Pre-Installation Manual GS-Series Pinsetters...2018/05/08 · GS-Series Pinsetters and Associated...
Transcript of Pre-Installation Manual GS-Series Pinsetters...2018/05/08 · GS-Series Pinsetters and Associated...
Pre-Installation Manual
GS-Series Pinsettersand Associated Brunswick Bowling Equipment
Electrical Requirements
May 2018 / 10-095400-041
2 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Brunswick GS-Series Pinsetters and Associated Brunswick Bowling Equipment Electrical Requirements Pre-Installation Manual
©May2018bytheBrunswickBowlingProducts.Allrightsreserved.
Reorder Part No. 10-095400-041
Notice:Ifavailable,updatestothismanualcanbefoundon-lineatwww.brunswickbowling.com.
Confidentialproprietaryinformation.Allinformationcontainedinthisdocumentissubjecttochangewithoutnotice.
BrunswickBowlingProducts525WestLaketonAvenueMuskegon,MI49441-2601U.S.A.
231.725.3300
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 3
SafEtyThroughoutthispublication,“Warnings”,and“Cautions”(accompaniedbyoneoftheInternationalHAZARDSymbols)areusedtoalertthemechanictospecialinstructionsconcerningaparticularserviceoroperationthatmaybehazardousifperformedincorrectlyorcarelessly.Theyaredefinedbelow.OBSERVE AND READ THEM CAREFULLY!
These“SafetyAlerts”alonecannoteliminatethehazardsthattheysignal.Strictcompliancetothesespecialinstructionswhenperformingtheservice,plustrainingand“CommonSense”operationaremajoraccidentpreventionmeasures.
NOTE or IMPORTANT!: Will designate significant informational notes.
WARNING! Will designate a mechanical or nonelectrical alert which could potentially
cause personal injury or death.
WARNING! Will designate electrical alerts which could potentially cause personal injury or
death.
CAUTION! Will designate an alert which could potentially cause product damage.
Will designate grounding alerts.
4 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
SafEty REquiREmEntS foR GS-SERiES PinSEttERSAswithallmachinery,acertainamountofriskisinvolvedinworkingontheGS-SeriesPinsetter.However,ifthenecessarycare,knowledgeandresponsibilityareexercised,damagetothepinsetterandpeopleinvolvedinaccidentscanbeavoided.Thefollowingstepsshouldbetaken:
Safety Guidelines 1. ONLYPROPERLYTRAINEDPEOPLEAREQUALIFIEDTOWORKONOROPERATE
THEPINSETTER
2. NeveroperatethepinsetterwithoutALLfactorysuppliedguardinginplace.
3. Neveroperatethepinsetterisaguardorsafetydeviceisdamagedorimproperlyfittedtothemachine.
4. Neverbypass,disable,ortamperwiththesafetyinterlocksorpinsetterfunctionswitches.
5. Neverattempttoclimboveroraroundanymechanicalbarrierormachineguard.
6. Reinstallallthemachineguardsandtheladderafteranytroubleshootingormaintenanceworkhasbeendoneonthepinsetter(s)orballaccelerator.
7.Alwaysfacetowardthemachinewhenusingtheladdertoclimbontooroffthemachine.Onlyonepersonshouldbeontheladderatanytime.
8. Suitableclothingmustbeworn(forexample:rubber-soledshoes).Donotwearlooseclothing
suchasnecktiesorsmocksthatcouldgetcaughtinmovingparts.Removerings,watches,earrings,braceletsandotherjewelrytoavoidinjury.
9. Careshouldbetakenwhilenearthefrontofthemachine.Accidentallyblockingthephotocellbeamwithwillcausethepinsettertocycle.
10. AlwaysturnthePinsetteroffbeforeworkingonthemachine.UsetherearLCDDisplaymountedonthepinelevatorortogglethestop/runswitchontheNexgenboxtothestopposition.
11. Ifmorethanonepersonisworkingonamachineorifastop/runswitchwillbeoutofreachwhileworkingonthemachine,lockoutSafetyControllerpowerswitchtopreventapersonfromturningonthepinsetterbeforetheotherpersonsayshe/sheisclearofthepinsetter.
12. Whenworkingonbothmachinesofalanepairorcomponentsthatarecommontobothmachines(forexample-anelectroniccontrolboxorballaccelerator)powermustbeturnedoffattheNexgenboxandtheinputpowercablemustbelockedoutontheSafetyControllerpowerswitch.
13. Thesweepboardsforthelanepairmustbedroppedtotheguardingpositionwhenworkingonthepinsetterortheballacceleratortopreventabowlingballfromenteringthepinsetter.
14. Priortoperformingserviceworkunderneaththesettingtable,placeajackstandorothersuitablesupportunderthecenterofthetable.
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 5
15. Fireextinguishersmustbeonhandandmaintainedproperly.Keepoilyragsandothercombustiblesinapprovedfireproofcontainers.
16. Ifmorethanonepersonisworkingonamachine,besuretheotherpersonisCLEARbeforerestartingthemachine.
17. Whenworkinginthepinsetterareawhilemachinesareinoperation,earprotectionshouldbeworn.Soundlevelsgreaterthan83dbcanbeexperiencedwithin1.6metersofoperatingmachines.
18. NeverremovetheV-beltfromthesettingtablemotorwithoutfirstloweringthetabletothenewpinsettingposition(pindeck).
19. Neverworkonoraroundthepinsetterwhileundertheinfluenceofalcohol,drugs,oranyothersubstancethatcanimpairyourphysicalabilitiesormentaljudgment.
20. Alwaysusethecorrecttoolsforthejob.
21. TheGS-Seriespinsetterisdesignedforuseasa10pinbowlingmachine.Donotusethemachineoranyofitssubassembliesforanyotherpurpose.
22. Poisonousortoxiccleanersmustnotbeused.Alwayscheckthematerialsafetydatasheetsbeforeusingnewcleaners.
23. Alwaysusefactoryapprovedpartswhenrepairingthepinsetter.Usingsubstandardpartsmayposeasafetyrisk.
24. Alwaysmakesurethatabowlerisnotpositionedtothrowaballbeforeputtingyourselfbetweenthebowlerandthemachine.Itisgoodpracticestohaveanotheremployeepositionednearanybowlertoensuretheycannotthrowaballand/orplaceasignontheapproachtoindicatethelaneisnotavailableforbowling.
6 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
CEntER mEChaniCTheGS-XPinsetterSafetyControllersystemmustbecommissionedandservicedonlybycentermechanic.
CenterMechanicsaredefinedaspersonswho • haveundergonetheappropriatetechnicaltrainingand • whohavebeeninstructedbytheresponsiblepinsetteroperatorintheoperationofthepinsetter
andthecurrentvalidsafetyguidelines and • whohaveaccesstothe“SafetyPhotoelectricSwitchSystemL4000”operatinginstructions.
General Safety information and Protective measuresSafety NotesPleaseobservethefollowingproceduresinordertoensurethecorrectandsafeuseoftheGS-XPinsetterPowerControllersystem. • Thenational/internationalrulesandregulationsapplytotheinstallation,commissioning,use
andperiodictechnicalinspectionsoftheGS-XPinsetterSafetyControllersystem,inparticular • MachineDirective98/37/EEC • EquipmentUsageDirective89/655/EEC • theworksafetyregulations/safetyrules • otherrelevanthealthandsafetyregulations
• UsersofthepinsetterwithwhichtheGS-XPinsetterSafetyControllersystemisusedareresponsibleforobtainingandobservingallapplicablesafetyregulationsandrules
• Itisimperativethatthetestnotesfrom2.3and2.4oftheseoperatinginstructions(Testsbeforethefirstcommissioning.Functionalchecksoftheprotectivedevice.)areobserved.
• Thetestsmustbecarriedoutbythecentermechanicandmustberecordedanddocumentedtoensurethatthetestscanbereconstructedandretracedatanytime.
• TheoperatinginstructionsmustbemadeavailabletotheuserofthepinsetterswhereGS-XPinsetterSafetyControllersystemisused.Thepinsetteroperatoristobeinstructedintheuseofthedevicebycentermechanicandmustbeinstructedtoreadtheoperatinginstructions.
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 7
ContEntSSafety................................................................................................................................................3SafetyRequirementsforGS-SeriesPinsetters..................................................................................4SafetyGuidelines...........................................................................................................................4
CenterMechanic...............................................................................................................................6GeneralSafetyInformationandProtectiveMeasures....................................................................6
Introduction ..............................................................................................................................8InterferenceInformation...................................................................................................................9NEC250-74ExceptionNo.4........................................................................................................9SurgeSuppression..........................................................................................................................9
SafetyWarningLabels....................................................................................................................10WarningLabelLocation-11-682565-000...................................................................................10
ElevatorWarningLabels.................................................................................................................11ElevatorGuardWarningLabel-11-682498-000.........................................................................11ElevatorGuardWarningLabel-11-682566-000.........................................................................12ElevatorGuardWarningLabel-11-682567-000.........................................................................13
Electrical Overview ................................................................................................................14ElectricalSubpanelSpecifications..................................................................................................14PinsetterSubpanelandSurgeSuppressorInstallation....................................................................16SelectingaSurgeSuppressor..........................................................................................................17
Electrical Specifications .........................................................................................................18ImportantWiringInstructions.........................................................................................................18OperatingVoltages/PowerConnections........................................................................................19GSNexgen(WithoutSafetyController)......................................................................................19GSNexgen(WithSafetyController)...........................................................................................21
Power Outlet Information .....................................................................................................25SummaryofElectricalInformation................................................................................................25GSPinsetterPowerOutletInformation.........................................................................................26BaseGuardingwithoutSafetyController-CurtainWall/MaskingUnit..................................26BaseGuardingwithoutSafetyController-MaskingWall.........................................................27
SafetyControllerPowerOutletInformation...................................................................................28AdvancedGuardingwithSafetyController-CurtainWall/MaskingUnit................................28AdvancedGuardingwithSafetyController-MaskingWall.......................................................29
BallLiftControlBoxPowerOutletInformation...........................................................................30Tel-E-FoulPowerOutletInformation............................................................................................31Lanemachinepoweroutletinformation.........................................................................................32Ballpolisherpoweroutletinformation...........................................................................................33LightworxPowerOutletInformation..............................................................................................34PinballWizardPowerOutletInformation.......................................................................................35
8 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
IntroductionThisdocumentcontainstheinformationnecessaryforthepreparationofasiteconformingtoBrunswickspecifications.Itisveryimportantthesitecomplieswiththerequirementsspecifiedinthefollowingpages.Anydeviationsfromthesespecificationscouldcauseproblemstoyourequipmentthatmaybedifficulttodetectand/orcorrect.
Thisdocumentisdividedintothreesections.Refertotheparticularsectionneededfordetailsabouttheequipmentbeinginstalled.
• Introduction • ElectricalSpecifications • PowerOutletInformation
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 9
intERfEREnCE infoRmation
CAUTION! This equipment generates, uses, and can radiate radio frequency energy and if
not installed and used in accordance with the installation manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference.
nEC 250-74 Exception no. 4Whererequired,forthereductionofelectricalnoise(electromagneticinterference)onthegroundingcircuit,areceptacleinwhichthegroundingterminalispurposelyinsulatedfromthereceptaclemountingmeansshallbepermitted.Thereceptaclegroundingterminalshallbegroundedbyaninsulatedequipmentgroundingconductorrunwiththecircuitconductors.
ThegroundingconductorshallbepermittedtopassthroughoneormorepanelboardswithoutconnectiontothepanelboardgroundingterminalaspermittedbySection384-27,Exception,soastoterminatedirectlyattheapplicablederivedsystemorservicegroundingterminal.
Surge SuppressionATransientvoltagesuppressor(TVSS)issuppliedwiththepinsettersystem.Theinstallationofthisdeviceistheresponsibilityofthecustomerthroughalicensedelectrician.Theunitwillbelocatedatthepinsettersub-panelthatsuppliesthepowertothepinsetters.Thisunitisdesignedforthemostdemandingenvironmentandincorporatesmultistagefiltrationinitsdesign.TheSineWavetrackingseriesisengineeredtoremovethemorecomplexdisturbancesfoundintheelectricalenvironment,inparticular,highandlowvoltageringingtransientsandharmonicactivity.
NOTE: The surge suppressor wires should be as short as possible, with no coiling when installed on the pinsetter sub-panel. The TVSS device is provided with a plastic coupler to insulate the unit from the sub-panel.
10 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
SafEty WaRninG LabELS
Warning Label Location - 11-682565-000
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 11
ELEvatoR WaRninG LabELS
Elevator Guard Warning Label - 11-682498-000
12 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Elevator Guard Warning Label - 11-682566-000
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 13
Elevator Guard Warning Label - 11-682567-000
14 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Electrical OverviewELECtRiCaL SubPanEL SPECifiCationS
IMPORTANT!: All subpanels and wiring MUST comply with local and national electrical codes.
Pinsetter Subpanel –ThePinsettersubpanelusedtopowertheGS-SeriespinsettersandotherBrunswickequipmentmustbepowereddirectlyfromtheprimarymainservicesubpanelortransformerandmustbethreephase.Non-Brunswickequipmentincludingelectronicvideogames,arcwelders,HVAC,compressors,etc.,cannotsharethissub-panel.
Scoring Subpanel (Isolated Ground) –Thescoringsubpanelmustbepoweredfromthemainservicesubpanelortransformer.ThisisanisolatedgroundsubpanelthatisREQUIREDforallofBrunswickelectronicequipmentandinstalledaccordingtoNationalElectricCode250-74orsimilarisolatedgroundguidelinesaccordingtolocalcodeandnationalelectriccodes.Alltheoutletsforthispanelmustbeanisolatedreceptaclesimilarto“HubbellIG5262”receptacles.
TheONLYtypeofequipmenttobeinstalledinthesubpanels:
Pinsetter Subpanel
• GS-XPinsetter
• BallLift
• Tel-E-Foul
• LaneMachine
• BallPolisher
• Lightworx
• LanescapeVideoMaskingUnit
Scoring Subpanel (Isolated Ground) • ScoringComputer
• OverheadMonitors
• DisplayController
• HDVideoDistributionCenter
• ServerComputer
• ClientComputer
• Automated-PinballWizard
WARNING! Any Non-Brunswick equipment circuits located in these subpanels will VOID ALL WARRANTY. This includes electronic video games, arc welders, HVAC, compressors, etc.
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 15
IMPORTANT!: Split house centers with multiple subpanels require a single source of power and ground from main service.
16 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
PinSEttER SubPanEL and SuRGE SuPPRESSoR inStaLLation
CAUTION! Each phase from the surge suppressor should be installed on each phase of power on the 3 phase circuit breaker, typically pinsetter 1 and 2 circuit breaker.
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 17
SELECtinG a SuRGE SuPPRESSoRAflowchartdiagramisshownbelowtoassistyouinidentifyingwhichsurgesuppressorisneeded.
Model Voltage/Phase Wye/Delta No. of Wires Brunswick Part No. TK-TT100-3Y208-F 120/208Three Wye 4Wire+Ground 47-862103-000 TK-TT100-3D240-F 120/240Three Delta 4Wire+Ground 47-862105-000 TK-TT100-3Y380-F 220/380Three Wye 4Wire+Ground 47-862104-000
STARTHERE
ARE YOU SURE THEI.G. SUB-PANEL HAS
THREE PHASE(HOT) CONDUCTORS?
YES
IS THERE A NEUTRALCONDUCTOR?
YES
IF YOU MEASURE THEINDIVIDUAL VOLTAGESBETWEEN PHASE AND
NEUTRAL ARE THEYALL THE SAME?
STARTOVER
NO
NO YES
IS ONE PHASE TONEUTRAL VOLTAGEHIGHER THAN THE
OTHER TWO?
YES
SELECTTK-TT100-3D240-F
(47-862105-000)
IS THE PHASETO NEUTRAL
VOLTAGE 120?NO
YES
IS IT 220 VOLT?
NO
STARTOVER
YES
SELECTTK-TT100-3Y208-F
(47-862103-000)
SELECTTK-TT100-3Y380-F
(47-862104-000)
18 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Electrical SpecificationsimPoRtant WiRinG inStRuCtionS 1. TheGS-Seriessub-panelusedtopowertheGS-SeriespinsettersorBrunswickequipmentmust
bepowereddirectlyfromtheprimaryservicepanelortransformerandmustbethreephase.
2. NocircuitstotheGS-Seriessub-panelcanshareaconduitwithothernon-Brunswickequipment.
3. UsecorrectAWGforsub-panelandassociatedbranchcircuits.Ifsub-paneltomainservice(feed)exceeds150feet(45.72m),increasetheAWGofwireaccordingly.
4. Non-Brunswickequipmentincludingelectronicvideogames,arcwelders,etc.,cannotsharethissub-panel.
5. Iflocalcoderequiresconduit,raceways,orotherdevicesforwiringto,from,orbetweenBrunswickequipment,theinstallationandmaterialcostsshallbetheresponsibilityofthecustomer.
6. Allwiringandsub-panelsmustbefurnishedandinstalledbythecustomer.
7. AllpowerdistributionandwiringMUSTcomplywithlocalandnationalelectricalcodes.
8. Failuretocomplywiththeseinstructionswillvoidallwarrantiesduetoelectricalnoiseorwherepowerconditioningisneeded.
9. Wiringofsurgesuppressorneedstobeonthesamecircuitbreakeraslanes1and2.
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 19
oPERatinG voLtaGES / PoWER ConnECtionS
GS nexgen (Without Safety Controller)ThemotorontheGS-Seriesmachinecanbewiredforeither208phasetophaseor240phasetophase,380phasetophasevoltage.
ShownbelowarethreeconfigurationsofinputpowertotheGS-SeriespinsettersthatareNOTequippedwithSafetyControllers;Figure 1isfora120/240volt(Delta)3phasesystem,Figure 2isfora208volt(Wye)3phasesystem,Figure 3isfora220/380volt(Wye)3phasesystem.andFigure 4Isfora220volt(PhaseConverterwithoutaSafetyController)3phasesystem,
Figure 1
Figure 2
20 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Figure 3
Figure 4
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 21
GS nexgen (With Safety Controller)ShownbelowarethreeconfigurationsofinputpowertotheGS-SafetyController;Figure 5isfora120/240volt(Delta)3phasesystem,Figure 6isfora208volt(Wye)3phasesystem,Figure 7isfora220/380volt(Wye)3phasesystem,Figure 8isfor220voltsinglephasewithphaseconverter(residential)andFigure 9isfor220voltsinglewithphaseconverterwithaBuck/Boosttransformerusedtolowerthevoltageonthegeneratedphase(residential).
Figure 5
22 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Figure 6
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 23
Figure 7
24 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
Figure 8
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 25
Power Outlet InformationSummaRy of ELECtRiCaL infoRmation
REAR OF CURTAIN WALL ALL WIRING FOR 120-230 VOLTS MUST BEFURNISHED AND INSTALLED BY CUSTOMER.
ALL WIRING MUST CONFORM TO LOCAL CODES.
5' 8" (1727 mm)
5' 8" (1727 mm)
NOTE : DIMENSIONS ARE BASED ON THE USE OF 10-1/2"(267 mm) WIDE BALL RETURNS
RETURN
DIVISION
APPROACH
FOUL LINE
16' 1-5/16" (4910 mm)DOES NOT INCLUDE
FOUL LINE
P
P
153"(3887 mm)
LENGTH OF BOWLING INSTALLATION (LESS REAR AISLE)A-2 83' 2" (25349 mm)
GS-SERIES 83' 5-1/16" (25427 mm)
CLCL
11' 1-1/4"(3385 mm)
11' 1-1/4"(3385 mm)
G
G
G T
BL
BL
BL
LM
LM
PBW
PBW
PBW
L
BP
CONCOURSEBOWLER’S AREA
S
S
S
2'(610 mm)
S
S
G
G
PBW
PBW
CL
TL
TL
26 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
GS PinSEttER PoWER outLEt infoRmation
base Guarding without Safety Controller - Curtain Wall / masking unit PowEr rEquirEmEnts - Gs sEriEs nExGEn ControllEr
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit rEquirEmEnt
CustomEr rEsPonsiBilitY
BrunswiCKrEsPonsiBilitY
RefeR to
figuRes1-4
50/60 AC 3 12 -3 oR 4 wiRe + insulAted
gRound
to supply feedeR wiRing, “J” box, flexible dRop
CoRd And mAting plugs.
to pRovide RequiRed AdApteR
CAble
CirCuit rEquirEmEnts - Gs-sEriEs nExGEn ControllEr
Gs-sEriEs suBPAnEl
wirEs PEr CirCuit units PEr CirCuit wirE
siZEBrEAKEr
siZE
rECEPtAClE ProViDED BY
CustomEryes 3/4 1 peR lAne pAiR 12 gAuge 15 A yes
outlEt loCAtion - Gs-sEriEs nExGEn ControllEr
one JunCtion box Above the bAll RetuRn peR pAiR of gs pinsetteRs
CURTAIN WALL(BY CUSTOMER)
DROP CORD(BY CUSTOMER)
TYPE "S" SERVICE CORD,RUBBER SHEATHED,3 OR 4 CONDUCTOR,+ GROUND 12 GAUGE
70’ 6” (21488 mm) FROM 17-1/2” ± 1/4” (445 mm ± 6 mm) STEP
TO FRONT OF CURTAIN WALL
NEXGENCONTROL
BOX
ELECTRICAL JUNCTION BOX (BY CUSTOMER)208/230/380VAC, 50/60 HZ, 3 PHASE
LOCATION FOR WORLDWIDEEXCEPT EUROPE
66”(1676 mm)
30”(762 mm)
LANE SURFACE
FRONT VIEW OF ODD LANE PINSETTERONE DROP PER PAIR OF PINSETTERS
40"(1016 mm)
17”(432 mm)
TYPICAL PINSETTER POWER CONNECTIONS
ARE SHOWN.ALL ELECTRICAL CONNECTIONS
MUST COMPLY WITH THE CODE OF
THE AREA IN WHICH THE PINSETTERS
ARE BEING INSTALLED.
JUNCTION BOX
BALLRETURN
30”(762) m)
CL
SU
PP
LIE
D B
YC
US
TO
ME
R/E
LE
CT
RIC
IAN
ELECTRICIAN SUPPLIEDMALE/FEMALE
"S" TYPERUBBER SHEATHED3 OR 4 CONDUCTOR
+ GROUND12 GAUGE
(IF LOCAL CODES PERMIT)
DETAIL "A"(4 or 5 Conductor)
NEXGENCONTROL
BOX
ADAPTER CABLE
SUPPLIED BYBRUNSWICK
LEMAL15-20P
LEMAL15-20R
JUNCTION BOX TO BE CEILING MOUNTED30" (762 mm) LEFT OF BALL RETURN CENTER LINE
WITH CURTAIN WALL / MASKING UNIT
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 27
base Guarding without Safety Controller - masking Wall PowEr rEquirEmEnts - Gs sEriEs nExGEn ControllEr
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit rEquirEmEnt
CustomEr rEsPonsiBilitY
BrunswiCKrEsPonsiBilitY
RefeR to
figuRes1-4
50/60 AC 3 12 -3 oR 4 wiRe + insulAted
gRound
to supply feedeR wiRing, “J” box, flexible dRop
CoRd And mAting plugs.
to pRovide RequiRed AdApteR
CAble
CirCuit rEquirEmEnts - Gs-sEriEs nExGEn ControllEr
Gs-sEriEs suBPAnEl
wirEs PEr CirCuit units PEr CirCuit wirE
siZEBrEAKEr
siZE
rECEPtAClE ProViDED BY
CustomEryes 3/4 1 peR lAne pAiR 12 gAuge 15 A yes
outlEt loCAtion - Gs-sEriEs nExGEn ControllEr
one JunCtion box Above the bAll RetuRn peR pAiR of gs pinsetteRs
CURTAIN WALL(BY CUSTOMER)
DROP CORD(BY CUSTOMER)
TYPE "S" SERVICE CORD,RUBBER SHEATHED,3 OR 4 CONDUCTOR,+ GROUND 12 GAUGE
70’ (21336 mm) FROM 17-1/2” ± 1/4” (445 mm ± 6 mm) STEP
TO BACK OF MASKING WALL
NEXGENCONTROL
BOX
ELECTRICAL JUNCTION BOX (BY CUSTOMER)208/230/380VAC, 50/60 HZ, 3 PHASE
LOCATION FOR WORLDWIDEEXCEPT EUROPE
22”(559 mm)
40”(1016 mm)
LANE SURFACE
FRONT VIEW OF ODD LANE PINSETTERONE DROP PER PAIR OF PINSETTERS
40"(1016 mm)
17”(432 mm)
TYPICAL PINSETTER POWER CONNECTIONS
ARE SHOWN.ALL ELECTRICAL CONNECTIONS
MUST COMPLY WITH THE CODE OF
THE AREA IN WHICH THE PINSETTERS
ARE BEING INSTALLED.
JUNCTION BOX
BALLRETURN
30”(762) m)
CL
SU
PP
LIE
D B
YC
US
TO
ME
R/E
LE
CT
RIC
IAN
ELECTRICIAN SUPPLIEDMALE/FEMALE
"S" TYPERUBBER SHEATHED3 OR 4 CONDUCTOR
+ GROUND12 GAUGE
(IF LOCAL CODES PERMIT)
DETAIL "A"(4 or 5 Conductor)
NEXGENCONTROL
BOX
ADAPTER CABLE
SUPPLIED BYBRUNSWICK
LEMAL15-20P
LEMAL15-20R
JUNCTION BOX TO BE CEILING MOUNTED30" (762 mm) LEFT OF BALL RETURN CENTER LINE
WITH MASKING WALL
IMPORTANT!MASKING WALL MUST BE CONSTRUCTEDAFTER PINSETTERS ARE INSTALLED.
28 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
SafEty ContRoLLER PoWER outLEt infoRmation
advanced Guarding with Safety Controller - Curtain Wall / masking unitPowEr rEquirEmEnts - Gs sEriEs sAfEtY ControllEr
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit rEquirEmEnt
CustomEr rEsPonsiBilitY
BrunswiCKrEsPonsiBilitY
RefeR to
figuRes 5-8
50/60 AC 3 12 -3 oR 4 wiRe + insulAted
gRound
to supply feedeR wiRing, “J” box, flexible dRop
CoRd And mAting plugs.
-
CirCuit rEquirEmEnts - Gs-sEriEs sAfEtY ControllEr
Gs-sEriEs suBPAnEl
wirEs PEr CirCuit units PEr CirCuit wirE
siZEBrEAKEr
siZE
rECEPtAClE ProViDED BY
CustomEryes 3/4 1 peR lAne pAiR 12 gAuge 15 A yes
outlEt loCAtion - Gs-sEriEs sAfEtY ControllEr
one JunCtion box Above odd lAne elevAtoR peR pAiR of gs pinsetteRs.
ELECTRICAL JUNCTION BOX (BY CUSTOMER)208/230/380VAC, 50/60 HZ, 3 PHASE
DROP CORD(BY CUSTOMER)
TYPE "S" SERVICE CORD,RUBBER SHEATHED,3 OR 4 CONDUCTOR,
+ INSULATED GROUND12 GAUGE
SAFETYCONTROLLER BOX
12’ 2” (3708 mm)TO CURTAIN WALL
i NOTE: POWER TO NEXGEN CONTROLLER SUPPLIED BY GS-SERIES SAFETY CONTROLLER
REAR VIEW OF ODD LANE PINSETTERONE DROP PER PAIR OF PINSETTERS
ELECTRICIAN TO HARDWIRE
POWER CABLEINTO SAFETY
CONTROLLER BOX.ALL ELECTRICAL CONNECTIONS
MUST COMPLY WITH THE CODE OF
THE AREA IN WHICH THE PINSETTERS
ARE BEING INSTALLED.
JUNCTION BOX
BALLRETURN
49”(1245 mm)
CL
SU
PP
LIE
D B
YC
US
TO
ME
R/E
LE
CT
RIC
IAN
"S" TYPERUBBER SHEATHED3 OR 4 CONDUCTOR
+ INSULATED GROUND 12 GAUGE
(IF LOCAL CODESPERMIT)
DETAIL "A"(3 or 4 Conductor + Insulated Ground)
SAFETYCONTROLLER
BOX
S
S
WITH CURTAIN WALL / MASKING UNIT
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 29
advanced Guarding with Safety Controller - masking WallPowEr rEquirEmEnts - Gs sEriEs sAfEtY ControllEr
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit rEquirEmEnt
CustomEr rEsPonsiBilitY
BrunswiCKrEsPonsiBilitY
RefeR to
figuRes 5-8
50/60 AC 3 12 -3 oR 4 wiRe + insulAted
gRound
to supply feedeR wiRing, “J” box, flexible dRop
CoRd And mAting plugs.
-
CirCuit rEquirEmEnts - Gs-sEriEs sAfEtY ControllEr
Gs-sEriEs suBPAnEl
wirEs PEr CirCuit units PEr CirCuit wirE
siZEBrEAKEr
siZE
rECEPtAClE ProViDED BY
CustomEryes 3/4 1 peR lAne pAiR 12 gAuge 15 A yes
outlEt loCAtion - Gs-sEriEs sAfEtY ControllEr
one JunCtion box Above odd lAne elevAtoR peR pAiR of gs pinsetteRs.
ELECTRICAL JUNCTION BOX (BY CUSTOMER)208/230/380VAC, 50/60 HZ, 3 PHASE
DROP CORD(BY CUSTOMER)
TYPE "S" SERVICE CORD,RUBBER SHEATHED,3 OR 4 CONDUCTOR,
+ INSULATED GROUND12 GAUGE
SAFETYCONTROLLER BOX
13’ (3962 mm)TO MASKING WALL
i NOTE: POWER TO NEXGEN CONTROLLER SUPPLIED BY GS-SERIES SAFETY CONTROLLER
REAR VIEW OF ODD LANE PINSETTERONE DROP PER PAIR OF PINSETTERS
ELECTRICIAN TO HARDWIRE
POWER CABLEINTO SAFETY
CONTROLLER BOX.ALL ELECTRICAL CONNECTIONS
MUST COMPLY WITH THE CODE OF
THE AREA IN WHICH THE PINSETTERS
ARE BEING INSTALLED.
JUNCTION BOX
BALLRETURN
49”(1245 mm)
CL
SU
PP
LIE
D B
YC
US
TO
ME
R/E
LE
CT
RIC
IAN
"S" TYPERUBBER SHEATHED3 OR 4 CONDUCTOR
+ INSULATED GROUND 12 GAUGE
(IF LOCAL CODESPERMIT)
DETAIL "A"(3 or 4 Conductor + Insulated Ground)
SAFETYCONTROLLER
BOX
S
S
WITH MASKING WALL
30 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
baLL Lift ContRoL box PoWER outLEt infoRmation PowEr rEquirEmEnts - BAll lift Control Box
Volts HErtZ AC/DC PHAsE H.P.
motor AmP CirCuit rEquirEmEnt
CustomEr rEsPonsiBilitY
BrunswiCKrEsPonsiBilitY
120 208 230
50/60 AC 1 1/46A @ 1204A @ 208 oR 230
3 wiRe insulAted
withgRound
to supply feedeR wiRing And “J”
box, CustomeR/eleCtRiCiAn
ConneCt
supply flexible poweR wiRing
with mAle plug, JunCtion box &
CAble
CirCuit rEquirEmEnts - BAll lift Control Box
wirEs PEr CirCuit units PEr CirCuit wirE siZE BrEAKEr siZE rECEPtAClE ProViDED BY CustomEr
3 2 12 gAuge 20A 120v/16A 230v no
outlEt loCAtion - Gs - BAll lift Control Box
one JunCtion box undeR the AppRoACh At eACh bAll RetuRn.
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 31
tEL-E-fouL PoWER outLEt infoRmation PowEr rEquirEmEnts - tEl-E-foul
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit
rEquirEmEntCustomEr
rEsPonsiBilitYBrunswiCK
rEsPonsiBilitY
120 /230 50/60 AC 1 1 [email protected]@230
3 wiRe insulAted with
gRound
to supply feedeR wiRing And “J” box And low voltAge
ContRol CustomeR/eleCtRiCiAn
ConneCt
to supply And instAll
tel-e-foul And poweR CAble to
“J” box.
CirCuit rEquirEmEnts - tEl-E-foul
wirEs PEr CirCuit units PEr CirCuit wirE siZE BrEAKEr siZE rECEPtAClE ProViDED BY CustomEr
3 14 12 gAuge 20 A yes
3 20 12 gAuge 16A yes
outlEt loCAtion - Gs - BAll lift Control Box
one JunCtion box below the tel-e-foul units on eACh RetuRn neAR the foul line.
notE: tel-e-fouls switChed by 2 lAnes At ContRol desk (supplied And instAlled by CustomeR).
REAR OF CURTAIN WALL ALL WIRING FOR 120-230 VOLTS MUST BEFURNISHED AND INSTALLED BY CUSTOMER.
ALL WIRING MUST CONFORM TO LOCAL CODES.
5' 8" (1727 mm)
5' 8" (1727 mm)
NOTE : DIMENSIONS ARE BASED ON THE USE OF 10-1/2"(267 mm) WIDE BALL RETURNS
RETURN
DIVISION
APPROACH
FOUL LINE
16' 1-5/16" (4910 mm)DOES NOT INCLUDE
FOUL LINE
P
P
153"(3887 mm)
LENGTH OF BOWLING INSTALLATION (LESS REAR AISLE)A-2 83' 2" (25349 mm)
GS-SERIES 83' 5-1/16" (25427 mm)
CLCL
11' 1-1/4"(3385 mm)
11' 1-1/4"(3385 mm)
G
G
G T
BL
BL
BL
LM
LM
PBW
PBW
PBW
L
BP
CONCOURSEBOWLER’S AREA
S
S
S
2'(610 mm)
S
S
G
G
PBW
PBW
CL
TL
TL
32 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
LanE maChinE PoWER outLEt infoRmation PowEr rEquirEmEnts - lAnE mACHinE
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit
rEquirEmEntCustomEr
rEsPonsiBilitYBrunswiCK
rEsPonsiBilitY
120 /230 50/60 AC 1 15 @ 12010@230 1080
3 wiRe insulAted
withgRound
to supply feedeR wiRing And “J”
box And 3-pRong gRounded outlet.
none
CirCuit rEquirEmEnts - lAnE mACHinE
VoltAGE wirEs PEr CirCuit units PEr CirCuit wirE siZE BrEAKEr siZE rECEPtAClE ProViDED BY
CustomEr
120 3 1 12 gAuge 20 A yes
230 3 1 12 gAuge 15 A yes
outlEt loCAtion - lAnE mACHinE
one JunCtion box At eveRy otheR bAll RetuRn inside the bAll RetuRn tRAp dooR.
REAR OF CURTAIN WALL ALL WIRING FOR 120-230 VOLTS MUST BEFURNISHED AND INSTALLED BY CUSTOMER.
ALL WIRING MUST CONFORM TO LOCAL CODES.
5' 8" (1727 mm)
5' 8" (1727 mm)
NOTE : DIMENSIONS ARE BASED ON THE USE OF 10-1/2"(267 mm) WIDE BALL RETURNS
RETURN
DIVISION
APPROACH
FOUL LINE
16' 1-5/16" (4910 mm)DOES NOT INCLUDE
FOUL LINE
P
P
153"(3887 mm)
LENGTH OF BOWLING INSTALLATION (LESS REAR AISLE)A-2 83' 2" (25349 mm)
GS-SERIES 83' 5-1/16" (25427 mm)
CLCL
11' 1-1/4"(3385 mm)
11' 1-1/4"(3385 mm)
G
G
G T
BL
BL
BL
LM
LM
PBW
PBW
PBW
L
BP
CONCOURSEBOWLER’S AREA
S
S
S
2'(610 mm)
S
S
G
G
PBW
PBW
CL
TL
TL
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 33
baLL PoLiShER PoWER outLEt infoRmation PowEr rEquirEmEnts - lAnE mACHinE
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit
rEquirEmEntCustomEr
rEsPonsiBilitYBrunswiCK
rEsPonsiBilitY
120 /230 50/60 AC 130 mAx
ondemAnd
1500to
2000
20 Amp,3 wiRe,
gRoundedoutlet
to supply An instAll outlet At desiRed loCAtion
in ConCouRse AReA.
none
CirCuit rEquirEmEnts - lAnE mACHinE
wirEs PEr CirCuit units PEr CirCuit wirE siZE BrEAKEr siZE rECEPtAClE ProViDED BY CustomEr
3 - 10 gAuge 30 A yes
outlEt loCAtion - lAnE mACHinE
one JunCtion box At desiRed ConCouRse loCAtion.
34 GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements
LiGhtWoRx PoWER outLEt infoRmation PowEr rEquirEmEnts - liGHtworx
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit
rEquirEmEntCustomEr
rEsPonsiBilitYBrunswiCK
rEsPonsiBilitY
120 /230 50/60 AC 1 [email protected]@230 120
3 wiRe insulAted
gRoundwith
ReCeptACle
to supply feedeR wiRing And “J” box And low
voltAge ContRol CustomeR/
eleCtRiCiAn to ConneCt.
to supply poweR CAble to
“J” box
CirCuit rEquirEmEnts - liGHtworx
wirEs PEr CirCuit units PEr CirCuit wirE siZE BrEAKEr siZE rECEPtAClE ProViDED BY CustomEr
3 14 12 gAuge 20 A yes
3 20 12 gAuge 16A yes
outlEt loCAtion - liGHtworx
one JunCtion box below the tel-e-foul units on eACh RetuRn neAR the foul line.
REAR OF CURTAIN WALL ALL WIRING FOR 120-230 VOLTS MUST BEFURNISHED AND INSTALLED BY CUSTOMER.
ALL WIRING MUST CONFORM TO LOCAL CODES.
5' 8" (1727 mm)
5' 8" (1727 mm)
NOTE : DIMENSIONS ARE BASED ON THE USE OF 10-1/2"(267 mm) WIDE BALL RETURNS
RETURN
DIVISION
APPROACH
FOUL LINE
16' 1-5/16" (4910 mm)DOES NOT INCLUDE
FOUL LINE
P
P
153"(3887 mm)
LENGTH OF BOWLING INSTALLATION (LESS REAR AISLE)A-2 83' 2" (25349 mm)
GS-SERIES 83' 5-1/16" (25427 mm)
CLCL
11' 1-1/4"(3385 mm)
11' 1-1/4"(3385 mm)
G
G
G T
BL
BL
BL
LM
LM
PBW
PBW
PBW
L
BP
CONCOURSEBOWLER’S AREA
S
S
S
2'(610 mm)
S
S
G
G
PBW
PBW
CL
TL
TL
GS-Series Pinsetters and Associated Bowling Equipment Electrical Requirements 35
PinbaLL WizaRd PoWER outLEt infoRmation PowEr rEquirEmEnts - PinBAll wiZArD
Volts HErtZ AC/DC PHAsE AmP wAtts CirCuit
rEquirEmEntCustomEr
rEsPonsiBilitYBrunswiCK
rEsPonsiBilitY
120 /230 50/60 AC 1
3 @120v2 @ 230 vpeR lAne
pAiR
-
2 wiRe + insulAted
gRoundwith i.g. 5262
hubbell ReCeptACle
oR equivAlent
to supply feedeR wiRing And “J” box with 120-230 volt i.g. 5262 hubbell ReCeptACle oR
equivAlent
to supply And instAll pinbAll
wizARd And poweR CAble to
“J” box
CirCuit rEquirEmEnts - PinBAll wiZArD
wirEs PEr CirCuit units PEr CirCuit wirE siZE BrEAKEr siZE rECEPtAClE ProViDED BY CustomEr
3 lAne pAiR 12 gAuge 20 A yes
3 lAne pAiR 12 gAuge 16 A yes
outlEt loCAtion - PinBAll wiZArD
one JunCtion box below gutteR , neAR eACh RetuRn 27’ (± 6’) fRom foul line.
± 6’ (1829 mm)
27’(8230 mm)
FOUL LINE
PBW