ETL-GTS-312
EWCTV-312
FAP-HT-250
XCE-062
GENERAL
Application Industrial / Process Aerospace Flight Test & Instrumentation
Automotive Test / Race Car Aerospace Flight Test & Instrumentation
Automotive Test / Race Car Aerospace Flight Test & Instrumentation Blast Testing
Automotive Test / Race Car Flight Test & Instrumentation
Size Standard Threaded Miniature Threaded Less than 1" (25.4mm) Diameter
Cylindrical Probes
Media Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
Any liquid or gas compatible with 15-5 stainless steel and SiO2
All nonconductive, noncorrosive liquids or gases Most conductive liquids and gases
All nonconductive, noncorrosive liquids or gases
Excitation 13 to 32 VDC 18 to 36 VDC
28 ± 4 12 ± 4
10 V 10 V
Temperature -65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C) -65 to +750°F (-55 to +400°C) Up to 900°F (482°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C) -65 to +750°F (-55 to +400°C) Up to 900°F (482°C) Over 1000°F (538°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
Pressure Range 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-25 PSI (0 to 1.7 BAR) 0-50 PSI (0 to 3.5 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-15 PSI (0 to 1.0 BAR) 0-25 PSI (0 to 1.7 BAR) 0-100 PSI (0 to 7 BAR)
0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR)
Operational Mode Absolute Sealed Gage
Absolute Sealed Gage
Absolute Absolute Gage Sealed Gage Differential
Special Products Independent Static/Dynamic Outputs
Water Cooled
Pressure Transducers
![Page 2: Pressure Transducers Comparison](https://reader035.fdocuments.in/reader035/viewer/2022081816/55cf922b550346f57b943f79/html5/thumbnails/2.jpg)
XCE-080
XCE-093
XCE-152
XCEL-062
GENERAL
Application Automotive Test / Race Car Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Size Cylindrical Probes Cylindrical Probes Cylindrical Probes Cylindrical Probes
Media All nonconductive, noncorrosive liquids or gases
All nonconductive, noncorrosive liquids or gases
All nonconductive, noncorrosive liquids or gases
All nonconductive, noncorrosive liquids or gases Most conductive liquids and gases
Excitation 10 V 10 V 10 V 10 V
Temperature -65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
Pressure Range 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR)
0-5 PSI (0 to .35 BAR) 0-15 PSI (0 to 1.0 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-5 PSI (0 to .35 BAR) 0-15 PSI (0 to 1.0 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
Operational Mode Absolute Gage Sealed Gage Differential
Absolute Gage Sealed Gage Differential
Absolute Gage Sealed Gage Differential
Absolute Sealed Gage
Special Products
Pressure Transducers
![Page 3: Pressure Transducers Comparison](https://reader035.fdocuments.in/reader035/viewer/2022081816/55cf922b550346f57b943f79/html5/thumbnails/3.jpg)
XCEL-072
XCEL-100
XCEL-152
XTE-140
GENERAL
Application Automotive Test / Race Car Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Size Cylindrical Probes Cylindrical Probes Cylindrical Probes Miniature Threaded
Media All nonconductive, noncorrosive liquids or gases Most conductive liquids and gases
Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
All nonconductive, noncorrosive liquids or gases
Excitation 10 V 10 V 10 V 10 V
Temperature -65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
Pressure Range 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR)
0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure 0-5 PSI (0 to .35 BAR) 0-15 PSI (0 to 1.0 BAR)
0-5 PSI (0 to .35 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure 0-15 PSI (0 to 1.0 BAR)
0-5 PSI (0 to .35 BAR) 0-15 PSI (0 to 1.0 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR)
Operational Mode Absolute Gage Sealed Gage Differential
Absolute Gage Sealed Gage Differential
Absolute Gage Sealed Gage Differential
Absolute Gage Sealed Gage Differential
Special Products
Pressure Transducers
![Page 4: Pressure Transducers Comparison](https://reader035.fdocuments.in/reader035/viewer/2022081816/55cf922b550346f57b943f79/html5/thumbnails/4.jpg)
XTE-190
XTEH-10L-190
XTEH-7L-190
XTEL-140
GENERAL
Application Automotive Test / Race Car Flight Test & Instrumentation
Aerospace Flight Test & Instrumentation
Aerospace Flight Test & Instrumentation
Automotive Test / Race Car Flight Test & Instrumentation
Size Miniature Threaded Miniature Threaded Miniature Threaded Miniature Threaded
Media All nonconductive, noncorrosive liquids or gases
Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
Excitation 10 V 10 V 10 V 10 V
Temperature -65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C) -65 to +750°F (-55 to +400°C) Up to 900°F (482°C) Over 1000°F (538°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C) -65 to +750°F (-55 to +400°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
Pressure Range 0-5 PSI (0 to .35 BAR) 0-15 PSI (0 to 1.0 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure
0-5 PSI (0 to .35 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) 0-15 PSI (0 to 1.0 BAR)
Operational Mode Absolute Gage Sealed Gage Differential
Absolute Sealed Gage
Absolute Sealed Gage
Absolute Gage Sealed Gage Differential
Special Products
Pressure Transducers
![Page 5: Pressure Transducers Comparison](https://reader035.fdocuments.in/reader035/viewer/2022081816/55cf922b550346f57b943f79/html5/thumbnails/5.jpg)
XTEL-190
XTEL-4-SD-625
XTEL-5-SD-625
GENERAL
Application Automotive Test / Race Car Flight Test & Instrumentation
Industrial / Process Aerospace Flight Test & Instrumentation
Industrial / Process Aerospace Flight Test & Instrumentation
Size Miniature Threaded Less than 1" (25.4mm) Diameter
Less than 1" (25.4mm) Diameter
Media Any liquid or gas compatible with 15-5 stainless steel and SiO2 Most conductive liquids and gases
Others Others
Excitation 10 V 10 V 10 V
Temperature -65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C) -65 to +750°F (-55 to +400°C)
-65 to +250°F (-55 to +120°C) -65 to +350°F (-55 to +175°C) -65 to +450°F (-55 to +235°C) -65 to +525°F (-55 to +273°C) -65 to +750°F (-55 to +400°C)
Pressure Range 0-5 PSI (0 to .35 BAR) 0-100 PSI (0 to 7 BAR) 0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR) High Pressure 0-15 PSI (0 to 1.0 BAR)
0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR)
0-250 PSI (0 to 17 BAR) 0-500 PSI (0 to 35 BAR)
Operational Mode Absolute Gage Sealed Gage Differential
Differential Differential
Special Products Independent Static/Dynamic Outputs
Independent Static/Dynamic Outputs