Pricelist 2019-2020

Applied Systems

Prices and technical information for Applied Systems

Page 2: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

2

Type Refrigerant Compressor Material Capacity Page

Key information - Ecodesign directive and Energy Labelling

4

Witness Testing 5

Air cooled chillersAir cooled mini inverter chiller R-410A Swing EWAQ-A & EWAQ-B 4-13 kW 11

Air cooled mini inverter heat pump R-410A Swing EWYQ-A & EWYQ-B 4-13 kW 12

Air cooled scroll inverter chiller R-410A Scroll EWAQ-CW 17-64 kW 13

Air cooled scroll inverter heat pump R-410A Scroll EWYQ-CW 17-64 kW 14

Air cooled scroll inverter heat pump - split version R-410A Scroll SEHVX-BW & SERHQ-BW1 20-64 kW 15

Hydronic connection examples 16

Product description - Air cooled chiller EWAQ-G/EWYQ-G 18

Air cooled chiller - standard efficiency - standard noise R-410A Scroll EWAQ-G-SS 75-155 kW 19

Air cooled chiller - standard efficiency - reduced noise R-410A Scroll EWAQ-G-SR 75-155 kW 20

Air cooled chiller - high efficiency - standard noise R-410A Scroll EWAQ-G-XS 80-150 kW 21

Air cooled chiller - high efficiency - reduced noise R-410A Scroll EWAQ-G-XR 80-150 kW 22

Air cooled heat pump - high efficiency - standard noise R-410A Scroll EWYQ-G-XS 75-160 kW 23

Air cooled heat pump - high efficiency - reduced noise R-410A Scroll EWYQ-G-XR 75-165 kW 24

EWAT-B- Multi scroll Air cooled chiller range with R-32 refrigerant

25

Air cooled Chiller - standard efficiency - standard noise R-32 Scroll EWAT-B-SS 85-205 kW 26

Air cooled Chiller - standard efficiency - low noise R-32 Scroll EWAT-B-SL 85-205 kW 28

Air cooled Chiller - standard efficiency - reduced noise R-32 Scroll EWAT-B-SR 85-205 kW 30

Air cooled Chiller - high efficiency - standard noise R-32 Scroll EWAT-B-XS 85-200 kW 32

Air cooled Chiller - high efficiency - low noise R-32 Scroll EWAT-B-XL 85-200 kW 34

Air cooled Chiller - high efficiency - reduced noise R-32 Scroll EWAT-B-XR 85-200 kW 36

Water cooled chillersWater cooled chiller R-410A Scroll EWWQ-KBW1N 14-64 kW 38

Water cooled chiller R-410A Scroll EWWQ-KBW1M 98-192 kW 39

Product description - water cooled chiller EWW(H)Q-G(L)-SS 40

Water cooled chiller - standard efficiency -

standard noise - one refrigerant circuit R-410A Scroll EWWQ-G-SS 90-360 kW 41

Water cooled heat pump - standard efficiency R-410A Scroll EWHQ-G-SS 100-400 kW 42

Water cooled chiller - standard efficiency -

standard noise - two refrigerant circuits R-410A Scroll EWWQ-L-SS 180-330 kW 43

Condenserless chillersCondenserless chiller R-410A Scroll EWLQ-KBW1N 14-64 kW 44

Condenserless chiller - standard efficiency -

standard noise - one refrigerant circuit R-410A Scroll EWLQ-G-SS 90-360 kW 45

Condenserless chiller - standard efficiency -

standard noise - two refrigerant circuits R-410A Scroll EWLQ-L-SS 180-330 kw 46

intelligent Chiller Manager - iCM 47

Fan coil Low ESP duct FWE-C 2 - 10 kW 49

Medium ESP duct FWB-B 2- 10 kW 50

Table of contents

NEWNEWNEWNEWNEWNEW

NEW

NEW

NEW

Page 3: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 3

NOTE:

The pricelist is valid from 1 April 2019 till 31 March 2020. All prices are list prices in Lei and excl. VAT.All prior pricelists are not valid anymore. We reserve the right for printing errors and model changes. The LOT1&2 regulation requires the manufacturers to publish additional

energy efficiency data for some products shown in this literature. From September 2015, these required efficiency data can be publicly viewed and downloaded from the

following free access website: https://www.daikin.ro/ro_RO/about/daikin-innovations/seasonal-efficiency.html

Type Refrigerant Compressor Material Capacity Page

Medium ESP duct / BLDC FWP-A 2 – 7 kW 52

Medium ESP duct / BLDC FWN-A 4 - 10 kW 53

High ESP flexi duct FWD-A 4 - 18 kW 55

Cassette 600x600 FWF-C 2 - 4 kW 57

Wall mounted FWT-C 2 - 6 kW 57

Cassette 900×900 FWG-A 5-11 kW 58

Cassette 600x600 FWF-B 2 - 5 kW 59

Cassette 900x900 FWC-B 6- 9 kW 59

Floor standing FWV-D 1 - 10 kW 62

Flexi type FWL-D 1 - 10 kW 63

Flexi concealed FWM-D 1 - 10 kW 64

Floor standing / BLDC FWZ-A 2 - 8 kW 69

Flexi type / BLDC FWR-A 2 - 8 kW 70

Flexi concealed / BLDC FWS-A 2 - 8 kW 71

Condensing unit heat pump Inverter R-410A Scroll ERQ 11-28 kW 75

Pre-sized fresh air solution ADT-FDI 76

Air Handling Units - AHU 77Modular Light / Smart ALB-R/LB(S) 100 - 3400 m³/h 79

Daikin Rooftops 82Rooftop R-410A Scroll UATYQ-ABAY1 20-115 kW 87

Rooftop R-410A Scroll UATYQ-AFC2Y1 20-115 kW 88

Rooftop R-410A Scroll UATYQ-AFC3Y1 20-115 kW 89

Overview: Air cooled chiller portfolio 90

Overview: Water cooled and condenserless unit portfolio 92

Total solution productsAir Cooler, Air Handling Unit, Dry Cooler & Condenser

Cooling Tower, Compressor Service 94

Measuring conditions 95

Daikin Service 96Commissioning 97

Maintenance 98

E-Parts, Service Academy 99

Remote Monitoring 100

NEW

Page 4: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

4

Ecodesign Directive and Energy Labels

The Ecodesign Directive defines the minimum standards for the environmental characteristics of heaters, water heaters and combi appliances. From 26 September 2015, heat generators of up to 70 kW output and tanks of up to 500 litres must be marked with a label showing their energy efficiency. This applies to all individual products (product label) and heating systems (package label) brought onto the market from this date. In addition, a product datasheet containing detailed information must be made available for each item.

From green to red

The principle is well-known from refrigerators, washing machines and TV sets: Devices and appliances are split into efficiency classes on a scale from A+++ to G. Dark green represents the highest level of efficiency, dark red the lowest. The scales differ between the individual product groups.

Identical across Europe

The Ecodesign Directive for heat generators and water heaters, and the obligation to identify products and system solutions with energy labels, will apply to all member states of the European Union. The aim is to promote the manufacture and development of more environmentally responsible and energy efficient heating systems and to simplify comparisons for consumers.

Heat generators

2015

2019

Water heaters Packages

2015

2017

2015

Key Information

Applied systems: products in scope Since 2013, all air conditioners and air-to-air heat pumps under 12 kW are in scope of this Eco-Design directive.

Since 26 September 2015, heat generators for space heating (LOT 1) also need to comply to these 20-20-20 targets. For the applied systems market it means that all heat pumps below 400 kW need to comply to minimum efficiency requirements. Heat pumps below 70 kW must be marked with a product energy label.

Since 26 September 2017, second tier of LOT 1 came into force, requiring minimum seasonal efficiency (SCOP) for the air to water & water to water heat pumps up to 400 kW.

Since 2018, the Ecodesign Directive sees ENER LOT 21 came into force to increase energy efficiency and reduce carbon emissions throughout Europe. The products in scope are: ʯ Air conditioners - all air conditioners over 12 kW, with specific requirements for both cooling and heating.

ʯ Cooling only chillers up to 1.500kW. ʯ Reversible chillers from 400 kW to 1.500kW (reversible chillers up to and including 400kW are excluded from the regulation as being covered by directive (EC) 813/2013 with regard to Ecodesign requirements for space heaters and combination heaters).

ʯ Heating only chillers are excluded from the LOT 21, with no minimum heating requirements specified.

Our service Daikin helps its partners to meet their obligations regarding the Ecodesign Directive and energy labelling. Labels, product and technical fiches for each individual product are available as downloads at any time from the Energy Label Generator at http://emea.intpre.daikineurope.com/energylabel/Lot1-2

Page 5: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 5

Witness testingPeace of mind system integration

During witness testing even the toughest design conditions can be simulated. Customers and consultants can appreciate product performance before its delivery, ensuring “peace of mind” chiller integration in the whole project.

Each day, the solutions offered by Daikin Applied Europe ensure people the best configuration for their thermic comfort. Our solutions for process cooling and heating are worldwide requested. Any application can be served, resulting in a wide range of products available for our customers. We are industry leaders in air cooled and water cooled chiller technologies. All our efforts result in dedicated solutions tailored to application peculiarities. Our performance in each condition can be shared with customers during witness tests.

We have specific competencies and state of the art testing facilities to pursue these goals.

The new Daikin Applied Europe testing facilities in Cecchina factory (Rome, Italy) include:

ʯ A newly built climatic test chamber ʯ 3 test stands dedicated to water cooled chillers ʯ Customer Lounge, from where testing can be viewed in all comfort

Page 6: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

6

Testing facilities in Daikin Applied Europe

The state-of the-art testing centre follows a

rigorous set of procedures to ensure proper

operation of Daikin products in any environment.

The new testing regime has been independently

verified and accredited to EN 14511:2013,

ISO 9614:2009 and other major recognised

European and American HVACR industry

standards. In addition, the climatic chamber

has been approved by the Air Conditioning,

Heating and Refrigeration Institute (AHRI), with

tests on air-cooled units for the Eurovent testing

campaign being conducted in this new Daikin

facility.

The range of tests that could be performed in the new chamber is very wide. It can be summarized in:

Eurovent and AHRI conditions at full load and part load

Customized full load and part load points, including: ʯ High ambient temperature installations: up to +52 °C ʯ Extremely low ambient temperature: down to -15 °C ʯ Negative evaporator leaving water temperature conditions: down to -8 °C with glycol solutions

ʯ Heat recovery and heat pump tests ʯ 4-6 pipes units ʯ Free cooling ʯ Acoustic tests

ʯ Voltage range: 380 – 400 – 440 – 690 V ʯ Frequency range: 50 – 60 Hz

Up to

2000 kW in cooling

at the forefront of testing

New Climatic Chamber

Page 7: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 7

Each application can be simulated. From comfort cooling conditions (residential / office / commercial buildings / hospitals) to highly customized chillers for industrial process cooling applications (food / pharma / refrigerated warehouses / data centers, etc.). Chillers for rental cooling purposes can be tested in our facility, in different expected operating conditions.

EWYD-4Z Multipurpose units

4 and 6 pipes layouts can be tested

NEW R1234ze chiller EWAH-TZ B

Up to 1060 kW – 20 FANS

Up to 30 FANS chiller EWAD-T B

Cooling capacity up to 2000 kW

Application: Pharma

Unit: EWADC11TZ-XS B2

Cooling load: 695 kW

Conditions:Chilled water in/out: 0/-5 °CAmbient temperature: 42°C

Tests performed:Full load + 3 part loadsTesting time: 1 day

Application: Bank headquarters

Unit: EWYD580BZ-SS

Cooling load: 580 kWHeating load: 618 kW

Conditions:Chilled water in/out: 12 / 7 °C at 35 °C ambientHeated water in/out: 40 / 45 °C at 7 °C ambient

Tests performed:Full load in cooling & heating50% part load in cooling Acoustic test in cooling – full loadTesting time: 1 day

Application: Hospital

Unit: EWYD6504Z-XR A2

Cooling load: 756 kWHeating load: 751 kW

Conditions:Chilled water in/out: 12 / 6 °C at 38°C ambientHeated water in/out: 40 / 45 °C at 5 °C ambient

Tests performed: Full load in cooling & heatingAcoustic test in cooling – full loadTesting time: 1 day

The new climatic chamber enables testing of the entire aircooled chiller range, in any design condition.

Here are only a few examples of successful witness tests:

Page 8: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

8

Cooling applications can be simulated in many conditions. From small-medium sized comfort cooling conditions (residential / office / commercial buildings) to highly customized chillers for industrial process cooling applications (food / pharma, etc.) and up to large

Our chiller testing facility offers the most advanced testing technology for water cooled units. 3 test stands are available for

witness testing purposes, up to 2 – 4 – 11 MW cooling capacity. The largest capacity test stand is also AHRI approved.

Testing facilities in Daikin Applied Europe

Water cooled test stands

public buildings and district cooling applications. Chillers for marine applications can be tested in our facility, ensuring complete integration of the chiller in the ship’s HVAC system.

Power supply conditions can be set according to an extensive range:Voltage: 380 – 400 – 460 – 690 – 3000 – 3300 – 4160 – 6000 – 6600 – 10000 – 11000 – 13200 – 13800 VFrequency– 60 Hz

Application: Courthouse

Unit: EWWDC21VZ-XS A2

Cooling load: 1736 kW

Conditions:Chilled water in/out: 10 / 5 °CCondenser water in/out: 40 / 45 °CPower supply: 400 V / 50 Hz

Tests performed: Full load + 3 part loadsTesting time: 1 day

Application: Marine – cruise vessel

Unit: DWDC

Cooling load: 6000 kW

Conditions:Chilled water in/out: 12 / 6 °CCondenser water in/out: 32 / 38 °CPower supply: 11000 V/ 60 Hz

Tests performed: Full load + 3 part loadsTesting time: 1 day

Application: District cooling

Unit: WCT

Cooling load: 11 MW

Conditions:Chilled water in/out: 10 / 5 °CCondenser water in/out: 35 / 39 °CPower supply: 11000 V/50 Hz

Tests performed: Full load + 3 part loadsTesting time: 1 day

Here are only a few examples of successful witness tests:

Page 9: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 9

Power supply conditions can be set according to an extensive range:Voltage: 380 – 400 – 460 – 690 – 3000 – 3300 – 4160 – 6000 – 6600 – 10000 – 11000 – 13200 – 13800 VFrequency– 60 Hz

We elevate witness testing experience to a higher level. The dedicated lounge rooms ensure remote

data log and monitoring from test stands. Product control and open discussion on product and design

characteristics can then be fulfilled comfortably.

Customer Lounge

Product performance can be confirmed from the comfort of your chair. Details can be observed from the webcams all around the unit, ensuring customer expectations and safety. As well, the unit under testing can be directly checked through the glass.

Our customers are free to select what should be displayed on our monitors just by clicking on our tablet

Page 10: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

10

Page 11: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 11

Unit size (1 phase) EWAQ 004BVP 005BVP 006BVP 008BVP 009ACV3P 010ACV3P 011ACV3PPrice(1) Lei 13.496,- 14.709,- 15.762,- 17.418,- 19.434,- 20.579,- 22.110,-Cooling capacity(2) kW 4,00 4,93 5,88 7,95 8,6 9,6 11,1EER 3,14 3,06 3,15 3,1 3,05 2,93 2,85ESEER 4,45 4,49 5,25 5,24 4,31 4,3 4,33Sound power level dB(A) 63,0 64,2 69 69 64 64 64Supply voltage (1-phase) V~ 230 230 230 230 230 230 230

Options

OP10Evaporator heater tape including better insulation of the hydraulic

Lei 1.729,- 1.729,- 1.710,- 1.710,- 2.861,- 2.861,- 2.861,-

EK2CB07CV3

Option box, requires EKCB07CV3 Lei 1.035,- 1.035,- 1.035,- 1.035,- n/a n/a n/a

EKCB07CV3 Control box Lei 1.035,- 1.035,- 1.035,- 1.035,- n/a n/a n/aEKRP1HBA digital I/0 PCB

Additional board with operating or fault message output, fan operating message, release contact for additional heating

Lei n/a n/a n/a n/a 593,- 593,- 593,-

Unit size (3 phase) EWAQ 009ACW1P 011ACW1P 013ACW1PPrice Lei 20.273,- 22.295,- 23.617,-Cooling capacity(2) kW 9,1 11,1 13,3EER 2,99 2,85 2,57ESEER 4,43 4,44 4,36Sound power level dB(A) 64 64 66Supply voltage (3-phases) V~ 400 400 400

Options

OP10Evaporator heater tape including better insulation of the hydraulic

Lei 2.861,- 2.861,- 2.861,-

EKRP1HBA digital I/0 PCBAdditional board with operating or fault message output, fan operating message, release contact for additional heating

Lei 593,- 593,- 593,-

Notes:

(1) Pump integrated; (2) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

EWAQ-A/B ʯ Inverter controlled swing compressors with refrigerant R410a ʯ High ESEER thanks to inverter technology, integrated hydronics. ʯ Application range cooling air side + 10°C to + 43°C ʯ Application range cooling water side + 5°C to + 20°C ʯ Built-in Hydraulic kit: no buffer tank required, standard inverter driven pump, main flow sensor and switch included.

ʯ Expansion vessel included ʯ Control panel included

Air cooled mini inverter chiller

Page 12: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

12

EWYQ-A/B ʯ Inverter controlled swing compressors with refrigerant R410a ʯ High ESEER thanks to inverter technology ʯ Application range cooling air side +10°C to +43°C ʯ Application range cooling water side +5°C to +22°C ʯ Application range heating air side -20°C to +25°C ʯ Application range heating water side +15°C to +55°C ʯ Built-in Hydraulic kit: no buffer tank required, standard inverter driven pump, main flow sensor and switch included.

ʯ Expansion vessel included ʯ Control panel included

Air cooled mini inverter heat pump

Unit size (3 phase) EWYQ 009ACW1P 011ACW1P 013ACW1PPrice Lei 23.246,- 25.231,- 26.662,-Cooling capacity(2) kW 9,1 11,1 13,3EER 2,99 2,85 2,57 ESEER 4,43 4,44 4,36Heating capacity(3) kW 10,9 12,4 13,9COP 3,28 3,27 3,25Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency) % 126 134 130

SCOP 3,22 3,41 3,30Seasonal space heating eff. class A+ A+ A+

Sound power level dB(A) 64 64 66Supply voltage (3-phases) V~ 400 400 400

Options

OP10Evaporator heater tape including better insulation of the hydraulic

Lei 2.861,- 2.861,- 2.861,-

EKRP1HBAdigital I/0 PCBAdditional board with operating or fault message output, fan operating message, release contact for additional heating

Lei 593,- 593,- 593,-

Notes:

(1) Pump integrated; (2) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011 ; (3) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

Unit size (1 phase) EWYQ 004BVP 005BVP 006BVP 008BVP 009ACV3P 010ACV3P 011ACV3PPrice(1) Lei 15.005,- 16.344,- 17.522,- 19.358,- 22.371,- 23.552,- 24.972,-Cooling capacity(2) kW 4,00 4,93 5,88 7,95 8,6 9,6 11,1EER 3,14 3,06 3,15 3,10 3,05 2,93 2,85 ESEER 4,45 4,49 5,25 5,24 4,31 4,3 4,33Heating capacity(3) kW 4,11 4,99 6,14 8,08 9,9 11,4 12,9COP 3,44 3,41 3,51 3,49 3,3 3,29 3,27Space heating

Average climate water outlet 55°C

ηs (Seasonal space heating efficiency) % 114 118 124 124 126 131 134

SCOP 2,92 3,01 3,19 3,17 3,22 3,34 3,41Seasonal space heating eff. class A+ A+ A+ A+ A+ A+ A+

Sound power level dB(A) 63 64 69 69 64 64 64Supply voltage (1-phase) V~ 230 230 230 230 230 230 230

Options

OP10Evaporator heater tape including better insulation of the hydraulic

Lei 1.729,- 1.729,- 1.710,- 1.729,- 2.861,- 2.861,- 2.861,-

EK2CB07CV3

Option box, requires EKCB07CV3 Lei 1.035,- 1.035,- 1.035,- 1.035,- n/a n/a n/a

EKCB07CV3 Control box Lei 1.035,- 1.035,- 1.035,- 1.035,- n/a n/a n/a

EKRP1HBA digital I/0 PCBAdditional board with operating or fault message output, fan operating message, release contact for additional heating

Lei n/a n/a n/a n/a 593,- 593,- 593,-

Page 13: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 13

Unit size (without pump) EWAQ-CWN 016 021 025 032 040 050 064Price Lei 36.764,- 43.278,- 48.810,- 56.304,- 74.468,- 82.966,- 95.804,-Unit size (with standard pump) EWAQ-CWP 016 021 025 032 040 050 064Price Lei 40.730,- 47.357,- 52.973,- 61.701,- 80.168,- 88.794,- 101.846,-Unit size (with high lift pump) EWAQ-CWH 016 021 025 032 040 050 064Price Lei 42.306,- 48.932,- 54.548,- 63.842,- 82.390,- 91.037,- 104.088,-Cooling Capacity (MAX)(3) EWYQ - CWN(1) / CWP(2) kW 20,0 / 20,2 25,0 / 25,2 30,1 / 30,3 37,6 / 37,8 50,1 / 50,3 60,1 / 60,3 75,2 / 75,3Cooling capacity (nominal)(3) EWAQ - CWN / CWP kW 16,8 / 17,0 21,0 / 21,2 25,3 / 25,5 31,6 / 31,8 42,1 / 42,3 50,5 / 50,7 63,2 / 63,3ESEER (nominal) EWAQ - CWN(1) / CWP(2) 4,37 / 4,85 4,26 / 4.70 4,17 / 4,57 3,87 / 4,10 4,28 / 4,40 4,18 / 4,36 3,87 / 4,05Sound power level dB(A) 78 78 78 80 81 81 83

OptionsOP10 Evaporator electric heater Lei 2.986,- 2.988,- 2.985,- 2.990,- 3.756,- 3.755,- 3.755,-OPZL Low leaving water operation down to -10 °C Lei 2.236,- 2.238,- 2.235,- 2.229,- 2.983,- 2.983,- 2.983,-

KitEKRP1AHT

Additional board for external control, on/off device, heating /cooling switch

Lei 607,- 607,- 607,- 607,- 607,- 607,- 607,-

EKRUAHT

Additional control unit Lei 891,- 891,- 891,- 891,- 891,- 891,- 891,-

BHGP26A1

Digital pressure display Lei 2.677,- 2.677,- 2.677,- 2.677,- 2.677,- 2.677,- 2.677,-

DTA104A62

Additional board for demand and noise reduction

Lei 2.292,- 2.292,- 2.292,- 2.292,- 2.292,- 2.292,- 2.292,-

RTD-W

Modbus interface Lei 1.906,- 1.906,- 1.906,- 1.906,- 1.906,- 1.906,-- 1.906,-

EWAQ-CW ʯ Inverter controlled swing compressors with refrigerant R410a ʯ High efficiency with leader-of-class ESEER. ʯ No buffer tank required for standard applications ʯ Application range cooling air side -5°C to +43°C ʯ Application range cooling water side -10°C to +20°C ʯ Communication to the building management system via RTD-W module

ʯ Hydraulic module with integrated pump and without pump available

ʯ Expansion vessel, flow controller, water filter, shut-off valve, drain/filling valve, control panel included

Air cooled scroll inverter chiller

Notes:

(1) EWYQ-CWN: Version without pump

(2) EWYQ-CWP: Version with pump

(3) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

Page 14: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

14

Unit size (without pump) EWYQ-CWN 016 021 025 032 040 050 064Price Lei 42.275,- 49.771,- 56.138,- 64.740,- 85.616,- 95.386,- 110.167,-Unit size (with standard pump) EWYQ-CWP 016 021 025 032 040 050 064Price Lei 46.326,- 53.944,- 60.408,- 70.267,- 91.501,- 101.422,- 116.433,-Unit size (with high lift pump) EWYQ-CWH 016 021 025 032 040 050 064Price Lei 47.902,- 55.519,- 61.984,- 70.733,- 93.724,- 103.644,- 118.674,-Cooling capacity (MAX)(3) EWYQ - CWN(1) / CWP(2) kW 20,0 / 20,02 25,0 /25,2 30,1 / 30,3 37,6 / 37,8 50,1 / 50,3 60,1 / 60,3 75,2 / 75,3Cooling capacity (nominal)(3) EWYQ - CWN(1) / CWP(2) kW 16,8 / 17,0 21,0 / 21,2 25,1 / 25,5 31,6 / 31,8 42,1 / 42,3 50,5 / 50,7 63,2 / 63,3ESEER (nominal) EWYQ - CWP(1) / CWP(2) 4,37 / 4,85 4,26 / 4,70 4,17 / 4,57 3,87 / 4,10 4,28 / 4,40 4,18 / 4,36 3,87 / 4,05Heating capacity (MAX)(4) EWYQ - CWN(1) / CWP(2) kW 20,0 / 19,8 25,0 / 24,8 29,9 / 29,7 37,4 / 37,2 49,9 / 49,7 59,9 / 59,7 74,9 / 74,7Heating capacity (nominal)(4) EWYQ - CWN(1) / CWP(2) kW 16,8 / 16,6 21,0 / 20,8 25,1 / 24,9 31,4 / 31,2 41,9 / 41,7 50,3 / 50,1 62,9 / 62,7COP (nominal) EWYQ - CWN / CWP 3 / 3,02 3,05 / 3,07 2,87 / 2,91 2,91 / 2,93 3,06 / 3,03 2,87 / 2,88 2,91 / 2,93Space heating

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency) % 147(1)/144(2) 148(1)/154(2) 138(1)/139(2) 135(1)/138(2) 149(1)/149(2) 139(1)/139(2) 135(1)/138(2)

SCOP 3,75(1)/3,68(2) 3,78(1)/3,93(2) 3,53(1)/3,55(2) 3,45(1)/3,53(2) 3,80(1)/3,80(2) 3,55(1)/3,55(2) 3,45(1)/3,53(2)Seasonal space heating eff. class A+(1)/A+(2) A++(1)/A++(2) A+(1)/A+(2) A+(1)/A+(2) A+(1)/A+(2) A+(1)/A+(2) A+(1)/A+(2)

Sound power level dB(A) 78 78 78 80 81 81 83

OptionsOP10 Evaporator electric heater Lei 2.982,- 2.987,- 2.989,- 2.985,- 3.757,- 3.759,- 3.754,-OPZL Low leaving water operation down to -10 °C Lei 2.232,- 2.238,- 2.239,- 2.235,- 2.985,- 2.987,- 2.982,-

KitEKRP1AHT

Additional board for external control, on/off device, heating /cooling switch

Lei 607,- 607,- 607,- 607,- 607,- 607,- 607,-

EKRUAHT

Additional control unit Lei 891,- 891,- 891,- 891,- 891,- 891,- 891,-

BHGP26A1

Digital pressure display Lei 2.677,- 2.677,- 2.677,- 2.677,- 2.677,- 2.677,- 2.677,-

DTA104A62

Additional board for demand and noise reduction

Lei 2.292,- 2.292,- 2.292,- 2.292,- 2.292,- 2.292,- 2.292,-

RTD-W

Modbus interface Lei 1.906,- 1.906,- 1.906,- 1.906,- 1.906,- 1.906,- 1.906,-

EWYQ-CW ʯ Inverter controlled swing compressors with refrigerant R410a ʯ Wide operation range, ambient temperature in heating down to -15°C

ʯ No buffer tank required for standard applications ʯ Application range cooling air side -5°C to +43°C ʯ Application range cooling water side -10°C to +20°C ʯ Application range heating air side -15°C to +35°C ʯ Application range heating water side +25°C to +50°C ʯ Communication to the building management system via RTD-W module

ʯ Hydraulic module with integrated pump and without pump available

Air cooled scroll inverter heat pump

Notes:

(1) EWYQ-CWN: Version without pump

(2) EWYQ-CWP: Version with pump

(3) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(4) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

ʯ Expansion vessel, flow controller, water filter, shut-off valve, drain/filling valve, control panel included

Page 15: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 15

Unit size 20 32 40 64Indoor unit 1× SEHVX20BW 1× SEHVX32BW 1× SEHVX40BW 1× SEHVX64BWOutdoor Units 1× SERHQ020BW1 1× SERHQ032BW1 2× SERHQ020BW1 2× SERHQ032BW1Indoor unit Price per each Lei 22.037,- 24.628,- 25.823,- 26.290,-Outdoor unit Price per each Lei 32.977,- 46.448,- 32.977,- 46.448,-Unit Price per each (indoor + outdoor(s)) Lei 55.015,- 71.077,- 91.778,- 119.186,-Cooling Capacity (nominal)(1) kW 21,2 31,8 42,3 63,3Cooling Capacity (maximum)(1) kW 25,2 37,8 50,3 75,3EER 2,84 2,50 2,80 2,48ESEER 4,70 4,10 4,40 4,05Heating Capacity (nominal)(2) kW 20,8 31,2 41,7 62,7Heating Capacity (maximum)(2) kW 24,8 37,2 49,7 74,7COP 3,07 2,93 3,03 2,93Space heating Average

climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 154 138 149 138

SCOP 3,93 3,53 3,80 3,53Seasonal space heating eff. class A++ A+ A+ A+

Sound power level (outdoor unit / each) dB(A) 78 80 81 83

Standard Options SEHVX20BW SEHVX32BW SEHVX40BW SEHVX64BWStandard Hydraulic packageOne centrifugal pump

Lei including as standard including as standard including as standard including as standard

Kit Design size 020 032 040 064EKRP1AHT

Additional board for external control, on/off device, heating /cooling switch

Lei 607,- 607,- 607,- 607,-

DTA104A62

Additional board for demand and noise reduction

Lei 2.292,- 2.292,- 2.292,- 2.292,-

RTD-W

Modbus interface Lei 1.906,- 1.906,- 1.906,- 1.906,-

EKCC-WAdditional module for cascade control of up to 16 EWAQ ** devices including power supply

Lei 3.639,- 3.639,- 3.639,- 3.639,-

SEHVX-BW ʯ Inverter controlled swing compressors with refrigerant R410a ʯ Wide operation range, ambient temperature in heating down to -15°C

ʯ No buffer tank required for standard applications ʯ Application range cooling air side -5°C to +43°C ʯ Application range cooling water side +5°C to +20°C ʯ Application range heating air side -15°C to +35°C ʯ Application range heating water side +25°C to +50°C ʯ Communication to the building management system via RTD-W module

ʯ Hydraulic module with integrated pump and without pump available

ʯ Expansion vessel, flow controller, water filter, shut-off valve, drain/filling valve, control panel included

Air cooled scroll inverter heat pump - split version

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) Heating: Ta DB/WB 7/6°C - LWC 35°C (DT = 5°C), data according EN 14511: 2011

ʯ Distance between outdoor and indoor unit: max 30 meters ʯ Height difference between outdoor and indoor unit: max 10 meters

Page 16: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

16

EWYQ-CWPAn example scheme of the hydronic connection for the unit EWYQ-CWP is shown below. In the picture 1 the unit is equipped with a standard pump.

SEHVX-BWAn example scheme of the hydronic connections for the units SEHVX-BW/ SERHQ-BW1 is shown in Picture 2 & Picture 3.

Picture 2 – outdoor unit SERHQ020/032BW1 (size 20 or 32) with the hydronic connection to the related indoor unit SEHVX20/32BW.

Picture 3 - two outdoor units SERHQ020/032BW1 (size 40 or 64) with the hydronic connection to the related indoor unit SEHVX40/64BW. As seen from the scheme, these materials consist of two outdoor units.

Hydronic connection examples

Water/Glycol Mixture

Picture 1

Outdoor UnitEWYQ-CWP

DAG

P/HP

Page 17: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 17

Water line

Water line

Indoor UnitSEHVX20BW/SEHVX32BW

Indoor UnitSEHVX40BW/SEHVX64BW

Outdoor UnitSERHQ020BW1/SERHQ032BW1

Outdoor UnitSERHQ020BW1/SERHQ032BW1

Outdoor UnitSERHQ020BW1/SERHQ032BW1

Refrigerant line

Refrigerant line

DAG

DAG

P/HP

P/HP

Picture 2

Picture 3

Page 18: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

18

Out

side

tem

pera

ture

[o C]

50 cooling mode

40

30

20

10

0

-10

-20-15 -10 -5 0 5 10 15 20

Evaporator leaving water temperature [oC]

Out

side

tem

pera

ture

[o C]

50 cooling mode

40

30

20

10

0

-10

-20-15 -10 -5 0 5 10 15 20

Evaporator leaving water temperature [oC]

Cond

ense

r lea

ving

wat

er te

mpe

ratu

re [°

C]

55 heating mode

50

45

40

35

30

25

20-20 -15 -10 -5 0 5 10 15 20 25

Outside air tempeature [°C]

Air cooled chiller

EWAQ-G/ EWYQ-G › Compact Air Cooled chiller with Scroll compressors › Refrigerant R410A › Evaporator as plate heat exchanger › Condenser as Microchannel heat exchanger › Certified by Eurovent › High efficiency rating – Eurovent rating Class A › Reduced noise › Electronic expansion valve › Sequential control for Master/Slave function by default › Partial heat recovery optionally available › Total heat recovery optionally available

Operating limits, cooling only models:

Operating limits, heat pump models:

Standard equipment: › Main switch › Master/Slave Control › Direct start › Ventilator speed control (phase modulation) › Double setpoint value › Evaporator electric heater › Electronic expansion valve › Operating hours counter › Accumulative fault message

Out

side

tem

pera

ture

[o C]

45 cooling mode

35

25

15

5

-5

-15-15 -10 -5 0 5 10 15 20

Evaporator leaving water temperature [oC]

part-load operation

EWAQ G SS/SR – cooling only, standard efficiency EWAQ G XS/XR – cooling only, high efficiency

EWYQ G XS/XR – heat pump, high efficiency EWYQ G XS/XR - heat pump, high efficiency

Within this area the fans speed is increased for reduced noise version

Within this area the fans speed is increased for reduced noise version

Within this area the fans speed is increased for reduced noise version

-10°C reachable thanks to fan speed modulation provided as standard

-10°C reachable thanks to fan speed modulation provided as standard

Operation with glycol

Operation with glycol

Operation with glycol

43 45

45

-3-17

Page 19: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 19

EWAQ-G-SS Standard efficiency rating, standard noise level

ʯ Single refrigerant circuit (2 scroll compressors) with single evaporator

ʯ Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger ʯ MicroTech III controller with superior control logic and easy interface

Type of unit (rated power in accordance with EN14511) EWAQ -G-SS 075 085 100 110 120 140 155Price Lei 79.035,- 85.439,- 93.584,- 96.949,- 101.905,- 114.464,- 122.161,-Commissioning by DAIKIN service (net price) Lei 2.910,- 2.910,- 2.910,- 3.484,- 3.484,- 3.484,- 3.484,-Cooling capacity kW 74,7 84,2 96,7 107 117 139 154Power input kW 27,7 31,2 35,0 39,5 43,4 51,1 57,2Refrigerant circuit 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2EER 2,70 2,70 2,76 35,0 2,76 2,73 2,7ESEER 4,26 4,45 4,27 4,33 4,12 4,39 4,23Length mm 2.140 2.680 2.680 2.680 3.200 3.200 3.200Width mm 1.195 1.195 1.195 1.195 1.195 1.195 1.195Height mm 1.800 1.800 1.800 1.800 1.800 1.800 1.800Weight of unit / Operating weight kg 681/692 792/802 953/963 923/934 982/993 1.037/1.054 1.066/1.085Sound power / Sound pressure (at 1m) dB(A) 83/66 85/68 87/69 89/71 89/71 89/71 89/71Buffer tank volume / option (OP 134/135/136/137) liter 75 175 175 175 250 250 250

Air cooled chiller

Code Type of unit EWAQ -G-SS 075 085 100 110 120 140 155Mechanical20 Evaporator victaulic kit Lei

Standard 29 20mm evaporator insulation Lei01a Total heat recovery (including expansion card pol965) Lei 13.468,- 13.468,- 13.532,- 14.734,- 14.734,- 14.734,- 15.514,-03 Partial heat recovery Lei 4.873,- 4.873,- 4.873,- 4.967,- 4.967,- 5.815,- 5.815,-08 Brine version Lei 2.067,- 2.067,- 2.067,- 2.067,- 2.067,- 2.067,- 2.067,-126 Discharge and suction line shut-off valve Lei 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,-127 High and low pressure side manometers Lei 1.124,- 1.124,- 1.124,- 1.124,- 1.124,- 1.124,- 1.124,-138 Condenser coil guard Lei 1.872,- 2.067,- 2.067,- 2.067,- 2.245,- 2.245,- 2.245,-78 One centrifugal pump (low lift) Lei 9.498,- 10.117,- 10.117,- 10.117,- 10.566,- 11.241,- 11.241,-79 One centrifugal pump (high lift) Lei 11.465,- 12.364,- 12.364,- 12.364,- 12.818,- 12.818,- 12.818,-80 Two centrifugal pump (low lift) Lei 15.483,- 16.736,- 16.736,- 16.736,- 16.736,- 17.236,- 17.236,-81 Two centrifugal pump (high lift) Lei 18.189,- 19.636,- 19.636,- 19.636,- 20.010,- 20.010,- 20.010,-134 One centrifugal pump (low lift) + tank Lei 14.859,- 15.932,- 15.932,- 15.932,- 17.805,- 18.513,- 18.513,-135 One centrifugal pump (high lift) + tank Lei 16.831,- 18.179,- 18.179,- 18.179,- 20.087,- 20.087,- 20.087,-136 Two centrifugal pump (low lift) + tank Lei 23.723,- 24.807,- 24.807,- 24.807,- 25.108,- 25.481,- 25.481,-137 Two centrifugal pump (high lift) + tank Lei 25.676,- 27.108,- 27.108,- 27.108,- 27.484,- 27.484,- 27.484,-91 Double pressure relief valve with diverter Lei 4.123,- 4.123,- 4.123,- 4.123,- 4.123,- 4.123,- 4.123,-139 E-coating microchannel coils Lei 3.524,- 5.191,- 5.191,- 5.191,- 6.788,- 6.788,- 6.788,-115 Water filter Lei 2.163,- 2.163,- 2.163,- 2.163,- 2.163,- 2.163,- 2.163,-Electrical / Control04 Direct on line starter (dol) Lei

Standard

10 Double setpoint Lei57 Evaporator electric heater Lei60 Electronic expansion valve Lei67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 7.443,- 7.443,- 7.443,- 7.443,- 7.697,- 8.321,- 8.939,-

15a Control expansion pack including (under / over voltage control, setpoint reset, demand limit, alarm from external device, expansion card pol965)

Lei 1.692,- 1.692,- 1.692,- 1.692,- 1.692,- 1.692,- 1.692,-

17 Capacitors for power factor correction Lei 2.869,- 2.869,- 2.869,- 2.869,- 2.869,- 3.190,- 3.748,-58 Evaporator flow switch Lei 975,- 975,- 975,- 975,- 975,- 975,- 975,-95 Compressors circuit breakers Lei 1.318,- 1.372,- 1.423,- 1.423,- 1.423,- 1.617,- 1.796,-96 Fans circuit breakers Lei 748,- 748,- 748,- 748,- 748,- 748,- 748,-Installation75 Rubber anti vibration mounts Lei 1.703,- 1.703,- 1.703,- 1.703,- 1.703,- 1.703,- 1.703,-77 Spring anti vibration mounts Lei 5.341,- 5.341,- 5.341,- 5.341,- 5.341,- 5.341,- 5.341,-83 External tank without cabinet (500 l) Lei 13.167,- 13.167,- 13.167,- 13.167,- 13.167,- 13.167,- 13.167,-84 External tank without cabinet (1000 l) Lei 17.580,- 17.580,- 17.580,- 17.580,- 17.580,- 17.580,- 17.580,-87 External tank with cabinet (500 l) Lei 19.377,- 19.377,- 19.377,- 19.377,- 19.377,- 19.377,- 19.377,-88 External tank with cabinet (1000 l) Lei 24.828,- 24.828,- 24.828,- 24.828,- 24.828,- 24.828,- 24.828,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Optional accessories for chiller:

Page 20: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

20

EWAQ-G-SR

Standard efficiency rating, reduced noise level

Type of unit (rated power in accordance with EN14511) EWAQ-G-SR 075 085 100 110 120 140 155Price Lei 84.586,- 91.433,- 100.147,- 103.746,- 109.048,- 122.485,- 130.726,-Commissioning by DAIKIN service (net price) Lei 2.910,- 2.910,- 2.910,- 3.484,- 3.484,- 3.484,- 3.484,-Cooling capacity kW 69,3 78,9 91,0 99,7 109 130 143Power input kW 29,4 33,1 36,8 42,0 46,3 54,0 61,2Refrigerant circuit 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2EER 2,36 2,38 2,47 2,38 2,35 2,42 2,34ESEER 3,94 4,12 3,94 4,02 3,74 4,12 3,88Length mm 2.140 2.680 2.680 2.680 3.200 3.200 3.200Width mm 1.195 1.195 1.195 1.195 1.195 1.195 1.195Height mm 1.800 1.800 1.800 1.800 1.800 1.800 1.800Weight of unit / Operating weight kg 711/722 822/832 983/993 953/963 1.012/1.023 1.067/1.084 1.096/1.115Sound power / Sound pressure (at 1m) dB(A) 79/62 82/65 84/66 86/68 86/68 86/68 86/68Buffer tank volume / option (OP 134/135/136/137) liter 75 175 175 175 250 250 250

Optional accessories for chiller:

Code Type of unit EWAQ-G-SR 075 085 100 110 120 140 155Mechanical20 Evaporator victaulic kit Lei

Standard 29 20Mm evaporator insulation Lei

01A Total heat recovery (including expansion card pol965) Lei 13.468,- 13.468,- 13.532,- 14.734,- 14.734,- 14.734,- 15.514,-

03 Partial heat recovery Lei 4.873,- 4.873,- 4.873,- 4.967,- 4.967,- 5.815,- 5.815,-08 Brine version Lei 2.067,- 2.067,- 2.067,- 2.067,- 2.067,- 2.067,- 2.067,-126 Discharge and suction line shut-off valve Lei 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,-127 High and low pressure side manometers Lei 1.124,- 1.124,- 1.124,- 1.124,- 1.124,- 1.124,- 1.124,-138 Condenser coil guard Lei 1.872,- 2.067,- 2.067,- 2.067,- 2.245,- 2.245,- 2.245,-78 One centrifugal pump (low lift) Lei 9.498,- 10.117,- 10.117,- 10.117,- 10.566,- 11.241,- 11.241,-79 One centrifugal pump (high lift) Lei 11.465,- 12.364,- 12.364,- 12.364,- 12.818,- 12.818,- 12.818,-80 Two centrifugal pump (low lift) Lei 15.483,- 16.736,- 16.736,- 16.736,- 16.736,- 17.236,- 17.236,-81 Two centrifugal pump (high lift) Lei 18.189,- 19.636,- 19.636,- 19.636,- 20.010,- 20.010,- 20.010,-134 One centrifugal pump (low lift) + tank Lei 14.859,- 15.932,- 15.932,- 15.932,- 17.805,- 18.513,- 18.513,-135 One centrifugal pump (high lift) + tank Lei 16.831,- 18.179,- 18.179,- 18.179,- 20.087,- 20.087,- 20.087,-136 Two centrifugal pump (low lift) + tank Lei 23.723,- 24.807,- 24.807,- 24.807,- 25.108,- 25.481,- 25.481,-137 Two centrifugal pump (high lift) + tank Lei 25.676,- 27.108,- 27.108,- 27.108,- 27.484,- 27.484,- 27.484,-91 Double pressure relief valve with diverter Lei 4.123,- 4.123,- 4.123,- 4.123,- 4.123,- 4.123,- 4.123,-139 E-coating microchannel coils Lei 3.524,- 5.191,- 5.191,- 5.191,- 6.788,- 6.788,- 6.788,-115 Water filter Lei 2.163,- 2.163,- 2.163,- 2.163,- 2.163,- 2.163,- 2.163,-Electrical / control04 Direct on line starter (dol) Lei

Standard

10 Double setpoint Lei57 Evaporator electric heater Lei60 Electronic expansion valve Lei

67 Ambient outside temperature sensor and setpoint reset Lei

68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 7.443,- 7.443,- 7.443,- 7.443,- 7.697,- 8.321,- 8.939,-

15AControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.692,- 1.692,- 1.692,- 1.692,- 1.692,- 1.692,- 1.692,-

17 Capacitors for power factor correction Lei 2.869,- 2.869,- 2.869,- 2.869,- 2.869,- 3.190,- 3.748,-58 Evaporator flow switch Lei 975,- 975,- 975,- 975,- 975,- 975,- 975,-95 Compressors circuit breakers Lei 1.318,- 1.372,- 1.423,- 1.423,- 1.423,- 1.617,- 1.796,-96 Fans circuit breakers Lei 748,- 748,- 748,- 748,- 748,- 748,- 748,-Installation75 Rubber anti vibration mounts Lei 1.703,- 1.703,- 1.703,- 1.703,- 1.703,- 1.703,- 1.703,-77 Spring anti vibration mounts Lei 5.341,- 5.341,- 5.341,- 5.341,- 5.341,- 5.341,- 5.341,-83 External tank without cabinet (500 l) Lei 13.167,- 13.167,- 13.167,- 13.167,- 13.167,- 13.167,- 13.167,-84 External tank without cabinet (1000 l) Lei 17.580,- 17.580,- 17.580,- 17.580,- 17.580,- 17.580,- 17.580,-87 External tank with cabinet (500 l) Lei 19.377,- 19.377,- 19.377,- 19.377,- 19.377,- 19.377,- 19.377,-88 External tank with cabinet (1000 l) Lei 24.828,- 24.828,- 24.828,- 24.828,- 24.828,- 24.828,- 24.828,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Air cooled chiller

Page 21: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 21

EWAQ-G-XSHigh efficiency rating, standard noise level

ʯ Single refrigerant circuit (2 scroll compressors) with single evaporator ʯ Reduced amount of refrigerant tanks to micro channel heat exchanger technology

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger ʯ MicroTech III controller with superior control logic and easy interface

Type of unit (rated power in accordance with EN14511) EWAQ-G-XS 080 090 105 115 130 150Price Lei 98.052,- 105.344,- 114.444,- 120.558,- 130.482,- 139.945,-Commissioning by DAIKIN service (net price) Lei 2.910,- 2.910,- 2.910,- 3.484,- 3.484,- 3.484,-Cooling capacity kW 79,8 90,3 105 117 131 149Power input kW 25,8 29,0 33,8 37,7 42,3 48,1Refrigerant circuit 1 1 1 1 1 1Compressors 2 2 2 2 2 2EER 3,10 3,11 3,12 3,10 3,10 3,10ESEER 4,2 4,3 4,28 4,34 4,22 4,36Length mm 2.680 3.200 3.200 3.200 3.800 3.800Width mm 1.195 1.195 1.195 1.195 1.195 1.195Height mm 1.800 1.800 1.800 1.800 1.820 1.820Weight of unit / Operating weight kg 734/744 850/860 1.020/1.035 991/1.007 1.086/1.102 1.123/1.144Sound power / Sound pressure (at 1m) dB(A) 84/66 85/68 87/69 89/71 89/71 89/71Buffer tank volume / option (OP 134/135/136/137) liter 75 175 175 175 250 250

Optional accessories for chiller:

Code Type of unit EWAQ-G-XS 080 090 105 115 130 150Mechanical20 Evaporator victaulic kit Lei

Standard 29 20Mm evaporator insulation Lei01a Total heat recovery (including expansion card pol965) Lei 13.468,- 13.468,- 13.532,- 14.734,- 14.734,- 14.734,-03 Partial heat recovery Lei 4.873,- 4.873,- 4.873,- 4.967,- 4.967,- 5.815,-08 Brine version Lei 2.067,- 2.067,- 2.067,- 2.067,- 2.067,- 2.067,-126 Discharge and suction line shut-off valve Lei 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,-127 High and low pressure side manometers Lei 1.124,- 1.124,- 1.124,- 1.124,- 1.124,- 1.124,-138 Condenser coil guard Lei 2.067,- 2.245,- 2.245,- 2.245,- 2.815,- 2.815,-78 One centrifugal pump (low lift) Lei 10.117,- 10.566,- 10.566,- 10.566,- 11.689,- 11.689,-79 One centrifugal pump (high lift) Lei 12.364,- 12.818,- 12.818,- 12.818,- 13.642,- 13.642,-80 Two centrifugal pump (low lift) Lei 16.736,- 16.736,- 16.736,- 16.736,- 17.915,- 17.915,-81 Two centrifugal pump (high lift) Lei 19.636,- 20.010,- 20.010,- 20.010,- 20.580,- 20.580,-134 One centrifugal pump (low lift) + tank Lei 15.932,- 17.805,- 17.805,- 17.805,- 18.927,- 18.927,-135 One centrifugal pump (high lift) + tank Lei 18.179,- 20.087,- 20.087,- 20.087,- 20.908,- 20.908,-136 Two centrifugal pump (low lift) + tank Lei 24.807,- 25.108,- 25.108,- 25.108,- 25.976,- 25.976,-137 Two centrifugal pump (high lift) + tank Lei 27.108,- 27.484,- 27.484,- 27.484,- 27.923,- 28.296,-91 Double pressure relief valve with diverter Lei 4.123,- 4.123,- 4.123,- 4.123,- 4.123,- 4.123,-139 E-coating microchannel coils Lei 5.191,- 6.788,- 6.788,- 6.788,- 8.619,- 8.619,-115 Water filter Lei 2.163,- 2.163,- 2.163,- 2.163,- 2.163,- 2.163,-Electrical / Control04 Direct on line starter (dol) Lei

Standard

10 Double setpoint Lei57 Evaporator electric heater Lei60 Electronic expansion valve Lei

67 Ambient outside temperature sensor and setpoint reset Lei

68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 7.443,- 7.443,- 7.443,- 7.443,- 7.697,- 8.321,-

15a Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.692,- 1.692,- 1.692,- 1.692,- 1.692,- 1.692,-

17 Capacitors for power factor correction Lei 2.869,- 2.869,- 2.869,- 2.869,- 2.869,- 3.190,-58 Evaporator flow switch Lei 975,- 975,- 975,- 975,- 975,- 975,-95 Compressors circuit breakers Lei 1.318,- 1.372,- 1.423,- 1.423,- 1.423,- 1.617,-96 Fans circuit breakers Lei 748,- 748,- 748,- 748,- 748,- 748,-Installation75 Rubber anti vibration mounts Lei 1.703,- 1.703,- 1.703,- 1.703,- 1.703,- 1.703,-77 Spring anti vibration mounts Lei 5.341,- 5.341,- 5.341,- 5.341,- 5.341,- 5.341,-83 External tank without cabinet (500 l) Lei 13.167,- 13.167,- 13.167,- 13.167,- 13.167,- 13.167,-84 External tank without cabinet (1000 l) Lei 17.580,- 17.580,- 17.580,- 17.580,- 17.580,- 17.580,-87 External tank with cabinet (500 l) Lei 19.377,- 19.377,- 19.377,- 19.377,- 19.377,- 19.377,-88 External tank with cabinet (1000 l) Lei 24.828,- 24.828,- 24.828,- 24.828,- 24.828,- 24.828,-Communication cards / Accessories

EKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Air cooled chiller

Page 22: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

22

EWAQ-G-XR

High efficiency rating, reduced noise level

Type of unit (rated power in accordance with EN14511) EWAQ-G-XR 080 090 105 115 130 150Price Lei 103.597,- 111.339,- 121.008,- 127.357,- 137.624,- 147.966,-Commissioning by DAIKIN service (net price) Lei 2.910,- 2.910,- 2.910,- 3.484,- 3.484,- 3.484,-Cooling capacity kW 76,0 86,0 100 110 125 141Power input kW 26,4 29,9 34,7 39,0 43,3 49,8Refrigerant circuit 1 1 1 1 1 1Compressors 2 2 2 2 2 2EER 2,88 2,88 2,89 2,83 2,88 2,83ESEER 4,18 4,29 4,27 4,21 4,31 4,33Length mm 2.860 3.200 3.200 3.200 3.800 3.800Width mm 1.195 1.195 1.195 1.195 1.195 1.195Height mm 1.800 1.800 1.800 1.800 1.820 1.820Weight of unit / Operating weight kg 764/774 880/890 1.050/1.065 1.021/1.037 1.116/1.132 1.153/1.174Sound power / Sound pressure (at 1m) dB(A) 80/62 82/65 84/66 86/68 86/67 86/67Buffer tank volume / option (OP 134/135/136/137) liter 75 175 175 175 250 250

Optional accessories for chiller:

Code Type of unit EWAQ-G-XR 080 090 105 115 130 150Mechanical20 Evaporator victaulic kit Lei

Standard 29 20mm evaporator insulation Lei

01a Total heat recovery (including expansion card pol965) Lei 13.468,- 13.468,- 13.532,- 14.734,- 14.734,- 14.734,-

03 Partial heat recovery Lei 4.873,- 4.873,- 4.873,- 4.967,- 4.967,- 5.815,-08 Brine version Lei 2.067,- 2.067,- 2.067,- 2.067,- 2.067,- 2.067,-126 Discharge and suction line shut-off valve Lei 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,-127 High and low pressure side manometers Lei 1.124,- 1.124,- 1.124,- 1.124,- 1.124,- 1.124,-138 Condenser coil guard Lei 2.067,- 2.245,- 2.245,- 2.245,- 2.815,- 2.815,-78 One centrifugal pump (low lift) Lei 10.117,- 10.566,- 10.566,- 10.566,- 11.689,- 11.689,-79 One centrifugal pump (high lift) Lei 12.364,- 12.818,- 12.818,- 12.818,- 13.642,- 13.642,-80 Two centrifugal pump (low lift) Lei 16.736,- 16.736,- 16.736,- 16.736,- 17.915,- 17.915,-81 Two centrifugal pump (high lift) Lei 19.636,- 20.010,- 20.010,- 20.010,- 20.580,- 20.580,-134 One centrifugal pump (low lift) + tank Lei 15.932,- 17.805,- 17.805,- 17.805,- 18.927,- 18.927,-135 One centrifugal pump (high lift) + tank Lei 18.179,- 20.087,- 20.087,- 20.087,- 20.908,- 20.908,-136 Two centrifugal pump (low lift) + tank Lei 24.807,- 25.108,- 25.108,- 25.108,- 25.976,- 25.976,-137 Two centrifugal pump (high lift) + tank Lei 27.108,- 27.484,- 27.484,- 27.484,- 27.923,- 28.296,-91 Double pressure relief valve with diverter Lei 4.123,- 4.123,- 4.123,- 4.123,- 4.123,- 4.123,-139 E-coating microchannel coils Lei 5.191,- 6.788,- 6.788,- 6.788,- 8.619,- 8.619,-115 Water filter Lei 2.163,- 2.163,- 2.163,- 2.163,- 2.163,- 2.163,-Electrical / Control04 Direct on line starter (dol) Lei

Standard

10 Double setpoint Lei57 Evaporator electric heater Lei60 Electronic expansion valve Lei

67 Ambient outside temperature sensor and setpoint reset Lei

68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 7.443,- 7.443,- 7.443,- 7.443,- 7.697,- 8.321,-

15a Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.692,- 1.692,- 1.692,- 1.692,- 1.692,- 1.692,-

17 Capacitors for power factor correction Lei 2.869,- 2.869,- 2.869,- 2.869,- 2.869,- 3.190,-58 Evaporator flow switch Lei 975,- 975,- 975,- 975,- 975,- 975,-95 Compressors circuit breakers Lei 1.318,- 1.372,- 1.423,- 1.423,- 1.423,- 1.617,-96 Fans circuit breakers Lei 748,- 748,- 748,- 748,- 748,- 748,-Installation75 Rubber anti vibration mounts Lei 1.703,- 1.703,- 1.703,- 1.703,- 1.703,- 1.703,-77 Spring anti vibration mounts Lei 5.341,- 5.341,- 5.341,- 5.341,- 5.341,- 5.341,-83 External tank without cabinet (500 l) Lei 13.167,- 13.167,- 13.167,- 13.167,- 13.167,- 13.167,-84 External tank without cabinet (1000 l) Lei 17.580,- 17.580,- 17.580,- 17.580,- 17.580,- 17.580,-87 External tank with cabinet (500 l) Lei 19.377,- 19.377,- 19.377,- 19.377,- 19.377,- 19.377,-88 External tank with cabinet (1000 l) Lei 24.828,- 24.828,- 24.828,- 24.828,- 24.828,- 24.828,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Air cooled chiller

Page 23: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 23

EWYQ-G-XS

High efficiency rating, standard noise level

ʯ Compact design ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger ʯ MicroTech III controller with superior control logic and easy interface

Type of unit (rated power in accordance with EN14511) EWYQ-G-XS 075 085 100 110 120 140 160Price Lei 98.186,- 107.829,- 119.710,- 130.577,- 137.754,- 151.576,- 163.023,-Commissioning by DAIKIN service (net price) Lei 2.910,- 2.910,- 2.910,- 3.484,- 3.484,- 3.484,- 3.484,-Cooling capacity kW 77,8 88,1 101 117 127 147 165Power input (cooling) kW 27,0 31,5 36,0 39,5 44,7 50,2 57,8Heating capacity kW 82,2 91,2 110 127 138 156 170Power input (heating) kW 26,0 29,0 34,0 39,0 43,0 50,0 54,0Refrigerant circuit 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2EER 2,88 2,80 2,81 2,97 2,84 2,92 2,85ESEER 3,9 3,94 3,97 4,03 3,92 3,96 3,96COP 3,14 3,12 3,24 3,25 3,2 3,11 3,13Length x Width x Height mm 2.826 x 1.195 x 1.800 3.426 x 1.195 x 1.800 4.026 x 1.195 x 1.800Weight of unit / Operating weight kg 850/858 912/921 1.077/1.088 1.183/1.194 1.213/1.224 1.333/1.344 1.394/1.411Space heating Average

climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 131 129 142 140 142 138 140

SCOP 3,35 3,31 3,62 3,58 3,63 3,53 3,58Sound power / Sound pressure (at 1m) dB(A) 84/ 66 85/ 68 87/ 70 89/71 89/71 89/71 89/71Buffer tank volume / option (OP 134/135/136/137) liter 75 175 175 175 250 250 250

Optional accessories for chiller:Code Type of unit EWYQ-G-XS 075 085 100 110 120 140 160Mechanical20 Evaporator victaulic kit Lei

Standard 29 20mm evaporator insulation Lei49 Alucoat fins coil Lei03 Partial heat recovery Lei 4.920,- 4.920,- 4.920,- 5.016,- 5.016,- 5.873,- 5.873,-08 Brine version Lei 2.087,- 2.087,- 2.087,- 2.087,- 2.087,- 2.087,- 2.087,-126 Discharge and suction line shut-off valve Lei 3.483,- 3.483,- 3.483,- 3.483,- 3.483,- 3.483,- 3.483,-127 High and low pressure side manometers Lei 1.135,- 1.135,- 1.135,- 1.135,- 1.135,- 1.135,- 1.135,-138 Condenser coil guard Lei 2.087,- 2.087,- 2.087,- 2.269,- 2.269,- 2.843,- 2.843,-78 One centrifugal pump (low lift) Lei 10.217,- 10.217,- 10.217,- 10.671,- 10.671,- 11.806,- 11.806,-79 One centrifugal pump (high lift) Lei 12.486,- 12.486,- 12.486,- 12.943,- 12.943,- 13.776,- 13.776,-80 Two centrifugal pump (low lift) Lei 16.901,- 16.901,- 16.901,- 16.901,- 16.901,- 18.091,- 18.091,-81 Two centrifugal pump (high lift) Lei 19.830,- 19.830,- 19.830,- 20.207,- 20.207,- 20.783,- 20.783,-134 One centrifugal pump (low lift) + tank Lei 16.090,- 16.090,- 16.090,- 17.980,- 17.980,- 19.114,- 19.114,-135 One centrifugal pump (high lift) + tank Lei 18.357,- 18.357,- 18.357,- 20.283,- 20.283,- 21.115,- 21.115,-136 Two centrifugal pump (low lift) + tank Lei 25.051,- 25.051,- 25.051,- 25.355,- 25.355,- 26.231,- 26.231,-137 Two centrifugal pump (high lift) + tank Lei 27.375,- 27.375,- 27.375,- 27.754,- 27.754,- 28.576,- 28.576,-91 Double pressure relief valve with diverter Lei 4.164,- 4.164,- 4.164,- 4.164,- 4.164,- 4.164,- 4.164,-115 Water filter Lei 2.183,- 2.183,- 2.183,- 2.183,- 2.183,- 2.183,- 2.183,-114 Nordic kit Lei 4.164,- 4.164,- 4.164,- 4.920,- 4.920,- 5.675,- 5.675,-Electrical / Control04 Direct on line starter (dol) Lei

Standard

10 Double setpoint Lei57 Evaporator electric heater Lei60 Electronic expansion valve Lei67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 7.515,- 7.515,- 7.515,- 7.515,- 7.773,- 8.402,- 9.027,-

15a Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.709,- 1.709,- 1.709,- 1.709,- 1.709,- 1.709,- 1.709,-

17 Capacitors for power factor correction Lei 2.898,- 2.898,- 2.898,- 2.898,- 2.898,- 3.222,- 3.786,-58 Evaporator flow switch Lei 984,- 984,- 984,- 984,- 984,- 984,- 984,-95 Compressors circuit breakers Lei 1.331,- 1.386,- 1.437,- 1.437,- 1.437,- 1.633,- 1.814,-96 Fans circuit breakers Lei 757,- 757,- 757,- 757,- 757,- 757,- 757,-Installation75 Rubber anti vibration mounts Lei 1.719,- 1.719,- 1.719,- 1.719,- 1.719,- 1.719,- 1.719,-77 Spring anti vibration mounts Lei 5.394,- 5.394,- 5.394,- 5.394,- 5.394,- 5.394,- 5.394,-83 External tank without cabinet (500 l) Lei 13.297,- 13.297,- 13.297,- 13.297,- 13.297,- 13.297,- 13.297,-84 External tank without cabinet (1000 l) Lei 17.754,- 17.754,- 17.754,- 17.754,- 17.754,- 17.754,- 17.754,-87 External tank with cabinet (500 l) Lei 19.568,- 19.568,- 19.568,- 19.568,- 19.568,- 19.568,- 19.568,-88 External tank with cabinet (1000 l) Lei 25.072,- 25.072,- 25.072,- 25.072,- 25.072,- 25.072,- 25.072,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Air cooled heat pump

Page 24: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

24

EWYQ-G-XR

High efficiency rating, reduced noise level

Type of unit (rated power in accordance with EN14511) EWYQ-G-XR 075 085 100 110 120 140 160Price Lei 103.786,- 113.884,- 126.338,- 137.443,- 144.968,- 159.673,- 171.125,-Commissioning by DAIKIN service (net price) Lei 2.910,- 2.910,- 2.910,- 3.484,- 3.484,- 3.484,- 3.484,-Cooling capacity kW 75,2 84,5 95 111 120 139 155Power input kW 27,7 32,7 38,6 41,5 47,4 52,8 61,5Heating capacity kW 82,2 91,2 110 127 138 156 170Power input (heating) kW 26 29 34 39 43 50 54Refrigerant circuit 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2EER 2,71 2,59 2,46 2,68 2,52 2,64 2,51ESEER 3,85 3,9 3,79 3,92 3,76 3,86 3,79COP 3,14 3,12 3,24 3,25 3,2 3,11 3,13Length x Width x Height mm 2.826 x 1.195 x 1.800 3.426 x 1.195 x 1.800 4.026 x 1.195 x 1.800Weight of unit / Operating weight kg 880/888 942/951 1.107/1.118 1.233/1.224 1.243/1.254 1.363/1.374 1.424/1.441Space heating Average climate

wateroutlet 35°C

ηs (Seasonal space heating efficiency

% 131 129 142 140 142 138 140

SCOP 3,35 3,31 3,62 3,58 3,63 3,53 3,58Sound power / Sound pressure (at 1m) dB(A) 80/62 82/65 84/66 86/68 86/68 86/67 86/67Buffer tank volume / option (OP 134/135/136/137) liter 75 175 175 175 250 250 250

Optional accessories for chiller:Code Type of unit EWYQ-G-XR 075 085 100 110 120 140 160Mechanical20 Evaporator victaulic kit Lei

Standard 29 20mm evaporator insulation Lei49 Alucoat fins coil Lei03 Partial heat recovery Lei 4.920,- 4.920,- 4.920,- 5.016,- 5.016,- 5.873,- 5.873,-08 Brine version Lei 2.087,- 2.087,- 2.087,- 2.087,- 2.087,- 2.087,- 2.087,-126 Discharge and suction line shut-off valve Lei 3.483,- 3.483,- 3.483,- 3.483,- 3.483,- 3.483,- 3.483,-127 High and low pressure side manometers Lei 1.135,- 1.135,- 1.135,- 1.135,- 1.135,- 1.135,- 1.135,-138 Condenser coil guard Lei 2.087,- 2.087,- 2.087,- 2.269,- 2.269,- 2.843,- 2.843,-78 One centrifugal pump (low lift) Lei 10.217,- 10.217,- 10.217,- 10.671,- 10.671,- 11.806,- 11.806,-79 One centrifugal pump (high lift) Lei 12.486,- 12.486,- 12.486,- 12.943,- 12.943,- 13.776,- 13.776,-80 Two centrifugal pump (low lift) Lei 16.901,- 16.901,- 16.901,- 16.901,- 16.901,- 18.091,- 18.091,-81 Two centrifugal pump (high lift) Lei 19.830,- 19.830,- 19.830,- 20.207,- 20.207,- 20.783,- 20.783,-134 One centrifugal pump (low lift) + tank Lei 16.090,- 16.090,- 16.090,- 17.980,- 17.980,- 19.114,- 19.114,-135 One centrifugal pump (high lift) + tank Lei 18.357,- 18.357,- 18.357,- 20.283,- 20.283,- 21.115,- 21.115,-136 Two centrifugal pump (low lift) + tank Lei 25.051,- 25.051,- 25.051,- 25.355,- 25.355,- 26.231,- 26.231,-137 Two centrifugal pump (high lift) + tank Lei 27.375,- 27.375,- 27.375,- 27.754,- 27.754,- 28.576,- 28.576,-91 Double pressure relief valve with diverter Lei 4.164,- 4.164,- 4.164,- 4.164,- 4.164,- 4.164,- 4.164,-115 Water filter Lei 2.183,- 2.183,- 2.183,- 2.183,- 2.183,- 2.183,- 2.183,-114 Nordic kit Lei 4.164,- 4.164,- 4.164,- 4.920,- 4.920,- 5.675,- 5.675,-Electrical / Control04 Direct on line starter (dol) Lei

Standard

10 Double setpoint Lei57 Evaporator electric heater Lei60 Electronic expansion valve Lei67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 7.515,- 7.515,- 7.515,- 7.515,- 7.773,- 8.402,- 9.027,-

15a Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.709,- 1.709,- 1.709,- 1.709,- 1.709,- 1.709,- 1.709,-

17 Capacitors for power factor correction Lei 2.898,- 2.898,- 2.898,- 2.898,- 2.898,- 3.222,- 3.786,-58 Evaporator flow switch Lei 984,- 984,- 984,- 984,- 984,- 984,- 984,-95 Compressors circuit breakers Lei 1.331,- 1.386,- 1.437,- 1.437,- 1.437,- 1.633,- 1.814,-96 Fans circuit breakers Lei 757,- 757,- 757,- 757,- 757,- 757,- 757,-Installation75 Rubber anti vibration mounts Lei 1.719,- 1.719,- 1.719,- 1.719,- 1.719,- 1.719,- 1.719,-77 Spring anti vibration mounts Lei 5.394,- 5.394,- 5.394,- 5.394,- 5.394,- 5.394,- 5.394,-83 External tank without cabinet (500 l) Lei 13.297,- 13.297,- 13.297,- 13.297,- 13.297,- 13.297,- 13.297,-84 External tank without cabinet (1000 l) Lei 17.754,- 17.754,- 17.754,- 17.754,- 17.754,- 17.754,- 17.754,-87 External tank with cabinet (500 l) Lei 19.568,- 19.568,- 19.568,- 19.568,- 19.568,- 19.568,- 19.568,-88 External tank with cabinet (1000 l) Lei 25.072,- 25.072,- 25.072,- 25.072,- 25.072,- 25.072,- 25.072,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Air cooled heat pump

Page 25: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 25

ARGUE CARDS

EWAT-B- Multi scroll Air cooled chillerwith R-32 refrigerant

Single V

Modular V

EWAT-B- at a glance

• Wide capacity range: 80 – 700 kW

• Silver and Gold efficiency versions

• 3 sound configurations

• Full compatibility with Daikin on Site

• New Hydronic Kit configurations

(single and twin pump, inertial tank, VFD)

• Single and dual circuit version overlapping between 150 kW and 350 kW

• Extensive option lists

• Fan speed modulation option (VFD)

Page 26: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

26

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-SS 85 115 135 155 175 195 205Price Lei 83.824,- 99.500,- 111.266,- 139.420,- 132.292,- 161.906,- 224.083,-Commissioning by DAIKIN service (net price) Lei On Request On Request On Request On Request On Request On Request On RequestCooling capacity kW 81 109 131 158 175 191 210Power input kW 31,8 38,5 49,8 61,8 67,7 69,4 79,8Refrigerant circuit 1 1 1 2 1 2 2Compressors 2 2 2 4 2 4 4EER 2,55 2,82 2,64 2,55 2,58 2,75 2,63ESEER(+opt FANMOD)(2) 3,96 4,03 3,86 3,83 4,09 4 3,94Length x Width x Height mm 2.120x1.204x1.801 2.660x1.204x1.801 2.660x1.204x1.801 3.570x1.204x1.822 3.180x1.204x1.801 4.170x1.204x1.822 4.170x1.204x1.822Weight of unit / Operating weight kg 681/686 767/773 811/821 1.007/1.014 984/996 1.166/1.177 1.158/1.169Sound power / Sound pressure (at 1m) dB(A) 85/67 88/71 90/72 88/70 92/74 90/71 91/72Buffer tank volume / option (OP 134/135/136/137) liter 50 145 145 190 190 250 250

Optional accessories for chiller:Code Type of unit EWAT -B-SS 85 115 135 155 175 195 205Mechanical01 Total heat recovery Lei

n/a 19.280,- 24.513,- 29.934,- 29.934,- 34.931,- 38.892,-

03A Partial heat recovery with control Lei 7.802,- 10.418,- 14.378,- 10.418,- 14.378,- 14.378,-08 Brine version Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-20 Evaporator victaulic kit Lei Standard21 Evaporator flange kit Lei 848,- 848,- 848,- 848,- 848,- 848,- 848,-29 20mm evaporator insulation Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-78 One centrifugal pump (low lift) Lei 13.270,- 13.860,- 13.860,- 14.731,- 14.731,- 15.321,- 15.321,-79 One centrifugal pump (high lift) Lei 16.193,- 16.806,- 16.806,- 16.806,- 16.806,- 17.866,- 17.866,-80 Two centrifugal pump (low lift) Lei 21.920,- 21.920,- 21.920,- 22.579,- 22.579,- 23.476,- 23.476,-81 Two centrifugal pump (high lift) Lei 25.715,- 26.234,- 26.234,- 26.234,- 26.234,- 26.940,- 26.940,-91 Double pressure relief valve with diverter Lei 5.421,- 5.421,- 5.421,- 8.062,- 5.421,- 8.062,- 8.062,-115 Water filter Lei 1.509,- 1.509,- 1.509,- 1.815,- 1.509,- 1.815,- 1.815,-121 Refrigerant leak detection Lei 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,-126 Discharge and suction line shut-off valve Lei 4.525,- 4.525,- 4.525,- 9.052,- 4.525,- 9.052,- 9.052,-127 High and low pressure side manometers Lei 1.485,- 1.485,- 1.485,- 2.970,- 1.485,- 2.970,- 2.970,-134 One centrifugal pump (low lift) + tank Lei 20.859,- 23.334,- 23.334,- 24.255,- 24.255,- 24.796,- 24.796,-135 One centrifugal pump (high lift) + tank Lei 23.806,- 26.327,- 26.327,- 26.327,- 26.327,- 27.389,- 27.389,-136 Two centrifugal pump (low lift) + tank Lei 32.480,- 32.905,- 32.905,- 33.376,- 33.376,- 34.012,- 34.012,-137 Two centrifugal pump (high lift) + tank Lei 35.496,- 36.015,- 36.015,- 36.015,- 36.015,- 37.052,- 37.052,-139 E-coating microchannel coils Lei 4.525,- 6.788,- 6.788,- 9.052,- 9.052,- 11.313,- 11.313,-140 Unit guards (to cover unit access) Lei 2.593,- 2.829,- 2.829,- 3.065,- 3.065,- 3.299,- 3.299,-Electrical / Control04 Direct on line starter (dol) Lei Standard 06 Soft starter Lei 10.583,- 12.540,- 14.024,- 17.584,- 16.687,- 20.412,- 22.415,-10 Double setpoint Lei Standard 15 Under / over voltage control Lei 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,-16 Energy meter Lei n/a 7.189,- n/a 7.189,- 7.189,-17B Capacitors for power factor correction (single-v) Lei 2.829,- 3.008,- 3.186,- 5.657,- 3.809,- 5.836,- 6.015,-57 Evaporator electric heater Lei Standard 58 Evaporator flow switch Lei 1.698,- 1.698,- 1.698,- 1.698,- 1.698,- 1.698,- 1.698,-

EWAT-B-SSStandard efficiency rating, standard noise level ʯ R-32 refrigerant with low GWP. Reduced amount of refrigerant tanks to micro

channel heat exchanger technology ʯ One or two independent refrigerant circuits (2 or 4 scroll compressors) with

single evaporator ʯ Wide capacity range: 80 - 700 kW (“Single V” layout up to 210 kW, “Multi V”

layout up to 700 kW) ʯ Two efficiency level and 3 sound configurations Free cooling migration

options available for Multi V models(1)

ʯ Partial and total heat recovery option available ʯ Stainless steel plate heat exchanger optimized for R-32 refrigerant operation ʯ MicroTech III controller with superior control logic and easy interface

NEW

Page 27: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 27

Air cooled chiller

Installation75 Rubber anti vibration mounts Lei 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,-77 Spring anti vibration mounts Lei 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,-83 External tank without cabinet (500 l) Lei 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,-84 External tank without cabinet (1000 l) Lei 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,-87 External tank with cabinet (500 l) Lei 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,-88 External tank with cabinet (1000 l) Lei 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- (1) Check the databook for Multi V models; (2) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Optional accessories for chiller:

Code Type of unit EWAT -B-SS 85 115 135 155 175 195 20560 Electronic expansion valve Lei

Standard67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei70 Alarm from external device Lei95 Compressors circuit breakers Lei 1.744,- 1.957,- 2.169,- 3.488,- 2.663,- 3.701,- 3.912,-96 Fans circuit breakers Lei 1.013,- 1.013,- 1.013,- 1.013,- 1.013,- 1.013,- 1.013,-97 Main switch interlock door Lei

Standard 99 Fans speed regulation (+ fan silent mode) Lei120e Inverter kit for 1 centr pump low lift Lei 4.478,- 4.855,- 4.855,- 5.610,- 5.610,- 5.610,- 5.610,-120f Inverter kit for 1 centr pump high lift Lei 5.610,- 5.610,- 5.610,- 5.610,- 5.610,- 5.610,- 5.610,-128 Master/slave Lei Standard142A High ambient kit Lei 3.394,- 4.289,- 4.289,- 5.186,- 5.186,- 6.081,- 6.081,-143 Variable primary flow Lei 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,-144 Diff pressure transd (shipped loose) Lei 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,-155 Daikin on site modem (with antenna) Lei 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,-160 100 pa esp fans Lei 1.980,- 2.876,- 2.876,- 3.770,- 3.770,- 4.667,- 4.667,-

Page 28: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

28

EWAT-B-SLStandard efficiency rating, low noise level

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-SL 85 115 135 155 175 195 205Price Lei 85.507,- 101.502,- 113.493,- 142.226,- 134.949,- 165.160,- 228.584,-Commissioning by DAIKIN service (net price) Lei On Request On Request On Request On Request On Request On Request On RequestCooling capacity kW 81 109 131 158 175 191 210Power input kW 31,8 38,5 49,8 61,8 67,7 69,4 79,8Refrigerant circuit 1 1 1 2 1 2 2Compressors 2 2 2 4 2 4 4EER 2,55 2,82 2,64 2,55 2,58 2,75 2,63ESEER(+opt FANMOD)(1) 3,96 4,03 3,86 3,83 4,09 4 3,94Length x Width x Height mm 2.120x1.204x1.801 2.660x1.204x1.801 2.660x1.204x1.801 3.570x1.204x1.822 3.180x1.204x1.801 4.170x1.204x1.822 4.170x1.204x1.822Weight of unit / Operating weight kg 691/696 777/783 820/830 1.028/1.035 994/1.006 1.087/1.198 1.179/1.190Sound power / Sound pressure (at 1m) dB(A) 84/66 86/69 87/69 87/68 89/71 88/70 89/70Buffer tank volume / option (OP 134/135/136/137) liter 50 145 145 190 190 250 250

Optional accessories for chiller:Code Type of unit EWAT -B-SL 85 115 135 155 175 195 205Mechanical01 Total heat recovery Lei

n/a 19.280,- 24.513,- 29.934,- 29.934,- 34.931,- 38.892,-

03A Partial heat recovery with control Lei 7.802,- 10.418,- 14.378,- 10.418,- 14.378,- 14.378,-08 Brine version Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-20 Evaporator victaulic kit Lei Standard21 Evaporator flange kit Lei 848,- 848,- 848,- 848,- 848,- 848,- 848,-29 20mm evaporator insulation Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-78 One centrifugal pump (low lift) Lei 13.270,- 13.860,- 13.860,- 14.731,- 14.731,- 15.321,- 15.321,-79 One centrifugal pump (high lift) Lei 16.193,- 16.806,- 16.806,- 16.806,- 16.806,- 17.866,- 17.866,-80 Two centrifugal pump (low lift) Lei 21.920,- 21.920,- 21.920,- 22.579,- 22.579,- 23.476,- 23.476,-81 Two centrifugal pump (high lift) Lei 25.715,- 26.234,- 26.234,- 26.234,- 26.234,- 26.940,- 26.940,-91 Double pressure relief valve with diverter Lei 5.421,- 5.421,- 5.421,- 8.062,- 5.421,- 8.062,- 8.062,-115 Water filter Lei 1.509,- 1.509,- 1.509,- 1.815,- 1.509,- 1.815,- 1.815,-121 Refrigerant leak detection Lei 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,-126 Discharge and suction line shut-off valve Lei 4.525,- 4.525,- 4.525,- 9.052,- 4.525,- 9.052,- 9.052,-127 High and low pressure side manometers Lei 1.485,- 1.485,- 1.485,- 2.970,- 1.485,- 2.970,- 2.970,-134 One centrifugal pump (low lift) + tank Lei 20.859,- 23.334,- 23.334,- 24.255,- 24.255,- 24.796,- 24.796,-135 One centrifugal pump (high lift) + tank Lei 23.806,- 26.327,- 26.327,- 26.327,- 26.327,- 27.389,- 27.389,-136 Two centrifugal pump (low lift) + tank Lei 32.480,- 32.905,- 32.905,- 33.376,- 33.376,- 34.012,- 34.012,-137 Two centrifugal pump (high lift) + tank Lei 35.496,- 36.015,- 36.015,- 36.015,- 36.015,- 37.052,- 37.052,-139 E-coating microchannel coils Lei 4.525,- 6.788,- 6.788,- 9.052,- 9.052,- 11.313,- 11.313,-140 Unit guards (to cover unit access) Lei 2.593,- 2.829,- 2.829,- 3.065,- 3.065,- 3.299,- 3.299,-Electrical / Control04 Direct on line starter (dol) Lei Standard 06 Soft starter Lei 10.583,- 12.540,- 14.024,- 17.584,- 16.687,- 20.412,- 22.415,-10 Double setpoint Lei Standard 15 Under / over voltage control Lei 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,-16 Energy meter Lei n/a 7.189,- n/a 7.189,- 7.189,-17B Capacitors for power factor correction (single-v) Lei 2.829,- 3.008,- 3.186,- 5.657,- 3.809,- 5.836,- 6.015,-57 Evaporator electric heater Lei Standard 58 Evaporator flow switch Lei 1.698,- 1.698,- 1.698,- 1.698,- 1.698,- 1.698,- 1.698,-60 Electronic expansion valve Lei

Standard67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei70 Alarm from external device Lei95 Compressors circuit breakers Lei 1.744,- 1.957,- 2.169,- 3.488,- 2.663,- 3.701,- 3.912,-96 Fans circuit breakers Lei 1.013,- 1.013,- 1.013,- 1.013,- 1.013,- 1.013,- 1.013,-

NEW

Page 29: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 29

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-SL 85 115 135 155 175 195 20597 Main switch interlock door Lei

Standard 99 Fans speed regulation (+ fan silent mode) Lei120e Inverter kit for 1 centr pump low lift Lei 4.478,- 4.855,- 4.855,- 5.610,- 5.610,- 5.610,- 5.610,-120f Inverter kit for 1 centr pump high lift Lei 5.610,- 5.610,- 5.610,- 5.610,- 5.610,- 5.610,- 5.610,-128 Master/slave Lei Standard142A High ambient kit Lei 3.394,- 4.289,- 4.289,- 5.186,- 5.186,- 6.081,- 6.081,-143 Variable primary flow Lei 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,-144 Diff pressure transd (shipped loose) Lei 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,-155 Daikin on site modem (with antenna) Lei 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,-160 100 pa esp fans Lei 1.980,- 2.876,- 2.876,- 3.770,- 3.770,- 4.667,- 4.667,-Installation75 Rubber anti vibration mounts Lei 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,-77 Spring anti vibration mounts Lei 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,-83 External tank without cabinet (500 l) Lei 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,-84 External tank without cabinet (1000 l) Lei 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,-87 External tank with cabinet (500 l) Lei 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,-88 External tank with cabinet (1000 l) Lei 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Page 30: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

30

EWAT-B-SRStandard efficiency rating, reduced noise level

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-SR 85 115 135 155 175 195 205Price Lei 88.090,- 104.551,- 116.915,- 146.509,- 139.008,- 170.116,- 235.443,-Commissioning by DAIKIN service (net price) Lei On Request On Request On Request On Request On Request On Request On RequestCooling capacity kW 76 105 124 150 165 181 200Power input kW 33,8 40,3 53,1 66 72,8 73,2 84,6Refrigerant circuit 1 1 1 2 1 2 2Compressors 2 2 2 4 2 4 4EER 2,26 2,6 2,33 2,27 2,26 2,47 2,36ESEER(+opt FANMOD)(1) 3,95 4,07 3,9 3,81 4,1 3,88 3,97Length x Width x Height mm 2.120x1.204x1.801 2.660x1.204x1.801 2.660x1.204x1.801 3.570x1.204x1.822 3.180x1.204x1.801 4.170x1.204x1.822 4.170x1.204x1.822Weight of unit / Operating weight kg 691/696 777/783 821/830 1.028/1.035 994/1.006 1.187/1.198 1.179/1.190Sound power / Sound pressure (at 1m) dB(A) 77/61 83/65 84/66 82/63 86/68 84/65 85/67Buffer tank volume / option (OP 134/135/136/137) liter 50 145 145 190 190 250 250

Optional accessories for chiller:Code Type of unit EWAT -B-SR 85 115 135 155 175 195 205Mechanical01 Total heat recovery Lei

n/a 19.280,- 24.513,- 29.934,- 29.934,- 34.931,- 38.892,-

03A Partial heat recovery with control Lei 7.802,- 10.418,- 14.378,- 10.418,- 14.378,- 14.378,-08 Brine version Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-20 Evaporator victaulic kit Lei Standard21 Evaporator flange kit Lei 848,- 848,- 848,- 848,- 848,- 848,- 848,-29 20mm evaporator insulation Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-78 One centrifugal pump (low lift) Lei 13.270,- 13.860,- 13.860,- 14.731,- 14.731,- 15.321,- 15.321,-79 One centrifugal pump (high lift) Lei 16.193,- 16.806,- 16.806,- 16.806,- 16.806,- 17.866,- 17.866,-80 Two centrifugal pump (low lift) Lei 21.920,- 21.920,- 21.920,- 22.579,- 22.579,- 23.476,- 23.476,-81 Two centrifugal pump (high lift) Lei 25.715,- 26.234,- 26.234,- 26.234,- 26.234,- 26.940,- 26.940,-91 Double pressure relief valve with diverter Lei 5.421,- 5.421,- 5.421,- 8.062,- 5.421,- 8.062,- 8.062,-115 Water filter Lei 1.509,- 1.509,- 1.509,- 1.815,- 1.509,- 1.815,- 1.815,-121 Refrigerant leak detection Lei 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,-126 Discharge and suction line shut-off valve Lei 4.525,- 4.525,- 4.525,- 9.052,- 4.525,- 9.052,- 9.052,-127 High and low pressure side manometers Lei 1.485,- 1.485,- 1.485,- 2.970,- 1.485,- 2.970,- 2.970,-134 One centrifugal pump (low lift) + tank Lei 20.859,- 23.334,- 23.334,- 24.255,- 24.255,- 24.796,- 24.796,-135 One centrifugal pump (high lift) + tank Lei 23.806,- 26.327,- 26.327,- 26.327,- 26.327,- 27.389,- 27.389,-136 Two centrifugal pump (low lift) + tank Lei 32.480,- 32.905,- 32.905,- 33.376,- 33.376,- 34.012,- 34.012,-137 Two centrifugal pump (high lift) + tank Lei 35.496,- 36.015,- 36.015,- 36.015,- 36.015,- 37.052,- 37.052,-139 E-coating microchannel coils Lei 4.525,- 6.788,- 6.788,- 9.052,- 9.052,- 11.313,- 11.313,-140 Unit guards (to cover unit access) Lei 2.593,- 2.829,- 2.829,- 3.065,- 3.065,- 3.299,- 3.299,-Electrical / Control04 Direct on line starter (dol) Lei Standard 06 Soft starter Lei 10.583,- 12.540,- 14.024,- 17.584,- 16.687,- 20.412,- 22.415,-10 Double setpoint Lei Standard 15 Under / over voltage control Lei 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,-16 Energy meter Lei n/a 7.189,- n/a 7.189,- 7.189,-17B Capacitors for power factor correction (single-v) Lei 2.829,- 3.008,- 3.186,- 5.657,- 3.809,- 5.836,- 6.015,-42 Speedtrol Lei n/a 9.146,- n/a 9.146,-57 Evaporator electric heater Lei Standard 58 Evaporator flow switch Lei 1.698,- 1.698,- 1.698,- 1.698,- 1.698,- 1.698,- 1.698,-60 Electronic expansion valve Lei

Standard67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei70 Alarm from external device Lei95 Compressors circuit breakers Lei 1.744,- 1.957,- 2.169,- 3.488,- 2.663,- 3.701,- 3.912,-

NEW

Page 31: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 31

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-SR 85 115 135 155 175 195 20596 Fans circuit breakers Lei 1.013,- 1.013,- 1.013,- 1.013,- 1.013,- 1.013,- 1.013,-97 Main switch interlock door Lei

Standard 99 Fans speed regulation (+ fan silent mode) Lei120e Inverter kit for 1 centr pump low lift Lei 4.478,- 4.855,- 4.855,- 5.610,- 5.610,- 5.610,- 5.610,-120f Inverter kit for 1 centr pump high lift Lei 5.610,- 5.610,- 5.610,- 5.610,- 5.610,- 5.610,- 5.610,-128 Master/slave Lei Standard142A High ambient kit Lei 3.394,- 4.289,- 4.289,- 5.186,- 5.186,- 6.081,- 6.081,-143 Variable primary flow Lei 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,-144 Diff pressure transd (shipped loose) Lei 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,-155 Daikin on site modem (with antenna) Lei 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,-Installation75 Rubber anti vibration mounts Lei 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,-77 Spring anti vibration mounts Lei 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,-83 External tank without cabinet (500 l) Lei 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,-84 External tank without cabinet (1000 l) Lei 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,-87 External tank with cabinet (500 l) Lei 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,-88 External tank with cabinet (1000 l) Lei 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Page 32: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

32

EWAT-B-XSHigh efficiency rating, standard noise level

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-XS 85 115 145 180 185 200Price Lei 104.308,- 119.516,- 137.436,- 179.190,- 154.516,- 245.697,-Commissioning by DAIKIN service (net price) Lei On Request On Request On Request On Request On Request On RequestCooling capacity kW 88 114 143 179 182 200Power input kW 28,9 36,5 44,5 57,2 63,8 65,7Refrigerant circuit 1 1 1 2 1 2Compressors 2 2 2 4 2 4EER 3,04 3,11 3,22 3,12 2,86 3,05ESEER(+opt FANMOD)(1) 4,07 4,23 4,19 4,3 4,05 4,13Length x Width x Height mm 2.660x1.204x1.801 3.180x1.204x1.801 3.780x1.204x1.822 2.326x2.236x2.540 3.780x1.204x1.822 2.326x2.236x2.540Weight of unit / Operating weight kg 737/742 830/836 949/958 1.633/1.644 1.066/1.078 1.663/1.674Sound power / Sound pressure (at 1m) dB(A) 86/68 89/71 91/72 91/72 92/74 93/73Buffer tank volume / option (OP 134/135/136/137) liter 145 190 190 300 250 300

Optional accessories for chiller:Code Type of unit EWAT -B-XS 85 115 145 180 185 200Mechanical01 Total heat recovery Lei 17.655,- 19.280,- 24.513,- 29.934,- 29.934,- 34.931,-03A Partial heat recovery with control Lei 7.802,- 7.802,- 10.418,- 14.378,- 10.418,- 14.378,-08 Brine version Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-20 Evaporator victaulic kit Lei Standard21 Evaporator flange kit Lei 848,- 848,- 848,- 1.132,- 848,- 1.132,-29 20mm evaporator insulation Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-61 Discharge line shut-off valve Lei

n/a

3.394,-

n/a

3.394,-62 Suction line shut-off valve Lei 5.657,- 5.657,-63 High pressure side manometers Lei 1.556,- 1.556,-64 Low pressure side manometers Lei 1.556,- 1.556,-78 One centrifugal pump (low lift) Lei 13.860,- 14.731,- 15.321,- 22.557,- 15.321,- 22.934,-79 One centrifugal pump (high lift) Lei 16.806,- 16.806,- 17.866,- 23.265,- 17.866,- 23.265,-80 Two centrifugal pump (low lift) Lei 21.920,- 22.579,- 23.476,- 32.150,- 23.476,- 32.150,-81 Two centrifugal pump (high lift) Lei 26.234,- 26.234,- 26.940,- 34.318,- 26.940,- 34.318,-91 Double pressure relief valve with diverter Lei 5.421,- 5.421,- 5.421,- 8.062,- 5.421,- 8.062,-115 Water filter Lei 1.509,- 1.509,- 1.509,- 1.815,- 1.509,- 1.815,-121 Refrigerant leak detection Lei 5.917,- 5.917,- 5.917,-

n/a5.917,-

n/a126 Discharge and suction line shut-off valve Lei 4.525,- 4.525,- 4.525,- 4.525,-127 High and low pressure side manometers Lei 1.485,- 1.485,- 1.485,- 1.485,-134 One centrifugal pump (low lift) + tank Lei 23.334,- 24.255,- 24.796,- 33.045,- 24.796,- 33.423,-135 One centrifugal pump (high lift) + tank Lei 26.327,- 26.327,- 27.389,- 33.753,- 27.389,- 33.753,-136 Two centrifugal pump (low lift) + tank Lei 32.905,- 33.376,- 34.012,- 42.638,- 34.012,- 42.638,-137 Two centrifugal pump (high lift) + tank Lei 36.015,- 36.015,- 37.052,- 44.807,- 37.052,- 44.807,-139 E-coating microchannel coils Lei 6.788,- 9.052,- 11.313,- 17.819,- 11.313,- 17.819,-140 Unit guards (to cover unit access) Lei 2.829,- 3.065,- 3.299,- 8.202,- 3.299,- 8.202,-141 Side panels on coil ends Lei

n/a

2.263,-

n/a

2.263,-153 Blue coat Lei 3.299,- 3.299,-171 Free cooling migration - light Lei 63.640,- 63.640,-172 Free cooling migration - full Lei 131.994,- 131.994,-173 Free cooling migration - full with hydro kit Lei 146.136,- 146.136,-Electrical / Control04 Direct on line starter (dol) Lei Standard 06 Soft starter Lei 13.152,- 15.061,- 17.325,- 22.579,- 19.469,- 24.584,-10 Double setpoint Lei Standard 11 Compressor thermal overload relays Lei n/a 4.733,- n/a 4.733,-15 Under / over voltage control Lei 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,-16 Energy meter Lei

n/a7.189,-

n/a7.189,-

17 Capacitors for power factor correction Lei 5.657,- 5.836,-17B Capacitors for power factor correction (single-v) Lei 2.829,- 3.008,- 3.186,- n/a 3.809,- n/a42 Speedtrol Lei n/a 9.146,- n/a 9.146,-57 Evaporator electric heater Lei Standard58 Evaporator flow switch Lei 1.698,- 1.698,- 1.698,- 2.122,- 1.698,- 2.122,-

NEW

Page 33: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 33

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-XS 85 115 145 180 185 20060 Electronic expansion valve Lei

Standard67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei70 Alarm from external device Lei95 Compressors circuit breakers Lei 1.744,- 1.957,- 2.169,- 3.488,- 2.663,- 3.701,-96 Fans circuit breakers Lei 1.013,- 1.013,- 1.013,- 1.320,- 1.013,- 1.320,-97 Main switch interlock door Lei Standard99 Fans speed regulation (+ fan silent mode) Lei Standard n/a Standard n/a99a Fans speed regulation (vfd) Lei

n/a9.923,-

n/a9.923,-

102 Ground fault relay Lei 4.267,- 4.267,-120e Inverter kit for 1 centr pump low lift Lei 4.855,- 5.610,- 5.610,- 5.279,- 5.610,- 5.751,-120f Ínverter kit for 1 centr pump high lift Lei 5.610,- 5.610,- 5.610,- 6.058,- 5.610,- 6.058,-120g Inverter kit for 2 centr pump low lift Lei

n/a11.502,-

n/a11.502,-

120h Inverter kit for 2 centr pump high lift Lei 15.603,- 15.603,-128 Master/slave Lei Standard142A High ambient kit Lei 4.289,- 5.186,- 6.081,- 5.515,- 6.081,- 5.515,-143 Variable primary flow Lei 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,-144 Diff pressure transd (shipped loose) Lei 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,-155 Daikin on site modem (with antenna) Lei 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,-160 100 pa esp fans Lei 2.876,- 3.770,- 4.667,- n/a 4.667,- n/a161 200 pa esp fans Lei n/a 57.701,- n/a 57.701,-Installation75 Rubber anti vibration mounts Lei 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,-77 Spring anti vibration mounts Lei 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,-83 External tank without cabinet (500 l) Lei 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,-84 External tank without cabinet (1000 l) Lei 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,-87 External tank with cabinet (500 l) Lei 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,-88 External tank with cabinet (1000 l) Lei 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Page 34: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

34

EWAT-B-XLHigh efficiency rating, low noise level

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-XL 85 115 145 180 185 200Price Lei 106.402,- 121.911,- 140.187,- 190.844,- 157.621,- 261.677,-Commissioning by DAIKIN service (net price) Lei On Request On Request On Request On Request On Request On RequestCooling capacity kW 88 114 143 179 182 200Power input kW 28,9 36,5 44,5 57,2 63,8 65,7Refrigerant circuit 1 1 1 2 1 2Compressors 2 2 2 4 2 4EER 3,04 3,11 3,22 3,12 2,86 3,05ESEER(+opt FANMOD)(1) 4,07 4,23 4,19 4,3 4,05 4,13Length x Width x Height mm 2.660x1.204x1.801 3.180x1.204x1.801 3.780x1.204x1.822 2.326x2.236x2.540 3.780x1.204x1.822 2.326x2.236x2.540Weight of unit / Operating weight kg 747/752 840/846 959/968 1.736/1.747 1.076/1.088 1.766/1.777Sound power / Sound pressure (at 1m) dB(A) 85/68 87/69 89/70 91/72 89/71 91/72Buffer tank volume / option (OP 134/135/136/137) liter 145 190 190 300 250 300

Optional accessories for chiller:Code Type of unit EWAT -B-XL 85 115 145 180 185 200Mechanical01 Total heat recovery Lei 17.655,- 19.280,- 24.513,- 29.934,- 29.934,- 34.931,-03A Partial heat recovery with control Lei 7.802,- 7.802,- 10.418,- 14.378,- 10.418,- 14.378,-08 Brine version Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-20 Evaporator victaulic kit Lei Standard21 Evaporator flange kit Lei 848,- 848,- 848,- 1.132,- 848,- 1.132,-29 20mm evaporator insulation Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-61 Discharge line shut-off valve Lei

n/a

3.394,-

n/a

3.394,-62 Suction line shut-off valve Lei 5.657,- 5.657,-63 High pressure side manometers Lei 1.556,- 1.556,-64 Low pressure side manometers Lei 1.556,- 1.556,-78 One centrifugal pump (low lift) Lei 13.860,- 14.731,- 15.321,- 22.557,- 15.321,- 22.934,-79 One centrifugal pump (high lift) Lei 16.806,- 16.806,- 17.866,- 23.265,- 17.866,- 23.265,-80 Two centrifugal pump (low lift) Lei 21.920,- 22.579,- 23.476,- 32.150,- 23.476,- 32.150,-81 Two centrifugal pump (high lift) Lei 26.234,- 26.234,- 26.940,- 34.318,- 26.940,- 34.318,-91 Double pressure relief valve with diverter Lei 5.421,- 5.421,- 5.421,- 8.062,- 5.421,- 8.062,-115 Water filter Lei 1.509,- 1.509,- 1.509,- 1.815,- 1.509,- 1.815,-121 Refrigerant leak detection Lei 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,-126 Discharge and suction line shut-off valve Lei 4.525,- 4.525,- 4.525,-

n/a4.525,-

n/a127 High and low pressure side manometers Lei 1.485,- 1.485,- 1.485,- 1.485,-134 One centrifugal pump (low lift) + tank Lei 23.334,- 24.255,- 24.796,- 33.045,- 24.796,- 33.423,-135 One centrifugal pump (high lift) + tank Lei 26.327,- 26.327,- 27.389,- 33.753,- 27.389,- 33.753,-136 Two centrifugal pump (low lift) + tank Lei 32.905,- 33.376,- 34.012,- 42.638,- 34.012,- 42.638,-137 Two centrifugal pump (high lift) + tank Lei 36.015,- 36.015,- 37.052,- 44.807,- 37.052,- 44.807,-139 E-coating microchannel coils Lei 6.788,- 9.052,- 11.313,- 17.819,- 11.313,- 17.819,-140 Unit guards (to cover unit access) Lei 2.829,- 3.065,- 3.299,- 8.202,- 3.299,- 8.202,-141 Side panels on coil ends Lei

n/a

2.263,-

n/a

2.263,-153 Blue coat Lei 3.299,- 3.299,-171 Free cooling migration - light Lei 63.640,- 63.640,-172 Free cooling migration - full Lei 131.994,- 131.994,-173 Free cooling migration - full with hydro kit Lei 146.136,- 146.136,-Electrical / Control04 Direct on line starter (dol) Lei Standard 06 Soft starter Lei 13.152,- 15.061,- 17.325,- 22.579,- 19.469,- 24.584,-10 Double setpoint Lei Standard 11 Compressor thermal overload relays Lei n/a 4.733,- n/a 4.733,-15 Under / over voltage control Lei 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,-16 Energy meter Lei

n/a7.189,-

n/a7.189,-

17 Capacitors for power factor correction Lei 5.657,- 5.836,-17B Capacitors for power factor correction (single-v) Lei 2.829,- 3.008,- 3.186,- n/a 3.809,- n/a42 Speedtrol Lei n/a 9.146,- n/a 9.146,-57 Evaporator electric heater Lei Standard58 Evaporator flow switch Lei 1.698,- 1.698,- 1.698,- 2.122,- 1.698,- 2.122,-

NEW

Page 35: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 35

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-XL 85 115 145 180 185 20060 Electronic expansion valve Lei

Standard67 Ambient outside temperature sensor and setpoint reset Lei68 Hour run meter Lei69 General fault contactor Lei70 Alarm from external device Lei95 Compressors circuit breakers Lei 1.744,- 1.957,- 2.169,- 3.488,- 2.663,- 3.701,-96 Fans circuit breakers Lei 1.013,- 1.013,- 1.013,- 1.320,- 1.013,- 1.320,-97 Main switch interlock door Lei Standard99 Fans speed regulation (+ fan silent mode) Lei Standard n/a Standard n/a99a Fans speed regulation (vfd) Lei

n/a9.923,-

n/a9.923,-

102 Ground fault relay Lei 4.267,- 4.267,-120e Inverter kit for 1 centr pump low lift Lei 4.855,- 5.610,- 5.610,- 5.279,- 5.610,- 5.751,-120f Ínverter kit for 1 centr pump high lift Lei 5.610,- 5.610,- 5.610,- 6.058,- 5.610,- 6.058,-120g Inverter kit for 2 centr pump low lift Lei

n/a11.502,-

n/a11.502,-

120h Inverter kit for 2 centr pump high lift Lei 15.603,- 15.603,-128 Master/slave Lei Standard142A High ambient kit Lei 4.289,- 5.186,- 6.081,- 5.515,- 6.081,- 5.515,-143 Variable primary flow Lei 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,-144 Diff pressure transd (shipped loose) Lei 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,-155 Daikin on site modem (with antenna) Lei 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,-160 100 pa esp fans Lei 2.876,- 3.770,- 4.667,- n/a 4.667,- n/a161 200 pa esp fans Lei n/a 57.701,- n/a 57.701,-Installation75 Rubber anti vibration mounts Lei 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,-77 Spring anti vibration mounts Lei 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,-83 External tank without cabinet (500 l) Lei 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,-84 External tank without cabinet (1000 l) Lei 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,-87 External tank with cabinet (500 l) Lei 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,-88 External tank with cabinet (1000 l) Lei 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Page 36: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

36

EWAT-B-XRHigh efficiency rating, reduced noise level

Air cooled chiller

Type of unit (rated power in accordance with EN14511) EWAT -B-XR 85 115 145 180 185 200Price Lei 109.601,- 125.577,- 144.396,- 199.131,- 162.354,- 272.166,-Commissioning by DAIKIN service (net price) Lei On Request On Request On Request On Request On Request On RequestCooling capacity kW 82 108 135 168 166 187Power input kW 30,9 39 47,1 59,1 70,5 69,8Refrigerant circuit 1 1 1 2 1 2Compressors 2 2 2 4 2 4EER 2,64 2,78 2,88 2,84 2,35 2,68ESEER(+opt FANMOD)(1) 4,02 4,18 4,08 4,24 4,04 4,21Length x Width x Height mm 2.660x1.204x1.801 3.180x1.204x1.801 3.780x1.204x1.822 2.326x2.236x2.540 3.780x1.204x1.822 2.326x2.236x2.540Weight of unit / Operating weight kg 747/752 840/846 959/968 1.736/1.747 1.076/1.088 1.776/1.777Sound power / Sound pressure (at 1m) dB(A) 78/60 82/64 84/66 84/65 86/68 85/66Buffer tank volume / option (OP 134/135/136/137) liter 145 190 190 300 250 300

Optional accessories for chiller:Code Type of unit EWAT -B-XR 85 115 145 180 185 200Mechanical01 Total heat recovery Lei 17.655,- 19.280,- 24.513,- 29.934,- 29.934,- 34.931,-03A Partial heat recovery with control Lei 7.802,- 7.802,- 10.418,- 14.378,- 10.418,- 14.378,-08 Brine version Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-20 Evaporator victaulic kit Lei Standard21 Evaporator flange kit Lei 848,- 848,- 848,- 1.132,- 848,- 1.132,-29 20mm evaporator insulation Lei 1.603,- 1.603,- 1.603,- 1.603,- 1.603,- 1.603,-61 Discharge line shut-off valve Lei

n/a

3.394,-

n/a

3.394,-62 Suction line shut-off valve Lei 5.657,- 5.657,-63 High pressure side manometers Lei 1.556,- 1.556,-64 Low pressure side manometers Lei 1.556,- 1.556,-78 One centrifugal pump (low lift) Lei 13.860,- 14.731,- 15.321,- 22.557,- 15.321,- 22.934,-79 One centrifugal pump (high lift) Lei 16.806,- 16.806,- 17.866,- 23.265,- 17.866,- 23.265,-80 Two centrifugal pump (low lift) Lei 21.920,- 22.579,- 23.476,- 32.150,- 23.476,- 32.150,-81 Two centrifugal pump (high lift) Lei 26.234,- 26.234,- 26.940,- 34.318,- 26.940,- 34.318,-91 Double pressure relief valve with diverter Lei 5.421,- 5.421,- 5.421,- 8.062,- 5.421,- 8.062,-115 Water filter Lei 1.509,- 1.509,- 1.509,- 1.815,- 1.509,- 1.815,-121 Refrigerant leak detection Lei 5.917,- 5.917,- 5.917,- 5.917,- 5.917,- 5.917,-126 Discharge and suction line shut-off valve Lei 4.525,- 4.525,- 4.525,-

n/a4.525,-

n/a127 High and low pressure side manometers Lei 1.485,- 1.485,- 1.485,- 1.485,-134 One centrifugal pump (low lift) + tank Lei 23.334,- 24.255,- 24.796,- 33.045,- 24.796,- 33.423,-135 One centrifugal pump (high lift) + tank Lei 26.327,- 26.327,- 27.389,- 33.753,- 27.389,- 33.753,-136 Two centrifugal pump (low lift) + tank Lei 32.905,- 33.376,- 34.012,- 42.638,- 34.012,- 42.638,-137 Two centrifugal pump (high lift) + tank Lei 36.015,- 36.015,- 37.052,- 44.807,- 37.052,- 44.807,-139 E-coating microchannel coils Lei 6.788,- 9.052,- 11.313,- 17.819,- 11.313,- 17.819,-140 Unit guards (to cover unit access) Lei 2.829,- 3.065,- 3.299,- 8.202,- 3.299,- 8.202,-141 Side panels on coil ends Lei

n/a

2.263,-

n/a

2.263,-153 Blue coat Lei 3.299,- 3.299,-171 Free cooling migration - light Lei 58.926,- 58.926,-172 Free cooling migration - full Lei 127.280,- 127.280,-173 Free cooling migration - full with hydro kit Lei 141.422,- 141.422,-Electrical / Control04 Direct on line starter (dol) Lei Standard 06 Soft starter Lei 13.152,- 15.061,- 17.325,- 22.579,- 19.469,- 24.584,-10 Double setpoint Lei Standard 11 Compressor thermal overload relays Lei n/a 4.733,- n/a 4.733,-15 Under / over voltage control Lei 1.367,- 1.367,- 1.367,- 1.367,- 1.367,- 1.367,-16 Energy meter Lei

n/a7.189,-

n/a7.189,-

17 Capacitors for power factor correction Lei 5.657,- 5.836,-17B Capacitors for power factor correction (single-v) Lei 2.829,- 3.008,- 3.186,- n/a 3.809,- n/a57 Evaporator electric heater Lei Standard58 Evaporator flow switch Lei 1.664,- 1.664,- 1.664,- 2.080,- 1.664,- 2.080,-60 Electronic expansion valve Lei Standard

NEW

Page 37: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 37

Air cooled chiller

Optional accessories for chiller:

Code Type of unit EWAT -B-XR 85 115 145 180 185 20067 Ambient outside temperature sensor and setpoint reset Lei

Standard68 Hour run meter Lei69 General fault contactor Lei70 Alarm from external device Lei95 Compressors circuit breakers Lei 1.744,- 1.957,- 2.169,- 3.488,- 2.663,- 3.701,-96 Fans circuit breakers Lei 1.013,- 1.013,- 1.013,- 1.320,- 1.013,- 1.320,-97 Main switch interlock door Lei Standard99 Fans speed regulation (+ fan silent mode) Lei Standard n/a Standard n/a99a Fans speed regulation (vfd) Lei n/a Standard n/a Standard102 Ground fault relay Lei n/a 4.267,- n/a 4.267,-120e Inverter kit for 1 centr pump low lift Lei 4.855,- 5.610,- 5.610,- 5.279,- 5.610,- 5.751,-120f Ínverter kit for 1 centr pump high lift Lei 5.610,- 5.610,- 5.610,- 6.058,- 5.610,- 6.058,-120g Inverter kit for 2 centr pump low lift Lei

n/a11.502,-

n/a11.502,-

120h Inverter kit for 2 centr pump high lift Lei 15.603,- 15.603,-128 Master/slave Lei Standard142A High ambient kit Lei 4.289,- 5.186,- 6.081,- 5.515,- 6.081,- 5.515,-143 Variable primary flow Lei 9.192,- 9.192,- 9.192,- 9.192,- 9.192,- 9.192,-144 Diff pressure transd (shipped loose) Lei 8.226,- 8.226,- 8.226,- 8.226,- 8.226,- 8.226,-155 Daikin on site modem (with antenna) Lei 4.336,- 4.336,- 4.336,- 4.336,- 4.336,- 4.336,-Installation75 Rubber anti vibration mounts Lei 2.216,- 2.216,- 2.216,- 2.216,- 2.216,- 2.216,-77 Spring anti vibration mounts Lei 6.977,- 6.977,- 6.977,- 6.977,- 6.977,- 6.977,-83 External tank without cabinet (500 l) Lei 17.253,- 17.253,- 17.253,- 17.253,- 17.253,- 17.253,-84 External tank without cabinet (1000 l) Lei 23.028,- 23.028,- 23.028,- 23.028,- 23.028,- 23.028,-87 External tank with cabinet (500 l) Lei 25.384,- 25.384,- 25.384,- 25.384,- 25.384,- 25.384,-88 External tank with cabinet (1000 l) Lei 32.503,- 32.503,- 32.503,- 32.503,- 32.503,- 32.503,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-(1) Option FANMOD consist in Continuous Fan Speed Regulation and improves part load operation, Single-V units are standardly equipped with continuous fan control, Modular-V units require opt 99a – VFD fans

Page 38: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

38

EWWQ-KBW1N ʯ One of the most compact units on the market ʯ Low energy consumption ʯ Low operating sound level ʯ Low refrigerant volume ʯ Stainless steel plate heat exchanger ʯ Extension possible to 183 kW ʯ Easy installation and maintenance ʯ Remote cooling or heating selection ʯ Water/water heat pump, with water reversibility ʯ Standard integrated: main switch, water filter, flow switch, air purge, and pressure ports

Water cooled chiller

Unit size EWWQ014KBW1N EWWQ025KBW1N EWWQ033KBW1N EWWQ049KBW1N Price Lei 21.749,- 29.191,- 33.801,- 46.091,-Cooling capacity kW 13,25 23,9 30,4 47,15Heating capacity(2) kW 16,4 29,85 38,76 57,59EER 4,21 4,18 4,16 4,13ESEER 4,52 4,58 4,72 4,56Heat rejection capacity kW 16,04 29,13 37,75 57,45Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 178 189 200 192

SCOP 4,65 4,94 5,2 5,01Seasonal space heating eff. class A+++

Sound power level dB(A) 64 64 71 67

OptionsOPZH glycol application to -5 °C LWE Lei 1.093,- 1.093,- 1.093,- 1.093,-OPZL glycol application to -10 °C LWE Lei 1.093,- 1.093,- 1.093,- 1.093,-

KitEKLS1 low noise kit 5 HP Lei 1.411,- – – – EKLS2 low noise kit 8/10/12 HP Lei – 1.366,- 1.366,- 1.366,-EKAC10C(3) BMS address card Lei 778,- 778,- 778,- 778,-EKRUMCA remote user interface Lei 1.439,- 1.439,- 1.439,- 1.439,-

Unit size EWWQ064KBW1N EWWQ049KAW1M* EWWQ064KAW1M*Price Lei 54.628,- 37.898,- 46.434,-Cooling capacity(1) kW 60,98 47,15 60,98Heating capacity(2) kW 75,17 57,59 75,17EER 4,18 4,13 4,18ESEER 4,71 4,56 4,71Heat rejection capacity kW 74,44 57,45 74,44Space heating

Average climate water outlet 35°C

General ηs (Seasonal space heating efficiency)

% 197 192 197

SCOP 5,14 5,01 5,14Seasonal space heating eff. class A+++

Sound power level dB(A) 74 67 64(*) Multi modular unit for two or three module application, controller is available in options

OptionsOPZH glycol application to -5 °C LWE Lei 1.093,- 1.093,- 1.093,-OPZL glycol application to -10 °C LWE Lei 1.093,- 1.093,- 1.093,-

KitEKLS2 low noise kit 8/10/12 HP (2 pcs.) Lei 1.366,- 1.366,- 1.366,-EKAC10C(3) BMS address card Lei 778,- 778,- 778,-EKRUMCA (3) remote user interface Lei 1.439,- 1.439,- 1.439,-

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

(3) EKAC10C is needed for direct BMS connection via Modbus and to install EKRUMCA

Page 39: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 39

EWWQ-KBW1M ʯ Designed for indoor installation ʯ Cooling and/or heating application possible ʯ Available in 11 standards sizes ʯ Capacity range from 98 to 192 kW ʯ Combining with FCU and AHU for air conditioning purpose ʯ Supplying chilled water for process cooling ʯ Easy installation and maintenance

Water cooled chiller

Capacity index 098 113 128

Basic model EWWQ049KAW1MEWWQ049KAW1M

EWWQ049KAW1MEWWQ064KAW1M

EWWQ064KAW1MEWWQ064KAW1M

Control box ECB2MUBW ECB2MUBW ECB2MUBWPrice Lei 91.467,- 100.002,- 108.539,-Cooling capacity(1) kW 94,39 108,2 122,1Heating capacity(2) kW 115,2 132,8 150,3Sound power level dB(A) 56 60 62

OptionsOPZH glycol application to -5°C LWE Lei 2.185,- 2.185,- 2.185,-OPZL glycol application to -10°C LWE Lei 2.185,- 2.185,- 2.185,-

Capacity index 147 162 177 192

Basic modelEWWQ049KAW1M EWWQ049KAW1MEWWQ049KAW1M

EWWQ049KAW1M EWWQ049KAW1M EWWQ064KAW1M

EWWQ049KAW1M EWWQ064KAW1M EWWQ064KAW1M

EWWQ064KAW1M EWWQ064KAW1M EWWQ064KAW1M

Control box ECB3MUBW ECB3MUBW ECB3MUBW ECB3MUBWPrice Lei 129.364,- 137.900,- 146.436,- 154.973,-Cooling capacity kW 141,6 155,5 163,3 183,2Heating capacity(2) kW 172,8 190,3 207,9 225,5Sound power level dB(A) 57 61 62 63

OptionsOPZH glycol application to -5°C LWE Lei 3.278,- 3.278,- 3.278,- 3.278,-OPZL glycol application to -10°C LWE Lei 3.278,- 3.278,- 3.278,- 3.278,-

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) Heating: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C), data according EN 14511: 2011

Page 40: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

40

Water cooled chiller

EWW(H)Q-G(L)-SS ʯ Compact Water/Water Chiller with Scroll compressors ʯ Refrigerant R410A ʯ Evaporator as plate heat exchanger ʯ Condenser as plate heat exchanger ʯ Certified by Eurovent ʯ High efficiency rating – Eurovent rating Class A ʯ Electronic expansion valve ʯ Sequential control for Master/Slave function as standard feature ʯ Partial heat recovery optionally available ʯ Soundproof enclosure (Sound Proof System) optionally available ʯ Installed pump optionally available

Operating limits (cooling only): Condenser outlet temperature: +25°C to + 55°CEvaporator outlet temperature: -10°C to + 15°C

Standard equipment › Main switch › Direct start › Double setpoint value › Evaporator electric heater › Electronic expansion valve › Evaporator insulation 20 mm › Accumulative fault message

cond

ense

r lea

ving

wat

er te

mpe

ratu

re

(con

dens

er o

utle

t tem

pera

ture

) [o C

]

60 operating limits

55

50

45

40

35

30

25

20-11 -8 -5 -2 1 4 7 10 13 16

Evaporator leaving water temperature [oC]

Operation with glycol

Page 41: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 41

EWWQ-G-SSOne refrigerant circuit, standard efficiency rating

ʯ Single refrigerant circuit (2 scroll compressors) with single evaporator

ʯ Compact design to allow easy indoor installation or retrofit operations

ʯ Conceived for stacked installation of two single circuit units to reduce the footprint

ʯ Allows sequencing control (up to 4 units) without any external device

ʯ Stainless steel plate heat exchanger ʯ Pump (low 100 kPa and high 200 kPa lift) available for evaporator and condenser

Type of unit (rated power in accordance with EN14511) EWWQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Price Lei 81.026,- 86.422,- 92.272,- 98.492,- 104.207,- 114.334,- 123.373,- 126.154,- 134.879,- 163.175,- 186.022,-Commissioning by DAIKIN service (net price) Lei 3.484,- 3.484,- 3.484,- 3.484,- 4.255,- 4.255,- 4.255,- 4.255,- 4.255,- 4.255,- 4.255,-Cooling capacity kW 93,7 106 119 136 150 172 194 221 246 314 370Power input kW 21,3 24 26,9 30,5 33,9 38,9 43,8 51,2 56,6 70,2 84Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2 2 2 2 2EER 4,4 4,4 4,42 4,46 4,42 4,42 4,42 4,31 4,34 4,48 4,41ESEER 5,51 5,52 5,51 5,53 5,51 5,53 5,52 5,52 5,52 5,52 5,52Length x Width x Height mm 2.432 x 928 x 1.066 2.264 x 928 x 1.066 2.432 x 928 x 1.066 2.432 x 928 x 1.186Weight of unit / Operating weight kg 516/ 555 606/ 652 728/ 782 762/ 821 795/ 859 832/ 901 871/ 946 921/ 1.010 934/ 1.023 1.083/ 1.195 1.181/ 1.311Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency) % 163 163 165 168 168 168 167 164 162 166 -

SCOP 4,28 4,28 4,33 4,40 4,39 4,40 4,38 4,29 4,25 4,34 -Sound power / Sound pressure (at 1m) dB(A) 80/ 64 83/ 67 85/ 69 87/ 70 88/ 72 88/ 72 88/ 72 90/ 74 92/ 76 93/ 76 93/ 77

Optional accessories for chiller:

Code Type of unit EWWQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Mechanical130 Evaporator and condenser victaulic kit Lei

Standard 29 20Mm evaporator insulation Lei60 Electronic expansion valve Lei07a Heat pump version (with reversibility on water side) Lei 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,-133 Stacked installation Lei 7.526,- 7.526,- 7.526,- 7.526,- 7.526,- 7.526,- 7.526,- 7.526,- 7.526,- 7.526,- 7.526,-08 Brine version Lei 2.187,- 2.187,- 2.187,- 2.187,- 2.187,- 2.187,- 2.187,- 2.187,- 2.187,- 2.187,- 2.187,-03 Partial heat recovery Lei 5.151,- 5.151,- 5.151,- 5.226,- 5.257,- 6.145,- 6.330,- 6.734,- 7.967,- 8.426,- 8.974,-33 20Mm condenser insulation Lei 793,- 793,- 793,- 793,- 793,- 793,- 793,- 793,- 793,- 793,- 793,-126 Discharge and suction line shut-off valve Lei 3.640,- 3.640,- 3.640,- 3.640,- 3.640,- 3.640,- 3.640,- 3.640,- 3.640,- 3.640,- 3.640,-127 High and low pressure side manometers Lei 1.188,- 1.188,- 1.188,- 1.188,- 1.188,- 1.188,- 1.188,- 1.188,- 1.188,- 1.188,- 1.188,-76-c Sound proof system (compressors jacket) Lei 4.178,- 3.780,- 3.404,- 3.404,- 3.404,- 3.404,- 3.404,- Not available76-b Sound proof system (compressor) Lei 13.726,- 13.726,- 13.726,- 13.726,- 13.726,- 13.726,- 13.726,- 13.726,- 13.726,- 13.726,- 13.726,-91 Double pressure relief valve with diverter Lei 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,-115 Water filter Lei 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 3.589,-122 Evaporator single pump (low lift) Lei 5.321,- 5.321,- 5.665,- 5.665,- 5.665,- 9.389,- 9.389,- 9.389,- 9.389,- 9.389,- 8.714,-123 Evaporator single pump (high lift) Lei 6.114,- 6.114,- 6.509,- 6.509,- 6.509,- 10.801,- 10.801,- 10.801,- 10.801,- 10.801,- 10.023,-124 Condenser single pump (low lift) Lei 6.378,- 6.378,- 6.788,- 6.788,- 6.788,- 11.275,- 11.275,- 11.275,- 11.275,- 11.275,- 10.461,-125 Condenser single pump (high lift) Lei 7.343,- 7.343,- 7.807,- 7.807,- 7.807,- 12.967,- 12.967,- 12.967,- 12.967,- 12.967,- 12.024,-Electrical / Control04 Dol starter Lei Standard Not available132 Part winidng start Lei Not available Standard 10 Double setpoint Lei

Standard

Not available 68 Hour run meter Lei

Standard 69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 12.379,- 11.275,- 10.182,- 10.912,- 11.639,- 12.493,- 13.352,- 14.195,- 14.549,- Not available

15a Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,-

17 Capacitors for power factor correction Lei 3.319,- 3.319,- 3.319,- 3.319,- 3.319,- 3.319,- 5.865,- 5.865,- 5.865,- 8.200,- 8.200,-58 Evaporator flow switch Lei 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,-59 Condenser flow switch Lei 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,-95 Compressors circuit breakers Lei 1.392,- 1.448,- 1.507,- 1.507,- 1.507,- 1.703,- 1.907,- 1.982,- 2.056,- 6.992,- 11.929,-102 Ground fault relay Lei 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,-Installation75 Rubber anti vibration mounts Lei 869,- 869,- 869,- 869,- 869,- 869,- 869,- 869,- 869,- 869,- 869,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Water cooled chiller

Page 42: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

42

EWHQ-G-SS

One refrigerant circuit, standard efficiency rating With reversible refrigerant circuit

Type of unit (rated power in accordance with EN14511) EWHQ-G-SS 100 120 130 150 160 190 210 240 270 340 400Price Lei 92.450,- 98.624,- 105.293,- 112.375,- 118.907,- 130.465,- 132.496,- 143.954,- 153.918,- 186.202,- 212.265,-Commissioning by DAIKIN service personnel (net price) Lei 3.484,- 3.484,- 3.484,- 3.484,- 4.255,- 4.255,- 4.255,- 4.255,- 4.255,- 4.255,- 4.255,-Cooling capacity kW 87,3 100 111 127 141 160 181 208 232 291 352Power input kW 22,4 25,3 28,5 32,0 35,6 41,1 46,0 53,3 59,1 73,7 88,4Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2 2 2 2 2EER 3,90 3,95 3,91 3,96 3,95 3,90 3,93 3,90 3,92 3,95 3,98ESEER 4,70 4,84 4,65 4,86 4,80 4,89 4,86 4,83 4,79 4,90 4,83Length mm 2.432 2.432 2.264 2.264 2.264 2.432 2.432 2.432 2.432 2.432 2.432Width mm 928 928 928 928 928 928 928 928 928 928 928Height mm 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.186 1.186Weight of unit / Operating weight kg 519/558 608/654 728/782 770/830 808/873 838/908 880/955 930/1.019 941/1.031 1.090/1.202 1.203/1.334Space heating

Average climate water outlet 35°C

ηs (Seasonal space heating efficiency)

% 155 155 158 162 161 161 161 167 166 158 -

SCOP 4,08 4,08 4,14 4,24 4,23 4,23 4,22 4,37 4,35 4,16 -Sound power / Sound pressure (at 1m) dB(A) 80/64 83/67 85/69 87/70 88/72 88/72 88/72 90/74 92/76 93/76 93/77

Water cooled heat pump

Optional accessories for chiller:

Code Type of unit EWHQ-G-SS 100 120 130 150 160 190 210 240 270 340 400Mechanical130 Evaporator and condenser victaulic kit Lei

Standard 29 20Mm evaporator insulation Lei33 20Mm condenser insulation Lei60 Electronic expansion valve Lei133 Stacked installation Lei 7.601,- 7.601,- 7.601,- 7.601,- 7.601,- 7.601,- 7.601,- 7.601,- 7.601,- 7.601,- 7.601,-08 Brine version Lei 2.208,- 2.208,- 2.208,- 2.208,- 2.208,- 2.208,- 2.208,- 2.208,- 2.208,- 2.208,- 2.208,-03 Partial heat recovery Lei 5.202,- 5.202,- 5.202,- 5.277,- 5.308,- 6.206,- 6.392,- 6.800,- 8.044,- 8.509,- 9.062,-129 Liquid line dìshut of valve Lei 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.406,- 1.406,- 1.406,- 1.406,- 1.599,- 1.599,-126 Discharge and suction line shut-off valve Lei 3.675,- 3.675,- 3.675,- 3.675,- 3.675,- 3.675,- 3.675,- 3.675,- 3.675,- 3.675,- 3.675,-127 High and low pressure side manometers Lei 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.199,- 1.199,-76-c Sound proof system (compressors jacket) Lei 4.219,- 3.816,- 3.437,- 3.437,- 3.437,- 3.437,- 3.437,- Not available76-b Sound proof system (compressor) Lei 13.861,- 13.861,- 13.861,- 13.861,- 13.861,- 13.861,- 13.861,- 13.861,- 13.861,- 13.861,- 13.861,-91 Double pressure relief valve with diverter Lei 4.400,- 4.400,- 4.400,- 4.400,- 4.400,- 4.400,- 4.400,- 4.400,- 4.400,- 4.400,- 4.400,-115 Water filter Lei 2.303,- 2.303,- 2.303,- 2.303,- 2.303,- 2.303,- 2.303,- 2.303,- 2.303,- 2.303,- 3.623,-122 Evaporator single pump (low lift) Lei 5.373,- 5.373,- 5.720,- 5.720,- 5.720,- 9.481,- 9.481,- 9.481,- 9.481,- 9.481,- 8.800,-123 Evaporator single pump (high lift) Lei 6.174,- 6.174,- 6.572,- 6.572,- 6.572,- 10.908,- 10.908,- 10.908,- 10.908,- 10.908,- 10.122,-124 Condenser single pump (low lift) Lei 5.373,- 5.373,- 5.720,- 5.720,- 5.720,- 9.481,- 9.481,- 9.481,- 9.481,- 9.481,- 8.800,-125 Condenser single pump (high lift) Lei 6.174,- 6.174,- 6.572,- 6.572,- 6.572,- 10.908,- 10.908,- 10.908,- 10.908,- 10.908,- 10.122,-Electrical / Control04 Dol starter Lei Standard Not available132 Part winidng start Lei Not available10 Double setpoint Lei

Standard 68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 12.499,- 11.387,- 10.282,- 11.019,- 11.753,- 12.616,- 13.483,- 14.335,- 14.692,- Not available

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965) Lei 1.804,- 1.804,- 1.804,- 1.804,- 1.804,- 1.804,- 1.804,- 1.804,- 1.804,- 1.804,- 1.804,-

17 Capacitors for power factor correction Lei 3.352,- 3.352,- 3.352,- 3.352,- 3.352,- 3.352,- 5.923,- 5.923,- 5.923,- 8.280,- 8.280,-58 Evaporator flow switch Lei 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,-59 Condenser flow switch Lei 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,- 1.039,-95 Compressors circuit breakers Lei 1.406,- 1.463,- 1.521,- 1.521,- 1.521,- 1.719,- 1.926,- 2.001,- 2.077,- 7.061,- 12.046,-102 Ground fault relay Lei 3.482,- 3.482,- 3.482,- 3.482,- 3.482,- 3.482,- 3.482,- 3.482,- 3.482,- 3.482,- 3.482,-Installation75 Rubber anti vibration mounts Lei 877,- 877,- 877,- 877,- 877,- 877,- 877,- 877,- 877,- 877,- 877,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

ʯ Operating limits cooling: Condenser outlet temperature: +25°C to + 55°C Evaporator outlet temperature: -10°C to + 15°C ʯ Operating limits heating:

Condenser outlet temperature: +20°C to + 50°C Evaporator outlet temperature: -8°C to + 15°C

Page 43: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 43

EWWQ-L-SS

Standard efficiency rating, two refrigerant circuits

Type of unit (rated power in accordance with EN14511) EWWQ-L-SS 180 205 230 260 290 330Price Lei 153.352,- 154.610,- 165.825,- 176.627,- 188.732,- 204.145,-Commissioning by DAIKIN service personnel (net price) Lei 5.799,- 5.799,- 5.799,- 5.799,- 5.799,- 5.799,-Cooling capacity kW 187 215 244 273 303 345Power input kW 41,7 47,3 53,1 60,2 67,1 77,1Refrigerant circuit 2 2 2 2 2 2Compressors 4 4 4 4 4 4EER 4,49 4,55 4,6 4,53 4,52 4,47ESEER 5,54 5,54 5,52 5,53 5,54 5,53Length mm 2.801 2.801 2.801 2.801 2.801 2.801Width mm 928 928 928 928 928 928Height mm 1.970 1.970 1.970 1.970 1.970 1.970Weight of unit / Operating weight kg 877/957 1.062/1.156 1.285/1.401 1.347/1.469 1.439/1.575 1.498/1.641Space heating Average climate

water outlet 35°C

ηs (Seasonal space heating efficiency)

% 155 155 158 162 161 -

SCOP 4,08 4,08 4,14 4,24 4,23 -Sound power / Sound pressure (at 1m) dB(A) 83/65 86/68 88/70 90/72 91/74 91/74

Water cooled chiller

ʯ Operating limits cooling: Condenser outlet temperature: +25°C to + 55°C Evaporator outlet temperature: -10°C to + 15°C ʯ Operating limits heating:

Condenser outlet temperature: +20°C to + 50°C Evaporator outlet temperature: -8°C to + 15°C

Optional accessories for chiller:

Code Type of unit 180 205 230 260 290 330Mechanical130 Evaporator and condenser victaulic kit Lei

Standard 29 20Mm evaporator insulation Lei60 Electronic expansion valve Lei

07a Heat pump version with reversibility on water side (including pursuit mode) Lei 1.392,- 1.392,- 1.392,- 1.392,- 1.392,- 1.392,-

08 Brine version Lei 4.358,- 4.358,- 4.358,- 4.358,- 4.358,- 4.358,-03 Partial heat recovery Lei 10.557,- 10.557,- 10.557,- 10.557,- 10.706,- 12.668,-33 20Mm condenser insulation Lei 1.582,- 1.582,- 1.582,- 1.582,- 1.582,- 1.582,-126 Discharge and suction line shut-off valve Lei 7.293,- 7.293,- 7.293,- 7.293,- 7.293,- 7.293,-127 High and low pressure side manometers Lei 2.376,- 2.376,- 2.376,- 2.376,- 2.376,- 2.376,-76-c Sound proof system (compressors jacket) Lei 9.743,- 8.835,- 7.922,- 7.922,- 7.922,- 7.922,-76-b Sound proof system (compressor) Lei 27.453,- 27.453,- 27.453,- 27.453,- 27.453,- 27.453,-91 Double pressure relief valve with diverter Lei 6.518,- 6.518,- 6.518,- 6.518,- 6.518,- 6.518,-115 Water filter Lei 2.281,- 2.281,- 2.281,- 2.281,- 2.281,- 3.589,-122 Evaporator single pump (low lift) Lei

Contact Factory123 Evaporator single pump (high lift) LeiElectrical / Control04 Dol starter Lei

Standard

10 Double setpoint Lei68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei132 Part winidng start Lei Not available06 Soft starter Lei 26.704,- 24.463,- 22.246,- 23.768,- 25.303,- 27.054,-

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)

Lei 1.787,- 1.787,- 1.787,- 1.787,- 1.787,- 1.787,-

17 Capacitors for power factor correction Lei 6.094,- 6.094,- 6.094,- 6.094,- 6.094,- 6.094,-58 Evaporator flow switch Lei 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,-59 Condenser flow switch Lei 1.029,- 1.029,- 1.029,- 1.029,- 1.029,- 1.029,-95 Compressors circuit breakers Lei 2.751,- 2.869,- 2.984,- 2.984,- 2.984,- 3.384,-102 Ground fault relay Lei 3.449,- 3.449,- 3.449,- 3.449,- 3.449,- 3.449,-Installation75 Rubber anti vibration mounts Lei 1.233,- 1.233,- 1.233,- 1.233,- 1.233,- 1.233,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Page 44: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

44

EWLQ-KBW1N ʯ One of the most compact units on the market ʯ Daikin scroll compressor ʯ Electronic DDC controller ʯ Low operating sound level ʯ Low energy consumption ʯ Low refrigerant volume ʯ Easy installation and maintenance ʯ Stainless steel plate heat exchanger ʯ Standard integrated: main switch, pressure ports, flow switch, filter, shutoff valves and air purge

Condenserless chiller

Unit size EWLQ014KBW1N EWLQ025KBW1N EWLQ033KBW1N EWLQ049KBW1N EWLQ064KBW1NPrice Lei 19.351,- 25.973,- 30.069,- 40.989,- 48.579,-Cooling capacity(1) kW 12,05 21,87 27,69 43,40 56,71EER 3,41 3,41 3,39 3,41 3,5Sound power level dB(A) 64 64 71 67 74

OptionsOPZH glycol application to -5°C LWE Lei 1.170,- 1.170,- 1.170,- 1.170,- 1.170,-OPZL glycol application to -10°C LWE Lei 1.170,- 1.170,- 1.170,- 1.170,- 1.170,-

KitEKLS1 low noise kit 5 HP Lei 1.411,- – – – –EKLS2 low noise kit 8/10/12 HP Lei – 1.366,- 1.366,- 1.366,- 1.366,-EKAC10C(2) BMS address card Lei 778,- 778,- 778,- 778,- 778,-EKRUMCA(2) remote user interface Lei 1.439,- 1.439,- 1.439,- 1.439,- 1.439,-

Notes:

(1) Cooling: Ta DB/WB 35°C - LWE 7°C ( DT = 5°C) data according EN 14511: 2011

(2) EKAC10C is needed for direct BMS connection via Modbus and to install EKRUMCA

Page 45: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 45

EWLQ-G-SSOne refrigerant circuit, standard efficiency rating

ʯ Single refrigerant circuit ( scroll compressors) with single evaporator

ʯ For chilled water production, to be combined with a remote condensing unit

ʯ Compact design to allow easy indoor installation or retrofit operations

ʯ Conceived for stacked installation of two single circuit units to reduce the footprint

ʯ High efficiency and reliable scroll compressor ʯ Stainless steel plate heat exchanger

Type of unit (rated power in accordance with EN14511) EWLQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Price Lei 74.563,- 79.540,- 84.916,- 90.637,- 95.896,- 105.217,- 113.526,- 116.092,- 124.132,- 150.168,- 171.189,-Commissioning by DAIKIN service (net price) Lei 4.550,- 4.550,- 4.550,- 4.550,- 4.550,- 4.550,- 4.550,- 4.550,- 4.550,- 4.550,- 4.550,-Cooling capacity kW 86,5 98,4 110 125 139 160 181 206 231 290 346Power input kW 22,4 25,8 29,2 33 36,8 42 47 54,2 59,9 75,6 91,8Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1Compressors 2 2 2 2 2 2 2 2 2 2 2EER 3,86 3,81 3,78 3,79 3,79 3,8 3,86 3,8 3,85 3,84 3,77Length mm 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743Width mm 928 928 928 928 928 928 928 928 928 928 928Height mm 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.186 1.186Weight of unit / Operating weight kg 494/525 578/615 686/729 714/760 742/791 773/826 807/863 838/901 852/916 967/1.044 1.046/1.134Sound power / Sound pressure (at 1m) dB(A) 80/64 83/67 85/69 87/70 88/72 88/72 88/72 90/74 92/76 93/76 93/77

Optional accessories for chiller:

Code Type of unit EWLQ-G-SS 090 100 120 130 150 170 190 210 240 300 360Mechanical20 Evaporator victaulic kit Lei

Standard 29 20mm evaporator insulation Lei60 Electronic expansion valve Lei133 Stacked installation Lei 7.490,- 7.490,- 7.490,- 7.490,- 7.490,- 7.490,- 7.490,- 7.490,- 7.490,- 7.490,- 7.490,-08 Brine version Lei 2.176,- 2.176,- 2.176,- 2.176,- 2.176,- 2.176,- 2.176,- 2.176,- 2.176,- 2.176,- 2.176,-03 Partial heat recovery Lei Not available126 Discharge and suction line shut-off valve Lei 3.620,- 3.620,- 3.620,- 3.620,- 3.620,- 3.620,- 3.620,- 3.620,- 3.620,- 3.620,- 3.620,-127 High and low pressure side manometers Lei 1.182,- 1.182,- 1.182,- 1.182,- 1.182,- 1.182,- 1.182,- 1.182,- 1.182,- 1.182,- 1.182,-76-c Sound proof system (compressors jacket) Lei 4.157,- 3.759,- 3.387,- 3.387,- 3.387,- 3.387,- 3.387,- Not available76-b Sound proof system (compressor) Lei 13.657,- 13.657,- 13.657,- 13.657,- 13.657,- 13.657,- 13.657,- 13.657,- 13.657,- 13.657,- 13.657,-91 Double pressure relief valve with diverter Lei 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,-115 Water filter Lei 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 3.570,-122 Evaporator single pump (low lift) Lei 5.293,- 5.293,- 5.637,- 5.637,- 5.637,- 9.340,- 9.340,- 9.340,- 9.340,- 9.340,- 8.671,-123 Evaporator single pump (high lift) Lei 6.083,- 6.083,- 6.476,- 6.476,- 6.476,- 10.745,- 10.745,- 10.745,- 10.745,- 10.745,- 9.972,-Electrical / Control04 Dol starter Lei Standard Not available132 Part winidng start Lei Not available Standard10 Double setpoint Lei

Standard68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei06 Soft starter Lei 12.315,- 11.218,- 10.131,- 10.857,- 11.580,- 12.429,- 13.284,- 14.123,- 14.967,- Not available

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)

Lei 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,-

17 Capacitors for power factor correction Lei 3.302,- 3.302,- 3.302,- 3.302,- 3.302,- 3.302,- 5.835,- 5.835,- 5.835,- 8.159,- 8.159,-58 Evaporator flow switch Lei 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,-95 Compressors circuit breakers Lei 1.384,- 1.440,- 1.500,- 1.500,- 1.500,- 1.694,- 1.897,- 1.970,- 2.046,- 6.956,- 11.868,-102 Ground fault relay Lei 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,-Installation75 Rubber anti vibration mounts Lei 865,- 865,- 865,- 865,- 865,- 865,- 865,- 865,- 865,- 865,- 865,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Condenserless chiller

Page 46: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

46

EWLQ-L-SS Standard efficiency rating, two refrigerant circuits

ʯ Dual refrigerant circuit ( scroll compressors) with single evaporator ʯ For chilled water production, to be combined with a remote condensing unit

ʯ Compact design to allow easy indoor installation or retrofit operations

ʯ High efficiency and reliable scroll compressor ʯ Stainless steel plate heat exchanger

Type of unit (rated power in accordance with EN14511) EWLQ-L-SS 180 205 230 260 290 330Price Lei 137.997,- 139.130,- 149.225,- 158.938,- 169.828,- 183.703,-Commissioning by DAIKIN service (net price) Lei 6.780,- 6.780,- 6.780,- 6.780,- 6.780,- 6.780,-Cooling capacity kW 173 197 224 249 279 317Power input kW 44,3 51,1 57,9 65,6 73,2 83,8Refrigerant circuit 2 2 2 2 2 2Compressors 4 4 4 4 4 4EER 3,91 3,86 3,87 3,79 3,81 3,78Length mm 2.801 2.801 2.801 2.801 2.801 2.801Width mm 928 928 928 928 928 928Height mm 1.970 1.970 1.970 1.970 1.970 1.970Weight of unit / Operating weight kg 832/894 1.007/1.081 1.202/1.292 1.252/1.345 1.333/1.436 1.380/1.486Sound power / Sound pressure (at 1m) dB(A) 83/65 86/68 88/70 90/72 91/74 91/74

Condenserless chiller

Optional accessories for chiller:

Code Type of unit EWLQ-L-SS 180 205 230 260 290 330Mechanical20 Evaporator victaulic kit Lei

Standard 29 20mm evaporator insulation Lei60 Electronic expansion valve Lei08 Brine version Lei 4.335,- 4.335,- 4.335,- 4.335,- 4.335,- 4.335,-126 Discharge and suction line shut-off valve Lei 7.255,- 7.255,- 7.255,- 7.255,- 7.255,- 7.255,-127 High and low pressure side manometers Lei 2.363,- 2.363,- 2.363,- 2.363,- 2.363,- 2.363,-76-c Sound proof system (compressors jacket) Lei 9.693,- 8.789,- 7.882,- 7.882,- 7.882,- 7.882,-76-b Sound proof system (compressor) Lei 27.312,- 27.312,- 27.312,- 27.312,- 27.312,- 27.312,-91 Double pressure relief valve with diverter Lei 6.486,- 6.486,- 6.486,- 6.486,- 6.486,- 6.486,-115 Water filter Lei 2.270,- 2.270,- 2.270,- 2.270,- 2.270,- 3.570,-122 Evaporator single pump (low lift) Lei

Contact Factory123 Evaporator single pump (high lift) LeiElectrical / Control04 Dol starter Lei

Standard

10 Double setpoint Lei68 Hour run meter Lei69 General fault contactor Lei97 Main switch interlock door Lei128 Master/Slave Lei132 Part winidng start Lei Not available06 Soft starter Lei 26.568,- 24.337,- 22.133,- 23.647,- 25.173,- 26.915,-

15aControl expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card POL965)

Lei 1.778,- 1.778,- 1.778,- 1.778,- 1.778,- 1.778,-

17 Capacitors for power factor correction Lei 6.064,- 6.064,- 6.064,- 6.064,- 6.064,- 6.064,-58 Evaporator flow switch Lei 1.023,- 1.023,- 1.023,- 1.023,- 1.023,- 1.023,-95 Compressors circuit breakers Lei 2.737,- 2.855,- 2.970,- 2.970,- 2.970,- 3.367,-102 Ground fault relay Lei 3.431,- 3.431,- 3.431,- 3.431,- 3.431,- 3.431,-Installation75 Rubber anti vibration mounts Lei 1.227,- 1.227,- 1.227,- 1.227,- 1.227,- 1.227,-Communication cards / AccessoriesEKCM200J BMS card (ModBUS-RTU) Lei 1.618,- 1.618,- 1.618,- 1.618,- 1.618,- 1.618,-EKCMBACMSTP BMS card (BacNet/ MSTP) Lei 1.938,- 1.938,- 1.938,- 1.938,- 1.938,- 1.938,-EKCMLON BMS card (LonWorks) Lei 1.889,- 1.889,- 1.889,- 1.889,- 1.889,- 1.889,-

Page 47: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 47

intelligent Chiller Manager - iCM

iCM is available in two versions:

Standard versionConfigurable controller with a pre-set library of applications. The standard system is divided into three configurations according to how many chillers and peripherals it can manage.

Customised versionFree-programmable controller for those applications not covered by the Standard version.

ICMPABICMPAL

ICMPAF

Standard Customised

(Free-programmable )(Configuration )

(Basic) (≤4 MT3 chillers)

(Customised )(Light/Full)(≤4/≤8 MT3 chillers

& peripherals)

intelligent Chiller ManageriCM Basic(1), for evaporator side managementup to 8 chiller manageable (without peripheral device) Lei

EKDICMPAB27.743,-

iCM Light(1), for evaporator side managementup to 8 chiller, up to 4 evaporator pumps, up to 4 evaporator shut-off valves, 1 bypass valve (evaporator side) manageable Lei

EKDICMPAL67.117,-

iCM Full(1), for evaporator side managementup to 8 chiller, up to 8 evaporator pumps, up to 8 evaporator shut-off valves, 1 bypass valve (evaporator side) manageable Lei

EKDICMPAF99.958,-

iCM Customisedbased on ad hoc specifications Lei on request

NEW

iCMPAB

iCMPWLiCMPWF

intelligent Chiller ManageriCM Light, for evaporator and condenser side management up to 8 chillers, up to 4 evaporator pumps and 4 condenser pumps, up to 4 evaporator and 4 condenser shut-off valves, 1 bypass valve (evaporator side), 1 bypass valve (condenser side) manageable

Lei

EKDICMPWL

on request

iCM Full, for evaporator and condenser side management up to 8 chillers, up to 8 evaporator pumps and 8 condenser pumps, up to 8 evaporator and 8 condenser shut-off valves, 1 bypass valve (evaporator side), 1 bypass valve (condenser side) manageable

Lei

EKDICMPWF

on request

Page 48: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

48

intelligent Chiller Manager - iCM

intelligent Chiller ManageriCM Basic, for evaporator side management of Daikin and Non-Daikin Chiller up to 8 chillers (up to 2 non-Daikin) manageable Lei

EKDICMPAB-IOon request

iCM Light, for evaporator side management of Daikin and Non-Daikin Chiller up to 8 chillers (up to 2 non-Daikin), up to 4 evaporator pumps, up to 4 evaporator shut-off valves, 1 bypass valve (evaporator side) manageable Lei

EKDICMPAL-IOon request

intelligent Chiller ManagerICM Light, for Cooling tower/Dry Cooler management up to 4 Cooling tower/Dry Cooler, up to 4 fan, up to 4 sump valves, up to 4 spray valves manageable Lei

EKDICMCTLon request

ICM Full, for Cooling tower/Dry Cooler management up to 4 groups of Cooling tower/Dry Cooler, up to 8 fan, up to 8 sump valves, up to 8 spray valves manageable Lei

EKDICMCTFon request

iCMPAB-IO (Basic)iCMPAL-IO (Light)

NON-Daikin Chiller

NON-Daikin Chiller

ICMCTLICMCTF

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Cooling tower/Dry cooler

Scope and type of equipment which can be controlled by iCM

Commissioning and Installation iCM(2)

iCM Basic Configuration and settings, fine tuning on site

LeiCE.S_ICM_AS_BASIC

on requestiCM Light Configuration and settings, wiring test, fine tuning on site

LeiCE.S_ICM_AS_LIGHT

on requestiCM Full Configuration and settings, wiring test, fine tuning on site

LeiCE.S_ICM_AS_FULL

on request

iCM CustomisedLei

CE.S_ICM_AS_COMon request

Notes:

(1)The iCM option is compatible for the following chiller series: EWHA~TZB, EWAD~TZB, EWAD~T- (B), EWAQ~G-, EWAQ~E (single), EWAQ~F (dual), EWAT_B (single), EWAT_B (dual),

EWAD~CZ, EWAD~CF, EW_Q-G, EW_Q-L, EWWD~G-, EWLD~G-, EWLD~I-, EWWD~J-, EWLD~J-, EWWH~VZ A , EWWD~VZ A, EWWH~DZ, EWWD~DZ, DWSC & DWDC, WTC. Daikin

chiller not in this list and non-Daikin (3rd party) chillers, can be managed by EKDICMPAB/L-IO

(2) Note that the price are net installer prices.

SpecificationChiller (Dedicated/Manifolded) ≤8

Operating mode Cooling Evaporator pumps (CSD/VFD) & (Dedicated/Manifolded)

≤8

Shut-off valves (evaporator side) ≤8

Bypass valve (evaporator side)

Condenser pumps (CSD/VFD) & (Dedicated/Manifolded)

≤8

Shut-off valves (condenser side) ≤8

Bypass valve (condenser side)

Cooling tower/Dry cooler fans (CSD/VFD) ≤(8x3)

Page 49: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 49

Low ESP duct unit FWE-C 02 03 04 06 07 08 10FWE**CT-, 2 pipe unit, standard, without valves

Lei 1.174,- 1.330,- 1.446,- 1.880,- 2.032,- 2.371,- 2.854,-

FWE**CTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

Lei 2.032,- 2.186,- 2.302,- 2.738,- 2.892,- 3.233,- 3.715,-

FWE**CTT, 2 pipe unit, with 2-ways 230V on/off valve, factory mounted

Lei 1.656,- 1.821,- 1.929,- 2.371,- 2.513,- 2.854,- 3.335,-

Cooling capacity (Total at Super High Speed)(1) kW 2,17 3,22 4,34 6,06 6,83 7,84 9,96Heating capacity (2-pipe at Super High Speed)(2) kW 2,79 4,28 5,61 7,66 9,26 10,50 13,00Airflow m³/h 430 638 910 1.195 1.559 1.753 2.177Sound power level dB(A) 51 61 58 62 62 64 65FWE**CF-, 4 pipe unit, standard, without valves

Lei 1.373,- 1.554,- 1.680,- 2.163,- 2.313,- 2.712,- 3.194,-

FWE**CFV, 4 pipe unit, with 3-ways 230V on/off valves, factory mounted

Lei 2.868,- 3.053,- 3.185,- 3.667,- 3.808,- 4.208,- 4.690,-

FWE**CFT, 4 pipe unit, with 2-ways 230V on/off valves, factory mounted

Lei 2.328,- 2.503,- 2.634,- 3.112,- 3.268,- 3.667,- 4.149,-

Cooling capacity (Total at Super High Speed)(1) kW 2,10 3,16 3,98 6,05 6,78 7,79 9,91Heating capacity (4-pipe at Super High Speed)(3) kW 2,30 3,53 4,56 6,17 7,60 8,52 10,40Airflow (High Speed) m³/h 416 626 835 1.193 1.548 1.742 2.166Sound power level (High Speed) dB(A) 51 61 58 62 62 64 65

Accessories for FWE-C 02 02 03 04 06 07 08 10

2 pipes 3-ways on/off 230V valve kit On / Off function, including piping unit

EK2MV3B10C5

Lei 492,-

2 pipes 2-ways on/off 230V valve kit On / Off function, including piping unit

EK2MV2B10C5

Lei 370,-

4 pipes 3-ways on/off 230V valve kit On / Off function, including piping unit

EK4MV3B10C5

Lei 846,-

4 pipes 2-ways on/off 230V valve kit On / Off function, including piping unit

EK4MV2B10C5

Lei 722,-

Notes:

(1) Cooling: 2/4 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB, entering water 50°C, leaving water 40°C

FWE-C AC fan motor unit for horizontal concealed mounting

ʯ 2-pipe and 4-pipe units in 7 sizes ʯ 4-speed fan motor ʯ External pressure max. 40 Pa ʯ System pressure max. 16 bar ʯ Water temperature from + 3°C to +70°C ʯ Air temperature from +10°C to +36°C ʯ Factory mounted valve (both left and right side) ʯ Condensate pump not included ʯ Water connections and electrical connections standard - left

Low ESP duct fan coil

Page 50: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

50

Medium ESP duct unit FWB-B 02 03 04 05 06 07 08 09 10FWB**BTN, 2 pipe unit, standard, without valves

Lei 2.269,- 2.410,- 2.552,- 3.092,- 3.194,- 3.492,- 4.217,- 4.455,- 4.747,-

FWB**BTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

Lei 2.985,- 3.135,- 3.277,- 3.808,- 3.925,- 4.217,- 4.982,- 5.216,- 5.511,-

FWB**BTNE, 2 pipe unit, without valves and electric heater, factory mounted

Lei 3.642,- 3.794,- 3.948,- 4.616,- 4.734,- 5.030,- 5.862,- 6.097,- 6.394,-

FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted

Lei 4.373,- 4.514,- 4.665,- 5.347,- 5.455,- 5.756,- 6.627,- 6.862,- 7.158,-

Cooling capacity (Total at High Speed)(1) kW 2,32 2,82 3,13 4,47 4,74 5,69 5,70 6,48 7,65Heating capacity (2-pipe at High Speed)(2) kW 2,54 2,80 3,00 4,70 5,15 5,56 5,95 6,57 7,18Heating capacity (4-pipe at High Speed)(3) kW 3,97 3,97 3,97 6,97 6,97 6,97 16,44 16,44 16,44Electric heater power input kW 2,0 2,0 2,0 2,5 2,5 2,5 3,0 3,0 3,0Airflow (High Speed) m³/h 371 371 371 722 722 722 905 905 905Sound power level (High Speed) dB(A) 58 58 58 60 60 60 69 69 69

Accessories for FWB-B 02 03 04 05 06 07 08 09 10

Additional single row heat exchanger max. + 95 ° C water temperature

EAH04A6 EAH07A6 EAH10A6

Lei 787,- 910,- 1.239,-

3-way valve add. h/e Actuator 230V included

E2MV307A6 E2MV310A6

Lei 812,- 812,-

2-way valve add. h/e Actuator 230V included

E2MV207A6 E2MV210A6

Lei 458,- 458,-

Fan stop thermostat Nedeed with controller FWEC1A

YFSTA6

Lei 88,-

Drain pumpCDRP1A

Lei 1.026,-Plenum box insulated with circular connections (supply side)

EPAA02A6 EPAA05A6 EPAA08A6Lei 122,- 726,- 1.054,-

Notes:

(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.

(2) Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K.

(3) Heating: 4 pipe: air 20°CDB, entering water 70°C, leaving water 60°C

FWB-B AC fan motor unit for horizontal concealed mounting

ʯ Low sound power levels and electrical absorption thanks to plastic impeller and improved electric motor

ʯ 2-pipe devices in 9 sizes ʯ 7- speed fan motor ʯ 3, 4 or 6 stage row cooling coil ʯ External pressure max. 80 Pa ʯ System pressure max. 10 bar ʯ Water temperature from + 5 ° C to + 95 ° C ʯ Air temperature from + 5 ° C to + 43 ° C ʯ Factory mounted 3-way valve ʯ Additional heating coil or factory -installed electric heater available

ʯ Condensate pump not included

Medium ESP duct fan coil

Page 51: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 51

FWE-C, FWB-B

FWE-C 02 03 04 - 06 07 08 - 10

FWB-B 02 03 04 05 06 07 08 09 10

Electronic Controller - standard version It can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit ; on/off control valve; heating/cooling function; digital input for external release or window contact

FWEC1A

Lei 506,-

Electronic Controller - advanced version 3 or 4 stages speed controller; on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol)

FWEC2A

Lei 733,-

Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3A

Lei 998,-Split type electronic controller FWECSAP+FWECSAC

FWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

Lei 757,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

Lei 571,-

Wall mounting kit (spacing collar) for FWEC1A /2A and 3A

FWFCKA

Lei 63,-

Temperature sensor kit for FWEC1A /2A and 3A; with 1.5 meters of cable

FWTSKA

Lei 63,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKA

Lei 113,-

Master/Slave interface for connection of max. 4 devices to a remote control; max. 3.2 Amp. operating current per device connection

EPIMSA6

Lei 747,-

Controller for FWE-C and FWB-B

Page 52: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

52

Medium ESP duct unit with DC fan motor FWP-A 02 03 04 05 06 07FWP**ATN, 2 pipe unit, standard, without valves

Lei 3.233,- 3.375,- 3.501,- 4.100,- 4.149,- 4.431,-

FWP**ATV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted

Lei 3.948,- 4.091,- 4.217,- 4.831,- 4.874,- 5.157,-

FWP**ATNE, 2 pipe unit, without valves and electric heater, factory mounted

Lei 4.616,- 4.757,- 4.889,- 5.639,- 5.688,- 5.971,-

FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted

Lei 5.337,- 5.477,- 5.604,- 6.369,- 6.418,- 6.695,-

Cooling capacity (Total at High Speed)(1) kW 2,38 2,88 3,19 4,58 4,85 5,8Heating capacity (2-pipe at High Speed)(2) kW 2,54 2,80 3,00 4,71 5,15 5,56Heating capacity (4-pipe at High Speed)(3) kW 3,02 3,02 3,02 5,68 5,68 5,68Electric heater power input kW 2,0 2,0 2,0 2,5 2,5 2,5Airflow (High Speed) m³/h 371 371 371 722 722 722Sound power level (High Speed) dB(A) 58 58 58 60 60 60

Accessories for FWP-A 02 03 04 05 06 07

Additional single row heat exchanger max. + 95 ° C water temperature

EAH04A6 EAH07A6

Lei 787,- 910,-

3-way valve add. h/e Actuator 230V included

E2MV307A6

Lei 812,-

2-way valve add. h/e Actuator 230V included

E2MV207A6

Lei 458,-

Drain pumpCDRP1A

Lei 1.026,-Plenum box (insulated with circular connections (supply side)

EPAA02A6 EPAA05A6Lei 122,- 726,-

Notes:

(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.

(2) Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K.

(3) Heating: 4 pipe: air 20°CDB, entering water 70°C, leaving water 60°C

FWP-A BLDC fan motor unit for horizontal concealed mounting.Continuous air flow regulation and fan speed modulation.

ʯ Low sound level and up to 50% energy saving thanks to the BLDC motor technology

ʯ 2-pipe devices in 6 sizes ʯ 3-stage fan motor ʯ External pressure max. 80 Pa ʯ System pressure max. 10 bar ʯ Water temperature from + 5 ° C to + 95 ° C ʯ Air temperature from + 5 ° C to + 43 ° C ʯ Factory mounted 3-way valve

Medium ESP duct fan coil

ʯ Additional heating coil or electric heater available ʯ Condensate pump not included

Page 53: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 53

2-pipe unit FWN**AT 04 05 06 07 08 10Price Lei 3.713,- 3.987,- 6.659,- 7.042,- 7.272,- 7.614,-Cooling capacity (Total at High Speed)(1) kW 3,91 4,76 6,17 6,81 7,83 8,75Heating capacity (2-pipe at High Speed)(2) kW 4,85 5,79 7,67 8,65 9,46 10,70

4-pipe unit FWN**AF 04 05 06 07 08 10Price Lei 4.184,- 4.567,- 7.220,- 7.574,- 7.949,- 8.396,-Cooling capacity (Total at High Speed)(1) kW 3,88 4,72 6,06 6,69 7,70 8,60Heating capacity (4-pipe at High Speed)(3) kW 4,48 4,45 6,53 6,44 9,13 9,07

Accessories for FWN-A 04 05 06 07 08 10Electric heater low capacity EDEH04A6 EDEHS06A6 EDEHS10A6Capacity kW 2,0 3,0 4,5Price Lei 1.521,- 2.631,- 2.631,-Electric heater high capacity EDEH04A6 EDEHB06A6 EDEHB10A6Capacity kW 2,0 6,0 9,0Price Lei 1.521,- 2.631,- 2.631,-

2-pipe 3-way valveActuator 230V included

ED2MV04A6 ED2MV10A6

Lei 1.126,- 1.126,-

4-pipe 3-way valveActuator 230V included

ED4MV04A6 ED4MV10A6

Lei 2.165,- 2.165,-

Vertical drainpan EDDPV10A6

Lei 88,-

Horizontal drainpan EDDPH10A6

Lei 88,-

Fresh air intake Servomotor 24V ~ Incl. Positioner 0 ... 100%

EDMFA04A6 EDMFA06A6 EDMFA10A6

Lei 5.089,- 5.153,- 5.277,-

Drain pumpCDRP1A

Lei 1.026,-

Notes:

(1) Cooling: Inlet/outlet water temperature 7/12 °C; inlet air temperature 27°C DB 19°C WB

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: Inlet/outlet water temperature 70/60 °C; inlet air temperature 20°C DB

FWN-A BLDC fan motor unit for horizontal or vertical mounting.Continuous air flow regulation and fan speed modulation

ʯ Up to 70% energy savings with brushless DC motor technology compared to traditional technology

ʯ Instant adjustment to temperature and relative humidity changes ʯ Low operating sound level ʯ Highly flexible solutions: multiple sizes, piping topologies and connection valves

ʯ Available static pressure up to 70 Pa

Medium ESP flexi type fan coil

Page 54: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

54

FWP-A, FWN-A

FWP-A 02 03 04 05 06 07

FWN-A 04 05 06 07 08 010

Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3A

Lei 998,-Split type electronic controller FWECSAP+FWECSACFWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

Lei 757,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

Lei 571,-

Wall mounting kit (spacing collar) for FWEC1A /2A and 3A

FWFCKA

Lei 63,-

Temperature sensor kit for FWEC1A /2A and 3A; with 1.5 meters of cable

FWTSKA

Lei 63,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKA

Lei 113,-

Controller for FWP-A and FWN-A

Page 55: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 55

2-pipe unit FWD**AT 04 06 08 10 12 16 18Price Lei 2.712,- 3.575,- 4.183,- 4.656,- 5.781,- 7.416,- 8.157,-Cooling capacity (Total at High Speed) (1) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30Heating capacity (2-pipe at High Speed) (2) kW 4,05 7,71 9,43 10,79 14,45 19,81 21,92Airflow m³/h 800 1.250 1.600 1.600 2.200 3.000 3.000Sound power level dB(A) 66 69 72 72 74 78 78

4-pipe unit FWD**AF 04 06 08 10 12 16 18Price Lei 3.185,- 4.159,- 4.855,- 5.380,- 6.779,- 8.590,- 9.412,-Cooling capacity (Total at High Speed) (3) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30Heating capacity (4-pipe at High Speed) (4) kW 4,49 6,62 9,21 9,21 15,86 21,15 21,15Airflow m³/h 800 1.250 1.600 1.600 2.200 3.000 3.000Sound power level dB(A) 66 69 72 72 74 78 78

Accessories for FWD-A 04 06 08 10 12 16 18

Electric heater low capacity

EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6kW 2,0 3,0 4,5 4,5 4,5 9,0 9,0Lei 1.521,- 2.631,- 2.631,- 2.631,- 2.631,- 2.971,- 2.971,-

Electric heater high capacity

EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6kW 2,0 6,0 9,0 9,0 9,0 12,0 12,0Lei 1.521,- 2.631,- 2.631,- 2.631,- 2.631,- 2.971,- 2.971,-

2-pipe 3-way valve Actuator 230V included

ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6Lei 1.126,- 1.126,- 1.126,- 1.165,-

4-pipe 3-way valve Actuator 230V included

ED4MV04A6 ED4MV10A6 2 x ED2MV12A6 2 x ED2MV18A6Lei 2.165,- 2.165,- 2.251,- 2.329,-

Vertical drainpanEDDPV10A6 EDDPV18A6

Lei 88,- 113,-

Horizontal drainpanEDDPH10A6 EDDPH18A6

Lei 88,- 113,-

Fan stop thermostat YFSTA6Lei 88,-

Fresh air intake Servomotor 24V ~ Incl. Positioner 0 ... 100%

EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6Lei 5.089,- 5.153,- 5.277,- 5.543,- 5.685,-

Drain pump CDRP1A

Lei 1.026,-

FWD-A AC fan motor unit for horizontal concealed mounting

ʯ 2 and 4-pipe devices in 7 sizes ʯ 3-stage fan motor ʯ External pressure max. 120 Pa ʯ System pressure max. 10 bar ʯ Water temperature from + 5 ° C to + 95 ° C ʯ Air temperature from + 5 ° C to + 43 ° C ʯ Factory mounted 2 or 3 way valve ʯ Condensate pump not included

High ESP flexi type fan coil

Notes:

(1) Cooling: 2 pipe: air 27ºCDB, 19ºCWB; entering water 7ºC; leaving water 12ºC at nominal air flow and ESP

(2) Heating: 2 pipe: air 20ºCDB; entering water 50ºC; water flow as in cooling mode at nominal air flow and ESP

(3) Rating conditions 4-pipe: air 27ºCDB - 19ºCWB - entering water 7ºC - leaving water 12ºC at nominal air flow and ESP

(4) Rating conditions 4-pipe:g: 4-pipe: air 20ºCDB - entering water 70ºC - leaving water 60ºC at nominal air flow and ESP

Page 56: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

56

FWD-A

Controller for FWD AT/AF

Controller for FWD 04 06 08 10 12 16 18Electronic Controller - standard version It can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit ; on/off control valve; heating/cooling function; digital input for external release or window contact

FWEC1AFWEC1A

EPIB6 requested

Lei 506,- 506,-Electronic Controller - advanced version 3 or 4 stages speed controller; on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol)

FWEC2AFWEC2A

EPIB6 requested

Lei 733,- 733,-Electronic Controller - advanced plus version 3 or 4 stages speed controller (or stepless for EC motor); on/off control valve; heating/cooling function; digital input for external release or window contact; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWEC3AFWEC3A

EPIB6 requested

Lei 998,- 998,-Split type electronic controller FWECSAP+FWECSAC

FWECSAP power control board 3 digital inputs and 1 configurable digital output; 3 analogue outputs 0-10V; Bus communication via RS485 (ModBus protocol); master/slave function up to 256 devices

FWECSAP

Lei 757,-FWECSAC control panel for remote or on board installation 3 or 4 stages speed controller; on/off or modulating control valve; heating/cooling function; digital input for external release or window contact; digital input for central heating/cooling changeover; master/slave function via RS485 (ModBus protocol); timer with weekly program and illuminated LCD

FWECSAC

Lei 571,-

Wall mounting kit (spacing collar) for FWEC 1A /2A and 3A

FWFCKALei 63,-

Temperature sensor kit for FWEC*A; with 1.5 meters of cable

FWTSKALei 63,-

Relative humidity sensor kit for FWEC2A and FWEC3A; with 1.5 meters of cable

FWHSKALei 113,-

Master/Slave interface for connection of max. 4 devices to a remote control; max. 3.2 Amp. operating current per device connection

EPIMSA6

Lei 747,-

Power interfacefor using electronic remote controller FWEC(1,2,3)A + new split controller FWECSA

–EPIB6

Lei 747,-

Notes:

For FWD size 12, 16 or 18 EPIB6 needs to be used for each FWD unit to connect to FWEC*A controllers.

If FWD size 12, 16 or 18 are used in Master/Slave application by using EPIMSA6 still EPIB6 needs to be used for each FWD to connect to EPIMSA6.

Page 57: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 57

FWF-C cassette unit 02 03 04FWF**CT, 2 pipe unit,incl. condensate pump, without valves

Lei 2.469,- 2.786,- 2.819,-

Cooling capacity (Total at High Speed)(1) kW 2,49 4,1 4,54Heating capacity (2-pipe at High Speed)(2) kW 3,52 4,69 5,28Airflow m³/h 646 680 748Sound power level dB(A) 52 54 56

FWT-C wall mounted unit 02 03 04 05 06FWT**CT, 2 pipe unit,without valves

Lei 1.597,- 1.656,- 1.904,- 2.293,- 2.455,-

Cooling capacity (Total at High Speed)(1) kW 2,43 2,7 3,31 4,54 5,28Heating capacity (2-pipe at High Speed)(2) kW 3,22 3,52 4,4 6,01 7,33Airflow m³/h 442 476 629 866 1.053Sound power level dB(A) 45 48 55 55 59

Accessories FWF-C 02 03 04Decoration panel 2-pipe(3)

Incl. wireless controller DCP600TC

Lei 806,-

Standard wired remote controlMERCA

Lei 644,-Simplified wired remote control(cooling only)

SRC-COALei 339,-

Simplified wired remote control(heating only)

SRC-HPALei 339,-

Wireless controlWRC-HPC

Lei 128,-2-pipe 3-way valveActuator 230V and assembling kit included

MCKCW2T3VNLei 733,-

FWF-C Fan coil

ʯ 2-pipe device ʯ 3-stage fan motor ʯ System pressure max. 16 bar ʯ Water temperature from + 5 ° C to + 50 ° C (2-pipe devices) ʯ Built-in high pressure drain pump with 700mm lift ʯ Infrared remote control as standard with decoration panel kit ʯ Switching group or bus communication not available

Cassette fan coils, Wall mounted fan coil

FWT-C Fan coil

ʯ 2-pipe devices in 5 sizes ʯ 3-stage fan motor ʯ Condensate pump not included ʯ 2-way or 3-way valve required (not included)

Accessories FWT-C 02 03 04 05 06

Standard wired remote controlMERCA

Lei 644,-Simplified wired remote control(cooling only)

SRC-COALei 339,-

Simplified wired remote control(heating only)

SRC-HPALei 339,-

Wireless controlWRC-HPC

Lei 128,-

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C.

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C; leaving water as per cooling GPM.

(3) Decoration panel is mandatory.

Page 58: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

58

Accessories for FWG - A(4) 05 08 11

Decoration Panel / FWG AT 2 pipes include GS02 wireless controller

DCP900BTA

Lei 836,-

Decoration Panel / FWG AF 4 pipes include GS02 wireless controller

DCP900BFA

Lei 836,-

Wired controller BRC51A61

Lei 506,-

Wireless controller Decoration panel already include

Type GS02

Lei Decoration panel already included

Valve kit 3-ways ON/OFF 230 V 2 pipe version

VKFWGA012T3V VKFWGA022T3V

Lei 610,- 659,-

Valve kit 3-ways ON/OFF 230 V 4 pipe version

VKFWGA014T3V VKFWGA024T3V

Lei 1.239,- 1.293,-

FWG - A cassette unit 05 08 11FWG**AT 2 pipe unit , incl, condensate pump, without valves

Lei 4.914,- 5.380,- 5.697,-

Cooling Capacity (Total at High Speed)(1) kW 5,90 8,80 11,75Heating Capacity (2 pipe at High Speed)(2) kW 7,10 11,20 13,70Airflow m³/h 1.053 1.512 1.800Sound power level dB(A) 46 57 59FWG**AF 4 pipe unit , incl, condensate pump, without valves

Lei 5.371,- 5.862,- 6.170,-

Cooling Capacity (Total at High Speed)(1) kW 4,40 7,20 9,00Heating Capacity (4 pipe at High Speed)(3) kW 7,65 11,20 15,65Airflow m³/h 1.053 1.512 1.800Sound power level dB(A) 46 57 59

FWG-A Cassette fan coils with DC fan motor

ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ Infrared remote control is standard with decoration panel kit ʯ High efficiency, continuous air flow regulation and fan speed modulation

ʯ 2-pipe or 4-pipe device ʯ System pressure max. 16 bar ʯ Water temperature from + 5°C to + 50°C for 2-pipe devices ʯ Water temperature from + 5°C to + 70°C for 4-pipe devices ʯ Built-in high pressure drain pump with 700mm lift ʯ Switching group or bus communication not available

Cassette fan coil

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

(4) Decoration panel is mandatory

Page 59: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 59

FWF-B cassette unit 02 03 04 05

FWF**BT, 2 pipe unit, incl. condensate pump, without valves

Lei 3.175,- 3.384,- 3.575,- 3.759,-

Cooling capacity (Total at Super High Speed)(1) kW 2,00 3,20 4,20 5,20Heating capacity (2-pipe at Super High Speed)(2) kW 2,90 4,00 5,40 6,70Airflow m³/h 468 468 660 876Sound power level dB(A) 44 44 50 55FWF**BF, 4 pipe unit, incl. condensate pump, without valves

Lei 3.452,- 3.691,- 3.856,- 4.018,-

Cooling capacity (Total at Super High Speed)(1) kW 2,00 2,70 3,50 4,50Heating capacity (4-pipe at Super High Speed)(3) kW 3,80 3,80 4,90 6,10Airflow m³/h 468 438 618 822Sound power level dB(A) 44 46 52 57

Notes: Decoration panel is mandatory, it is included with other accessories in table on page 60.(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C(2) Heating: 2 pipe: air 20°CDB; entering water 50°C(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

FWC-B cassette unit(4) 06 07 08 09FWC**BT, 2 pipe unit, incl. condensate pump, without valves

Lei 4.533,- 4.840,- 5.114,- 5.380,-

Cooling capacity (Total at Super High Speed)(1) kW 5,80 6,80 7,70 8,70Heating capacity (2-pipe at Super High Speed)(2) kW 8,00 8,90 10,60 12,10Airflow m³/h 1.062 1.236 1.518 1.776Sound power level dB(A) 43 47 53 57FWC**BF, 4 pipe unit, incl. condensate pump, without valves

Lei 5.679,- 6.064,- 6.344,- 6.617,-

Cooling capacity (Total at Super High Speed)(1) kW 5,80 6,60 7,60 8,70Heating capacity (4-pipe at Super High Speed)(3) kW 7,50 8,40 9,70 11,00Airflow m³/h 1.032 1.200 1.476 1.746Sound power level dB(A) 43 47 53 57

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

(4) Decoration panel is mandatory, it is included with other accessories in table on page 60.

FWF-B Fan coil

ʯ Compact casing (570mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles

ʯ Optional fresh air intake ʯ System pressure max. 16 bar ʯ Water temperature from + 5°C to + 50°C for 2-pipe devices ʯ Water temperature from + 5°C to + 70°C for 4-pipe devices ʯ Standard drain pump with 750mm lift increases flexibility and installation speed

ʯ Possibility to shut 1 or 2 flaps for easy installations in corners.

FWC-B Fan coil

ʯ 360° air discharge ensures uniform air flow and temperature distribution

ʯ Optional fresh air intake ʯ System pressure max. 16 bar ʯ Water temperature from + 5°C to + 50°C for 2-pipe devices ʯ Water temperature from + 5°C to + 70°C for 4-pipe devices ʯ Standard drain pump with 850mm lift ʯ Possibility to shut 1 or 2 flaps for easy installation in corners

Cassette fan coil

Page 60: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

60

FWC-B, FWF-B Accessories

Accessories for FWC-B, FWF-B

Options FWC-B FWF-B

Decoration Panel Round Flow StandardBYCQ140C

-Lei 1.323,-

Decoration Panel 4-way blow -BYFQ60B3

Lei 1.309,-

Sealing member of air discharge outletKDBHQ55C140 KDBH44BA60

Lei 533,- 664,-

Long-life filterKAFP551K160 KAFQ441BA60

Lei 514,- on request

Panel spacer -KDBQ44B60

Lei 2.486,-

Fresh air intake kitCE.KDDQ55C140 KDDQ44XA60

Lei 2.311,- 819,-

Remote Control WiredBRC315D (1)

Lei 571,- 571,-

Central remote control Up to 64 groups can be controlled with a maximum of 128 devices per group

DCS302C51 (2)

Lei 8.837,- 8.837,-

Electrical box with earth terminal (3 blocks)

KJB311A

Lei 408,- 408,-

Unified on/off control Up to 16 device groups can be controlled; operating indication given by LED

DCS301B51 (5)

Lei 3.711,- 3.711,-

Electrical box with earth terminal (2 blocks)

KJB212A

Lei 391,- 391,-

Schedule timer 2 programmable on/off times per day; power reserve 48 hours

DST301B51 (5)(8)

Lei 4.651,- 4.651,-Wiring adapter for electrical appendices 1 Additional board for external control and monitoring; on/off; operating and fault message; setpoint specification via 0 ... 140 Ohm signal for entire F1 / F2 line.

KRP2A52 (4)(8)

Lei 1.725,- 1.725,-Wiring adapter for electrical appendices 2Additional board for external control and monitoring; on/off; operating and fault message; setpoint specification via 0 ... 140 ohm Signal for a P1 / P2 line.

KRP4A53 (4)(8)

Lei 916,- 916,-

Remote control Infrared H/PBRC7F532F (11) BRC7E530 (11)

Lei 953,- 929,-

Remote control Infrared C/OBRC7F533F (11) BRC7E531 (11)

Lei 633,- 1.483,-

Page 61: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 61

FWC-B, FWF-B Accessories

Accessories for FWC-B, FWF-B

Options FWC-B FWF-B

Installation box for adapter PCBKRP1H98A (9) KRP1BA101 (9)

Lei 272,- 348,-

Remote Sensor with 12 meters of cable

KRCS01-4 KRCS01-1

Lei 441,- 441,-

Intelligent touch controller Up to 2 device groups can be controlled with a maximum of 64 devices per group

DCS601C51 (3)(7)

Lei 10.427,-

Electrical installation boxKJB411A

Lei 700,-

Optional PCB for MOD-bus connectionEKFCMBCB (4)(8)

Lei 467,-

2-way valve - On/Off Actuator 230V and piping unit included

EKMV2C09B (4)(6)(10)

Lei 393,-

3-way valve - On/Off Actuator 230V and piping unit included

EKMV3C09B (4)(6)(10)

Lei 442,-

Valve control PCBEKRP1C11

Lei 407,-

Remote “On/Off” and “forced off” kit -EKRORO (12)

Lei 134,-Modbus Interface for monitoring and control Universal control adapter provides external control/monitoring via 0-10 kΩ resistor or 0-10VDC input signals or floating contacts; operating or defrost signal, fault message as well as an interface to the Modbus protocol is possible; connection to P1 / P2 terminals (max 16 indoor units); a BRC remote control can be additionally connected

RTD-10

Lei 1.798,-Modbus Interface for monitoring and control Modbus Adapter provides a communication interface to the Modbus protocol P1/P2 (maximum 16 internal devices); all indoor units are controlled simultaneously, monitoring is done individually per unit; a BRC remote control can be additionally connected

RTD-NET

Lei 1.352,-

Modbus Interface DIII External control via the building management system; connection to maximum 64 devices

EKMBDXA

Lei 13.595,-

Notes:

1. Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall.2. Requires electrical installation box with earth terminal KJB311A.3. Requires electrical installation box KJB411A.4. Requires installation box KRP1H98A for FWC-B and KRP1BA101 for FWF-B.5. Requires electrical installation box with earth terminal KJB212A, if built in the wall.6. Requires valve control PCB EKRP1C11.7. I-touch:

• Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible.

8. Only 1 of these 4 options can be installed on 1 indoor unit.9. FWC -B: Max. 1 KRP1H98A box can be mounted on the unit.

Max. 2 PCB’s can be mounted in 1 KRP1H98A box. FWF-B: Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1 PCB can be mounted in 1 KRP1BA101 box.

10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98A + 1 x valve control PCB EKRP1C11 FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98A + 1 x valve control PCB EKRP1C11

FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11.11. It is possible to change the operation mode, but this will not have an impact on

the water temperature. (No feed back to water source) It is not possible to select the “auto air flow” setting. Dry operation can be selected with this remote control, but this function is not available on the FWC-B / FWF-B model.

12. This option is needed to create T1 T2 wire.

All options are supplied as kit.

Page 62: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

62

Floor standing fan coil

FWV-D AC fan motor unit for vertical mounting

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ 3-stage fan motor ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard - right ʯ Valve packages are insulated, no extra drain pan required

Low Wall unit FWV 01 15 02 25 03 35 04 06 08 10FWV**DTN, 2 pipe unit, standard, without valve

Lei 1.514,- 1.572,- 1.670,- 1.787,- 1.831,- 2.010,- 2.103,- 2.279,- 3.019,- 3.432,-

FWV**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

Lei 2.562,- 2.634,- 2.712,- 2.834,- 2.892,- 3.069,- 3.185,- 3.361,- 4.193,- 4.607,-

FWV**DATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

Lei 2.054,- 2.112,- 2.211,- 2.328,- 2.371,- 2.552,- 2.678,- 2.854,- 3.618,- 4.032,-

Cooling capacity (Total)(1) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02Heating capacity (2-pipe at High Speed)(2) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03Airflow m³/h 319 344 344 442 442 640 706 785 1.011 1.393Sound power level dB(A) 47 49 50 48 48 52 53 56 61 67FWV**DFN, 4 pipe unit,standard, without valves

Lei 1.753,- 1.831,- 1.914,- 2.054,- 2.129,- 2.293,- 2.469,- 2.654,- 3.467,- 3.866,-

FWV**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

Lei 3.642,- 3.735,- 3.817,- 3.948,- 4.032,- 4.193,- 4.373,- 4.548,- 5.464,- 5.878,-

FWV**DAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

Lei 2.834,- 2.927,- 2.995,- 3.135,- 3.209,- 3.384,- 3.609,- 3.784,- 4.656,- 5.064,-

Cooling capacity (Total) (1) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88Heating capacity (4-pipe at High Speed)(3) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35Airflow m³/h 307 330 327 432 431 628 690 763 998 1.362Sound power level dB(A) 45 79 50 48 47 51 56 59 60 66

Factory mounted options 01 15 02 25 03 35 04 06 08 103-way on/off 24V valve Lei on request3-way proportional on/off valves Lei on request2-way on/off 230V valve Lei on request2-way on/off 24V valves Lei on request2-way proportional on/off valve Lei on request4-rows coil (for 2 pipe unit only) Lei on request6-speeds fan motor Lei - on request - on r.Electric heater (for 2 pipe unit only) Lei on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10FWEC1A Standard version Lei on requestFWEC2A Advanced version Lei on requestFWEC3A Advanced Plus version Lei on requestFWECSAP Power control board Lei on request

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB; entering water 50°C; water flow rate as during cooling

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 65.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary for proportional valve.

Cooling capacity is related to High Speed, standard unit.

Page 63: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 63

Flexi type fan coil

FWL-D AC fan motor unit for horizontal or vertical mounting

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ 3-stage fan motor ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard – right ʯ Valve packages are insulated, no extra drain pan required

Flexible unit FWL 01 15 02 25 03 35 04 06 08 10FWL**DTN, 2 pipe unit,standard, without valve

Lei 1.587,- 1.670,- 1.772,- 1.846,- 1.962,- 2.112,- 2.231,- 2.395,- 3.233,- 3.652,-

FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

Lei 2.619,- 2.703,- 2.795,- 2.878,- 2.995,- 3.161,- 3.302,- 3.467,- 4.382,- 4.806,-

FWL**DATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

Lei 2.112,- 2.196,- 2.302,- 2.386,- 2.503,- 2.654,- 2.795,- 2.961,- 3.817,- 4.231,-

Cooling capacity (Total)(1) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02Heating capacity (2-pipe at High Speed)(2) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03Airflow m³/h 319 344 344 442 442 640 706 785 1.011 1.393Sound power level dB(A) 47 49 50 48 48 52 53 56 61 67FWL**DFN, 4 pipe unit,standard, without valves

Lei 1.846,- 1.939,- 1.996,- 2.152,- 2.231,- 2.469,- 2.595,- 2.771,- 3.691,- 4.091,-

FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

Lei 3.715,- 3.794,- 3.866,- 4.018,- 4.100,- 4.334,- 4.465,- 4.632,- 5.654,- 6.052,-

FWL**DAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

Lei 2.911,- 2.995,- 3.069,- 3.219,- 3.302,- 3.535,- 3.715,- 3.891,- 4.855,- 5.254,-

Cooling capacity (Total)(1) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88Heating capacity (4-pipe at High Speed)(3) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35Airflow m³/h 307 330 327 432 431 628 690 763 998 1.362Sound power level dB(A) 45 49 50 48 47 51 56 59 60 66

Factory mounted options 01 15 02 25 03 35 04 06 08 103-way on/off 24V valve Lei on request3-way proportional on/off valves Lei on request2-way on/off 230V valve Lei on request2-way on/off 24V valves Lei on request2-way proportional on/off valve Lei on request4-rows coil (for 2 pipe unit only) Lei on request6-speeds fan motor Lei - on request - on r.Electric heater (for 2 pipe unit only) Lei on request

Factory mounted options 01 15 02 25 03 35 04 06 08 10FWEC1A Standard version Lei on requestFWEC2A Advanced version Lei on requestFWEC3A Advanced Plus version Lei on requestFWECSAP Power control board Lei on request

Notes:

(1) Cooling: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating 2 pipe: air 20°C DB - entering water 50°C - water flow as in cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 65.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary for proportional valve.

Cooling capacity is related to High Speed, standard unit.

Page 64: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

64

FWM-D AC fan motor unit for horizontal or vertical concealedmounting

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ 3-stage fan motor ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard – right ʯ Valve packages are insulated, no extra drain pan required

Flexible concealed unit FWM 01 15 02 25 03 35 04 06 08 10FWM**DTN, 2 pipe unit, standard, without valve

Lei 1.280,- 1.364,- 1.413,- 1.514,- 1.563,- 1.680,- 1.753,- 1.914,- 2.528,- 2.868,-

FWM**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

Lei 2.328,- 2.410,- 2.455,- 2.562,- 2.610,- 2.752,- 2.834,- 3.009,- 3.701,- 4.041,-

FWM**DATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

Lei 1.821,- 1.904,- 1.953,- 2.054,- 2.103,- 2.221,- 2.328,- 2.493,- 3.126,- 3.467,-

Cooling capacity (Total)(1) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02Heating capacity (2-pipe at High Speed)(2) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03Airflow m³/h 319 344 344 442 442 640 706 785 1.011 1.393Sound power level dB(A) 47 49 50 48 48 52 53 56 61 67FWM**DFN, 4 pipe unit, standard, without valves

Lei 1.529,- 1.597,- 1.646,- 1.796,- 1.855,- 2.010,- 2.129,- 2.279,- 2.976,- 3.326,-

FWM**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

Lei 3.432,- 3.501,- 3.550,- 3.701,- 3.749,- 3.901,- 4.032,- 4.172,- 4.982,- 5.337,-

FWM**DAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

Lei 2.610,- 2.678,- 2.738,- 2.892,- 2.936,- 3.092,- 3.268,- 3.409,- 4.159,- 4.514,-

Cooling capacity (Total) (1) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88Heating capacity (4-pipe at High Speed)(3) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35Airflow m³/h 307 330 327 432 431 628 690 763 998 1.362Sound power level dB(A) 45 49 50 48 47 51 56 59 60 66

Factory mounted options 01 15 02 25 03 35 04 06 08 103-way on/off 24V valve Lei on request3-way proportional on/off valves Lei on request2-way on/off 230V valve Lei on request2-way on/off 24V valves Lei on request2-way proportional on/off valve Lei on request4-rows coil (for 2 pipe unit only) Lei on request6-speeds fan motor Lei - on request - on r.Electric heater (for 2 pipe unit only) Lei on requestFWECSAP - power control board Lei on request

Notes:

(1) Cooling: air 27°CDB, 19ºCWB; entering water 7°C; leaving water 12°C

(2) Heating 2 pipe: air 20°C DB - entering water 50°C - water flow as in cooling mode

(3 Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 65.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary for proportional valve.

Cooling capacity is related to High Speed, standard unit.

Concealed flexi type fan coil

Page 65: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 65

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10

Additional heat exchanger

The one-row heat exchanger is made of copper pipes and aluminum fins. Supplied as kit: 1) heat exchanger 2) fixing plate 3) self-tapping screws

ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6

Lei 330,- 393,- 433,- 571,-

Electric Heater

Kit contains: 1/ EEH Electric heater tape 2/ E box = elec. wiring and operating relays 3/ Set of heat-resistant plastic grilles (std grills need to be replaced)

Unit HeaterPower

consumptionOperting current

kw AFW01+15 EEH01 1,0 4,5FW02+25 EEH02 1,5 6,8FW03+35 EEH03 1,6 7,3FW04+06 EEH06 2,0 9,1FW08+10 EEH10 3,0 13,6

EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6

Lei 1.328,- 1.328,- 1.407,- 1.495,- 1.543,-

2-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2MV03A6 E2MV06A6 E2MV10A6

Lei 1.062,- 1.062,- 1.126,-

4-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4MV03A6 E4MV06A6 E4MV10A6

Lei 1.922,- 1.922,- 2.027,-

2-ways 230V on/off valve kit on cooling heat exchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6 E2MV2B10A6

Lei 458,- 458,-

2-ways 230V on/off valve kit on additional heat exchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷10 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6

Lei 458,-

2-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MVD03A6 E2MVD06A6 E2MVD10A6

Lei 620,- 634,- 644,-

4-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E4MVD03A6 E4MVD06A6 E4MVD10A6

Lei 1.151,- 1.176,- 1.190,-

2-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2M2V03A6 E2M2V06A6 E2M2V10A6

Lei 1.062,- 1.062,- 1.126,-

Page 66: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

66

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10

4-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4M2V03A6 E4M2V06A6 E4M2V10A6

Lei 1.922,- 1.922,- 2.027,-

2-pipe 3-ways proportional valve kit

Kit contains: 1/ 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2MPV03A6 E2MPV06A6 E2MPV10A6

Lei 1.697,- 1.657,- 1.707,-

4-pipe 3-ways proportional valve kit

Kit contains: 1/ 2 pcs 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8) 2/ 2 pcs Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4MPV03A6 E4MPV06A6 E4MPV10A6

Lei 3.103,- 3.128,- 3.152,-

2-ways 24V on/off valve kit on cooling heat exchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6 E2M2V210A6

Lei 458,- 458,-

2-ways 24V on/off valve kit on additional heat exchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷10 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6

Lei 458,-

2-ways proportional valve kit on cooling heat exchanger

Kit contains: 1/ 2way Valve Body SIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MPV207A6 E2MPV210A6

Lei 1.176,- 1.176,-

2-ways proportional valve kit on additional heat exchanger

Kit contains: 1/2way Valve Body SIZE 1÷10 valve = 1/2” (kvs=1,7) 2/ Electronic valve actuator Proportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MPV207A6

Lei 1.176,-

Fan stop thermostat

To prevent ventilating cold air during the heating stage If the water temperature inside the heat exchanger is lower than 42°C. (The bracket to fix fan stop thermostat is included in the kit.) Only required in combination with electromechanical controller

YFSTA6

Lei 88,-

Air intake & discharge grille

S: Back suction grille fixed fins, made of anodised aluminium complete with filter and galvanised steel plate subframe and recyclable acrylic fibre air filter.D: Discharge grille with double row of anodised aluminium swinging fins, complete with galvanised steel plate subframe.

EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6

Lei 910,- 1.101,- 1.431,- 1.697,-

Page 67: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 67

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10

Supporting feet

Kit contains:

ESFV ESFVG FWV FWM

2 2

2 2 -

0 1 -

4,2 x 13 mm 4 8 2,9 x 9,5 mm 4 4

ESFV06A6 ESFV10A6

Lei 113,- 113,-

Supporting feet & grille

ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6

Lei 162,- 201,- 226,- 315,-

Fresh air intake

To prevent the water from freezing inside the heat exchanger during winter. Close the outdoor air inlet louvre when the system is not operational or use an anti-freeze solution.

EFA02A6 EFA03A6 EFA06A6 EFA10A6

Lei 393,- 433,- 482,- 531,-

Rear panel

It is supplied for installation of units, in case rear side can be seen (example: installation at the back of glass windows). Unit, in case of rear panel installation, can not be fixed to wall. Kit consists of: 1. rear upper closing panel 2. rear lower closing panel 3. screws

ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6

Lei 201,- 217,- 266,- 330,-

Plenum box with circular connections (only for FWM-D)

Unit size Plenum box Ø [mm] x nSize 01-02 EPCC02A6 180 x 2Size 25-03 EPCC03A6 180 x 2Size 35-06 EPCC06A6 180 x 3Size 08-10 EPCC10A6 180 x 4

EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6

Lei 467,- 521,- 659,- 900,-

Vertical auxiliary drainpan

Install it to collect condensation. Used for vertical FCUs

EDPVB6

Lei 40,-

Horizontal auxiliary drainpan

Install it to collect condensation. Used for horizontal FCUs

EDPHB6

Lei 40,-

Controller electro-mechanical, Built in

For installation on board the unit is used for: Manually changing the operation fan speed of the unit; Automatically setting the room temperature by operating the motor-ventilator of the unit, both during cooling and heating. - 4 position rotary speed selector switch

(three speeds + stop)- Cooling/Heating operation selector - Manual set thermostat

ECFWMB6

Lei 209,-

Wired remote controller, Standard version

Onboard or wall mounted installation: - Management of AC 3-speeds fan motor

(on/off and automatic speed change)- Management of on/off valve - Management of electric heater - Cooling / heating mode swithcing based

on air / water temperature- Clean contact for remote activation (e.g.

window contact, remote on/off)

FWEC1A

Lei 506,-

Wired remote controller, Advanced version

All functionality of FWEC1A, but additionally: - Management of AC 4-speeds fan motor

(on/off and automatic speed change)- Air relative humidity control - Master & Slave System on serial RS485

(Modbus communication protocol)- Integration in BMS

FWEC2A

Lei 733,-

Wired remote controller, Advanced Plus version

All functionality of FWEC2A, but additionally: - Management of BLDC fan motor - Management of proportional valve - Weekly timer programmed operating

mode- Configurable digital outputs

FWEC3A

Lei 998,-

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Page 68: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

68

Accessories for FWV - FWL - FWM

FWV – FWL – FWMAccessories

Accessories for FWV/FWL/FWM 01 15 02 25 03 35 04 06 08 10

Split typecontroller

Power control boardFWECSAP

Lei 757,-Control panel for remote or on board installation (connected to the power control board) All functionality of FWEC3A, but additionally: - Master & Slave System on Conveyed

Waves (CW)

FWECSAC

Lei 571,-

On board mounting kit, for FWEC*A, remote airprobe incl.

To install FWEC1/2/3A thermostat on board. (left or right side) Use it only for FWV / FWZ or FWL / FWR

Side doors on left & right side

ControllersOptional

Low wall unit Flexi type

FWECKA

Lei 88,-

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

FWFCKA

Lei 63,-

Temperature sensor kit, for FWEC*A

FWTSK sensor should be connected to the FWEC*A remote control using the supplied cable as accessory and, in case of prolongations, a shielded cable only. The sensor cable (1,5 m) can be cut to measure if necessary. Sensor must be positioned on the heat exchanger OR at the valve inlet (with or without vlave installation)

FWTSKA

Lei 63,-

Relative humidity sensor kit , for FWEC2A and FWEC3A (tempereture sensor kit is required)

Bound together the air temperature remote probe, the installation of the humidity remote probe allows: - To display on the controller the

environment humidity - To select the Dehumidification function

The dehumidification function, available only in the cooling mode, uses the terminal to reduce the environmental humidity by approximately 10% compared to the humidity present at the moment of function selection.

FWHSKA

Lei 113,-

Master / Slave interface

The EPIMSA6 Master/slave interface is used for connecting up to 4 units in parallel to one controller FWEC(1,2,3)A. With the new split controller FWECSA to connect more unit you don’t need EPIMSA6 with a saving in the installation time/cost. The capacity of the EPIMSA6 contacts is max 4 x 3 A.

EPIMSA6

Lei 747,-

Drain pump For FWL only vertical installation CDRP1A

Lei 1.026,-

Page 69: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 69

Floor standing fan coil

FWZ-AFan coil with DC fan motor

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Water connections standard - left ʯ Electrical connections standard – right

Low Wall unit with DC fan motor FWZ 02 03 06 08FWZ**ATN, 2 pipe unit, standard, without valve

Lei 2.503,- 2.645,- 3.069,- 3.833,-

FWZ**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

Lei 3.535,- 3.676,- 4.125,- 4.982,-

FWZ**AATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

Lei 3.034,- 3.185,- 3.632,- 4.417,-

Cooling capacity (Total)(1) kW 2,64 4,96 6,32 10,08Heating capacity (2-pipe at High Speed)(2) kW 3,47 6,40 7,51 11,18Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71FWZ**AFN, 4 pipe unit, standard, without valves

Lei 2.726,- 2.902,- 3.432,- 4.217,-

FWZ**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

Lei 4.598,- 4.757,- 5.298,- 6.179,-

FWZ**AAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

Lei 3.794,- 3.958,- 4.548,- 5.380,-

Cooling capacity (Total)(1) kW 2,43 4,96 6,32 10,08Heating capacity (4-pipe at High Speed)(3) kW 2,46 4,19 6,45 10,06Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71

Factory mounted options 02 03 06 083-way on/off 24V valve Lei on request2-way on/off 230V valve Lei on request2-way on/off 24V valves Lei on request4-rows coil (for 2 pipe unit only) Lei on requestElectric heater (for 2 pipe unit only) Lei on request

Factory mounted options 02 03 06 08FWEC3A Advanced Plus version Lei on requestFWECSAP power control board Lei on request

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 72..

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary to control DC fan motor.

Cooling capacity is related to High Speed, standard unit.

Page 70: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

70

Flexi type fan coil

FWR-AFan coil with DC fan motor

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ For wall or ceiling mounted installation: ideal solution for spaces with no false ceilings

ʯ Instant adjustment to temperature and relative humidity changes ʯ Water connections standard - left ʯ Electrical connections standard – right

FLEXI type unit with DC fan motor FWR 02 03 06 08FWR**ATN, 2 pipe unit, standard, without valve

Lei 2.610,- 2.834,- 3.268,- 4.172,-

FWR**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

Lei 3.642,- 3.866,- 4.334,- 5.322,-

FWR**AATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

Lei 3.151,- 3.361,- 3.833,- 4.757,-

Cooling capacity (Total)(1) kW 2,64 4,96 6,32 10,08Heating capacity (2-pipe at High Speed)(2) kW 3,47 6,40 7,51 11,18Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71FWR**AFN, 4 pipe unit, standard, without valves

Lei 2.868,- 3.078,- 3.618,- 4.607,-

FWR**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

Lei 4.723,- 4.948,- 5.489,- 6.569,-

FWR**AAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

Lei 3.925,- 4.149,- 4.734,- 5.769,-

Cooling capacity (Total)(1) kW 2,43 4,96 6,32 10,08Heating capacity (4-pipe at High Speed)(3) kW 2,46 4,19 6,45 10,06Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71

Factory mounted options 02 03 06 083-way on/off 24V valve Lei on request2-way on/off 230V valve Lei on request2-way on/off 24V valves Lei on request4-rows coil (for 2 pipe unit only) Lei on requestElectric heater (for 2 pipe unit only) Lei on request

Factory mounted options 02 03 06 08FWEC3A Advanced Plus version Lei on requestFWECSAP power control board Lei on request

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included on page 72.

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary to control DC fan motor.

Cooling capacity is related to High Speed, standard unit.

Page 71: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 71

FWS-AFan coil with DC fan motorl

ʯ 2-pipe and 4-pipe devices in 10 sizes ʯ Low sound level and up to 70% energy saving thanks to the BLDC motor technology

ʯ System pressure max. 10 bar ʯ Water temperature from + 5°C to + 95°C ʯ Factory mounted 3 way valve ʯ Condensate pump not included ʯ Continuous air flow regulation and fan speed modulation ʯ Instant adjustment to temperature and relative humidity changes ʯ Water connections standard - left ʯ Electrical connections standard – right

Concealed flexi type fan coil

FLEXI type unit with DC fan motor FWS 02 03 06 08FWS**ATN, 2 pipe unit, standard, without valve

Lei 2.245,- 2.395,- 2.752,- 3.432,-

FWS**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted

Lei 3.277,- 3.418,- 3.817,- 4.581,-

FWS**AATD6V3---, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted

Lei 2.771,- 2.927,- 3.316,- 4.018,-

Cooling capacity (Total)(1) kW 2,64 4,96 6,32 10,08Heating capacity (2-pipe at High Speed)(2) kW 3,47 6,40 7,51 11,18Airflow m³/h 560 900 1200 1660Sound power level dB(A) 62 70 64 71FWS**AFN, 4 pipe unit,standard, without valves

Lei 2.479,- 2.693,- 3.078,- 3.856,-

FWS**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted

Lei 4.334,- 4.548,- 4.948,- 5.814,-

FWS**AAFD6V3---, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted

Lei 3.535,- 3.749,- 4.193,- 5.017,-

Cooling capacity (Total)(1) kW 2,43 4,96 6,32 10,08Heating capacity (4-pipe at High Speed)(3) kW 2,46 4,19 6,45 10,06Airflow m³/h 560 900 1.200 1.660Sound power level dB(A) 62 70 64 71

Factory mounted options 02 03 06 083-way on/off 24V valve Lei on request2-way on/off 230V valve Lei on request2-way on/off 24V valves Lei on request4-rows coil (for 2 pipe unit only) Lei on requestElectric heater (for 2 pipe unit only) Lei on request

Factory mounted options 02 03 06 08FWEC3A Advanced Plus version Lei on requestFWECSAP power control board Lei on request

Notes:

(1) Cooling: 2 pipe: air 27°CDB, 19°CWB; entering water 7°C; leaving water 12°C

(2) Heating: 2 pipe: air 20°CDB, entering water 50°C, water flow as per cooling mode

(3) Heating: 4 pipe: air 20°CDB; entering water 70°C; leaving water 60°C

Accessories as kits are included onpage 72..

Additional single row h/e (4-row coil) can not be used in combination with electric heater.

Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve.

Controller FWEC3A is necessary to control DC fan motor.

Cooling capacity is related to High Speed, standard unit.

Page 72: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

72

Accessories for FWZ - FWR - FWS

FWZ - FWR - FWSAccessories

Accessories for FWZ/FWR/FWS 02 03 06 08

Additional heat exchanger

The one-row heat exchanger is made of copper pipes and aluminum fins. Supplied as kit: 1) heat exchanger 2) fixing plate 3) self-tapping screws

ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6

Lei 330,- 393,- 433,- 571,-

Electric heater

Kit contains: 1/ EEH Electric heater tape 2/ E box = elec. wiring and operating relays 3/ Set of heat-resistant plastic grilles (std grills need to be replaced)

Unit HeaterPower

consumptionOperting current

kw AFW02 EEH02 1,5 6,8FW03 EEH03 1,6 7,3FW06 EEH06 2,0 9,1FW08 EEH10 3,0 13,6

EEH02A6 EEH03A6 EEH06A6 EEH10A6

Lei 1.328,- 1.407,- 1.495,- 1.543,-

2-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2MV03A6 E2MV06A6 E2MV10A6

Lei 1.062,- 1.062,- 1.126,-

4-pipe 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4MV03A6 E4MV06A6 E4MV10A6

Lei 1.922,- 1.922,- 2.027,-

2-ways 230V on/off valve kit cooling h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6 E2MV2B10A6

Lei 458,- 458,-

2-ways 230V on/off valve kit additional h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷8 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MV2B07A6

Lei 458,-

2-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2MVD03A6 E2MVD06A6 E2MVD10A6

Lei 620,- 634,- 644,-

4-pipe simplified 3-ways 230V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E4MVD03A6 E4MVD06A6 E4MVD10A6

Lei 1.151,- 1.176,- 1.190,-

2-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 2pcs of lockshield valve

E2M2V03A6 E2M2V06A6 E2M2V10A6

Lei 1.062,- 1.062,- 1.126,-

Page 73: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 73

Accessories for FWZ - FWR - FWS

FWZ - FWR - FWSAccessories

Accessories for FWZ/FWR/FWS 02 03 06 08

4-pipe 3-ways 24V on/off valve kit

Kit contains: 1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8) 2/ 2 pcs of Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ Thermal insulation on pipes and valve 4/ 4pcs of lockshield valve

E4M2V03A6 E4M2V06A6 E4M2V10A6

Lei 1.922,- 1.922,- 2.027,-

2-ways 24V on/off valve kit cooling h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6 E2M2V210A6

Lei 458,- 458,-

2-ways 24V on/off valve kit additional h/e

Kit contains: 1/ 2way Valve Body SIZE 2÷8 valve = 1/2” (kvs=1,7) 2/ Electrothermal actuator ON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed) 3/ without thermal insulation 4/ NO lockshield /shut of valve in the kit

E2M2V207A6

Lei 458,-

Air intake & discharge grille

S: Back suction grille fixed fins, made of anodised aluminium complete with filter and galvanised steel plate subframe and recyclable acrylic fibre air filter.D: Discharge grille with double row of anodised aluminium swinging fins, complete with galvanised steel plate subframe.

EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6

Lei 910,- 1.101,- 1.431,- 1.697,-

Supporting feet

Kit contains:

ESFV ESFVG FWZ FWS

2 2

2 2 -

0 1 -

4,2 x 13 mm 4 8 2,9 x 9,5 mm 4 4

ESFV06A6 ESFV10A6

Lei 113,- 113,-

Supporting feet & grille

ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6

Lei 162,- 201,- 226,- 315,-

Fresh air intake

To prevent the water from freezing inside the heat exchanger during winter. Close the outdoor air inlet louvre when the system is not operational or use an anti-freeze solution.

EFA02A6 EFA03A6 EFA06A6 EFA10A6

Lei 393,- 433,- 482,- 531,-

Rear panel

It is supplied for installation of units, in case rear side can be seen (example: installation at the back of glass windows). Unit, in case of rear panel installation, can not be fixed to wall. Kit consists of: 1. rear upper closing panel 2. rear lower closing panel 3. screws

ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6

Lei 201,- 217,- 266,- 330,-

Plenum box with circular connections (only for FWS-A)

Unit size Plenum box Ø [mm] x nSize 02 EPCC02A6 180 x 2Size 03 EPCC03A6 180 x 2Size 06 EPCC06A6 180 x 3Size 08 EPCC10A6 180 x 4

EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6

Lei 467,- 521,- 659,- 900,-

Vertical auxiliary drainpan

Install it to collect condensationcondensation. Used for vertical FCUs

EDPVB6

Lei 40,-

Horizontal auxiliary drainpan

Install it to collect condensation. Used for horizontal FCUs

EDPHB6

Lei 40,-

Page 74: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

74

Accessories for FWZ - FWR - FWS

FWZ - FWR - FWSAccessories

Accessories for FWZ/FWR/FWS 02 03 06 08

Wired remote controller, Advanced Plus version

All functionality of FWEC1A/2A (see page 51), but additionally: - Management of BLDC fan motor - Management of proportional valve - Weekly timer programmed operating

mode- Configurable digital outputs

FWEC3A

Lei 998,-

Split typecontroller

Power control boardFWECSAP

LeiControl panel for remote or on board installation (connected to the power control board) All functionality of FWEC3A, but additionally: - Master & Slave System on Conveyed

Waves (CW)

FWECSAC

Lei 571,-

On board mounting kit, for FWEC*A, remote airprobe incl.

To install FWEC1/2/3A thermostat on board. (left or right side) Use it only for FWV / FWZ or FWL / FWR

Side doors on left & right side

ControllersOptional

Low wall unit Flexi type

FWECKA

Lei 88,-

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

Wall mounting kit (spacing collar), for FWEC 1A /2A and 3A

FWFCKA

Lei 63,-

Temperature sensor kit, for FWEC*A

FWTSK sensor should be connected to the FWEC*A remote control using the supplied cable as accessory and, in case of prolongations, a shielded cable only. The sensor cable (1.5 m) can be cut to measure if necessary. Sensor must be positioned on the heat exchanger OR at the valve inlet (with or without vlave installation)

FWTSKA

Lei 63,-

Relative humidity sensor kit , for FWEC2A and FWEC3A (tempereture sensor kit is required)

Bound together the air temperature remote probe, the installation of the humidity remote probe allows: - To display on the controller the

environment humidity - To select the Dehumidification function

The dehumidification function, available only in the cooling mode, uses the terminal to reduce the environmental humidity by approximately 10% compared to the humidity present at the moment of function selection.

FWHSKA

Lei 113,-

Drain pump For FWR only vertical installation CDRP1A

Lei 1.026,-

Page 75: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 75

ERQ Inverter heat pump condensing unitsERQ-A

High efficiency inverter heat pump outdoor units for connection to DX heat exchangers in Air Handling Units (AHU) or to CYQ Air Curtains

Outdoor units

Type for 1~ 230V power supply ERQ100AV1 ERQ125AV1 ERQ140AV1Capacity index 100 125 140Nominal cooling capacity kW 11,2 14,0 15,5Nominal heating capacity kW 12,5 16,0 18,0Price Lei 15.181,- 16.530,- 21.251,-

Type for 3N~ 400V power supply ERQ125AW1 ERQ200AW1 ERQ250AW1Capacity index 125 200 250Nominal cooling capacity kW 14,0 22,4 28,0Nominal heating capacity kW 16,0 25,0 31,5Price Lei 18.977,- 26.358,- 30.738,-

Notes: - When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K,

on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)

Expansion valve kitAllowed heat exchanger capacity [kW] Combinable units

Price LeiMinimum Maximum ERQ100- ERQ125- ERQ140- ERQ200- ERQ250-

EKEXV63 6,3 7,8 • • 849,-EKEXV80 7,9 9,9 • • • 892,-EKEXV100 10,0 12,3 • • • • 931,-EKEXV125 12,4 15,4 • • • • • 984,-EKEXV140 15,5 17,6 • • • • 1.013,-EKEXV200 17,7 24,6 • • 1.104,-EKEXV250 24,7 30,8 • • 1.173,-

Notes: - An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains,- The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger,- The AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0,3 and 8,3 l (not counting headers and distributors)- Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K, on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating)

Unit-specific Accessories

EKEQDCB EKEQFCBA Price LeiBRC1D52 Basic wired remote controller with weekly timer • • 562,-

BRC1E53A Standard wired remote controller with full-text interface and back-light with new energy saving, sound minimization & duty rotation functions for Austria • 795,-

BRC1E53BStandard wired remote controller with full-text interface and back-light with new energy saving, sound minimization & duty rotation functions for Czech, Croatia, Hungarian, Romanian, Slovenian, Bulgarian

• 795,-

BRC1E53C Standard wired remote controller with full-text interface and back-light with new energy saving, sound minimization & duty rotation functions for Slovakian and Albanian • 795,-

KRP4A51 Adaptor for external monitoring/control • 916,-RTD-20 Adaptor for external monitoring/control with 0-10VDC linear capacity control • 2.156,-KRCS01-1 External room temperature sensor • 441,-KRC19-26 Mechanical cool/heat selector • • 311,-KJB111A Fixing box for cool/heat selector • • 151,-

Notes: - A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector

Control box EKEQDCB EKEQFCBAControl type Daikin control Free (External) control

Control options

Room temperature control [via Remote Controller (accessory) or via External room temperature sensor

(accessory)]Return air temperature control (via a supplied thermistor)

• (X-Control): 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted)

• (Y-Control): Fixed evaporation / condensation temperature control

• (W-Control): 0~10V linear capacity control (0V = 0% capacity, 10V = 100% capacity

• Connection ratio 50 ~ 110% (ERQ)Price Lei 3.711,- 3.852,-

Notes: - A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector

Page 76: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

76

ADT-FDI

Pre-sized fresh air solutionHigh end ventilation with heat recovery

ʯ Pre-sized making selection, quotation, ordering easy ʯ Connects direclty to pre-selected Daikin DX outdoor units ʯ IE premium effciency motor ʯ High effciency heat wheel (heat recovery) ʯ Compact design ʯ Indoor air quality compliant with VDI hygiene guideline ʯ Operating limits from - 20°C up to +46 °C ambient temperature ʯ Direct integration in intelligent Touch Manager for monitoring and control

ADT03FDI-80 ADT03FDI-100 ADT03FDI-125 ADT04FDI-125 ADT04FDI-140 ADT04FDI-200 ADT05FDI-200 ADT05FDI-250

Airflow Nominal Air Flow valid forCooling (1) and Heating(2)

m3/h 2.200 2.700 3.200 3.600 4.100 4.700 5.500 6.200

Expansion valve kit

Type EKEXV80 EKEXV100 EKEXV125 EKEXV125 EKEXV140 EKEXV200 EKEXV200 EKEXV250Number 1

Control box Type EKEQFCBANumber 1

Outdoor unit Type ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ200AW1 ERQ250AW1Number 1

Energy Rating Eurovent Energy Class A+ A A+ A A+ AERP Compliance ErP 2018

Heat Recovery Technology

Winter Nom. % Sorption Heat Wheel

Heat Recovery Technology

Winter Nom. % 81,5 79,2 76,9 81,1 79,6 77,8 79 77,4

ESP Nom. Pa 200SFPv Nom. W/(m3/s) 1.388 1.508 1.660 1.402 1.512 1.637 1.456 1.575Supply Fan power input Nom. W 0,53 0,7 0,92 0,89 1,08 1,35 1,4 1,72Filter class Supply F7+ F7

Extract F7+ F7Dimensions Unit Height mm 1.540 1740

Width mm 2.500 2.620 2.780Depth mm 990 1.200 1.400

Weight Kg 549 659 840Total Power Input Nom. kW 1,55 2 2,3 2,25 2,63 3,15 3,25 3,86Power supply Electrical voltage V/ph/Hz 230V/1Ph/50Hz 400V/3Ph/50HzDoor opening (following supply air direction) Right

ADT06FDI-250 ADT07FDI-250 ADT07FDI-140 ADT07FDI-200 ADT08FDI-200 ADT09FDI-200 ADT09FDI-250 ADT10FDI-250

Airflow Nominal Air Flow valid forCooling(1) and Heating(2)

m3/h 6.900 7.400 8.000 8.700 10.000 11.500 13.200 14.900

Expansion valve kit

Type EKEXV250 EKEXV140 EKEXV200 EKEXV250 EKEXV250Number 1 2

Control box Type EKEQFCBANumber 1 2

Outdoor unit Type ERQ250AW1 ERQ140AV1 ERQ200AW1 ERQ250AW1Number 1 2 2 2

Energy Rating Eurovent Energy Class A A+ A A+ A A+ERP Compliance ErP 2018

Heat Recovery Technology

Winter Nom. % Sorption Heat Wheel

Heat Recovery Technology

Winter Nom. % 77,9 80,2 79,3 78,1 78,4 79,7 77,9 80,2

ESP Nom. Pa 200SFPv Nom. W/(m3/s) 1.580 1.438 1.491 1.581 1.429 1.438 1.569 1.397Supply Fan power input Nom. W 1,86 1,82 2,04 2,35 2,48 2,82 3,54 3,62Filter class Supply F7+ F7

Extract F7+ F7Dimensions Unit Height mm 1.920 2.180 2.460 2.570

Width mm 2.980 3.100 3.150 2.980 3.100Depth mm 1.400 1.600 1.940 2.300

Weight Kg 887 1.063 1.489 1.594 1.973Total Power Input Nom. kW 4,14 4,07 4,48 5,08 5,37 6,06 7,44 7,6Power supply Electrical voltage V/ph/Hz 400V/3Ph/50HzDoor opening (following supply air direction) Right

(1) Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m

(2) Heating: indoor temp. 20°CDB; outdoor temp. -15°CDB; equivalent refrigerant piping: 5m; level difference: 0m

Page 77: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 77

Air handling unitsA

ir flo

w (m

3 /h x

1,00

0)

0

20

40

50

60

70

80

90

100

120

140

D-AHU Professional

750 m3/hup to 144.000 m3/h

Modular P ʯ Pre-configured sizes ʯ Plug and play concept ʯ EC Fan technology ʯ High efficiency alumin-ium counter flow plate heat exchanger

ʯ Compact design

D-AHU Modular R D-AHU

Modular P D-AHU Modular L

500 m3/hup to 25.000 m3/h

500 m³/h up to 15.000 m³/h

100 m³/h up to 3.400 m³/h

Professional ʯ Pre-configured sizes ʯ Tailored to the individual customer ʯ Modular construction

Modular R ʯ Pre-configured sizes ʯ Plug and play concept ʯ EC fan technology ʯ Heat recovery wheel (sorption and sensible

ʯ technology) ʯ Compact design

ʯ Modular L ʯ Pre-configured sizes ʯ Plug and play concept ʯ EC Fan technology ʯ High efficiency alumin-ium counter flow plate heat exchanger

ʯ Low height unit ʯ For false ceiling appli-cations

Products overview

Page 78: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

78

Air handling units

Eurovent certificationDaikin Applied Europe S.p.A. participates in the Eurovent Certified Performance programme for Air Handling Units.Check ongoing validity of certificate: www.eurovent-certification.com or www.certiflash.com

Eurovent Classification according to EN1886

Casing strength class

Max. relative deflection mm x m-1D1

4,00

L10,15

L10,22

F90,50

T1U <= 0,5

TB10,75 < Kb <= 1

F81

T20,5 < U <= 1

TB20,6 < Kb <= 0,75

F64

T41,4 < U <= 2

TB40,3 < Kb <= 0,45

F72

T31 < U <= 1,4

TB30,45 < Kb <= 0,6

G1 TO F56

T5No requirements

TB5No requirements

D210,00

L20,44

L20,63

D3EXCEEDING10

L31,32

L31,90

Casing air leakage class at -400 Pa Max. leakage rate (f400) l x s-1 x m-2

Casing air leakage class Max. leakage rate (f700) l x s-1 x m-2

Filter bypass leakage classMax. filter bypass leakage rate k in % of the volume flow rate

Thermal transmittance(U) W/m2 x K

Thermal bridging factor(kb) W x m-2 x K-1

D1

L1

L1

F9

T2

TB2

Energy TermiC° S2

Quickly select your air handling unit by following the wizard:

1 Select the series: D-AHU Professional or D-AHU Modular R

2 Insert the air flow supply and return

3 Insert the summer/winter air supply setpoint

4 Insert the summer/winter outdoor and extract temperature

You will get immediately your 3D result and it’s ready to customize!

Adding or changing the components: coils for the Modular R or filters, recuperators etc for the Professional range.Options as insultation type and metal sheet can be selected.

When finished a technical report, price list, fan curve chart and psychrometric chart can be generated. These final reports can be downloaded in different formats.

Selection softwareASTRA Web ʯ Quick AHU selection that will save you precious time, drastically reducing selection time through the new software interface.

ʯ Very competitive solution available within the Wizard thanks to pre-uploaded parameters.

ʯ High selection quality, thanks to the intelligence embedded with-in the software core.

Page 79: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 79

ALB-R/LB(S)

Premium efficiency heat recovery ventilation unit

ʯ Available in 6 sizes with an air flow up to 3.600 m3/h ʯ Compliant with VDI 6022 ʯ Exceeding ERP 2018 requirement ʯ Reduced energy consumption thanks to EC fans with IE4 motor efficiency

ʯ From 150 Pa up to 500 Pa of external static pressure, depending on the model sizes

ʯ Premium quality counter flow plate heat exchanger with efficiency up to 93%› Smallest size is 280 mm of height, while the biggest size is 500 mm of height

ʯ Energy saving solution thanks to the 100% automatic bypass ʯ Free-cooling operation and energy efficient defrost logic ʯ Double filter on supply and return, up to F7+F9 filtration level ʯ Possibility to have pre – filter (G4, M5, F7) ʯ CO

2 level management thanks to optional CO

2 sensor

ʯ 50 mm double skin panels, mineral wool insulated ʯ Modbus and BACnet compatible (accessory) ʯ Available also with integrated heating coil (water)

Modular Light / Smart

ALB-R/LB(S)(1) 02 03 04 05 06 07ALB-R/LB Lei 44.342,- 52.284,- 68.457,- 76.646,- 98.126,- 104.428,-ALB-R/LBS (Smart) Lei 39.158,- 47.188,- 63.398,- 71.603,- 93.101,- 99.560,-Airflow/Airflow Smart m3/h 300 600 1.200 1.500 2.500/2.300 3.000Thermal efficiency(2)/Thermal efficiency(2) Smart % 93/90 93/91 93/90 92/90 94/92 93/91External static pressure Nom. Pa 100 100 100 100 100 100Current/Current Smart Nom. A 0,52 1,17 1,91 2,48 4,39/3,76 5,39Power input/Power input Smart Nom. kW 0,12 0,27 0,44 0,57 1,01/0,87 1,24SFPv (3) /SFPv Smart kW/m3/s 1,24 1,49 1,25/1,28 1,31/1,32 1,42/1,32 1,46Electrical supply Phase ph 1 1 1 1 1 1

Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60Voltage V 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac 220/240 Vac

Dimensions unit Width mm 920 1.100 1.600 1.600 2.000 2.000Height mm 280 350 415 415 500 500Length mm 1.660 1.800 2.000 2.000 2.000 2.000

Weight unit kg 125 180 270 280 355 360

Rectangular duct flangeWidth mm 250 400 500 500 700 700Height mm 150 200 300 300 400 400

Unit sound power level/Unit sound power level Smart dBA 48 54 57 53 62/60 57Unit sound pressure level(4)/Unit sound pressure level Smart dBA 34 39 41 37 46 41

ʯ VAM PCB (Smart) ʯ F1/F2 and P1/P2 protocol (Smart) ʯ Fully compatible with SkyAir and VRV systems (Smart) ʯ Direct integration into DIII-net (Smart) ʯ Controlled through any Daikin local, centralized controllers iTAB, iTM, iTC (Smart)

NEW

Page 80: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

80

Accessories for ALB-R/LB 02 03 04 05 06 07

Compact filter

G4ALF02G4A ALF03G4A ALF05G4A ALF07G4A

Lei 204,- 242,- 299,- 337,-

M5ALF02M5A ALF03M5A ALF05M5A ALF07M5A

Lei 613,- 836,- 1.154,- 1.396,-

F7ALF02F7A ALF03F7A ALF05F7A ALF07F7A

Lei 631,- 893,- 1.174,- 1.416,-

F9ALF02F9A ALF03F9A ALF05F9A ALF07F9A

Lei 688,- 950,- 1.249,- 1.454,-

Silencer 900 mm depthALS0290A ALS0390A ALS0590A ALS0790A

Lei 2.346,- 3.429,- 4.636,- 6.612,-

Probes

CO2

ALP00COALei 5.178,-

Humidity (%RH)ALP00HUA

Lei 2.979,-

TemperatureALP00TEA

Lei 613,-

Coil module

Electric pre -heating

ALD02HEFA ALD03HEFA ALD05HEFA ALD07HEFALei 13.784,- 14.379,- 19.167,- 25.109,-

Electric post - heating

ALD02HESA ALD03HESA ALD05HESA ALD07HESALei 13.988,- 14.734,- 22.781,- 25.109,-

Water cooling (post - heating)

ALD02CWSA ALD03CWSA ALD05CWSA ALD07CWSALei 9.181,- 10.617,- 12.816,- 17.546,-

Water heating (pre/post - heating)

ALD02HWUA ALD03HWUA ALD05HWUA ALD07HWUALei 4.157,- 4.361,- 6.204,- 8.550,-

Mechanical accessories

RailALA02RLA ALA03RLA ALA05RLA ALA07RLA

Lei 1.454,- 1.563,- 1.771,- 1.919,-Rectangular - Circular duct transition

ALA02RCA ALA03RCA ALA05RCA ALA07RCALei 950,- 1.435,- 1.659,- 2.199,-

Valves

2-way valve water heating

ALV02HW2A ALV03HW2A ALV05HW2A ALV07HW2ALei 561,- 613,- 821,- 893,-

3-way valve water heating

ALV02HW3A ALV03HW3A ALV05HW3A ALV07HW3ALei 688,- 821,- 893,- 950,-

2-way valve water cooling

ALV02CW2A ALV03CW2A ALV05CW2A ALV07CW2ALei 561,- 613,- 821,- 893,-

3-way valve water cooling

ALV02CW3A ALV03CW3A ALV05CW3A ALV07CW3ALei 688,- 821,- 893,- 950,-

Electrical Accessories Modulating actuator

ALE00AMVALei 1.848,-

Controls

Module bacnet InterfaceALC00908A

Lei 1.981,-Module modbus Interface

ALC00902ALei 1.283,-

Room thermostat (included in the main unit)

ALC00822ALei 850,-

Commissioning moduleALC00895A

Lei 2.237,-

Notes: (1) R= right connection and L= left connection; S = Smart Solution (Daikin PCB)

(2) Nominal condition: Outdoor: -10°C (-5°C for Modular Light Smart), 90% Indoor: 22°C, 50%

(3) SFPv is a parameter that quantifies the fan efficiency (the lower it is the better will be). This reduces if airflow decreases.

(4) EN 3744. Surrounding, Directivity (Q) = 2, @1,5m distance

Accessories for ALB-R/LBS 02 03 04 05 06 07

Compact filter

G4ALF02G4A ALF03G4A ALF05G4A ALF07G4A

Lei 204,- 242,- 299,- 337,-

M5ALF02M5A ALF03M5A ALF05M5A ALF07M5A

Lei 613,- 836,- 1.154,- 1.396,-

F7ALF02F7A ALF03F7A ALF05F7A ALF07F7A

Lei 631,- 893,- 1.174,- 1.416,-

F9ALF02F9A ALF03F9A ALF05F9A ALF07F9A

Lei 688,- 950,- 1.249,- 1.454,-

Silencer 900 mm depthALS0290A ALS0390A ALS0590A ALS0790A

Lei 2.346,- 3.429,- 4.636,- 6.612,-

Probes CO2

BRYMA200Lei on request

Coil module Electric pre -heating

ALD02HEFB ALD03HEFB ALD05HEFB ALD07HEFBLei 11.107,- 11.685,- 15.748,- 20.929,-

Mechanical accessories

RailALA02RLA ALA03RLA ALA05RLA ALA07RLA

Lei 1.454,- 1.563,- 1.771,- 1.919,-Rectangular - Circular duct transition

ALA02RCA ALA03RCA ALA05RCA ALA07RCALei 950,- 1.435,- 1.659,- 2.199,-

Control Room Thermostat (Not included in the main unit)

BRC1H519W/S/KLei 914,-

Modular light / Smart

Page 81: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 81

Compact filter

Silencer

CO2 sensor

Humidity sensor Electric coil Water coil ( 2&3 way valve)

Compact filter

Silencer

CO2 sensor Electric coil

* Heating only

*

Accessories

Modular Light

Possible position of the element

Modular Smart

Possible position of the element

RETURN

AIR

RETURN

AIR

EXHAU

ST AIR

EXHAU

ST AIR

SUPPLY A

IR

SUPPLY A

IR

FRESH A

IR

FRESH A

IR

Bottom view

RETURN AIR

SUPPLY AIR

FRESH AIREXHAUST AIR

Modular Light unique features

Heat exchanger

Filtration step

Outer Panel

Fans

Inner Panel

Bypass element Panel Insulation

Premium efficiency counter flow HE

Low pressure compact filter G4, M5, F7 &F9

Pre-painted metal sheet

EC centrifugal plug fan

Aluzinc AZ185

For antifreeze and Free-cooling operation

50 mm panel insulated with mineral wool

Page 82: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

82

Daikin rooftops Flexible to suit your application

Rooftop for Retail & Department StoresRetail & department stores need challenging design because of limited space and complex building structure, containing different floors and spaces. Daikin rooftops provide the solution:

ʯ Ductwork can be connected flexibly (front, left, right, bottom) to optimize installation space.ʯ High efficiency EC plug fans are maintenance free, limiting the downtime of the system for maintenance.ʯ Extraction damper and fan ensure there is no overpressure in the building and air circulation is optimised.ʯ High indoor air quality can be guaranteed thanks to integrated fresh air provision.

Page 83: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 83

Rooftop for Warehouses & IndustryFor building managers and engineers, warehouses or industrial applications can pose serious HVAC challenges because of their size and unique design. Daikin rooftops provide the solution:

ʯ Pre-connected indoor/outdoor units and factory charged refrigerant provide cost-effective installation.ʯ High ESP up to 300Pa allows extensive ductwork to evenly distribute the air across a large space.ʯ Scroll compressor and free cooling ensure highly efficient 24/7 operation.ʯ Clogged filter alarm indicates when filter needs cleaning, ensuring optimum operation and minimized

energy consumption.

Plug & play installation as indoor and outdoor are in one package.

Supply and extract ducting ensures even distribution in the building.

Page 84: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

84

Daikin rooftops seriesAn extensive package includedin all models

Standard integrated high efficiency EC plug fansʯ Static pressure up to 300Paʯ Inverter controlledʯ Maintenance free

Standard flexible air deliveryʯ Up to 4 possible sides can be selected on site (front, left, right, bottom)

Latest pCO5 controllerʯ Direct integration into Daikin intelligent Touch Manager BMS

(via optional BACnet protocol)ʯ Easy integration in 3rd party BMS systems

ʯ Standard Modbus protocol ʯ Optional BACnet protocol

Standard clogged filter alarmʯ Indicates when a filter requires cleaningʯ Improved indoor air quality and efficiency

Hydrophilic coated aluminium fins on indoor and outdoor side

Up to 3 sides to connect the return duct

Up to 4 sides to connect the supply duct

1

4

3

2

5

ErPcompliant

2018

3 years warranty

Page 85: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 85

2 damper version, with integrated fresh air

3 damper version, with integrated fresh air and extraction

UATYQ-AFC2Y1

UATYQ-AFC3Y1

High installation flexibility and easy servicing

UATYQ-ABAY1

ʯ Easy to install ‘plug and play’ concept plus single installation configuration; no additional piping is required since indoor and outdoor sides are pre-connected

ʯ High efficiency and reliable scroll compressor

ʯ Factory pre-charged refrigerant ensures clean and efficient operation

ʯ Extraction damper integrated

ʯ Eliminates excessive overpressure in the building

ʯ UATYQ45-115AFC3Y1 models include high efficient extraction fan for optimum air circulation in larger buildings

ʯ Thermo dynamic heat recovery

ʯ Saves energy by recovering waste heat through the outdoor heat exchanger

ʯ Available on UATYQ20-55AFC3Y1

EC plug fan

Fresh air damper

Return air damper

Extraction damper

Mixing damper

Extraction fan

Fresh air damper

Supply fan Thermodynamic heat recovery

Cooling operation example

Cooling operation example

Heating operation example

ʯ Free cooling with 100% fresh air possible

ʯ Improved air quality

ʯ Energy saving using fresh outdoor air to cool the building

ʯ Standard CO2 sensor connection

ʯ Ideal balance between efficiency and indoor air quality

ʯ Includes all Base model features

Page 86: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

86

Products overview rooftopsCapacity class (kW)

System Type Model Product name Refrigerant 20 25 30 45 50 55 65 75 90 100 115

For EU region

Air cooled Heat pump

Rooftop unitWith extensive base package for high installation flexibility and

easy servicing- ‘Plug and play’ for easy installation- High efficiency- Field convertible return and supply air- Direct integration with Daikin or third party BMS- Factory pre-charged refrigerant

UATYQ-ABAY1

R-410A

• • • • • • • • • • •

Rooftop unit

2 damper version with integrated fresh air- ‘Plug and play’ for easy installation- Free cooling with up to 100% fresh air intake- High efficiency- Field convertible return and supply air- Direct integration with Daikin or third party BMS

UATYQ-AFC2Y1 • • • • • • • • • • •

Rooftop unit3 damper version with integrated fresh air and extraction- ‘Plug and play’ for easy installation- Integrated extraction damper eliminates over-pressure- Thermo dynamic heat recovery, recovering waste heat- Free cooling with up to 100% fresh air intake- Field convertible return and supply air

UATYQ-AFC3Y1 • • • • • • • • • • •

UATYQ20ABAY1

UATYQ20AFC2Y1

UATYQ20AFC3Y1

UATYQ25-30ABAY1

UATYQ25-30AFC2Y1

UATYQ25-30AFC3Y1

UATYQ45-55ABAY1

UATYQ25-30AFC2Y1

UATYQ25-30AFC3Y1

UATYQ90-115ABAY1

UATYQ90-115AFC2Y1

UATYQ90-115AFC3Y1

UATYQ65-75ABAY1

UATYQ65-75AFC2Y1

UATYQ65-75AFC3Y1

Outdoor unit fan

Drain

G4 air filter

Polyurethane insulated sandwich

panelsIndoor side

heat exchanger

EC plug fan

Outdoor side heat exchanger

Page 87: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 87

UATYQ-ABAY1BASE version: Working with 100% indoor air recirculation.

Rooftop units

UATYQ-ABAY1 20 25 30 45 50 55 65 75 90 100 115Price Lei 90.938,- 102.609,- 103.403,- 134.687,- 144.814,- 154.936,- 178.975,- 190.209,- 228.874,- 234.526,- 253.166,-Cooling capacity Nom. kW 19,5 28,0 30,4 44,1 49,2 51,6 63,5 73,9 90,3 101,6 106,8Heating capacity Nom. kW 17,9 27,0 31,3 46,1 51,9 56,3 63,8 76,6 93,3 104,5 114,2Space cooling

Capacity Pdesign kW 19,5 28,0 30,4 44,1 49,2 51,6 63,5 73,9 90,3 101,6 106,8ηs,c % 135,0 143,5 127,5 119,5 134,1 129,0 130,4 124,6 118,2 137,9 127,0

Space heating (Average climate)

Capacity Pdesign kW 17,9 27,0 31,3 46,1 51,9 56,3 63,8 76,6 93,3 104,5 114,2ηs,h % 115,4 129,0 119,5 115,4 125,2 124,8 121,0 118,2 116,0 125,3 124,3

Power input

Cooling Nom. kW 6,6 10,0 12,0 17,0 19,7 22,5 23,6 29,7 33,8 39,0 44,3Heating Nom. kW 5,8 8,0 9,6 14,6 16,3 18,1 20,0 25,1 29,9 33,2 37,3

EER 2,94 2,79 2,54 2,60 2,50 2,29 2,69 2,49 2,67 2,60 2,41COP 3,07 3,38 3,26 3,15 3,19 3,11 3,20 3,05 3,12 3,15 3,06Evaporator Supply side Fan Air flow rate m³/h 4.950 7.260 8.250 11.000 12.100 13.200 15.400 17.600 20.900 23.650 25.300

Nom. external Pa 300static pressureAir discharge direction Frontal, Left Frontal, Left, Right, Bottom Left, Right, Bottom

Return side Air intake direction Rear Rear, Right, Left RearCondensor Air flow rate Cooling m³/h 11.500 12.000 19.000 33.200 44.000Condensor Refrigerant Type / GWP R410-A / 2.087,5Condensor Charge TCO2Eq / kg 15,7 / 7,5 27,1 / 13,0 35,5 / 17,0 31,3 / 15,0 41,8 / 20,0 43,8 / 21,0 48,0 / 23,0Dimensions Unit Height x Width x Depth

mm 1.576x1.828 x1.762 2.126x1.828x1.762 1.799x2.712x2.263 1.799x3.760x2.252 2.180x4.059x2.252

Weight Unit kg 672 780 1,068 1,221 1,247 1,553 1,581 1,738 1,742 1,794Casing Colour RAL 7035Sound pressure level Cooling dBA 60 61 63 64 65Sound power level Cooling dBA 77 78 79 81 83 85Operation range

Cooling Min. ~ Max. °CDB 0 ~ 47Heating Min. ~ Max. °CWB -12,1 ~ 19,5

Power supply Voltage / Phase / Frequency V / Hz 400/3+N/50 ±5% 400/3/50 ±5%Current Recommended fuses A 25 32 40 50 63 80 100 125

Page 88: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

88

UATYQ-AFC2Y1

FC2S version: Including free cooling up to 100% with 2 dampers. Integrated fresh air management. The air extraction is done in the building separately.

Rooftop units

UATYQ-AFC2Y1 20 25 30 45 50 55 65 75 90 100 115Price Lei 98.035,- 110.732,- 111.516,- 142.557,- 152.679,- 162.807,- 189.720,- 199.491,- 239.642,- 246.316,- 263.933,-Cooling capacity

Nom. kW 19,5 28,0 30,4 44,1 49,2 51,6 63,5 73,9 90,3 101,6 106,8with 30% fresh air kW 20,9 30,0 32,5 47,8 52,3 55,1 68,1 78,9 96,7 108,2 114,2

Heating capacity

Nom. kW 17,9 27,0 31,3 46,1 51,9 56,3 63,8 76,6 93,3 104,5 114,2with 30% fresh air kW 18,3 27,5 31,8 48,8 52,6 57,2 65,5 77,8 94,9 106,0 116,6

Space cooling

Capacity Pdesign kW 19,5 28,0 30,4 44,1 49,2 51,6 63,5 73,9 90,3 101,6 106,8ηs,c % 135,0 143,5 127,5 119,5 134,1 129,0 130,4 124,6 118,2 137,9 127,0

Space heating (Average climate)

Capacity Pdesign kW 17,7 27,0 31,3 46,1 51,9 56,3 63,8 76,6 93,3 104,5 114,2ηs,h % 115,4 129,0 119,5 115,4 125,2 124,8 121,0 118,2 116,0 125,3 124,3

Power input

Cooling Nom. kW 6,6 10,0 12,0 17,0 19,7 22,5 23,6 29,7 33,8 39,0 44,3Heating Nom. kW 5,8 8,0 9,6 14,6 16,3 18,1 20,0 25,1 29,9 33,2 37,3

EER with 30% fresh air 3,14 2,95 2,67 2,74 2,60 2,41 2,85 2,61 2,82 2,73 2,53COP with 30% fresh air 3,37 3,75 3,56 3,42 3,48 3,40 3,64 3,31 3,38 3,43 3,35Evaporator Supply side Fan Air flow rate m³/h 4.950 7.260 8.250 11.000 12.100 13.200 15.400 17.600 20.900 23.650 25.300

Nom. external Pa 300static pressureAir discharge direction Frontal, Left Frontal, Left, Right, Bottom Left, Right, Bottom

Return side Air intake direction Rear Right-RearFresh air Standard yes

Ratio Standard % 30In free cooling % 100

Condensor Air flow rate Cooling m³/h 11.500 12.000 19.000 33.200 44.000Condensor Refrigerant Type / GWP R410-A / 2.087,5Condensor Charge TCO2Eq / kg 15,7 / 7,5 27,1 / 13,0 35,5 / 17,0 31,3 / 15,0 41,8 / 20,0 43,8 / 21,0 48,0 / 23,0Dimensions Unit Height x Width x Depth

mm 1.576x1.828 x1.762 2.126x1.828x1.762 1.799x2.712x2.263 1.799x4.675x2.252 2.180x4.875x2.252

Weight Unit kg 679 788 1.098 1.251 1.277 1.698 1.726 1.906 1.914 1.966Casing Colour RAL 7035Sound pressure level Cooling dBA 60 61 63 64 65Sound power level Cooling dBA 77 78 79 81 83 85Operation range

Cooling Min. ~ Max. °CDB 0 ~ 47Heating Min. ~ Max. °CWB -12,1 ~ 19,5

Power supply Voltage / Phase / Frequency V / Hz 400/3+N/50 ±5% 400/3/50 ±5%Current Recommended fuses A 25 32 40 50 63 80 100 125

Page 89: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 89

UATYQ-AFC3Y1

FC3S version: A third version including free cooling up to 100% fitted with 3 dampers. The third damper will assure the building overpressure is compensated by the unit.

OptionUATYQ-ABAY1 UATYQ-AFC2Y1 UATYQ-AFC3Y1

20-55 65-75 90-115 20 25-30 45-55 65-75 90-115 20 25-30 45-55 65-75 90-115

Remote controller for remote installation, standard there is always one controller pre-fitted onto the rooftop unit

UATYQWRC

Lei 3.377,-BMS interfaceBACnet (IP), for iTM integration )

UATYQBACNET

Lei 4.949,-Anti-vibration mountsto minimize unit vibration and enhance the sound absorption

UATYQAVM1

Lei 532,-(2 pcs) 532,-(3 pcs) 532,-(4 pcs) 532,-(2 pcs) 532,-(2 pcs) 532,-(2 pcs) 532,-(4 pcs) 532,-(4 pcs) 532,-(2 pcs) 532,-(2 pcs) 532,-(3 pcs) 532,-(4 pcs) 532,-(4 pcs)

Rainproof hood & protection grill

UATYQRAPH1 UATYQRAPH2 UATYQRAPH3 UATYQRAPH4 UATYQRAPH5 UATYQRAPH1 UATYQRAPH2 UATYQRAPH4(1) UATYQRAPH5(1)

Lei - - - 2.104,- 2.807,- 3.063,- 5.116,- 6.289,- 2.104,- 2.807,- - 5.116,-(2 pcs) 6.289,-(2 pcs)

Options

Note: (1) Requires 2 kits for both fresh air and exhaust air

UATYQ-AFC3Y1 20 25 30 45 50 55 65 75 90 100 115Price Lei 111.691,- 125.970,- 126.768,- 175.494,- 188.689,- 198.816,- 233.058,- 242.121,- 279.714,- 290.054,- 311.159,-Cooling capacity

Nom. kW 19,5 28,0 30,4 44,1 49,2 51,6 63,5 73,9 90,3 101,6 106,8with 30% fresh air kW 21,1 30,4 33,2 47,8 53,4 56,3 68,1 78,9 96,7 108,2 114,2

Heating capacity

Nom. kW 17,9 27,0 31,3 46,1 51,9 56,3 63,8 76,6 93,3 104,5 114,2with 30% fresh air kW 18,9 28,7 33,2 48,8 54,9 59,7 65,5 77,8 94,9 106,0 116,6

Space cooling

Capacity Pdesign kW 19,5 28,0 30,4 44,1 49,2 51,6 63,5 73,9 90,3 101,6 106,8ηs,c % 135,0 143,5 127,5 119,5 134,1 129,0 130,4 124,6 118,2 137,9 127,0

Space heating (Average climate)

Capacity Pdesign kW 17,9 27,0 31,3 46,1 51,9 56,3 63,8 76,6 93,3 104,5 114,2ηs,h % 115,4 129,0 119,5 115,4 125,2 124,8 121,0 118,2 116,0 125,3 124,3

Power input

Cooling Nom. kW 6,6 10,0 12,0 17,0 19,7 22,5 23,6 29,7 33,8 39,0 44,3Heating Nom. kW 5,8 8,0 9,6 14,6 16,3 18,1 20,0 25,1 29,9 33,2 37,3

EER with 30% fresh air 3,25 3,08 2,82 2,82 2,70 2,51 2,82 2,58 2,79 2,70 2,51COP with 30% fresh air 3,46 3,84 3,66 3,44 3,51 3,42 3,58 3,26 3,33 3,38 3,30Evaporator Supply side Fan Air flow rate m³/h 4.950 7.260 8.250 11.000 12.100 13.200 15.400 17.600 20.900 23.650 25.300

Nom. external Pa 300static pressureAir discharge direction Frontal, Left Frontal, Left, Right, Bottom Left, Right, Bottom

Return side Fan Air flow rate m³/min N/A 11.000 12.100 13.200 15.400 17.600 20.900 23.650 25.300

Nom. external Pa N/A 300static pressureAir intake direction Rear Rear, Right, Left Rear, Right, Left, BottomTherm. heat recovery yes no

Fresh air Standard yesRatio Standard % 30

In free cooling % 100Condensor Air flow rate Cooling m³/h 11.500 12.000 19.000 33.200 44.000Condensor Refrigerant Type / GWP R410-A / 2.087,5Condensor Charge TCO2Eq / kg 15,7 / 7,5 27,1 / 13,0 35,5 / 17,0 31,3 / 15,0 41,8 / 20,0 43,8 / 21,0 48,0 / 23,0Dimensions Unit Height x Width x Depth

mm 1.576x1.828 x1.762 2.126x1.828x1.762 1.799x3.518x2.272 1.799x5.660x2.252 2.180x5.660x2.252

Weight Unit kg 686 796 1.382 1.535 1.561 2.142 2.166 2.338 2.346 2.398Casing Colour RAL 7035Sound pressure level Cooling dBA 60 61 63 64 65Sound power level Cooling dBA 77 78 79 81 83 85Operation range

Cooling Min. ~ Max. °CDB 0 ~ 47Heating Min. ~ Max. °CWB -12,1 ~ 19,5

Power supply Voltage / Phase / Frequency V / Hz 400/3+N/50 ±5% 400/3/50 ±5%Current Recommended fuses A 25 32 40 63 80 100 125

Rooftop units

Page 90: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

90

Refr

iger

ant t

ype

*

Refr

iger

ant c

ircu

its

Inve

rter

Free

coo

ling

CompressorWater heat exchanger

Efficiency version Sound version

Swin

g

Scro

ll

Scre

w

Plat

e **

Sing

le p

ass

shel

l an

d tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Low

Redu

ced

Cooling only 0 17,5 200 500 1.000 2.000

EWAQ~BVP R-410A 1 BPHE

EWAQ~ACV3/ACW1 R-410A 1 BPHE

EWAQ~CWN/P/H R-410A 1-2 BPHE

EWAD~CF R-134a 2 EWAQ-G R-410A 1

BPHE EWAD-CZModels in the range 1200 KW – 1800 kW are available

R-134a 2-3 EWAD-TZ B R-134a 1-2 EWAH-TZ B NEW R-1234ze(E) 1-2 EWAD-T- R-134a 2 EWAT-B NEW R-32 1-2 Heat pump 0 17,5 200 500 1.000 2.000

EWYQ~BVP R-410A 1 BPHE

EWYQ~ACV3/ACW1 R-410A 1 BPHE

EWYQ~CWN/P/H R-410A 1-2 BPHE

SEHVX-BWSERHQ-BW1 R-410A 1

BPHE EWYQ~G- R-410A 1

BPHE EWYQ~F- R-410A 1-2 EWYD~BZ R-134a 2-3 Condensing unit 0 17,5 200 500 1.000 2.000

ERAD~E- R-134a 1 Multipurpose unit

0 17,5 200 500 1.000 2.000

EWYD-4Z R-134a 2

Products overviewAir cooled chillers, condensing units and Multipurpose units

* (GWP) : R-410A (2.087,5), R-134a (1.430) - ** BPHE: Brazed plate heat exchanger

NEW

Page 91: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 91

Refr

iger

ant t

ype

*

Refr

iger

ant c

ircu

its

Inve

rter

Free

coo

ling

CompressorWater heat exchanger

Efficiency version Sound version

Swin

g

Scro

ll

Scre

w

Plat

e **

Sing

le p

ass

shel

l an

d tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Low

Redu

ced

Cooling only 0 17,5 200 500 1.000 2.000

EWAQ~BVP R-410A 1 BPHE

EWAQ~ACV3/ACW1 R-410A 1 BPHE

EWAQ~CWN/P/H R-410A 1-2 BPHE

EWAD~CF R-134a 2 EWAQ-G R-410A 1

BPHE EWAD-CZModels in the range 1200 KW – 1800 kW are available

R-134a 2-3 EWAD-TZ B R-134a 1-2 EWAH-TZ B NEW R-1234ze(E) 1-2 EWAD-T- R-134a 2 EWAT-B NEW R-32 1-2 Heat pump 0 17,5 200 500 1.000 2.000

EWYQ~BVP R-410A 1 BPHE

EWYQ~ACV3/ACW1 R-410A 1 BPHE

EWYQ~CWN/P/H R-410A 1-2 BPHE

SEHVX-BWSERHQ-BW1 R-410A 1

BPHE EWYQ~G- R-410A 1

BPHE EWYQ~F- R-410A 1-2 EWYD~BZ R-134a 2-3 Condensing unit 0 17,5 200 500 1.000 2.000

ERAD~E- R-134a 1 Multipurpose unit

0 17,5 200 500 1.000 2.000

EWYD-4Z R-134a 2

Cooling capacity (kW)

Heating capacity (kW)

Air cooled chillers, condensing units and Multipurpose units

4,1~8,44

16,8~63,2

8,6~17,0

116~488

400-800

291-2.148

76,3~701

169~1.104

171~1.063

4~8,23

602~1.555

4~8,23

247~580

271~618

400-800

173~674

158~624

8,6~17,0

21,2~63,3

16,8~63,3

16,6~62,9

20,8~62,7

9,9~14,8

82,2~170

75,2~165

696~1.795

69~154

Page 92: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

92

Refr

iger

ant

Type

*

Refr

iger

ant c

ircu

its

Inve

rter

Compressor Water heat exchanger Efficiency versionSound

version

Scro

ll

Scre

w

Cent

rifu

gal

Plat

e **

Sing

le

pass

she

ll

and

tube

Shel

l and

tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Water cooled chillers (Cooling only & Heating only) 0 17,5 200 500 1.000 2.000 21.800

EWWQ-KBW1N R-410a 1-2 EWHQ~G- R-410A 1 EWWQ~G- R-410A 1 EWWQ~L- R-410A 2 EWWD~J- R-134a 1 Water cooled chillers (Cooling only) 0 17,5 200 500 1.000 2.000 21.800

EWWD-VZ R-134a 1 Flooded

EWWH-VZ NEW R-1234ze(E) 1 Flooded Condenserless chillers 0 17,5 200 500 1.000 2.000 21.800

EWLQ-KBW1N R-410a 1-2 BPHE EWLQ~G- R-410A 1 EWLQ~L- R-410A 2 EWLD~J- R-134a 1 EWLD~I- R-134a 1-2-3 Water cooled centrifugal chillers 0 17,5 200 500 1.000 2.000 21.800

EWWD-DZ NEW R-134a 1

EWWH-DZ NEW R-1234ze(E) 1 DWSCDWDC R-134a 1 optional Flooded

6,000 RT CENTRIFUGAL R-134a

2per

chiller Flooded

* (GWP) : R-410A (2.087,5), R-134a (1.430), R-407C (1.773,9) - ** BPHE: Brazed plate heat exchanger

Products overviewWater cooled and condenserless chillers

Page 93: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 93

Refr

iger

ant

Type

*

Refr

iger

ant c

ircu

its

Inve

rter

Compressor Water heat exchanger Efficiency versionSound

version

Scro

ll

Scre

w

Cent

rifu

gal

Plat

e **

Sing

le

pass

she

ll

and

tube

Shel

l and

tu

be

Stan

dard

Hig

h

Prem

ium

Stan

dard

Water cooled chillers (Cooling only & Heating only) 0 17,5 200 500 1.000 2.000 21.800

EWWQ-KBW1N R-410a 1-2 EWHQ~G- R-410A 1 EWWQ~G- R-410A 1 EWWQ~L- R-410A 2 EWWD~J- R-134a 1 Water cooled chillers (Cooling only) 0 17,5 200 500 1.000 2.000 21.800

EWWD-VZ R-134a 1 Flooded

EWWH-VZ NEW R-1234ze(E) 1 Flooded Condenserless chillers 0 17,5 200 500 1.000 2.000 21.800

EWLQ-KBW1N R-410a 1-2 BPHE EWLQ~G- R-410A 1 EWLQ~L- R-410A 2 EWLD~J- R-134a 1 EWLD~I- R-134a 1-2-3 Water cooled centrifugal chillers 0 17,5 200 500 1.000 2.000 21.800

EWWD-DZ NEW R-134a 1

EWWH-DZ NEW R-1234ze(E) 1 DWSCDWDC R-134a 1 optional Flooded

6,000 RT CENTRIFUGAL R-134a

2per

chiller Flooded

600~9.000

[ 2 x 10.900]

Cooling capacity (kW)

Heating capacity (kW)

300~4.500

21.800

449~2.074

329 - 1.540

13,2-183,8

12,5~56,71

110~264

86,5~346

173~676

315~1.433

320~2.173

227~1.415

142~350

142~280

87,3~352

118~462

93,7~370

187~721

112~468

120~280

Water cooled and condenserless chillers

16,4~225,5

Page 94: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

94

COOLING TOWER70-9.200 kW

On request we can offer you the most suita-ble cooling tower for your application.For correct selection we need following info: ʯ Heat rejection capacity (kW) or chiller type and working conditions

ʯ Liquid inlet and outlet temperature ʯ Liquid type ʯ Maximum/Minimum ambient temperature ʯ Maximum sound level ʯ Space restrictions

AIR COOLER1-162 kW

On request we can offer you the most suitable air cooler for your application based on a brine/water solution.

AIR HANDLING UNIT500-140.000 m3/h

On request we can offer you the most suitable air handling unit for your application. ʯ Air handling units for filtering, heating, cooling, humidifying, and air drying

ʯ Air handling units with heat recovery ʯ Air handling units for outdoor installation

ʯ Air handling units in hygienic execution for hospital and clean room

ʯ Air handling units with indirect gas fired heating

ʯ Air handling units for swimming pool applications

ʯ Air handling units with higher air volumes manufactured on request

ʯ Air handling units with thermal uncoupled frame

DRY COOLER & CONDENSER3-2.400 kW

On request we can offer you the most suitable dry cooler and condenser for your application.For correct selection we need following info: ʯ Heat rejection capacity (kW) or chiller type and working conditions

ʯ Liquid inlet and outlet temperature (dry cooler)

ʯ Liquid type (dry cooler) ʯ Condensing temperature (condenser) ʯ Refrigerant type and number of circuits (condenser)

ʯ Maximum/Minimum ambient temperature

ʯ Maximum sound level ʯ Space restrictions

Total solution products

COMPRESSORInspection/repair/overhaul

InspectionInspection fee/compressor* on request

RepairRepair cost/compressor*

After inspection, on quotation base

OverhaulOverhaul cost/compressor* on request

To extend the lifetime of your compressor, Daikin offers a compressor overhaul service as preventive maintenance.In case of broken compressor, Daikin can offer an inspection to determine whether the compressor is repairable or not. Based on the findings the broken parts will be replaced and the compressor will be restored into operational condition.

Remarks

The above is only valid for DAIKIN semi-hermetic

compressors

* Excluding transport cost and other site related

costs

Page 95: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 95

MENTIONED CAPACITIES, EFFICIENCY RATIOS, SOUND POWER LEVELS, DIMENSIONS Weights are indicative and valid under the following conditions:

Chillers

Air cooled unitsCooling 7 °C / 12 °C water 35 °C ambient tempHeating 40 °C / 45 °C water 7 °C ambient tempHeat recovery 7 °C / 12 °C water 40°C / 45°C heat recovery 35 °C ambient temp

Condenserless units Cooling 7 °C / 12 °C water 45 °C condensing temp / 5 K subcooling

Water cooled unitsCooling 7 °C / 12 °C evaporator water 30 °C / 35 °C condenser waterHeating 7 °C / 12 °C evaporator water 40 °C / 45 °C condenser water

Condensing unitsCooling: evaporation temperature: 6 °C outdoor temperature: 35 °C on-coil temperature: 27 °CDB / 19 °CWBHeating: condensing temperature: 46 °C outdoor temperature: 7 °C on-coil temperature: 20 °CDB

General:

evaporator superheat: 5K condenser sub-cool: 3K7,5 m equivalent refrigerant piping 0 m level difference

Fan coil units

Cooling:Room temperature DB/WB: 27 °C/19 °CEntering/Leaving water temperature: 7 °C/12 °C

Heating:Room temperature: 20 °CEntering water temperature: 50 °C (2-pipe,water flow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C)

Measuring conditions

Page 96: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

96

Service

Saving energy doesn’t stop with the purchase or installation of energy-efficient equipment; it has to be kept running under optimum conditions.

Good maintenance and servicing are key elements in ensuring the maximum performance.

Are you sure the filters are clean and none of the components are defective? Are all of your settings correct?

Any of these things may lead to a reduced level of comfort. And while you may not notice the difference right away, you will certainly notice it at the end of the year – when you pay your energy bill.

Spare parts Repair service

Installation support CommissioningCare Packages

Upgrading /

optimisation

Optimisation and upgrades

Keep the installation in top condition

Parts andrepairs

Daikin Service

Our Daikin design team is constantly striving to improve the energy efficiency of our systems.

We at Daikin Service are here to support you in keeping your units up and running efficiently by means of optimised commissioning and start-up, regular and preventative maintenance, remote monitoring, improving the performance of units, and providing cost effective upgrades to benefit from the efficiency gains from our latest state of the art technology.

European Remote

Monitoring Center

24/7

Page 97: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 97

DescriptionMaterial Number COMMISSIONING

PRICE [Lei]Type Nr. of circuits Nr. of compressors Vompressor typeMinichillers 1 1 swing CE.S_COM_APS 1.315,-Multi-Scroll chillers 1 1-2 scroll CE.S_COM_APS_S 1.770,-

2 2-4 scroll CE.S_COM_APS_S 2.276,-Screw-Chillers air- & watercooledDX-version

1 1 screw CE.S_COM_APS_S 3.287,-2 2 screw CE.S_COM_APS_M 4.045,-3 3 screw CE.S_COM_APS_M 4.804,-4 4 screw CE.S_COM_APS_M 5.816,-

Screw-Chillerswatercooled, flooded

1 1 screw CE.S_COM_APS_M 3.540,-1 2 screw CE.S_COM_APS_L 4.551,-

CentrifugalChillers

1 1 centrifugal CE.S_COM_APS_C 9.607,-1 2 centrifugal CE.S_COM_APS_C 11.915,-

AHU - - - based on quotation

Additional Services & MaterialsOn Request On RequestLabour ratesLabour hour service engineer CE.S_LA_HOUR 255,-Labour hour service engineer +50% CE.S_LA_HOUR50 375,-Labour hour service engineer +100% CE.S_LA_HOUR100 500,-Labour hour service foreman CE.S_LA_FOR 375,-Labour hour project design CE.S_LA_PRO 375,-Normal working hours without surcharge MON – THU: 08:00-17:00, FRI: 08:00-12:0050% surcharge MON – FRI: 07:00-08:00 and 17:00-20:00,SAT: 07:00-20:00100% surcharge Before 07:00 and after 20:00 and on Sundays and holidaysTravel Costs (not including parking, highway tolls etc )Cost allowance per km CE.S_TR_KM_AL On RequestFlat travel fee per case CE.S_TR_CASE On RequestSpecial travel cost (plane, ferry…) CE.S_TR_SPEC On RequestTravel zone 1 CE.S_TR_Z1 On RequestTravel zone 2 CE.S_TR_Z2 On RequestTravel zone 3 CE.S_TR_Z3 On RequestTravel zone 4 CE.S_TR_Z4 On RequestHourly rate for car travel CE.S_TR_HOUR On RequestCancellationFailed travel (customer fault) CE.S_COM_FAILTRAV 50% of planned activityTraining Full day Training per person per day (minimum 5 participants) CE.S_LA_TRA 1.552,-

ServiceService

CommissioningTo guarantee your Daikin unit efficiency and long term performance, Daikin offers the professional start-up of your Daikin system by highly qualified, OEM educated engineers as part of the commissioning services.

Commissioning through an authorized Partner or by Daikin itself assures you that your unit is working as it should and is delivering all the benefits of a unique climate.

Every commissioning is documented as per Daikin standard and a detailed commissioning report is provided, detailing all activities done and recording the functioning of the units.

The prices listed are based on completion of the Pre-Commissioning checklist which covers a range of core activities including the general conditions at the site, provision of power and the required electrical distribution as well as installation related topics. This ensures that the service can be provided efficiently, on time and giving the best results. For the latest edition of the Pre-Commissioning checklist please visit: www.daikin-ce.com

Page 98: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

98

Service

Maintenance is the key element to ensure the quality, efficiency and flawless operation of any asset. Our Care agreements are based on years of experience to ensure you reap the full benefits of having Daikin Certified engineers maintain your equipment.Preventive maintenance and regular service is a key component in securing your investment. Dust, temperature, humidity and load degrade the reliability and performance of a HVAC system over time.Regular maintenance of a unit or

Maintenancesystem ensures that electricity costs and performance are not jeopardized, and that the safety features and the entire system are in line with the latest standards and regulations.

Regular care safeguards your investment for the full lifetime of the Daikin System. Downtime and failures are avoided, while keeping operating costs low, as they should be throughout the entire system lifecycle.Preventive care plans give you cost transparency avoiding unexpected repair costs or degradation of comfort, quality or production loss.

Daikin Cares contains 3 different levels of maintenance agreements catering to your every need. In addition to these 3 Care packages Daikin offers a comprehensive set of options you can choose from.

Care is the minimal requirement to fulfil current legislation requirements, and makes sure your machine is operating in a correct fashion and according to parameters. The Care package includes the following services: • Inspections based on predefined

activities • On-site system diagnostic and/or

analysis during service intervention• Recorded, retrievable service history

of each machine• Validated Log book

1. Care: 2. Preventive Care: 3. Extended Care:

Preventive Care keeps the machine in optimal condition and that the Warranty is valid for the long run.In addition to the maintenance ac-tivities included in the Care package, Preventive Care includes: ʯ Mechanical inspection (star gate) of screw compressor

ʯ Capacity regulator overhaul ʯ Comprehensive oil analysis ʯ Lifecycle report with status & meas-urement report

ʯ Access to Emergency support & callout

ʯ Technical assistance and repair service

Extended Care provides maximum equipment availability at the minimum Total Cost of Ownership.In addition to the activities mentioned in the Preventive care package, Extended Care includes: • Oil analysis, refill and/or change if

required• Labor- & travel cost, spare parts for

planned maintenances are included ʯ Labor- & travel cost, spare parts for repairs are included

ʯ Remote Predictive Performance monitor-ing & Analysis

ʯ Extension of warrantyOptions:Leak testRemote monitoringFactory inspection/refurbishmentSpecialist support and consultancy

Description Care Preventive Care Extended Care

Maintenance Minichiller CE.S_AS_C_MINI On Request On Request

Maintenance Multi-Scroll chiller, 1 circuit, up to 2 compresors CE.S_AS_C_MS12 On Request On Request

Maintenance Multi-Scroll chiller, 2 circuits, 2-4 compresors CE.S_AS_C_MS24 On Request On Request

Maintenance Screw-Chiller, 1 circuit, 1 compresor CE.S_AS_C_SC11 On Request On Request

Maintenance Screw-Chiller, 2 circuits, 2 compresors CE.S_AS_C_SC22 On Request On Request

Maintenance Screw-Chiller, 3 circuits, 3 compresors CE.S_AS_C_SC33 On Request On Request

Maintenance Screw-Chiller, 4 circuits, 4 compresors CE.S_AS_C_SC44 On Request On Request

Maintenance Centrifugal Chiller, 1 circuit, 1 compresor CE.S_AS_C_CC11 On Request On Request

Maintenance Centrifugal Chiller, 1 circuit, 2 compresors CE.S_AS_C_CC12 On Request On Request

OptionsDescriptionFactory inspection/refurbishment On RequestSpecialist support and consultancy On RequestMajor Overhaul On Request

Daikin Cares contains 3 different levels of maintenance agreements catering to your every need. In addition to these 3 Care packages Daikin offers a comprehensive set of options you can choose from.

Description DoS1 DoS2 DoS3

Daikin on Site (DoS) -Applied Systems (AS) On Request On Request On Request

Daikin on Site (DoS) - Air Handling Units (AHU) On Request On Request On Request

Page 99: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 99

Service

Find the correct spare part for your Daikin unit, check availability (real-time) and order online.

All in just a few simple steps. Your benefits:

› fast handling › free shipment › 24/7 accessibility › flexible delivery › “real time” availability

E-Parts

Always accessible for youYou can find the links to E-Parts and to the spareparts bank on our Business Portal:

http://eparts.daikin-ce.comhttps://my.daikin.eu

Register now to use the E-Parts service

Create access for you and your colleagues. - Simply go to my.daikin.eu- download the registration form- fill it in - and email it back to your local Daikin office

Service Academy

ACADEMY Central Europe

Goals & Objectives

With the Daikin Service Academy we want to offer a uniform European learning program for service technicians (internal & external) to become the best of the best.

ʯ Ensure that our partners have skilled labour available ʯ Enable and deliver high quality Service to our end users ʯ Enhance performance and efficiency, using less time for service interventions

ʯ Improve quality and hence customer satisfaction on site ʯ Foster career paths to keep service technicians in the HVAC-R industry

ʯ Offer trainings in local language wherever possible

Want to know more?

Please contact us for more information about the Daikin Academy Central Europe: [email protected]

The Daikin Service Academy offers individual learning paths covering all service cases for Daikin products.Our goal is to help you delivering better Service on site and therefore grow your business.

Our training packages cover following areas:

ʯ Installation & Pre-Commissioning ʯ Commissioning ʯ Maintenance ʯ Troubleshooting & Repair ʯ Application & Design

Page 100: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

100

Service

Remote Monitoring

Services

The benefits of remote monitoring

Remote control

Daikin Cloud Service is a web-based remote monitoring and control solution for HVAC systems that can even manage the energy consumption of several buildings at once. There’s no need to install any special software. Everything is accessible using a standard browser, whether via a computer or a mobile device.

Analytics

Data is our raw material, and data analytics is our product. The continuous monitoring and analysis of a system’s operating data is not only the key to ensuring efficient operation, cutting operating and maintenance costs and optimizing user comfort. Data analysis also provides further valuable and often surprising insights.

No potential problem goes unnoticed

What’s more, Daikin Cloud Service provides automatic notification if it detects a possible malfunction. This unique predictive notification feature enables service measures to be initiated even before the user notices that a problem has arisen – thus maximizing reliability and minimizing service costs.

Hassle-free connection

We know that connecting a system to the cloud can often be a real challenge – but that‘s no longer your problem. We’ll take care of the connection, including the mobile network and the router, both of which are remotely monitored to maximize infrastructure reliability.

Maximum performance

The performance of even the best system can be impaired if it is not properly operated. Continuous monitoring allows load profiles, usage patterns and operating conditions to be closely followed. The data obtained is the basis for optimizing a system‘s operation and maintenance as well as its return on investment.

Daikin Cloud Service

Our web-based service provides reliable and secure remote monitoring. Our top priority is to earn your trust. Daikin Cloud Service meets the highest security standards in all respects – safeguarding your data privacy as well as transporting and storing your data securely at all times.

The latest technology matched with superb service to improve the efficiency and reliability of your HVAC-R installation.

Connected air conditioning works smarter. We offer several ways to

manage your products and installations remotely. From performance

monitoring to predictive logic and analyses and more, our Intelligent

Network is a cost-efficient way to increase the security, uptime and relia-

bility of your installation.

Page 101: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 101

Higher outlet temperature

Thanks to operation data analysis, we identified the possible comfort issues. Following operation assessment provided the base for taking the countermeasures to increase their comfort.

Real caseReal life examples, how continuous monitoring and data analysis could be useful:

Lower VRV consumption

Thanks to analysis of the VRV systems energy consumption data, we could provide the recommendation, how to change the usage pattern. The result was 20% reduction of electricity costs for cooling and about 15% in heating.

Spare refrigeration capacity

Long term monitoring of the Conveni pack, identified that the client has a 40% spare refrigeration capacity. This allowed to reduce the number of installed devices and thus save the investment costs.

Lower investment costs

Operation data analysis of the old VRV system confirmed, that the replacement capacity and system layout could be optimized. This allowed to decrease investment costs of the replacement system and to resolve comfort issues.

Page 102: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

102

Notes

Page 103: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Applied Systems Price List 2019-2020 103

Notes

Page 104: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

DAIKIN AIRCONDITIONING CENTRAL EUROPE – ROMANIA SRL

169A Calea Floreasca, Building B, floor 8, RO – 014459 Bucharest, Phone: +40 / 21 / 307 97 00, Fax: +40 / 21 / 307 97 29, e-mail: [email protected], www.daikin.ro

Daikin products are distributed by:

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. / Daikin Central Europe HandelsGmbH. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH have compiled the content of this publication to the best of their knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

Daikin Europe N.V. participates in the Eurovent Certification

programme for Liquid Chilling Packages (LCP), Air handling

units (AHU) and Fan coil units (FCU), Check ongoing validity

of certificate online: www.eurovent-certification.com or

using: www.certiflash.com

DACE Applied Systems Pricelist 2019-2020 | Version February 2019 We reserve the right for printing errors and model changes

Future-proof choice in chillers

EWAT-B - First air cooled chiller series with R-32 and free-cooling options

Page 105: Pricelist 2019-2020 Applied Systems - Daikin · 2020. 9. 25. · The state-of the-art testing centre follows a rigorous set of procedures to ensure proper operation of Daikin products

Price

list 20

19