by i-Optics
Complete your cataract-refractive platform
Premium treatment starts withpremium diagnosis
The premium IOL opportunity
The challenge of determining the exact axis of astigmatism for cataract surgery
Premium IOL market to nearly double in next 5 years There is a huge global unmet need for improved vision correction during cataract surgery. With the total volume of cataract surgeries rising to approximately 30 million per year in 2030, more than 50% of these patients could benefit from astigmatism correction.
The expectations and demands of patients have risen in recent years and the search for perfection becomes critical, especially when it comes to astigmatism correction.Source: Market scope 2013 Comprehensive Report on the Global IOL Market
1.6 million
3 million
Number of patients0
2013
2018
87,5% increase
Cataract surgery volume globally Volume of premium IOL’s implanted globally
22 million
26 million
Cassini 30
A. John Kanellopoulos, MD. Clinical Professor Of Ophthalmology
New York University Medical School
10
8
6
4
2
0
Stee
p Ax
is re
peat
abili
ty in
deg
rees
Pre-cataract corneas<1.00D
(n=75)
3.03
Keratoconus(n=95)
3.12
Post-LASIK(n=51)
3.45
Axis repeatability in complicated corneas
“Cassini is a better alternative for toric IOL planning and, as such, stands to pave the way for surgeons who have been hesitant to implant these premium lenses”
What top surgeons have to say about Cassini
Douglas Koch, M.D. Baylor College of Medicine, Houston, TX, USA
“Superior in central corneal measurement to Placido and Scheimpflug in case of high irregularity“A. John Kanellopoulos, M.D. Laservision Eye Institute, Athens, GreeceNew York University Medical School, New York, USA
”With Cassini preoperative planning, you can confidently treat your patient’s cataract with Toric IOLs and provide precise astigmatism correction in a single procedure”Jonathan Solomon, M.D. Solomon Eye Associates, Bowie, MD, USA
Getting the Axis right
Source: Kanellopoulos, Asimellis, Friess. CRSToday 2014
Total Corneal AstigmatismCassini uses patented multi-colored LED point-to-point ray tracing to provide a GPS-like analysis of the cornea along with high-resolution images utilized for surgical guidance. The unique measuring principle enables highly accurate and repeatable measurements of the Total Corneal Astigmatism.
Multi-colored LED point-to-point ray tracing2nd Purkinje point-to-point
ray tracing technology Cassini provides critical information to properly select the power and position of Toric intraocular lenses
True TechnologyTrue Axis - True MagnitudeTrue Central Coverage - No Central Scotoma
The accurate axis and magnitude of astigmatism plays a vital part in the correct selection and positioning of a toric IOL.
The multi-colored LED coverage is equal across the entire cornea, leaving no space for
central scotoma.
3 mm5 mm7 mm
Cassini 30
A. John Kanellopoulos, MD. Clinical Professor Of Ophthalmology
New York University Medical School
Increase your ConfidenceAddressing the four most common problems when correcting astigmatism*
Pre-op measurements
Correct toric alignment Accurate marking
Post-op measurement
The accurate post-op Cassini measurements enable the surgeon to optimize the
Surgically Induced Astigmatism (SIA)
Based on highly accurate measurements and marking, the Toric alignment can be
done with high level of confidence
With it’s accuracy and precision, Cassini reduces pre-operative
measurements errors
Along with real time eye-tracking systems such as TrueGuide**, Cassini
can eliminate marking errors
* Berdahl JP, Chu YR, Hill WE. EyeNet, April 2012 Toric IOLs: Four Options for Addressing Residual Astigmatism.**TrueGuide is a trademark of TrueVision 3D Surgical, Inc
More than 50% of patients eligible for astigmatic correction
Drive more Toric proceduresYour opportunity to expandMost people have astigmatism to some extent. A study of more than 6,000 cataract patients confirms that over 50% of cataract patients have a level of astigmatism that falls within the range correctable by a Toric IOL. That means that a premium IOL is an excellent option for a significant number of your cataract patients.
Source: Hill Distribution Data. Provided courtesy of Dr. Warren Hill.
True data increases your confidence in expanding your premium procedure volume.
17.1%
11.2%
19.1%
14.8%
12.0%
7.8%
5.5%
3.7%
2.9%
1.4%1.3% 0.9%
2.2%
< 0.25 0.25-0.50 0.50-0.75 0.75-1.00 1.00-1.25 1.25-1.50 1.50-1.75 1.75-2.00 2.00-2.25 2.25-2.50 2.50-2.75 2.75-3.00 > 3.00
Perc
enta
ge o
f pat
ient
s
8.7%
47.4%
43.8%
Commonly corrected
Not ideal for astigmatism
correction
Your opportunityto expand
Dioptric intervals in D
17.1%
11.2%
19.1%
14.8%
12.0%
7.8%
5.5%
3.7%
2.9%
1.4%1.3% 0.9%
2.2%
< 0.25 0.25-0.50 0.50-0.75 0.75-1.00 1.00-1.25 1.25-1.50 1.50-1.75 1.75-2.00 2.00-2.25 2.25-2.50 2.50-2.75 2.75-3.00 > 3.00
Perc
enta
ge o
f pat
ient
s
8.7%
47.4%
43.8%
Commonly corrected
Not ideal for astigmatism
correction
Your opportunityto expand
Dioptric intervals in D
For more information: i-Optics USA - [email protected] - +1 888 660 6965i-Optics International - [email protected] - +31 70 3993 112www.i-optics.com
by i-Optics
253 mm/9.96”
528 mm/20.8”
313mm/12.3”
● Multicolor LED Ray-Tracing combined with 2nd Purkinje Imaging Technology ● Axis repeatability within 3 degrees
● Diopter range 4.00D – 171.00D● Display K-values per zone 3 / 5 / 7 / 9 mm
● Instantaneous Auto Capturing● Measurement Quality Factor parameter● Topographic indices: Shape factor, eccentricity, Asphericity, form factor● Keratoconus indices: Surface Asymmetry Index, Surface Regularity Index
● Submicron accuracy due to color LED triangulation technology <0.8µm ● Pupillometry programs - mesopic & photopic ● HD External Ocular Photography ● Topographic maps: Axial, Refractive, Tangential,
snoitarrebA redrO hgiH dna egamI dedroceR ,noitavelE ● Multiple color scale options ● Incorporated Patient management program ● Connectivity: Femto secondlasers, Guidance systems, Toric IOL calculators, USB, Direct print, PDF, JPG, PNG, Excel
Cassini Specifications
True Axis
True Magnitude
True Capture
True Accuracy
True Technology
CA
.BR.
INT.
4.15
Update