1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable for primary ranges from 5A to 2,400A AC with mA, 0.1A, 1A, 5A, 333mV AC secondary. It improves both intrinsic errors in low current and errors occurred by external vibration and shock with strong durability and minimum tolerance on cutting cross section of core. Main applications are sub metering, power meter, PLC (Programmable Logic Controller), energy automation and etc. JSC-01-250-333mV 250A : 333mV Lot no : 120601 IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV Source Side S1 : White S2 : Black JSC-02-400-333mV 400A : 333mV Lot no : 120601 IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV Source Side S1 : White S2 : Black JSC-03-800-333mV 800A : 333mV Lot no : 120601 IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV Source Side S1 : White S2 : Black 600VAC Max. CAT Additional isolation must be provided if used at higher voltages. P1 P2 600VAC Max. CAT Additional isolation must be provided if used at higher voltages. P1 P2 600VAC Max. CAT Additional isolation must be provided if used at higher voltages. P1 P2 JS24S-250/5A S1 S2 250A : 5A Lot no:120601 IEC60044-1 class 1.0, 1.0VA F=50/60Hz Umax=720V Ui=3kV JS24S-250/1A S1 S2 250A : 1A Lot no:120601 IEC60044-1 class 1.0, 0.2VA F=50/60Hz Umax=720V Ui=3kV

Transcript of PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE...

Page 1: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

1

PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Miniature Split-core AC Current Transformer is suitable for primary ranges from 5A to 2,400A AC with mA, 0.1A, 1A, 5A, 333mV AC secondary.It improves both intrinsic errors in low current and errors occurred by external vibration and shock with strong durability and minimum tolerance on cutting cross section of core. Main applications are sub metering, power meter, PLC (Programmable Logic Controller), energy automation and etc.

JSC-01

-250-3

33mV

250A

: 333

mV

Lot n

o : 12

0601

IEC60

044-1

clas

s 0.5,

0.5V

A

F=50/6

0Hz

Umax=7

20V U

i=3kV

Source Side

S1 :

White

S2 :

Blac

k

E3446

23

JSC-02

-400-3

33mV

400A

: 333

mV

Lot n

o : 12

0601

IEC60

044-1

clas

s 0.5,

0.5V

A

F=50/6

0Hz

Umax=7

20V U

i=3kV

Source Side

S1 :

White

S2 :

Blac

k

E3446

23

JSC-03

-800-3

33mV

800A

: 333

mV

Lot n

o : 12

0601

IEC60

044-1

clas

s 0.5,

0.5V

A

F=50/6

0Hz

Umax=7

20V U

i=3kV

Source Side

S1 :

White

S2 :

Blac

k

E3446

23

600VAC Max. CAT

Additional isolation must be provided

if used at higher voltages.

P1

P2

600VAC Max. CAT

Additional isolation must be provided

if used at higher voltages.

P1

P2

600VAC Max. CAT

Additional isolation must be provided

if used at higher voltages.

P1

P2

JS24S-250/5A

S1 S2

250A : 5A Lot no:120601IEC60044-1 class 1.0, 1.0VA F=50/60Hz Umax=720V Ui=3kV JS24S-250/1A

S1 S2

250A : 1A Lot no:120601IEC60044-1 class 1.0, 0.2VAF=50/60Hz Umax=720V Ui=3kV

Page 2: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

2PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

37

39

41

JC08W-mA Series

JS08W-mA Series

JSXXFL-XXX/XXXmA series

JSXXNL-XXX/XXXmA series

JSXXSL-XXX/XXXmA series

JCXXF-XXXmA series

JCXXFL-XXX-XXXmA series

JC24S-1/2/3 series

JC36S-1/2/3 series

JCXXF-333mV series

JCXXFL-333mV series

JSXXF-XXX-333mV series

JSXXS-XXX-333mV series

JSXXFL-XXX-333mV series

JSXXNL-XXX-333mV series

JSXXSL-XXX-333mV series

JM21X-XXX-333mV series

JSC-XX-XXXX-333mV series

JSC-XXN-XXXX-333mV series

JCXXF-XXX-100mA series

43

45

47

49

51

53

55

57

59

61

63

65

67

69

71

73

75

77

79

81

JCXXN-XXX-100mA series

JSXXF-XXX-100mA series

JSXXS-XXX-100mA series

JSXXFL-XXX-100mA series

JSXXNL-XXX-100mA series

JSXXSL-XXX-100mA series

JM21X-XXX-100mA series

JSC-XX-XXXX-100mA series

JSC-XXN-XXXX-100mA series

JCXXS-XXX-1A series

JSXXS-XXX-1A series

JS18S-XXX-1A series

JM21N-XXX-1A series

JSC-XX-XXXX-1A series

JSXXS-XXX-5A series

JSXXS-XXX-5A series

JSC-XX-XXXX-5A series

JSXXL-XXX-100mA series

JSXXL-XXX-1A series

JSXXL-XXX-5A series

SPLIT-CORE CURRENT TRANSFORMER

CONTENTS

Page 3: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES• Ø5~ Ø8.5mm sensing aperture for non-contact measurement

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation

3 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JC08W-mA Series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Additionally, CTs are deliverable with customized output lead cable.• Silicone rubber reducing sleeves for central positioning of thinner conductors (5.5mm~6.5mm) are optional available.

30A/10mA

0.01~45A (RL=1Ω)

70A

+1±1˚

-0.5 ~ ±1%

3000:1

240±24Ω

SPECIFICATION

ModelJC08W-25

Ø8.5

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

25A/10mA

0.01~42A (RL=1Ω)

70A

+1±1˚

-1.5 ~ ±0.5%

2500:1

200±20Ω

Over-voltage protection circuit is not included, please pay careful attention during installation.

CATⅢ 600V AC / PD2

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

JC08W-30

Ø8.5

(F=50/60Hz)

Page 4: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

4PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

ACCURACY DATA

APPLICATIONS / DIMENSIONS

7.99.5

15.0

16.0

P2 P1

S2

Black White

S1

I

* Unit : mm

1.3

R2

9.5

8

16

Ø 5

Ø 1.6

Ø 6.5

26

9

5.2

10

15

5

R2

Black(S2)

White(S1)

LOAD

CurrentMonitoring

POWER

Output FrequencyOutput Voltage@RL=1ΩLinearity & Phase Angle ErrorModel

JC08W-25

110 100 1000 104 105

10

100

1000Io=25Arms

1 Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)0.1

0.1 1 10 100 1000

1

10

100

1000

1 Ω

Rated Current : 25A/0.0001VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

JC08W-30

110 100 1000 104 105

10

100

1000Io=30Arms

1 Ω0.10.1 1 10 100 1000

1

10

100

1000

1 Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 30A/0.0001VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)Se

con

dar

y Vo

ltag

e(m

V)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

Page 5: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

ModelJS08W-25

Ø8.5

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

25A/10mA

0.01~42A (RL=1Ω)

70A

+1±1˚

-0.5 ~ ±1%

2500:1

200±20Ω

30A/10mA

0.01~45A (RL=1Ω)

70A

+1±1˚

-0.5 ~ ±1%

3000:1

240±24Ω

Over-voltage protection circuit is not included, please pay careful attention during installation

CATⅢ 600V AC / PD2

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

JS08W-30

Ø8.5

(F=50/60Hz)

• Output-lead-wire, secure locking hinge, flat screw clip type make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JS08W-mA Series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Additionally, CTs are deliverable with customized output lead cable.

The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JS series of current transformer is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for discon-nection and reconnection of wiring.

2

3 4

1

OPEN

Flat-headScrewdriver

CLOSE

Flat-headScrewdriver

5 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Page 6: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

6PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

1000 ± 50

AWG#22

Relay cable(common)(attached with CT)

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

Whitewire

Blackwire

3410

50 ±

20

6

8.5 15

Plug housing :SLP-02V

P2 P1

P2

Black(S2)

White(S1)

P1

I

P2 P1

AWG#22

OPTIONLOAD

CurrentMonitoring

S2S1

POWER

Output FrequencyOutput Voltage@RL=1ΩLinearity & Phase Angle ErrorModel

JS08W-25

110 100 1000 104 105

10

100

1000Io=25Arms

1 Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)0.1

0.1 1 10 100 1000

1

10

100

1000

1 Ω

Rated Current : 25A/0.0001VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

JS08W-30

110 100 1000 104 105

10

100

1000Io=30Arms

1 Ω0.10.1 1 10 100 1000

1

10

100

1000

1 Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 30A/0.0001VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)Se

con

dar

y Vo

ltag

e(m

V)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

APPLICATIONS / DIMENSIONS

Page 7: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

ModelJS10FL

Ø10

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

50A/16.6mA

0.1~80A (RL=10Ω)

120A

+1.5±1˚

-1±1%

3000:1

360±25Ω

7.5V0-P

JS16FL

Ø16

100A/33.3mA

0.1~120A (RL=10Ω)

200A

+1.0±1˚

-1±1%

3000:1

280±20Ω

7.5V0-P

JS24FL

Ø24

200A/66.6mA

0.1~200A (RL=10Ω)

300A

+1.0±1˚

-1±1%

3000:1

171±15Ω

7.5V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

(F=50/60Hz)

• Output-lead-wire, secure locking hinge, one-touch structure make easy to install to the existent equip• ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

7 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXFL-XXX/XXXmA series

• If you impact the core contact surface, internal core material could be damaged. • Additionally, CTs are deliverable with customized output lead cable.

JS series of split-core current transformer offers XXXmA at secondary from sensed primary current for metering application. Without using secondary CT inside of meter, it enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation. Especially JS10FL can be installed at secondary of 5A output primary CT to compare meter's accuracy.

Page 8: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

APPLICATIONS / DIMENSIONS

8PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JS10FL

JS24FL

JS16FL

10.1 1 10 100 1000

10

100

1000

1041 0 Ω100Ω1 K Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

1000Io=10Arms

1 0 Ω100Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

110 100 1000 104 105 106

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 50A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 100A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 200A/0.02VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)f(Hz)

Seco

nd

ary

Volt

age(

mV

)

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

Unit : mm

ModelJS10FLJS16FLJS24FL

A40.54565

B2326

37.5

C23.73045

D26.631.633.7

E14.518.821.1

F150±20150±20200±20

Ød101624

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

10FL/16FLAWG#2224FLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

Page 9: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

9 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

ModelJS10NL

Ø10

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

50A/16.6mA

0.1~80A (RL=10Ω)

120A

+1.5±1˚

-1±1%

3000:1

360±25Ω

7.5V0-P

JS16NL

Ø16

100A/33.3mA

0.1~120A (RL=10Ω)

200A

+1.0±1˚

-1±1%

3000:1

280±20Ω

7.5V0-P

JS24NL

Ø24

200A/66.6mA

0.1~200A (RL=10Ω)

300A

+1.0±1˚

-1±1%

3000:1

171±15Ω

7.5V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

(F=50/60Hz)

• Output-lead-wire, secure locking hinge, one-touch structure make easy to install to the existent equip• ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXNL-XXX/XXXmA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Customizing output lead wire

JS series of split-core current transformer offers XXXmA at secondary from sensed primary current for metering application. Without using secondary CT inside of meter, it enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation. Especially JS10NL can be installed at secondary of 5A output primary CT to compare meter's accuracy.

Page 10: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

APPLICATIONS / DIMENSIONS

10PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JS10NL

JS24NL

JS16NL

10.1 1 10 100 1000

10

100

1000

1041 0 Ω100Ω1 K Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

1000Io=10Arms

1 0 Ω100Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

110 100 1000 104 105 106

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 50A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 100A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 200A/0.02VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

Unit : mm

ModelJS10NLJS16NLJS24NL

A40.54565

B2326

37.5

C23.73045

D26.631.633.7

E14.518.821.1

F150±20150±20200±20

Ød101624

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

10NL/16NLAWG#22JS24NLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

Page 11: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

ModelJS24SL

Ø24

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

250A/125mA

0.1~300A (RL=5Ω)

360A

+0.5±0.5˚

±1%

2000:1(Winding : 1980T)

70±5Ω

400A/200mA

0.1~500A (RL=5Ω)

600A

+0.5±0.5˚

±1%

2000:1(Winding : 1970T)

33±4Ω

3.0V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

JS36SL

Ø36

(F=50/60Hz)

• Output-lead-wire, secure locking hinge, one-touch structure make easy to install to the existent equip-ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

11 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXSL-XXX/XXXmA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side. • Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Customizing out put lead wire

JS series of split-core current transformer offers XXXmA at secondary from sensed primary current for metering application. Without using secondary CT inside of meter, it enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

Page 12: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

APPLICATIONS / DIMENSIONS

12PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JS24SL

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)1

0.1 1 10 100 1000

10

100

1000

10

5 Ω

Rated Current : 300A/0.18VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

JS36SL

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

10.1 1 10 100 1000

10

100

1000

10

5 Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 500A/0.31VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)Se

con

dar

y Vo

ltag

e(m

V)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

Unit : mm

ModelJS24SL

A65

B37.5

C45

D33.7

E21.1

Ød24

JS36SL 82.4 48 57.1 40.2 21.1

F200±20200±20 36

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

24SL/36SLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21F-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

Page 13: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

ModelJC10F

Ø10

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

50A/16.6mA

0.1~80A (RL=10Ω)

120A

+1.5±1˚

-1±1%

3000:1

360±25Ω

7.5V0-P

JC16F

Ø16

120A/40mA

0.1~120A (RL=10Ω)

200A

+1.0±1˚

-1±1%

3000:1

280±20Ω

7.5V0-P

JC24F

Ø24

200A/66.6mA

0.1~200A (RL=10Ω)

300A

+1.0±1˚

-1±1%

3000:1

171±15Ω

7.5V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

(F=50/60Hz)

• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JCXXF-XXXmA series

• If you impact the core contact surface, internal core material could be damaged.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire

The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transform-er is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non - interruptible equipment as there is no requirement for disconnection and reconnection of wiring.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

13 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

50A : 16.6mAJD150310

JC10F

S1 S2E344623

50A : 16.6mAJD150310

JC10F

S1 S2E344623

50A : 16.6mAJD150310

JC10F

S1 S2E344623

200A : 66.6mAJD150310

JC24F

S1 S2E344623

120A : 40mAJD150310

JC16F

S1 S2E344623

Page 14: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

APPLICATIONS / DIMENSIONS

14PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JC10F

JC24F

JC16F

10.1 1 10 100 1000

10

100

1000

1041 0 Ω100Ω1 K Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

1000Io=10Arms

1 0 Ω100Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

110 100 1000 104 105 106

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 50A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 100A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 200A/0.02VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)f(Hz)

Seco

nd

ary

Volt

age(

mV

)

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

CONTACTOR

CurrentMonitoring

LOAD

POWER

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

P2 P1

S2 S1

J&D

S2S1

E

D C

B

A

Φd

S2S1

Unit : mm

ModelJC10FJC16FJC24F

A5055

74.5

B384152

C23

29.545

D263134

E14.51922

Ød101624

P2 P1

Page 15: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

ModelJC10FL

Ø10

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

50A/16.6mA

0.1~80A (RL=10Ω)

120A

+1.5±1˚

-1±1%

3000:1

420±30Ω

7.5V0-P

100A/33.3mA

0.1~120A (RL=10Ω)

200A

+1.0±1˚

-1±1%

3000:1

290±25Ω

7.5V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

JC16FL

Ø16

(F=50/60Hz)

• Nylon-spring, secure locking hinge, one-touch structure makes easy to install to the existent equip-ments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified

15 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JCXXFL-XXX-XXXmA series

• If you impact the core contact surface, internal core material could be damaged.• Customizing output lead wire

The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transform-er is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non - interruptible equipment as there is no requirement for disconnection and reconnection of wiring.

50A : 16.6mAJD150310

JC10FL

S1 S2E344623

100A : 33.3mAJD150310

JC16FL

S1 S2E344623

2

3 4

1

P2 P1

Page 16: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

APPLICATIONS / DIMENSIONS

16PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JC10FL

JC16FL

10.1 1 10 100 1000

10

100

1000

1041 0 Ω100Ω1 K Ω

10.1 1 10 100 1000

10

100

1000

101 0 Ω100Ω1 K Ω

110 100 1000 104 105

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

110 100 1000 104 105 106

10

100

1000Io=1Arms

1 0 Ω100Ω1 K Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 50A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 100A/0.002VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

-21 105 20 100 15050 120 200

-1

0

1

2IEC60044-1 P h a s e

Amplitude

CONTACTOR

CurrentMonitoring

LOAD

POWER

S2S1

JC16FL

JC10FL

18.6

0

29.40

16.20

15.7

021

.90

44.6

0

31.60

18.90

5.40

41.2

0

31.70

40.4

0

23.60

10.5

0

10

11

24.70

14.40

26.70

24.4

015

14

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

Page 17: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

JD120601

S1 S2

JC24S-3300A:100mA

SPECIFICATION

ModelJC24S-1

Ø24

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

200A/200mA

0.1~200A (RL=5Ω)

300A

+0.5±0.5°

±1%

1000:1(Winding : 990T)

17±3Ω

3.0V0-P

JC24S-2

Ø24

300A/150mA

0.1~300A (RL=8Ω)

360A

+0.5±0.5°

±1%

2000:1(Winding : 1980T)

70±3Ω

3.0V0-P

JC24S-3

Ø24

300A/100mA

0.1~320A (RL=10Ω)

380A

+0.5±0.5°

±1%

3000:1(Winding : 2970T)

117±10Ω

3.0V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

(F=50/60Hz)

• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JC24S-1/2/3 series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire

The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transformer is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for discon-nection and reconnection of wiring.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

17 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Page 18: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

ACCURACY DATA

APPLICATIONS / DIMENSIONS

18PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JC24S-1

JC24S-3

JC24S-2

10.1 1 10 100 1000

10

100

1000

104

10.1 1 10 100 1000

10

100

1000

10

10.1 1 10 100 1000

10

100

1000

10

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 200A/0.2VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 300A/0.18VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 300A/10.1VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)f(Hz)

Seco

nd

ary

Volt

age(

mV

)

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

5 Ω

8 Ω

10Ω

LOAD

CONTACTOR

CurrentMonitoring

S1

S2

POWER

74.5

52

45

S1 S2

24

2422

34

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

P2 P1

Page 19: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

ModelJC36S-1

Ø36

Current Ratio

Current Range

Max Continuous Current

Nominal Phase Angle Error

Nominal Linearity Error

Turns Ratio

DCR

Protection Level

Insulation Category

Operating Condition

Storage Condition

300A/300mA

0.1~300A (RL=5Ω)

400A

+0.5±0.5˚

±1%

1000:1(Winding : 990T)

7±2Ω

3.0V0-P

JC36S-2

Ø36

500A/250mA

0.1~500A (RL=5Ω)

600A

+0.5±0.5˚

±1%

2000:1(Winding : 1970T)

33±4Ω

3.0V0-P

JC36S-3

Ø36

600A/200mA

0.1~620A (RL=2Ω)

650A

+0.5±0.5˚

±1%

3000:1(Winding : 2955T)

58±7Ω

3.0V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

(F=50/60Hz)

19 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 -1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JC36S-1/2/3 series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire

The split-core current transformer design is used for energy efficiency monitoring and automation applications. This includes sub-metering cost allocation, dynamic energy consumption and peak load analysis. The JC series of current transformer is simple to use, compact split-core design which is easily installed for metering applications. This is ideal for distributed measurement systems and can be retro-fitted into existing installations and non-interruptible equipment as there is no requirement for discon-nection and reconnection of wiring.

JD120601

S1 S2

JC36S-3600A:200mA

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

Page 20: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

20PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

ACCURACY DATA

APPLICATIONS / DIMENSIONS

Output FrequencyOutput VoltageLinearity & Phase Angle ErrorModel

JC36S-1

JC36S-3

JC36S-2

10.1 1 10 100 1000

10

100

1000

104

10.1 1 10 100 1000

10

100

1000

10

10.1 1 10 100 1000

10

100

1000

10

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

110 100 1000 104 105

10

100

1000Io=10Arms

1 0 Ω100Ω

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Primary Current@50Hz(I)

Seco

nd

ary

Volt

age(

mV

)

Rated Current : 300A/0.15VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 500A/0.31VA@50Hz

F(I)

[%]&

f[˚]

@25

C

Rated Current : 600A/0.08VA@50Hz

F(I)

[%]&

f[˚]

@25

C

f(Hz)

Seco

nd

ary

Volt

age(

mV

)f(Hz)

Seco

nd

ary

Volt

age(

mV

)

f(Hz)

Seco

nd

ary

Volt

age(

mV

)

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

-21 105 20 100 15050 120 200

-1

0

1

2

IEC60044-1 P h a s eAmplitude

5 Ω

5 Ω

2 Ω

LOAD

CONTACTOR

CurrentMonitoringS1

S

2

POWER

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

91

62

57

S1 S2

36

36

2240.5

P2 P1

Page 21: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

21 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

ModelJC10F-333(xxx)

Ø10

Amperage Range

Output Voltage

Nominal Phase Angle Error

Nominal Linearity Error

Protection Level

Insulation Category

Operating Condition

Storage Condition

5, 10, 20, 2530, 50, 75

+1.5 ± 1˚

-1 ± 1%

JC16F-333(xxx)

Ø16

70, 100

+1.0 ± 1˚

-1 ± 1%

2.2V0-P

JC24F-333(xxx)

Ø24

5, 10, 30, 50, 70100, 150, 200

+1.0 ± 1˚

-1 ± 1%

JC36S-333(xxx)

Ø36

300, 400,500, 600

+0.5 ± 0.5˚

± 1%

3.0V0-PCATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

333mV

(F=50/60Hz)

• High accuracy : 1% from 10% to 120% of rated current• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010-1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JCXXF-333mV series

• If you impact the core contact surface, internal core material could be damaged.(Ø10, Ø16, Ø24 type)• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.(Ø36 type)• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing output lead wire

JC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

vac

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

50A : 333mVJD150310

JC10F-333

S1 S2E344623

50A : 333mVJD150310

JC10F-333

S1 S2E344623

50A : 333mVJD150310

JC10F-333

S1 S2E344623

100A : 333mVJD150310

JC16F-333

S1 S2E344623

200A : 333mVJD150310

JC24F-333

S1 S2E344623

400A : 333mVJD150310

JC36S-333

S1 S2E344623

Page 22: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

22PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

OUTPUT VOLTAGE DATA

APPLICATIONS / DIMENSIONS

JC10F-333

5 10 20 25 30 500 75

Thru-hole Current Io (Arms 50/60Hz)

400mV

333mV

Out

put V

olta

ge E

o (V

ac)

Limiter

Rated Output

JC16F-333

400mV

333mV

Out

put V

olta

ge E

o (V

ac)

1000

Thru-hole Current Io (Arms 50/60Hz)

Limiter

Rated Output

70

JC24F-333

400mV

333mV

Out

put V

olta

ge E

o (V

ac)

10050 700 20015010 305

Thru-hole Current Io (Arms 50/60Hz)

Limiter

Rated Output

JC36S-333

400mV

333mV

Out

put V

olta

ge E

o (V

ac)

4000

Thru-hole Current Io (Arms 50/60Hz)

Limiter

Rated Output

300 500 600

P2 P1

CONTACTOR

CurrentMonitoring

LOAD

POWER

S2 S1

J&D

S2S1

E

D C

B

A

Unit : mm

ModelJC10F-333JC16F-333JC24F-333JC36S-333

A5055

74.591

B38415262

C23

29.54557

D263134

40.5

E14.5192222

Ød10162436

M3 Screw M3 Screw

P2 P1

L K

S2

S1

Φd

Page 23: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

23 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

ModelJC10FL-333(xxx)

Ø10

Amperage Range

Output Voltage

Nominal Phase Angle Error

Nominal Linearity Error

Protection Level

Insulation Category

Operating Condition

Storage Condition

5, 10, 20, 2530, 50, 75

+1.5 ± 1˚

-1 ± 1%

JC16FL-333(xxx)

Ø16

70, 100

+1.0 ± 1˚

-1 ± 1%

2.2V0-P

CATⅢ

-20˚C~+50˚C, ≤85%RH, No condensation, In-house & Any direction installable

-30˚C~+90˚C, ≤85%RH, No condensation

333mV

(F=50/60Hz)

• High accuracy : 1% from 10% to 120% of rated current• Nylon-spring, output-terminal, secure locking hinge, one-touch structure makes easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010-1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

SPLIT-CORE CURRENT TRANSFORMER

JCXXFL-333mV series

• If you impact the core contact surface, internal core material could be damaged.• Customizing output lead wire

JC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact meter design and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

vac

120A : 40mAJD150310

JC16FL

S1 S2E344623

5A : 333mVJD150310

JC10FL-333

S1 S2E344623

70A : 333mVJD150310

JC16FL-333

S1 S2E344623

HOW TO USE 2

3 4

1

P2 P1

Page 24: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

24PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

OUTPUT VOLTAGE DATA

APPLICATIONS / DIMENSIONS

JC10FL-333

5 10 20 25 30 500 75

Thru-hole Current Io (Arms 50/60Hz)

400mV

333mV

Out

put V

olta

ge E

o (V

ac)

Limiter

Rated Output

JC16FL-333

400mV

333mV

Out

put V

olta

ge E

o (V

ac)

1000

Thru-hole Current Io (Arms 50/60Hz)

Limiter

Rated Output

70

CONTACTOR

CurrentMonitoring

LOAD

POWER

S2S1

JC16FL-333

JC10FL-33318

.60

29.40

16.20

15.7

021

.90

44.6

0

31.60

18.90

5.40

41.2

0

31.70

40.4

0

23.60

10.5

0

10

11

24.70

14.40

26.70

24.4

015

14

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

Page 25: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXF-XXX-333mV series

• If you impact the core surface, internal core material could be damaged.• Customizing output lead wire

JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

25 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

vac

JS24F-200/333mV

S1 S2

200A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VA F=50/60Hz Umax=720V Ui=3kV

150A : 333mV Lot no:120601IEC60044-1 class 1.0, 0.033VAF=50/60Hz Umax=720V Ui=3kV

JS17F-150/333mV

S1 S2

2 3

4 5 6

1

Terminalcover

OPEN

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

P2 P1

METER

Page 26: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

26PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Dimensions

35.8

26.2

P2 P1

64.1

41.1

33.1

S1 S2

17

17

Dimensions

74.5

47

45

S1 S2

24

24

21.1

33.7

P2 P1

M3 Screw M3 Screw

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S1S2

P1P2

BipolarDirectionalZenor Diode

S1S2

P1P2

How to Order / Model Reference

eg - / J S 1 7 F 00 0 333 mV

Model J S 1 7 F

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 2 4 F 00 0 333 mV

Model J S 2 4 F

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Current Transformer Ratios

50 0.05 050100 0.05 100125 0.05 125150 0.05 150

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Current Transformer Ratios

200 0.05 200

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Page 27: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

27 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20°C to 55°C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXS-XXX-333mV series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

vac

2 3

4 5 6

1

Terminalcover

OPEN

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

P2 P1

METER

JS24S-250/333mV

S1 S2

250A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VA F=50/60Hz Umax=720V Ui=3kV

JS36S-500/333mV

S1 S2

500A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VA F=50/60Hz Umax=720V Ui=3kV

200A : 333mV Lot no:120601IEC60044-1 class 0.5S, 0.033VAF=50/60Hz Umax=720V Ui=3kV

JS17S-200/333mV

S1 S2

Page 28: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

28PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Dimensions

M3 Screw M3 Screw

Dimensions

M3 Screw M3 Screw

Dimensions

M3 Screw M3 Screw

How to Order / Model Reference

eg - / J S 1 7 S 00 0 333 mV

Model J S 1 7 S

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 2 4 S 00 0 333 mV

Model J S 2 4 S

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 3 6 S 00 0 333 mV

Model J S 3 6 S

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

S1S2

P1P2

BipolarDirectionalZenor Diode

S1S2

P1P2

BipolarDirectionalZenor Diode

S1S2

P1P2

35.8

26.2

P2 P1

64.1

41.1

33.1

S1 S2

17

17

91.4

57

57.1

S1 S2

36

36

21.140.2

P2 P1

74.5

47

45

S1 S2

24

24

21.1

33.7

P2 P1

Current Transformer Ratios

200 0.05 200

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Current Transformer Ratios

250 0.05 250300 0.05 300

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

300 0.05 300400 0.05 400500 0.05 500600 0.05 600

Page 29: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

29 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXFL-XXX-333mV series

• If you impact the core surface, internal core material could be damaged.• Customizing output lead wire

JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20°C to 55°C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

vac

Page 30: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

APPLICATIONS / DIMENSIONS

30PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg 1 - / SJ 1 0 F L 00 0 333 mV

Model J S 1 0 F L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 1 6 F L 00 0 333 mV

Model J S 1 6 F L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 2 4 F L 00 0 333 mV

Model J S 2 4 F L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Current Transformer Ratios

5 0.05 00510 0.05 01020 0.05 02025 0.05 02530 0.05 03050 0.05 05075 0.05 075

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Current Transformer Ratios

70 0.05 070100 0.05 100

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

5 0.05 00510 0.05 01030 0.05 03050 0.05 05070 0.05 070

100 0.05 100150 0.05 150200 0.05 200

Unit : mm

ModelJS10FLJS16FLJS24FL

A40.54565

B2326

37.5

C23.73045

D26.631.633.7

E14.518.821.1

F150±20150±20200±20

Ød101624

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

10FL/16FLAWG#2224FLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

Page 31: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

31 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXNL-XXX-333mV series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20°C to 55°C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

vac

Page 32: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

APPLICATIONS / DIMENSIONS

32PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg 1 - / SJ 1 0 N L 00 0 333 mV

Model J S 1 0 N L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 1 6 N L 00 0 333 mV

Model J S 1 6 N L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 2 4 N L 00 0 333 mV

Model J S 2 4 N L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Current Transformer Ratios

5 0.05 00510 0.05 01020 0.05 02025 0.05 02530 0.05 03050 0.05 05075 0.05 075

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Current Transformer Ratios

70 0.05 070100 0.05 100

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

5 0.05 00510 0.05 01030 0.05 03050 0.05 05070 0.05 070

100 0.05 100150 0.05 150200 0.05 200

Unit : mm

ModelJS10NLJS16NLJS24NL

A40.54565

B2326

37.5

C23.73045

D26.631.633.7

E14.518.821.1

F150±20150±20200±20

Ød101624

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

10NL/16NLAWG#2224NLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

Page 33: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

SPLIT-CORE CURRENT TRANSFORMER

JSXXSL-XXX-333mV series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JS series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

33 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20°C to 55°C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

vac

HOW TO USE

Page 34: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

APPLICATIONS / DIMENSIONS

34PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg 1 - / SJ 2 4 S L 00 0 333 mV

Model J S 2 4 S L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 3 6 S L 00 0 333 mV

Model J S 3 6 S L

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Current Transformer Ratios

250 0.05 250300 0.05 300

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC 61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

300 0.05 300400 0.05 400500 0.05 500600 0.05 600

Unit : mm

ModelJS24SL

A65

B37.5

C45

D33.7

E21.1

Ød24

JS36SL 82.4 48 57.1 40.2 21.1

F200±20200±20 36

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

24SL/36SLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

Page 35: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

35 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• Steel spring plate, output-terminal, secure locking . hinge, one-touch structure make easy to install to existing equipment such as a power distribution board• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER

JM21X-XXX-333mV series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JM21X series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JM21X series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Latch/Unlatch

Test Voltage

Frequency Range

Protection Level

Insulation Category

IEC Class 0.5S / ANSI Class 0.6

Terminal Block(2P) - PART NUMBER : LM5.08/02/90 SW(black)

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2, IEEE/ANSI C57.13 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

about 100 times

3kV for 1minute

50/60Hz

5.1V0-P

CATⅡ or CATⅢ 600VAC

HOW TO USE

2 3

4 5

14

vac

Page 36: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

36PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

How to Order / Model Reference

eg - / J M 2 1 X 00 0 333 mV

Model J M 2 1 X

3 3 3 mVSecondary Voltage

333mV

Primary CurrentSelect code from ratio table

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

5 0.001 00515 0.01 01520 0.03 02030 0.05 03050 0.01 05070 0.01 070

100 0.02 100150 0.03 150200 0.04 200250 0.05 250

DIN RAIL MOUNTING Mount the bracket on the rail and install current transformer

PANEL MOUNTING Tighten screws on the hole to mount bracket and install current transformer

ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.

ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.

ㆍBe careful to install the product with the correct polarity.

ㆍDo not install the product if an application exceed the specications of the product.

ㆍRecommended to use the terminals specied by J&D.

Precautions for the Warranty of QualityYEARS

5

W A R R A N T Y

ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.

ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.

ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.

ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.

ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.

Check Point for the Accurate MeasurementP R O P E R T I E

S

ELECTRICAL

ㆍPlease provide the technical requirements for a technical evaluation.

ㆍThe color of housing is changeable upon the customer’s requirements.

ㆍThe leads can be mounted on the terminals by J&D.

ㆍA protective tailor-made housing is available.

Remarks for the Customized ProductsODM

ON RE Q UEST

INTERNAL CIRCUITDRAWING

28.4

9

95

80.5

4.7 7.2

19.7

2.5

• PANEL MOUNT

51.5

46

7035

35

24.27

• DIN RAIL MOUNT

S2S1

7060

64228

Optional lead wiresBlack & White orBrown & Yellow colors of UL1015#18

2840.3

23.8

14.5

2000 ± 50AWG

#18

8

Relay cable(common)(attached with CT)

Part-NO. : 56002(red)

BipolarDirectionalZenor Diode

S2S1

P2P1

BLACKWIRE

WHITEWIRE

I

Page 37: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Faster installation• Cost effective• Long product life

HOW TO USE

REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER

JSC-XX-XXXX-333mV series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JSC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

37 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Leads

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S

18AWG, 600VAC

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 60˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

2 3

4 5 6

1

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

vac

JSC-01-250-333mA250A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-02-800-333mA800A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-03-1600-333mA1600A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

Page 38: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

38PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

250 0.05 0250400 0.05 0400

Dimensions

3929

94

Dimensions Dimensions

933822

32

92

P1

P23929

124

196

141

22

62

124

P1

P2

3929

124

128

124

62

P1

P2

7322

How to Order / Model Reference

eg - - / J S C 0 1 0 00 0 333 mV

Model J S C - 0 1

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

400 0.05 0400600 0.05 0600800 0.05 0800

1000 0.05 10001200 0.05 1200

How to Order / Model Reference

eg - - / J S C 0 2 0 00 0 333 mV

Model J S C - 0 2

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400

How to Order / Model Reference

eg - - / J S C 0 3 0 00 0 333 mV

Model J S C - 0 3

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Page 39: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

39 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Faster installation• Cost effective• Long product life

HOW TO USE

REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER

JSC-XXN-XXXX-333mV series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JSC series of split-core current transformer offers 333mV at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Leads

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S

18AWG, 600VAC

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 60˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

2 3

4 5 6

1

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

vac

JSC-01N-250-333mA250A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-02N-800-333mA800A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-03N-1600-333mA1600A : 333mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

Page 40: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

40PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

250 0.05 0250400 0.05 0400

Dimensions

3929

94

Dimensions Dimensions

933822

32

92

P1

P23929

124

196

141

22

62

124

P1

P2

3929

124

128

124

62

P1

P2

7322

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

400 0.05 0400600 0.05 0600800 0.05 0800

1000 0.05 10001200 0.05 1200

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

333mV Secondary

800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400

How to Order / Model Reference

eg - - / J S C 0 1 N 0 00 0 333 mV

M J S C - 0 1 N

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 2 N 0 00 0 333 mV

M J S C - 0 2 N

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 3 N 0 00 0 333 mV

M J S C - 0 3 N

3 3 3 mVSecondary Voltage333mV

Primary CurrentSelect code from ratio table

Page 41: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

41 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• Nylon-spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JCXXF-XXX-100mA series

• If you impact the core contact surface, internal core material could be damaged.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing out put lead wire

JC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

JD120601

S1 S2

JC24F125A :100mA

200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV

JS17S-200/100mA

S1 S2

JD120601

S1 S2

JC16F125A :100mA

Page 42: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

42PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Dimensions

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Dimensions

31

19

P2 P1

55

41

29.5

S1 S2

1674

.5

5245

S1 S2

24

22

34

P2 P1

How to Order / Model Reference

eg - / J C 1 6 F 00 0 001 mA

Model J C 1 6 F

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J C 2 4 F 00 0 001 mA

Model J C 2 4 F

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

50 0.05 050100 0.05 100125 0.05 125

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

125 0.05 125200 0.05 200

Page 43: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

43 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

• Nylon-spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JCXXN-XXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Please use only the original output screws. Not recommanded to replace it with anything else.• Customizing out put lead wire

JC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

JD120601

S1 S2

JC24N125A :100mA

200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV

JS17S-200/100mA

S1 S2

JD120601

S1 S2

JC16N125A :100mA

Page 44: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

44PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Dimensions

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Dimensions

31

19

P2 P1

55

41

29.5

S1 S2

1674

.5

5245

S1 S2

24

22

34

P2 P1

How to Order / Model Reference

eg - / J C 1 6 N 00 0 001 mA

Model J C 1 6 N

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J C 2 4 N 00 0 001 mA

Model J C 2 4 N

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

50 0.05 050100 0.05 100125 0.05 125

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

125 0.05 125200 0.05 200

Page 45: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

45 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXF-XXX-100mA series

• If you impact the core surface, internal core material could be damaged.• Customizing output lead wire

JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

JS24F-200/100mA

S1 S2

200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VA F=50/60Hz Umax=720V Ui=3kV

150A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV

JS17F-150/100mA

S1 S2

Page 46: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

46PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

How to Order / Model Reference

eg - / J S 1 7 F 00 0 001 mA

Model J S 1 7 F

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 2 4 F 00 0 001 mA

Model J S 2 4 F

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

Current Transformer Ratios

50 0.05 050100 0.05 100125 0.05 125150 0.05 150

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Current Transformer Ratios

200 0.05 200

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Dimensions Dimensions

35.8

26.2

P2 P1

64.1

41.1

33.1

S1 S2

17

17

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

74.5

47

45

S1 S2

24

24

21.1

33.7

P2 P1

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

Page 47: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

47 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXS-XXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side.• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any parts.• Customizing output lead wire

JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

JS24S-250/100mA

S1 S2

250A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VA F=50/60Hz Umax=720V Ui=3kV

JS36S-500/100mA

S1 S2

500A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VA F=50/60Hz Umax=720V Ui=3kV

200A : 100mA Lot no:120601IEC60044-1 class 0.5S, 0.01VAF=50/60Hz Umax=720V Ui=3kV

JS17S-200/100mA

S1 S2

Page 48: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

48PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Current Transformer Ratios

200 0.05 200

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Current Transformer Ratios

250 0.05 250300 0.05 300

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

300 0.05 300400 0.05 400500 0.05 500600 0.05 600

Dimensions Dimensions Dimensions

35.8

26.2

P2 P1

64.1

41.1

33.1

S1 S2

17

17

91.4

57

57.1

S1 S2

36

36

21.140.2

P2 P1

74.5

47

45

S1 S2

24

24

21.1

33.7

P2 P1

How to Order / Model Reference

eg - / J S 1 7 S 00 0 001 mA

Model J S 1 7 S

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 2 4 S 00 0 001 mA

Model J S 2 4 S

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 3 6 S 00 0 001 mA

Model J S 3 6 S

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

BipolarDirectionalZenor Diode

M3 Screw M3 Screw

S2 S1

P2 P1

Page 49: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

49 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXFL-XXX-100mA series

• If you impact the core contact surface, internal core material could be damaged.• Customizing output lead wire

JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

Page 50: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

APPLICATIONS / DIMENSIONS

50PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg 1 - / SJ 1 6 F L 00 0 001 mA

Model J S 1 6 F L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 2 4 F L 00 0 001 mA

Model J S 2 4 F L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

Current Transformer Ratios

50 0.05 050100 0.05 100

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

200 0.05 200

Unit : mm

ModelJS16FLJS24FL

A4565

B26

37.5

C3045

D31.633.7

E18.821.1

F150±20200±20

Ød1624

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

16FLAWG#2224FLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

Page 51: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

51 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXNL-XXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20°C to 55°C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

Page 52: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

APPLICATIONS / DIMENSIONS

52PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg 1 - / SJ 1 6 N L 00 0 001 mA

Model J S 1 6 N L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 2 4 N L 00 0 001 mA

Model J S 2 4 N L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

Current Transformer Ratios

50 0.05 050100 0.05 100

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

200 0.05 200

Unit : mm

ModelJS16NLJS24NL

A4565

B26

37.5

C3045

D31.633.7

E18.821.1

F150±20200±20

Ød1624

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

16NLAWG#2224NLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

Page 53: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

SPLIT-CORE CURRENT TRANSFORMER

JSXXSL-XXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JS series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JS series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

53 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20°C to 55°C

0-85% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

HOW TO USE

Page 54: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

APPLICATIONS / DIMENSIONS

54PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg 1 - / SJ 2 4 S L 00 0 001 mA

Model J S 2 4 S L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg 1 - / SJ 3 6 S L 00 0 001 mA

Model J S 3 6 S L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

Current Transformer Ratios

250 0.05 250300 0.05 300

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

300 0.05 300400 0.05 400500 0.05 500600 0.05 600

Unit : mm

ModelJS24SL

A65

B37.5

C45

D33.7

E21.1

Ød24

JS36SL 82.4 48 57.1 40.2 21.1

F200±20200±20 36

BipolarDirectionalZenor Diode

White wire

(S1)Black wire

(S2)

P1 P2

ED

P2

P1

1000

± 5

0

AWG

#22

Relay cable(common)(attached with CT)

Receptacle housing :SLR-02VFPin contact :SSM-21T-P1.4

Housing : 5480-02(Molex.Inc.)Terminal : 5479PBT(Molex.Inc.)

A F

B

C Φd

24SL/36SLAWG#18

Plug housing :SLP-02VSocket connector : SSF-21T-P1.4

Whi

te w

ire

(S1)

Blac

k w

ire

(S2)

OPTION

LOAD

S1 S2

CONTACTOR

CurrentMonitoring

POWER

Page 55: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

55 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• Steel spring plate, output-terminal, secure locking . hinge, one-touch structure easily to install to existing equipment such as a power distribution board• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER

JM21X-XXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JM21X series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JM21X series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Latch/Unlatch

Test Voltage

Frequency Range

Protection Level

Insulation Category

IEC Class 0.5S / ANSI Class 0.6

Terminal Block(2P) - PART NUMBER : LM5.08/02/90 SW(black)

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2, IEEE/ANSI C57.13 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

about 100 times

3kV for 1minute

50/60Hz

5.1V0-P

CATⅡ or CATⅢ 600VAC

HOW TO USE

2 3

4 5

14

S2

S1

Page 56: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

56PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

How to Order / Model Reference

eg - / J M 2 1 X 00 0 001 mA

Model J M 2 1 X

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

DIN RAIL MOUNTING Mount the bracket on the rail and install current transformer

PANEL MOUNTING Tighten screws on the hole to mount bracket and install current transformer

ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.

ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.

ㆍBe careful to install the product with the correct polarity.

ㆍDo not install the product if an application exceed the specications of the product.

ㆍRecommended to use the terminals specied by J&D.

Precautions for the Warranty of QualityYEARS

5

W A R R A N T Y

ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.

ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.

ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.

ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.

ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.

Check Point for the Accurate MeasurementP R O P E R T I E S

ELECTRICAL

ㆍPlease provide the technical requirements for a technical evaluation.

ㆍThe color of housing is changeable upon the customer’s requirements.

ㆍThe leads can be mounted on the terminals by J&D.

ㆍA protective tailor-made housing is available.

Remarks for the Customized ProductsODM

ON RE Q U EST

BipolarDirectionalZenor Diode

BLACKWIRE

WHITEWIRE

S2S1

P2P1

INTERNAL CIRCUITDRAWING

28.4

9

95

80.5

4.7 7.2

19.7

2.5

• PANEL MOUNT

51.5

46

7035

35

24.27

• DIN RAIL MOUNT

S2S1

7060

64228

Optional lead wiresBlack & White orBrown & Yellow colors of UL1015#18

2840.3

23.8

14.5

2000 ± 50AWG

#18

8

Relay cable(common)(attached with CT)

Part-NO. : 56002(red)

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

50 0.01 05070 0.01 070

100 0.01 100125 0.01 125150 0.01

0.020.020.050.050.05 150

200 0.05 200250 0.05 250

Page 57: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Faster installation• Cost effective• Long product life

HOW TO USE

REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER

JSC-XX-XXXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JSC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

57 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Leads

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S

18AWG, 600VAC

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 60˚C

0-90% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

2 3

4 5 6

1

JSC-01-250-100mA250A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-02-800-100mA800A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-03-1600-100mA1600A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

Page 58: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

58PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

250 0.05 0250400 0.05 0400

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

400 0.05 0400600 0.05 0600800 0.05 0800

1000 0.05 10001200 0.05 1200

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400

Dimensions

3929

94

Dimensions Dimensions

933822

32

92

P1

P23929

124

196

141

22

62

124

P1

P2

3929

124

128

124

62

P1

P2

7322

How to Order / Model Reference

eg - - / J S C 0 1 0 00 0 001 mA

Model J S C - 0 1

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 2 0 00 0 001 mA

Model J S C - 0 2

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 3 0 00 0 001 mA

Model J S C - 0 3

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

Page 59: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

59 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Faster installation• Cost effective• Long product life

HOW TO USE

REVENUE-GRADESPLIT-CORE CURRENT TRANSFORMER

JSC-XXN-XXXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts.• Customizing output lead wire

JSC series of split-core current transformer offers 100mA at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JSC series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Leads

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S

18AWG, 600VAC

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 60˚C

0-90% non-condensing

3kV for 1minute

50/60Hz

3.0V0-P

CATⅡ or CATⅢ 600VAC

2 3

4 5 6

1

JSC-01N-250-100mA250A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-02N-800-100mA800A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

JSC-03N-1600-100mA1600A : 100mA Lot no : 120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

E344623

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

600V

AC M

ax. C

ATA

dditi

onal

isol

atio

n m

ust b

e pr

ovid

ed if

use

d at

hig

her v

olta

ges.

P1P2

Page 60: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

60PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

250 0.05 0250400 0.05 0400

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

400 0.05 0400600 0.05 0600800 0.05 0800

1000 0.05 10001200 0.05 1200

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

800 0.05 08001000 0.05 10001200 0.05 12001600 0.05 16002000 0.05 20002400 0.05 2400

Dimensions

3929

94

Dimensions Dimensions

933822

32

92

P1

P23929

124

196

141

22

62

124

P1

P2

3929

124

128

124

62

P1

P2

7322

How to Order / Model Reference

eg - - / J S C 0 1 N 0 00 0 001 mA

M J S C - 0 1 N

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 2 N 0 00 0 001 mA

M J S C - 0 2 N

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 3 N 0 00 0 001 mA

M J S C - 0 3 N

1 0 0 mASecondary Current

100mA

Primary CurrentSelect code from ratio table

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

BipolarDirectionalZenor Diode

(S2)Black wire

(S1)White wireP1

P2

Page 61: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

61 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JCXXS-XXX-1A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JC series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

Page 62: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

62PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

How to Order / Model Reference

eg - / J C 2 4 S 0 0 0 0 A

Model J C 2 4 S

1 ASecondary Current1A

Primary CurrentSelect code from ratio table

100 1.0 100250 1.0 250

Dimensions

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

How to Order / Model Reference

eg - / J C 3 6 S 0 0 0 0 A

Model J C 3 6 S

1 ASecondary Current1A

Primary CurrentSelect code from ratio table

400 0.5 400500 0.5 500600 0.5 600

Dimensions

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

91

6257

S1 S2

36

2240.5

P2 P1

74.5

52

45

S1 S2

24

22

34

P2 P1

Page 63: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

63 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXS-XXX-1A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JS series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

JS24S-200/1A

S1 S2

200A : 1A Lot no:120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV

JS36S-500/1A

S1 S2

500A : 1A Lot no:120601IEC60044-1 class 0.5, 0.5F=50/60Hz Umax=720V Ui=3kV

VA 125A : 1A Lot no:120601IEC60044-1 class 3.0, 1.0VA

F=50/60Hz Umax=720V Ui=3kV

JS17S-125/1A

S1 S2

Page 64: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

64PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

How to Order / Model Reference

eg - / J S 1 7 S 0 0 0 0 A

Model J S 1 7 S

1 ASecondary Current1A

Primary CurrentSelect code from ratio table

Dimensions

How to Order / Model Reference

eg - / J S 2 4 S 0 0 0 0 A

Model J S 2 4 S

1 ASecondary Current1A

Primary CurrentSelect code from ratio table

Dimensions

74.5

47

45

S1 S2

24

24

21.1

33.7

P2 P1

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

How to Order / Model Reference

eg - / J S 3 6 S 0 0 0 0 A

Model J S 3 6 S

1 ASecondary Current1A

Primary CurrentSelect code from ratio table

Dimensions

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

35.8

26.2

P2 P1

64.1

41.1

33.1

S1 S2

17

17

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

21.140.2

P2 P1

91.4

57

57.1

S1 S2

36

36

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

60 0.2 06075 0.5 075

100 0.5 100125 1.0 125150 1.0 150200 1.0 200

100 1.0 100125 1.0 125150 1.0 150200 0.5 200250 1.0 250300 1.5 300

300 1.5 300400 0.5 400500 0.5 500600 0.5 600

Page 65: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

65 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Latch/Unlatch

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0 / 3.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

about 100 times

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JS18S-XXX-1A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JS series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

Page 66: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

66PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

How to Order / Model Reference

eg - / J S 1 8 S 0 0 0 0 A

Model J S 1 8 S

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

100 0.2 10075 0.2 07560 0.2 06050 0.2 050

125 0.2 125150 0.2 150200 0.2 200

Installation

The Sample of customized product

ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.

ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.

ㆍBe careful to install the product with the correct polarity.

ㆍDo not install the product if an application exceed the specications of the product.

ㆍRecommended to use the terminals specied by J&D.

Precautions for the Warranty of QualityYEARS

5

W A R R A N T Y

ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.

ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.

ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.

ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.

ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.

Check Point for the Accurate MeasurementP R O P E R T I E S

ELECTRICAL

ㆍPlease provide the technical requirements for a technical evaluation.

ㆍThe color of housing is changeable upon the customer’s requirements.

ㆍThe leads can be mounted on the terminals by J&D.

ㆍA protective tailor-made housing is available.

Remarks for the Customized ProductsODM

ON RE Q UEST

TRIAC

SC

M3Screw

M3Screw

S2 S1

P2 P1

INTERNAL CIRCUITDRAWING

S1S2

METER

P2P1

METER

P2P1

35.8

26

P2 P1S1 S2

77.6

49.1

44.1

18

18

JS18S + Optional Leadwire

ㆍStandard length of lead wire is 2M, but the length may be altered according to the customer’s needs.

ㆍThe lead wire connections are protected by a terminal cover which is secured with a sticker label.

(unit : mm)

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Page 67: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

67 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• Steel spring plate, output-terminal, secure locking . hinge, one-touch structure easily to install to existing equipment such as a power distribution board• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

SPLIT-CORE CURRENT TRANSFORMER

JM21N-XXX-1A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JM21N series of split-core current transformer offers 1A at secondary from sensed primary current. Without using secondary CT inside of meter, users directly connect JM21N series to a meter for high accuracy metering application. It enables one meter to be adopted for various current rating by only changing primary CT so it makes compact design meter and reduces developing cost. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Latch/Unlatch

Test Voltage

Frequency Range

Protection Level

Insulation Category

IEC Class 0.5S / ANSI Class 0.6

Terminal Block(2P) - PART NUMBER : LM5.08/02/90 SW(black)

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2, IEEE/ANSI C57.13 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

about 100 times

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

HOW TO USE

2 3

4 5

14

Page 68: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

68PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

DIN RAIL MOUNTING Mount the bracket on the rail and install current transformer

PANEL MOUNTING Tighten screws on the hole to mount bracket and install current transformer

ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.

ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.

ㆍBe careful to install the product with the correct polarity.

ㆍDo not install the product if an application exceed the specications of the product.

ㆍRecommended to use the terminals specied by J&D.

Precautions for the Warranty of QualityYEARS

5

W A R R A N T Y

ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.

ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.

ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.

ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.

ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.

Check Point for the Accurate MeasurementP R O P E R T I E S

ELECTRICAL

ㆍPlease provide the technical requirements for a technical evaluation.

ㆍThe color of housing is changeable upon the customer’s requirements.

ㆍThe leads can be mounted on the terminals by J&D.

ㆍA protective tailor-made housing is available.

Remarks for the Customized Products

ODMON RE Q U EST

INTERNAL CIRCUITDRAWING

28.4

9

95

80.5

4.7 7.2

19.7

2.5

• PANEL MOUNT

51.5

46

7035

35

24.27

• DIN RAIL MOUNT

S2S1

7060

64228

Optional lead wiresBlack & White orBrown & Yellow colors of UL1015#18

2840.3

23.8

14.5

2000 ± 50AWG

#18

8

Relay cable(common)(attached with CT)

Part-NO. : 56002(red)

TRIAC

SC

P2P1

S2S1

BLACKWIRE

WHITEWIRE

I

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

How to Order / Model Reference

eg - / J M 2 1 N 0 0 0 0 A

Model J M 2 1 N

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

100 0.2 100125 0.2 125150 0.2 150200 0.2 200250 0.2 250

Page 69: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

69 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Faster installation• Cost effective• Long product life

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSC-XX-XXXX-1A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JSC series of split-core current transformer offers 1A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Leads

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

18AWG, 600VAC

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 60˚C

0-90% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

2 3

4 5 6

1

JSC-01-300-1A300A : 1A Lot no : 120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

JSC-02-800-1A800A : 1A Lot no : 120601IEC60044-1 class 0.5, 1.0VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

JSC-03-1600-1A1600A : 1A Lot no : 120601IEC60044-1 class 0.5, 10VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

Page 70: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

70PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Dimensions

3929

94

Dimensions Dimensions

TRIACSC

Black wire

(S2)White wire

(S1)

P2

P1

How to Order / Model Reference

eg - - / J S C 0 1 0 0 0 10 A

Model J S C - 0 1

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

933822

32

92

P1

P2

TRIACSC

Black wire

(S2)White wire

(S1)

P2

P1

3929

124

196

141

22

62

124

P1

P2

TRIACSC

Black wire

(S2)White wire

(S1)

P2

P1

3929

124

128

124

62

P1

P2

7322

How to Order / Model Reference

eg - - / J S C 0 2 0 0 0 10 A

Model J S C - 0 2

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 3 0 0 0 10 A

Model J S C - 0 3

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

100 0.5 0100150 1.5 0150200 0.5 0200250 0.5 0250300 0.5 0300400 0.5 0400

400 1.0 0400500 2.5 0500600 1.0 5.0 0600750 1.0 5.0 0750800 1.0 5.0 0800

1000 2.5 10.0 1000

800 1.0 5.0 08001000 1.0 5.0 10001200 5.0 10.0 12001250 5.0 10.0 12501500 10.0 20.0 15001600 10.0 20.0 16002000 10.0 20.0 20002400 10.0 20.0 2400

Page 71: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

71 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXS-XXX-5A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JS series of split-core current transformer offers 5A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

150A : 5A Lot no:120601IEC60044-1 class3.0, 1.5VA

F=50/60Hz Umax=720V Ui=3kV

JS17S-150/5A

S1 S2

JS24S-400/5A

S1 S2

400A : 5A Lot no:120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV

JS36S-500/5A

S1 S2

500A : 5A Lot no:120601IEC60044-1 class 0.5, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Page 72: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

72PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

TRIAC

SC

M3 Screw M3 Screw

S2 S1

P2 P1

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

How to Order / Model Reference

eg - / J S 1 7 S 0 0 0 0 A

Model J S 1 7 S

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

Dimensions

How to Order / Model Reference

eg - / J S 2 4 S 0 0 0 0 A

Model J S 2 4 S

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

Dimensions

74.5

47

45

S1 S2

24

24

21.1

33.7

P2 P1

How to Order / Model Reference

eg - / J S 3 6 S 0 0 0 0 A

Model J S 3 6 S

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

Dimensions

35.8

26.2

P2 P1

64.1

41.1

33.1

S1 S2

17

17

21.140.2

P2 P1

91.4

57

57.1

S1 S2

36

36

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

150 0.2 150 100 1.5 100150 1.5 150200 0.5 200250 0.5 250300 0.5 300400 0.5 400

300 0.5 300400 0.5 400

200 2.5 200250 0.5 250

500 0.5 500600 0.5

2.52.55.0 600

Page 73: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

73 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Latch/Unlatch

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0 / 3.0

2 X M3-Screw, with Terminals cover

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

about 100 times

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

• PC spring, output-terminal, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0• UL / EN 61010 - 1 certified

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSXXS-XXX-5A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JS series of split-core current transformer offers 5A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

2 3

4 5 6

1

P2 P1

METER

S1 S2 M3-Screwdriver

8mm

Terminalcover

CLOSE

Terminalcover

OPEN

Page 74: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS

74PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

How to Order / Model Reference

eg - / J S 1 8 S 0 0 0 0 A

Model J S 1 8 S

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

100 1.0 10075 1.0 7550 1.0 50

150 1.0 125200 1.0 150250 1.0 200

Installation

The Sample of customized product

ㆍSplit-core CT must be handled with care. A damage caused from the careless handling will not be covered by warranty.

ㆍThe product is designed to meet operating environments dened by the industrial standard IP20.

ㆍBe careful to install the product with the correct polarity.

ㆍDo not install the product if an application exceed the specications of the product.

ㆍRecommended to use the terminals specied by J&D.

Precautions for the Warranty of QualityYEARS

5

W A R R A N T Y

ㆍProtection circuit built in inside of the product for user safety. An additional external protection circuit would be impacted on the feature.

ㆍThe product is designed for measuring sinusoidal 50/60Hz of primary current. Be aware that it is possible to occur the signicant error if it is used to measure non-sinusoidal.

ㆍUse Split-core CT with proper diameter to t the conductor, otherwise it may cause the ratio error and the phase shift.

ㆍBe careful to install Split-core CT without any pollutions on the core surfaces. The pollutions such as moisture, dust and rusty can be caused the error. After removing the pollutions, recommended to use WD-40 or CRC5-56 on the core surfaces.

ㆍCheck whether the secondary leads is connected correctly or not. If the connection is not correctly, the secondary output could be lower than the expected one.

Check Point for the Accurate MeasurementP R O P E R T I E

S

ELECTRICAL

ㆍPlease provide the technical requirements for a technical evaluation.

ㆍThe color of housing is changeable upon the customer’s requirements.

ㆍThe leads can be mounted on the terminals by J&D.

ㆍA protective tailor-made housing is available.

Remarks for the Customized ProductsODM

ON RE Q U EST

TRIAC

SC

M3Screw

M3Screw

S2 S1

P2 P1

INTERNAL CIRCUITDRAWING

S1S2

METER

P2P1

METER

P2P1

35.8

26

P2 P1S1 S2

77.6

49.1

44.1

18

18

JS18S + Optional Leadwire

ㆍStandard length of lead wire is 2M, but the length may be altered according to the customer’s needs.ㆍThe lead wire connections are protected by

a terminal cover which is secured with a sticker label.

(unit : mm)

Page 75: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

75 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• High quality comprehensive measurement• Available in a wide range of transformer ratings• Accuracy up to Class 0.5S

APPLICATIONS• Power meter• Switchgear• Distributed measurement systems• General Sets• Control panels

FEATURES

NOTICE

BENEFITS• Faster installation• Cost effective• Long product life

HOW TO USE

SPLIT-CORE CURRENT TRANSFORMER

JSC-XX-XXXX-5A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

JSC series of split-core current transformer offers 5A at secondary from sensed primary current for metering application. It can be used for power meter, distribution system, control panels, switchgear and other equipment. It is designed to install to live power line without disconnection as split-core compact type. Also, over-voltage protection circuit is included to offer safe, fast and cost effective installation.

SPECIFICATION

Accuracy

Leads

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

18AWG,600VAC

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 60˚C

0-90% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅡ or CATⅢ 600VAC

2 3

4 5 6

1

JSC-01-300-5A300A : 5A Lot no : 120601IEC60044-1 class 1.0, 0.5VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

JSC-02-800-5A800A : 5A Lot no : 120601IEC60044-1 class 0.5, 1.0VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

JSC-03-1600-5A1600A : 5A Lot no : 120601IEC60044-1 class 0.5, 10VA F=50/60Hz Umax=720V Ui=3kV

Source Side S1 : White S2 : Black

Page 76: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

76PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13 meets the measur-ing range from 1 to 120 % of In

Dimensions

3929

94

Dimensions Dimensions

TRIACSC

Black wire

(S2)White wire

(S1)

P2

P1

How to Order / Model Reference

eg - - / J S C 0 1 0 0 0 50 A

Model J S C - 0 1

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

933822

32

92

P1

P2

TRIACSC

Black wire

(S2)White wire

(S1)

P2

P1

3929

124

196

141

22

62

124

P1

P2

TRIACSC

Black wire

(S2)White wire

(S1)

P2

P1

3929

124

128

124

62

P1

P2

7322

How to Order / Model Reference

eg - - / J S C 0 2 0 0 0 50 A

Model J S C - 0 2

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - - / J S C 0 3 0 0 0 50 A

Model J S C - 0 3

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

100 0.5 0100150 1.5 0150200 1.5 0200250 0.5 0250300 0.5 0300400 0400

400 1.0 0400500 2.5 0500600 1.0 5.0 0600750 1.0 5.0 0750800 1.0 5.0 0800

1000 2.5 10.0 1000

800 1.0 5.0 08001000 1.0 5.0 10001200 5.0 10.0 12001250 5.0 10.0 12501500 10.0 20.0 15001600 10.0 20.0 16002000 10.0 20.0 20002400 10.0 20.0 2400

Page 77: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

• The mating surfaces of the transformer cores are protected by a rubber gasket.• The transformer cases are UV stabilized thermoplastic.• Water proof (IP67 or IP65 Option)

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

PRECISION OUTDOOR USESPLIT-CORE CURRENT TRANSFORMER

JSXXL-XXX-100mA series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

The JSXXL series Water proof Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.These current transformers are a water proof design suitable for use outdoor or in direct burial applications.

77 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 1.0

Twisted pair, 18AWG cable

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅣ 300VAC

Adding perfect Gasket forpreventing core erosion

200A : 100mA Lot no:120601IEC60044-1 class 1.0S, 0.05VAF=50/60Hz Umax=720V Ui=3kV

JS21L-200/100mA

S1 S2

Page 78: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

CURRENT TRANSFORMER RATIOS / DIMENSIONS

78PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg - / J S 2 1 L 00 0 001 mA

Model J S 2 1 L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 3 2 L 00 0 001 mA

Model J S 3 2 L

1 0 0 mASecondary Current100mA

Primary CurrentSelect code from ratio table

Current Transformer Ratios

100 0.05 100125 0.05 125150 0.05 150200 0.05 200250 0.05 250300 0.05 300

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Dimensions Dimensions

Bipo

lar

Dire

ctio

nal

Zeno

r Dio

de

S2S1

P2P1

Yellow wire

(S1)

Brown wire

(S2) Bipo

lar

Dire

ctio

nal

Zeno

r Dio

de

S2S1

P2P1

Yellow wire

(S1)

Brown wire

(S2)

Current Transformer Ratios

cl. 0.2S cl. 0.5S cl. 1

cl. 0.3 cl. 0.6 cl. 1.2

Metering Burden(VA)PrimaryCurrent

(A)Code

100mA Secondary

300 0.05 300400 0.05 400500 0.05 500600 0.05 600

98

932

32

62

1.5

36.5

40.4 5.2

54.4

21

21

78.5

4929

.5

1.6 8

1.5

2933

5.2

47

50

Page 79: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

79 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

• The mating surfaces of the transformer cores are protected by a rubber gasket.• The transformer cases are UV stabilized thermoplastic.• Water proof (IP67 or IP65 Option)

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

PRECISION OUTDOOR USESPLIT-CORE CURRENT TRANSFORMER

JSXXL-XXX-1A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

The JSXXL series Water proof Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.These current transformers are a water proof design suitable for use outdoor or in direct burial applications.

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

Twisted pair, 18AWG cable

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅣ 300VAC

Adding perfect Gasket forpreventing core erosion

250A : 1A Lot no:120601IEC60044-1 class 1.0S, 1.0VAF=50/60Hz Umax=720V Ui=3kV

JS21L-250/1A

S1 S2

Page 80: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

80PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

CURRENT TRANSFORMER RATIOS / DIMENSIONS

How to Order / Model Reference

eg - / J S 2 1 L 0 0 0 0 A

Model J S 2 1 L

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 3 2 L 0 0 0 0 A

Model J S 3 2 L

1 ASecondary Current

1A

Primary CurrentSelect code from ratio table

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Dimensions Dimensions98

932

32

62

1.5

36.5

40.4 5.2

54.4

21

21

78.5

4929

.5

1.6 8

1.5

2933

5.2

47

50

100 1.0 100125 1.0 125150 1.0

1.0150

200 200250 1.0 250300 1.5 300

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

1A Secondary

300 1.5 300400 0.5 400500 0.5 500600 0.5 600

TRIA

C SC

S2S1

P2P1

Yellow wire

(S1)

Brown wire

(S2)

TRIA

C SC

S2S1

P2P1

Yellow wire

(S1)

Brown wire

(S2)

Page 81: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

• The mating surfaces of the transformer cores are protected by a rubber gasket.• The transformer cases are UV stabilized thermoplastic.• Water proof (IP67 or IP65 Option)

APPLICATIONS• Energy sub - meter• Power meters• Power quality monitoring• HVAC&Pumps, etc• Distributed measurement system

FEATURES

NOTICE

BENEFITS• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

HOW TO USE

PRECISION OUTDOOR USESPLIT-CORE CURRENT TRANSFORMER

JSXXL-XXX-5A series

• Core contact surface is waterproofed, however if it gets rusty, you could reuse after removing rusts with spraying WD-40 or CRC5-56 on the rusted side• Do not use any other chemicals except WD-40 or CRC5-56 on housing or any other parts• Customizing output lead wire

The JSXXL series Water proof Split Core Current Transformers are designed for assembly to an existing electrical installation without the need for dismantling the primary bus or cables.These current transformers are a water proof design suitable for use outdoor or in direct burial applications.

81 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

SPECIFICATION

Accuracy

Output Terminals

System Voltage

Overload withstand

Compliant with

Operating Temperature Range

Relative Humidity

Test Voltage

Frequency Range

Protection Level

Insulation Category

Class 0.5S / 1.0 / 3.0

Twisted pair, 18AWG cable

720V(0.72kV)

1.2 times rated current continuously

IEC/EN61869-2 & IEC61010-1

-20˚C to 55˚C

0-85% non-condensing

3kV for 1minute

50/60Hz

Bipolar 6.5Vp

CATⅣ 300VAC

Adding perfect Gasket forpreventing core erosion

250A : 5A Lot no:120601IEC60044-1 class 1.0S, 0.5VAF=50/60Hz Umax=720V Ui=3kV

JS21L-250/5A

S1 S2

Page 82: PRECISE SPLIT-CORE AC CURRENT TRANSFORMER · 1 PRECISE SPLIT-CORE AC CURRENT TRANSFORMER PRECISE SPLIT-CORE AC CURRENT TRANSFORMER Miniature Split-core AC Current Transformer is suitable

TRIA

C SC

S2S1

P2P1

Yellow wire

(S1)

Brown wire

(S2)

TRIA

C SC

S2S1

P2P1

Yellow wire

(S1)

Brown wire

(S2)

CURRENT TRANSFORMER RATIOS / DIMENSIONS

82PRECISE SPLIT-CORE AC CURRENT TRANSFORMER

How to Order / Model Reference

eg - / J S 2 1 L 0 0 0 0 A

Model J S 2 1 L

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

How to Order / Model Reference

eg - / J S 3 2 L 0 0 0 0 A

Model J S 3 2 L

5 ASecondary Current

5A

Primary CurrentSelect code from ratio table

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Accuracy conforms to IEC61869-2 & IEEE/ANSI C57.13meets the measuring range from 1 to 120 % of In

Dimensions Dimensions

98

932

32

62

1.5

36.5

40.4 5.2

54.4

21

21

78.5

4929

.5

1.6 8

1.5

2933

5.2

47

50

Current Transformer Ratios

cl. 0.5S cl. 1 cl. 3

cl. 0.6 cl. 1.2 cl. 2.4

Metering Burden(VA)PrimaryCurrent

(A)Code

5A Secondary

100 1.5 100150 1.5

1.5150

200 200250 0.5 250300 0.5 300400 0.5 400

200 2.5 200250 0.5 250300 0.5 300400 0.5 2.5 400500 0.5 2.5 500600 0.5 5.0 600