Page 1 PrePurchase Building Inspection Report Inspection Date: Wed, 04 Oct 2017 Property Address: Mcilwraith St, Moffat Beach QLD 4551, Australia

Transcript of PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete...

Page 1: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 1

PrePurchase Building Inspection ReportInspection Date: Wed, 04 Oct 2017Property Address: Mcilwraith St, Moffat Beach QLD 4551, Australia

Page 2: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 2

Contents

The parties

Results of inspection - summarySection A

GeneralSection B

AccessibilitySection C

Significant itemsSection D

Additional commentsSection E

Annexures to this reportSection F

Definitions to help you better understand this report

Terms on which this report was prepared

Special conditions or instructions

If you have any queries with this report or require further information, please do not hesitate to contact the person who carried out the inspection.

This Report contains reference to material that is the copyright of Standards Australia. That content is reproduced under agreement with SAI Global to Jim's Building Inspections (Australia).

Original Inspection Date Wed, 04 Oct 2017Modified Date Thu, 05 Oct 2017

Page 3: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 3

The Parties

Name of Client: Mike Kettle

Name of Principal (if applicable):

Job Address: Mcilwraith St, Moffat Beach QLD 4551, Australia

Client's Email Address: [email protected]

Client's Phone Number: 0419 728 807

Consultant: Mark Southern Ph: 0419 739 035Email: [email protected]

QBCC 51251

Company Name: Jim's Building Inspections (Caloundra)

Company Address and Postcode: Little Mountain Qld 4551

Company Email: [email protected]

Company Contact Numbers: 0419 739 035

Special conditions or instructions

A report may be conditional on information provided by the person, agents or employees of the person requesting the report, apparent concealment of possible defects and a range of other factors.

The following apply: Not Applicable

Page 4: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 4

Section A Results of inspection - summary

A summary of your inspection is outlined below; please also refer to the Report.

Found Not Found

Safety Hazard

Major Defect

Minor Defect

Additional specialist inspections: Not Applicable

In summary the building, compared to others of similar age and construction is in good condition with some minor defects found.

Page 5: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 5

Section B General

General description of the property

Building Type: Residential

Number of Storeys: Multi-storey with basement

Main building – floor construction: Part Slab and Part Subfloor, Timber Stumps

Main building – wall construction: Cavity Brick, Fibre Cement Sheets, Timber Framed and Clad, Brick Veneer

Main building – roof construction: Corrugated Iron (e.g. Colourbond)

Other timber building elements: Architraves, Deck, Door Frames, Doors, External Joinery, Floorboards, Internal Joinery, Skirting Boards, Staircase, Veranda Posts, Window Frames

Other building elements: Driveway, Fence - Brick, Fence - Post and Rail Construction, Footpath, Garage, Retaining Walls

Occupancy status: Unoccupied

Furnished: Unfurnished

Strata or company title properties: No

Orientation (to establish the way the property was viewed):

North

Prevailing weather conditions at the time of inspection:

Overcast

Page 6: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 6

Section C Accessibility

Areas Inspected

The following areas were inspected. As documented in your Pre-Inspection Agreement, obstructions and limitations to the accessible areas for inspection are to be expected in any inspection. Refer also to our listing of obstructions and limitations.

- Exterior- Fencing- Interior- Posts- Roof Exterior - First Floor Only- Stumps- Subfloor- Wall Exterior

The inspection excludes areas which are affected by obstructions or where access is limited or unsafe. We do not move obstructions and building defects may not be obvious unless obstructions or unsafe conditions are removed to provide access.

The following areas were inaccessible:

- Locked Rooms.

Any areas which are inaccessible at the time of inspection present a high risk for undetected building defects. The client is strongly advised to make arrangements to access inaccessible areas urgently.

Obstructions and Limitations

Building defects may be concealed by the following obstructions which prevented full inspection:

- Above safe working height- Areas of low roof pitch preventing full inspection- Ceiling cavity inspection was significantly obstructed with more than 75% of the inspectable area inaccessible or obstructed by factors like lack of safe access, insulation and ducting.- Ceiling linings- Fixed Furniture - Built-in Cabinetry- Floor coverings- Wall linings- Webbing of roof trusses - not trafficable

The presence of obstructions increases the risk of undetected defects. The client should make arrangement to remove obstructions where ever possible and re-inspect these areas as a matter of urgency. See also overall risk

Page 7: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 7

rating for undetected defects.

Undetected defect risk

A risk rating is provided to help you understand the degree to which accessibility issues and the presence of obstructions have limited the scope of the inspection.

The risk of undetected defects is: High

When the risk of undetected defects is high we strongly recommend further inspection once access is provided or if the obstruction can be removed. Contact us for further advice.

Page 8: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 8

Section D Significant Items

Safety Hazard

No evidence was found.

Major Defect

No evidence was found.

Minor Defect

Defects 3.01

Building: Main BuildingLocation:Finding: Handrail: BalconyInformation: On the day of inspection it was noted the fixings holding the mid-post handrail on the

Northeast side of the balcony were loose. If left unattended this may lead to a safety hazard if leaned on or struck with force such as a person falling. It is recommended a Builder/Carpenter be consulted to further inspect and rectify.

Page 9: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 9

Section D Significant Items

Defects 3.02

Building: Main BuildingLocation:Finding: Brickwork - Cracking Information: Cracking was identified to the brickwork under the deck in the Northeast corner, and rear

retaining wall. Cracks of this type are likely to have been caused by minor expected movement of building elements, but may also have a structural cause that is more significant. A qualified bricklayer should be contacted immediately to estimate and perform repair and restoration works. Consultation with a structural engineer may be required where structural instability is found to be the underlying cause of the cracking. Always contact a building inspector should cracks widen, lengthen, or become more numerous.

Page 10: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 10

Section D Significant Items

Defects 3.03

Building: Main BuildingLocation:Finding: Posts- Bridging of termite barrierInformation: Several post to the deck area and the landing have not got the required 75mm clearance

(visual zone) to the ground or concrete surfaces. Bridging of termite barriers occurs when termites bridge (usually by building a mud tunnel) a termite barrier or inspection zone or where termites have a passage allowing them to bridge the barrier. Generally this takes the form of finished ground levels external paving or concrete being retrospectively installed above the damp course level the adjacent internal floor level or weep and ventilation holes. Where bridging has occurred full inspection is prevented and termites may enter a property in a concealed or undetectable manner. A carpenter or handyman could remove the soil from around the post or cut the bottom of the post to gain the 75mm required.

Page 11: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 11

Section D Significant Items

Page 12: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 12

Defects 3.04

Building: Main BuildingLocation:Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although fine cracks are quite

noticeable, they are often only considered to be an appearance defect, and usually do not indicate any structural damage. Generally the cause of a hairline crack in existing concrete paving such as driveways and pathways is indicative of the expansion and contraction of the concrete. Such causes are generally due to environmental factors, such as moisture levels, weather conditions, root systems of nearby trees or the soil types on which they are laid. Fine cracks may also be due to poor original installation of the concrete. Factors such as poor compaction of the sub surface and/or inadequate reinforcing of the slab may create cracking and other secondary defects. Monitoring of all cracking should be conducted frequently. Always contact a building inspector should cracks widen, lengthen, or become more numerous.

D4 Further Inspections

We advise that you seek additional specialist inspections from a qualified and, where appropriate, licensed -

Page 13: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 13

- Not Applicable

Jim's Building Inspections can put you in contact with qualified and licensed providers of these and other trades services. Please contact your inspector for recommendations, or visit www.jims.net.

D5 Conclusion - Assessment of overall condition of property

This property when compared to others of similar age and construction is in good condition with some minor defects. The handrail midpost fixings are loose on top balcony. There are cracks to retaining walls under the front deck and rear of the house. Mould was found on ceilings and under stairs. Paint is bubbling on ceilings, walls,at bottom of stairs and the external Northeast corner of the house. There are several doors binding. The plaster is cracking in the internal Northeast corner of the house. Several windows are stiff to slide and have locks missing. The Air Conditioners require plumbing into stormwater. There are drummy tiles in basement area. The posts on East side require 75mm visual barrier. There are some cracks in concrete footpath on the East side of the house. As stated these are minor defects only and would be easily repaired by the relevant trades/contractors.

For further information, advice and clarification please contact Mark Southern on 0419 739 035

Section E Attachments and Further Comments

Page 14: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 14

The following items were noted as - For your information

Noted Item

Building: Main BuildingLocation:Finding: Mould - PresentInformation: Mould was evident in several areas throughout the property. Where evidence of mould

growth was noted, there may be environmental, biological or health issues associated with the report. A specialist inspection by a suitably qualified environmental health inspector may be warranted, where mould is extensive or where any queries regarding air quality spores or other related issues apply. Generally, the client is advised to ensure that the general environment is free of moisture and humidity to aid in the prevention of mould formation and development. Any mould found during the inspection should be cleaned immediately by a cleaning contractor or the homeowner as applicable.

Page 15: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 15

Section E Attachments and Further Comments

Page 16: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 16

Noted Item

Building: Main BuildingLocation:Finding: Painted surface - BubblingInformation: Sections of paint at the bottom of the stairs in basement was found to have bubbled and

deteriorated. Paint bubbling is generally an indication of excessive moisture in the area, that is currently hidden by the painted surface. The presence of excessive moisture can have major implications on associated building elements if left unattended. While only seemingly minor at this stage, the damage cannot be determined due to the paint obstructing any further inspection of the damage. It is highly advised that the affected paint be cleaned to allow a further, more invasive inspection and remedial works carried out.

Page 17: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 17

Section E Attachments and Further Comments

Noted Item

Building: Main BuildingLocation:Finding: Painted surface - BubblingInformation: Sections of paint on the exterior Northeast corner of the top balcony was found to have

bubbled and deteriorated. Paint bubbling is generally an indication of excessive moisture in the area, that is currently hidden by the painted surface. The presence of excessive moisture can have major implications on associated building elements if left unattended. While only seemingly minor at this stage, the damage cannot be determined due to the paint obstructing any further inspection of the damage. It is highly advised that the affected paint be cleaned to allow a further, more invasive inspection by a licensed plumber. Failure to act on this defect may necessitate major works in the future.

Page 18: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 18

Noted Item

Building: Main BuildingLocation:Finding: Door - Binding/jammingInformation: Binding and/or jamming of the Front door and several others was evident during standard

operation. This defect inhibits the functionality of the affected door as well as creating potential for secondary defects to associated building elements. A door that binds to the associated door frame may have several causes, such as poor installation of the door or deteriorated hinges. For minor causes, a qualified carpenter or general handyperson should be appointed to perform minor rectification works at client discretion.

Page 19: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 19

Section E Attachments and Further Comments

Noted Item

Building: Main BuildingLocation:Finding: Cracking - Damage Category 2 - Noticeable (up to 5mm)Information: Noticeable cracks are a common occurrence as a result of many primary defects. Such

causes may include age, general wear and tear, expected building movement, general expansion/contraction of building materials in different weather conditions, and/or minor failings in the installation or application of building materials. Noticeable cracks may result in minor sticking or jamming of associated doors and windows, which require easement. However, noticeable cracks are easily filled and repaired. Monitoring of all cracking should be conducted frequently. Always contact a building inspector should cracks widen, lengthen, or become more numerous. Additionally, your building inspector should also be contacted if associated building elements such as doors and windows become more difficult to operate over time. Relevant tradespeople, such as carpenters, painters and plasterers, should be appointed to perform remedial works, as deemed necessary.

Page 20: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 20

Section E Attachments and Further Comments

Page 21: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 21

Section E Attachments and Further Comments

Noted Item

Building: Main BuildingLocation:Finding: Windows - Stiff to slideInformation: Several windows throughout the property were difficult to operate and their window locks

were damaged or missing at the time of the inspection. Windows provide ventilation to the adjoining area and should be at a fully operational level to ensure user comfort. Restricted function of the window may also pose as a potential safety hazard if required for emergency egress from the building. Generally, factors such as general age of the building element and a lack of maintenance are the usual causes for this type of defect. Replacement of window hardware may be required, as well as minor repairs and cleaning. A registered builder or general handy person will be required to repair the affected windows.

Page 22: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 22

Section E Attachments and Further Comments

Noted Item

Building: Main BuildingLocation:Finding: Air conditioner - Disconnected overflowInformation: The Air Conditioner (A/C) overflow was found to be disconnected from storm water draining

and maycreate excessive moisture in the surrounding area. Such leaking creates an environment which is conducive to an array of defects, including water damage to associated building elements and the attraction of termite or timber pest infestation. It is highly recommended that a licensed plumber be appointed to connect the A/C overflow in order to prevent such an environment from being created. These minor works should be carried out as soon as possible.

Page 23: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 23

Section E Attachments and Further Comments

Noted Item

Building: Main BuildingLocation:Finding: Tiles - DrummyInformation: Drummy tiled areas were identified throughout the basement area at the time of inspection.

The term `drummy` refers to tiles that have become detached from their fixing, despite otherwise being in relatively good condition. Such defects are generally caused by physical or moisture damage to the area. Drummy tiled areas may also be a direct result of poor workmanship during the construction process. Tiled areas may swell and shrink with changes in air humidity if the area has sustained moisture damage. Any exposure to moisture is capable of causing tiled areas to become drummy and/or cracked over a prolonged period of time. Drummy tiled areas generally require removal and replacement of affected tiles, with adequate sealant and grouting. It is advised that a tiling contractor be appointed to perform works as necessary as soon as practicable.

Page 24: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 24

Section E Attachments and Further Comments

Page 25: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 25

Section E Attachments and Further Comments

Noted Item

Building: Main BuildingLocation:Finding: HWS : Corroded Information: The top of the Hot water system has been replaced due to corrosion, however the top rim of

the system is also quite corroded. This appears not to affected the heating capacity of the system at this stage but the system will require replacing in the future. Perhaps a cover over the system may prolong the life of the unit.

Page 26: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 26

Noted Item

Building: Main BuildingLocation:Finding: DECKS, PERGOLAS, BALCONIES, VERANDAHS, AWNINGSInformation: IMPORTANT NOTE: Where any elevated Structure (deck. Balcony, verandah ect) is present,

and this elevated structure is designed to accommodate people, you must have this structure checked by an engineer or other suitably qualified person. You should also arrange annual inspections of the structure by an engineer or other suitably qualified person to ensure any maintenance, that may become necessary, is identified. Care must be taken not to overload the structure. Nothing contained in this report should be taken as an indicator that an assessment has been made, on any elevated structure, as suitable for any specific number of people or purpose. This can only be done by a qualified engineer. For the purpose of this report, the Structure includes elevated decks, verandah, pergolas, balconies, handrails, stairs and children’s play areas.

Noted Item

Building: Main BuildingLocation:Finding: Electrical switchboard - Safety switch installedInformation: A safety switch has been installed to the switchboard. Safety switches are designed to

identify any faults in the electrical circuit throughout the house and switch off the power accordingly. This is a safety measure that is aimed at preventing any personal injury that may result when attempting to operate faulty switches or appliances.

Page 27: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 27

Noted Item

Building: Main BuildingLocation:Finding: Smoke detectors or AlarmsInformation: Reporting on Smoke Detectors or Alarms, including hard wired smoke detection systems

and their legislative requirements, is outside the Scope of this Report. Always ensure sufficient working and suitable smoke detectors are installed prior to occupying any building. Additionally, it is advised that all smoke detectors be tested by the homeowner on a monthly basis.

Page 28: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 28

Definitions to help you better understand this report

Access hole (cover) An opening in flooring or ceiling or other part of a structure (such as service hatch, removable panel) to allow for entry to carry out an inspection, maintenance or repair.

Accessible area An area of the site where sufficient, safe and reasonable access is available to allow inspection within the scope of the inspection.

Appearance defect Fault or deviation from the intended appearance of a building element.

Asbestos Containing Material (ACM)

Asbestos containing material (ACM) means any material or thing that, as part of its design, contains asbestos.

Building element Portion of a building that, by itself or in combination with other such parts, fulfils a characteristic function. NOTE: For example supporting, enclosing, furnishing or servicing building space.

Client The person or other entity for whom the inspection is being carried out.

Defect Fault or deviation from the intended condition of a material, assembly, or component.

Inspection Close and careful scrutiny of a building carried out without dismantling, in order to arrive at a reliable conclusion as to the condition of the building.

Inspector Person or organisation responsible for carrying out the inspection.

Limitation Any factor that prevents full or proper inspection of the building.

Major defect A defect of sufficient magnitude where rectification has to be carried out in order to avoid unsafe conditions, loss of utility or further deterioration of the property.

Minor defect A defect other than a major defect.

Roof space Space between the roof covering and the ceiling immediately below the roof covering.

Serviceability defect Fault or deviation from the intended serviceability performance of a building element.

Significant item An item that is to be reported in accordance with the scope of the inspection.

Site Allotment of land on which a building stands or is to be erected.

Structural defect Fault or deviation from the intended structural performance of a building element.

Structural element Physically distinguishable part of a structure. NOTE: For example wall, columns, beam, connection.

Subfloor space Space between the underside of a suspended floor and the ground.

Page 29: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 29

Terms on which this report was prepared

SERVICE As requested by the Client, the inspection carried out by the Building Inspection Consultant ("the Consultant") was a "Pre-Purchase Building Inspection Report". A Pre-Inspection Agreement was issued for this service and forms part of the service agreement. PURPOSE The purpose of this inspection is to provide advice to the client or other interested party regarding the condition of the property at the time of inspection. SCOPE OF INSPECTION The inspection shall comprise visual assessment of the property and limited assessment of serviceability to identify major defects, urgent and serious safety hazards and to form an opinion regarding the general condition of the property at the time of inspection. An estimate of the costs of rectification of defects is not required in an inspection report. The inspection was limited to Readily Accessible Areas of the Building and Site. The Client shall arrange right of entry, facilitate physical entry and supply necessary information to enable the inspector to undertake the inspection and prepare a report. The Inspector is not responsible for arranging entry to property or parts of the property, where reasonable access or entry is denied those areas are excluded from and do not form part of the inspection. ACCEPTANCE CRITERIA Unless noted in "Special Conditions or Instructions", the building being inspected was compared with a similar building. To the Consultant's knowledge the similar building used for comparison was constructed in accordance with generally accepted practice at the time of construction and which has been maintained such that there is no significant loss of strength and serviceability. Unless noted in "Special Conditions or Instructions", this Report assumes that the existing use of the building will continue. A report may be conditional on the following: (a) Information provided by the person, the employees or agents of the person requesting the report. (b) Apparent concealment of possible defects. (c) Any other factor limiting the preparation of the report. EXTENT OF REPORTING Significant items to be reported are as follows: (a) Major defects. (b) A general impression regarding the extent of minor defects. NOTE: For example, significantly deteriorating exterior paint. (c) Any major defect that is an urgent and serious safety hazard. NOTE: For example, unsafe balustrades or imminent collapse of a structural member. LIMITATIONS The Client acknowledges: 1. That this Report is prepared in accordance with AS 4349.1-2007 but that it is not a Certificate of Compliance of the property within the requirements of any Act, regulation, ordinance, local law or by-law and is not a warranty against problems developing in the future. 2. This Report does not include the inspection and assessment of matters outside the scope of the requested inspection and report. 3. The inspection only covered the Readily Accessible Areas of the Building and Site. The inspection did not include areas which were inaccessible, not readily accessible, and unsafe to access or obstructed at the time of inspection.

Page 30: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 30

Terms on which this report was prepared

Obstructions are defined as any condition or physical limitation which inhibits or prevents inspection and may include - but are not limited to - roofing, fixed ceilings, wall linings, floor coverings, fixtures, fittings, furniture, clothes, stored articles/materials, thermal insulation, sarking, pipe/duct work, builder's debris, vegetation, pavements or earth. 4. This Report has been produced for the use of the Client. The Consultant or their firm or company are not liable for any reliance placed on this report by any third party. EXCLUSIONS This report excludes assessment of: Footings below ground, concealed damp proof course, electrical installations, concealed plumbing, adequacy of roof drainage, gas fittings and fixtures, air-conditioning, automatic garage doors, pools and related equipment, alarm systems, operation of fireplaces and chimneys, flues and solid fuel heaters, alarm and intercom systems, soft floor coverings, appliances, paint coating, health hazards, timber and metal framing size and adequacy, concealed tie downs and bracing, timber pest activity, other mechanical or electrical equipment such as soil conditions, control joints, sustainable development provisions, concealed timber frames, landscaping, rubbish, floor coverings, furniture and accessories, stored items, insulation, environmental matters or lighting and energy efficiency. IMPORTANT SAFETY INFORMATION - SMOKE DETECTORS We cannot comment on smoke detector installation and testing as it is not within the scope of this report and requires specialist inspection services. It is however strongly recommended that all existing detectors in the property be tested prior to occupation and advice be sought as to the suitability of their number, placement and operation. IMPORTANT SAFETY INFORMATION - ASBESTOS We cannot comment on the presence or absence of Asbestos from this building as it is not within the scope of this report and requires specialist inspection services. It is however strongly advised that the presence of Asbestos be presumed until otherwise definitely known. Asbestos containing materials may include sheet type building materials, roofing materials, insulations and linings and more. Especially in buildings that were built or modified pre-1992 further inspection should be undertaken prior to works like renovations, extensions, repairs and maintenance or where any materials which could contain Asbestos become damaged or worn. An Asbestos Inspection And Condition Audit is always advised. IMPORTANT SAFETY INFORMATION - SAFETY GLASS Glazing standards in contemporary or recently constructed buildings are governed by the Building Code of Australia (National Construction Code) and will almost always be constructed using glazing designed to minimise injury if impacted or broken. Glazing in older homes is highly unlikely to be 'Safety Glass' and may cause significant injury if damaged. Exercise care and caution around glass in older homes in particular. This Report only records the observations and conclusions of the Consultant about the readily observable state of the property at the time of inspection. If the Client has any doubt about the purpose, scope and acceptance criteria on which this Report was based please discuss your concerns with the Consultant on receipt of this Report.

Page 31: PrePurchase Building Inspection Report · 2017-10-05 · Finding: Cracking - External Concrete Paving Information: Fine cracks were identified in external concrete paving. Although

Page 31

Terms on which this report was prepared

The Client acknowledges that, unless stated otherwise, the Client as a matter of urgency should implement any recommendation or advice given in this Report. Privacy Policy: We value your personal information, we will ensure it is secure and never share or sell your personal details and contact information. We do however use data collected during inspections for research, commercial, training and educational purposes. For more information please review our Privacy Policy online at www.jimsbuildinginspections.com.au. Compliments, Complaints and Concerns: Your feedback, both positive and negative, can assist us to improve our services. We encourage you to please contact us with any compliments or concerns directly and as soon as you are able. The process for managing customer feedback is documented below: 1. Contact your inspector directly to provide feedback or make any complaint as soon as you are able. 2. If your inspector cannot resolve it or it involves our insurers they will escalate it to their Regional Franchisor (Manager) and / or insurer as applicable. 3. You can also contact their Regional Franchisor (Manager) directly on 131 546 ask to speak to your Inspectors Regional Franchisor (Manager) or email [email protected] Should you have any queries about our terms and conditions, the inclusions and exclusions of this report please contact your Inspector.