Premium treatment starts with premium...

8
by i-Optics Complete your cataract-refractive platform Premium treatment starts with premium diagnosis

Transcript of Premium treatment starts with premium...

Page 1: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

by i-Optics

Complete your cataract-refractive platform

Premium treatment starts withpremium diagnosis

Page 2: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

The premium IOL opportunity

The challenge of determining the exact axis of astigmatism for cataract surgery

Premium IOL market to nearly double in next 5 years There is a huge global unmet need for improved vision correction during cataract surgery. With the total volume of cataract surgeries rising to approximately 30 million per year in 2030, more than 50% of these patients could benefit from astigmatism correction.

The expectations and demands of patients have risen in recent years and the search for perfection becomes critical, especially when it comes to astigmatism correction.Source: Market scope 2013 Comprehensive Report on the Global IOL Market

1.6 million

3 million

Number of patients0

2013

2018

87,5% increase

Cataract surgery volume globally Volume of premium IOL’s implanted globally

22 million

26 million

Cassini 30

A. John Kanellopoulos, MD. Clinical Professor Of Ophthalmology

New York University Medical School

Page 3: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

10

8

6

4

2

0

Stee

p Ax

is re

peat

abili

ty in

deg

rees

Pre-cataract corneas<1.00D

(n=75)

3.03

Keratoconus(n=95)

3.12

Post-LASIK(n=51)

3.45

Axis repeatability in complicated corneas

“Cassini is a better alternative for toric IOL planning and, as such, stands to pave the way for surgeons who have been hesitant to implant these premium lenses”

What top surgeons have to say about Cassini

Douglas Koch, M.D. Baylor College of Medicine, Houston, TX, USA

“Superior in central corneal measurement to Placido and Scheimpflug in case of high irregularity“A. John Kanellopoulos, M.D. Laservision Eye Institute, Athens, GreeceNew York University Medical School, New York, USA

”With Cassini preoperative planning, you can confidently treat your patient’s cataract with Toric IOLs and provide precise astigmatism correction in a single procedure”Jonathan Solomon, M.D. Solomon Eye Associates, Bowie, MD, USA

Getting the Axis right

Source: Kanellopoulos, Asimellis, Friess. CRSToday 2014

Page 4: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

Total Corneal AstigmatismCassini uses patented multi-colored LED point-to-point ray tracing to provide a GPS-like analysis of the cornea along with high-resolution images utilized for surgical guidance. The unique measuring principle enables highly accurate and repeatable measurements of the Total Corneal Astigmatism.

Multi-colored LED point-to-point ray tracing2nd Purkinje point-to-point

ray tracing technology Cassini provides critical information to properly select the power and position of Toric intraocular lenses

Page 5: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

True TechnologyTrue Axis - True MagnitudeTrue Central Coverage - No Central Scotoma

The accurate axis and magnitude of astigmatism plays a vital part in the correct selection and positioning of a toric IOL.

The multi-colored LED coverage is equal across the entire cornea, leaving no space for

central scotoma.

3 mm5 mm7 mm

Cassini 30

A. John Kanellopoulos, MD. Clinical Professor Of Ophthalmology

New York University Medical School

Page 6: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

Increase your ConfidenceAddressing the four most common problems when correcting astigmatism*

Pre-op measurements

Correct toric alignment Accurate marking

Post-op measurement

The accurate post-op Cassini measurements enable the surgeon to optimize the

Surgically Induced Astigmatism (SIA)

Based on highly accurate measurements and marking, the Toric alignment can be

done with high level of confidence

With it’s accuracy and precision, Cassini reduces pre-operative

measurements errors

Along with real time eye-tracking systems such as TrueGuide**, Cassini

can eliminate marking errors

* Berdahl JP, Chu YR, Hill WE. EyeNet, April 2012 Toric IOLs: Four Options for Addressing Residual Astigmatism.**TrueGuide is a trademark of TrueVision 3D Surgical, Inc

Page 7: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

More than 50% of patients eligible for astigmatic correction

Drive more Toric proceduresYour opportunity to expandMost people have astigmatism to some extent. A study of more than 6,000 cataract patients confirms that over 50% of cataract patients have a level of astigmatism that falls within the range correctable by a Toric IOL. That means that a premium IOL is an excellent option for a significant number of your cataract patients.

Source: Hill Distribution Data. Provided courtesy of Dr. Warren Hill.

True data increases your confidence in expanding your premium procedure volume.

17.1%

11.2%

19.1%

14.8%

12.0%

7.8%

5.5%

3.7%

2.9%

1.4%1.3% 0.9%

2.2%

< 0.25 0.25-0.50 0.50-0.75 0.75-1.00 1.00-1.25 1.25-1.50 1.50-1.75 1.75-2.00 2.00-2.25 2.25-2.50 2.50-2.75 2.75-3.00 > 3.00

Perc

enta

ge o

f pat

ient

s

8.7%

47.4%

43.8%

Commonly corrected

Not ideal for astigmatism

correction

Your opportunityto expand

Dioptric intervals in D

17.1%

11.2%

19.1%

14.8%

12.0%

7.8%

5.5%

3.7%

2.9%

1.4%1.3% 0.9%

2.2%

< 0.25 0.25-0.50 0.50-0.75 0.75-1.00 1.00-1.25 1.25-1.50 1.50-1.75 1.75-2.00 2.00-2.25 2.25-2.50 2.50-2.75 2.75-3.00 > 3.00

Perc

enta

ge o

f pat

ient

s

8.7%

47.4%

43.8%

Commonly corrected

Not ideal for astigmatism

correction

Your opportunityto expand

Dioptric intervals in D

Page 8: Premium treatment starts with premium diagnosisiqm-website-prod.s3.amazonaws.com/iqmedical/iqmedical/site/wp-c… · 10 8 6 4 2 0 Steep Axis repeatability in degrees Pre-cataract

For more information: i-Optics USA - [email protected] - +1 888 660 6965i-Optics International - [email protected] - +31 70 3993 112www.i-optics.com

by i-Optics

253 mm/9.96”

528 mm/20.8”

313mm/12.3”

● Multicolor LED Ray-Tracing combined with 2nd Purkinje Imaging Technology ● Axis repeatability within 3 degrees

● Diopter range 4.00D – 171.00D● Display K-values per zone 3 / 5 / 7 / 9 mm

● Instantaneous Auto Capturing● Measurement Quality Factor parameter● Topographic indices: Shape factor, eccentricity, Asphericity, form factor● Keratoconus indices: Surface Asymmetry Index, Surface Regularity Index

● Submicron accuracy due to color LED triangulation technology <0.8µm ● Pupillometry programs - mesopic & photopic ● HD External Ocular Photography ● Topographic maps: Axial, Refractive, Tangential,

snoitarrebA redrO hgiH dna egamI dedroceR ,noitavelE ● Multiple color scale options ● Incorporated Patient management program ● Connectivity: Femto secondlasers, Guidance systems, Toric IOL calculators, USB, Direct print, PDF, JPG, PNG, Excel

Cassini Specifications

True Axis

True Magnitude

True Capture

True Accuracy

True Technology

CA

.BR.

INT.

4.15

Update