www.kimray.com A:20.1 Issued 1/13 Current Revision: Change Logo PRESSURE REGULATOR PRESSURE REDUCING Pilot Assembly Motor Valve Stem Assembly Upstream Pressure Downstream Pressure Motor Valve Diaphragm Pressure Adjusting Screw Pilot Spring Pilot Diaphragm Pilot Plug Motor Valve Diaphragm Oil APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure PRESSURE RANGE: Ductile Iron: Upstream: 10 psig to 125 psig Downstream: 5 psig to 125 psig Ductile Iron: Upstream: 10 psig to 300 psig Downstream: 10 psig to 300 psig Steel: Upstream: 10 psig to 300 psig Downstream: 10 psig to 300 psig CAPACITY: Refer to Table of Contents OPERATION: The Pilot Assembly and Motor Valve Stem Assembly (Crosshatched) are the only moving units in the regulator. The PILOT PLUG consists of two stainless balls rigidly con- nected together. Upstream Pressure (Red) is the supply pres- sure to the pilot and is also in constant communication with the top side of the MOTOR VALVE DIAPHRAGM. The area of the MOTOR VALVE DIAPHRAGM is twice the area of the motor valve seat, assuring a positive shut-off. The lower seat for the PILOT PLUG is the Motor Valve Diaphragm Pressure inlet (Red to Yellow). The upper seat for the PILOT PLUG is the pressure vent (Yellow to Atmosphere). The PILOT SPRING loads the upper side of the Pilot Assembly and is opposed on the underneath side by the controlled Downstream Pressure (Blue). Assume the PILOT SPRING is compressed with the ADJUSTING SCREW for a desired Downstream Pressure set- ting. With Downstream Pressure (Blue) too low, the PILOT SPRING forces the Pilot Assembly downward to close the upper seat (Yellow to Atmosphere) and open the lower seat (Red to Yellow). This lets full Upstream Pressure (Red) load the under- neath side of the MOTOR VALVE DIAPHRAGM to balance the pressure on the top side. Upstream Pressure (Red) acting under the motor valve seat, opens the valve. As Downstream Pressure(Blue) increases to the set pressure Pilot Assembly assumes a position in which both seats of the PILOT PLUG are closed. Should Downstream Pressure (Blue) rise above the set pressure, the Pilot Assembly moves upward against the PILOT SPRING to open the pressure vent (Yellow to Atmosphere). Motor Valve Diaphragm Pressure (Yellow) decreases to reposi- tion the Motor Valve Stem Assembly. The intermittent bleed pilot, three-way valve action of the PILOT PLUG against its seat adjusts the Motor Valve Diaphragm Pressure (Yellow), repositioning the Motor Valve stem Assembly to accommodate any rate of flow. The rapid but stable reposition- ing produces a true throttling action.

Transcript of PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change...

Page 1: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:20.1

Issued 1/13Current Revision:Change Logo

PRESSURE REGULATOR

PRESSURE REDUCING

Pilot AssemblyMotor Valve Stem AssemblyUpstream PressureDownstream PressureMotor Valve Diaphragm Pressure

Adjusting Screw

Pilot Spring

Pilot Diaphragm

Pilot Plug

Motor Valve DiaphragmOil

APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

PRESSURE RANGE: Ductile Iron: Upstream: 10 psig to 125 psig Downstream: 5 psig to 125 psig Ductile Iron: Upstream: 10 psig to 300 psig Downstream: 10 psig to 300 psig Steel: Upstream: 10 psig to 300 psig Downstream: 10 psig to 300 psig CAPACITY: Refer to Table of Contents

OPERATION: The Pilot Assembly and Motor Valve Stem Assembly (Crosshatched) are the only moving units in the regulator. The PILOT PLUG consists of two stainless balls rigidly con-nected together. Upstream Pressure (Red) is the supply pres-sure to the pilot and is also in constant communication with the top side of the MOTOR VALVE DIAPHRAGM. The area of the MOTOR VALVE DIAPHRAGM is twice the area of the motor valve seat, assuring a positive shut-off. The lower seat for the PILOT PLUG is the Motor Valve Diaphragm Pressure inlet (Red to Yellow). The upper seat for the PILOT PLUG is the pressure vent (Yellow to Atmosphere). The PILOT SPRING loads the upper side of the Pilot Assembly and is opposed on the underneath side by the controlled Downstream Pressure (Blue). Assume the PILOT SPRING is compressed with the ADJUSTING SCREW for a desired Downstream Pressure set-ting. With Downstream Pressure (Blue) too low, the PILOT SPRING forces the Pilot Assembly downward to close the upper seat (Yellow to Atmosphere) and open the lower seat (Red to Yellow). This lets full Upstream Pressure (Red) load the under-neath side of the MOTOR VALVE DIAPHRAGM to balance the pressure on the top side. Upstream Pressure (Red) acting under the motor valve seat, opens the valve. As Downstream Pressure(Blue) increases to the set pressure Pilot Assembly assumes a position in which both seats of the PILOT PLUG are closed. Should Downstream Pressure (Blue) rise above the set pressure, the Pilot Assembly moves upward against the PILOT SPRING to open the pressure vent (Yellow to Atmosphere). Motor Valve Diaphragm Pressure (Yellow) decreases to reposi-tion the Motor Valve Stem Assembly. The intermittent bleed pilot, three-way valve action of the PILOT PLUG against its seat adjusts the Motor Valve Diaphragm Pressure (Yellow), repositioning the Motor Valve stem Assembly to accommodate any rate of flow. The rapid but stable reposition-ing produces a true throttling action.

Page 2: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:20.4Issued 8/13

Current Revision:Remove Spacer & Change Back Up

AGG 2" FLGD. 227 FGT PR-S 285 285 RAEAGH 3" FLGD. 327 FGT PR-S 285 285 RAFAGI 4" FLGD. 427 FGT PR-S 285 285 RAGAGJ 6" FLGD. 627 FGT PR-S 285 285 RAH

PRESSURE REGULATOR

PRESSURE REDUCINGSTEEL

THRU VALVES AVAILABLE: NOTES:

CAT. SIZE OPER. MAX NO. TYPE REG. NO PRES. W.P. KIT

Dimensions, refer to Table of Contents.

*These parts are recommended spare parts and are stocked as repair kits.

The numbers of a series assigned to a part indicate different line sizes. For example: Stem 138-2", 139-3", 140-4", 141-6".

Page 3: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:140.3

Issued 1/13Current Revision:Change Logo

Gas capacities are based on pressure taken immediately upstream and downstream from the regulator in a wide open position. Critical flow exists across a valve or orifice when the down-stream absolute pressure is approximately half of the upstream absolute pressure. Any decrease in downstream pressure will not increase the flow through the valve. Critical flow conditions on the charts are represented by the MAXIMUM CAPACITY LINE.

GAS CAPACITY CHARTS

200, 285, 300 & 500 psig Maximum W.P. Valves

HOW TO USE CHARTS: Locate UPSTREAM PRESSURE at left of chart. Follow horizontally across to PRESSURE DROP (upstream minus downstream pressure). Read VOLUME directly below. If the horizontal projection of the upstream pres-sure does not intersect the given pressure drop, flow is critical. In this case project UPSTREAM PRESSURE horizontally to the MAXIMUM CAPACITY LINE and read VOLUME directly below.

*For gravity correction multiply above capacities bywhere G equals specific gravity of gas.

.65G;

120

8

10

15

20

30

40

50

60

80

100

110

PRESSURE D

ROP-L

BS P

ER S

Q. IN

.

MAX

IMUM

CAP

ACITY LINE

GAS CAPACITY CHART

140 TO 515

ABSOLUTE psig PRESSURE

2 in. "G" SERIES REGULATORS

VOLUME-MILLIONS CU. FT. PER 24 HRS-.65 SPECIFIC GRAVITY GAS @ 14.4 & 60° *

UPSTR

EAM P

RESSURE-L

BS. PER S

Q. IN

. ABSOLU

TE (Gau

ge +

14.4 p

sig)

140

270

280

290

300

310

320

330

340

350

360

370

380

390

400

410

420

430

440

450

460

470

480

490

500

510515

150

160

170

180

190

200

210

220

230

240

250

260

3.5 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

Page 4: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:140.4Issued 1/13

Current Revision:Change Logo

Gas capacities are based on pressure taken immediately upstream and downstream from the regulator in a wide open position. Critical flow exists across a valve or orifice when the down-stream absolute pressure is approximately half of the upstream absolute pressure. Any decrease in downstream pressure will not increase the flow through the valve. Critical flow conditions on the charts are represented by the MAXIMUM CAPACITY LINE.

GAS CAPACITY CHARTS

220, 285, & 300 psig Maximum W.P. Valves

HOW TO USE CHARTS: Locate UPSTREAM PRESSURE at left of chart. Follow horizontally across to PRESSURE DROP (upstream minus downstream pressure). Read VOLUME directly below. If the horizontal projection of the upstream pres-sure does not intersect the given pressure drop, flow is critical. In this case project UPSTREAM PRESSURE horizontally to the MAXIMUM CAPACITY LINE and read VOLUME directly below.

*For gravity correction multiply above capacities bywhere G equals specific gravity of gas.

.65G;

VOLUME - MILLIONS CU. FT. PER 24 HRS. - .65 SP. GR. GAS AT 14.4 & 60° *

UPSTR

EAM P

RESSURE -

LBS. PER S

Q. IN

. ABSOLU

TE (Gau

ge +

14.4 p

sig)

PRESSURE D

ROP -

LBS. PER S

Q. IN

.

MAX

IMUM

CAP

ACITY LINE

8 10 15

20

30

40

50

60 80

GAS CAPACITY CHART

140 TO 315

ABSOLUTE psig PRESSURE

3 in. "G" SERIES

100

8 9 10 11 12 13 14 15 16 17 18 19 20 25 30

140

150

160

170

180

190

200

210

220

230

240

250

260

270

280

290

300

310315

Page 5: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:140.5

Issued 1/13Current Revision:Change Logo

Gas capacities are based on pressure taken immediately upstream and downstream from the regulator in a wide open position. Critical flow exists across a valve or orifice when the down-stream absolute pressure is approximately half of the upstream absolute pressure. Any decrease in downstream pressure will not increase the flow through the valve. Critical flow conditions on the charts are represented by the MAXIMUM CAPACITY LINE.

GAS CAPACITY CHARTS

220, 285, & 300 psig Maximum W.P. Valves

HOW TO USE CHARTS: Locate UPSTREAM PRESSURE as left of chart. Follow horizontally across to PRESSURE DROP (upstream minus downstream pressure). Read VOLUME directly below. If the horizontal projection of the upstream pres-sure does not intersect the given pressure drop, flow is critical. In this case project UPSTREAM PRESSURE horizontally to the MAXIMUM CAPACITY LINE and read VOLUME directly below.

*For gravity correction multiply above capacities bywhere G equals specific gravity of gas.

.65G;

MAX

IMUM

CAP

ACITY LINE

8 10 15 20

30

40 50 6

0GAS CAPACITY CHART

140 TO 315

ABSOLUTE psig PRESSURE

4 in. "G" SERIES10

0

80

PRESSURE D

ROP -

LBS. PER S

Q. IN

.

VOLUME - MILLIONS CU. FT. PER 24 HRS. - .65 SP. GR. GAS AT 14.4 & 60° *

UPSTR

EAM P

RESSURE -

LBS. PER S

Q. IN

. ABSOLU

TE (Gau

ge +

14.4 p

sig)

14 15 16

140

150

160

170

17 18 19 20 25 30 35 40 45 50 52

180

190

200

210

220

230

240

250

260

270

280

290

300

310315

Page 6: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:140.6Issued 1/13

Current Revision:Change Logo

Gas capacities are based on pressure taken immediately upstream and downstream from the regulator in a wide open position. Critical flow exists across a valve or orifice when the down-stream absolute pressure is approximately half of the upstream absolute pressure. Any decrease in downstream pressure will not increase the flow through the valve. Critical flow conditions on the charts are represented by the MAXIMUM CAPACITY LINE.

GAS CAPACITY CHARTS

220, 285 & 300 psig Maximum W.P. Valves

HOW TO USE CHARTS: Locate UPSTREAM PRESSURE at left of chart. Follow horizontally across to PRESSURE DROP (upstream minus downstream pressure). Read VOLUME directly below. If the horizontal projection of the upstream pres-sure does not intersect the given pressure drop, flow is critical. In this case project UPSTREAM PRESSURE horizontally to the MAXIMUM CAPACITY LINE and read VOLUME directly below.

*For gravity correction multiply above capacities bywhere G equals specific gravity of gas.

.65G;

10

GAS CAPACITY CHART

140 TO 315

ABSOLUTE psig PRESSURE

6 in. "G" SERIES

8

15

20

30

40

50 60

100

80

MAX

IMUM

CAP

ACITY LINE

PRESSURE D

ROP -

LBS. PER S

Q. IN

.

VOLUME - MILLIONS CU. FT. PER 24 HRS. - .65 SP. GR. GAS AT 14.4 & 60° *

UPSTR

EAM P

RESSURE -

LBS. PER S

Q. IN

. ABSOLU

TE (Gau

ge +

14.4 p

sig)

31.5 35 40

140

150

160

170

180

190

200

210

220

230

240

250

260

270

280

290

300

310315

45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 117

Page 7: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:140.7

Issued 1/13Current Revision:Change Logo

LIQUID CAPACITY CHARTS

300 psig Maximum W.P. Valves

PRESSURE DROP

ACROSS VALVEPSIG

VALVE SIZE - INCHES

1 2 3 4

12345

101520304050607080

100125150200250300

7451,0601,3001,5001,7002,3002,9003,3004,1004,7005,3005,8006,2006,7007,5008,4009,300

10,75012,10013,300

1,7602,5003,0503,5003,9005,6006,8007,9009,600

11,10012,40013,60014,70015,70017,60019,70021,50025,00028,00030,900

3,3504,9006,1007,0007,800

11,00013,50015,60019,20022,10024,80027,10029,30031,30033,50039,20040,75047,00052,00057,250

7,80011,00013,50015,60017,50024,70030,20034,90042,70049,30055,20060,50065,40069,80078,20087,50093,000

108,000120,000130,000

CAPACITY-Bbls. Water/Day, Steady Flow

For gravity correction, multiply the above figures byWhere “G” is the specific gravity of the flowing liquid.

1G

Page 8: PRESSURE REDUCINGvsi786.com/kimray/pdfs/A_20.4.pdf · A:140.6 Issued 1/13 Current Revision: Change Logo Gas capacities are based on pressure taken immediately upstream and downstream

www.kimray.comA:140.8Issued 1/13

Current Revision:Change Logo

SCRD

SCRD

FLGD

SCRD

FLGD

GRVD

SCRD

FLGD

FLGD

FLGD

SCRD

1 "

2 "

3 "

250S/FGT

4 "

6 "

4 3/8"

8 3/4"

12"

8 1/2"

9"

12 3/16"

15"15 1/8"

22 1/8"

1 1/8"

2 1/8"

3 1/16"

2 1/8"

4"

3 "

3 3/4"

1 3/4"

3 1/4"

4 1/2"

5 1/2"

7 1/2"

11 1/2"

13"

11 1/2"

11 1/2"

13"14 1/2"

14 1/2"

17"

9 1/8"

10 1/2"

10 1/2"

12 5/16"

15"

22"

14 1/2"

16 1/2"

18 1/2"

20 1/2"

11 5/8"

101/2"

12"

10 1/2"

10 1/2"

12"

13 3/16"

13 3/16"

14 7/8"

14"

15 1/2"

16 11/16"

18 3/8"

3 1/4"

6 1/2"

8 1/2"

6 1/2"

6 1/2"

8 1/2"

10 1/2"

10 1/2"

16"

GAS SERIES REGULATOR

DIMENSIONS

FOR: LOW PRESSURE BACK PRESSURE OUNCES BACK PRESSURE TO VACUUM OUNCES PRESSURE REDUCING OUNCES PRESSURE REDUCING VACUUM VACUUM BACK PRESSURE TO VACUUM

FOR: PRESSURE DIFFERENTIAL PRESSURE REDUCING BACK PRESSURE VACUUM LIQUID BACK PRESSURE

BACK PRESSURE UPSTREAM DIFFERENTIAL PRESSURE PRESSURE REDUCING-BALANCED PRESSURE REDUCING VACUUM

LINESIZE

BODYSTYLE A B C D* FE G H* I

FLANGE DIMENSIONS ARE ANSI 125/150 STANDARD. *Add 7/8" to PRB and USDP Regulators for this dimension.‡Configuration of Back Pressure Valve ia a trademark of Kimray, Inc.

������

��

������

CAST IRON OR DUCTILE STEEL

��

®‡

��

CAST IRON OR DUCTILE STEEL 250 S/FGT-BP-S

�������

������

���

���������

������