Page 1: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

1|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation

Therapy Option

Nancy Schauer CMD, RT (R) (T)

July 30, 2018

Page 2: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

2|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation Therapy Option

Treatment Planning Treatment Delivery

Planning Contours

Planning CT

Page 3: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

3|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation Therapy Option

Treatment Planning Treatment Delivery

Planning Contours

Planning CT Fan Beam MVCT

Positional Shifts

Page 4: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

4|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation Therapy Option

Treatment Planning Treatment Delivery

Planning Contours

Planning CT Fan Beam MVCT

Positional Shifts

Page 5: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

5|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation Therapy Option

Treatment Planning Treatment Delivery

Planning Contours

Planning CT

• Daily Dose• Cumulative Dose• Dose Metrics• Trending Data

Automatically generates easy to read reports

Fan Beam MVCT

Positional Shifts

Page 6: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

6|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation Therapy OptionEfficiently monitor and adapt plans

Quantitative Images

Integrated Solution

Automated Workflow

Page 7: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

7|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

The Radixact™ Treatment Delivery System’s uniquely designed Fan Beam MVCT enables accurate dose calculations on the daily registration image

Adaptive Radiotherapy with IntegrityQuantitative images

• Fan Beam MVCT provides the integrity of Hounsfield units

• Common imaging and treatment isocenter on ring gantry eliminates need for imaging isocenter QA

• System automatically creates “merged” images

• Daily patient treatment shifts are incorporated in the adaptive software calculations

*Langen, K., Meeks, S., Poole, D. (2005). The Use of Megavoltage CT (MVCT) Images for Dose Recomputation. Med. Phys. Medical Physics, 32(6), 2025. doi:10.1118/1.1998053

Page 8: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

8|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

Integrated PreciseART™ Adaptive Radiation TherapyFully integrated adaptive solution

Integrated delivery and planning systems support the easy, efficient, and accurate monitoring of the effects of anatomical changes and generation of

a modified treatment plan as necessary

• Quantitative MVCT images enable accurate dose calculations using the daily registration image

Reviewing the daily registration of a treatment planning CT and Fan Beam MVCT, we see anatomical changes have taken place

• Target and OAR statistics provide information on anatomical changes that occur over the course of treatment

Page 9: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

9|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

Automated and efficient

Automated features

• Deforms the planning VOIs onto the daily image

• Deforms and accumulates the daily dose on the treatment planning CT

Efficient evaluation

• Generates user-defined reports

• Flags the fraction for review if any delineated structure exceeds user-defined dose or dose-volume tolerances

PreciseART™ Adaptive Radiation Therapy

Review the results of the daily dose (plan re-calculated on the MVCT with deformed contours) relative to the planned dose

The PreciseART™ Option provides the most pertinent information in an easy-to-review format, helping clinicians to determine when a new treatment plan needs to be created

Page 10: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

10|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

Workflow-getting startedPreciseART™ Adaptive Radiation Therapy

Page 11: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

11|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

PreciseART™ Adaptive Radiation TherapyWorkflow - getting started

When a treatment plan is saved as “Deliverable” the patient can be enrolled in the adaptive process.

Patients can also be enrolled retrospectively which will automatically process all completed treatments.

Page 12: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

12|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

The dashboard enables quick review of each enrolled patient’s treatment and status of each delivered fraction

PreciseART™ Adaptive Radiation TherapyWorkflow - dashboard

Patients

Fractions

Green = Fulfilled all user constraintsYellow = Marginal pass Red = Failed 1 or more constraints

Page 13: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

13|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

13

PreciseART™ Adaptive Radiation TherapyAutomated and efficient

Click Workflows to evaluate dose and image registration

Page 14: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

14|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

Customizable daily summary report • Daily dose statistics versus plan, trending data,

volumes, dose (maximum, mean, V95, etc.) and treatment offsets

Daily registration review• Evaluate the results of the daily MVCT registration

Daily dose review • Treatment image with calculated dose and VOIs

warped from the planning image and dose difference versus scaled plan

Cumulative and projected dose reviews• Dose summed back to the planning KVCT with isodose

curves, DVHs, dose statistics and dose difference compared to either scaled plan or projected plan

PreciseART™ Adaptive Radiation TherapyWorkflows - dose and registration review

Page 15: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

15|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

If re-planning is indicated• Create a new “adapted” plan utilizing original

plan data mapped to a new treatment planning CT • Deform original plan contours • Use the plan template from original treatment plan

to help efficiently develop the new adapted plan

Continue the adaptive monitoring workflow process• Software accumulates dose across original

and all new re-plans

PreciseART™ Adaptive Radiation TherapyWorkflows - adapting the plan

Page 16: PreciseART™ Adaptive Radiation Therapy Option...Adaptive Radiotherapy with Integrity. Quantitative images • Automated, offline adaptive dose monitoring • Integrated solution

16|© Accuray and/or its affiliates. All rights reserved. Accuray confidential.

Adaptive Radiotherapy with IntegrityQuantitative images

• Automated, offline adaptive dose monitoring

• Integrated solution in partnership with MIM:‒ Accuray developed the deformation algorithm for warping dose and VOIs‒ MIM Software Inc. provides tools for VOI and dose warping, and

sophisticated reporting

• Fully automated computation of daily results:‒ Dashboard‒ PDF reports‒ Interactive image viewers

Summary