PRANAY REPORT

46
1 DFPCL TALOJA Maintanance and Case study of pumps REPORT ON IN-PLANT TRAINING AT DFPCL [5 th MAY – 30 th JUNE]

Transcript of PRANAY REPORT

Page 1: PRANAY REPORT

1

Maintanance and Case study of pumps

REPORT ON IN-PLANT TRAINING AT DFPCL

[5th MAY – 30th JUNE]

TOPIC OF PROJECT : MAINTANENCE AND CASE STUDY OF PUMPS IN IPA

DFPCL TALOJA

Page 2: PRANAY REPORT

2

Maintanance and Case study of pumps

PLANT

NAME OF TRAINEE :PRANAY PRAKASH

INSTITUTION : NATIONAL INSTITUTE OF TECHNOLOGY [NIT] , SURAT

(395007),GUJARAT, INDIA.

DEPARTMENT : MECHANICAL ENGG

[IIIrd Year].

DFPCL TALOJA

Page 3: PRANAY REPORT

3

Maintanance and Case study of pumps

ACKNOWLEDGEMENT

The internship opportunity i had with DFPCL was a great chance for learning and professional development. Therefore, I consider myself as very lucky individual as i was provided with an opportunity to be a part of it. I am also greatful for having a chance to meet so many wonderful people and professionals who led me though this internship period.

Bearing in mind , I am using this opportunity to express my deepest gratitude and special thanks to the MRS. Katkar ,MRS Rashmi Joshi and MR.Rai who in spite of being extraordinarily busy with their duties, took time out to hear, guide and keep me on the correct path and allowing me to carry out my project at their esteemed organization and extending during the training.

I express my deepest thanks to MR. Dakava,MR Ghughe,MR. Desai and all operators of respective machines for taking part in useful decision & giving necessary advices and guidance and arranged all facilities to make life easier at DFPCL. I choose this moment to acknowledge their contribution gratefully for their careful and precious guidance which were extremely valuable for my study both theoretically and practically.

I perceive this opportunity as a big milestone in my career development. I will strive to use gained skills and knowledge in the best possible way, and will continue to work on their improvement, in order to attain desired career objectives. Hope to continue cooperation with all of you in the future.

Sincerely,

PRANAY PRAKASH

MECHANICAL ENGG. [3rd YEAR]

NIT SURAT.

DFPCL TALOJA

Page 4: PRANAY REPORT

4

Maintanance and Case study of pumps

INDEX

SR NO.

TOPIC PAGE

1. COMPANY PROFILE 5

2. SAFETY MEASURES AT DFPCL 7

3. SAFETY INDUCTION 9

4. INTRODUCTION TO PETROCHEMICALS 10

5. ISOPROPYL AT A GLANCE 12

6. IPA PRODUCTION IN DFPCL 14

7. MAINTENANCE PHILOSOPHY 16

8. PUMPS INTRODUCTION AND ITS TYPES 18

9. PREVENTIVE MAINANACE OF PUMPS 20

10. TRUBLESHOOTING OF PUMPS 24

11. CASE STUDY ON 9101 A/B 26

12. EXAMINATION OF INDIVIDUAL COMPONENTS 28

13. CONCLUSION 31

14. RECOMMENDATION 32

15. REFERENCE 33

DFPCL TALOJA

Page 5: PRANAY REPORT

5

Maintanance and Case study of pumps

DFPCL (TALOJA WORKS)Background : Deepak Fertilisers And Petrochemicals Corporation Ltd (DFPCL) was established in 1979 as an Ammonia manufacturer. DFPCL commenced commercial production of ammonia in 1983 with a technical collaboration with Fish International Engineers, USA, using natural gas as feedstock. Later, during 1991, the company integrated forward into methanol and downstream products of ammonia-nitro phosphate fertilisers, technical ammonium nitrate and various grades of nitric acids, liquid carbon dioxide and hydrogen. In 2006, the company commenced the manufacture of Iso Propyl Alcohol. In 2005, the company forayed into realty through a distinctive Lifestyle Centre, Ishanya. The company forayed into the Indian and global fresh produce market with the acquisition of Desai Fruits and Vegetables in 2011. DFPCL has now grown to be a multiproduct, multi-customer conglomerate, agri products and services, fresh produce, petrochemicals and retail.

Business Operations: DFPCL is one of Asia’s largest single location manufacturers of nitric acid, India’s leading manufacturer of Iso Propyl Alcohol and amongst the largest manufacturers of technical ammonium nitrate in the world. With its plants located at Taloja, Mumbai, DFPCL operates through an extensive network of dealers, resellers and stockists across India, a network that is deep, widespread and formidable. DFPCL has two key subsidiaries viz. Smartchem Technologies Ltd. and Deepak Mining Services Pvt. Ltd.

Chemicals : During FY12, the chemicals segment contributed around 57% to the total revenue of the company. The industrial chemicals division caters to a cross-section of mining and industrial customers, both small and large. These include all the major companies across mining, pharmaceuticals, pesticides, resins, textiles, printing, packaging, petrochemicals, dyes, dyestuff and food sectors. The company has storage facilities at the plant in Taloja as well as at JNPT. As on March 31, 2012 the installed capacity for ammonia stood at 128,700 MTPA, TAN at 469,000 MTPA, CNA at 138,600 MTPA, DNA at 702,900, Methanol at 100,000 MTPA and that of IPA stood at 70,000 MTPA.

Agri Products & Services/Fertilisers : DFPCL is one of India’s largest and most reputed manufacturers of nitro phosphate fertilisers and speciality fertilisers like sulphur bentonite. During FY12, the agri sector contributed around 41% to the total revenue of the company. DFPCL has an installed capacity of 229,500 MTPA for nitro phosphate fertilisers and 25,000 MTPA of bensulf. The company manufactures 24:24:0 prilled NP fertilizer containing nitrogen in nitrate and ammoniacal forms as well as water soluble phosphates. The company also sells various grades of other fertilizers, both bulk and specialty, under two prominent brand umbrellas,

DFPCL TALOJA

Page 6: PRANAY REPORT

6

Maintanance and Case study of pumps

viz. Mahadhan and Bhoodan. Its brand strengths in the fertilizer markets that it caters to across Maharashtra, Karnataka, Gujarat, Punjab, Haryana, UP and MP are formidable. DFPCL operates through a two-tier marketing network. First, through its own dealership network comprising nearly 4,500 dealers and secondly, through institutional networks, such as sugar co-operatives, who in turn, sell its fertilizers to the farmers. Moreover, the company has entered into strategic tie-ups with various marketing federations, namely Fertilisers Co-operation of India and Duncans. DFPCL’s fertilisers are sold across Maharashtra, Karnataka, Gujarat, UP, MP, Punjab, Haryana and WB among others. DFPCL is the first company in India to provide total nutrient management services to the Indian farmers through its Mahadhan Saarrthie Centres, which bring agricultural production technologies to the door-step of

DFPCL is now focussed on global growth, drawing strengths from its existing product and plant synergies and adding new product lines, new plants and augmenting manufacturing capacities.

In Technical Ammonium Nitrate (TAN) it’s moving from a domestic market leader to being a global player, while moving further forward into Mining Services and Contract Mining

In Agri-business, DFPCL has moved from bulk fertilisers to specialties/customised products and farm solutions and further into produce management

In Chemicals, the Company is moving up the value chain from bulk chemical commodities to high-value petrochemicals

It has built India’s first true Lifestyle Centre, Ishanya, that re-creates a unique consumer experience that is part retail, part entertainment and part public space

Future Plans : DFPCL plans on further doubling the existing capacity at its integrated fertiliser complex at Taloja , Maharashtra with an investment of around ` 3.6 bn in the proposed project that will enhance the capacity of its NPK grades complex fertilisers from 229,000 MTPA to 600,000 MTPA. It will gain additional flexibility to produce all NP/NPK grades with fortification of micro-nutrients. The company is also coming up with a 32,000 MTPA greenfield new bentonite sulphur plant to be set up at a cost of ` 0.55 bn near Panipat, Haryana. Both projects are expected to be completed in a 30-months timeframe from commencement.

DFPCL TALOJA

Page 7: PRANAY REPORT

7

Maintanance and Case study of pumps

Safety Procedures/Measures at DFPCL

1. SHE (Safety,Health,Environment) Policy : Manufacturing of fertilisers and petrochemicals involves handling,processing and storage of no.of hazardous chemicals. SHE organisation to coordinate and monitor systems and it is manned by professionally qualified personnel.For safety barricades define and proper usage of colured tape :

“YELLOW”- Means caution .

“RED AND WHITE(RED)” - Means Danger.

“PYLONS” - Orange pylons can be used to designate

Parking spaces.

2. HOUSEKEEPING : Good skills are essential for personnel safety,reducing potential hazards and keeping work areas safe,clutter free,maintain walk ways,ensure office lighting is adequate,never walk on wet floors,no office shall be placed in hallways or exit ways.

3. MATERIAL STORAGE : No storage of materialsin aisles,corners or passage ways.Books should be kept on shelves or neatly stored.Heavy objects should be located on low shelving,no chemical storage in office areas. “Carpeting” should be in good condition to prevent trip hazards,secure electrical cords and wires away walkaways.

4. SAFETY PERMIT PROCEDURES : To ensure proper authorisation of non-routine work. To make clear to persons carrying out the job,the risks involved and precaution to be

taken. To ensure that person responsible for an area is aware of all work being done there. In DFPCL, Class I and Class II permits are followed. Jobs of high risk nature are included in Class I and of no risk are covered in Class II. Class I – Jobs involving use of open flame or spark,gas cutting,welding jobs,entering

into vessels and confined spaces, work at fragile roof tops,drilling of pipelines and equipment.

Class II – Jobs involving work on de energised systems,painting jobs,maintanence work,drilling on walls.

DFPCL TALOJA

Page 8: PRANAY REPORT

8

Maintanance and Case study of pumps

5. SAFETY IN MATERIAL HANDLING : Plan a route that is free from tripling and slipping hazards.Judge weight of load for sharp edges. Wear gloves,safety shoes.

(Before lifting , Lifting , Carrying , Unloading ).

Stand as close to load as possible. Grasp load firmly.

6. PERSONAL PROTECTIVE EQUIPMENT : Head protection(helmets). Hand and arm protection(gloves,PVC gloves). Foot protection(safety shoes). Body protection(rubber/pvc). Ear protection(ear plugs). Safety belts.

7. HOSES : Area shaft engg.is responsible to implement these practices. Use of hose is allowed only temporary for steam and air. A steam hose should be inspected for any visible physical defects. Check hose surfaces for blisters.cracks or cuts. Hose should not be placed across hot lines. Sharp bends should be avoided. Compressed air should not be used to blow air. Drain valve on air receiver should be opened periodically. Tight connections.

8. HAND TOOLS & POWER TOOLS : Select the proper tools. Check the tool before starting up the job. Wherever necessary use clamps or vice to secure jobs. Grinder should not be used for redressing the heat treated tools. Ensure proper earthing to power tools. Disconect power tools before adjusting or repair when they are not in use.

9. GRINDING WHEEL SAFE PRACTICES : Grinding wheel if breaks in running condition may cause serious even fatal accidents. Never use a whell that has any sign of a fracture. Holes on wheels should never be altered. Excessive tightening of mounting nut is dangerous. All guards should be in piston.

DFPCL TALOJA

Page 9: PRANAY REPORT

9

Maintanance and Case study of pumps

SAFETY INDUCTION AT DFPCL

The safety induction was presented to us by MR. Deshmukh at safety hall downsides plant building.During this induction of around 2 hrs.we were acquired with very useful knowledge regarding safety at chemical and fertilisers and their consequences if ignored or following wrong parametres of the same.The presentation was indeed an eye opener to us,as we weren’t aware about such importance given to safety in chemical factories to eliminate risk.

Following are the important parameters whivh must be considered to eliminate risk at every aspect during working at chemical/fertilisers plants :-

1. Elimination : This means that see and inpsect physically if you can eliminate a particular or in other words think if is necessary to do that kind of job. If not just try to

eliminate it.

2. Substitution : After you get clearance from above inspection and if the job or process appears risky,just sunstitute with a simpler and safer process requirement.

3. Engineering Design : This is one of the important factors which relates engineering knowledge with the safety concerns. Design the systems such that no accident can take place irrespective of conditions.

4. Administrative Control : Operators should strictly follow standard operating procedures[SOP] related to each process conditions. SOP are certified and checked by higher authorities and then forwaded to the operators for ease of understanding of process.

5. PPE : Personal-Protective-Equipment(or PPE’s) should be used wherever required. Eg include such as safety shoes,safety eye goggles,helmet .

In general, authorities tend to give a high stress on PPE;s, instead they need to manage the

Difference between hazard and risk in any process involved and apply the important

Procedures mentioned above to completely demolish risk involved in any job.

DFPCL TALOJA

Page 10: PRANAY REPORT

10

Maintanance and Case study of pumps

WHAT ARE PETROCHEMICALS?

Petrochemicals, also called petroleum distillates, are chemical products derived from petroleum petroleum are also obtained from other fossil fuels, such as coal or natural gas, or renewable sources such as corn or sugar cane.

The two most common petrochemical classes are olefins (including ethylene and propylene) and aromatics (including benzene, toluene and xylene isomers). Oil refineries produce olefins and aromatics by fluid catalytic cracking of petroleum fractions. Chemical plants produce olefins by steam cracking of natural gas liquids like ethane and propane. Aromatics are produced by catalytic reforming of naphtha. Olefins and aromatics are the building-blocks for a wide range of materials such as solvents, detergents, and adhesives. Olefins are the basis for polymers and oligomers used in plastics, resins, fibers, elastomers, lubricants, and gels.

Primary petrochemicals are divided into three groups depending on their chemical structure:

1. Olefins includes ethylene, propylene, and butadiene. Ethylene and propylene are important sources of industrial chemicals and plastics products. Butadiene is used in making synthetic rubber.

2. Aromatics includes benzene, toluene, and xylenes. Benzene is a raw material for dyes and synthetic detergents, and benzene and toluene for isocyanates MDI and TDI used in making polyurethanes. Manufacturers use xylenes to produce plastics and synthetic fibers.

3. Synthesis gas is a mixture of carbon monoxide and hydrogen used to make ammonia and methanol. Ammonia is used to make the fertilizer urea and methanol is used as a solvent and chemical intermediate.

Petrochemicals do not reach the final consumer - the man in the street; they are first sold to customer industries, undergo several transformations, and then go into products that seem to bear no relation whatsoever to the initial raw material. As a result, few of us make the connection between the petrochemical industry and their GP's equipment, their DVDs, food packaging or computers; few realise the amount of scientific efforts that went into these commonplace objects. Although benefiting daily from end products that have been made thanks to the input of the petrochemical industry, more often than not we see no obvious connection between these everyday commodities and petrochemistry.

DFPCL TALOJA

Page 11: PRANAY REPORT

11

Maintanance and Case study of pumps

Some of the petrochemical products used in our daily lives

A Petrochemical plant in Saudi-Arabia

DFPCL TALOJA

Page 12: PRANAY REPORT

12

Maintanance and Case study of pumps

ISOPROPYL AT A GLANCEIsopropyl alcohol (IUPAC name propan-2-ol), also called isopropanol or dimethyl carbinol, is a compound with the chemical formula C3H8O or C3H7OH or CH3CHOHCH3 (sometimes represented as i-PrOH). It is a colorless, flammable chemical compound with a strong odor. As a propyl group linked to a hydroxyl group, it is the simplest example of a secondary alcohol, where the alcohol carbon atom is attached to two other carbon atoms, sometimes shown as (CH3)2CHOH. It is a structural isomer of 1-propanol. It has a wide variety of industrial and household uses.

PROPERTIES:

Isopropyl alcohol is miscible in water, ethanol, ether, and chloroform. It will dissolve ethyl cellulose, polyvinyl butyral, many oils, alkaloids, gums and natural resins.It is insoluble in salt solutions.Unlike ethanol or methanol, isopropyl alcohol can be separated from aqueous solutions by adding a salt such as sodium chloride, sodium sulfate, or any of several other inorganic salts, since the alcohol is much less soluble in saline solutions than in salt-free water. The process is colloquially called salting out, and causes concentrated isopropyl alcohol to separate into a distinct layer.

Isopropyl alcohol forms an azeotrope with water, which gives a boiling point of 80.37 °C (176.67 °F) and a composition of 87.7 wt% (91 vol%) isopropyl alcohol. Water-isopropyl alcohol mixtures have depressed melting points.[6] It has a slightly bitter taste, and is not safe to drink. Isopropyl alcohol becomes increasingly viscous with decreasing temperature. At temperatures below −70 °C (−94 °F), isopropyl alcohol resembles maple syrup in viscosity. Isopropyl alcohol has a maximum absorbance at 205 nm in an ultraviolet-visible spectrum.

APPLICATIONS:

Solvent:-

Isopropyl alcohol dissolves a wide range of non-polar compounds. It also evaporates quickly, leaves nearly zero oil traces, compared to ethanol, and is relatively non-toxic, compared to alternative solvents. Thus, it is used widely as a solvent and as a cleaning fluid, especially for dissolving oils. Together with ethanol, n-butanol, and methanol, it belongs to the group of alcohol solvents, about 6.4 million tonnes of which were utilized worldwide in 2011. Examples of this application include cleaning electronic devices such as contact pins (like those on ROM cartridges), magnetic tape and disk heads (such as those in audio and video tape recorders and floppy disk drives), the lenses of lasers in optical disc drives (e.g., CD, DVD) and removing thermal paste from heatsinks and IC packages.

Intermediate:-

Isopropyl alcohol is esterified to give isopropyl acetate, another solvent. It reacts with carbon disulfide and sodium hydroxide to give sodium isopropylxanthate, a herbicide and an ore flotation reagent. Isopropyl alcohol reacts with titanium tetrachloride and aluminium metal to give titanium and aluminium isopropoxides, respectively,the former a catalyst, and the latter

DFPCL TALOJA

Page 13: PRANAY REPORT

13

Maintanance and Case study of pumps

a chemical reagent.This compound may serve as a chemical reagent in itself, by acting as a dihydrogen donor in transfer hydrogenation.

Medical:-

Rubbing alcohol, hand sanitizer, and disinfecting pads typically contain a 60–70% solution of isopropyl alcohol in water. Water is required to open up membrane pores of bacteria, which acts as a gateway inside for isopropyl. A 75% v/v solution in water may be used as a hand sanitizer.Isopropyl alcohol is used as a water-drying aid for the prevention of otitis external, better known as swimmer's ear.

Automotive:-

Isopropyl alcohol is a major ingredient in "gas dryer" fuel additives. In significant quantities, water is a problem in fuel tanks, as it separates from the gasoline, and can freeze in the supply lines at cold temperatures. Alcohol does not remove water from gasoline; rather, the alcohol solubilizes water in gasoline. Once soluble, water does not pose the same risk as insoluble water, as it will no longer accumulate in the supply lines and freeze. Isopropyl alcohol is often sold in aerosol cans as a windshield de-icer. Isopropyl alcohol is also used to remove brake fluid traces from hydraulic braking systems, so that the brake fluid (mineral oil) does not contaminate the brake pads, which would result in poor braking.

Toxicology:-

Isopropyl alcohol and its metabolite, acetone, act as central nervous system (CNS) depressants.Symptoms of isopropyl alcohol poisoning include flushing, headache, dizziness, CNS depression, nausea, vomiting, anesthesia, hypothermia, hypotension, shock, respiratory depression, and coma.Poisoning can occur from ingestion, inhalation, or skin absorption, therefore, well-ventilated areas and protective gloves are recommended. Around 15 g of isopropyl alcohol can have a toxic effect on a 70 kg human if left untreated.However, it is not nearly as toxic as methanol or ethylene glycol.

Isopropyl alcohol does not cause an anion gap acidosis (in which a lowered blood serum pH causes depletion of bicarbonate anion) unlike ethanol and methanol. Isopropyl alcohol does, however, produce an osmolal gap between the calculated and measured osmolalities of serum, as do the other alcohols. Overdoses may cause a fruity odor on the breath as a result of its metabolism to acetone, which is further metabolized to produce the nutrients acetate and glucose.

ISOPROPYL ALCOHOL PRODUCTION IN DFPCL

DFPCL TALOJA

Page 14: PRANAY REPORT

14

Maintanance and Case study of pumps

Having set up India's largest plant for producing Iso Propyl Alcohol with an installed capacity of 70,000 MTPA, DFPCL manufactures IPA through an extremely efficient and environment friendly, direct hydration process, producing a colourless product of high purity, with no undesirable odour or by-product formation. The product meets international quality standards for use in pharmaceuticals, coatings and inks, specialty chemicals and cosmetics. For critical applications in the pharma sector, DFPCL offers IPA conforming to stringent standards such as USP, PhEuro and IP to name a few.

DFPCL has a fully automated drumming facility for catering to small consumers and for meeting the increasing demand from neighbouring countries for exports. Our product has been well accepted in various markets such as USA, EU, AFRICA, MIDDLE EAST and FAR EAST. DFPCL also offers GMP Grade IPA which is Benzene free which meets the monographs of all the international pharmacopoeias.

BASIC PLANT DESCRIPTION:

The basic raw material for isopropanol manufacture is the chemical grade propylene with a minimum purity of 98%. As we donot have the direct source of this gradeof propylene refinery grad, propylene is purchased from BPCL which contains 70-75% of propylene and is further purified by fractionation by seperating out the propane content and other light impurities.

The plant uses the above purified propylene gas and demineralised water to produce the IPA product.

The production of isopropanal is used in production of

AMINES

ESTERS

GLYCERINE

JET ENGINE FUELS

JET ENGINE FUELS

DFPCL TALOJA

Page 15: PRANAY REPORT

15

Maintanance and Case study of pumps

SPECIALILY IN KS

The phosphoric acid catalyst is held within the reactor on an inert silica fill.The 95% unreacted propylene gas is recovered by the recycle gas compressors.

The crude IPA from reaction is fed to distillation section of the plant where unwanted byproducts such as ethers, acetone, NPA, hexene are removed giving final pure IPA product.

DESIGN CONDITIONS OR INFORMATION :

Due to the metallurgy of the carbon steel used for construction, minimum operating temperature of the system is limited to -28degrees to avoid chilling of the steel and it is subsequent embrittlement.This is of particular concern when liquid propylene is flashed into the system at low pressure during start up.The maximum design temperature of the system doesnot allow steaming out of equipment in shutdown.

DESCRIPTION AND CONTROL:

The top 5 trays in the tower acts as a pasteurising section to remove mainly ethane, methane, ethylene.The distillation section consists of a number of coloumns and their associated drums,exchangers etc.

The plant storage facility has dedicated tanks for product and by-products.The important auxillary systems associated with IPA plant are demineralised water plant:-

DEMINERALISED WATER PLANT

COOLING TOWER

STEAM AND CONDENSATE STEAM

HOT WATER SYSTEMS

FLARE SYSTEMS

DFPCL TALOJA

Page 16: PRANAY REPORT

16

Maintanance and Case study of pumps

MAINTENANCE PHILOSOPHY

Maintenance is the process of keeping a particular machine or asset in its normal operating condition without any loss of time or breakdown.Machines are to be machined in such a way so that it can be utilized to fullest extent.Maintenance raises equipment performance but adds cost of production.We have to strike a balance for optimum maintenance cost and productivity.

OBJECTIVES :

1. Equipment/Facilities always to be in optimum working conditions.2. Delivery schedule to customer not to be affected by equipment availability.3. Performance of equipment to be reliable.4. Down time of machines to be minimum.5. Maintenance cost to be monitored to control overhead cost.6. Spare parts management to be optimized.7. Maximize operational efficiency.

CHALLENGES :

1. Rapid growth in techmology makes current technology obsolete.2. Advent of new diagnostic tools,rapid repair system.3. Requirement to keep both outdated and modern machines with latest technology.4. Added responsibilities includes- upgradation of existing plant and equipment,training

of maintenance personel to attain reqd.skills.5. Effective equipment of old equipment for higher availability.6. Cost optimization of all maintenance function.

TYPES :

UNPLANNED : Unplanned maintenance is also known as: reactive maintenance, corrective maintenance, breakdown maintenance.Unplanned maintenance occurs in any asset maintenance plan and unfortunately is unavoidable. A common example of this type of maintenance (and the inconvenience that it can cause) is having your car break down on the side of the road, and having to wait for a mechanic to come to repair it. The trigger for this type of maintenance is a breakdown trigger.Because this maintenance type is both unplanned and unscheduled this method of performing maintenance activities is highly inefficient. Time needs to be spent investigating and determining the problem as well as determining a maintenance plan to get the equipment fixed quickly. Time is also likely to be spent waiting for parts, supplies or other personnel to complete the maintenance task.This type of maintenance can also be very expensive. Additional costs include time spent waiting, the premium costs that may be spent on fast part orders and shipping, and the possible overtime payments that may be required for additional, or specialized personnel needed to complete the task. In addition, because it is likely that the operation of other parts of the facility will be negatively impacted by the breakdown

DFPCL TALOJA

Page 17: PRANAY REPORT

17

Maintanance and Case study of pumps

of the machine in need of repair, the costs of lost production need to be also factored into the cost of this type of maintenance.

PLANNED : It is a organized type of maintenance,it takes care of control and record required for this type of work.Maintenance work is planned before hand.

OVERHAULING : Overhauling is the process of physical inspection of individual parts to assess their condition and to rectify and to bring it to normal state to ensure trouble-free operation till next overhaul. We should perform overhauling when performance is poor,consuming more power,machine produces more noice,vibrates heavily or fixed as per manual.

Equipment downtime is decreased and the number of major repairs are reduced. Better conservation of assets and increased life expectancy of assets, thereby eliminating

premature replacement of machinery and equipment. Reduced overtime costs and more economical use of maintenance workers due to

working on a scheduled basis instead of a crash basis to repair breakdowns. Timely, routine repairs circumvent fewer large-scale repairs. Improved safety and quality conditions for everyone.

DFPCL TALOJA

Page 18: PRANAY REPORT

18

Maintanance and Case study of pumps

PUMPS

A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action. Pumps operate by some mechanism (typically reciprocating or rotary), and consume energy to perform mechanical work by moving the fluid.Pumps operate by some mechanism (typically reciprocating or rotary), and consume energy to perform mechanical work by moving the fluid. Pumps operate via many energy sources, including manual operation, electricity, engines, or wind power, come in many sizes, from microscopic for use in medical applications to large industrial pumps.Mechanical pumps serve in a wide range of applications such as pumping water from wells, aquarium filtering, pond filtering and aeration, in the car industry for water-cooling and fuel injection, in the energy industry for pumping oil and natural gas or for operating cooling towers. In the medical industry, pumps are used for biochemical processes in developing and manufacturing medicine, and as artificial replacements for body parts, in particular the artificial heart and penile prosthesis.

DFPCL TALOJA

Page 19: PRANAY REPORT

19

Maintanance and Case study of pumps

Possitive diplacement pumps: A positive displacement pump makes a fluid move by trapping a fixed amount and forcing (displacing) that trapped volume into the discharge pipe. Liquid flows into the pump as the cavity on the suction side expands and the liquid flows out of the discharge as the cavity collapses. The volume is constant through each cycle of operation.

A positive displacement pump can be further classified according to the mechanism used to move the fluid:

Rotary-type positive displacement: internal gear, screw, shuttle block, flexible vane or sliding vane, circumferential piston, flexible impeller, helical twisted roots (e.g. the Wendelkolben pump) or liquid-ring pumps

Reciprocating-type positive displacement: piston or diaphragm pumps.

Centrifugal pumps: Centrifugal pumps are used to transport fluids by the conversion of rotational kinetic energy to the hydrodynamic energy of the fluid flow. The rotational energy typically comes from an engine or electric motor. The fluid enters the pump impeller along or near to the rotating axis and is accelerated by the impeller, flowing radially outward into a diffuser or volute chamber (casing), from where it exits.

Common uses include water, sewage, petroleum and petrochemical pumping. The reverse function of the centrifugal pump is a water turbine converting potential energy of water pressure into mechanical rotational energy.

How it works: Like most pumps, a centrifugal pump converts rotational energy, often from a motor, to energy in a moving water or fluid. A portion of the energy goes into kinetic energy of the water or fluid. Water or Fluid enters axially through eye of the casing, is caught up in the impeller blades, and is whirled tangentially and radially outward until it leaves through all circumferential parts of the impeller into the diffuser part of the casing. The water or fluid gains both velocity and pressure while passing through the impeller. The doughnut-shaped diffuser, or scroll, section of the casing decelerates the flow and further increases the pressure.

DFPCL TALOJA

Page 20: PRANAY REPORT

20

Maintanance and Case study of pumps

Preventive maintanance of pumps : 1. ONLINE – Tightening of Gland Nuts. Tightening of Flange nuts. Top up with oil. Replenishment of Grease. Oil leakages. Observations.2. SHUTDOWN – Gland packing. Bearing replacement. Alignment. Coupling pads, bushes. Suction filters/Foot valves. Valve replacement. Oil/Grease replacement. Repairs, which cannot be taken online.3. OVERHAULING- Overhauling of a pump is the process of physical inspection of the

individual parts to assess their condition and to rectify and to bring it to normal state to ensure trouble free operation till next overhaul.

Conditions for Overhauling : When there is no sufficient flow. When there is no sufficient head. It consumes more power. Pump produces more noise. Pump vibrates heavily. Pump breakdown is frequent. Fixed period as per manual.

Overhauling Activities :

Shut down. Remove from base. Dis-assembly. Clean and inspection. Repair at workshop. Manual Repair. Assembly. Fixing on base. Alignment. Test Run. Handover.

DFPCL TALOJA

Page 21: PRANAY REPORT

21

Maintanance and Case study of pumps

Refilling of gland Packings : Remove old packing. Use packing hook. Note location of the seal cage or lantern ring. Clean interior of box thoroughly. Check-shaft protection sleeve for wear. Replace sleeve ,if damaged. Check shaft run out.(Maximum-0.02 to 0.03mm). Measure new packing length. Cut to size. (Preferably at an angle.) Insert new packing,inside the box. Stagger joints of successive packing rings. Tightening nuts to keep packing in proper position. Loosen the nuts and keep them hand tight. Adjust gland leak after filling pump with liquid.

Pump dismantling :

Drain oil and remove bearing housing. Remove gland packing and then the stuffing box. Punch identification number on stage casing. Unscrew nuts on connecting rods and remove them. Remove outlet cover with diffuser. Dismantle the impellers,distance bush and stage casing in sequence. When the last casing is removed,pull shaft together with last impeller. Remove impeller,shaft

protection aleeve from the shaft. Stack stage casing on top of one another.

Inspection and Measurements :

Check ‘Out of round’of shaft and impellers.(0.02-0.03mm). Examine contact surfaces of stage casings(Max.tolerance 0.05mm).The surface roughness

must not exceed Ra=1.6m. Inspect impeller for signs of damage. Inspect Distance bushes,keys and keyways. Make spare parts available at site before starting assembly.

Dynamic Balancing of rotor with all rotating parts , should be carried out ,if any repair has been done on them or any part has been replaced.

Assembly :

Before reassembly,the axial face to face length must be measured. E1=E2.

DFPCL TALOJA

Page 22: PRANAY REPORT

22

Maintanance and Case study of pumps

Coat all rotating parts with MoS2. Fix the shaft protection sleeve with the “Out ring on inlet side of shaft.” Insert shaft into the inlet cover. Mount stage casings with diffusers and Impellers assembly stage by stage. Total Axial clearance. Sa1+Sa2. Tighten connecting rods as per correct tightening torque. Fix stuffing box assembly,then the bearing housing. Lock the bearing. Fix coupling half. Put gland packing inside the stuffing box. Align the pump with the motor. The Pump is ready for operation.

LUBRICATION When two parts are in relative motion,there is every possibility of friction between the two

Surfaces.Friction causes wear,heat generation and also more power consumption. To reduce

Friction and wear,Lubrication is needed.In Pumps,lubrication is done in the bearings,by

Either OIL or GREASE.

1. OIL REPLACEMENT : A. Shutdown machine :- Stop machine. Drain oil. Clean inside. Clean with flush oil. Fill with proper grade ,contaminant free oil. Restart machine. Temperature will rise at first,but will fall to normal after sometimes.B. Running machine :- Fill fresh oil from top of the bearing housing slowly and gradually. Simultaneoulsy drain from the bottom such that the level in the sump remains almost

constant. When the old oil is completed replaced by the new oil,close drain and stop filling.

2. REGREASING OF BEARINGS : a) Shutdown Machine :- Stop machine. Open housing cover.

DFPCL TALOJA

Page 23: PRANAY REPORT

23

Maintanance and Case study of pumps

Remove old grease and clean bearing and housing. Fill the bearing with grease. Fill 50% to 60% of the housing with grease. Fit the cover and start machine.

b) Running machine :- Open the drain plug. Fill grease by the grease gun through the nipple at top. Observe old grease coming out of the drain. Continue greasing till all old grease comes out and some new grease starts coming. Stop pumping any more grease. Allow all excess grease to come out. Close plug.

TROUBLE SHOOTING OF PUMPS

DFPCL TALOJA

Page 24: PRANAY REPORT

24

Maintanance and Case study of pumps

SCREW PUMP FAULT ANALYSIS FAULT POSSIBLE CAUSES NO DELIVERY OR REDUCED DELIVERY

Inlet and outlet wrongly connected. Wrong direction of rotation. Excessive suction lift. Viscosity not within permissible range. Relief valve incorrectly adjusted. Air leakage into inlet. Inlet pipe diameter inadequate. Low pump speed Inlet stainer clogged.

PUMP SEIZED Foreign parts jammed inside. Pump operating dry. Misalignment

PUMP VIBRATES OR IS NOISY Excessive suction lift. Air leakage into inlet. Foundation bolts loose. Inadequate suction pipe diameter. Gland packing or mechanical seal damaged. Bearings damaged.

NO LIQUID FLOW Pump not vented properly. Suction too close to reservoir. Speed too low or too high. High back pressure. Foreign bodies inside impeller.

LESS LIQUID FLOW Casing wearing rings badly worn out. Impeller damaged or disintegrated. Leakage through casing partitions. Suction filter choked.

TOTAL HEAD TOO LOW Speed too high. Reverse rotation. High back pressure Rotating elements foul with fixed elements. Casing wearing rings worn out.

EXCESSIVE GLAND LEAKAGE Mis-alignment. Bent shaft. Bearings damaged . Shaft protection sleeves ‘O’ rings worn. Stuffing box badly packed. Improper size and quality of packing. Rotor vibration.

PUMP VIBRATES Suction line incompletely primed. Pump operates at too low flow rate. Foreign bodies inside impeller. Pump misaligned. Shaft bent.

DFPCL TALOJA

Page 25: PRANAY REPORT

25

Maintanance and Case study of pumps

Rotary elements foul with fixed elements. Bearings badly worn. Impeller damaged. Faulty bearing assembly.

BEARINGS LIFE TOO SHORT Pump Misalignment. Pump not in level. Shaft bent. Rotating elements foul. Rotor vibrations. Lubricants not proper. Faulty bearing assembly. Rearing brackets not tightly fixed. Ingress of water into bearing housing.

Study On 9101 AIB Verticle Centrifugal Pump

DFPCL TALOJA

Page 26: PRANAY REPORT

26

Maintanance and Case study of pumps

1) Erection(Installation at site) : A special base frame must be fitted flush on shims in the foundation or cover aperture to receive the pump set. The concrete base must have set before the base feame is fitted.Carefully level the machined seating face for the barrel flange using a precision spirit level,use stainless steel shims to compensate for any differences in height..

2) Checking the direction of rotation : The direction of rotation of the driver must coincide with the directional arrow on pump.The direction of rotation check must be carried out with the driver disconnected from the pump.The driver is automatically centered in the flange of the motor lantern after being placed and bolted on motor lantern.

3) Start up : Opening the isolating valve in the suction line fully,keep the isolating valve in the discharge side fully and switch on the pump.Only after the pump has attained its full operating speed should the isolating valve in the discharge line be opened slowly and gradually,and used to adjust the operating duty point.Then vent valves on the discharge side should be closed.

4) Maintenance : The pump must run smoothly,quietely and free from vibrations at all times. The pump must never be allowed to run dry. Prolonged running against a closed discharge valve must be avoided. The liquid level must always be situated at an adequate height above the

pump inlet. The temperature in the thrust bearing of the pump may be allowed toattin

upto 50C above ambient temperature,but should not exceed +90C,measured at the outer wall of the bearing housing.

The isolating valves in the supply lines must not be closed whilst the pump is running.

The gland packing should drip slightly whilst the upmp is running.The gland should only be tightened lightly.

If standby pumps are installed,these should be switched on and switched off again immediately once a week,in order to maintain them in a state of readinesss for intant start ups in an emergency.

The proper functioning of the auxillary connections must be checked and supervised.

5) Lubrication : The support bearing is lubricated by the oil fill in the bearing housing.An oil elevator tube inside the centering sleeve supplies oil to antifriction bearing.The requisite oil level is maintained by a constant level oiler.The reservoir of this constant level oiler must therefore always be kept topped up with oil.

The first oil change should take place after the first 300hours of operation and subsequent oil changes should be effected after every 3000hours of operation,but atleast once a

DFPCL TALOJA

Page 27: PRANAY REPORT

27

Maintanance and Case study of pumps

year.Unscrew and remove the drain plug on the bearing housing and drain the oil.After draining of the bearing housing,replace the drain plug and fill in fresh oil.The pump bearings and intermediate shaft bearings are lubricated directly by the product pumped.No special maintenance of these bearings is necessary,but pump must not be allowed to run dry.

6) Packing the box :

Fitting new packing :- Throughly clean the packing compartment and the shaft protection sleeve and coat them with molybdenum disulphide.Insert neck ring(457) and press it home until it abuts ,insert the packing rings individually and push them with the aid of the stuffing box gland and seal cage ring.The ring butt of each packing ring should be offset 90 degrees in relation to the joints of the adjoining rings.Insert seal cage ring(458) so that it registers opposite connection.Then insert the remaining packing rings individually.Leave a sufficient clearance gap at the entrance of the stuffing box for the positive guidance of the gland.The inserted packing rings should only be lightly compressed by the gland and the nuts.

Removing the packing :-Slacken clamping ring(184) and remove it from shaft protection sleeve(524),undo stuffing box gland(452) and pull it out of stuffing box housing(451).Pull the top packing rings out of stuffing box housing with the aid of a packing ring extraxtor,pull out seal cage ring,them remove the remaining packing rings and examine shaft protection sleeve for signs of damage.Clean the packing compartment and coat it with molybdenum disulphide.Pack the stuffing box.

7) Cooling sealing liquid : If the temp of product pumped exceeds 105C,a heat barrier is fitted between the distributor casing and the stuffing box housing.The stuffing box housing is provided with a cooling cover with connections7E/7A for the cooling liquid.Water from the an outside source with hardness upto 8DH,calcium hardness ,or collled product can be used for cooling purposes.If an aggressive coolant is used,the parts in contact with the coolant must be made of suitably resistnt material.

Examination of individual components:

Shafts : Inspect the bearings sleeves shrunk onto the shafts for signs of galling,Slight traces of damagecan be removed by grinding within the permissible clearance limits.If

DFPCL TALOJA

Page 28: PRANAY REPORT

28

Maintanance and Case study of pumps

the touching up works should result in the permissible clearances being exceeded,then new bearing sleeves must be shrunk on.Carry out an out of round check on a lathe between dead centres.The max. permissible shaft whip must not exceed 0.03mm.Make sure the shaft is accurately centered on the lathe,as otherwise the readings will be erroneous.If certain rotor components are replaced by new ones,or have been touchedup,or if a new shaft has been fitted,the pump rotor must be balanced dynamically,preferably at the max.

Bearing arrangement : Even if they only exhibit slight discoloration marks or specks of rust,or signs of damage to the running surfaces,the bearings must be replaced by new ones.Observe the greatest cleanliness when mounting the bearings.Use washing oil to clean the old bearings. After washing,the bearings should be dried and immediately sprayed with oil.

Shaft seals : Use new packing material every time the pump is overhauled.The shaft protection sleeve may only be touched up very lightly by grinding.If it exhibits signs of damage, a new shaft protection sleeve should be fixed.

Dynamic balancing of pump rotor : Assembly proceeds from the front end;slip stage sleeve onto pump shaft until it abuts against the shaft shoulder.Insert key and slip final stage impeller onto the shaft ubtil it abuts.Mount the stage sleeve-keys and impellers of the remaining stages in sequence as described.Fit the split ring an key.Push on the bearing sleeve and suction impeller.Before dynamic balancing ,the rotor should be checked for true running(out of round) at the impellers and at the neraings.The measured out of round value must not exceed 0.03mm.The rotor should then be dynamically balanced at max.pump operating speed if possible.

DFPCL TALOJA

Page 29: PRANAY REPORT

29

Maintanance and Case study of pumps

Characteristics curve for a typical centrifugal pump

Sooner or later, most maintenance professionals who work with pumps will encounter a pump curve and its key parameters, one of which is Best Efficiency Point (BEP). The BEP graphically represents the point on a pump curve that yields the most efficient operation. For electric motors, efficiency varies with load, with the best efficiency being at about 75% of load. With rotodynamic pumps (which includes centrifugal and axial flow types), efficiency depends on three important pump curve parameters—head, flow (i.e., capacity or volume) and power—as expressed in the above equation:

As the equation shows, power is inversely proportional to efficiency, which basically means pumps use less power when operating more efficiently. But power is also directly proportional to flow X head (Q X H), both of which vary with demand in a rotodynamic pump system. If the system restricts the discharge of the pump, as when a discharge throttle valve is closed, the flow decreases and the head increases. Conversely, less restriction from the system means greater flow and less head.

DFPCL TALOJA

Page 30: PRANAY REPORT

30

Maintanance and Case study of pumps

Effect of flow rate : To visualize how flow affects pump efficiency, imagine the flow of traffic on a highway, with efficiency measured as cars per minute. Late at night with no cars on the road (and therefore no traffic), efficiency is zero. Early in the morning, traffic moves quickly, but with few cars traveling, efficiency remains low. During rush hour traffic volume greatly increases, so bottlenecks form, traffic slows to a crawl and efficiency plummets. Usually, there is a time just before rush hour with lots of fast-moving traffic when the highway handles the most cars per minute—i.e., its BEP.

The BEP for a pump is similar (see Fig. 3). With the discharge valve closed (“dead head”) and zero flow, efficiency is zero. As the discharge valve opens (i.e., the discharge restriction is gradually reduced), flow and efficiency gradually increase, until the flow through the pump becomes more turbulent. At that point, efficiency will start dropping and then continue to drop as the pump approaches “run out” condition (zero). As with traffic flow on a busy highway, somewhere between “dead head” and “run out” condition, there is a flow rate at which the efficiency is maximum—i.e., the BEP.

Effect of impeller design : Impeller design is the most significant factor for determining the BEP of a pump because it dictates how efficiently power (brake horsepower or BHP) is transmitted to the liquid being pumped (“pumpage”). A properly designed impeller optimizes flow while minimizing turbulence.

Pumpage enters the impeller eye and accelerates as it travels radially outward toward the impeller discharge. As the liquid discharges from the impeller, it merges with liquid already in the impeller housing. If the impeller vanes are at just the right angle relative to the flow rate, incoming pumpage will merge smoothly with the swirling pumpage in the housing, minimizing turbulence, maximizing efficiency and yielding the BEP for that impeller.

Designers use a series of vectors to calculate impeller vane angle for a certain flow rate. As shown in Fig. 4, vector Vt represents the speed of the vane tip (tangent and relative to the impeller), and Vr represents the radial velocity of the pumpage flowing out of the impeller. The discharge angle of the flow is Vm, the sum of vectors Vt and Vr, which should match the impeller vane angle at the discharge. The length of vector Vr changes with flow rate, so greater flow through the pump means the pumpage must move faster as it exits the impeller.

DFPCL TALOJA

Page 31: PRANAY REPORT

31

Maintanance and Case study of pumps

Conclusion:After completing this report we conclude that the during this project I have attained deep knowledge about different types of pumps used at chemical and fertiliser industry and performed a detailed case study on 9101 A/B Verticle Centrifugal Pump.

The conclusion that we made that with an increased of speed of the pump it will cause the properties and characteristic to varied accordingly which in turn effect the overall efficiency, and with the increased of speed it is relevant that the efficiency also increased. The maximum operating condition is at 90% pump speed, where the efficiency is 40% at 1.7 m3/s capacity this is called BEP

The most important thing to remember from this discussion is that any modification of the impeller will change the BEP of the pump. Trimming the outside diameter (OD) of an impeller, replacing an impeller with one of different diameter or number of vanes or changing the rotating speed of the impeller will alter the BEP for the pump.

Before modifying an impeller in any way, make sure that you determine how the change will impact the pump curve, the efficiency curve and the BEP.

DFPCL TALOJA

Page 32: PRANAY REPORT

32

Maintanance and Case study of pumps

Recommendation:USE OF NICKEL RESIST IRON:-Ni-Resist irons are alloy cast irons in which a substantial addition of nickel has produced an authentic matrix structure.The matrix is tough,heat-resisting and stable under chemical attack giving outstanding performace in contact with a wide range of commonly occuring corrosives.They are not completely stainless,but they form adhering film of rust which prevents further corrosion and doesnot flake off to contaminate the product handled.

They show to advanatge in many environmentswhen compared with carbon steel and ordinary cast irons.

Ni-Resist pumps can also be used in other water services.The resistance of Ni-Resist irons to sea water corrosion at higher temperatures can lead to their increasing use in desalination feedwater and brine pumps.

DFPCL TALOJA

Page 33: PRANAY REPORT

33

Maintanance and Case study of pumps

References: Centrifugal and axial flow pumps –Stepanoff. Pump application and engineering-Hicks and Edward. Metering pumps-Poypton. wikipidea

DFPCL TALOJA