PreView WorkSight for Waste Rear Loader Page 1 PreView … · 2019. 4. 15. · San Diego, CA 92102...

4
INSTALLATION GUIDE APS-SUPPLY.COM www.aps-supply.com APS USA 610 Gateway Center Way, Suites J & K San Diego, CA 92102 USA P: 1 619 263 4164 F: 1 619 263 6814 APS Australia U48 / 9 Vision Street, Wangara WA 6065 Australia P: 61 (8) 9302 2369 F: 61 (8) 6305 0047 APS: Singapore Colombia Chile Perú Brasil Page 1 PreView Installation Powered By PreView ® WorkSight ® for Waste Rear Loader System Components and Description Model No. Description WS6020R Sensor Assembly, Radar sensor for detection, mounted to the rear of the vehicle. WSZ-ASB Sensor Mounting Bracket, Bracket with 105 degree adjustable angle used for mounting Sensor Assembly. WSW-BKR Sensor Guard Bracket, Bracket is necessary to prevent any damage from occurring to the sensor when the rear loader is loading dumpsters and or utiliz- ing the cable. WSW6102 Display Assembly Operator interface mounted in the vehicle cab. WS-RLBH Body Harness Cable connecting between the rear Sensor and the cab harness. WS-CH Cab Harness Cable connecting to power source and between the body harness and the Display Assembly for Rear Load haulers. Model No. Description Additional Components not shown here: SPV-BKD Display Mounting Bracket Bracket used to mount the Display Assembly in vehicle cab. Display Mounting Hardware Hardware used in mounting the Display Assembly in the vehicle cab. Sensor Mounting Hardware Hardware used in mounting the Sensor Assemblies. User Manual System Operating Manual. WS6020R WSZ-ASB WSW6102 WS-CH WS-RLBH WSW-BKR

Transcript of PreView WorkSight for Waste Rear Loader Page 1 PreView … · 2019. 4. 15. · San Diego, CA 92102...

Page 1: PreView WorkSight for Waste Rear Loader Page 1 PreView … · 2019. 4. 15. · San Diego, CA 92102 USA P: 1 619 263 4164 F: 1 619 263 6814. APS Australia. U48 / 9 Vision Street, Wangara

INSTALLATION GUIDE APS-SUPPLY.COM

www.aps-supply.com

APS USA610 Gateway Center Way, Suites J & K San Diego, CA 92102 USAP: 1 619 263 4164 F: 1 619 263 6814

APS AustraliaU48 / 9 Vision Street, Wangara WA 6065 Australia P: 61 (8) 9302 2369F: 61 (8) 6305 0047

APS: Singapore Colombia Chile Perú Brasil

Page 1 – PreView™ Installation

Document No. 3720610B 1

Powered By PreView® WorkSight® for Waste Rear Loader System Components and Description

Model No. Description

WS6020R Sensor Assembly, Radar sensor for detection, mounted to the rear of the vehicle.

WSZ-ASB Sensor Mounting Bracket, Bracket with 105 degree adjustable angle used for mounting Sensor Assembly.

WSW-BKR Sensor Guard Bracket, Bracket is necessary to prevent any damage from occurring to the sensor when the rear loader is loading dumpsters and or utiliz-ing the cable.

WSW6102 Display Assembly – Operator interface mounted in the vehicle cab.

WS-RLBH Body Harness – Cable connecting between the rear Sensor and the cab harness.

WS-CH Cab Harness – Cable connecting to power source and between the body harness and the Display Assembly for Rear Load haulers.

Model No. Description

Additional Components not shown here:

SPV-BKD Display Mounting Bracket – Bracket used to mount the Display Assembly in vehicle cab.

Display Mounting Hardware – Hardware used in mounting the Display Assembly in the vehicle cab.

Sensor Mounting Hardware – Hardware used in mounting the Sensor Assemblies.

User Manual – System Operating Manual.

WS6020R

WSZ-ASB

WSW6102

WS-CH

WS-RLBH WSW-BKR

10335 W Emerald St Boise, ID 83704

Phone 1.208.323.1000

Page 2: PreView WorkSight for Waste Rear Loader Page 1 PreView … · 2019. 4. 15. · San Diego, CA 92102 USA P: 1 619 263 4164 F: 1 619 263 6814. APS Australia. U48 / 9 Vision Street, Wangara

INSTALLATION GUIDE APS-SUPPLY.COM

www.aps-supply.com

APS USA610 Gateway Center Way, Suites J & K San Diego, CA 92102 USAP: 1 619 263 4164 F: 1 619 263 6814

APS AustraliaU48 / 9 Vision Street, Wangara WA 6065 Australia P: 61 (8) 9302 2369F: 61 (8) 6305 0047

APS: Singapore Colombia Chile Perú Brasil

Page 2 – PreView™ Installation

Document No. 3720610B 2

17° 0°

Powered By:

Connect the PreView® Harness Connect the PreView sen-sor to the body cable (WS-RLBH).

Route cable through channels following exist-ing wiring along path shown.

Continue from this loca-tion with the cab cable (WS-CH) to PreView dis-play and power source.

In the cab, mount and connect the PreView display (WSW6102).

Lastly, connect the red wire to power (+) and the black wire to ground. Rec-ommended power con-nection to reverse circuit allowing system to oper-ate only in reverse mode.

Verify the system is op-erational by viewing the PreView display.

Either bolt or weld the in-cluded brackets toward the center of the truck.

1

1

2

2

3

Body Cable WS-RLBH

4

To Cab

Cab Cable WS-CH

5

3

1

Rear Load Haulers

4

5

Rear Load Haulers typically require mounting of the PreView Sensor with a bracket as shown. Mount the sensor toward the center on the top of the truck using the adjustable bracket. As a starting point, angle the sensor down approximately 17° from vertical. Adjustments to this angle may be made to optimize the detection zone. A Sensor Guard bracket is necessary to prevent any damage to the sensor when the rear loader is loading dumpsters and or utilizing the cable.

PreView® WorkSight® for Waste Rear Loader System Components and Description

10335 W Emerald St Boise, ID 83704

Phone 1.208.323.1000

90°

Page 3: PreView WorkSight for Waste Rear Loader Page 1 PreView … · 2019. 4. 15. · San Diego, CA 92102 USA P: 1 619 263 4164 F: 1 619 263 6814. APS Australia. U48 / 9 Vision Street, Wangara

INSTALLATION GUIDE APS-SUPPLY.COM

www.aps-supply.com

APS USA610 Gateway Center Way, Suites J & K San Diego, CA 92102 USAP: 1 619 263 4164 F: 1 619 263 6814

APS AustraliaU48 / 9 Vision Street, Wangara WA 6065 Australia P: 61 (8) 9302 2369F: 61 (8) 6305 0047

APS: Singapore Colombia Chile Perú Brasil

Page 3 – PreView™ Installation

Document No. 3720610B 3

Display Mounting Location—Inside operator cab, typically either on the dashboard or A-Pillar.

Line of Sight – Display should be mounted in a location where it will be seen through the operators peripheral vision when scanning the left and right mirrors during normal backing operations.

Audible Alert – Display provides both visual LED notification and audible “beep” when an object is detected. Ensure the mounting location will allow the audible alert emitted from the top of the display to be heard by the vehicle operator.

Additional Consideration – When using the PreView System in conjunction with a camera system it is best to mount the PreView Display next to the camera monitor. The audible alert will typi-cally direct the operator to look at the rear view presented on the monitor, allowing a peripheral view of the PreView display as well.

Powered By: PreView® WorkSight® for Waste Rear Loader

System Components and Description 10335 W Emerald St

Boise, ID 83704 Phone 1.208.323.1000

Page 4: PreView WorkSight for Waste Rear Loader Page 1 PreView … · 2019. 4. 15. · San Diego, CA 92102 USA P: 1 619 263 4164 F: 1 619 263 6814. APS Australia. U48 / 9 Vision Street, Wangara

INSTALLATION GUIDE APS-SUPPLY.COM

www.aps-supply.com

APS USA610 Gateway Center Way, Suites J & K San Diego, CA 92102 USAP: 1 619 263 4164 F: 1 619 263 6814

APS AustraliaU48 / 9 Vision Street, Wangara WA 6065 Australia P: 61 (8) 9302 2369F: 61 (8) 6305 0047

APS: Singapore Colombia Chile Perú Brasil

Page 4 – PreView™ Installation

Document No. 3720610B 4

Before testing the system, make sure the sen-sors have a clear field of view. This is most im-portant when testing indoors because the sys-tem may detect walls, posts, etc.

With the parking brake applied, power up the PreView system by turning the vehicles ignition to “on” and placing the transmission in reverse gear. (DO NOT START THE ENGINE UNLESS NECESSARY TO ENGAGE REVERSE GEAR)

Verify the green LED on the display is illumi-nated and the system indicates NO objects are detected. (All detection LED’s are off).

Have an assistant test the detection area of a target by walking in the direc-tion of the arrows in approximately 1 meter increments, starting from direction 1, then 2, and finally 3. Place a traffic cone or some other highly visible marker at the first point of detection as indicated on the monitor in the cab for each arrow direction. Repeat as neces-sary to confirm accurate target detec-tion.

Final detection zone should look similar to the one shown here.

1

2

3

1 2

4

4

APPROXIMATE PATTERN

Powered By: PreView® WorkSight® for Waste Rear Loader

System Components and Description

* Dimensions measuredin Meters

3

10335 W Emerald St Boise, ID 83704

Phone 1.208.323.1000