After the configuration definition has been completed, the installation phase is initiated without any additional restart. Data carriers with the operating system, Service packs, and additional applications are then required to start the installation.

The rest of the installation process including all necessary restarts executes without any input from the user.

I Exception: Necessary specifications that were not made in the configuration phase will be requested during the installation.

Figure 14: Installation in Guided Mode

A26361-K647-Z102-3-7619 41

Page 48: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Configuration with ServerStart Preparation for Use and Operation

I During the installation of Windows NT/2000 and NetWare 5, ServerStart also automatically integrates drivers for system components that are not contained in the operating system. During the installation of other operating systems, ServerStart notifies the user of the missing drivers. If necessary the user can now make a driver installation floppy.

Alternative installation in Expert Mode

In contrast to the Disk and RAID Wizards in the Guided Mode, the Expert Mode lets you directly configure the hardware using the tools specifically from the manufacturer.

– Windows NT Disk Administrator, Global Flash ServicePartition Manager, DuplexData Partition Manager

– Mylex GAM (Global Access Manager), Storage Manager

In connection with the configuration in the Expert Mode, the operating system installation can be performed analogously to the Guided Mode.

I To update BIOS, firmware, and drivers with Global Flash, you will need a service partition. You can set this up conveniently using the Disk Wizard from ServerStart.

4.5.3 Replicated Installation of Several Servers (Windows)

Step 1: Making a boot disk in the Preparation Mode

In this operating mode with the help of the installation assistants, you can create adapted configuration files for the unattended installation of your PRIMERGY server.

I You can also set up installation floppy disks with all the detected config-uration definitions after the configuration of the target system in Guided Mode and in Expert Mode.

42 A26361-K647-Z102-3-7619

Page 49: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Configuration with ServerStart

Proceed as follows:

The Preparation Mode starts if ServerStart was installed as an application on an arbitrary Windows PC. Because this computer is not necessarily the target system, no automatic hardware analysis can take place. You will need to manually fill in the necessary information (LAN topology, computer name, IP address).

Ê Fill in the required information in the corresponding menus.

V CAUTION!

It is important to correctly specify the boot drive:

– Which SCSI device is the boot disk for the SCSI controller (SCSI ID)?

– How many disks are available for a RAID array and which RAID level (0/1/5) should be used?

I Other devices such as graphics cards or network hardware are automat-ically detected and installed on the target system.

Ê After the configuration has been completed, save the gathered information in an arbitrary file with the *.ini extension either on the hard disk or on a floppy disk. This file can be reopened at an time and modified from within configuration user interface.

I In this way you can store several configuration records for various target systems.

Ê In order to install a corresponding target system based on the gathered configuration data, you need to create a boot disk and copy the configuration file to this disk under the filename SerStartBatch.ini.

A26361-K647-Z102-3-7619 43

Page 50: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Configuration with ServerStart Preparation for Use and Operation

Step 2: Configuration of the target system in Replication Mode

Proceed as follows:

I In the BIOS for the system board and SCSI adapter, define the boot sequence such that the CD-ROM drive precedes the floppy disk drive (see “Related Publications” on page 69).

Ê With the configuration disk in the drive, boot the target system from the ServerStart CD. ServerStart starts in Replication Mode and the installation runs automatically based on the configuration file.

Device drivers needed to operate the detected hardware components will be reported and pre installed on the selected operating system.

V CAUTION!

To successfully install in Replication Mode, the configuration data must agree with the hardware configuration on the target system.

I Intervention in the installation process is only necessary to change data carriers (operating system, service packs, applications) and in the event of an incorrect or incomplete hardware recognition.

The installation is complete.

44 A26361-K647-Z102-3-7619

Page 51: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Preparation for Use and Operation Cleaning the Server

4.6 Cleaning the Server

V CAUTION!

Switch the server off, and pull the power plug out of the grounded-contact power socket.

Do not clean any interior parts yourself; leave this job to a service technician.

Do not use any cleaning agents that contain abrasives or may corrode plastic.

Ensure that no liquid enters the system. Ensure that the ventilation areas of the server and the monitor are free.

Use a cloth for disinfection to clean the keyboard and the mouse.

Wipe the server and monitor casing with a dry cloth. If particularly dirty, use a cloth that has been moistened in a mild domestic detergent and then carefully wringing it out.

A26361-K647-Z102-3-7619 45

Page 52: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München
Page 53: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

5 Property and Data ProtectionThe rack model is protected against unauthorized access with the lockable rack door.

To protect your system and your data internally from unauthorized access, you can use the BIOS Setup security functions.

5.1 BIOS Setup Security Functions

The Security menu in BIOS Setup offers various options for protecting your data from unauthorized access. By combining these options, you can achieve optimum protection for your system.

I You will find a detailed description of the Security menus and how to assign passwords in the manual for the BIOS Setup and on the PRIMERGY ServerBooks CD (see “Related Publications” on page 69).

Prevent unauthorized BIOS Setup calls

You can activate this protection by setting a setup password in the Security menu. In addition, you can suppress the Press F2 for Setup message in the Security menu. This message is then no longer displayed while the server's startup routine is in progress.

Prevent unauthorized system access

You can activate this protection by setting a system password in the Security menu.

Prevent unauthorized access to the settings of boards with their own BIOS

You can activate this protection by selecting the value Extended for the Setup Password Lock field in the Security menu.

Prevent the system from booting from the diskette drive

You can activate this protection by selecting the value Diskette Lock for the System Load field in the Security menu.

A26361-K647-Z102-3-7619 47

Page 54: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

BIOS Setup Security Functions Property and Data Protection

Prevent unauthorized writing of diskettes

To activate this protection, select the value Disabled for the Diskette Write field in the Security menu.

Protect BIOS from being overwritten

To activate this protection, select the value Disabled for the Flash Write field in the Security menu.

Protect the server from being switched on by an external device

To activate this protection, select the value Disabled for the Remote Power On field in the Security menu.

Protect the server from being switched off by a program

To activate this protection, select the value Disabled for the Soft Power Off field in the Security menu.

48 A26361-K647-Z102-3-7619

Page 55: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

6 Troubleshooting and TipsV CAUTION!

Refer to the safety notes in the manual for „Safety, Warranty, and Economics“ and the chapter “Installation” on page 17.

If a fault occurs, try to correct it as described:

– in this chapter– in the documentation of the connected devices– in the help systems of the software used.

If you fail to correct the problem, proceed as follows:

Ê Make a list of the steps and the circumstances that led to the fault. Also make a list of any error messages displayed.

Ê Switch the server off.

Ê Contact customer service.

6.1 Power-On Indicator Remains Dark

The power-on indicator remains dark after you switch on your device.

Power cord incorrectly connected

Ê Make sure that the power cable is correctly connected to the server and to the grounded power outlet.

Power supply overloaded

Ê Pull the power plug of the server out of the power outlet.

Ê Wait a few seconds, and plug the power plug into the power outlet again.

Ê Switch your server on.

A26361-K647-Z102-3-7619 49

Page 56: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Server Switches Itself Off Troubleshooting and Tips

6.2 Server Switches Itself Off

Server Management has detected an error

Ê In the ServerView program, check the error list or check the ErrorLog file using the SCU utility, and attempt to eliminate the error.

6.3 Screen Remains Blank

Monitor is switched off

Ê Switch on your monitor.

Screen has been blanked

Ê Press any key on the keyboard.

or

Ê Deactivate screen blanking (screen saver), and enter the appropriate password when necessary.

Brightness control is set to dark

Ê Set the brightness control to light. For detailed information, please refer to the operating manual supplied with your monitor.

Power cable or monitor cable not connected

Ê Switch off the monitor and the server.

Ê Check whether the power cable is properly connected to the monitor and to the power outlet.

Ê Check whether the monitor cable is properly connected to the server and monitor (if it is plugged in with a connector). If a separate graphics card is installed in the server, then the monitor cable must be connected to the graphics card.

Ê Switch on the monitor and the server.

50 A26361-K647-Z102-3-7619

Page 57: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Troubleshooting and Tips Flickering Stripes on Monitor Screen

6.4 Flickering Stripes on Monitor Screen

V CAUTION!

Switch off the server immediately.

Monitor does not support the set horizontal frequency

Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or the corresponding driver software for the screen controller for how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

6.5 No Screen Display or Display Drifts

The wrong horizontal frequency or resolution has been selected for the monitor or for the application program.

Ê Find out which horizontal frequency your monitor screen supports. You will find the horizontal frequency (also known as line frequency or horizontal deflection frequency) in the documentation for your monitor.

Ê Refer to the documentation for your operating system or corresponding driver software for the screen controller for how to set the correct horizontal frequency for your monitor, and follow the procedure accordingly.

A26361-K647-Z102-3-7619 51

Page 58: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

No Mouse Pointer Displayed on Screen Troubleshooting and Tips

6.6 No Mouse Pointer Displayed on Screen

Mouse driver not loaded

Ê Check whether the mouse driver is properly installed and is present when the application program is started. Detailed information can be found in the user manuals for the mouse, the operating system, or the application program.

Mouse controller disabled

The mouse controller on the system board must be enabled if you use the supplied mouse.

Ê Check in the BIOS Setup that the mouse controller is enabled.

6.7 Cannot Read or Write to Floppy Disk

Ê Check whether the write protection of the floppy disk is activated.

Ê In the BIOS Setup, check the entry for the floppy disk drive.

Ê In the BIOS Setup, check whether the diskette drive controller and write permissions are enabled (see “Related Publications” on page 69).

6.8 Time and/or Date Not Correct

Ê Set the time and/or date in the operating system or in the BIOS Setup.

I If the time and date are repeatedly wrong when you switch on your server, then the battery is flat. Change the lithium battery as described in the technical manual for the system board.

52 A26361-K647-Z102-3-7619

Page 59: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Troubleshooting and Tips System Will Not Boot

6.9 System Will Not Boot

The system will not boot after installing a new hard disk drive.

SCSI configuration incorrect (Ultra Wide SCSI Controller)

Ê In the SCSI configuration menu, check the settings for the hard disk drives (SCSI Device Configuration) and the settings under Advanced Configuration Options.

6.10 Drives Are Reported as "Dead"

This error message may occur when the server has a disk array controller:

SCSI cabling incorrect

Ê Make sure the SCSI cable connection and the SCSI channel assignment still correspond to the original state.

The disk array controller configuration is incorrect

Ê Check and correct the settings for the drives with the RAID configuration program.

Further information is provided in the manual for the disk array controller (see “Related Publications” on page 69).

6.11 Added Drive Reported Defective

This error message may occur when the server has a disk array controller.

Disk array controller is not configured for this hard disk drive

The drive was probably installed with the system switched off.

Ê Reconfigure the disk array controller for the hard disk drive. Information is contained in the documentation for the disk array controller (see also “Related Publications” on page 69).

A26361-K647-Z102-3-7619 53

Page 60: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Error Messages on the Screen Troubleshooting and Tips

6.12 Error Messages on the Screen

The meaning of the error message is contained on the PRIMERGY ServerBooks CD, Technical Manuals, System boards and in the documentation for the boards and programs used (see also “Related Publications” on page 69).

54 A26361-K647-Z102-3-7619

Page 61: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

7 System Components and Expansions

This chapter describes how to replace SCSI hard disk modules.

V CAUTION!

Please observe the safety information in chapter “Important Notes” on page 9.

V CAUTION!

If you do not wish to carry out hot plug operations, then shut down the operating system, switch off the server, and pull the power plug out of the power outlet.

7.1 SCSI Hard Disk Subsystem

The SCSI hard disk subsystem consists of the hard disk modules, the SCSI backplane and the SCSI controller.

You can mount up to three hard disk modules into the PRIMERGY L200 server. Only Ultra3 SCSI drives (LVD) with a 3.5 inch format, a maximum height of 1inch and a SCA interface are used. The hard disk drives are mounted in slide-in units which makes it very easy to insert or remove the hard disk. The slide-in units are equipped with a status indicator and an error indicator.

If a SCSI hard disk drive is operated on a disk-array controller (DAC) and belongs to a disk-array operated in RAID level 1 or level 5, a hard disk drive can be replaced during operation (hot-swapping). To swap a hard disk drive with the same or a higher capacity. A rebuild of the data on the new hard disk drive is performed automatically after the replacement, provided that the DAC is configured correctly. Refer to the information on the ServerBooks CD or in the DAC manual (see also “Related Publications” on page 69).

I In order to be able to recognize a hard disk drive’s capacity at once when replaced, several prefabricated stickers displaying imprinted storage capacities are provided with the server. Each hard disk module should be labeled with a sticker indicating the capacity of the installed hard disk drive. In case no suitable sticker is available, blank stickers for labeling are also provided. The stickers are color coded for an easier identifi-cation.

A26361-K647-Z102-3-7619 55

Page 62: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

SCSI Hard Disk Subsystem System Components and Expansions

The SCSI IDs of the hard disk modules are assigned by the SCSI backplane in the order 0, 1, 2 from left to right.

Notes on RAID levels

– RAID level 0 and 7Rebuild is not possible. If a hard disk drive fails, its data is lost.

– RAID level 1 and 5 without standby hard disk driveRebuild on the new disk is carried out automatically when the old disk is swapped.

– RAID level 1 with standby hard disk driveA standby hard disk drive is automatically enabled as a replacement for the defective hard disk drive, and the data of the defective disk is rebuilt on the standby disk.

Ê Read the documentation for the new hard disk drive.

7.1.1 Components and Indicators of the Hard Disk Module

The hard disk drives which can be ordered for the server are supplied already mounted in the hard disk modules. The slide-in units are equipped with a status indicator and an error indicator. Empty bays are covered with dummy covers.

V CAUTION!

A hard disk drive in the hard disk carrier may only be replaced by a service technician.

56 A26361-K647-Z102-3-7619

Page 63: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

System Components and Expansions SCSI Hard Disk Subsystem

Figure 15: Hard disk module and dummy cover

Function of the indicators

1 = Hard disk module (hard disk carrier with installed hard disk drive)

2 = IndicatorsHDD access (LED green)HDD error (LED orange)

3 = Handle for engaging and disengaging the hard disk module

4 = Locking button

5 = Ridge for the application of a sticker with the current drive identifier

6 = Dummmy cover

7 = Locking tabs

Green indictor: The green indicator lights up when a hard disk drive is being accessed. The hard disk module cannot be replaced at this time!

Orange indicator: The orange LED flashes when, in conjunction with a disk array controller, the configuration is being determined or a rebuild is being done. You may not replace the hard disk module at this time!The orange LED remains lit if the hard disk drive is deacti-vated and/or defective and can be replaced.

A26361-K647-Z102-3-7619 57

Page 64: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

SCSI Hard Disk Subsystem System Components and Expansions

7.1.2 Installing/Removing a SCSI Hard Disk Module

If a hard disk module is to be installed in a bay in which no hard disk module was previously installed, then the dummy cover must be removed from this bay beforehand.

Removing the dummy cover

Figure 16: Removing dummy cover

Ê Press the two locking tabs at the left and right on the dummy cover together (1) until the detent is released.

Ê Remove the dummy cover from the bay (2).

V CAUTION!

Keep the dummy module for future use. If the hard disk module is removed again and not replaced with a new module, then the dummy cover must be reinstalled due to cooling, the applicable EMC regulations (electromagnetic compatibility) and fire protection.

Installing the dummy cover

Ê Insert the dummy cover into the bay.

I Make sure that the dummy cover engages properly in the bay.

58 A26361-K647-Z102-3-7619

Page 65: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

System Components and Expansions SCSI Hard Disk Subsystem

Installing 1 inch hard disk module

Figure 17: Disengage the hard disk module

Ê Solve the locking mechanism (1) by pressing the locking button.

Ê Swing the handle of the hard disk module fully upwards (2).

A26361-K647-Z102-3-7619 59

Page 66: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

SCSI Hard Disk Subsystem System Components and Expansions

Figure 18: Installing hard disk module

Ê Insert the new hard disk module (1).

Ê Now swing the carrier handle of the hard disk module completely down to enable the locking mechanism to engage (2).

The SCSI IDs of the hard disk modules are assigned by the SCSI backplane (see section “SCSI Hard Disk Subsystem” on page 55).

60 A26361-K647-Z102-3-7619

Page 67: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

System Components and Expansions SCSI Hard Disk Subsystem

Removing 1 inch hard disk module

Figure 19: Removing hard disk drive

Ê Solve the locking mechanism by pressing the locking button (1).

Ê Swing the handle of the hard disk module fully upwards.

Ê Remove the hard disk module (2).

V CAUTION!

If a hard disk drive has been removed and no new drive is installed in its place, then install a dummy cover in the empty bay. Make sure that the dummy cover engages properly in the bay.

A26361-K647-Z102-3-7619 61

Page 68: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

SCSI Hard Disk Subsystem System Components and Expansions

7.1.3 Replacing a Hard Disk Module During Operation -Hot Swapping

V CAUTION!

A SCSI hard disk module may only be replaced during operation if the orange LED on the hard disk module remains lit.

V CAUTION!

Never pull out an internal hard disk module during operation if you are not sure that the hard disk drive operates on a disk array controller and is part of a disk array that operates in mode RAID level 1 or 5.

If you replace a hard disk module during operation, proceed as follows:

Ê Solve the locking mechanism of the hard disk module indicated as defective by pressing the locking button.

Ê Swing the handle of the hard disk module fully upwards.

Ê Pull out the hard disk module a few centimeters.

Ê Wait at least 60 seconds so that the disk array controller can recognize that a hard disk drive has been removed and that the hard disk can come to rest.

Ê Pull the hard disk module completely out.

Ê Solve the locking mechanism of the new hard disk module by pressing the locking button.

Ê Swing the handle of the new hard disk module fully upwards.

Ê Insert the new hard disk module in the bay.

Ê Now swing the carrier handle of the hard disk module completely down to enable the locking mechanism to engage.

The SCSI IDs of the hard disk modules are assigned by the SCSI backplane (see section “SCSI Hard Disk Subsystem” on page 55).

62 A26361-K647-Z102-3-7619

Page 69: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

AbbreviationsAC

Alternating current

ANSIAmerican National Standard Institut

ASR&RAutomatic Server Reconfiguration and Restart

BIOSBasic Input-Output System

BMCBaseboard Management Controller

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

DACDisk Array Controller

A26361-K647-Z102-3-7619 63

Page 70: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Abbreviations

DCDirect Current

DIMMDual Inline Memory Module

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCError Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EGBElektrostatisch Gefärdete Bauteile (components are in danger of electro-static)

EMCElectroMagnetic Compatibility

EMPEmergency Management Port

EMVElektomagnetische Verträglichkeit (electromagnetic compatibility)

EPPEnhanced Parallel Port

ESDElectroStatic Discharge (elektrostatische Entladung)

64 A26361-K647-Z102-3-7619

Page 71: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Abbreviations

FPCFront Panel Controller

FRUField Replaceable Unit

FSBFront Side Bus

GAMGlobal Access Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap-Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntergrated Drive Electronics

IRQInterrupt Request Line

LANLocal Area Network

A26361-K647-Z102-3-7619 65

Page 72: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Abbreviations

LBALogical Block Address

LCDLiquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

LWLLichtWellenLeiter (fiber optic cable)

MMFMulti Mode Fiber

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analysing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

RAMRandom Access Memory

66 A26361-K647-Z102-3-7619

Page 73: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Abbreviations

ROMRead-Only Memory

RSBRemote Service Board

RTCReal-Time Clock

RTDSRemote Test- und Diagnose-System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

SELSystem Event Log

SMISystem Management Interrupt

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

A26361-K647-Z102-3-7619 67

Page 74: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Abbreviations

USBUniversal Serial Bus

VGAVideo Graphics Adapter

68 A26361-K647-Z102-3-7619

Page 75: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Related PublicationsOn the delivered PRIMERGY ServerBooks CD you can find:

– the Operating Manual for the PRIMERGY L200 sever in five languages– all manuals listed below without the manual for „Safety,Warranty, and

Ergonomics“

Printed manuals are:

– the Operating Manual for the PRIMERGY L200 sever in english– the manual for „Safety,Guarantee and Ergonomics“

The PDF files for the manuals listed below canalso be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL:http://manuals.fujitsu-siemens.com

[1] Safety,Warranty, and Ergonomics

[2] 19-Zoll-Rack/19 inch rack Technisches Handbuch/Technical Manual

[3] DataCenter Rack Technisches Handbuch/Technical Manual

[4] PRIMECENTER Rack Technisches Handbuch/Technical Manual

[5] ServerView Software Servermangement Benutzerhandbuch/User Guide

[6] RemoteView Software Benutzerhandbuch/User Guide

[7] RemoteView Service Board Installationsanleitung/Installation Guide

[8] Systembaugruppe D1307/System Board D1307 Technisches Handbuch/Technical Manual

[9] BIOS setup Description

A26361-K647-Z102-3-7619 69

Page 76: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München
Page 77: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Index

Aaccessible drives 2, 32ASR&R 3availability 3

Bbatteries 11BIOS Setup

overwriting protection 48security functions 47

BIOS update 4boards with their own BIOS

preventing access 47

Ccables

connecting 29disconnecting 29

cage nut 21, 23CD-ROM drive 32, 35CE certification 6CE label 13Class A Compliance Statement 13components

hardware/software 1configuring 38connecting

cables 29devices 28server 29

consumables 15

Ddate, wrong 52dimensions 7disconnecting

cables 29disk array controller 3, 55

not configured 53

disposal 16drive

"dead" 53drives

indicators 35dummy cover

installing 58removing 58

EEDC 3electrical data 6electromagnetic compatibility 6, 13electrostatic discharge (ESD) 12EMC

(electromagnetic compatibility) 58EMC directive 6environmental conditions 7environmental protection 15error

drive "dead" 53flickering stripes

on monitor screen 51floppy disk

cannot be read/written 52no mouse pointer 52no screen display 51screen display drifts 51screen remains blank 50server switches itself off 50system not starting 53wrong date 52wrong time 52

error detection and correction 3error messages

on screen 54extension slots 3

A26361-K647-Z102-3-7619 71

Page 78: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Index

Ffailure

flickering stripes on monitor screen 51

floppy disk cannot be read/written 52

no mouse pointer 52no screen display 51screen display drifts 51screen remains blank 50server switches itself off 50system not starting 53wrong date 52wrong time 52

FCC statement 13flash EPROM 4floorstand server

standards 6technical data 6

floppy diskproblems with read/write 52write protection 48

floppy disk drive 32, 35front side 31frontside

operation panel 33

GGuided installation 40Guided Mode 40

Hhard disk drive 56

disk array controller 53error message 53indicators 57installing 58no system reboot 53removing 58, 61replacing 62

hard disk module 56indicators 56installing 59

hard disk subsystem 2, 55height units 21, 23hot-replace 55

Iidentification rating 18important notes 9indicator

power-on indicator remains dark 49

indicators 34, 35, 36installation 17installation with ServerStart 39

LLAN unlock tool 30laser, note 11lithium battery 11low voltage directive 6, 13

Mmeanings of the symbols 5monitor screen

flickering stripes 51mounting

rack 14rack server 14server 18

mouseno pointer 52

mouse controller, disabled 52mouse driver 52

Nnoise level 7notational conventions 5

Ooperating system

no start 53preventing start 47

operation controls 34operation panel 34

72 A26361-K647-Z102-3-7619

Page 79: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Index

options 4overwriting protection

BIOS Setup 48

Ppackaging 15power supply 2power-on indicator

remains dark 49prefailure Detection 3product safety 6

Rrack

mounting 14rack server

dimensions 7mounting 14standards 6technical data 6

RAID level 3, 56rear side

indicators 36recycling 16remote power-on, preventing 48RemoteView 4RemoteView Service Board 4replacing a hard disk drive during

operation 62replicated installation 42routing cables 27RSB 4

Ssafety 9saving energy 15screen

display drifts 51error messages 54flickering stripes 51no display 51remains blank 50

SCSI-ID 62security menu, BIOS setup 47

servercleaning 45configuring 38dimensions 7electrical data 6height units 21, 23mounting in the rack 18preventing switch off

by a program 48safety standards 6standards 6switches itself off (error) 50switching on/off 37technical data 6transport 14weight 7

server management 3ServerStart 4, 38

installation 39sever

unpacking 17sliding rail 23, 24slimline CD-ROM drive 32, 35slimline floppy disk drive 32, 35spring nut 21, 23standards 6support bracket 18, 21switching on/off 37system

no reboot 53system board 2system boot

preventing 47

Ttarget group 5technical data 6time, wrong 52transport

server 14trobleshooting 49trouble

drive "dead" 53

A26361-K647-Z102-3-7619 73

Page 80: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Index

Uunpacking 17

Vventilation interval 7

Wweight 7write protection

BIOS Setup 48floppy disks 48

74 A26361-K647-Z102-3-7619

Page 81: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Comments on PRIMERGY L200Server System

A26361-K647-Z102-3-7619

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MunichGermany

Fax: (++49) 700 / 372 00000

Internet: [email protected]://manuals.fujitsu-siemens.com

Page 82: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München
Page 83: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Comments on PRIMERGY L200Server System

A26361-K647-Z102-3-7619

CommentsSuggestionsCorrections

Submitted by

Fujitsu Siemens Computers GmbHUser Documentation81730 MunichGermany

Fax: (++49) 700 / 372 00000

Internet: [email protected]://manuals.fujitsu-siemens.com

Page 84: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München
Page 85: PRIMERGY L200 Server System - CNET Contentcdn.cnetcontent.com/06/4e/064e8a52-e208-4407-96f3-24ca03c65dc0.pdf · PRIMERGY L200 Server System Jacob Fujitsu Siemens Computers GmbH München

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009