Pre-finished - ca.miele.ca · Pre-finished 36” MasterCool II K 2901 SF* / K 2911 SF* F 2901 SF* /...

6
Pre-finished 36” MasterCool II K 2901 SF* / K 2911 SF* F 2901 SF* / F 2911 SF* KF 2901 SF / KF 2911 SF KF 2981 SF 8miele.ca Specification Sheets TRS 04252019 Shown: KF 2981 SF Please note: This information is subject to change *The following models are not available in Canada : K 2901 SF, K 2911 SF, F 2901 SF & F 2911 SF

Transcript of Pre-finished - ca.miele.ca · Pre-finished 36” MasterCool II K 2901 SF* / K 2911 SF* F 2901 SF* /...

Pre-finished36” MasterCool II

K 2901 SF* / K 2911 SF*

F 2901 SF* / F 2911 SF*

KF 2901 SF / KF 2911 SF

KF 2981 SF

8miele.caSpecification Sheets TRS 04252019

Shown: KF 2981 SFPlease note: This information is subject to change*The following models are not available in Canada : K 2901 SF, K 2911 SF, F 2901 SF & F 2911 SF

DRAFT

Pre-finished 36” MasterCool II

Please note the following:• This specification sheet is for a single built-in unit.• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet. *If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.

SPECIFICATIONS

Overall Unit Dimensions 353/4” (908 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Excludes Fascia Dimension]

Overall Fascia Dimensions 361/2” (927 mm) W x 84”- 8511/16” (2134 - 2175 mm) H x 11/2” (32 mm) D

Niche

Minimum Cabinet Niche Opening 36” (915 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 24” (610 mm) D

Interior Volume K 29x1 SF F 29x1 SF KF 29x1 SF

Refrigeration Volume ** 0 **

Freezer Volume 0 ** *

Electrical K 29x1 SF F 29x1 SF KF 29x1 SF

Electrical Requirements110V / 120V, 60Hz, 15 Amps

In the case of side-by-side installations, a separate outlet must be used for each appliance.

Power Cord NEMA 5-15 plug, 5 ft (1.52 m)

Plumbing K 29x1 SF F 29x1 SF KF 29x1 SF

Water Supply Requirements -

Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pres-sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.

Water Connection Line - Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.

Shipping K 29x1 SF F 29x1 SF KF 29x1 SF

Shipping Weight 483 lbs (219 kg) 495 lbs (225 kg) 588 lbs (267 kg)

Shipping Dimensions 40” (1016 mm) W x 8913/16” (1,294 mm) H x 291/4” (800 mm) D

Support

Call Miele (800) 565-6435

Miele Website 8www.miele.ca

20/20 Link 82020technologies.com

K 2901 SF (Right Hinged)

K 2911 SF (Left Hinged)

F 2901 SF (Right Hinged)

F 2911 SF (Left Hinged)

KF 2901 SF (Right Hinged)

KF 2911 SF (Left Hinged)

Page 2 of 6

KF 2981 SF (French Door)

CUTOUT DIMENSIONS

Pre-finished 36” MasterCool II

CUTOUT DETAILS

• The electrical connection must not be positioned higher than 9” (228.6 mm) above the floor.

• The 1/4” (6.4 mm) plumbed water connection should not be positioned higher than 2” (50.8 mm) above the floor.

Notes:In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.

Page 3 of 6

SF frame

9/32”(7)

3/4”(19) Stainless steel door

Niche/Cabinetry

Please note unit’s outer SF frame.Top view:

POWER SUPPLY AND WATER CONNECTION(Water Connection For F 29x1 SF & KF 29x1 SF Only)

Pre-finished 36” MasterCool II

Water connection is located in front of unit.1/4” compression fitting is needed.

Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp - NEMA 5-15 molded plugWater line - 1/4” flexible water line - not included

Rear View Front View

Electrical Connection

Side View

Page 4 of 6

HINGING DETAILS 115° OPENING

Pre-finished 36” MasterCool II

Available for the following models:• K 29x1 SF• F 29x1 SF• KF 29x1 SF

Page 5 of 6

3”(76.2mm)

1-3/4”(44.5mm)

1-3/8”(35mm

)1-1/6” (29.6m

m)

1/4”(6.4mm

)17/24” (18m

m)

2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)

3”(76.2mm)

1-3/4”(44.5mm)

1-3/8”(35mm

)1-1/6” (29.6m

m)

1/4”(6.4mm

)17/24” (18m

m)

2-1/24”(52mm)2-1/3” (59mm)2-5/8” (67mm)

0-3/4” (19 mm

)1” (25 m

m)

1-1/4” (32 mm

)1-1/2” (38 m

m)

1-3/4” (44 mm

)

1-1/2” (38 mm)

1-1/4” (32 mm)

1” (25 mm)

0-3/4” (19 mm)

0-1/8” (3 mm)

DOOR SWING AT 115° OPENING 11 3/4”(298 mm)

Max

HINGING DETAILS 90° OPENING

Specification Sheets TRS 04252019

Pre-finished 36” MasterCool II

Available for the following models:• K 29x1 SF• KF 29x1 SF

Page 6 of 6

7/16”(11 mm)

1-3/16”(30mm)

1-7/16”(36.5mm)

1-11/16”(43mm)

1-15/16”(49.2mm)

Handle or object that is NOT flush with Cabinet Front.

0-3/4” (19 mm

)1” (25 m

m)

1-1/4” (32 mm

)1-1/2” (38 m

m)

1-3/4” (44 mm

)2” (51 m

m)

0-3/4” (19 mm)

1” (25 mm)

1-1/4” (32 mm)

1-1/2” (38 mm)

0-1/8” (3 mm)

When installing hinge side next to an appliance or object that is within range of the door panel, limit the door opening angle to 90°. This is done by installing the banking pin as illustrated. Insert the banking pin through the holes and drive in with a hammer.

DOOR SWING AT 90° OPENING 7/16” (11 mm)

38 11

/16” (

982

mm

)