Pricelist 2017-2018 Applied Systems - Klimatizace · PDF filePricelist 2017-2018 Applied...
Transcript of Pricelist 2017-2018 Applied Systems - Klimatizace · PDF filePricelist 2017-2018 Applied...
Pricelist 2017-2018
Applied Systems
Prices and technical information for Applied Systems
Applied Systems Price list -
Type Refrigerant Compressor Material Capacity PageKey information - Ecodesign directive and Energy Labelling
Air cooled chiller Inverter R-A Swing EWAQ-A & EWAQ-B - kW
Air cooled heat pump Inverter R-A Swing EWYQ-A & EWYQ-B - kW
Air cooled chiller Inverter R-A Scroll EWAQ-BAW - kW
Air cooled heat pump Inverter R-A Scroll EWYQ-BAW - kW
Air cooled heat pump Inverter - split version R-A Scroll SEHVX - AAW + SERHQ-AAW - kW
NEW Air cooled chiller - Product description
Air cooled chiller - standard effi ciency - standard noise R-A Scroll EWAQ-G-SS - kW
Air cooled chiller - standard effi ciency - reduced noise R-A Scroll EWAQ-G-SR - kW
Air cooled chiller - high effi ciency - standard noise R-A Scroll EWAQ-G-XS - kW
Air cooled chiller - high effi ciency - reduced noise R-A Scroll EWAQ-G-XR - kW
Air cooled heat pump - high effi ciency - standard noise R-A Scroll EWYQ-G-XS - kW
Air cooled heat pump - high effi ciency - reduced noise R-A Scroll EWYQ-G-XR - kW
Water cooled chiller R-C Scroll EWWP-KBWN - kW
Water cooled chiller R-C Scroll EWWP-KAWM - kW
NEW Water cooled chiller - Product description
Water cooled chiller - standard effi ciency R-A Scroll EWWQ-G-SS - kW
Water cooled heat pump - standard effi ciency R-A Scroll EWHQ-G-SS - kW
Water cooled chiller - standard effi ciency R-A Scroll EWWQ-L-SS - kW
Condenserless chiller R-C Scroll EWLP-KBWN - kW
Condenserless chiller - standard effi ciency R-A Scroll EWLQ-G-SS - kW
Condenserless chiller - standard effi ciency R-A Scroll EWLQ-L-SS - kw
Condensing unit heat pump Inverter R-A Scroll ERQ - kW
Hydronic Kit EKBT / EHMC
Rooftop heat pump R-A Scroll UATYQ-CY - kW
Rooftop heat pump R-C Scroll UATYP-AY - kW
Fan coil
Low ESP duct FWE-C , - kW
Medium ESP duct FWB-B , - kW
Medium ESP duct / BLDC FWP-A , – , kW
Medium ESP duct / BLDC FWN-A , - , kW
High ESP fl exi duct FWD-A , - kW
Cassette x FWF-C , - , kW
Cassette x FWF-B , - kW
Cassette x FWC-B - , kW
Cassette × FWG- A ,-, kW
Wall mounted FWT-C , - , kW
Floor standing FWV-D , - kW
Flexi type FWL-D , - kW
Flexi concealed FWM-D , - kW
Floor standing / BLDC FWZ-A , - kW
Flexi type / BLDC FWR-A , - kW
Flexi concealed / BLDC FWS-A , - kW
Air Handling Units - AHU D-AHU Modular - m/h
Overview: Air cooled chiller portfolio
Overview: Portfolio Water cooled and Condenserless units
Air Cooler
Air Handling Unit
Dry Cooler & Condenser
Cooling Tower
Compressor Service
Measuring conditions
Daikin Service: Commissioning and Maintenance
Commercial terms and conditions
Table of contents
NOTE:All prices are list prices, excl. VAT and valid from June till . March .
All prior pricelists are not valid anymore. The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com/legal-notice.jsp).
We reserve the right for printing errors and model changes. The LOT& regulation requires the manufacturers to publish additional energy effi ciency data
for some products shown in this literature. From September , these required effi ciency data can be publicly viewed and downloaded from the following
free access website: www.daikineurope.com/energylabel/lot_/Daikin.
Ecodesign Directive and Energy Labels
The Ecodesign Directive defi nes the minimum
standards for the environmental characteristics
of heaters, water heaters and combi appliances.
From September , heat generators of
up to kW output and tanks of up to litres
must be marked with a label showing their energy
effi ciency. This applies to all individual products
(product label) and heating systems (package label)
brought onto the market from this date. In addition,
a product datasheet containing detailed information
must be made available for each item.
From green to red
The principle is well-known from
refrigerators, washing machines and TV
sets: Devices and appliances are split
into effi ciency classes on a scale from
A+++ to G. Dark green represents the
highest level of effi ciency, dark red the
lowest. The scales diff er between the
individual product groups.
Identical across Europe
The Ecodesign Directive for heat generators
and water heaters, and the obligation to identify
products and system solutions with energy labels,
will apply to all member states of the European
Union. The aim is to promote the manufacture
and development of more environmentally
responsible and energy effi cient heating systems and
to simplify comparisons for consumers.
Heat generators
20
15
20
19
Water heaters Packages
20
15
20
17
20
15
Key Information
Applied systems:
products in scope
Since , all air conditioners and air-to-air heat
pumps under kW are in scope of this Eco-Design
directive.
Since September , heat generators for space
heating (LOT ) also need to comply to these --
targets. For the applied systems market it means
that all heat pumps below kW need to comply
to minimum effi ciency requirements. Heat pumps
below kW must be marked with a product energy
label.
Our service
Daikin helps it partners to meet their obligations
regarding the Ecodesign Directive and energy
labelling. Labels, product and technical fi ches for
each individual product are available as downloads at
any time from the Energy Label Generator at
www.daikineurope.com/energylabel/lot1_2/Daikin.
A
S
p
d
S
h
t
t
t
bb
l
Applied Systems Price list -
Unit size (1 phase) EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP
Price CZK 81.448,- 89.313,- 98.959,-
Cooling capacity kW 5,2 6 7,1
EER 2,75 2,55 2,41
ESEER 3,75 3,83 3,87
Sound power level dB(A) 62 62 63
Options
OP10 evaporator heater tape CZK 10.222,- 10.222,- 10.222,-
Unit size (1 phase) EWAQ004BAVP EWAQ005BAVP EWAQ006BAVP EWAQ008BAVP
Price CZK 76.923,- 83.835,- 89.856,- 99.252,-
Cooling capacity kW 4,00 4,93 5,88 7,95
EER 3,14 3,06 3,15 3,1
ESEER 4,45 4,49 5,25 5,24
Sound power level dB(A) 63,0 64,2 n.a. 69,6
Options
OP10+OPZL
evaporator heater tape
Piping insulation + low leaving water
temperature (down to -10°C)
CZK 9.855,- 9.855,- 9.747,- 9.747,-
Unit size (1 phase) EWAQ009ACV3P EWAQ010ACV3P EWAQ011ACV3P
Price CZK 112.909,- 119.568,- 128.475,-
Cooling capacity kW 8,6 9,6 11,1
EER 3,05 2,93 2,85
ESEER 4,31 4,3 4,33
Sound power level dB(A) 64 64 64
Options
OP10 evaporator heater tape CZK 16.607,- 16.607,- 16.607,-
EKRP1HBA digital I/0 PCB CZK 4.202,- 4.202,- 4.202,-
Unit size (3 phase) EWAQ009ACW1P EWAQ011ACW1P EWAQ013ACW1P
Price CZK 117.814,- 129.543,- 137.217,-
Cooling capacity kW 9,1 11,1 13,3
EER 2,99 2,85 2,57
ESEER 4,43 4,44 4,36
Sound power level dB(A) 64 64 66
Options
OP10 evaporator heater tape CZK 16.607,- 16.607,- 16.607,-
EKRP1HBA digital I/0 PCB CZK 4.202,- 4.202,- 4.202,-
*Note: blue cells contain preliminary data
EWAQ-A
Air cooled chiller inverter
High ESEER thanks to inverter technology, integrated hydronics.
EWAQ-A
Unit size (1 phase) EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP
Price CZK 94.081,- 101.700,- 112.525,-
Cooling capacity kW 5,2 6 7,1
EER 2,75 2,55 2,41
Heating capacity kW 5,65 6,35 7,75
COP 2,87 2,83 2,74
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)% 133 134
SCOP 3,39 3,40 3,41
Seasonal space heating
eff . classA+ A+ A+
Sound power level dB(A) 62 62 63
Options
OP10 evaporator heater tape CZK 10.222,- 10.222,- 10.222,-
Unit size (1 phase) EWYQ004BAVP EWYQ005BAVP EWYQ006BAVP EWYQ008BAVP
Price CZK 85.536,- 93.150,- 99.873,- 110.322,-
Cooling capacity kW 4,00 4,93 5,88 7,95
EER 3,14 3,06 3,15 3,10
ESEER 4,45 4,49 5,25 5,24
Heating capacity kW 4,11 5,00 6,32 8,30
COP 3,44 3,41 3,30 3,33
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)% n.a. n.a. n.a. n.a.
SCOP n.a. n.a. n.a. n.a.
Seasonal space heating
eff . classn.a. n.a. n.a. n.a.
Sound power level dB(A) 63,0 64,2 n.a. 74,0
Options
OP10+OPZL
evaporator heater tape
Piping insulation + low leaving
water temperature (down to -10°C)
CZK 9.855,- 9.855,- 9.747,- 9.855,-
EWYQ-A
Air cooled heat pump inverter
Wide operation range - ambient temperature in heating down
to -°C.
EWYQ-A
Unit size (1 phase) EWYQ009ACV3P EWYQ010ACV3P EWYQ011ACV3P
Price CZK 129.982,- 136.833,- 145.082,-
Cooling capacity kW 8,6 9,6 11,1
EER 3,05 2,93 2,85
ESEER 4,31 4,3 4,33
Heating capacity kW 9,9 11,4 12,9
COP 3,3 3,29 3,27
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)% 126 131 134
SCOP 3,22 3,34 3,41
Seasonal space heating
eff . classA+ A+ A+
Sound power level dB(A) 64 64 64
Options
OP10 evaporator heater tape CZK 16.607,- 16.607,- 16.607,-
EKRP1HBA digital I/0 PCB CZK 4.202,- 4.202,- 4.202,-
Unit size (3 phase) EWYQ009ACW1P EWYQ011ACW1P EWYQ013ACW1P
Price CZK 135.052,- 146.617,- 154.920,-
Cooling capacity kW 9,1 11,1 13,3
EER 2,99 2,85 2,57
ESEER 4,43 4,44 4,36
Heating capacity kW 10,9 12,4 13,9
COP 3,28 3,27 3,25
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)% 126 134 130
SCOP 3,22 3,41 3,30
Seasonal space heating
eff . classA+ A+ A+
Sound power level dB(A) 64 64 66
Options
OP10 evaporator heater tape CZK 16.607,- 16.607,- 16.607,-
EKRP1HBA digital I/0 PCB CZK 4.202,- 4.202,- 4.202,-
*Note: blue cells contain preliminary data
COMING SOON
COMING SOON
Applied Systems Price list -
Unit size EWAQ016BAW EWAQ021BAW EWAQ025BAW EWAQ032BAW EWAQ040BAW EWAQ050BAW EWAQ064BAW
Price CZK 208.333,- 245.247,- 276.599,- 319.104,- 421.982,- 470.188,- 542.893,-
Cooling Capacity (MAX) EWAQ - BAWN / BAWP kW 20,6 / 19,8 25,7 / 24,7 30,6 / 29,5 38,2 / 36,8 51,4 / 49,5 61,4 / 59,3 76,4 / 74,2
Cooling capacity (nominal) EWAQ - BAWN / BAWP kW 17,4 / 16,6 21,7 / 20,7 25,8 / 24,7 32,3 / 30,9 43,4 / 41,5 51,8 / 49,7 64,5 / 62,3
ESEER (nominal) EWAQ - BAWN / BAWP 4,33 / 4,21 4,08 / 4,18 3,85 / 4,04 3,39 / 3,62 4,19 / 4,24 3,96 / 4,12 3,64 / 3,78
Sound power level dB(A) 78 78 78 80 81 81 83
Options
OP10 Evaporator electric heater CZK 16.936,- 16.936,- 16.936,- 16.936,- 21.321,- 21.321,- 21.321,-
OPSP One centrifugal pump (low lift) CZK 18.855,- 18.855,- 18.855,- 25.048,- 25.048,- 25.048,- 25.048,-
OPHP One centrifugal pump (high lift) CZK 27.597,- 27.597,- 27.597,- 27.597,- 37.490,- 37.490,- 37.490,-
OPZL Low leaving water operation down to
-10 °CCZK 12.689,- 12.689,- 12.689,- 12.689,- 16.936,- 16.936,- 16.936,-
Kit
EKRP1AHTDemand PCB Remote:
On/Off , Cool/heat, thermo On/Off CZK 4.216,- 4.216,- 4.216,- 4.216,- 8.433,- 8.433,- 8.433,-
EKRUAHT Additional remote user interface CZK 7.016,- 7.016,- 7.016,- 7.016,- 7.016,- 7.016,- 7.016,-
BHGP26A1 Digital pressure gauges CZK 16.059,- 16.059,- 16.059,- 16.059,- 32.119,- 32.119,- 32.119,-
DTA104A62External adaptor for:
Demand and Low noise control CZK 12.327,- 12.327,- 12.327,- 12.327,- 24.654,- 24.654,- 24.654,-
RTD-W Modbus interface CZK 10.426,- 10.426,- 10.426,- 10.426,- 10.426,- 10.426,- 10.426,-
Unit size EWYQ016BAW EWYQ021BAW EWYQ025BAW EWYQ032BAW EWYQ040BAW EWYQ050BAW EWYQ064BAW
Price CZK 239.602,- 282.052,- 318.145,- 366.871,- 485.178,- 540.564,- 624.341,-
Cooling Capacity (MAX) EWYQ - BAWN / BAWP kW 20,6 / 19,8 25,7 / 24,7 30,6 / 29,5 38,2 / 36,8 51,4 / 49,5 61,4 / 59,3 76,4 / 74,2
Cooling capacity (nominal) EWYQ - BAWN / BAWP kW 17,4 / 16,6 21,7 / 20,7 25,8 / 24,7 32,3 / 30,9 43,4 / 41,5 51,8 / 49,7 64,5 / 62,3
ESEER (nominal) EWAQ - BAWN / BAWP 4,33 / 4,21 4,08 / 4,18 3,85 / 4,04 3,39 / 3,62 4,19 / 4,24 3,96 / 4,12 3,64 / 3,78
Heating capacity (MAX) EWYQ - BAWN / BAWP kW 19,4 / 20,2 24,4 / 25,4 29,4 / 30,5 36,7 / 38,1 48,8 / 50,7 58,4 / 60,5 73,4 / 75,6
Heating capacity (nominal) EWYQ - BAWN / BAWP kW 16,2 / 17,0 20,3 / 21,3 24,6 / 25,7 30,7 / 32,1 41,6 / 42,5 49,0 / 51,1 61,5 / 63,7
COP (nominal) EWAQ - BAWN / BAWP 2,93 / 2,97 2,86 / 2,86 2,76 / 2,75 2,90 / 2,89 2,90 / 2,89 2,78 / 2,76 2,97 / 2,94
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)% 130(1)/133(2) 126(1)/126(2) 130(1)/121(2) 120(1)/119(2) 126(1)/126(2) 138(1)/121(2) 121(1)/119(2)
SCOP 3,33(1)/3,39(2) 3,22(1)/3,22(2) 3,32(1)/3,09(2) 3,08(1)/3,06(2) 3,22(1)/3,21(2) 3,53(1)/3,08(2) 3,09(1)/3,04(2)
Seasonal space heating
eff . classA+(1)/A+(2) A+(1)/A+(2) A+(1)/A(2) A(1)/A(2) A+(1)/A+(2) A+(1)/A(2) A(1)/A(2)
Sound power level dB(A) 78 78 80 80 81 83 83
Options
OP10 Evaporator electric heater CZK 16.936,- 16.936,- 16.936,- 16.936,- 21.321,- 21.321,- 21.321,-
OPSP One centrifugal pump (low lift) CZK 18.855,- 18.855,- 18.855,- 25.048,- 25.048,- 25.048,- 25.048,-
OPHP One centrifugal pump (high lift) CZK 27.597,- 27.597,- 27.597,- 27.597,- 37.490,- 37.490,- 37.490,-
OPZL Low leaving water operation down to
-10 °CCZK 12.689,- 12.689,- 12.689,- 12.689,- 16.936,- 16.936,- 16.936,-
Kit
EKRP1AHT Demand PCB Remote:
On/Off , Cool/heat, thermo On/Off CZK 4.216,- 4.216,- 4.216,- 4.216,- 8.433,- 8.433,- 8.433,-
EKRUAHT Additional remote user interface CZK 7.016,- 7.016,- 7.016,- 7.016,- 7.016,- 7.016,- 7.016,-
BHGP26A1 Digital pressure gauges CZK 16.059,- 16.059,- 16.059,- 16.059,- 32.119,- 32.119,- 32.119,-
DTA104A62 External adaptor for:
Demand and Low noise control CZK 12.327,- 12.327,- 12.327,- 12.327,- 24.654,- 24.654,- 24.654,-
RTD-W Modbus interface CZK 10.426,- 10.426,- 10.426,- 10.426,- 10.426,- 10.426,- 10.426,-
EWAQ-BAW
Air cooled chiller inverter
High effi ciency with leader-of-class ESEER.
No buff er tank required for standard applications.
EWYQ-BAW
Air cooled heat pump Inverter
Wide operation range - ambient temperature in heating down to
-°C.
EWAQ-BAW, EWYQ-BAW
Unit size 20 32 40 64
Indoor unit 1× SEHVX20AAW 1× SEHVX32AAW 1× SEHVX40AAW 1× SEHVX64AAW
Outdoor Units 1× SERHQ020AAW1 1× SERHQ032AAW1 2× SERHQ020AAW1 2× SERHQ032AAW1
Refnet type - - KHRQ22M64T8 KHRQ22M75T8
Indoor unit Price per each CZK 122.884,- 137.354,- 144.013,- 146.617,-
Outdoor unit Price per each CZK 183.915,- 259.005,- 183.915,- 259.005,-
Refnet Price per each CZK - - 5.574,- 6.871,-
Unit Price per each (indoor + outdoor(s) + refnet)
CZK306.799,- 396.359,- 517.418,- 671.497,-
Cooling Capacity (nominal) kW 20,7 (1) 30,9 (1) 41,5 (1) 62,3 (1)
Cooling Capacity (maximum) kW 24,7 (1) 36,9 (1) 49,5 (1) 74,3 (1)
EER dB(A) 2,73 (1) 2,29 (1) 2,69 (1) 2,27 (1)
Heating Capacity (nominal) kW 21,3 (2)(3) 32,2 (2)(3) 42,5 (2)(3) 63,7 (2)(3)
Heating Capacity (maximum) kW 25,3 (2)(3) 38,1 (2)(3) 50,5 (2)(3) 75,7 (2)(3)
COP 3,48 (2) / 2,86 (3) 3,68 (2) / 2,89 (3) 3,54 (2) / 2,89 (3) 3,77 (2) / 2,94 (3)
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)
%126 119 126 120
SCOP 3,22 3,06 3,22 3,05
Seasonal space heating
eff . classA+ A A+ A
Sound power level (outdoor unit / each) dB(A) 78 dB(A) 80 dB(A) 78 dB(A) 80 dB(A)
Indoor unit connection (liquid / gas) 12,7 / 25,4 12,7 / 25,4 15,9 / 31,8 15,9 / 31,8
Standard Options SEHVX20AAW SEHVX32AAW SEHVX40AAW SEHVX64AAW
Standard Hydraulic package
One centrifugal pumpCZK including as standard including as standard including as standard including as standard
Kit SEHVX20AAW SEHVX32AAW SEHVX40AAW SEHVX64AAW
EKRP1AHTDemand PCB Remote:
On/Off , Cool/heat, thermo On/Off CZK 4.216,- 4.216,- 8.433,- 8.433,-
DTA104A62External adaptor for:
Demand and Low noise controlCZK 12.327,- 12.327,- 24.654,- 24.654,-
RTD-W Modbus interface CZK 10.426,- 10.426,- 10.426,- 10.426,-
EKCC*-W Cascade Control CZK 28.990,- 28.990,- 28.990,- 28.990,-
SEHVX-AAW
Air cooled heat pump inverter - split version
SEHVX-AAW, SERHQ-AAW1
Notes:
() Cooling: Ta °C - LWE °C (DT=°C), data according EN :
() Heating Ta DB/WB /°C - LWC°C (DT = °C), data according EN :
() Heating Ta DB/WB /°C - LWC°C
The prices colored in blue: pcs needed for size , ,
Note: () EWYQ-BAWN: Version without pump () EWYQ-BAWP: Version with pump; The prices colored in blue: pcs needed for size , ,
Note: The prices colored in blue pcs needed for size , ,
Applied Systems Price list -
Ou
tsid
e t
em
pe
ratu
re [
oC
]
50 cooling mode
40
30
20
10
0
-10
-20-15 -10 -5 0 5 10 15 20
Evaporator leaving water temperature [oC]
Ou
tsid
e t
em
pe
ratu
re [
oC
]
50 cooling mode
40
30
20
10
0
-10
-20-15 -10 -5 0 5 10 15 20
Evaporator leaving water temperature [oC]
Co
nd
en
ser
leav
ing
wa
ter
tem
pe
ratu
re [
°C] 55 heating mode
50
45
40
35
30
25
20-20 -15 -10 -5 0 5 10 15 20 25
Outside air tempeature [°C]
Air Cooled chiller EWAQ-G/ EWYQ-G
Product description:
› Compact Air Cooled chiller with Scroll compressors
› Refrigerant R410A
› Evaporator as plate heat exchanger
› Condenser as Microchannel heat exchanger
› Certified by Eurovent
› High efficiency rating – Eurovent rating Class A
› Reduced noise
› Electronic expansion valve
› Sequential control for Master/Slave function by default
› Partial heat recovery optionally available
› Total heat recovery optionally available
Operating limits, cooling only models:
Operating limits, heat pump models:
Standard equipment: › Main switch
› Master/Slave Control
› Direct start
› Ventilator speed control (phase modulation)
› Double setpoint value
› Evaporator electric heater
› Electronic expansion valve
› Operating hours counter
› Accumulative fault message
Ou
tsid
e t
em
pe
ratu
re [
oC
]
45 cooling mode
35
25
15
5
-5
-15-15 -10 -5 0 5 10 15 20
Evaporator leaving water temperature [oC]
part-load operation
EWAQ-G-SS
Standard effi ciency rating, standard noise level
Type of unit (rated power inaccordance with EN14511)
EWAQ075G-SS EWAQ085G-SS EWAQ100G-SS EWAQ110G-SS EWAQ120G-SS EWAQ140G-SS EWAQ155G-SS
Cooling capacity kW 74,7 84,2 96,7 107 117 139 154
Power input kW 27,7 31,2 35,0 39,5 43,4 51,1 57,2
Refrigerant circuit 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2
EER 2,70 2,70 2,76 35,0 2,76 2,73 2,7
ESEER 4,26 4,45 4,27 4,33 4,12 4,39 4,23
Length mm 2140 2680 2680 2680 3200 3200 3200
Width mm 1195 1195 1195 1195 1195 1195 1195
Height mm 1800 1800 1800 1800 1800 1800 1800
Weight of unit kg 681 792 953 923 982 1037 1066
Operating weight kg 692 802 963 934 993 1054 1085
Sound power dB(A) 83 85 87 89 89 89 89
Sound pressure (at 1m) dB(A) 66 68 69 71 71 71 71Buff er tank volume / option (OP 134/135/136/137)
liter 75 175 175 175 250 250 250
Price CZK 468.297,- 506.225,- 554.513,- 574.436,- 603.787,- 678.219,- 723.821,-Commissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Air Cooled chiller EWAQ-G
Code Type of unit EWAQ075G-SS EWAQ085G-SS EWAQ100G-SS EWAQ110G-SS EWAQ120G-SS EWAQ140G-SS EWAQ155G-SS
Mechanical
01aTotal heat recovery (including expansion card pol965)
CZK 79.803,- 79.803,- 80.187,- 87.285,- 87.285,- 87.285,- 91.916,-
03 Partial heat recovery CZK 28.857,- 28.857,- 28.857,- 29.433,- 29.433,- 34.448,- 34.448,-
08 Brine version CZK 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard
29 20mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
127 High and low pressure side manometers CZK 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,-
138 Condenser coil guard CZK 11.099,- 12.250,- 12.250,- 12.250,- 13.319,- 13.319,- 13.319,-
78 One centrifugal pump (low lift) CZK 56.262,- 59.962,- 59.962,- 59.962,- 62.620,- 66.622,- 66.622,-
79 One centrifugal pump (high lift) CZK 67.937,- 73.281,- 73.281,- 73.281,- 75.939,- 75.939,- 75.939,-
80 Two centrifugal pump (low lift) CZK 91.725,- 99.151,- 99.151,- 99.151,- 99.151,- 102.138,- 102.138,-
81 Two centrifugal pump (high lift) CZK 107.784,- 116.334,- 116.334,- 116.334,- 118.554,- 118.554,- 118.554,-
134 One centrifugal pump (low lift) + tank CZK 88.052,- 94.383,- 94.383,- 94.383,- 105.509,- 109.675,- 109.675,-
135 One centrifugal pump (high lift) + tank CZK 99.727,- 107.729,- 107.729,- 107.729,- 119.020,- 119.020,- 119.020,-
136 Two centrifugal pump (low lift) + tank CZK 140.588,- 146.973,- 146.973,- 146.973,- 148.754,- 150.974,- 150.974,-
137 Two centrifugal pump (high lift) + tank CZK 152.125,- 160.621,- 160.621,- 160.621,- 162.841,- 162.841,- 162.841,-
91 Double pressure relief valve with diverter CZK 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,-
139 E-coating microchannel coils CZK 20.883,- 30.776,- 30.776,- 30.776,- 40.231,- 40.231,- 40.231,-
115 Water fi lter CZK 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,-
Electrical / Control
04 Direct on line starter (dol) CZK Standard Standard Standard Standard Standard Standard Standard
06 Soft starter CZK 44.095,- 44.095,- 44.095,- 44.095,- 45.602,- 49.302,- 52.974,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control, setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,-
17 Capacitors for power factor correction CZK 16.991,- 16.991,- 16.991,- 16.991,- 16.991,- 18.909,- 22.198,-
57 Evaporator electric heater CZK Standard Standard Standard Standard Standard Standard Standard
58 Evaporator fl ow switch CZK 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard
67Ambient outside temperature sensor and setpoint reset
CZK Standard Standard Standard Standard Standard Standard Standard
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 7.810,- 8.112,- 8.441,- 8.441,- 8.441,- 9.592,- 10.661,-
96 Fans circuit breakers CZK 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,-
77 Spring anti vibration mounts CZK 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,-
83 External tank without cabinet (500 l) CZK 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,-
84 External tank without cabinet (1000 l) CZK 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,-
87 External tank with cabinet (500 l) CZK 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,-
88 External tank with cabinet (1000 l) CZK 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Optional accessories for chiller:
EWAQ G SS/SR – cooling only, standard effi ciency EWAQ G XS/XR – cooling only, high effi ciency
EWYQ G XS/XR – heat pump, high effi ciency EWYQ G XS/XR - heat pump, high effi ciency
Within this area
the fans speed
is increased for
reduced noise
version
Within this area
the fans speed
is increased for
reduced noise
version
Within this area
the fans speed
is increased for
reduced noise
version
-10°C reachable
thanks to
fan speed
modulation
provided as
standard
-10°C reachable
thanks to fan
speed modulation
provided as
standard
Operation with glycol
Operation with
glycol
Operation with
glycol
43 45
45
-3-17
Applied Systems Price list -
EWAQ-G-SR
Standard effi ciency rating, reduced noise level
Type of unit (rated power in accordance with EN14511)
EWAQ075G-SR EWAQ085G-SR EWAQ100G-SR EWAQ110G-SR EWAQ120G-SR EWAQ140G-SR EWAQ155G-SR
Cooling capacity kW 69,3 78,9 91,0 99,7 109 130 143
Power input kW 29,4 33,1 36,8 42,0 46,3 54,0 61,2
Refrigerant circuit 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2
EER 2,36 2,38 2,47 2,38 2,35 2,42 2,34
ESEER 3,94 4,12 3,94 4,02 3,74 4,12 3,88
Length mm 2140 2680 2680 2680 3200 3200 3200
Width mm 1195 1195 1195 1195 1195 1195 1195
Height mm 1800 1800 1800 1800 1800 1800 1800
Weight of unit kg 711 822 983 953 1012 1067 1096
Operating weight kg 722 832 993 963 1023 1084 1115
Sound power dB(A) 79 82 84 86 86 86 86
Sound pressure (at 1m) dB(A) 62 65 66 68 68 68 68Buff er tank volume / option (OP 134/135/136/137)
liter 75 175 175 175 250 250 250
Price CZK 501.155,- 541.769,- 593.400,- 614.722,- 646.100,- 725.712,- 774.575,-Commissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:
Code Type of unit EWAQ075G-SR EWAQ085G-SR EWAQ100G-SR EWAQ110G-SR EWAQ120G-SR EWAQ140G-SR EWAQ155G-SR
Mechanical
01ATotal heat recovery (including expansion card pol965)
CZK 79.803,- 79.803,- 80.187,- 87.285,- 87.285,- 87.285,- 91.916,-
03 Partial heat recovery CZK 28.857,- 28.857,- 28.857,- 29.433,- 29.433,- 34.448,- 34.448,-
08 Brine version CZK 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard
29 20Mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard
126 CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
127High and low pressure side manometers
CZK 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,-
138 Condenser coil guard CZK 11.099,- 12.250,- 12.250,- 12.250,- 13.319,- 13.319,- 13.319,-
78 One centrifugal pump (low lift) CZK 56.262,- 59.962,- 59.962,- 59.962,- 62.620,- 66.622,- 66.622,-
79 One centrifugal pump (high lift) CZK 67.937,- 73.281,- 73.281,- 73.281,- 75.939,- 75.939,- 75.939,-
80 Two centrifugal pump (low lift) CZK 91.725,- 99.151,- 99.151,- 99.151,- 99.151,- 102.138,- 102.138,-
81 Two centrifugal pump (high lift) CZK 107.784,- 116.334,- 116.334,- 116.334,- 118.554,- 118.554,- 118.554,-
134 One centrifugal pump (low lift) + tank CZK 88.052,- 94.383,- 94.383,- 94.383,- 105.509,- 109.675,- 109.675,-
135 One centrifugal pump (high lift) + tank CZK 99.727,- 107.729,- 107.729,- 107.729,- 119.020,- 119.020,- 119.020,-
136 Two centrifugal pump (low lift) + tank CZK 140.588,- 146.973,- 146.973,- 146.973,- 148.754,- 150.974,- 150.974,-
137 Two centrifugal pump (high lift) + tank CZK 152.125,- 160.621,- 160.621,- 160.621,- 162.841,- 162.841,- 162.841,-
91Double pressure relief valve with diverter
CZK 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,-
139 E-coating microchannel coils CZK 20.883,- 30.776,- 30.776,- 30.776,- 40.231,- 40.231,- 40.231,-
115 Water fi lter CZK 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,-
Electrical / control
04 Direct on line starter (dol) CZK Standard Standard Standard Standard Standard Standard Standard
06 Soft starter CZK 44.095,- 44.095,- 44.095,- 44.095,- 45.602,- 49.302,- 52.974,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard
15A
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,-
17 Capacitors for power factor correction CZK 16.991,- 16.991,- 16.991,- 16.991,- 16.991,- 18.909,- 22.198,-
57 Evaporator electric heater CZK Standard Standard Standard Standard Standard Standard Standard
58 Evaporator fl ow switch CZK 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard
67Ambient outside temperature sensor and setpoint reset
CZK Standard Standard Standard Standard Standard Standard Standard
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 7.810,- 8.112,- 8.441,- 8.441,- 8.441,- 9.592,- 10.661,-
96 Fans circuit breakers CZK 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,-
77 Spring anti vibration mounts CZK 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,-
83 External tank without cabinet (500 l) CZK 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,-
84 External tank without cabinet (1000 l) CZK 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,-
87 External tank with cabinet (500 l) CZK 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,-
88 External tank with cabinet (1000 l) CZK 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Air Cooled chiller EWAQ-G
EWAQ-G-XS
High effi ciency rating, standard noise level
Type of unit (rated power inaccordance with EN14511)
EWAQ080G-XS EWAQ090G-XS EWAQ105G-XS EWAQ115G-XS EWAQ130G-XS EWAQ150G-XS
Cooling capacity kW 79,8 90,3 105 117 131 149
Power input kW 25,8 29,0 33,8 37,7 42,3 48,1
Refrigerant circuit 1 1 1 1 1 1
Compressors 2 2 2 2 2 2
EER 3,10 3,11 3,12 3,10 3,10 3,10
ESEER 4,2 4,3 4,28 4,34 4,22 4,36
Length mm 2680 3200 3200 3200 3800 3800
Width mm 1195 1195 1195 1195 1195 1195
Height mm 1800 1800 1800 1800 1820 1820
Weight of unit kg 734 850 1020 991 1086 1123
Operating weight kg 744 860 1035 1007 1102 1144
Sound power dB(A) 84 85 87 89 89 89
Sound pressure (at 1m) dB(A) 66 68 69 71 71 71Buff er tank volume / option (OP 134/135/136/137)
liter 75 175 175 175 250 250
Price CZK 580.959,- 624.149,- 678.082,- 714.311,- 773.122,- 829.193,-Commissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:
Code Type of unit EWAQ080G-XS EWAQ090G-XS EWAQ105G-XS EWAQ115G-XS EWAQ130G-XS EWAQ150G-XS
Mechanical
01aTotal heat recovery (including expansion card pol965)
CZK 79.803,- 79.803,- 80.187,- 87.285,- 87.285,- 87.285,-
03 Partial heat recovery CZK 28.857,- 28.857,- 28.857,- 29.433,- 29.433,- 34.448,-
08 Brine version CZK 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard
29 20Mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
127High and low pressure side manometers
CZK 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,-
138 Condenser coil guard CZK 12.250,- 13.319,- 13.319,- 13.319,- 16.690,- 16.690,-
78 One centrifugal pump (low lift) CZK 59.962,- 62.620,- 62.620,- 62.620,- 69.280,- 69.280,-
79 One centrifugal pump (high lift) CZK 73.281,- 75.939,- 75.939,- 75.939,- 80.817,- 80.817,-
80 Two centrifugal pump (low lift) CZK 99.151,- 99.151,- 99.151,- 99.151,- 106.140,- 106.140,-
81 Two centrifugal pump (high lift) CZK 116.334,- 118.554,- 118.554,- 118.554,- 121.925,- 121.925,-
134 One centrifugal pump (low lift) + tank CZK 94.383,- 105.509,- 105.509,- 105.509,- 112.169,- 112.169,-
135 One centrifugal pump (high lift) + tank CZK 107.729,- 119.020,- 119.020,- 119.020,- 123.898,- 123.898,-
136 Two centrifugal pump (low lift) + tank CZK 146.973,- 148.754,- 148.754,- 148.754,- 153.906,- 153.906,-
137 Two centrifugal pump (high lift) + tank CZK 160.621,- 162.841,- 162.841,- 162.841,- 165.444,- 167.664,-
91Double pressure relief valve with diverter
CZK 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,-
139 E-coating microchannel coils CZK 30.776,- 40.231,- 40.231,- 40.231,- 51.056,- 51.056,-
115 Water fi lter CZK 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,-
Electrical / Control
04 Direct on line starter (dol) CZK Standard Standard Standard Standard Standard Standard
06 Soft starter CZK 44.095,- 44.095,- 44.095,- 44.095,- 45.602,- 49.302,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,-
17 Capacitors for power factor correction CZK 16.991,- 16.991,- 16.991,- 16.991,- 16.991,- 18.909,-
57 Evaporator electric heater CZK Standard Standard Standard Standard Standard Standard
58 Evaporator fl ow switch CZK 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard
67Ambient outside temperature sensor and setpoint reset
CZK Standard Standard Standard Standard Standard Standard
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 7.810,- 8.112,- 8.441,- 8.441,- 8.441,- 9.592,-
96 Fans circuit breakers CZK 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,-
77 Spring anti vibration mounts CZK 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,-
83 External tank without cabinet (500 l) CZK 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,-
84 External tank without cabinet (1000 l) CZK 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,-
87 External tank with cabinet (500 l) CZK 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,-
88 External tank with cabinet (1000 l) CZK 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Air Cooled chiller EWAQ-G
Applied Systems Price list -
EWAQ-G-XR
High effi ciency rating, reduced noise level
Type of unit (rated power in accordance with EN14511)
EWAQ080G-XR EWAQ090G-XR EWAQ105G-XR EWAQ115G-XR EWAQ130G-XR EWAQ150G-XR
Cooling capacity kW 76,0 86,0 100 110 125 141
Power input kW 26,4 29,9 34,7 39,0 43,3 49,8
Refrigerant circuit 1 1 1 1 1 1
Compressors 2 2 2 2 2 2
EER 2,88 2,88 2,89 2,83 2,88 2,83
ESEER 4,18 4,29 4,27 4,21 4,31 4,33
Length mm 2860 3200 3200 3200 3800 3800
Width mm 1195 1195 1195 1195 1195 1195
Height mm 1800 1800 1800 1800 1820 1820
Weight of unit kg 764 880 1050 1021 1116 1153
Operating weight kg 774 890 1065 1037 1132 1174
Sound power dB(A) 80 82 84 86 86 86
Sound pressure (at 1m) dB(A) 62 65 66 68 67 67
Buff er tank volume / option (OP 134/135/136/137)
liter 75 175 175 175 250 250
Price CZK 613.817,- 659.693,- 716.970,- 754.597,- 815.436,- 876.713,-
Commissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:
Code Type of unit EWAQ080G-XR EWAQ090G-XR EWAQ105G-XR EWAQ115G-XR EWAQ130G-XR EWAQ150G-XR
Mechanical
01aTotal heat recovery (including expansion card pol965)
CZK 79.803,- 79.803,- 80.187,- 87.285,- 87.285,- 87.285,-
03 Partial heat recovery CZK 28.857,- 28.857,- 28.857,- 29.433,- 29.433,- 34.448,-
08 Brine version CZK 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard
29 20mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
127 High and low pressure side manometers CZK 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,-
138 Condenser coil guard CZK 12.250,- 13.319,- 13.319,- 13.319,- 16.690,- 16.690,-
78 One centrifugal pump (low lift) CZK 59.962,- 62.620,- 62.620,- 62.620,- 69.280,- 69.280,-
79 One centrifugal pump (high lift) CZK 73.281,- 75.939,- 75.939,- 75.939,- 80.817,- 80.817,-
80 Two centrifugal pump (low lift) CZK 99.151,- 99.151,- 99.151,- 99.151,- 106.140,- 106.140,-
81 Two centrifugal pump (high lift) CZK 116.334,- 118.554,- 118.554,- 118.554,- 121.925,- 121.925,-
134 One centrifugal pump (low lift) + tank CZK 94.383,- 105.509,- 105.509,- 105.509,- 112.169,- 112.169,-
135 One centrifugal pump (high lift) + tank CZK 107.729,- 119.020,- 119.020,- 119.020,- 123.898,- 123.898,-
136 Two centrifugal pump (low lift) + tank CZK 146.973,- 148.754,- 148.754,- 148.754,- 153.906,- 153.906,-
137 Two centrifugal pump (high lift) + tank CZK 160.621,- 162.841,- 162.841,- 162.841,- 165.444,- 167.664,-
91 Double pressure relief valve with diverter CZK 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,-
139 E-coating microchannel coils CZK 30.776,- 40.231,- 40.231,- 40.231,- 51.056,- 51.056,-
115 Water fi lter CZK 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,-
Electrical / Control
04 Direct on line starter (dol) CZK Standard Standard Standard Standard Standard Standard
06 Soft starter CZK 44.095,- 44.095,- 44.095,- 44.095,- 45.602,- 49.302,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,-
17 Capacitors for power factor correction CZK 16.991,- 16.991,- 16.991,- 16.991,- 16.991,- 18.909,-
57 Evaporator electric heater CZK Standard Standard Standard Standard Standard Standard
58 Evaporator fl ow switch CZK 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard
67Ambient outside temperature sensor and setpoint reset
CZK Standard Standard Standard Standard Standard Standard
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 7.810,- 8.112,- 8.441,- 8.441,- 8.441,- 9.592,-
96 Fans circuit breakers CZK 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,-
77 Spring anti vibration mounts CZK 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,-
83 External tank without cabinet (500 l) CZK 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,-
84 External tank without cabinet (1000 l) CZK 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,-
87 External tank with cabinet (500 l) CZK 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,-
88 External tank with cabinet (1000 l) CZK 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Air Cooled chiller EWAQ-G
EWYQ-G-XS
High effi ciency rating, standard noise level
Type of unit (rated power in accordance with EN14511)
EWYQ075G-XS EWYQ085G-XS EWYQ100G-XS EWYQ110G-XS EWYQ120G-XS EWYQ140G-XS EWYQ160G-XS
Cooling capacity kW 77,8 88,1 101 117 127 147 165
Power input (cooling) kW 27,0 31,5 36,0 39,5 44,7 50,2 57,8
Heating capacity kW 82,2 91,2 110 127 138 156 170
Power input (heating) kW 26,0 29,0 34,0 39,0 43,0 50,0 54,0
Refrigerant circuit 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2
EER 2,88 2,80 2,81 2,97 2,84 2,92 2,85
ESEER 3,9 3,94 3,97 4,03 3,92 3,96 3,96
COP 3,14 3,12 3,24 3,25 3,2 3,11 3,13
Length x Width x Height mm 2826 x 1195 x 1800 3426 x 1195 x 1800 4026 x 1195 x 1800
Weight of unit / Operating weight kg 850 / 858 912 / 921 1077 / 1088 1183 / 1194 1213 / 1224 1333 / 1344 1394 / 1411Space heating
Average climate wateroutlet 35°C
General ηs (Seasonal space heating effi ciency)
%131 129 142 140 142 138 140
SCOP 3,35 3,31 3,62 3,58 3,63 3,53 3,58
Sound power dB(A) 84 85 87 89 89 89 89
Sound pressure (at 1m) dB(A) 66 68 70 71 71 71 71Buff er tank volume / option (OP 134/135/136/137)
liter 75 175 175 175 250 250 250
Price CZK 576.081,- 632.672,- 702.390,- 766.134,- 808.256,- 889.320,- 956.517,-
Commissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:
Code Type of unit EWYQ075G-XS EWYQ085G-XS EWYQ100G-XS EWYQ110G-XS EWYQ120G-XS EWYQ140G-XS EWYQ160G-XS
Mechanical
03 Partial heat recovery CZK 28.857,- 28.857,- 28.857,- 29.433,- 29.433,- 34.448,- 34.448,-
08 Brine version CZK 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard
29 20mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
127 High and low pressure side manometers CZK 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,-
138 Condenser coil guard CZK 12.250,- 12.250,- 12.250,- 13.319,- 13.319,- 16.690,- 16.690,-
78 One centrifugal pump (low lift) CZK 59.962,- 59.962,- 59.962,- 62.620,- 62.620,- 69.280,- 69.280,-
79 One centrifugal pump (high lift) CZK 73.281,- 73.281,- 73.281,- 75.939,- 75.939,- 80.817,- 80.817,-
80 Two centrifugal pump (low lift) CZK 99.151,- 99.151,- 99.151,- 99.151,- 99.151,- 106.140,- 106.140,-
81 Two centrifugal pump (high lift) CZK 116.334,- 116.334,- 116.334,- 118.554,- 118.554,- 121.925,- 121.925,-
134 One centrifugal pump (low lift) + tank CZK 94.383,- 94.383,- 94.383,- 105.509,- 105.509,- 112.169,- 112.169,-
135 One centrifugal pump (high lift) + tank CZK 107.729,- 107.729,- 107.729,- 119.020,- 119.020,- 123.898,- 123.898,-
136 Two centrifugal pump (low lift) + tank CZK 146.973,- 146.973,- 146.973,- 148.754,- 148.754,- 153.906,- 153.906,-
137 Two centrifugal pump (high lift) + tank CZK 160.621,- 160.621,- 160.621,- 162.841,- 162.841,- 167.664,- 167.664,-
91 Double pressure relief valve with diverter CZK 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,-
115 Water fi lter CZK 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,-
49 Alucoat fi ns coil CZK Standard Standard Standard Standard Standard Standard Standard
114 Nordic kit CZK 24.418,- 24.418,- 24.418,- 28.857,- 28.857,- 33.297,- 33.297,-
Electrical / Control
04 Direct on line starter (dol) CZK Standard Standard Standard Standard Standard Standard Standard
06 Soft starter CZK 44.095,- 44.095,- 44.095,- 44.095,- 45.602,- 49.302,- 52.974,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,-
17 Capacitors for power factor correction CZK 16.991,- 16.991,- 16.991,- 16.991,- 16.991,- 18.909,- 22.198,-
57 Evaporator electric heater CZK Standard Standard Standard Standard Standard Standard Standard
58 Evaporator fl ow switch CZK 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard
67Ambient outside temperature sensor and setpoint reset
CZK Standard Standard Standard Standard Standard Standard Standard
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 7.810,- 8.112,- 8.441,- 8.441,- 8.441,- 9.592,- 10.661,-
96 Fans circuit breakers CZK 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,-
77 Spring anti vibration mounts CZK 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,-
83 External tank without cabinet (500 l) CZK 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,-
84 External tank without cabinet (1000 l) CZK 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,-
87 External tank with cabinet (500 l) CZK 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,-
88 External tank with cabinet (1000 l) CZK 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Air Cooled chiller EWYQ-G (heat pump)
Applied Systems Price list -
EWYQ-G-XR
High effi ciency rating, reduced noise level
Type of unit (rated power in accordance with EN14511)
EWYQ075G-XR EWYQ085G-XR EWYQ100G-XR EWYQ110G-XR EWYQ120G-XR EWYQ140G-XR EWYQ160G-XR
Cooling capacity kW 75,2 84,5 95 111 120 139 155
Power input kW 27,7 32,7 38,6 41,5 47,4 52,8 61,5
Heating capacity kW 82,2 91,2 110 127 138 156 170
Power input (heating) kW 26 29 34 39 43 50 54
Refrigerant circuit 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2
EER 2,71 2,59 2,46 2,68 2,52 2,64 2,51
ESEER 3,85 3,9 3,79 3,92 3,76 3,86 3,79
COP 3,14 3,12 3,24 3,25 3,2 3,11 3,13
Length x Width x Height mm 2826 x 1195 x 1800 3426 x 1195 x 1800 4026 x 1195 x 1800
Weight of unit kg 880 942 1107 1233 1243 1363 1424
Operating weight kg 888 951 1118 1224 1254 1374 1441Space heating
Average climate wateroutlet 35°C
General ηs (Seasonal space heating effi ciency
%131 129 142 140 142 138 140
SCOP 3,35 3,31 3,62 3,58 3,63 3,53 3,58
Sound power dB(A) 80 82 84 86 86 86 86
Sound pressure (at 1m) dB(A) 62 65 66 68 68 67 67Buff er tank volume / option (OP 134/135/136/137)
liter 75 175 175 175 250 250 250
Price CZK 608.939,- 668.189,- 741.278,- 806.420,- 850.569,- 936.840,- 1.004.037,-Commissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:Code Type of unit EWYQ075G-XR EWYQ085G-XR EWYQ100G-XR EWYQ110G-XR EWYQ120G-XR EWYQ140G-XR EWYQ160G-XR
Mechanical
03 Partial heat recovery CZK 28.857,- 28.857,- 28.857,- 29.433,- 29.433,- 34.448,- 34.448,-
08 Brine version CZK 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,- 12.250,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard
29 20mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
127 High and low pressure side manometers CZK 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,- 6.659,-
138 Condenser coil guard CZK 12.250,- 12.250,- 12.250,- 13.319,- 13.319,- 16.690,- 16.690,-
78 One centrifugal pump (low lift) CZK 59.962,- 59.962,- 59.962,- 62.620,- 62.620,- 69.280,- 69.280,-
79 One centrifugal pump (high lift) CZK 73.281,- 73.281,- 73.281,- 75.939,- 75.939,- 80.817,- 80.817,-
80 Two centrifugal pump (low lift) CZK 99.151,- 99.151,- 99.151,- 99.151,- 99.151,- 106.140,- 106.140,-
81 Two centrifugal pump (high lift) CZK 116.334,- 116.334,- 116.334,- 118.554,- 118.554,- 121.925,- 121.925,-
134 One centrifugal pump (low lift) + tank CZK 94.383,- 94.383,- 94.383,- 105.509,- 105.509,- 112.169,- 112.169,-
135 One centrifugal pump (high lift) + tank CZK 107.729,- 107.729,- 107.729,- 119.020,- 119.020,- 123.898,- 123.898,-
136 Two centrifugal pump (low lift) + tank CZK 146.973,- 146.973,- 146.973,- 148.754,- 148.754,- 153.906,- 153.906,-
137 Two centrifugal pump (high lift) + tank CZK 160.621,- 160.621,- 160.621,- 162.841,- 162.841,- 167.664,- 167.664,-
91 Double pressure relief valve with diverter CZK 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,- 24.418,-
115 Water fi lter CZK 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,- 12.826,-
49 Alucoat fi ns coil CZK Standard Standard Standard Standard Standard Standard Standard
114 Nordic kit CZK 24.418,- 24.418,- 24.418,- 28.857,- 28.857,- 33.297,- 33.297,-
Electrical / Control
04 Direct on line starter (dol) CZK Standard Standard Standard Standard Standard Standard Standard
06 Soft starter CZK 44.095,- 44.095,- 44.095,- 44.095,- 45.602,- 49.302,- 52.974,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,- 10.030,-
17 Capacitors for power factor correction CZK 16.991,- 16.991,- 16.991,- 16.991,- 16.991,- 18.909,- 22.198,-
57 Evaporator electric heater CZK Standard Standard Standard Standard Standard Standard Standard
58 Evaporator fl ow switch CZK 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,- 5.782,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard
67Ambient outside temperature sensor and setpoint reset
CZK Standard Standard Standard Standard Standard Standard Standard
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 7.810,- 8.112,- 8.441,- 8.441,- 8.441,- 9.592,- 10.661,-
96 Fans circuit breakers CZK 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,- 4.440,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,- 10.085,-
77 Spring anti vibration mounts CZK 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,- 31.653,-
83 External tank without cabinet (500 l) CZK 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,- 78.022,-
84 External tank without cabinet (1000 l) CZK 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,- 104.166,-
87 External tank with cabinet (500 l) CZK 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,- 114.827,-
88 External tank with cabinet (1000 l) CZK 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,- 147.110,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Air Cooled chiller EWYQ-G (heat pump)
EWWP-KBW1N
Water cooled chiller
Unit size EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N
Price CZK 119.020,- 151.413,- 174.268,- 195.124,-
Cooling capacity kW 12,9 21,4 27,8 32,3
EER 3,44 3,49 3,54 3,54
Heat rejection capacity kW 16,7 27,5 35,6 41,5
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)
%107 106 115 116
SCOP 2,88 2,86 3,08 3,11
Seasonal space heating
eff . classA+ A+ A+ A+
Average
climate
water outlet
55°C
General ηs (Seasonal space
heating effi ciency)
%132 134 138 143
SCOP 3,49 3,55 3,66 3,78
Seasonal space heating
eff . classA+ A+ A+ A+
Sound power level dB(A) 64 64 64 71
Options
OPZH glycol application to -5 °C LWE CZK 5.974,- 5.974,- 5.974,- 5.974,-
OPZL glycol application to -10 °C LWE CZK 5.974,- 5.974,- 5.974,- 5.974,-
Kit
EKLS1 low noise kit 5 HP CZK 8.304,- – – –
EKLS2 low noise kit 8/10/12 HP CZK – 8.304,- 8.304,- 8.304,-
EKAC10C BMS address card CZK 4.714,- 4.714,- 4.714,- 4.714,-
EKRUMCA remote user interface CZK 8.742,- 8.742,- 8.742,- 8.742,-
EHMC10A10 hydraulic module CZK 89.066,- 89.066,- 89.066,- –
EHMC10A80 hydraulic module – pump size up CZK 94.712,- 94.712,- 94.712,- –
EHMC15A10 hydraulic module CZK – – 94.712,- 94.712,-
EHMC15A80 hydraulic module – pump size up CZK – – 98.822,- 98.822,-
EKSSsoft starter (requested Q’ty as per number
of compressor(s) of the unit)CZK on request on request on request on request
Unit size EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N
Price CZK 243.603,- 288.904,- 320.310,-
Cooling capacity kW 42,8 55,7 64,7
EER 3,51 3,48 3,55
Heat rejection capacity kW 55,0 71,7 83
Space
heating
Average
climate
water outlet
35°C
General ηs (Seasonal space
heating effi ciency)
%102 109 113
SCOP 2,75 2,91 3,03
Seasonal space heating
eff . classA+ A+ A+
Average
climate
water outlet
55°C
General ηs (Seasonal space
heating effi ciency)
%136 139 142
SCOP 3,59 3,66 3,74
Seasonal space heating
eff . classA+ A+ A+
Sound power level dB(A) 67 67 74
Options
OPZH glycol application to -5 °C LWE CZK 5.974,- 5.974,- 5.974,-
OPZL glycol application to -10 °C LWE CZK 5.974,- 5.974,- 5.974,-
Kit
EKLS2 low noise kit 8/10/12 HP (2 pcs.) CZK 8.304,- 8.304,- 8.304,-
EKAC10C BMS address card CZK 4.714,- 4.714,- 4.714,-
EKRUMCA remote user interface CZK 8.742,- 8.742,- 8.742,-
EHMC15A10 hydraulic module CZK 94.712,- – –
EHMC15A80 hydraulic module – pump size up CZK 98.822,- – –
EHMC30A10 hydraulic module CZK 106.359,- 106.359,- 106.359,-
EHMC30A80 hydraulic module – pump size up CZK 106.359,- 106.359,- 106.359,-
EKSSsoft starter (requested Q’ty as per number
of compressor(s) of the unit)on request on request on request
Note: EKACC is needed for direct BMS connection via Modbus
EKACC is needed to install EKRUMCA
EWWP-KBW1N
Applied Systems Price list -
EWWP-KAW1M
Water cooled chiller
Capacity index 090 100 110 120
Basic modelEWWP045KAW1M
EWWP045KAW1M
EWWP045KAW1M
EWWP055KAW1M
EWWP055KAW1M
EWWP055KAW1M
EWWP055KAW1M
EWWP065KAW1M
Control box ECB2MUW ECB2MUW ECB2MUW ECB2MUW
Price CZK 447.174,- 496.778,- 546.381,- 578.801,-
Cooling capacity kW 85,7 98,6 112 121
Sound power level dB(A) 71 71 71 75
Options
OPZH glycol application to -5°C LWE CZK 11.949,- 11.949,- 11.949,- 11.949,-
OPZL glycol application to -10°C LWE CZK 11.949,- 11.949,- 11.949,- 11.949,-
Kit
EKSSsoft starter (requested Q’ty as per
number of compressor(s) of the unit)CZK on request on request on request on request
Capacity index 130 145 155 165
Basic modelEWWP065KAW1M
EWWP065KAW1M
EWWP045KAW1M
EWWP045KAW1M
EWWP055KAW1M
EWWP045KAW1M
EWWP055KAW1M
EWWP055KAW1M
EWWP055KAW1M
EWWP055KAW1M
EWWP055KAW1M
Control box ECB2MUW ECB3MUW ECB3MUW ECB3MUW
Price CZK 611.221,- 679.925,- 729.528,- 779.131,-
Cooling capacity kW 130 141 154 167
Sound power level dB(A) 77 73 73 73
Options
OPZH glycol application to -5°C LWE CZK 11.949,- 11.949,- 11.949,- 11.949,-
OPZL glycol application to -10°C LWE CZK 11.949,- 11.949,- 11.949,- 11.949,-
Kit
EKSSsoft starter (requested Q’ty as per
number of compressor(s) of the unit)CZK on request on request on request on request
Capacity index 175 185 195
Basic model
EWWP055KAW1M
EWWP055KAW1M
EWWP065KAW1M
EWWP055KAW1M
EWWP065KAW1M
EWWP065KAW1M
EWWP065KAW1M
EWWP065KAW1M
EWWP065KAW1M
Control box ECB3MUW ECB3MUW ECB3MUW
Price CZK 811.551,- 843.971,- 876.392,-
Cooling capacity kW 176 185 194
Sound power level dB(A) 76 78 79
Options
OPZH glycol application to -5°C LWE CZK 17.923,- 17.923,- 17.923,-
OPZL glycol application to -10°C LWE CZK 17.923,- 17.923,- 17.923,-
Kit
EKSSsoft starter (requested Q’ty as per
number of compressor(s) of the unit)CZK on request on request on request
EWWP-KAW1M Water/Water Chiller EWW(H)Q-G(L)-SS
Product description:
› Compact Water/Water Chiller with Scroll compressors
› Refrigerant R410A
› Evaporator as plate heat exchanger
› Condenser as plate heat exchanger
› Certified by Eurovent
› High efficiency rating – Eurovent rating Class A
› Electronic expansion valve
› Sequential control for Master/Slave function as standard feature
› Partial heat recovery optionally available
› Soundproof enclosure (Sound Proof System) optionally available
› Installed pump optionally available
Operating limits (cooling only): Condenser outlet temperature: +25°C to + 55°C
Evaporator outlet temperature: -10°C to + 15°C
Standard equipment › Main switch
› Direct start
› Double setpoint value
› Evaporator electric heater
› Electronic expansion valve
› Evaporator insulation 20 mm
› Accumulative fault message
con
de
nse
r le
av
ing
wa
ter
tem
pe
ratu
re
(co
nd
en
ser
ou
tle
t te
mp
era
ture
) [o
C]
60 operating limits
55
50
45
40
35
30
25
20
-11 -8 -5 -2 1 4 7 10 13 16
Evaporator leaving water temperature [oC]
Operation with glycol
Applied Systems Price list -
EWWQ-G-SS
One refrigerant circuit, standard effi ciency rating
Type of unit (rated power in accordance with EN14511)
EWWQ090G-SS EWWQ100G-SS EWWQ120G-SS EWWQ130G-SS EWWQ150G-SS EWWQ170G-SS EWWQ190G-SS EWWQ210G-SS EWWQ240G-SS EWWQ300G-SS EWWQ360G-SS
Cooling capacity kW 93,7 106 119 136 150 172 194 221 246 314 370
Power input kW 21,3 24 26,9 30,5 33,9 38,9 43,8 51,2 56,6 70,2 84
Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2 2 2 2 2
EER 4,4 4,4 4,42 4,46 4,42 4,42 4,42 4,31 4,34 4,48 4,41
ESEER 5,51 5,52 5,51 5,53 5,51 5,53 5,52 5,52 5,52 5,52 5,52
Length x Width x Height mm 2.432 x 928 x 1.066 2.264 x 928 x 1.066 2.432 x 928 x 1.066 2.432 x 928 x 1.186
Weight of unit kg 516 606 728 762 795 832 871 921 934 1.083 1.181
Operating weight kg 555 652 782 821 859 901 946 1.010 1.023 1.195 1.311Space heating
Average climate wateroutlet 35°C
General ηs (Seasonal space heating effi ciency)
% 163 163 165 168 168 168 167 164 162 166 -
SCOP 4,28 4,28 4,33 4,40 4,39 4,40 4,38 4,29 4,25 4,34 -
Sound power dB(A) 80 83 85 87 88 88 88 90 92 93 93
Sound pressure (at 1m) dB(A) 64 67 69 70 72 72 72 74 76 76 77
Price CZK 480.108,- 512.062,- 546.702,- 583.562,- 617.435,- 677.452,- 731.001,- 747.471,- 799.157,- 966.821,- 1.102.174,-
Commissioning chillerCommissioning by DAIKIN service (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:
Code Type of unit EWWQ090G-SS EWWQ100G-SS EWWQ120G-SS EWWQ130G-SS EWWQ150G-SS EWWQ170G-SS EWWQ190G-SS EWWQ210G-SS EWWQ240G-SS EWWQ300G-SS EWWQ360G-SS
Mechanical
07aHeat pump version (with reversibility on water side)
CZK 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,-
133 Stacked installation CZK 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,-
08 Brine version CZK 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,-
03 Partial heat recovery CZK 30.502,- 30.502,- 30.502,- 30.968,- 31.159,- 36.421,- 37.490,- 39.902,- 47.191,- 49.932,- 53.166,-
130 Evaporator and condenser victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
29 20Mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
33 20Mm condenser insulation CZK 4.686,- 4.686,- 4.686,- 4.686,- 4.686,- 4.686,- 4.686,- 4.686,- 4.686,- 4.686,- 4.686,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,-
127 High and low pressure side manometers CZK 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,-
76-c Sound proof system (compressors jacket) CZK 24.747,- 22.390,- 20.170,- 20.170,- 20.170,- 20.170,- 20.170,- Not available Not available Not available Not available
76-b Sound proof system (compressor) CZK 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,-
91Double pressure relief valve with diverter
CZK 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,-
115 Water fi lter CZK 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 21.239,-
122 Evaporator single pump (low lift) CZK 31.516,- 31.516,- 33.571,- 33.571,- 33.571,- 55.632,- 55.632,- 55.632,- 55.632,- 55.632,- 51.631,-
123 Evaporator single pump (high lift) CZK 36.229,- 36.229,- 38.559,- 38.559,- 38.559,- 64.018,- 64.018,- 64.018,- 64.018,- 64.018,- 59.387,-
124 Condenser single pump (low lift) CZK 37.819,- 37.819,- 40.231,- 40.231,- 40.231,- 66.813,- 66.813,- 66.813,- 66.813,- 66.813,- 61.990,-
125 Condenser single pump (high lift) CZK 43.519,- 43.519,- 46.260,- 46.260,- 46.260,- 76.816,- 76.816,- 76.816,- 76.816,- 76.816,- 71.253,-
Electrical / Control
04 Dol starter CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Not available Not available
132 Part winidng start CZK Not available Not available Not available Not available Not available Not available Not available Not available Not available Standard Standard
06 Soft starter CZK 73.336,- 66.813,- 60.318,- 64.648,- 68.951,- 74.021,- 79.118,- 84.106,- 86.216,- Not available Not available
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Not available Not available
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,-
17 Capacitors for power factor correction CZK 19.677,- 19.677,- 19.677,- 19.677,- 19.677,- 19.677,- 34.777,- 34.777,- 34.777,- 48.589,- 48.589,-
58 Evaporator fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
59 Condenser fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 8.249,- 8.578,- 8.934,- 8.934,- 8.934,- 10.085,- 11.291,- 11.729,- 12.168,- 41.436,- 70.677,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
102 Ground fault relay CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Water/Water Chiller EWW(H)Q-G(L)-SS
EWHQ-G-SS (heat pump)
One refrigerant circuit, standard effi ciency ratingWith reversible refrigerant circuit
Type of unit (rated power in accordance with EN14511)
EWHQ100G-SS EWHQ120G-SS EWHQ130G-SS EWHQ150G-SS EWHQ160G-SS EWHQ190G-SS EWHQ210G-SS EWHQ240G-SS EWHQ270G-SS EWHQ340G-SS EWHQ400G-SS
Cooling capacity kW 87,3 100 111 127 141 160 181 208 232 291 352
Power input kW 22,4 25,3 28,5 32,0 35,6 41,1 46,0 53,3 59,1 73,7 88,4
Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2 2 2 2 2
EER 3,90 3,95 3,91 3,96 3,95 3,90 3,93 3,90 3,92 3,95 3,98
ESEER 4,70 4,84 4,65 4,86 4,80 4,89 4,86 4,83 4,79 4,90 4,83
Length mm 2.432 2.432 2.264 2.264 2.264 2.432 2.432 2.432 2.432 2.432 2.432
Width mm 928 928 928 928 928 928 928 928 928 928 928
Height mm 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.186 1.186
Weight of unit kg 519 608 728 770 808 838 880 930 941 1.090 1.203
Operating weight kg 558 654 782 830 873 908 955 1.019 1.031 1.202 1.334Space heating
Average climate wateroutlet 35°C
General ηs (Seasonal space heating effi ciency)
%155 155 158 162 161 161 161 167 166 158 -
SCOP 4,08 4,08 4,14 4,24 4,23 4,23 4,22 4,37 4,35 4,16 -
Sound power dB(A) 80 83 85 87 88 88 88 90 92 93 93
Sound pressure (at 1m) dB(A) 64 67 69 70 72 72 72 74 76 76 77
Price CZK 542.455,- 578.684,- 617.818,- 659.364,- 697.676,- 765.504,- 777.425,- 844.650,- 903.104,- 1.092.555,- 1.245.475,-Commissioning by DAIKIN service personnel (net price)
CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Water/Water Chiller EWW(H)Q-G(L)-SS
Optional accessories for chiller:
Code Type of unit EWHQ100G-SS EWHQ120G-SS EWHQ130G-SS EWHQ150G-SS EWHQ160G-SS EWHQ190G-SS EWHQ210G-SS EWHQ240G-SS EWHQ270G-SS EWHQ340G-SS EWHQ400G-SS
Mechanical
133 Stacked installation CZK 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,-
08 Brine version CZK 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,-
03 Partial heat recovery CZK 30.502,- 30.502,- 30.502,- 30.968,- 31.159,- 36.421,- 37.490,- 39.902,- 47.191,- 49.932,- 53.166,-
130 Evaporator and condenser victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
29 20Mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
33 20Mm condenser insulation CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
129 Liquid line dìshut of valve CZK 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 8.249,- 8.249,- 8.249,- 8.249,- 9.400,- 9.400,-
126 Discharge and suction line shut-off valve CZK 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,-
127 High and low pressure side manometers CZK 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,-
76-cSound proof system (compressors jacket)
CZK 24.747,- 22.390,- 20.170,- 20.170,- 20.170,- 20.170,- 20.170,- Not available Not available Not available Not available
76-b Sound proof system (compressor) CZK 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,-
91Double pressure relief valve with diverter
CZK 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,-
115 Water fi lter CZK 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 21.239,-
122 Evaporator single pump (low lift) CZK 31.516,- 31.516,- 33.571,- 33.571,- 33.571,- 55.632,- 55.632,- 55.632,- 55.632,- 55.632,- 51.631,-
123 Evaporator single pump (high lift) CZK 36.229,- 36.229,- 38.559,- 38.559,- 38.559,- 64.018,- 64.018,- 64.018,- 64.018,- 64.018,- 59.387,-
124 Condenser single pump (low lift) CZK 31.516,- 31.516,- 33.571,- 33.571,- 33.571,- 55.632,- 55.632,- 55.632,- 55.632,- 55.632,- 51.631,-
125 Condenser single pump (high lift) CZK 36.229,- 36.229,- 38.559,- 38.559,- 38.559,- 64.018,- 64.018,- 64.018,- 64.018,- 64.018,- 59.387,-
Electrical / Control
04 Dol starter CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Not available Not available
132 Part winidng start CZK Not available Not available Not available Not available Not available Not available Not available Not available Not available Not available Not available
06 Soft starter CZK 73.336,- 66.813,- 60.318,- 64.648,- 68.951,- 74.021,- 79.118,- 84.106,- 86.216,- Not available Not available
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,-
17Capacitors for power factor correction
CZK 19.677,- 19.677,- 19.677,- 19.677,- 19.677,- 19.677,- 34.777,- 34.777,- 34.777,- 48.589,- 48.589,-
58 Evaporator fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
59 Condenser fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 8.249,- 8.578,- 8.934,- 8.934,- 8.934,- 10.085,- 11.291,- 11.729,- 12.168,- 41.436,- 70.677,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
102 Ground fault relay CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Operating limits cooling:Condenser outlet temperature: +25°C to + 55°C
Evaporator outlet temperature: -10°C to + 15°C
Operating limits heating:Condenser outlet temperature: +20°C to + 50°C
Evaporator outlet temperature: -8°C to + 15°C
Applied Systems Price list -
EWWQ-L-SS
Standard effi ciency rating, two refrigerant circuits
Type of unit (rated power in
accordance with EN14511)EWWQ180L-SS EWWQ205L-SS EWWQ230L-SS EWWQ260L-SS EWWQ290L-SS EWWQ330L-SS
Cooling capacity kW 187 215 244 273 303 345
Power input kW 41,7 47,3 53,1 60,2 67,1 77,1
Refrigerant circuit 2 2 2 2 2 2
Compressors 4 4 4 4 4 4
EER 4,49 4,55 4,6 4,53 4,52 4,47
ESEER 5,54 5,54 5,52 5,53 5,54 5,53
Length mm 2.801 2.801 2.801 2.801 2.801 2.801
Width mm 928 928 928 928 928 928
Height mm 1.970 1.970 1.970 1.970 1.970 1.970
Weight of unit kg 877 1.062 1.285 1.347 1.439 1.498
Operating weight kg 957 1.156 1.401 1.469 1.575 1.641Space
heating
Average
climate
water
outlet 35°C
General ηs (Seasonal
space heating
effi ciency)
%
155 155 158 162 161 -
SCOP 4,08 4,08 4,14 4,24 4,23 -
Sound power dB(A) 83 86 88 90 91 91
Sound pressure (at 1m) dB(A) 65 68 70 72 74 74
Price CZK 908.613,- 916.067,- 982.524,- 1.046.515,- 1.118.234,- 1.209.574,-
Commissioning chillerCommissioning by DAIKIN
service personnel (net price)CZK 12.079,- 12.079,- 12.079,- 12.079,- 12.079,- 12.079,-
Water/Water Chiller EWW(H)Q-G(L)-SS
Operating limits cooling:Condenser outlet temperature: +25°C to + 55°C
Evaporator outlet temperature: -10°C to + 15°C
Operating limits heating:Condenser outlet temperature: +20°C to + 50°C
Evaporator outlet temperature: -8°C to + 15°C
Optional accessories for chiller:
Code Type of unit EWWQ180L-SS EWWQ205L-SS EWWQ230L-SS EWWQ260L-SS EWWQ290L-SS EWWQ330L-SS
Mechanical
07aHeat pump version with reversibility on water side (including pursuit mode)
CZK 8.249,- 8.249,- 8.249,- 8.249,- 8.249,- 8.249,-
08 Brine version CZK 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,-
03 Partial heat recovery CZK 62.538,- 62.538,- 62.538,- 62.538,- 63.443,- 75.035,-
130 Evaporator and condenser victaulic kit CZK Standard Standard Standard Standard Standard Standard
29 20Mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard
33 20Mm condenser insulation CZK 9.400,- 9.400,- 9.400,- 9.400,- 9.400,- 9.400,-
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard
126 Discharge and suction line shut-off valve CZK 43.190,- 43.190,- 43.190,- 43.190,- 43.190,- 43.190,-
127 High and low pressure side manometers CZK 14.086,- 14.086,- 14.086,- 14.086,- 14.086,- 14.086,-
76-c Sound proof system (compressors jacket) CZK 57.715,- 52.344,- 46.945,- 46.945,- 46.945,- 46.945,-
76-b Sound proof system (compressor) CZK 162.649,- 162.649,- 162.649,- 162.649,- 162.649,- 162.649,-
91Double pressure relief valve with diverter
CZK 38.641,- 38.641,- 38.641,- 38.641,- 38.641,- 38.641,-
115 Water fi lter CZK 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 21.239,-
122 Evaporator single pump (low lift) CZK Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory
123 Evaporator single pump (high lift) CZK Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory
Electrical / Control
04 Dol starter CZK Standard Standard Standard Standard Standard Standard
132 Part winidng start CZK Not available Not available Not available Not available Not available Not available
06 Soft starter CZK 158.209,- 144.945,- 131.818,- 140.834,- 149.905,- 160.319,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including (under / over voltage control,setpoint reset, demand limit, alarm from external device, expansion card pol965)
CZK 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,-
17Capacitors for power factor correction
CZK 36.092,- 36.092,- 36.092,- 36.092,- 36.092,- 36.092,-
58 Evaporator fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
59 Condenser fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 16.306,- 16.991,- 17.704,- 17.704,- 17.704,- 20.033,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard
102 Ground fault relay CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 7.290,- 7.290,- 7.290,- 7.290,- 7.290,- 7.290,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
EWLP-KBW1N
Condenserless chiller
Unit size EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N
Price CZK 101.179,- 128.721,- 148.124,- 165.882,-
Cooling capacity kW 12,1 20 26,8 31,2
EER 2,88 3,03 3,15 3,09
Sound power level dB(A) 64 64 64 71
Options
OPZH glycol application to -5°C LWE CZK 5.974,- 5.974,- 5.974,- 5.974,-
OPZL glycol application to -10°C LWE CZK 5.974,- 5.974,- 5.974,- 5.974,-
Kit
EKLS1 low noise kit 5 HP CZK 8.304,- – – –
EKLS2 low noise kit 8/10/12 HP CZK – 8.304,- 8.304,- 8.304,-
EKAC10C BMS address card CZK 4.714,- 4.714,- 4.714,- 4.714,-
EKRUMCA remote user interface CZK 8.742,- 8.742,- 8.742,- 8.742,-
EHMC10A10 hydraulic module CZK 89.066,- 89.066,- 89.066,- –
EHMC10A80 hydraulic module – pump size up CZK 94.712,- 94.712,- 94.712,- –
EHMC15A10 hydraulic module CZK – – 94.712,- 94.712,-
EHMC15A80 hydraulic module – pump size up CZK – – 98.822,- 98.822,-
EKSSsoft starter (requested Q’ty as per
number of compressor(s) of the unit)CZK on request on request on request on request
Unit size EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N
Price CZK 207.072,- 245.576,- 272.269,-
Cooling capacity kW 40 53,7 62,4
EER 2,99 3,02 3,07
Sound power level dB(A) 67 67 74
Options
OPZH glycol application to -5°C LWE CZK 5.974,- 5.974,- 5.974,-
OPZL glycol application to -10°C LWE CZK 5.974,- 5.974,- 5.974,-
Kit
EKLS2 low noise kit 8/10/12 HP (2 pcs.) CZK 8.304,- 8.304,- 8.304,-
EKAC10C BMS address card CZK 4.714,- 4.714,- 4.714,-
EKRUMCA remote user interface CZK 8.742,- 8.742,- 8.742,-
EHMC15A10 hydraulic module CZK 94.712,- – –
EHMC15A80 hydraulic module – pump size up CZK 98.822,- – –
EHMC30A10 hydraulic module CZK 106.359,- 106.359,- 106.359,-
EHMC30A80 hydraulic module – pump size up CZK 106.359,- 106.359,- 106.359,-
EKSSsoft starter (requested Q’ty as per
number of compressor(s) of the unit)CZK on request on request on request
Note: EKACC is needed for direct BMS connection via Modbus
EKACC is needed to install EKRUMCA
EWLP-KBW1N
Applied Systems Price list -
EWLQ-G-SS
One refrigerant circuit, standard effi ciency rating
Type of unit
(rated power in accordance
with EN14511)
EWLQ090G-SS EWLQ100G-SS EWLQ120G-SS EWLQ130G-SS EWLQ150G-SS EWLQ170G-SS EWLQ190G-SS EWLQ210G-SS EWLQ240G-SS EWLQ300G-SS EWLQ360G-SS
Cooling capacity kW 86,5 98,4 110 125 139 160 181 206 231 290 346
Power input kW 22,4 25,8 29,2 33 36,8 42 47 54,2 59,9 75,6 91,8
Refrigerant circuit 1 1 1 1 1 1 1 1 1 1 1
Compressors 2 2 2 2 2 2 2 2 2 2 2
EER 3,86 3,81 3,78 3,79 3,79 3,8 3,86 3,8 3,85 3,84 3,77
Length mm 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743 2.743
Width mm 928 928 928 928 928 928 928 928 928 928 928
Height mm 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.066 1.186 1.186
Weight of unit kg 494 578 686 714 742 773 807 838 852 967 1.046
Operating weight kg 525 615 729 760 791 826 863 901 916 1.044 1.134
Sound power dB(A) 80 83 85 87 88 88 88 90 92 93 93
Sound pressure (at 1m) dB(A) 64 67 69 70 72 72 72 74 76 76 77
Price CZK 444.071,- 473.695,- 505.732,- 539.796,- 571.120,- 626.643,- 676.109,- 691.401,- 739.277,- 894.335,- 1.019.548,-
Commissioning by
DAIKIN service (net price)CZK 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,- 8.323,-
Optional accessories for chiller:
Code Type of unit EWLQ090G-SS EWLQ100G-SS EWLQ120G-SS EWLQ130G-SS EWLQ150G-SS EWLQ170G-SS EWLQ190G-SS EWLQ210G-SS EWLQ240G-SS EWLQ300G-SS EWLQ360G-SS
Mechanical
133 Stacked installation CZK 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,- 44.588,-
08 Brine version CZK 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,- 12.935,-
03 Partial heat recovery CZK Not available Not available Not available Not available Not available Not available Not available Not available Not available Not available Not available
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
29 20mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
126Discharge and suction line shut-off
valveCZK 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,- 21.568,-
127High and low pressure side
manometersCZK 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,- 7.043,-
76-cSound proof system (compressors
jacket)CZK 24.747,- 22.390,- 20.170,- 20.170,- 20.170,- 20.170,- 20.170,- Not available Not available Not available Not available
76-b Sound proof system (compressor) CZK 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,- 81.338,-
91Double pressure relief valve with
diverterCZK 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,-
115 Water fi lter CZK 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 21.239,-
122 Evaporator single pump (low lift) CZK 31.516,- 31.516,- 33.571,- 33.571,- 33.571,- 55.632,- 55.632,- 55.632,- 55.632,- 55.632,- 51.631,-
123 Evaporator single pump (high lift) CZK 36.229,- 36.229,- 38.559,- 38.559,- 38.559,- 64.018,- 64.018,- 64.018,- 64.018,- 64.018,- 59.387,-
Electrical / Control
04 Dol starter CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Not available Not available
132 Part winidng start CZK Not available Not available Not available Not available Not available Not available Not available Not available Not available Standard Standard
06 Soft starter CZK 73.336,- 66.813,- 60.318,- 64.648,- 68.951,- 74.021,- 79.118,- 84.106,- 89.121,- Not available Not available
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
15a
Control expansion pack
including (under / over voltage
control,setpoint reset, demand
limit, alarm from external device,
expansion card pol965)
CZK 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,-
17Capacitors for power factor
correctionCZK 19.677,- 19.677,- 19.677,- 19.677,- 19.677,- 19.677,- 34.777,- 34.777,- 34.777,- 48.589,- 48.589,-
58 Evaporator fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 8.249,- 8.578,- 8.934,- 8.934,- 8.934,- 10.085,- 11.291,- 11.729,- 12.168,- 41.436,- 70.677,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
102 Ground fault relay CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,- 5.152,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Condenserless model
EWLQ-L-SS
Standard effi ciency rating, two refrigerant circuits
Type of unit
(rated power in accordance
with EN14511)
EWLQ180L-SS EWLQ205L-SS EWLQ230L-SS EWLQ260L-SS EWLQ290L-SS EWLQ330L-SS
Cooling capacity kW 173 197 224 249 279 317
Power input kW 44,3 51,1 57,9 65,6 73,2 83,8
Refrigerant circuit 2 2 2 2 2 2
Compressors 4 4 4 4 4 4
EER 3,91 3,86 3,87 3,79 3,81 3,78
Length mm 2.801 2.801 2.801 2.801 2.801 2.801
Width mm 928 928 928 928 928 928
Height mm 1.970 1.970 1.970 1.970 1.970 1.970
Weight of unit kg 832 1.007 1.202 1.252 1.333 1.380
Operating weight kg 894 1.081 1.292 1.345 1.436 1.486
Sound power dB(A) 83 86 88 90 91 91
Sound pressure (at 1m) dB(A) 65 68 70 72 74 74
Price CZK 821.821,- 828.590,- 888.717,- 946.569,- 1.011.409,- 1.094.062,-
Commissioning chiller
Commissioning by DAIKIN service
personnel (net price)CZK 12.079,- 12.079,- 12.079,- 12.079,- 12.079,- 12.079,-
Condenserless model
Optional accessories for chiller:
Code Type of unit EWLQ180L-SS EWLQ205L-SS EWLQ230L-SS EWLQ260L-SS EWLQ290L-SS EWLQ330L-SS
Mechanical
08 Brine version CZK 25.816,- 25.816,- 25.816,- 25.816,- 25.816,- 25.816,-
20 Evaporator victaulic kit CZK Standard Standard Standard Standard Standard Standard
29 20mm evaporator insulation CZK Standard Standard Standard Standard Standard Standard
60 Electronic expansion valve CZK Standard Standard Standard Standard Standard Standard
126Discharge and suction line shut-off
valveCZK 43.190,- 43.190,- 43.190,- 43.190,- 43.190,- 43.190,-
127High and low pressure side
manometersCZK 14.086,- 14.086,- 14.086,- 14.086,- 14.086,- 14.086,-
76-c Sound proof system (compressors jacket) CZK 57.715,- 52.344,- 46.945,- 46.945,- 46.945,- 46.945,-
76-b Sound proof system (compressor) CZK 162.649,- 162.649,- 162.649,- 162.649,- 162.649,- 162.649,-
91Double pressure relief valve with
diverterCZK 38.641,- 38.641,- 38.641,- 38.641,- 38.641,- 38.641,-
115 Water fi lter CZK 13.511,- 13.511,- 13.511,- 13.511,- 13.511,- 21.239,-
122 Evaporator single pump (low lift) CZK Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory
123 Evaporator single pump (high lift) CZK Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory Contact Factory
Electrical / Control
04 Dol starter CZK Standard Standard Standard Standard Standard Standard
132 Part winidng start CZK Not available Not available Not available Not available Not available Not available
06 Soft starter CZK 158.209,- 144.945,- 131.818,- 140.834,- 149.905,- 160.319,-
10 Double setpoint CZK Standard Standard Standard Standard Standard Standard
15a
Control expansion pack including
(under / over voltage control,setpoint
reset, demand limit, alarm from
external device, expansion card
POL965)
CZK 10.606,- 10.606,- 10.606,- 10.606,- 10.606,- 10.606,-
17 Capacitors for power factor correction CZK 36.092,- 36.092,- 36.092,- 36.092,- 36.092,- 36.092,-
58 Evaporator fl ow switch CZK 6.084,- 6.084,- 6.084,- 6.084,- 6.084,- 6.084,-
68 Hour run meter CZK Standard Standard Standard Standard Standard Standard
69 General fault contactor CZK Standard Standard Standard Standard Standard Standard
95 Compressors circuit breakers CZK 16.306,- 16.991,- 17.704,- 17.704,- 17.704,- 20.033,-
97 Main switch interlock door CZK Standard Standard Standard Standard Standard Standard
102 Ground fault relay CZK 20.417,- 20.417,- 20.417,- 20.417,- 20.417,- 20.417,-
128 Master/Slave CZK Standard Standard Standard Standard Standard Standard
Installation
75 Rubber anti vibration mounts CZK 7.290,- 7.290,- 7.290,- 7.290,- 7.290,- 7.290,-
Communication cards / Accessories
EKCM200J BMS card (ModBUS-RTU) CZK 9.756,- 9.756,- 9.756,- 9.756,- 9.756,- 9.756,-
EKCMBACMSTP BMS card (BacNet/ MSTP) CZK 11.647,- 11.647,- 11.647,- 11.647,- 11.647,- 11.647,-
EKCMLON BMS card (LonWorks) CZK 11.346,- 11.346,- 11.346,- 11.346,- 11.346,- 11.346,-
Applied Systems Price list -
ERQ Inverter heat pump
condensing units
ERQ-A
High effi ciency inverter heat pump outdoor units for connection
to DX heat exchangers in Air Handling Units (AHU) or to CYQ Air
Curtains
Outdoor units
HYDRONIC KIT
UATYQ-CY1
Rooftop heat pump
Convertible return and supply air: fan can be mounted in two
directions
UATYP-AY1
Rooftop heat pump
Belt driven fan enables air volume and static pressure to be
adjusted as required.
Buff er tanks
EKBT 200 l buff er tank with casing CZK 58.537,-
EKBT500N 500 l buff er tank CZK 56.694,-
EKBTC10N 1000 l buff er tank CZK 78.604,-
EKBT500C 500 l buff er tank with casing CZK 163.060,-
EKBTC10C 1000 l buff er tank with casing CZK 164.236,-
Hydraulic modules
EHMC10A10 hydraulic module CZK 89.066,-
EHMC10A80 hydraulic module – high ESP CZK 94.712,-
EHMC15A10 hydraulic module CZK 94.712,-
EHMC15A80 hydraulic module – high ESP CZK 98.822,-
EHMC30A10 hydraulic module CZK 106.359,-
EHMC30A80 hydraulic module – high ESP CZK 106.359,-
HYDRONIC KIT, ROOFTOP
Unit size UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 UATYQ900CY1
Price CZK 180.414,- 261.846,- 338.580,- 402.867,- 417.798,- 419.337,- 461.271,-
Cooling capacity kW 27,34 35,58 44,72 55,69 66,82 72,6 93,1
EER 3,36 3,30 3,43 3,33 3,4 3,36 3,27
Heating capacity kW 24,91 34,79 41,79 53,93 61,69 69,61 87,9
COP 3,40 3,21 3,25 3,47 3,32 3,25 3,15
Sound power level dB(A) 82 83 83 87 90 90 90
Options
DEC101A51 CZK 207.306,- 288.738,- 365.472,- 429.759,- 444.690,- 446.229,- 473.121,-
DEC102A51 CZK 210.060,- 291.492,- 368.226,- 432.513,- 447.444,- 448.983,- 490.917,-
DTA103A51 CZK 197.343,- 278.775,- 355.509,- 419.796,- 434.727,- 436.266,- 478.200,-
ECONO250AY1 CZK 222.102,- – – – – – –
ECONO350AY1 CZK – 305.667,- – – – – –
ECONO450AY1 CZK – – 384.588,- – – – –
ECONO550AY1 CZK – – – 451.143,- – – –
ECONO600AY1 CZK – – – – 468.477,- – –
ECONO700AY1 CZK – – – – – 472.581,- –
ECONO900AY1 CZK – – – – – – 518.775,-
Unit size UATYPC10AY1 UATYPC12AY1
Price CZK 614.655,- 704.673,-
Cooling capacity kW 101,10 109,60
EER 2,34 2,27
Heating capacity kW 102,30 126,30
COP 2,45 2,7
Sound pressure level at 1m dB(A) 80 80
Type for 1~ 230V power supply ERQ100AV1 ERQ125AV1 ERQ140AV1
Capacity index 100 125 140
Nominal cooling capacity kW 11,2 14,0 15,5
Nominal heating capacity kW 12,5 16,0 18,0
Price CZK 86.103,- 107.595,- 120.528,-
Type for 3N~ 400V power supply ERQ125AW1 ERQ200AW1 ERQ250AW1
Capacity index 125 200 250
Nominal cooling capacity kW 14,0 22,4 28,0
Nominal heating capacity kW 16,0 25,0 31,5
Price CZK 93.744,- 149.499,- 174.339,-
Notes:
- When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain
- Specifi ed capacity values are for evaporation temperature = °C (cooling) / condensing temperature = °C (heating), evaporator superheat = K,condenser sub-cool = K,
on-coil temperature = °CDB / °CWB (cooling) / = °CDB (heating)
Expansion valve kitAllowed heat exchanger capacity [kW] Combinable units
Price CZKMinimum Maximum ERQ100- ERQ125- ERQ140- ERQ200- ERQ250-
EKEXV63 6,3 7,8 • • 4.590,-
EKEXV80 7,9 9,9 • • • 4.887,-
EKEXV100 10,0 12,3 • • • • 5.076,-
EKEXV125 12,4 15,4 • • • • • 5.346,-
EKEXV140 15,5 17,6 • • • • 5.535,-
EKEXV200 17,7 24,6 • • 6.021,-
EKEXV250 24,7 30,8 • • 6.399,-
Notes:
- An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains,
- The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger,
- The AHU heat exchanger needs to be designed for bar pressures, with an internal (refrigerant) volume between , and , l (not counting headers and distributors)
- Specifi ed capacity values are for evaporation temperature = °C (cooling) / condensing temperature = °C (heating), evaporator superheat = K,condenser sub-cool = K,
on-coil temperature = °CDB / °CWB (cooling) / = °CDB (heating)
Unit-specifi c Accessories
EKEQDCB EKEQFCBA Price CZK
BRC1D52 Basic wired remote controller with weekly timer • • 3.105,-
BRC1E53AStandard wired remote controller with full-text interface and back-light with new energy
saving, sound minimization & duty rotation functions for Austria • 4.077,-
BRC1E53B
Standard wired remote controller with full-text interface and back-light with new energy
saving, sound minimization & duty rotation functions for Czech, Croatia, Hungarian,
Romanian, Slovenian, Bulgarian• 4.077,-
BRC1E53CStandard wired remote controller with full-text interface and back-light with new energy
saving, sound minimization & duty rotation functions for Slovakian and Albanian • 4.077,-
KRP4A51 Adaptor for external monitoring/control • 4.968,-
RTD-20 Adaptor for external monitoring/control with 0-10VDC linear capacity control • 11.745,-
KRCS01-1 External room temperature sensor • 2.376,-
KRC19-26 Mechanical cool/heat selector • • 1.620,-
KJB111A Fixing box for cool/heat selector • • 756,-
* BRC1E53 will be available in May 2016, in case of unavailability please use BRC1E52B
Notes:
- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)
- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC- Cool/Heat selector
Control box EKEQDCB EKEQFCBA
Control type Daikin control Free (External) control
Control options
Room temperature control [via Remote Controller
(accessory) or via External room temperature sensor
(accessory)]
Return air temperature control (via a supplied thermistor)
• (X-Control): 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted)
• (Y-Control): Fixed evaporation / condensation temperature control
• (W-Control): 0~10V linear capacity control (0V = 0% capacity, 10V = 100% capacity
• Connection ratio 50 ~ 110% (ERQ)
Price CZK 19.575,- 21.816,-
Notes:
- A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains
- A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCBA box, it is optional (required for commissioning and servicing only)
- Switching between cooling/heating operation with the EKEQFCBA box must be done from the external control system, or via the optional KRC- Cool/Heat selector
Applied Systems Price list -
Low ESP duct unit FWE-C 02 03 04 06 07 08 10
FWE**CT-, 2 pipe unit,
standard, without valvesCZK 7.125,- 8.057,- 8.770,- 11.428,- 12.360,- 14.415,- 17.347,-
FWE**CTV, 2 pipe unit,
with 3-ways 230V on/off valve, factory mounted CZK 12.360,- 13.264,- 13.977,- 16.635,- 17.567,- 19.622,- 22.554,-
FWE**CTT, 2 pipe unit,
with 2-ways 230V on/off valve, factory mountedCZK 10.058,- 11.072,- 11.702,- 14.415,- 15.265,- 17.347,- 20.280,-
Cooling capacity (Total at Super High Speed) kW 2,17 3,22 4,34 6,06 6,83 7,84 9,96
Heating capacity (2-pipe at Super High Speed) kW 2,79 4,28 5,61 7,66 9,26 10,50 13,00
FWE**CF-, 4 pipe unit,
standard, without valvesCZK 8.359,- 9.427,- 10.195,- 13.127,- 14.059,- 16.498,- 19.403,-
FWE**CFV, 4 pipe unit,
with 3-ways 230V on/off valves, factory mounted CZK 17.402,- 18.553,- 19.348,- 22.280,- 23.130,- 25.541,- 28.474,-
FWE**CFT, 4 pipe unit,
with 2-ways 230V on/off valves, factory mountedCZK 14.141,- 15.210,- 15.977,- 18.909,- 19.841,- 22.280,- 25.185,-
Cooling capacity (Total at Super High Speed) kW 2,10 3,16 3,98 6,05 6,76 7,79 9,91
Heating capacity (4-pipe at Super High Speed) (1) kW 2,30 3,53 4,56 6,17 7,60 8,52 10,40
Accessories for FWE-C 02 03 04 06 07 08 10
2 pipes 3-ways on/off 230V valve kit EK2MV3B10C5
CZK 2.960,-
2 pipes 2-ways on/off 230V valve kit EK2MV2B10C5
CZK 2.220,-
4 pipes 3-ways on/off 230V valve kit EK4MV3B10C5
CZK 5.097,-
4 pipes 2-ways on/off 230V valve kit EK4MV2B10C5
CZK 4.330,-
Controller for FWE-C 02 03 04 06 07 08 10
Controller electronic
Standard version, (see note 2)
FWEC1A
CZK 3.042,-
Controller electronic
Advanced version
FWEC2A
CZK 4.412,-
Controller electronic
Advanced Plus version
FWEC3A
CZK 6.002,-
FWECSA Split type electronic controller FWECSA
FWECSAP power control boardFWECSAP
CZK 4.577,-
FWECSAC control panel for remote or on board
installation
FWECSAC
CZK 3.426,-
Wall mounting kit (spacing collar)
for FWEC1A /2A and 3A
FWFCKA
CZK 384,-
Temperature sensor kit
for FWEC1A /2A and 3A
FWTSKA
CZK 384,-
Relative humidity sensor kit
for FWEC2A and FWEC3A
FWHSKA
CZK 685,-
Master / Slave interfaceEPIMSB6
CZK 4.494,-
Notes:
() Rating conditions: air °C DB, entering water °C, leaving water °C
() FWECA can operate with speeds of fan only, if it also manages valves on -pipes unit
FWE-C
Fan coil, ACCESSORIES
-speed fan motor, available static pressure up to Pa
FWE-C, Low ESP duct fan coil
Medium ESP duct unit FWB-B 02 03 04 05 06 07 08 09 10
FWB**BTN, 2 pipe unit,
standard, without valvesCZK 13.785,- 14.634,- 15.484,- 18.772,- 19.403,- 21.184,- 25.624,- 27.049,- 28.830,-
FWB**BTV, 2 pipe unit,
with 3-ways 230V on/off valve, factory mountedCZK 18.115,- 19.046,- 19.923,- 23.130,- 23.842,- 25.624,- 30.255,- 31.680,- 33.462,-
FWB**BTNE, 2 pipe unit, without valves and
electric heater, factory mountedCZK 22.116,- 23.048,- 23.979,- 28.035,- 28.748,- 30.557,- 35.599,- 37.052,- 38.833,-
FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off
valve and electric heater, factory mounted CZK 26.555,- 27.405,- 28.337,- 32.475,- 33.105,- 34.969,- 40.258,- 41.683,- 43.464,-
Cooling capacity (Total at High Speed) kW 2,61 3,14 3,49 5,08 5,45 6,47 7,57 8,67 10,34
Heating capacity (2-pipe at High Speed) kW 5,47 6,01 6,47 10,31 11,39 12,28 15,05 16,85 18,78
Heating capacity (4-pipe at High Speed) kW 3,14 3,14 3,14 5,99 5,99 5,99 12,80 12,80 12,80
Accessories for FWB-B 02 03 04 05 06 07 08 09 10
Additional single row
heat exchanger
EAH04A6 EAH07A6 EAH10A6
CZK 4.714,- 5.481,- 7.454,-
3-way valve add. h/eE2MV307A6 E2MV310A6
CZK 4.878,- 4.878,-
2-way valve add. h/eE2MV207A6 E2MV210A6
CZK 2.741,- 2.741,-
Fan stop thermostatYFSTA6
CZK 521,-
Controller for FWB-B 02 03 04 05 06 07 08 09 10
Controller electronic
Standard version
FWEC1A
CZK 3.042,-
Controller electronic
Advanced version
FWEC2A
CZK 4.412,-
Controller electronic
Advanced Plus version
FWEC3A
CZK 6.002,-
FWECSA Split type electronic controller FWECSA
FWECSAP power control boardFWECSAP
CZK 4.577,-
FWECSAC control panel for remote or on board
installation
FWECSAC
CZK 3.426,-
Wall mounting kit (spacing collar)
for FWEC 1A /2A and 3A
FWFCKA
CZK 384,-
Temperature sensor kit
for FWEC*A
FWTSKA
CZK 384,-
Relative humidity sensor kit
for FWEC2A and FWEC3A
FWHSKA
CZK 685,-
Master / Slave interfaceEPIMSB6
CZK 4.494,-
FWB-B
Fan coil, Accessories
Low sound power levels and electrical absorption thanks to plastic
impeller and improved electric motor.
FWB-B, Medium ESP duct fan coil
Applied Systems Price list -
Medium ESP duct unit with DC fan motor FWP-A 02 03 04 05 06 07
FWP**ATN, 2 pipe unit,
standard, without valvesCZK 19.622,- 20.472,- 21.266,- 24.911,- 25.185,- 26.912,-
FWP**ATV, 2 pipe unit,
with 3-ways 230V on/off valve, factory mountedCZK 23.979,- 24.829,- 25.624,- 29.323,- 29.625,- 31.324,-
FWP**ATNE, 2 pipe unit, without valves and
electric heater, factory mountedCZK 28.035,- 28.912,- 29.680,- 34.256,- 34.530,- 36.257,-
FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off
valve and electric heater, factory mounted CZK 32.393,- 33.270,- 34.037,- 38.668,- 38.970,- 40.669,-
Cooling capacity (Total at High Speed) kW 2,61 3,14 3,49 5,08 5,45 6,47
Heating capacity (2-pipe at High Speed) kW 5,47 6,01 6,47 10,31 11,39 12,28
Heating capacity (4-pipe at High Speed) kW 3,14 3,14 3,14 5,99 5,99 5,99
Accessories for FWP-A 02 03 04 05 06 07
Additional single row
heat exchanger
EAH04A6 EAH07A6
CZK 4.714,- 5.481,-
3-way valve add. h/eE2MV307A6
CZK 4.878,-
2-way valve add. h/eE2MV207A6
CZK 2.741,-
Controller for FWP-A 02 03 04 05 06 07
Controller electronic
Advanced Plus version
FWEC3A
CZK 6.002,-
FWECSA Split type electronic controller FWECSA
FWECSAP power control board FWECSAP
CZK 4.577,-
FWECSAC control panel for remote or on board
installation
FWECSAC
CZK 3.426,-
Wall mounting kit (spacing collar)
for FWEC 1A /2A and 3A
FWFCKA
CZK 384,-
Temperature sensor kit
for FWEC*A
FWTSKA
CZK 384,-
Relative humidity sensor kit
for FWEC2A and FWEC3A
FWHSKA
CZK 685,-
FWP-A
Fan coil, Accessories
Low sound level and up to % energy saving thanks to the BLDC
motor technology
FWP - A, Medium ESP duct fan coil with DC fan motor
2-pipe unit FWN**AT 04 05 06 07 08 10
Price CZK 20.736,- 22.248,- 37.152,- 39.339,- 40.635,- 42.525,-
Cooling capacity (Total at High Speed) kW 3,91 4,76 6,17 6,81 7,83 8,75
Heating capacity (2-pipe at High Speed) kW 4,85 5,79 7,67 8,65 9,46 10,70
4-pipe unit FWN**AF 04 05 06 07 08 10
Price CZK 23.382,- 25.515,- 40.311,- 42.309,- 44.415,- 46.899,-
Cooling capacity (Total at High Speed) kW 3,88 4,72 6,06 6,69 7,70 8,60
Heating capacity (4-pipe at High Speed) kW 4,48 4,45 6,53 6,44 9,13 9,07
Accessories for FWN 04 05 06 07 08 10
Electric heater
low capacity
EDEH04B6 EDEHS06B6 EDEHS10B6
CZK 8.451,- 14.553,- 14.553,-
Electric heater
high capacity
EDEH04B6 EDEHB06B6 EDEHB10B6
CZK 8.451,- 14.553,- 14.553,-
2-pipe 3-way valveED2MV04A6 ED2MV10A6
CZK 6.769,- 6.769,-
4-pipe 3-way valveED4MV04A6 ED4MV10A6
CZK 13.017,- 13.017,-
Vertical drainpanEDDPV10A6
CZK 521,-
Horizontal drainpanEDDPH10A6
CZK 521,-
Fresh air intakeEDMFA04A6 EDMFA06A6 EDMFA10A6
CZK 30.611,- 30.995,- 31.735,-
Controller for FWN 04 05 06 07 08 10
Controller electronic
Advanced Plus version
FWEC3A
CZK 6.002,-
FWECSA Split type electronic controller FWECSA
FWECSAP power control board FWECSAP
CZK 4.577,-
FWECSAC control panel for remote or on board
installation
FWECSAC
CZK 3.426,-
Wall mounting kit (spacing collar)
for FWEC 1A /2A and 3A
FWFCKA
CZK 384,-
Temperature sensor kit
for FWEC*A
FWTSKA
CZK 384,-
Relative humidity sensor kit
for FWEC2A and FWEC3A
FWHSKA
CZK 685,-
FWN-A
Fan coil, Accessories
BLDC fan motor unit for horizontal or vertical mounting.
Continuous air fl ow regulation and fan speed modulation.
Up to % energy savings with brushless DC motor technology
compared to traditional technology
FWN - A, Medium ESP flexi type fan coil
Applied Systems Price list -
FWF-C cassette unit 02 03 04
FWF**CT, 2 pipe unit,
incl. condensate pump, without valvesCZK 14.991,- 16.909,- 17.128,-
Cooling capacity (Total at High Speed) kW 2,49 4,10 4,54
Heating capacity (2-pipe at High Speed) kW 3,52 4,69 5,28
Note: Decoration panel is mandatory, it is included with other accessories in table on page .
FWF-B cassette unit 02 03 04 05
FWF**BT, 2 pipe unit,
incl. condensate pump, without valvesCZK 19.266,- 20.554,- 21.705,- 22.828,-
Cooling capacity (Total at Super High Speed) kW 2,00 3,20 4,20 5,20
Heating capacity (2-pipe at Super High Speed) kW 2,90 4,00 5,40 6,70
FWF**BF, 4 pipe unit,
incl. condensate pump, without valvesCZK 20.992,- 22.417,- 23.404,- 24.418,-
Cooling capacity (Total at Super High Speed) kW 2,00 2,70 3,50 4,50
Heating capacity (4-pipe at Super High Speed) kW 3,80 3,80 4,90 6,10
Note: Decoration panel is mandatory, it is included with other accessories in table on page .
FWC-B cassette unit 06 07 08 09
FWC**BT, 2 pipe unit,
incl. condensate pump, without valvesCZK 27.542,- 29.406,- 31.050,- 32.694,-
Cooling capacity (Total at High Speed) kW 5,80 6,80 7,70 8,70
Heating capacity (2-pipe at High Speed) kW 8,00 8,90 10,60 12,10
FWC**BF, 4 pipe unit,
incl. condensate pump, without valvesCZK 34.475,- 36.832,- 38.531,- 40.176,-
Cooling capacity (Total at High Speed) kW 5,80 6,60 7,60 8,70
Heating capacity (4-pipe at High Speed) kW 7,50 8,40 9,70 11,00
Note: Decoration panel is mandatory, it is included with other accessories in table on page .
FWF-C
Fan coil
Infrared remote control as standard with decoration panel kit.
FWF-B
Fan coil
Possibility to shut or fl aps for easy installations in corners.
FWC-B
Fan coil
° air discharge ensures uniform air fl ow and temperature
distribution.
FWF-C, FWF-B, FWC-B, Cassette fan coils
2-pipe unit FWD**AT 04 06 08 10 12 16 18
Price CZK 16.498,- 21.705,- 25.404,- 28.255,- 35.106,- 45.026,- 49.521,-
Cooling capacity (Total at High Speed) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30
Heating capacity (2-pipe at High Speed) kW 4,05 7,71 9,43 10,79 14,45 19,81 21,92
4-pipe unit FWD**AF 04 06 08 10 12 16 18
Price CZK 19.348,- 25.267,- 29.488,- 32.694,- 41.190,- 52.179,- 57.167,-
Cooling capacity (Total at High Speed) kW 3,90 6,20 7,80 8,82 11,90 16,40 18,30
Heating capacity (4-pipe at High Speed) kW 4,49 6,62 9,21 9,21 15,86 21,15 21,15
Accessories for FWD 04 06 08 10 12 16 18
Electric heater
low capacity
EDEH04B6 EDEHS06B6 EDEHS10B6 EDEHS12B6 EDEHS18B6
CZK 8.451,- 14.553,- 14.553,- 16.059,- 18.115,-
Electric heater
high capacity
EDEH04B6 EDEHB06B6 EDEHB10B6 EDEHB12B6 EDEHB18B6
CZK 8.451,- 14.553,- 14.553,- 16.059,- 18.115,-
2-pipe 3-way valveED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6
CZK 6.769,- 6.769,- 6.769,- 7.016,-
4-pipe 3-way valveED4MV04A6 ED4MV10A6 2 x ED2MV12A6 2 x ED2MV18A6
CZK 13.017,- 13.017,- 13.538,- 14.031,-
Vertical drainpanEDDPV10A6 EDDPV18A6
CZK 521,- 685,-
Horizontal drainpanEDDPH10A6 EDDPH18A6
CZK 521,- 685,-
Fan stop thermostatYFSTA6
CZK 521,-
Fresh air intakeEDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6
CZK 30.611,- 30.995,- 31.735,- 33.352,- 34.174,-
Controller for FWD 04 06 08 10 12 16 18
Controller electronic
Standard version
FWEC1AFWEC1A
EPIB6 requested
CZK 3.042,- 3.042,-
Controller electronic
Advanced version
FWEC2AFWEC2A
EPIB6 requested
CZK 4.412,- 4.412,-
Controller electronic
Advanced Plus version
FWEC3AFWEC3A
EPIB6 requested
CZK 6.002,- 6.002,-
FWECSA Split type electronic controller FWECSAFWECSA
EPIB6 requested
FWECSAP power control board FWECSAP
CZK 4.577,-
FWECSAC control panel for remote or on board
installation
FWECSAC
CZK 3.426,-
Wall mounting kit (spacing collar)
for FWEC 1A /2A and 3A
FWFCKA
CZK 384,-
Temperature sensor kit
for FWEC*A
FWTSKA
CZK 384,-
Relative humidity sensor kit
for FWEC2A and FWEC3A
FWHSKA
CZK 685,-
Master / Slave interface EPIMSB6
CZK 4.494,-
Power interface –EPIB6
CZK 4.494,-
Note:
For FWD size , or EPIB needs to be used for each FWD unit to connect to FWEC*A controllers.
If FWD size , or are used in Master/Slave application by using EPIMSB still EPIB needs to be used for each FWD to connect to EPIMSB.
FWD-A
Fan coil, Accessories
Straight duct connector is mounted to discharge side
FWD - A, High ESP flexi type fan coil
Applied Systems Price list -
Type FWF-CT FWT-CT
Decoration panel 2-pipe
Incl. wireless controller
DCP600TC–
CZK 4.851,-
Standard wired remote control MERCA
CZK 3.892,-
Simplifi ed wired remote control SRC-COA
CZK 2.055,-
Simplifi ed wired remote control SRC-HPA
CZK 2.055,-
Wireless control WRC-HPC
CZK 767,-
2-pipe 3-way valve MCKCW2T3VN–
CZK 4.412,-
Accessories for FWG - A
Decoration Panel / FWG AT 2 pipes
include GS02 wireless controller
DCP900BTA
CZK 5.015,-
Decoration Panel / FWG AF 4 pipes
include GS02 wireless controller
DCP900BFA
CZK 5.015,-
Wired controller BRC51A61
CZK 3.042,-
Wireless controller
Decoration panel already include
Type GS02
CZK Decoration panel already included
Valve kit 3-ways ON/OFF 230 V
2 pipe version
VKFWGA012T3V VKFWGA022T3V
CZK 3.645,- 3.946,-
Valve kit 3-ways ON/OFF 230 V
4 pipe version
VKFWGA014T3V VKFWGA024T3V
CZK 7.454,- 7.756,-
FWT-C wall mounted unit 02 03 04 05 06
FWT**CT, 2 pipe unit,
without valvesCZK 9.701,- 10.058,- 11.565,- 13.922,- 14.908,-
Cooling capacity (Total at High Speed) kW 2,34 2,78 3,22 4,54 5,28
Heating capacity (2-pipe at High Speed) kW 3,02 3,75 4,10 6,01 6,74
FWG - A cassette unit 05 08 11
FWG**AT 2 pipe unit ,
incl, condensate pump, without valvesCZK 29.844,- 32.694,- 34.613,-
Cooling Capacity (Total at High Speed) kW 5,90 8,80 11,75
Heating Capacity (2 pipe at High Speed) kW 7,10 11,20 13,70
FWG**AF 4 pipe unit ,
incl, condensate pump, without valvesCZK 32.612,- 35.599,- 37.463,-
Cooling Capacity (Total at High Speed) kW 4,40 7,20 9,00
Heating Capacity (4 pipe at High Speed) kW 7,65 11,20 15,65
Note: Decoration panel is mandatory, it is include with other accessories in below table
FWT-C
Fan coil
Flexibility via interchangeable water connection side.
FWG-A
Cassette fan coils with DC fan motor
Low sound level and up to % energy saving thanks to the
BLDC motor technology infrared remote control is standard with
decoration panel kit.
FWT-C + FWF-C
Accessories
FWG-A cassette fan coil, FWT-C Wall mounted fan coil, Accessories for FWT-C, FWF-C, FWG-A,
FWC-B, FWF-B
Accessories
Accessories for FWC-B, FWF-B
Options FWC-B FWF-B
Decoration Panel Round Flow StandardBYCQ140C
-CZK 7.344,-
Decoration Panel 4-way blow -BYFQ60B3
CZK 7.654,-
Sealing member of air discharge outletKDBHQ55C140 KDBH44BA60
CZK 3.134,- 4.001,-
Long-life fi lterKAFP551K160 KAFQ441BA60
CZK 2.908,- on request
Panel spacer -KDBQ44B60
CZK 13.745,-
Fresh air intake kitCE.KDDQ55C140 KDDQ44XA60
CZK 15.969,- 4.611,-
Control Systems
Remote control Infrared H/PBRC7F532F (11) BRC7E530 (11)
CZK 5.022,- 5.177,-
Remote control Infrared C/OBRC7F533F (11) BRC7E531 (11)
CZK 3.647,- 8.527,-
Remote Control WiredBRC315D (1)
CZK 3.426,-
Central remote controlDCS302C51 (2)
CZK 48.899,-
Electrical box with earth terminal (3
blocks)
KJB311A
CZK 2.320,-
Unifi ed on/off controlDCS301B51 (5)
CZK 20.587,-
Electrical box with earth terminal (2
blocks)
KJB212A
CZK 2.230,-
Shedule timerDST301B51 (5)(8)
CZK 25.726,-
Wiring adapter for electrical
appendices 1
KRP2A52 (4)(8)
CZK 10.189,-
Wiring adapter for electrical
appendices 2
KRP4A53 (4)(8)
CZK 5.183,-
Installation box for adapter PCBKRP1H98 (9) KRP1BA101 (9)
CZK 1.469,- 1.948,-
Remote SensorKRCS01-4 KRCS01-1
CZK 2.469,- 2.376,-
Intelligent touch controllerDCS601C51 (3)(7)
CZK 54.297,-
Electrical installation boxKJB411A
CZK 4.007,-
Optional PCB for MOD-bus connectionEKFCMBCB (4)(8)
CZK 2.823,-
2-way valve - On/Off EKMV2C09B (4)(6)(10)
CZK 2.357,-
3-way valve - On/Off EKMV3C09B (4)(6)(10)
CZK 2.658,-
Valve control PCBEKRP1C11
CZK 2.263,-
Remote “On/Off ” and “forced off ” kit -EKRORO (12)
CZK 754,-
Notes:
. Optional, electrical installation box with earth terminal KJBA is required, if
controller wires need to be installed in the wall.
. Requires electrical installation box with earth terminal KJBA.
. Requires electrical installation box KJBA.
. Requires installation box KRPH for FWC-B and KRPBA for FWF-B.
. Requires electrical installation box with earth terminal KJBA, if built in the wall.
. Requires valve control PCB EKRPC.
. I-touch:
• Not allowed to use the i-touch for an installation with both fan coils and VRV
units.
• Can not be used in combination with fan coil units, that use MOD bus
communication.
• No Airnet or telephone connection possible.
. Only of these options can be installed on indoor unit.
. FWC -B: Max. KRPH box can be mounted on the unit.
Max. PCB’s can be mounted in KRPH box.
FWF-B: Max. KRPBA boxes can be mounted on the unit.
Max. PCB can be mounted in KRPBA box.
. FWC-B - -pipe unit: x valve kit + x installation box for PCB KRPH + x valve
control PCB EKRPC
FWC-B - -pipe unit: x valve kit + x installation box for PCB KRPH + x valve
control PCB EKRPC
FWF-B - -pipe unit: x valve kit + x installation box for PCB KRPBA + x valve
control PCB EKRPC.
FWF-B - -pipe unit: x valve kit + x installation box for PCB KRPBA + x valve
control PCB EKRPC.
. It is possible to change the operation mode, but this will not have an impact on
the water temperature.
(No feed back to water source)
It is not possible to select the “auto air fl ow” setting.
Dry operation can be selected with this remote control, but this function is not
available on the FWC-B / FWF-B model.
. This option is needed to create T T wire.
All options are supplied as kit.
Applied Systems Price list -
FWV - D, Floor standing fan coil
FWV-D
Fan coil
Low Wall unit FWV 01 15 02 25 03 35 04 06 08 10
FWV**DTN, 2 pipe unit,
standard, without valveCZK 9.208,- 9.564,- 10.140,- 10.852,- 11.126,- 12.195,- 12.771,- 13.840,- 18.334,- 20.828,-
FWV**DTV, 2 pipe unit,
with 3-way on/off 230V valve, factory mountedCZK 15.566,- 15.977,- 16.498,- 17.210,- 17.567,- 18.635,- 19.348,- 20.417,- 25.487,- 27.981,-
FWV**DATD6V3, 2 pipe unit, with simplifi ed 3-way
on/off 230V valve, factory mountedCZK 12.497,- 12.853,- 13.428,- 14.141,- 14.415,- 15.484,- 16.279,- 17.347,- 21.979,- 24.473,-
Cooling capacity (Total) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02
Heating capacity (2-pipe at High Speed) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03
FWV**DFN, 4 pipe unit,
standard, without valves CZK 10.633,- 11.126,- 11.620,- 12.497,- 12.908,- 13.922,- 14.991,- 16.142,- 21.047,- 23.486,-
FWV**DFV, 4 pipe unit, with 3-way on/off 230V
valves, factory mounted CZK 22.116,- 22.691,- 23.185,- 23.979,- 24.473,- 25.487,- 26.555,- 27.624,- 33.187,- 35.681,-
FWV**DAFD6V3, 4 pipe unit, with simplifi ed 3-way
on/off 230V valves, factory mounted CZK 17.210,- 17.758,- 18.197,- 19.046,- 19.485,- 20.554,- 21.897,- 22.993,- 28.255,- 30.748,-
Cooling capacity (Total) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88
Heating capacity (4-pipe at High Speed) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35
Factory mounted options 01 15 02 25 03 35 04 06 08 10
3-way on/off 24V valve CZK on request
3-way proportional on/off valves CZK on request
2-way on/off 230V valve CZK on request
2-way on/off 24V valves CZK on request
2-way proportional on/off valve CZK on request
4-rows coil (for 2 pipe unit only) CZK on request
6-speeds fan motor CZK - on request - on r.
Electric heater (for 2 pipe unit only) CZK on request
Factory mounted options 01 15 02 25 03 35 04 06 08 10
FWEC1A Standard version CZK on request
FWEC2A Advanced version CZK on request
FWEC3A Advanced Plus version CZK on request
FWECSAP Power control board CZK on request
Notes:
Accessories as kits are included on page .
Additional single row h/e (-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for V valve. FWEC//A are not suitable to control V valve.
Controller FWECA is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.
FWL - D, Flexi type fan coil
FWL-D
Fan coil
Flexible unit FWL 01 15 02 25 03 35 04 06 08 10
FWL**DTN, 2 pipe unit,
standard, without valveCZK 9.647,- 10.140,- 10.770,- 11.209,- 11.921,- 12.853,- 13.565,- 14.552,- 19.622,- 22.198,-
FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve,
factory mounted CZK 15.922,- 16.416,- 16.991,- 17.484,- 18.197,- 19.211,- 20.060,- 21.047,- 26.610,- 29.186,-
FWL**DATD6V3, 2 pipe unit, with simplifi ed 3-way
on/off 230V valve, factory mountedCZK 12.853,- 13.346,- 13.977,- 14.497,- 15.210,- 16.142,- 16.991,- 17.978,- 23.185,- 25.706,-
Cooling capacity (Total) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02
Heating capacity (2-pipe at High Speed) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03
FWL**DFN, 4 pipe unit,
standard, without valvesCZK 11.209,- 11.784,- 12.140,- 13.072,- 13.565,- 14.991,- 15.785,- 16.854,- 22.417,- 24.829,-
FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves,
factory mountedCZK 22.554,- 23.048,- 23.486,- 24.418,- 24.911,- 26.336,- 27.131,- 28.118,- 34.338,- 36.750,-
FWL**DAFD6V3, 4 pipe unit, with simplifi ed 3-way
on/off 230V valves, factory mountedCZK 17.704,- 18.197,- 18.635,- 19.567,- 20.060,- 21.486,- 22.554,- 23.623,- 29.488,- 31.899,-
Cooling capacity (Total) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88
Heating capacity (4-pipe at High Speed) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35
Factory mounted options 01 15 02 25 03 35 04 06 08 10
3-way on/off 24V valve CZK on request
3-way proportional on/off valves CZK on request
2-way on/off 230V valve CZK on request
2-way on/off 24V valves CZK on request
2-way proportional on/off valve CZK on request
4-rows coil (for 2 pipe unit only) CZK on request
6-speeds fan motor CZK - on request - on r.
Electric heater (for 2 pipe unit only) CZK on request
Factory mounted options 01 15 02 25 03 35 04 06 08 10
FWEC1A Standard version CZK on request
FWEC2A Advanced version CZK on request
FWEC3A Advanced Plus version CZK on request
FWECSAP Power control board CZK on request
Notes:
Accessories as kits are included on page .
Additional single row h/e (-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for V valve. FWEC//A are not suitable to control V valve.
Controller FWECA is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list -
FWM-D
Fan coil
Flexible concealed unit FWM 01 15 02 25 03 35 04 06 08 10
FWM**DTN, 2 pipe unit,
standard, without valveCZK 7.783,- 8.276,- 8.578,- 9.208,- 9.482,- 10.195,- 10.633,- 11.620,- 15.347,- 17.402,-
FWM**DTV, 2 pipe unit,
with 3-way on/off 230V valve, factory mounted CZK 14.141,- 14.634,- 14.908,- 15.566,- 15.840,- 16.690,- 17.210,- 18.279,- 22.472,- 24.555,-
FWM**DATD6V3, 2 pipe unit, with simplifi ed
3-way on/off 230V valve, factory mounted CZK 11.072,- 11.565,- 11.839,- 12.497,- 12.771,- 13.483,- 14.141,- 15.128,- 18.992,- 21.047,-
Cooling capacity (Total) kW 1,54 1,74 1,96 2,42 2,93 3,51 4,33 4,77 6,71 8,02
Heating capacity (2-pipe at High Speed) kW 2,14 2,20 2,57 3,20 3,81 4,78 5,10 5,95 7,83 10,03
FWM**DFN, 4 pipe unit,
standard, without valves CZK 9.290,- 9.701,- 10.003,- 10.907,- 11.263,- 12.195,- 12.908,- 13.840,- 18.060,- 20.197,-
FWM**DFV, 4 pipe unit, with 3-way on/off 230V
valves, factory mountedCZK 20.828,- 21.266,- 21.540,- 22.472,- 22.774,- 23.705,- 24.473,- 25.322,- 30.255,- 32.393,-
FWM**DAFD6V3, 4 pipe unit, with simplifi ed 3-way
on/off 230V valves, factory mountedCZK 15.840,- 16.279,- 16.635,- 17.567,- 17.841,- 18.772,- 19.841,- 20.691,- 25.267,- 27.405,-
Cooling capacity (Total) kW 1,46 1,69 1,79 2,38 2,87 3,46 4,26 4,67 6,64 7,88
Heating capacity (4-pipe at High Speed) kW 1,90 2,02 2,01 2,92 3,08 4,80 5,05 5,30 7,91 8,35
Factory mounted options 01 15 02 25 03 35 04 06 08 10
3-way on/off 24V valve CZK on request
3-way proportional on/off valves CZK on request
2-way on/off 230V valve CZK on request
2-way on/off 24V valves CZK on request
2-way proportional on/off valve CZK on request
4-rows coil (for 2 pipe unit only) CZK on request
6-speeds fan motor CZK - on request - on r.
Electric heater (for 2 pipe unit only) CZK on request
FWECSAP - power control board CZK on request
Notes:
Accessories as kits are included on page .
Additional single row h/e (-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for V valve. FWEC//A are not suitable to control V valve.
Controller FWECA is necessary for proportional valve.
Cooling capacity is related to High Speed, standard unit.
FWM - D, Flexi concealed fan coil Accessories for FWV - FWL - FWM
FWV – FWL – FWM
Accessories
Accessories as a kit for FWV/FWL/FWM 1 15 2 25 3 35 4 6 8 10
Additional
heat
exchanger
The one-row heat exchanger is made of copper pipes and aluminum fi ns.Supplied as kit:1) heat exchanger2) fi xing plate3) self-tapping screws
ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6
CZK 1.973,- 2.357,- 2.576,- 3.426,-
Electric
Heater
Kit contains:1/ EEH Electric heater tape2/ E box = elec. wiring and operating relays3/ Set of heat-resistant plastic grilles (std grills need to be replaced)
Unit HeaterPower
consumptionOperting current
kw A
FW01+15 EEH01 1,0 4,5
FW02+25 EEH02 1,5 6,8
FW03+35 EEH03 1,6 7,3
FW04+06 EEH06 2,0 9,1
FW08+10 EEH10 3,0 13,6
EEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6
CZK 8.002,- 8.002,- 8.441,- 8.989,- 9.290,-
2-pipe
3-ways
230V on/off
valve kit
Kit contains:1/ 3way Valve BodySIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 2pcs of lockshield valve
E2MV03A6 E2MV06A6 E2MV10A6
CZK 6.385,- 6.385,- 6.769,-
4-pipe
3-ways
230V on/off
valve kit
Kit contains:1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ 2 pcs of Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 4pcs of lockshield valve
E4MV03A6 E4MV06A6 E4MV10A6
CZK 11.565,- 11.565,- 12.168,-
2-ways
230V on/off
valve kit on
cooling heat
exchanger
Kit contains:1/ 2way Valve BodySIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MV2B07A6 E2MV2B10A6
CZK 2.741,- 2.741,-
2-ways
230V on/off
valve kit on
additional
heat
exchanger
Kit contains:1/ 2way Valve BodySIZE 1÷10 valve = 1/2” (kvs=1,7)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MV2B07A6
CZK 2.741,-
2-pipe
simplifi ed
3-ways 230V
on/off valve
kit
Kit contains:1/ 3way Valve BodySIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MVD03A6 E2MVD06A6 E2MVD10A6
CZK 3.727,- 3.809,- 3.892,-
4-pipe
simplifi ed
3-ways 230V
on/off valve
kit
Kit contains:1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ 2 pcs of Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E4MVD03A6 E4MVD06A6 E4MVD10A6
CZK 6.933,- 7.070,- 7.153,-
2-pipe
3-ways 24V
on/off valve
kit
Kit contains:1/ 3way Valve BodySIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 2pcs of lockshield valve
E2M2V03A6 E2M2V06A6 E2M2V10A6
CZK 6.385,- 6.385,- 6.769,-
Applied Systems Price list -
Accessories for FWV - FWL - FWM
FWV – FWL – FWM
Accessories
Accessories as a kit for FWV/FWL/FWM 1 15 2 25 3 35 4 6 8 10
4-pipe
3-ways 24V
on/off valve
kit
Kit contains:1/ 2 pcs of 3way Valve Body SIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ 2 pcs of Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 4pcs of lockshield valve
E4M2V03A6 E4M2V06A6 E4M2V10A6
CZK 11.565,- 11.565,- 12.168,-
2-pipe
3-ways
proportional
valve kit
Kit contains:1/ 3way Valve BodySIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ Electronic valve actuatorProportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal3/ Thermal insulation on pipes and valve4/ 2pcs of lockshield valve
E2MPV03A6 E2MPV06A6 E2MPV10A6
CZK 10.195,- 9.975,- 10.277,-
4-pipe
3-ways
proportional
valve kit
Kit contains:1/ 2 pcs 3way Valve BodySIZE 1÷35 valve = 1/2” (kvs=1,7) SIZE 4÷10 valve = 3/4” (kvs=2,8)2/ 2 pcs Electronic valve actuatorProportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal3/ Thermal insulation on pipes and valve4/ 4pcs of lockshield valve
E4MPV03A6 E4MPV06A6 E4MPV10A6
CZK 18.663,- 18.800,- 18.964,-
2-ways 24V on/
off valve kit on
cooling heat
exchanger
Kit contains:1/ 2way Valve BodySIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2M2V207A6 E2M2V210A6
CZK 2.741,- 2.741,-
2-ways 24V on/
off valve kit
on additional
heat
exchanger
Kit contains:1/ 2way Valve BodySIZE 1÷10 valve = 1/2” (kvs=1,7)2/ Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2M2V207A6
CZK 2.741,-
2-ways
proportional
valve kit on
cooling heat
exchanger
Kit contains:1/ 2way Valve BodySIZE 1÷6 valve = 1/2” (kvs=1,7) SIZE 8÷10 valve = 3/4” (kvs=2,8)2/ Electronic valve actuatorProportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MPV207A6 E2MPV210A6
CZK 7.070,- 7.070,-
2-ways
proportional
valve kit on
additional
heat
exchanger
Kit contains:1/2way Valve BodySIZE 1÷10 valve = 1/2” (kvs=1,7)2/ Electronic valve actuatorProportional activation - power supply 24V - total opening time cca 8 second - 0-10V control signal3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MPV207A6
CZK 7.070,-
Fan stop
thermostat
To prevent ventilating cold air during the heating stage If the water temperature inside the heat exchanger is lower than 42°C.(The bracket to fi x fan stop thermostat is included in the kit.)Only required in combination with electromechanical controller
YFSTA6
CZK 521,-
Air intake &
discharge
grille
S: Back suction grille fi xed fi ns, made of anodised aluminium complete with fi lter and galvanised steel plate subframe and recyclable acrylic fi bre air fi lter.
D: Discharge grille with double row of anodised aluminium swinging fi ns, complete with galvanised steel plate subframe.
EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6
CZK 5.481,- 6.632,- 8.605,- 10.195,-
Accessories as a kit for FWV/FWL/FWM 1 15 2 25 3 35 4 6 8 10
Supporting
feet
Kit contains:
ESFV ESFVG FWV FWM
2 2
2 2 -
0 1 -
4,2 x 13 mm 4 8
2,9 x 9,5 mm 4 4
ESFV06A6 ESFV10A6
CZK 685,- 685,-
Supporting
feet & grille
ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6
CZK 987,- 1.206,- 1.370,- 1.891,-
Fresh air
intake
To prevent the water from freezing inside the heat exchanger during winter.Close the outdoor air inlet louvre when the system is not operational or use an anti-freeze solution.
EFA02A6 EFA03A6 EFA06A6 EFA10A6
CZK 2.357,- 2.576,- 2.905,- 3.206,-
Rear panel
It is supplied for installation of units, in case rear side can be seen (example: installation at the back of glass windows).Unit, in case of rear panel installation, can not be fi xed to wall.Kit consists of: 1. rear upper closing panel 2. rear lower closing panel 3. screws
ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6
CZK 1.206,- 1.288,- 1.589,- 1.973,-
Plenum box
with circular
connections
(only for
FWM-D)
Unit size Plenum box Ø [mm] x n
Size 01-02 EPCC02A6 180 x 2
Size 25-03 EPCC03A6 180 x 2
Size 35-06 EPCC06A6 180 x 3
Size 08-10 EPCC10A6 180 x 4
EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6
CZK 2.823,- 3.124,- 3.946,- 5.399,-
Vertical
auxiliary
drainpan
Install it to collect condensation. Used for vertical FCUs
EDPVB6
CZK 219,-
Horizontal
auxiliary
drainpan
Install it to collect condensation. Used for horizontal FCUs
EDPHB6
CZK 219,-
Controller
electro-
mechanical,
Built in
For installation on board the unit is used for:Manually changing the operation fan speed of the unit; Automatically setting the room temperature by operating the motor-ventilator of the unit, both during cooling and heating. - 4 position rotary speed selector switch
(three speeds + stop)- Cooling/Heating operation selector- Manual set thermostat
ECFWMB6
CZK 1.288,-
Wired remote
controller,
Standard
version
Onboard or wall mounted installation: - Management of AC 3-speeds fan motor
(on/off and automatic speed change)- Management of on/off valve- Management of electric heater- Cooling / heating mode swithcing based
on air / water temperature- Clean contact for remote activation (e.g.
window contact, remote on/off )
FWEC1A
CZK 3.042,-
Wired remote
controller,
Advanced
version
All functionality of FWEC1A, but additionally:- Management of AC 4-speeds fan motor
(on/off and automatic speed change)- Air relative humidity control- Master & Slave System on serial RS485
(Modbus communication protocol)- Integration in BMS
FWEC2A
CZK 4.412,-
Wired remote
controller,
Advanced Plus
version
All functionality of FWEC2A, but additionally:- Management of BLDC fan motor- Management of proportional valve- Weekly timer programmed operating
mode- Confi gurable digital outputs
FWEC3A
CZK 6.002,-
Accessories for FWV - FWL - FWM
FWV – FWL – FWM
Accessories
Applied Systems Price list -
Accessories for FWV - FWL - FWM
FWV – FWL – FWM
Accessories
Accessories as a kit for FWV/FWL/FWM 1 15 2 25 3 35 4 6 8 10
FWECSA
Split type
controller
Power control boardFWECSAP
CZK 4.577,-
Control panel for remote or on board installation (connected to the power control board)All functionality of FWEC3A, but additionally:- Master & Slave System on Conveyed
Waves (CW)
FWECSAC
CZK 3.426,-
On board
mounting kit,
for FWEC*A,
remote
airprobe incl.
To install FWEC1/2/3A thermostat on board.(left or right side)
Use it only for FWV / FWZ orFWL / FWR
Side doors
on left & right side
Controllers
Optional
Low wall unit Flexi type
FWECKA
CZK 521,-
Wall mounting
kit (spacing
collar),
for FWEC 1A
/2A and 3A
Wall mounting kit (spacing collar),for FWEC 1A /2A and 3A
FWFCKA
CZK 384,-
Temperature
sensor kit, for
FWEC*A
FWTSK sensor should be connected to the FWEC*A remote control using the supplied cable as accessory and, in case of prolongations, a shielded cable only.The sensor cable (1,5 m) can be cut to measure if necessary. Sensor must be positioned on the heat exchanger OR atthe valve inlet (with or without vlave installation)
FWTSKA
CZK 384,-
Relative
humidity
sensor kit ,
for FWEC2A
and FWEC3A
(tempereture
sensor kit is
required)
Bound together the air temperature remote probe, the installation of the humidity remote probe allows: - To display on the controller the
environment humidity - To select the Dehumidifi cation function
The dehumidifi cation function, available only in the cooling mode, uses the terminal to reduce the environmental humidity by approximately 10% compared to the humidity present at the moment of function selection.
FWHSKA
CZK 685,-
Master / Slave
interface
The EPIMSB6 Master/slave interface is used for connecting up to 4 units in parallel to one controller FWEC(1,2,3)A. With the new split controller FWECSA to connect more unit you don’t need EPIMSB6 with a saving in the installation time/cost.The capacity of the EPIMSB6 contacts is max 4 x 3 A.
EPIMSB6
CZK 4.494,-
FWZ-A, Floor standing fan coil with DC fan motor
FWZ-A
Fan coil
Low sound level and up to % energy saving thanks to the BLDC
motor technology
Low Wall unit with DC fan motor FWZ 02 03 06 08
FWZ**ATN, 2 pipe unit,
standard, without valveCZK 15.210,- 16.059,- 18.635,- 23.267,-
FWZ**ATV, 2 pipe unit,
with 3-way on/off 230V valve, factory mountedCZK 21.486,- 22.335,- 25.048,- 30.255,-
FWZ**AATD6V3, 2 pipe unit, with simplifi ed 3-way
on/off 230V valve, factory mountedCZK 18.416,- 19.348,- 22.061,- 26.829,-
Cooling capacity (Total) kW 2,64 4,96 6,32 10,08
Heating capacity (2-pipe at High Speed) kW 3,47 6,40 7,51 11,18
FWZ**AFN, 4 pipe unit,
standard, without valves CZK 16.553,- 17.621,- 20.828,- 25.624,-
FWZ**AFV, 4 pipe unit, with 3-way on/off 230V
valves, factory mounted CZK 27.898,- 28.912,- 32.173,- 37.545,-
FWZ**AAFD6V3, 4 pipe unit, with simplifi ed 3-way
on/off 230V valves, factory mounted CZK 23.048,- 24.062,- 27.624,- 32.694,-
Cooling capacity (Total) kW 2,43 4,96 6,32 10,08
Heating capacity (4-pipe at High Speed) kW 2,46 4,19 6,45 10,06
Factory mounted options 02 03 06 08
3-way on/off 24V valve CZK on request
2-way on/off 230V valve CZK on request
2-way on/off 24V valves CZK on request
4-rows coil (for 2 pipe unit only) CZK on request
Electric heater (for 2 pipe unit only) CZK on request
Factory mounted options 02 03 06 08
FWEC3A Advanced Plus version CZK on request
FWECSAP power control board CZK on request
Notes:
Accessories as kits are included on page .
Additional single row h/e (-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for V valve. FWECA are not suitable to control V valve.
Controller FWECA is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list -
FWR-A, Flexi type fan coil with DC fan motor
FWR-A
Fan coil
Low sound level and up to % energy saving thanks to the BLDC
motor technology
FLEXI type unit with DC fan motor FWR 02 03 06 08
FWR**ATN, 2 pipe unit,
standard, without valveCZK 15.840,- 17.210,- 19.841,- 25.322,-
FWR**ATV, 2 pipe unit,
with 3-way on/off 230V valve, factory mountedCZK 22.116,- 23.486,- 26.336,- 32.338,-
FWR**AATD6V3, 2 pipe unit, with simplifi ed 3-way
on/off 230V valve, factory mountedCZK 19.129,- 20.417,- 23.267,- 28.912,-
Cooling capacity (Total) kW 2,64 4,96 6,32 10,08
Heating capacity (2-pipe at High Speed) kW 3,47 6,40 7,51 11,18
FWR**AFN, 4 pipe unit,
standard, without valves CZK 17.402,- 18.690,- 21.979,- 27.981,-
FWR**AFV, 4 pipe unit, with 3-way on/off 230V
valves, factory mounted CZK 28.693,- 30.036,- 33.324,- 39.902,-
FWR**AAFD6V3, 4 pipe unit, with simplifi ed 3-way
on/off 230V valves, factory mounted CZK 23.842,- 25.185,- 28.748,- 35.051,-
Cooling capacity (Total) kW 2,43 4,96 6,32 10,08
Heating capacity (4-pipe at High Speed) kW 2,46 4,19 6,45 10,06
Factory mounted options 02 03 06 08
3-way on/off 24V valve CZK on request
2-way on/off 230V valve CZK on request
2-way on/off 24V valves CZK on request
4-rows coil (for 2 pipe unit only) CZK on request
Electric heater (for 2 pipe unit only) CZK on request
Factory mounted options 02 03 06 08
FWEC3A Advanced Plus version CZK on request
FWECSAP power control board CZK on request
Notes:
Accessories as kits are included on page .
Additional single row h/e (-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for V valve. FWEC//A are not suitable to control V valve.
Controller FWECA is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.
FWS-A
Fan coil
Low sound level and up to % energy saving thanks to the BLDC
motor technology
FWS-A, Flexi type fan coil with DC fan motor
FLEXI type unit with DC fan motor FWS 02 03 06 08
FWS**ATN, 2 pipe unit,
standard, without valveCZK 13.620,- 14.552,- 16.690,- 20.828,-
FWS**ATV, 2 pipe unit,
with 3-way on/off 230V valve, factory mountedCZK 19.923,- 20.773,- 23.185,- 27.843,-
FWS**AATD6V3, 2 pipe unit, with simplifi ed 3-way
on/off 230V valve, factory mountedCZK 16.854,- 17.758,- 20.115,- 24.418,-
Cooling capacity (Total) kW 2,64 4,96 6,32 10,08
Heating capacity (2-pipe at High Speed) kW 3,47 6,40 7,51 11,18
FWS**AFN, 4 pipe unit,
standard, without valves CZK 15.045,- 16.333,- 18.690,- 23.404,-
FWS**AFV, 4 pipe unit, with 3-way on/off 230V
valves, factory mounted CZK 26.336,- 27.624,- 30.036,- 35.325,-
FWS**AAFD6V3, 4 pipe unit, with simplifi ed 3-way
on/off 230V valves, factory mounted CZK 21.486,- 22.774,- 25.487,- 30.474,-
Cooling capacity (Total) kW 2,43 4,96 6,32 10,08
Heating capacity (4-pipe at High Speed) kW 2,46 4,19 6,45 10,06
Factory mounted options 02 03 06 08
3-way on/off 24V valve CZK on request
2-way on/off 230V valve CZK on request
2-way on/off 24V valves CZK on request
4-rows coil (for 2 pipe unit only) CZK on request
Electric heater (for 2 pipe unit only) CZK on request
Factory mounted options 02 03 06 08
FWEC3A Advanced Plus version CZK on request
FWECSAP power control board CZK on request
Notes:
Accessories as kits are included on page .
Additional single row h/e (-row coil) can not be used in combination with electric heater.
Independent power supply is necessary for V valve. FWECA are not suitable to control V valve.
Controller FWECA is necessary to control DC fan motor.
Cooling capacity is related to High Speed, standard unit.
Applied Systems Price list -
Accessories for FWZ - FWR - FWS
FWZ - FWR - FWS
Accessories
Accessories as a kit for FWZ/FWR/FWS 02 03 06 08
Additional
heat
exchanger
The one-row heat exchanger is made of copper pipes and aluminum fi ns.Supplied as kit:1) heat exchanger2) fi xing plate3) self-tapping screws
ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6
CZK 1.973,- 2.357,- 2.576,- 3.426,-
Electric heater
Kit contains:1/ EEH Electric heater tape2/ E box = elec. wiring and operating relays3/ Set of heat-resistant plastic grilles (std grills need to be replaced)
Unit HeaterPower
consumptionOperting current
kw A
FW02 EEH02 1,5 6,8
FW03 EEH03 1,6 7,3
FW06 EEH06 2,0 9,1
FW08 EEH10 3,0 13,6
EEH02A6 EEH03A6 EEH06A6 EEH10A6
CZK 8.002,- 8.441,- 8.989,- 9.290,-
2-pipe 3-ways
230V on/off
valve kit
Kit contains:1/ 3way Valve BodySIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 2pcs of lockshield valve
E2MV03A6 E2MV06A6 E2MV10A6
CZK 6.385,- 6.385,- 6.769,-
4-pipe 3-ways
230V on/off
valve kit
Kit contains:1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8)2/ 2 pcs of Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 4pcs of lockshield valve
E4MV03A6 E4MV06A6 E4MV10A6
CZK 11.565,- 11.565,- 12.168,-
2-ways 230V
on/off valve kit
cooling h/e
Kit contains:1/ 2way Valve BodySIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MV2B07A6 E2MV2B10A6
CZK 2.741,- 2.741,-
2-ways 230V
on/off valve kit
additional h/e
Kit contains:1/ 2way Valve BodySIZE 2÷8 valve = 1/2” (kvs=1,7)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MV2B07A6
CZK 2.741,-
2-pipe
simplifi ed
3-ways 230V
on/off valve kit
Kit contains:1/ 3way Valve BodySIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2MVD03A6 E2MVD06A6 E2MVD10A6
CZK 3.727,- 3.809,- 3.892,-
4-pipe
simplifi ed
3-ways 230V
on/off valve kit
Kit contains:1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8)2/ 2 pcs of Electrothermal actuatorON/OFF activation - power supply 230V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E4MVD03A6 E4MVD06A6 E4MVD10A6
CZK 6.933,- 7.070,- 7.153,-
2-pipe 3-ways
24V on/off
valve kit
Kit contains:1/ 3way Valve BodySIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 2pcs of lockshield valve
E2M2V03A6 E2M2V06A6 E2M2V10A6
CZK 6.385,- 6.385,- 6.769,-
Accessories for FWZ - FWR - FWS
FWZ - FWR - FWS
Accessories
Accessories as a kit for FWZ/FWR/FWS 02 03 06 08
4-pipe 3-ways
24V on/off
valve kit
Kit contains:1/ 2 pcs of 3way Valve Body SIZE 2÷3 valve = 1/2” (kvs=1,7) SIZE 6÷8 valve = 3/4” (kvs=2,8)2/ 2 pcs of Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ Thermal insulation on pipes and valve4/ 4pcs of lockshield valve
E4M2V03A6 E4M2V06A6 E4M2V10A6
CZK 11.565,- 11.565,- 12.168,-
2-ways 24V on/
off valve kit
cooling h/e
Kit contains:1/ 2way Valve BodySIZE 2÷6 valve = 1/2” (kvs=1,7) SIZE 8 valve = 3/4” (kvs=2,8)2/ Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2M2V207A6 E2M2V210A6
CZK 2.741,- 2.741,-
2-ways 24V on/
off valve kit
additional h/e
Kit contains:1/ 2way Valve BodySIZE 2÷8 valve = 1/2” (kvs=1,7)2/ Electrothermal actuatorON/OFF activation - power supply 24V - total opening time cca 4 minutes - NC (Normally Closed)3/ without thermal insulation4/ NO lockshield /shut of valve in the kit
E2M2V207A6
CZK 2.741,-
Air intake &
discharge
grille
S: Back suction grille fi xed fi ns, made of anodised aluminium complete with fi lter and galvanised steel plate subframe and recyclable acrylic fi bre air fi lter.
D: Discharge grille with double row of anodised aluminium swinging fi ns, complete with galvanised steel plate subframe.
EAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6
CZK 5.481,- 6.632,- 8.605,- 10.195,-
Supporting
feet
Kit contains:
ESFV ESFVG FWZ FWS
2 2
2 2 -
0 1 -
4,2 x 13 mm 4 8
2,9 x 9,5 mm 4 4
ESFV06A6 ESFV10A6
CZK 685,- 685,-
Supporting
feet & grille
ESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6
CZK 987,- 1.206,- 1.370,- 1.891,-
Fresh air
intake
To prevent the water from freezing inside the heat exchanger during winter.Close the outdoor air inlet louvre when the system is not operational or use an anti-freeze solution.
EFA02A6 EFA03A6 EFA06A6 EFA10A6
CZK 2.357,- 2.576,- 2.905,- 3.206,-
Rear panel
It is supplied for installation of units, in case rear side can be seen (example: installation at the back of glass windows).Unit, in case of rear panel installation, can not be fi xed to wall.Kit consists of: 1. rear upper closing panel 2. rear lower closing panel 3. screws
ERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6
CZK 1.206,- 1.288,- 1.589,- 1.973,-
Plenum box
with circular
connections
(only for
FWS-A)
Unit size Plenum box Ø [mm] x n
Size 02 EPCC02A6 180 x 2
Size 03 EPCC03A6 180 x 2
Size 06 EPCC06A6 180 x 3
Size 08 EPCC10A6 180 x 4
EPCC02A6 EPCC03A6 EPCC06A6 EPCC10A6
CZK 2.823,- 3.124,- 3.946,- 5.399,-
Vertical
auxiliary
drainpan
Install it to collect condensationcondensation. Used for vertical FCUs
EDPVB6
CZK 219,-
Horizontal
auxiliary
drainpan
Install it to collect condensation. Used for horizontal FCUs
EDPHB6
CZK 219,-
Applied Systems Price list -
Accessories for FWZ - FWR - FWS
FWZ - FWR - FWS
Accessories
Accessories as a kit for FWZ/FWR/FWS 02 03 06 08
Wired remote
controller,
Advanced Plus
version
All functionality of FWEC1A/2A (see page 39), but additionally:- Management of BLDC fan motor- Management of proportional valve- Weekly timer programmed operating
mode- Confi gurable digital outputs
FWEC3A
CZK 6.002,-
FWECSA
Split type
controller
Power control boardFWECSAP
CZK 4.577,-
Control panel for remote or on board installation (connected to the power control board)All functionality of FWEC3A, but additionally:- Master & Slave System on Conveyed
Waves (CW)
FWECSAC
CZK 4.577,-
On board
mounting kit,
for FWEC*A,
remote
airprobe incl.
To install FWEC1/2/3A thermostat on board.(left or right side)
Use it only for FWV / FWZ orFWL / FWR
Side doors
on left & right side
Controllers
Optional
Low wall unit Flexi type
FWECKA
CZK 521,-
Wall mounting
kit (spacing
collar),
for FWEC 1A
/2A and 3A
Wall mounting kit (spacing collar),for FWEC 1A /2A and 3A
FWFCKA
CZK 384,-
Temperature
sensor kit, for
FWEC*A
FWTSK sensor should be connected to the FWEC*A remote control using the supplied cable as accessory and, in case of prolongations, a shielded cable only.The sensor cable (1.5 m) can be cut to measure if necessary. Sensor must be positioned on the heat exchanger OR atthe valve inlet (with or without vlave installation)
FWTSKA
384,-
Relative
humidity
sensor kit ,
for FWEC2A
and FWEC3A
(tempereture
sensor kit is
required)
Bound together the air temperature remote probe, the installation of the humidity remote probe allows: - To display on the controller the
environment humidity - To select the Dehumidifi cation function
The dehumidifi cation function, available only in the cooling mode, uses the terminal to reduce the environmental humidity by approximately 10% compared to the humidity present at the moment of function selection.
FWHSKA
CZK 685,-
Air Handling Units - AHU
D-AHU Modular Series
D-AHU Modular specifi cation:
Panel type:
Internal Skin Material: Aluzinc®
External Skin fi nishing: Aluzinc® or Pre-Painted
Insulation material: Mineral Wool or Polyurethane
Panel Type: SP
Construction Structure:
Frame: Anodized Aluminum
Frame Type: Internal Rounded
Main Components & Calculation input:
Heat Wheel: Sensible type
Fans (Standard Pressure): EC Fan IE Mot.
Unit Installation: Indoor (without roof )
Filters Effi ciency: Supply: F as minimum
Return: M as minimum
Main Module Confi guration:
Plug & Play factory mounted Controls
Size 1 2 3 4 5 6 7 8 9 10
Main Module CZK 352.319,- 364.870,- 410.308,- 449.771,- 490.248,- 522.065,- 577.725,- 673.122,- 773.616,- 865.861,-
Size 1 2 3 4 5 6 7 8 9 10
Mode
Cooling Coil CZK 59.770,- 47.356,- 54.920,- 64.539,- 71.417,- 84.736,- 88.080,- 116.252,- 124.254,- 137.272,-
Cooling+Heating
CoilCZK 84.243,- 64.018,- 72.788,- 84.956,- 93.314,- 107.345,- 111.401,- 143.246,- 155.003,- 171.528,-
Dx HP CZK 76.734,- 73.254,- 80.598,- 120.609,- 126.145,- 135.353,- 139.820,- 155.222,- 163.964,- on request
Size 1 2 3 4 5 6 7 8 9 10
Three way mixing box CZK 29.433,- 29.844,- 32.064,- 36.175,- 38.449,- 39.573,- 45.739,- 52.015,- 56.427,- 61.305,-
Size 1 2 3 4 5 6 7 8 9 10
Outdoor Kit (Roof) CZK 3.946,- 4.357,- 5.481,- 6.933,- 9.564,- 10.277,- 11.236,- 13.785,- 14.579,- 15.895,-
Size 1 2 3 4 5 6 7 8 9 10
Additional F9 fi ne fi lter in the main
fi lter module on supply side onlyCZK 4.056,-
On
request6.796,- 8.057,- 10.798,- 10.798,- 12.058,- 19.293,- 19.293,- 41.683,-
Size 1 2 3 4 5 6 7 8 9 10
Sorption Type Heat Wheel
(to replace sensible type on main
module)
CZK 34.147,- 38.751,- 49.082,- 64.840,- 73.911,- 79.529,- 95.123,- 108.058,- 129.078,- 176.844,-
Size 1 2 3 4 5 6 7 8 9 10
Bacnet Module (for ITM Daikin) CZK 7.701,-
MODBUS Communication module CZK 4.659,-
Size 1 2 3 4 5 6 7 8 9 10
Airfl ow m3/h 1200 1700 2700 4100 5500 6100 7000 9100 11500 15000
Temp effi ciency winter % 81.3 81.1 81.4 81.6 82.6 81.2 82.7 81.4 81.5 83.2
ESP nominal Pa 200 200 200 200 200 200 200 200 200 200
Current nominal A 2.66 3.9 6.3 2.98 4 4.74 4.76 5.54 8.72 10.2
Power input nominal kW 0.62 0.89 1.5 1.98 2.68 2.96 3.3 3.76 5.48 7.04
SFPv kW/m3/s 1.87 1.89 1.99 1.74 1.75 1.75 1.7 1.49 1.72 1.69
Electrical supply V-ph-Hz 230-1-50 230-1-50 230-1-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
Lenght mm 1700 1700 1800 1920 2080 2280 2400 2450 2280 2400
Depth mm 720 820 990 1200 1400 1400 1600 1940 1940 2300
Height overall mm 1320 1320 1540 1740 1740 1920 1920 2180 2460 2570
Weight kg 325 350 475 575 750 790 950 1330 1410 1750
Sound level - Lp* dB(A) 40 42 42 45 46 44 43 43 45 45
* Sound pressure level radiated from unit at meter and according to ISO (supply outlet ducted)
Main module nominal Performances
Applied Systems Price list -
Products overview Air cooled chillers and condensing units
NEW
Air cooled and condensing units
Re
frig
era
nt
typ
e *
Re
frig
era
nt
circ
uit
s
Inv
ert
er
Fre
e c
oo
lin
g
CompressorWater heat
exchangerEffi ciency version Sound version
Sw
ing
Scr
oll
Scr
ew
Pla
te *
*
Sin
gle
pa
ss s
he
ll
an
d t
ub
e
Sta
nd
ard
Hig
h
Pre
miu
m
Hig
h a
mb
ien
t
Sta
nd
ard
Lo
w
Re
du
ced
Ex
tra
lo
w
Cooling only0 17,5 200 500 1.000 2.000
EWAQ~ADVP R-410A 1BPHE
EWAQ~ACV3/ACW1 R-410A 1BPHE
EWAQ~BA* R-410A 1-2BPHE
EWAQ~G- R-410A 1BPHE
EWAQ~E- R-410A 1
EWAQ~F- R-410A 2
EWAD~E- R-134a 1
EWAD~D- R-134a 2
EWAD~C- R-134a 2-3
EWAD~CZ R-134a 2-3
EWAD~CF R-134a 2
EWAD~TZ R-134a 1-2
EWAD-TZ B R-134a 1-2
Heat pump0 17,5 200 500 1.000 2.000
EWYQ~ADVP R-410A 1BPHE
EWYQ~ACV3/ACW1 R-410A 1BPHE
EWYQ~BA* R-410A 1-2BPHE
SEHVX-AAW
SERHQ-AAW1 R-410A 1BPHE
EWYQ~G- R-410A 1BPHE
EWYQ~F- R-410A 2
EWYD~BZ R-134a 2-3
Condensing unit0 17,5 200 500 1.000 2.000
ERAD~E- R-134a 1
5,6~8,2
16,6~64,5
8,6~17,0
116~488
165~672
98~411
177~620
617~2.002
170~710
169~1.100
696~1.795
172~334
5,3~7,2
602~1.555
5,3~7,2
247~580
271~618
173~674
158~624
8,6~17,0
20,7~74,3
16,6~64,5
16,2~63,7
21,3~63,7
Cooling capacity (kW)
Heating capacity (kW)
9,9~14,8
69,3~154
82,2~170
75,2~165
Applied Systems Price list -
Water cooled and condenserless units
Products overview
Re
frig
era
nt
Ty
pe
*
Re
frig
era
nt
circ
uit
s
Inv
ert
er
Compressor Water heat exchanger Effi ciency versionSound
version
Scr
oll
Scr
ew
Ce
ntr
ifu
ga
l
Pla
te *
*
Sin
gle
pa
ss s
he
ll
an
d t
ub
e
Sh
ell
an
d
tub
e
Sta
nd
ard
Hig
h
Pre
miu
m
Sta
nd
ard
Water cooled chillers (Cooling only & Heating only)0 17,5 200 500 1.000 2.000 21.800
EWWP~KBW1N R-407C 1-2-4-6
EWHQ~G- R-410A 1
EWWQ~G- R-410A 1
EWWQ~L- R-410A 2
EWWD~J- R-134a 1-2
EWWD~G- R-134a 1-2
EWWD~I- R-134a 1-2-3
Water cooled chillers (Cooling only)0 17,5 200 500 1.000 2.000 21.800
EWWD-VZ R-134a1-60
2 Flooded
EWWQ~B- R-410A 1-2
Condenserless chillers0 17,5 200 500 1.000 2.000 21.800
EWLP~KBW1N R-407C 1-2BPHE
EWLQ~G- R-410A 1
EWLQ~L- R-410A 2
EWLD~J- R-134a 1-2
EWLD~G- R-134a 1-2
EWLD~I- R-134a 1-2-3
Water cooled centrifugal chillers0 17,5 200 500 1.000 2.000 21.800
EWWD~FZ R-134a 1 Flooded
DWSC
DWDCR-134a 1 optional
Flooded
6,000 RT
CENTRIFUGAL R-134a
2
per
chiller
Flooded
NEW
* (GWP) : R-410A (2087.5), R-134a (1430), R-407C (1773.9) - ** BPHE: Brazed plate heat exchanger
Water cooled and condenserless units
12,9~194
165~602
332~1.503
600~9.000
379~2.156
449~2.100
12,1~62,4
110~529
86,5~346
173~676
160~524
315~1.433
113~1.054
[ 2 x 10.900 ]
142~681
209~743
16,7~249
424~1.951
Cooling capacity (kW)
Heating capacity (kW)
120~568
300~4.500
21.800
87,3~352
118~462
93,7~370
187~721
118~468
234~914
Applied Systems Price list -
COOLING TOWER
70-9.200 kW
On request we can off er you the most suita-
ble cooling tower for your application.
For correct selection we need following info:
Heat rejection capacity (kW) or chiller type
and working conditions
Liquid inlet and outlet temperature
Liquid type
Maximum/Minimum ambient temperature
Maximum sound level
Space restrictions
AIR COOLER
1-162 kW
On request we can off er you the most
suitable air cooler for your application
based on a brine/water solution.
AIR HANDLING
UNIT
500-140.000 m3/h
On request we can off er you the most
suitable air handling unit for your
application.
Air handling units for fi ltering,
heating, cooling, humidifying, and air
drying
Air handling units with heat recovery
Air handling units for outdoor
installation
Air handling units in hygienic
execution for hospital and clean room
Air handling units with indirect gas
fi red heating
Air handling units for swimming pool
applications
Air handling units with higher air
volumes manufactured on request
Air handling units with thermal
uncoupled frame
DRY COOLER &
CONDENSER
3-2.400 kW
On request we can off er you the most
suitable dry cooler and condenser for
your application.
For correct selection we need following
info:
Heat rejection capacity (kW) or chiller
type and working conditions
Liquid inlet and outlet temperature
(dry cooler)
Liquid type (dry cooler)
Condensing temperature (condenser)
Refrigerant type and number of
circuits (condenser)
Maximum/Minimum ambient
temperature
Maximum sound level
Space restrictions
Total solution products
COMPRESSOR
Inspection/repair/overhaul
Inspection
Inspection fee/
compressor*on request
Repair
Repair cost/
compressor*
After inspection, on
quotation base
Overhaul
Overhaul cost/
compressor*on request
To extend the lifetime of your
compressor, Daikin off ers a compressor
overhaul service as preventive
maintenance.
In case of broken compressor, Daikin
can off er an inspection to determine
whether the compressor is repairable
or not. Based on the fi ndings the
broken parts will be replaced and
the compressor will be restored into
operational condition.
Remarks
The above is only valid for DAIKIN semi-hermetic
compressors
* Excluding transport cost and other site related
costs
MENTIONED CAPACITIES, EFFICIENCY RATIOS, SOUND POWER
LEVELS, DIMENSIONS Weights are indicative and valid under the following conditions:
Chillers
Air cooled units
Cooling 7 °C / 12 °C water 35 °C ambient temp
Heating 40 °C / 45 °C water 7 °C ambient temp
Heat recovery 7 °C / 12 °C water 40°C / 45°C heat recovery 35 °C ambient temp
Condenserless units Cooling 7 °C / 12 °C water 45 °C condensing temp / 5 K subcooling
Water cooled unitsCooling 7 °C / 12 °C evaporator water 30 °C / 35 °C condenser water
Heating 7 °C / 12 °C evaporator water 40 °C / 45 °C condenser water
Rooftops
Cooling: indoor temperature: 27 °C db / 19 °C wb outdoor temperature: 35 °C
Heating: indoor temperature: 20 °C db outdoor temperature: 7 °C db / 6 °C wb
Condensing units
Cooling: evaporation temperature: 6 °C outdoor temperature: 35 °C on-coil temperature: 27 °CDB / 19 °CWB
Heating: condensing temperature: 46 °C outdoor temperature: 7 °C on-coil temperature: 20 °CDB
General:
evaporator superheat: 5K
condenser sub-cool: 3K
7,5 m equivalent refrigerant piping
0 m level diff erence
Fan coil units
Cooling:Room temperature DB/WB: 27 °C/19 °C
Entering/Leaving water temperature: 7 °C/12 °C
Heating:Room temperature: 20 °C
Entering water temperature: 50 °C (2-pipe,water fl ow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C)
Measuring conditions
Applied Systems Price list -
Service
Saving energy doesn’t stop with the purchase or
installation of energy-effi cient equipment; it has to be
kept running under optimum conditions.
Good maintenance and servicing are key elements in
ensuring the maximum performance.
Are you sure the fi lters are clean and none of the
components are defective?
Are all of your settings correct?
Any of these things may lead to a reduced level of
comfort. And while you may not notice the diff erence
right away, you will certainly notice it at the end of
the year – when you pay your energy bill.
Spare parts Repair service
Installation support CommissioningMaintenance plan
Intelligent remote
monitoring
24 / 7
Upgrading /
optimisation
Optimisation and upgrades
Keep the installation in top condition
Parts andrepairs
Daikin Services
Our Daikin design team is constantly striving to
improve the energy effi ciency of our systems.
We at Daikin Service are here to support you in
keeping your units up and running effi ciently by
means of optimised commissioning and start-up,
regular and preventative maintenance, remote
monitoring, improving the performance of units, and
providing cost eff ective upgrades to benefi t from
the effi ciency gains from our latest state of the art
technology.
DescriptionMaterial Number
COMMISSIONING
PRICE [CZK]Type Nr. of circuits Nr. of compressors Vompressor type
Minichillers 1 1 swing CE.S_COM_APS 6.700,-
Multi-Scroll chillers 1 1-2 scroll CE.S_COM_APS_S 8.200,-
2 2-4 scroll CE.S_COM_APS_S 11.900,-
Screw-Chillers
air- & watercooled
DX-version
1 1 screw CE.S_COM_APS_S 8.900,-
2 2 screw CE.S_COM_APS_M 12.600,-
3 3 screw CE.S_COM_APS_M 18.600,-
4 4 screw CE.S_COM_APS_M 22.300,-
Screw-Chillers
watercooled, fl ooded1 1 screw CE.S_COM_APS_M 10.400,-
1 2 screw CE.S_COM_APS_L 14.900,-
Centrifugal
Chillers1 1 centrifugal CE.S_COM_APS_C 31.200,-
1 2 centrifugal CE.S_COM_APS_C 40.100,-
AHU - - - based on quotation
Additional Services & Materials
On Request On Request
Labour rates
Labour hour service engineer CE.S_LA_HOUR 1.215,-
Labour hour service engineer +50% CE.S_LA_HOUR50 1822,50
Labour hour service engineer +100% CE.S_LA_HOUR100 2.430,-
Labour hour service foreman CE.S_LA_FOR 1.755,-
Labour hour project design CE.S_LA_PRO 1.755,-
Normal working hours without surcharge MON – THU: 08:00-17:00, FRI: 08:00-12:00
50% surcharge MON – FRI: 07:00-08:00 and 17:00-20:00,SAT: 07:00-20:00
100% surcharge Before 07:00 and after 20:00 and on Sundays and holidays
Travel Costs (not including parking, highway tolls etc )
Cost allowance per km CE.S_TR_KM_AL 18,-
Flat travel fee per case CE.S_TR_CASE 1,-
Special travel cost (plane, ferry…) CE.S_TR_SPEC 1,-
Travel zone 1 CE.S_TR_Z1 2.220,-
Travel zone 2 CE.S_TR_Z2 4.160,-
Travel zone 3 CE.S_TR_Z3 6.930,-
Travel zone 4 CE.S_TR_Z4 On Request
Hourly rate for car travel CE.S_TR_HOUR 729,-
Cancellation
Failed travel (customer fault) CE.S_COM_FAILTRAV 50% of planned activity
Training
Full day Training per person per day (minimum 5 participants) CE.S_LA_TRA 6.075,-
ServiceService
Commissioning
To guarantee your Daikin unit effi ciency and long
term performance, Daikin off ers the professional
start-up of your Daikin system by highly
qualifi ed, OEM educated engineers as part of the
commissioning services.
Commissioning through an authorized Partner or by
Daikin itself assures you that your unit is working as
it should and is delivering all the benefi ts of a unique
climate.
Every commissioning is documented as per Daikin
standard and a detailed commissioning report is
provided, detailing all activities done and recording
the functioning of the units.
The prices listed are based on completion of the Pre-Commissioning checklist which covers a range of core activities including the general
conditions at the site, provision of power and the required electrical distribution as well as installation related topics. This ensures that the
service can be provided effi ciently, on time and giving the best results. For the latest edition of the Pre-Commissioning checklist please
visit: www.daikin-ce.com
Applied Systems Price list -
Service
Maintenance is the key element to
ensure the quality, effi ciency and
fl awless operation of any asset.
Our Care agreements are based on
years of experience to ensure you
reap the full benefi ts of having Daikin
Certifi ed engineers maintain your
equipment.
Preventive maintenance and regular
service is a key component in securing
your investment.
Dust, temperature, humidity and
load degrade the reliability and
performance of a HVAC system over
time.
Maintenance
Regular maintenance of a unit or
system ensures that electricity costs
and performance are not jeopardized,
and that the safety features and the
entire system are in line with the latest
standards and regulations.
Regular care safeguards your
investment for the full lifetime of
the Daikin System. Downtime and
failures are avoided, while keeping
operating costs low, as they should be
throughout the entire system lifecycle.
Preventive maintenance plans give you
cost transparency avoiding unexpected
repair costs or degradation of comfort,
quality or production loss.
Daikin Cares contains diff erent levels of maintenance agreements catering to your every need. In addition to these Care packages Daikin off ers a comprehensive set of options you can choose from.
Care is the minimal requirement
to fulfi l current legislation
requirements, and makes sure
your machine is operating in a
correct fashion and according to
parameters.
The Care package includes the
following services:
• Inspections based on predefi ned
activities
• On-site system diagnostic and/or
analysis during service intervention
• Recorded, retrievable service history
of each machine
• Validated Log book
. Care: . Preventive Care: . Extended Care:
Preventive Care keeps the machine
in optimal condition and that the
Warranty is valid for the long run.
In addition to the maintenance
activities included in the Care package,
Preventive Care includes:
• Mechanical inspection (star gate) of
screw compressor
• Capacity regulator overhaul
• Comprehensive oil analysis
• Lifecycle report with status &
measurement report
• Access to Emergency support &
callout
• Technical assistance and repair
service
Extended Care provides maximum
equipment availability at the minimum
Total Cost of Ownership.
In addition to the activities mentioned in
the Preventive care package, Extended
Care includes:
• Oil analysis, refi ll and/or change if
required
• Labor- & travel cost, spare parts for
planned maintenances are included
• Labor- & travel cost, spare parts for
repairs are included
• Remote Predictive Performance
monitoring & Analysis
• Extension of warranty
Options:
Leak test
Remote monitoring
Factory inspection/refurbishment
Specialist support and consultancy
Description Care Preventive Care Extended Care
Maintenance Minichiller On Request On Request On Request
Maintenance Multi-Scroll chiller, 1 circuit, up to 2 compresors On Request On Request On Request
Maintenance Multi-Scroll chiller, 2 circuits, 2-4 compresors On Request On Request On Request
Maintenance Screw-Chiller, 1 circuit, 1 compresor On Request On Request On Request
Maintenance Screw-Chiller, 2 circuits, 2 compresors On Request On Request On Request
Maintenance Screw-Chiller, 3 circuits, 3 compresors On Request On Request On Request
Maintenance Screw-Chiller, 4 circuits, 4 compresors On Request On Request On Request
Maintenance Centrifugal Chiller, 1 circuit, 1 compresor On Request On Request On Request
Maintenance Centrifugal Chiller, 1 circuit, 2 compresors On Request On Request On Request
OptionsDescription
Factory inspection/refurbishment On Request
Specialist support and consultancy On Request
Major Overhaul On Request
Daikin Cares contains diff erent levels of
maintenance agreements catering to your every
need. In addition to these Care packages Daikin
off ers a comprehensive set of options you can choose
from.
Notes
Applied Systems Price list -
Commercial terms and conditions (Last update: March 2017)
Campus 21, Europaring F12 / 402 · A-2345 Brunn am Gebirge, Austria
phone +43 2236 32557, fax +43 2236 32557-900, offi [email protected], www.daikin-ce.com
The Daikin Commercial terms and conditions are also available in the internet at www.daikin-ce.com
These commercial terms and conditions (hereinafter ‘Terms’) shall apply to all of our off ers,
deliveries and services to companies (B2B). Part I shall apply to deliveries of goods. Part II shall
apply to services by our customer service. Any individual agreements deviating from these
Terms shall be valid only if confi rmed by us in writing and duly signed. Any informal statements
are invalid. Any commercial terms and conditions of the ordering party shall not be applicable.
Acceptance of the goods is in any event deemed to constitute acknowledgment of our Terms.
Our customer services to consumers (B2C) shall be subject to separate commercial terms and
conditions. Our commercial terms and conditions can be found at www.daikin-ce.com.
I. COMMERCIAL TERMS AND CONDITIONS FOR DELIVERIES OF GOODS
1. OFFER
Our off ers are without engagement and non-binding. Any representation of models and any
information about dimensions, weights and technical data are non-binding and subject to
production-related and model-related changes. Such changes shall not constitute a defect.
2. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE
1. Orders must be placed in writing (by letter, fax or email or online ordering system). When
Daikin confi rms receipt of the order, this does not constitute an acceptance of the order. We
are deemed to have accepted an order not until after we have explicitly confi rmed acceptance
in writing or actually executed that order. Any arrangement and agreement reached verbally
and by phone must be confi rmed in writing.
2. We reserve the right to rescind the contract even after having accepted an order if information
we have obtained about the customer’s liquidity in the meantime suggests that the customer
will not be able to pay for the entire or for part of the order.
3. Having accepted an order, we also reserve the right to change and improve the deliverable,
e.g. in respect of its type and design, to the extent the customer can be reasonably expected
to accept such changes and improvements in consideration of our interests (e.g. delivery of
an equivalent or more sophisticated device). Such changes and improvements are deemed
approved in advance.
4. The customer’s cancellation or change of an entire or of part of an order requires our written
consent and entitles us to charge the customer - in addition to the services already provided
and costs accrued - a (cancellation) fee equal to 20 % of the order value and at least CZK
250. For certain product groups (e.g. multiple scroll, screw chiller), separate cancellation rules
apply, which can be found at www.daikin-ce.com.
3. PRICES AND TERMS OF PAYMENT
1. Prices are based on the price list, as amended from time to time, which is usually issued once
a year. We reserve the right to change prices also during the year.
2. Prices are understood to be net prices without any taxes, duties or charges in the quoted
currency including packaging, unless otherwise indicated. We will not take back packaging
and packing material.
3. We will not accept any objections to invoices which are received more than two weeks after
receipt of an invoice. Unless otherwise indicated, invoices are due net 30 days from the
invoice date; the payment date is the date on which a payment is received by us. In case of late
payment, we will charge default interest at a rate of 12% p.a. In case of default, we may also
demand all costs related to the collection of our claim, including, without limitation, dunning
and collection charges.
4. If payment by instalments has been agreed, the maturity date will be accelerated if the
customer is in default in respect of only one instalment.
5. We may make deliveries dependent on advance payment.
6. The customer may not withhold or off set payments in reliance on warranty or other claims.
4. DELIVERY TIME
1. Indicated delivery times are non-binding and for reference only, although we endeavour to
meet indicated deadlines. The customer has no right to insist on compliance with a certain
delivery time. As a consequence, delays in delivery will not entail any claims for damages and
do not entitle the customer to rescind the contract. The same holds true if delivery deadlines
are not met due to force majeure, strike or other events outside our control.
2. We will not accept penalty claims asserted by the customer under any circumstances.
3. Partial deliveries are permitted.
4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries
pending payment of the earlier delivery and is not required to pay to the ordering party any
damages in this respect.
5. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE
1. Unless otherwise agreed, deliveries are made CIP (Incoterms 2010) to the named destination
2. In principle, delivery CIP covers only minimum transport insurance. Additional transport
insurance will be purchased only if explicitly requested by customer and subject to a separate
agreement and at the customer’s cost and expense.
3. The customer must immediately check deliverables received by him or directly by his
customers for any transport damage and he must record any damage to the packaging or
the device in the delivery note and shall refuse delivery towards the forwarding agent. If the
customer fi nds out only later that goods are damaged, the customer shall report any such
damage to us immediately, in no case later than three working days after delivery; otherwise,
any insurance claim may expire.
4. If the customer is in delay with acceptance, we - notwithstanding our other rights - may
charge the goods as delivered or may otherwise dispose of them without setting a time
limit. If we otherwise dispose of the goods, the delivery time will recommence on the day we
receive the customer’s written request calling for delivery of the goods.
5. We may charge the customer for any costs incurred due to late acceptance, including, without
limitation, any storage costs, waiting periods, etc..
6. RESERVATION OF TITLE
1. We will retain title to goods delivered pending full payment of all claims arising from our
business relationship with the customer, even if the purchase price for specifi cally designated
claims was paid. If our conditional goods are processed, we will acquire title to the new item
without consideration. If the goods delivered by us are mixed, processed or combined with
other items, the customer hereby assigns to us in proportion of the value of our invoices an
ownership or co-ownership right of the combined or new item, both in respect of the interim
and the fi nal products.
2. The customer may resell goods delivered by us and the items created by processing, mixing
or combining these only in the ordinary course of business. The customer hereby assigns to
us any claims arising from such resale or from any other legal ground toward third parties,
including, ancillary rights, in order to secure our - future - claims that may arise from our
business relationship. The customer must record the assignment of these claims in his books
not later than when the goods are resold.
3. Before having paid the purchase price of an item, the customer may resell that item only if
he simultaneously informs the second buyer (end customer) that the resale proceeds have
previously been assigned.
4. The customer may collect the assigned claims as long as he fulfi ls his payment obligations
towards us according to the terms of the contract. The customer may not otherwise dispose
of the conditional goods (e.g.: transfer of property by way of security, pledging).
5. The customer must immediately inform us of any attachment or other impairment of the
conditional goods and/or the assigned claims and explain to the third party that we have
retained title to those goods. Any related cost will be borne by the customer.
7. WARRANTY
Unless otherwise agreed and excluding any further claims, we warrant for any defects and the
absence of warranted qualities of the goods at the time of delivery as follows:
1. Unless otherwise indicated below, the warranty period is 36 months of the delivery date
(delivery to the forwarding agent). The customer bears the burden of proof that a defect had
existed already at the time of delivery.
2. The customer may assert a warranty claim only if the equipment is both installed and put
into operation by Daikin or a company trained by Daikin according to the Daikin installation
instructions and regularly maintained according to the Daikin service notes and/or operation
instructions.
3. No warranty and/or liability is accepted, unless the customer reports visible defects by giving
written notice within 3 working days of delivery and any other defects are reported without
delay after initial discovery.
4. Unless otherwise agreed, Goods of “Daikin Applied Systems”, which are manufactured on the
basis of a specifi c order, such as chillers, heat pumps, condensing units (equipped with scroll,
screw or centrifugal compressor), fan coil units (FCU) and air handling units / rooftop units
under Daikin brand, generally include a 12-month warranty claim period, provided that the
machine was put into operation by Daikin itself or by a person certifi ed by Daikin. In case of
products designated “J&E Hall International for Daikin” the customer may assert an 18-month
warranty claim. For “Rotex” branded products generally a 24-month warranty period is valid
except for following variations: 10 years for underfl oor heating pipes and system plates, VA-
piping and variosafe oil storage tanks. 5 years for solar panels, variosystem and highcube oil
tanks and variocistern rainwater tanks. 3 years for HPSU heat pump solar unit and hot water
storage tanks HYC, SCS and SC. For “Zanotti” branded products the customer may assert
an 12-month warranty claim from commissioning or 18months from delivery (delivery to the
forwarding agent).
5. In a warranty event, we undertake, at our discretion, to repair the defective goods or
components or to make available faultless goods or components. There are no other
warranty claims whatsoever. Labour cost, travel times, supplies, such as freezing agents and
lubricants, or other costs (e.g. for installation, retrofi tting) will not be reimbursed. Daikin, at
its own discretion, will provide software updates from time to time. Updates may include
error corrections, improvements as well as upgrades. Updates are provided to the customer
in machine-readable and installable form, including installation instructions. The customer is
required to install updates at his own cost and expense within a reasonable period of time.
Any damage caused by a failure to install updates shall be the customer’s sole responsibility,
and Daikin does not accept any liability due to the failure to update a unit.
6. In addition to paragraphs 2 to 3, no warranty and/or liability is accepted for defects that
have been caused by inadequate or improper use or treatment, failure to observe operating
conditions or maintenance instructions, excessive use or inadequate operating materials
or substitute materials or spare parts not provided by Daikin. In addition, no warranty is
accepted for usual wear and tear of wearing parts, including, but not limited to, fi lters, burner
nozzles, carbon brushes of engines, couplings, electrodes, protection anodes, UV probes,
grids, oil or other consumables.
7. Unless we are granted the required time and opportunity to take all necessary warranty
measures, we are released from any warranty claims and damages. If the customer continues
to use defective goods, we warrant and/or are liable only for the original defect. We will not
reimburse any cost of repairs which are carried out without our express prior consent. We
disclaim any liability for the consequences of such repairs.
8. The warranty period for spare parts and other improvements is 6 months of delivery (delivery
to the forwarding agent).
9. If a defect is remedied, the warranty period will not recommence for the replaced or repaired
components.
10. We may refuse to remedy defects as long as the customer is in default with his payment
obligations.
11. If third-party products are delivered and installed, warranty is restricted to assigning the
warranty claims we may assert against the supplier of the third-party product. The customer
may not assert any other warranty claims and does not qualify for any claims for a price
reduction.
8. LIABILITY
We are liable for damage only if we demonstrably acted with intent or gross negligence. We
disclaim any liability for slight negligence. We are particularly not liable for consequential
damage (e.g. idle times due to wrong deliveries) and fi nancial loss, lost profi t, unachieved savings,
loss of interest and any damage suff ered from third-party claims against the customer, unless
the foregoing is attributable to our intent or gross negli¬gence. If damage is attributable to the
defective condition of goods delivered to us, we are liable only to the extent the producer or
upstream supplier is liable to us. Our liability does in any case not exceed the invoice value of the
incriminated goods.
9. GUARANTEE & EXTENDED WARRANTY
1. In addition to warranty, within the warranty period as described in Section 7, we guarantee for
proper functioning and the agreed performance. Daikin’s guarantee covers both materials as
well as working and travel times. The guarantee does not create any claims other than those
for free removal of defects, such as damages. The guarantee shall be valid only if all of the
following requirements have been satisfi ed:
(1) Payment in full by the customer within the agreed performance period;
(2) Professional installation by a licensed business;
(3) Use under the specifi ed conditions (fuel, fi replace, ambient conditions, etc.);
(4) Putting into operation by the Daikin Service or by authorized Daikin service partners.
2. The guarantee shall expire if maintenance work as required by Daikin was not carried out, not
in due time or not by a company authorized by Daikin and if the customer did not comply with
the service intervals as required by Daikin. The burden of proof for proper and timely conduct
of maintenance and cleaning work lies with the customer. The guarantee shall also expire if
the customer uses any accessories not authorized by Daikin or if a company not authorized
by Daikin interferes with and makes changes to the delivered item. Any wearing parts are not
covered by the guarantee.
10. RETURNED GOODS
1. Goods can be returned and exchanged only upon our express and written consent. We accept
returned goods only with a minimum net value of CZK 100.00 per item and a maximum net
value of CZK 50,000.00 per item and only provided that those goods are not damaged, have
not been used, are in original packaging and are fi t for resale. In particular, returns of already
installed units (including chillers) and returns of any made to order units as well as spare parts
are not permitted.
2. The customer shall complete the “Request for Goods Return” form (available at the Daikin
Business Portal https://my.daikin.eu) and send it to us to the fax number or email address
provided by us within 10 calendar days after delivery, otherwise we will not accept the return.
3. Goods must be returned freight paid at the risk of customer to the destination indicated by us.
4. In every case of a return, a maximum of 80% of the net price charged by us to the customer
will be credited. All standard returns will be subject to a restocking / administration charge of
20 % of the net price.
5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance
with paragraph 1. above), we may refuse the returns and have them returned back to the
customer at the customer’s risk and costs. Alternatively, we may charge a higher restocking /
administration fee than the above mentioned 20%.
6. Credit notes of any nature whatsoever will exclusively be off set against future deliveries.
11. INSTALLATION
It is the responsibility of the customer to install and commission the goods and to ensure its
employees, agents and subcontractors or any other persons used by the customer to install and
commission the goods are fully trained to do so and that the terms of any instructions or manuals
provided with the goods are followed.
12. ENVIRONMENT, LICENCES
1. The customer shall be responsible for all costs, charges, and expenses arising from or in
connection with the decommissioning, recovery, recycling and disposal of all or part of the
goods and shall not seek to recover such expenses or contribution from us.
2. The customer is responsible for obtaining and complying with all relevant licenses,
permissions, permits and consents from appropriate regulatory bodies and for complying
with any other lawful authority in connection with the storage, installation, operation, use,
maintenance, repair, transportation, decommissioning, recovery and eventual disposal of the
goods.
3. Where the customer sells all or part of the goods to another party, the customer may enter
into a similar covenant with that party.
13. CONFIDENTIALITY
1. All information and/or advice, whether written or oral, whether in relation to the goods or to
our business, given by us to the customer, shall not be disclosed to any third party without our
prior written consent, save to the extent that such information and/or advice is in the public
domain otherwise than by virtue of a breach of this condition or that the disclosure is required
by law.
2. The customer shall promptly give notice to us of any disclosure required by law and we
may seek an appropriate remedy to prevent such disclosure. The customer undertakes to
fully co-operate with us (at the customer’s own expense) if we reject the validity of such a
requirement.
14. INTELLECTUAL PROPERTY RIGHTS
1. The customer shall have no rights to any intellectual property owned by or licensed to us.
2. The customer shall not allow any trademark or instruction or warning applied to the goods to
be obliterated or obscured.
3. All designs, samples, models, experimental equipment, marketing devices, accessories and
other items relating to the goods or their development or creation shall remain our property,
shall be treated as confi dential and shall not be copied, reproduced or disclosed to any
person without our prior written consent.
15. PERSONAL DATA
1. The customer’s personal data, which we received on the occasion of an order, will be
electronically stored and processed for the purposes of fulfi lling the order, providing goods
and services to the customer, managing the relationship with the customer, for our internal
accounting and processes and for legal or regulatory purposes. For some of these purposes
we may need to share the customer’s data with third parties but we always ensure that the
data are kept confi dential and protected by third parties.
2. The customer agrees that we may ask credit reference agencies and/or credit insurance
companies to run credit searches or checks against the customer in order to assess the
customer’s fi nancial performance and that we may pass on the customer information (name,
address, contact details, name of owner, order details, order history, payment behavior,
customer balance) to Atradius Credit Insurance N.V., Zweigniederlassung Österreich for this
purpose.
3. The customer further agrees that we and other members of our group (as mentioned at
www.daikin.com) may use the customer’s personal data (name, address, contact details,
order details and history) also for our own marketing purposes and contact the customer by
phone, e-mail or SMS or other messaging service about our products and services which may
be of interest to the customer. The customer may revoke his consent at any time.
16. PLACE OF JURISDICTION, APPLICABLE LAW
1. All disputes arising from or in connection with this Agreement shall be exclusively referred to
the courts in Vienna.
2. All contracts concluded by us and all disputes arising in connection with those contracts shall
be governed by and construed in accordance with Austrian law without giving eff ect to its
confl ict of law rules and the UN Sales Convention.
17. SEVERABILITY
Should any term of these commercial terms and conditions or of the contract concluded between
us and the customer be invalid or ineff ective, this shall not aff ect the remaining terms hereof or
thereof. Invalid terms shall be replaced by lawful terms which closest refl ect the parties’ intent.
II. COMMERCIAL TERMS AND CONDITIONS FOR SERVICES
The following conditions shall apply to services provided by our customer service, such as
installation, putting into operation, inspection and troubleshooting, repair and maintenance.
1. SCOPE OF SERVICES
1. The precise scope of service results from our written off er or our written confi rmation of
order. Any additional services not expressly indicated in the off er and/or the confi rmation
of order and provided by us on the customer’s request will be charged separately pursuant
to our applicable price list. The same shall apply if an on-site inspection provides that further
services are required.
2. In case of remote monitoring units, our customer service will take action only if instructed by
the customer.
3. We provide services only for the equipment and unit components delivered and/or produced
by us. The scope of services therefore does not include a test of third-party components, a
leak test of supply pipes created by the customer, a test of electric supply and/or connection
lines, a hydraulic adjustment of the unit. In case of units consisting of third components,
our services do not include an inspection of the entire unit. We will in particular not check
whether the unit is complete and whether its safety devices are consistent with pertinent
regulations and the state of the art.
4. We are not required to check whether information provided and documents (e.g. descriptions
of units, schemes) supplied by the customer are correct.
2. COST ESTIMATES
1. Cost estimates are non-binding and without engagement.
2. If we provided a cost estimate or a package off er, we will obtain prior consent by the customer
in respect of any necessary additional work that can only be identifi ed upon execution, is
required to create operability and exceeds 10% of the sum total.
3. DUTIES TO COOPERATE
1. The customer shall ensure that any cooperation required for the provision of services owed
by us is granted timely and free of charge.
2. The customer shall in particular grant access to the units as required. The customer shall
provide at the customer’s own cost and expense all necessary technical requirements (e.g.
power supply), unless such requirements are to be provided by us under a special agreement.
The customer shall ensure that the respective operating site is suffi ciently lit. If required, the
customer shall provide ladders and scaff olding to enable our employees to easily access the
site safely. The operating site must be easily accessible with a customer service vehicle.
3. The customer shall ensure that remote monitoring units are linked to the telecommunications
network.
4. The customer shall provide all necessary information and documents to enable a smooth
provision of the agreed services. Before the provision of services commences, the customer
shall in particular disclose any change made by the customer or third parties to standard
settings, the control system and other parameters as well as any damage to the unit the
customer is aware of.
5. When a unit is put into operation, the customer shall also provide the requirements referred
to in our related conditions.
6. If the customer does not properly cooperate, we may discontinue our work. In addition, the
customer shall bear all related extra costs, including idle times of our employees who cannot
be used otherwise on short notice, as well as any costs for additional travel time, based on the
applicable prices of our price list.
4. PRICES AND TERMS OF PAYMENT
1. Prices for services are based on the service price list applicable when an order is placed, unless
our written off er provides otherwise.
2. Services will generally be charged based on time actually spent at the agreed hourly rates
plus travel expenses based on fl at fees or time actually spent (km and time).
3. Our regular service times are from Mon-Thu from 8 a.m. to 5 p.m. and on Friday from 7 a.m.
to 12.30 p.m. A 50% surcharge on regular compensation will be charged outside such service
times. A 100% surcharge on compensation will be charged for work provided on Sundays and
public holidays and from 8 p.m. to 7 a.m.
4. Spare parts will be charged on the basis of the price list applicable on the date of replacement
of a unit component. We shall retain title to spare parts pending full payment of an invoice.
5. Invoices will be issued after performance of service.
6. If an order is cancelled by the customer, the customer will be charged 50% of the order value
plus travel expenses, but at least EUR 250.00.
7. Unless otherwise indicated, invoices shall be due and payable without deduction immediately
after invoicing.
8. Otherwise, Section 4 (Prices and Terms of Payment) of our terms and conditions of sale shall
apply mutatis mutandis.
5. WARRANTY
1. We warrant for the diligent, professional provision of services. All services will be provided by
qualifi ed employees.
2. No warranty is accepted, unless the customer gives written notice of visible defects within 3
working days of performance of the service and of any other defects without delay after initial
discovery.
3. Otherwise, Section 8 (Warranty) of our terms and conditions of sale shall apply mutatis
mutandis.
6. MISCELLANEOUS
Unless otherwise provided herein, the provisions of our terms and conditions of sale, especially
those concerning delivery times, reservation of title, liability, environment and licenses, personal
data, jurisdiction and applicable law shall apply to services mutatis mutandis.
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH
campus , Europaring F/, A– Brunn am Gebirge · Tel.: + / / · Fax: + / / - · e-mail: [email protected] · www.daikin-ce.com
Daikin products are distributed by:
The present publication is drawn up by way of information only and does not constitute an offer binding
upon Daikin Europe N.V. / Daikin Central Europe HandelsGmbH. Daikin Europe N.V. / Daikin Central Europe
HandelsGmbH have compiled the content of this publication to the best of their knowledge. No express or
implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content
and the products and services presented therein. Specifications are subject to change without prior notice. Daikin
Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage,
in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is
copyrighted by Daikin Europe N.V.
Daikin Europe N.V. participates in the Eurovent Certification
programme for Liquid Chilling Packages (LCP), Air handling
units (AHU) and Fan coil units (FCU), Check ongoing validity
of certificate online: www.eurovent-certification.com or
using: www.certiflash.com
DACE Applied Systems Pricelist 2017-2018 | Version April 2017
We reserve the right for printing errors and model changes
Order AHU and outdoor in one step
Making life easier for consultants, installers and end-users
through thanks to Daikin’s new fresh air solution
New pre-sized
fresh air solution
Easy selection pre-selected combinations – to cover all fresh air
needs in Europe
The right outdoor unit and the necessary connection
kits to the coil of the AHU are factory mounted and
confi gured.
Total solution – Daikin provides the complete solution
Fast quotation Select as any other unit in Xpress selection software and
show the solution in the report
More details in the dedicated brochure
Download Xpress now with the
new pre-sized combination from
my.daikin.eu
Easy ordering AHU and outdoor unit are automatically selected
in VRV xpress
Easy installation Same pipe diameter from AHU to outdoor unit
Direct integration in
ENERGY EFFICIENCY
2016
Report to performance data
XXX