Preliminary Design Review Solar Thermal Water Heating System Preliminary Design Review Solar Thermal Water Heating System Team #5 Team #5 Team #5 San Diego, California Team #5 San Diego, California Ashley Tyler Tyler Borden Michael Cheney Matthew Murray Heather Hussain Allison Schneider Ashley Tyler Tyler Borden Michael Cheney Matthew Murray Heather Hussain Allison Schneider

Transcript of Preliminary Design Reviewedge.rit.edu/content/C09015/public/PDR.pdf• Siding of the house is Vinyl...

  • Preliminary Design ReviewSolar Thermal Water Heating System

    Preliminary Design ReviewSolar Thermal Water Heating System

    Team #5Team #5Team #5

    San Diego, California

    Team #5

    San Diego, California

    Ashley Tyler

    Tyler Borden

    Michael Cheney

    Matthew Murray

    Heather Hussain

    Allison Schneider

    Ashley Tyler

    Tyler Borden

    Michael Cheney

    Matthew Murray

    Heather Hussain

    Allison Schneider

  • Agenda

    • Introduction

    • Floor Plan Layout

    • House Elevation Drawings

    • Foundation Analysis• Foundation Analysis

    • Roof Truss Analysis

    • Hydronic Subsystem Analysis

    • Heat Transfer Analysis

    • Building Thermal System Analysis

    • Flat Plat Collector Analysis

    • F-Chart Analysis

  • Floor Plan Layout

    • Objectives

    • Support the FPC solar thermal heating system

    • Include the required living spaces.

  • Floor Plan Layout

    �26’ x 44’

  • Floor Plan Layout

    • 9 foot ceilings

    • 26’ x 44’

  • Foundation Analysis

    • Main concerns

    • Secure for house structure including in times of natural

    disaster – Seismic zone 4

    • Basement has both livable and storage qualities• Basement has both livable and storage qualities

    • Foundation protects from the intrusion of environment,

    pests and soil

    • Plastic wrap around total foundation

    • Retains heat

    • Styrofoam insulation

  • Foundation Analysis

    • Other concerns

    • Load bearing wall about 15’ from East or West wall to line

    up with other structures.

    • Footings• Footings

    • Should have a width of 15” and a thickness of 6”

    • At least 12” below surface

  • Foundation Analysis

    • Solution #1- Masonry Foundation

    • Cinderblock build

    • 8 in blocks

    • ≈ $2100 for blocks to create a maximum of a 8’8” • ≈ $2100 for blocks to create a maximum of a 8’8”

    ceiling

    • Rebar reinforcements (#4 to #5) every 48” with extra

    around openings

  • Foundation Analysis

    • Solution #2- Masonry Foundation

    • Cinderblock build

    • 10 in blocks

    • ≈ $2700 for blocks to create a maximum of a 8’8” • ≈ $2700 for blocks to create a maximum of a 8’8”

    ceiling

    • Rebar reinforcements (#4 to #5) every 56” with extra

    around openings

  • Foundation Analysis

    • Solution #3- Poured Foundation• ≈ $10000 for enough concrete to pour to a maximum of

    9’ ceilings

    • Rebar reinforcements (#5 to #6) approximately every 48” • Rebar reinforcements (#5 to #6) approximately every 48” on north side with extra around openings

  • Roof Structure

    • Objectives

    • Support the weight of the roof and FPCs

    • Total weight of roof ~ 6 tons (7lbs/ft2)

    • Total weight of FPCs ~ 600lbs• Total weight of FPCs ~ 600lbs

    • Protect the house from the environment

  • Roof Truss Analysis

    • 3-Tab Shingles• 3-Tab Shingles

    • Light weight

    • 20-30 yrs

    • Architectural Shingles*

    • Heavy duty

    • 30-50 yrs* Used for preliminary analysis

  • Hydronic Subsystem Analysis

    • 28 gpm for 7 FPCs.

    • Preliminary piping layout:

    • Pump and heat exchanger located in the basement.

    • ASTM B88 2.5” Type L Copper Pipe• ASTM B88 2.5” Type L Copper Pipe

    • Head ~ 275ft

  • Building Thermal System AnalysisObjective

    • Prevent heat transfer through the exterior walls of the home

    by decreasing the overall heat transfer coefficient, U-Value

    • Maximize the R-Values by varying the materials and

    thicknesses of wall components

    +

    ∆+

    ∆+

    ∆+∆

    +∆

    +=W

    K

    hk

    x

    k

    x

    k

    x

    k

    xk

    x

    hR

    outsidesiding

    siding

    plywood

    plywood

    stud

    stud

    insulation

    insulation

    gypsum

    gypsum

    insideValue

    2m

    111

    11

    +=K

    W

    RRU

    StudsAtStudsBetweenValue 2

    m

    10.15

    185.0

  • Building Thermal System Analysis

    • Design Constraints

    • Siding of the house is Vinyl

    • Roofing of the house is Asphalt

    • Assumptions• Assumptions

    • Took average thermal conductivity when density varied within

    a material

    • Convert metric units to SI units at termination of calculations

    • 16” studs on Center

    • Sources of heat loss are not accounted for in the analysis

    • Ceiling thermal analysis is independent of structural side

    • Analyze interior to exterior heat transfer only

  • Building Thermal System AnalysisExterior Walls

    ComponentHeat Transfer

    MethodMaterial

    Thermal

    Conductivity

    (W/mK)

    inches millimeters Between

    Studs

    At Studs

    Inside Film Conduction Inside Film 0.12 0.12

    Wallboard Conduction Gypsum

    Board

    0.625 15.875 0.16 0.09921875 0.09921875

    R-Value

    (m2K/W)

    Thickness

    Insulation

    Loose FillConduction

    Celluslosic

    (milled paper

    or wood pulp)

    5.5 139.7

    0.039

    3.34324786 -

    0.045

    Stud Conduction

    Spruce or

    Eastern White

    Pine

    5.5 139.7 0.09 - 1.55222222

    Plywood Conduction Plywood 0.625 15.875 0.15 0.15

    Siding Conduction Foil Backed 0.035 0.889 0.52 0.52

    Outside Film Convection Outside Film 0.03 0.03

    Total Thickness

    (in)

    Total Thickness

    (m)

    R-Value

    (m2K/W)

    R-Value

    (m2K/W)

    6.785 172.339 4.26246661 2.47144097

    U-Value

    (W/m2K)

    U-Value

    (W/m2K)

    0.23460594 0.40462225

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.26010839 0.04580779

  • Building Thermal System AnalysisExterior Walls

    ComponentHeat Transfer

    MethodMaterial

    Thermal

    Conductivity

    (W/mK)

    inches millimeters Between

    Studs

    At Studs

    Inside Film Conduction Inside Film 0.12 0.12

    Wallboard Conduction Gypsum

    Board

    0.625 15.875 0.16 0.09921875 0.09921875

    R-Value

    (m2K/W)

    Thickness

    Stud Conduction

    Spruce or

    Eastern

    White Pine

    5.5 139.7 0.09 - 1.55222222

    Plywood Conduction Plywood 0.625 15.875 0.15 0.15

    Siding Conduction Foil Backed 0.035 0.889 0.52 0.52

    Outside Film Convection Outside Film 0.03 0.03

    Total

    Thickness (in)

    Total

    Thickness (m)

    R-Value

    (m2K/W)

    R-Value

    (m2K/W)

    6.785 172.339 4.41171875 2.47144097

    U-Value

    (W/m2K)

    U-Value

    (W/m2K)

    0.22666903 0.40462225

    5.5 139.7 3.4925 -0.04ConductionGlass Fiber

    Batts

    Insulation

    Blanket and

    Batt

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.25336201 0.04461968

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.26010839 0.04580779

    Loose Fill (previous)

    Blanket and Batt

  • Building Thermal System AnalysisExterior Walls

    ComponentHeat Transfer

    MethodMaterial

    Thermal

    Conductivity

    (W/mK)

    inches millimeters Between

    Studs

    At Studs

    Inside Film Conduction Inside Film 0.12 0.12

    Wallboard Conduction Gypsum

    Board

    0.625 15.875 0.16 0.09921875 0.09921875

    R-Value

    (m2K/W)

    Thickness Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.26010839 0.04580779

    Loose Fill

    Insulation

    Spray AppliedConduction Glass Fiber 5.5 139.7

    0.038

    3.62918354 -

    0.039

    Stud Conduction

    Spruce or

    Eastern White

    Pine

    5.5 139.7 0.09 - 1.55222222

    Plywood Conduction Plywood 0.625 15.875 0.15 0.15

    Siding Conduction Foil Backed 0.035 0.889 0.52 0.52

    Outside Film Convection Outside Film 0.03 0.03

    Total Thickness

    (in)

    Total Thickness

    (m)

    R-Value

    (m2K/W)

    R-Value

    (m2K/W)

    6.785 172.339 4.54840229 2.47144097

    U-Value

    (W/m2K)

    U-Value

    (W/m2K)

    0.21985742 0.40462225

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2

    °F)

    0.24757215 0.04360003

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.25336201 0.04461968

    Blanket and Batt

    Spray Applied

  • Building Thermal System AnalysisExterior Walls

    ComponentHeat Transfer

    MethodMaterial

    Thermal

    Conductivity

    (W/mK)

    inches millimeters Between

    Studs

    At Studs

    Inside Film Conduction Inside Film 0.12 0.12

    Wallboard Conduction Gypsum

    Board

    0.625 15.875 0.16 0.09921875 0.09921875

    R-Value

    (m2K/W)

    ThicknessTotal U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.25336201 0.04461968

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.26010839 0.04580779

    Loose Fill

    Blanket and Batt

    Stud Conduction

    Spruce or

    Eastern

    White Pine

    5.5 139.7 0.09 - 1.55222222

    Plywood Conduction Plywood 0.625 15.875 0.15 0.15

    Siding Conduction Foil Backed 0.035 0.889 0.52 0.52

    Outside Film Convection Outside Film 0.03 0.03

    Total

    Thickness (in)

    Total

    Thickness (m)

    R-Value

    (m2K/W)

    R-Value

    (m2K/W)

    3.285 83.439 3.59290296 2.47144097

    U-Value

    (W/m2K)

    U-Value

    (W/m2K)

    0.27832647 0.40462225

    50.8 2.67368421 -0.019

    Insulation

    Board and

    Slab

    ConductionPolyiso-

    cyanurate2

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.29727084 0.05235248

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2

    °F)

    0.24757215 0.04360003

    Spray Applied

    Board and Slab

  • Building Thermal System AnalysisCeiling Walls

    ComponentHeat Transfer

    MethodMaterial Thickness

    Thermal

    Conductivity

    (W/mK)

    R-Value

    (m2K/W)

    inches millimeters Between Studs At Studs

    Inside Film Conduction Inside Film 0.12 0.12

    Insulation

    Board and SlabConduction

    Polyiso-

    cyanurate5.5 139.7 0.019 7.35263158 -

    Spruce or

    Stud Conduction

    Spruce or

    Eastern White

    Pine

    5.5 139.7 0.09 - 1.55222222

    Plywood Conduction Plywood 0.625 15.875 0.15 0.15

    Roofing Conduction Asphalt 0.035 0.889 0.078 0.078

    Outside Film Convection Outside Film 0.03 0.03

    R-Value

    (m2K/W)

    R-Value

    (m2K/W)

    7.73063158 1.93022222

    U-Value

    (W/m2K)

    U-Value

    (W/m2K)

    0.12935554 0.51807506

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.18766347 0.03304949

  • Building Thermal System AnalysisBasement Walls

    • Foundations Engineer Provided two wall designs

    • Cinderblocks

    • Poured Concert – higher resistance to heat transfer

    ComponentHeat Transfer

    MethodMaterial Type Thickness

    R-Value

    (m2K/W)

    U-Value

    (W/m2K)

    inches millimeters

    Exterior Wall

    Concrete

    Blocks

    ConductionLow-Mass

    Aggregate

    perlite-filled

    cores8 203.2 0.985 1.01522843

    vermiculite-

    filled cores8 203.2 0.81 1.2345679

    molder-EPS-

    filled (beads)

    cores

    8 203.2 0.85 1.17647059

    Exterior Wall

    Poured

    Concrete

    Conduction Concrete

    Sand and

    Gravel or stone

    aggregate

    8 203.2 2.15 0.46511628

  • Building Thermal System AnalysisBasement Walls

    Above Ground

    ComponentHeat Transfer

    MethodMaterial Thickness

    Thermal

    Conductivity

    (W/mK)

    R-Value

    (m2K/W)

    inches millimeters

    Inside Film Conduction Inside Film 0.12

    Wallboard Conduction Gypsum Board 0.625 15.875 0.16 0.09921875

    Exterior Wall

    Concrete BlocksConduction

    Poured

    Concrete

    Sand and

    Gravel or stone

    aggregate

    8 203.2 2.15

    Plywood Conduction Plywood 0.625 15.875 0.15

    Siding Conduction Foil Backed 0.035 0.889 0.52

    Outside Film Convection Outside Film 0.03

    Total R-Value

    (m2K/W)

    3.06921875

    Total U-Value

    (W/m2K)

    Total U-Value

    (BTU/hr ft2 °F)

    0.32581581 0.05737955

  • Building Thermal System AnalysisCalculation of UA Value

    ( ) ( ) ( )( ) ( ) Concrete PouredConcrete Poured

    AppliedSpray ShinglesAsphalt

    BelowBelowAboveAbove

    ExteriorExteriorRoofRoofTotal

    UAUA

    UAUAUA

    +

    ++=

    ( )

    °=

    Fhr

    BTUUA Total 466.8625

    ( ) ( ) ( )

    ( ) ( )

    +

    +

    +

    =

    °F fthr

    BTU 0.4652540

    °F fthr

    BTU0.0574730

    °F fthr

    BTU 0.04362660

    °F fthr

    BTU 0.03301750

    22

    22

    22

    22

    ftft

    ftftUA Total

  • Solar Thermal System AnalysisFlat Plate Collector

    • Average ambient temperature -70.5 degrees Fahrenheit

    • Daily water usage - 80 gallons

    • Tank temperature - 120 degrees Fahrenheit• Tank temperature - 120 degrees Fahrenheit

    • Slope of panel - 32 degrees

    • 1 Glazing coat - Low Iron Tempered Glass

    • Test fluid -Water

    • Absorber material - Copper

    • Fuel type - Electric

  • Solar Thermal System Analysis

    EP-40 EC-32

    Domestic Hot Water System Only

    EP-40 EC-32

  • Solar Thermal System AnalysisDomestic Hot Water System Only

    EC-24EC-24• Best overall - EC-32 with 3 panels

    •Highest Life Cycle Savings•Approx $5,000

    •Total Solar fraction• .983

    •Total weight•343 lbs

    •Total cost of panels• $2609.91

  • Solar Thermal System AnalysisHeating & Water System

    EP-40 EC-32

  • Solar Thermal System AnalysisHeating & Water System

    EC-24 Best overall – EC-32 with 6 panelsEC-24 Best overall – EC-32 with 6 panels•Highest Life Cycle Savings

    •Approx $7,500•Total Solar Fraction

    •.966•Total weight

    •686 lbs•Total cost of panels

    • $5,219.82

  • Questions?

  • References

    • http://www.energysavers.gov/your_home/insulation_airseali

    ng/index.cfm?mytopic=11510

    • http://www.pima.org/ContentPage/wall-insulation.aspx

    • http://rvalue.net/• http://rvalue.net/

    • Fundamentals of Heat Transfer Textbook

    • 2009 Ashrae Handbook - Database