PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND del Rey Castillo, Enrique 1 , Kanitkar, Ravi 2 , and Smith, Scott 3 1 Lecturer at the Department of Civil and Environmental Engineering, University of Auckland, New Zealand, 2 Principal at KL Structures, Austin, Texas, USA, and 3 Professor of Structural Engineering at the University of Adelaide ABSTRACT: The New Zealand Building Act of 2004 established a framework for assessing and managing earthquake-prone buildings in New Zealand, with the significance of this process being highlighted after the Canterbury earthquakes. The result of the assessment process is presented as a percentage of the New Building Standard (NBS), measuring how resilient the building is to seismic actions. The minimum requirement for existing buildings is 34%NBS, although 67% is often required by insurance companies. Fibre Reinforced Polymer (FRP) composites have been used extensively as Externally Bonded Reinforcements (EBR- FRP) since the Building Act was enacted, mainly due to the versatility of application, as well as the high strength and light weight nature of the material (which does not increase the seismic weight of the structure). In EBR-FRP systems, the fibres (typically carbon fibres, although glass fibres have also been used) are bonded to the external surface of the concrete structure with epoxy resin. One of the main shortcomings of EBR-FRP systems is premature FRP-to-concrete debonding as a result of the low tensile strength of concrete. One way to overcome the adverse effects of premature debonding and to ensure the continuity of the load path is to use FRP anchors, which are bundles of fibres saturated in epoxy and introduced into the concrete structure. Several design guidelines have been produced since FRP products were introduced in civil engineering applications, with a widely used design document being published by the American Concrete Institute, namely ACI440.2R-17 “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures”. Other documents used include the Italian guideline CNR-DT200 and the fib Bulletin 14. While a design approach has been recently published by the authors, neither of these widely accepted codes include guidance on how to design FRP anchors. New Zealand engineers have typically relied on published research or have resorted to engineering judgement, often validates with proof-testing. A concise but comprehensive summary of the use of FRP anchors in the last decade has been summarised in this paper with a focus on innovative designs that required out-of-the-box thinking in order to develop creative solutions to difficult and complex problems. The works summarised herein have been obtained from a number of engineering firms, suppliers and installers. No specific engineer, products or companies are named in order to retain the neutrality and unbiased position of the authors.

Transcript of PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more...

Page 1: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND

del Rey Castillo, Enrique1, Kanitkar, Ravi2, and Smith, Scott3

1Lecturer at the Department of Civil and Environmental Engineering, University of Auckland, New Zealand, 2Principal at KL Structures, Austin, Texas, USA, and 3Professor of Structural

Engineering at the University of Adelaide

ABSTRACT: The New Zealand Building Act of 2004 established a framework for assessing and managing earthquake-prone buildings in New Zealand, with the significance of this process being highlighted after the Canterbury earthquakes. The result of the assessment process is presented as a percentage of the New Building Standard (NBS), measuring how resilient the building is to seismic actions. The minimum requirement for existing buildings is 34%NBS, although 67% is often required by insurance companies. Fibre Reinforced Polymer (FRP) composites have been used extensively as Externally Bonded Reinforcements (EBR-FRP) since the Building Act was enacted, mainly due to the versatility of application, as well as the high strength and light weight nature of the material (which does not increase the seismic weight of the structure).

In EBR-FRP systems, the fibres (typically carbon fibres, although glass fibres have also been used) are bonded to the external surface of the concrete structure with epoxy resin. One of the main shortcomings of EBR-FRP systems is premature FRP-to-concrete debonding as a result of the low tensile strength of concrete. One way to overcome the adverse effects of premature debonding and to ensure the continuity of the load path is to use FRP anchors, which are bundles of fibres saturated in epoxy and introduced into the concrete structure. Several design guidelines have been produced since FRP products were introduced in civil engineering applications, with a widely used design document being published by the American Concrete Institute, namely ACI440.2R-17 “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures”. Other documents used include the Italian guideline CNR-DT200 and the fib Bulletin 14. While a design approach has been recently published by the authors, neither of these widely accepted codes include guidance on how to design FRP anchors. New Zealand engineers have typically relied on published research or have resorted to engineering judgement, often validates with proof-testing.

A concise but comprehensive summary of the use of FRP anchors in the last decade has been summarised in this paper with a focus on innovative designs that required out-of-the-box thinking in order to develop creative solutions to difficult and complex problems. The works summarised herein have been obtained from a number of engineering firms, suppliers and installers. No specific engineer, products or companies are named in order to retain the neutrality and unbiased position of the authors.

Page 2: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

INTRODUCTION

A framework for assessing and managing earthquake-prone buildings in New Zealand was established in 2004, under which the buildings are classified to a percentage of the New Building Standard (NBS). A minimum requirement was established by law at 34%, but that lower limit is typically superseded by a minimum 67% requirement by insurance companies. While many different methods exist to elevate the NBS rating of an existing building, the use of Fibre Reinforced Polymers (FRP) is often preferred mainly due to the high strength and the light weight of the material, and the versatility of the system. One of the most common methods to use FRP is by using Externally Bonded Reinforcements (EBR), which involves the soaking of the fibres in epoxy resin and bonding the resulting composite to the external surface of the structure. However, the low strength of the concrete typically causes premature debonding of the FRP from the concrete surface, governing the strengthening system and reducing the efficiency of the EBR-FRP system to as low as 10% to 30% of the ultimate tensile strength of the FRP. Multiple methods exist to overcome the problem of premature debonding, but the use of FRP anchors is often preferred to avoid steel-FRP incompatibilities and/or stress concentration, and to increase the durability of the system (Kalfat et al. 2013; Kalfat, Gadd, Al-mahaidi, et al. 2018; del Rey Castillo, Dizhur, et al. 2019). Further, the use of FRP anchors is especially critical in seismic strengthening interventions to provide the redundancy necessary if a larger-than-expected earthquake occurs.

FRP anchors consist of bundles or rovings of fibres soaked into epoxy and are used to ensure the continuity of the load path from the FRP sheet into the structure. One end of the bundle is introduced into a hole that has been pre-drilled into the structure, forming the anchor dowel, while the other end is splayed out, forming the anchor fan, as illustrated in Figure 1. While several standards and guidelines exist for the use of EBR-FRP systems to strengthen existing structures (ACI 440.2R 2017; CNR-DT 200 2013), no formal guidance exists for the use of FRP anchors. New Zealand engineers have typically relied on published research or have resorted to an engineering judgement, often backed up with proof-testing. All potential failure modes need to be considered when designing FRP anchors, similar to the design of post-installed steel anchors (ACI 355.2 2007). All such possible failure modes are illustrated in Figure 1, with the concrete-related failure being investigated by Prof. Scott Smith (2010), the fibre rupture failure modes being investigate by Dr. Enrique del Rey Castillo (2019b; 2019a), and the fan-to-sheet failure mode being firstly proposed by Ravi Kanitkar (2016) with further improvements (2019). Finally, a design approach was proposed by the authors, based on the minimum ultimate load that each anchor has to withstand (2019). Starting with that minimum load, the design process ensures that each failure mode is avoided, thus shifting the failure to the FRP sheet, as can be seen in the flowchart from Figure 2.

Page 3: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

Figure 1 Failure modes of anchors, extracted from (del Rey Castillo, Kanitkar, et al. 2019)

Figure 2 Design procedure, extracted from (del Rey Castillo, Kanitkar, et al. 2019)

Dowel

Fan

Page 4: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

EXAMPLES OF FRP ANCHORS IN PRACTICE

The versatility of FRP-EBR offers a wide range of possibilities for the use of FRP anchors, from relatively simple shear strengthening of beams to floor diaphragms with complex load paths. A few examples are reported in this section.

Shear strengthening of beams

Shear strengthening of beams is typically motivated by change of use or design/construction errors, and has been extensively investigated in the past, e.g. (Kalfat et al. 2011). In seismic environments, shear strengthening of coupling beams is also common to confine the plastic hinges and ensure ductility, as in the examples illustrated in Figure 3. The scheme consists of installing a U-shaped sheet at the bottom and sides of the beam, with holes being drilled through the slab and the anchors being passed through, as can be seen in Figure 3a. Several options exist to anchor the system at the top of the coupling beam, with the two most commonly used being making a closed tie with the FRP bundles with the top countersunk within grooves in the top of the slab, or opening up the bundles to create a circular splay at the top, often covered with another layer of FRP to distribute forces and protect the splay, as can be seen in Figure 3b, Figure 3c and Figure 3d respectively. From a structural performance point of view, both systems work equally well, as long as the quality of installation is appropriate. Using grooves might be more preferred because the FRP can be concealed in the concrete cover, ensuring the FRP is protected during the installation of the flooring system.

(a) Bottom view of the coupling beam, with the anchor fans being splayed out

(b) Ties at the top of the coupling beam to close the loops and ensure confinement

(c) Circular “plug” splays to secure the anchors

(d) Covering the “plug” splays to improve the distribution of forces and protect them

Figure 3 Examples of shear strengthening of coupling beams

Page 5: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

Flexural strengthening of beams and slabs

The most common use of FRP strengthening in New Zealand is to improve the seismic performance of the structural element. However, there are many instances wherein the vertical load-carrying capacity of a beam or slab has to be increased. The use of FRP anchors ensures that the longitudinal FRP sheet bonded to the soffit of the beam will not debond prematurely, either due to intermediate flexural cracks or to end peel-off. Extensive research has been undertaken for such anchoring, see for example a recent review on anchorage methods for flexurally strengthened concrete members (Kalfat, Gadd, Al-Mahaidi, et al. 2018). An example of this scheme is included in Figure 4. In some cases the flexural FRP is continued to the supports, and the anchors are doweled into the supporting columns or girders.

Figure 4 Flexural strengthening of concrete beams with EBR-FRP and FRP anchors

Shear strengthening and confinement of columns

The use of FRP materials to improve the confinement and/or the shear strength of concrete columns is one of the earliest and most common applications of FRP strengthening of existing structures. The use of FRP anchors improves the effectiveness of the confinement when corners and re-entrants are present, preventing the FRP confinement from peeling off or pulling out and ensuring the continuity of the confinement, such as in Figure 5. FRP anchors are extensively implemented in practice despite the limited research and design guidance available.

Figure 5 Examples of FRP anchors in combination with shear/confinement of columns

Page 6: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

Flexural strengthening of columns

Once the ductility and shear capacity of the column has been provided as described above, the flexural and moment capacity of the column can be increased by bonding FRP sheets in the longitudinal direction of the column. Anchoring the sheets to the foundation or continuing the load path thorough the floor system becomes imperative to avoid plastic lumping at the bottom single crack and rigid body rotation. Limited research exists on this strengthening scheme, but the effectiveness of the system has been proven at a structural element level (del Rey Castillo et al. 2018). Further research is needed to investigate the effects of the stiffening of the column on the whole structure. An example of a building strengthened using this method is reported in Figure 6, using anchors for both ensuring the continuity of the confinement, as explained above, and the continuity of the flexural strengthening through floors and into the foundation.

(a) Picture of the FRP-strengthened column

(b) Drawings of the strengthening design

Figure 6 Flexural and shear strengthening of a concrete column

Shear strengthening of walls

Multiple studies have been published on FRP strengthening of walls using FRP anchors to remediate the multiple failure modes that walls can exhibit, and a project is currently on-going at the University of Auckland to provide guidance on the design of FRP strengthening of walls incorporating FRP anchors. The most common failure modes addressed are shear failure, failure of the boundary regions either by concrete crushing or rebar buckling, and flexural failure, as illustrated in Figure 7a, b and c respectively. The ACI 440 (ACI 440.2R 2017) standard incorporated an example of how to design seismic strengthening of walls to improve the shear and flexural capacity, but did not address FRP anchors.. Despite the prevalence of wall systems in New Zealand, no examples of practical use of FRP anchors on the strengthening of walls could be found, the potential reason being high cost. The authors would appreciate any information that could be provided on this regard.

Page 7: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

(a) shear strengthening of walls according

to (Altin et al. 2013)

(c) Flexural strengthening according to (Dan

2012)

(b) boundary region strengthening

according to (Dan 2012)

Figure 7 Strengthening of concrete walls

Strengthening of floor diaphragms

No research could be found on the FRP strengthening of floor systems to ensure diaphragm action to resist earthquakes, with only one conference paper being found in the literature (Ormeno et al. 2019). Also, none of the current design guidelines offer any guidance for diaphragm strengthening with FRP. Despite the lack of data, this strengthening scheme is being extensively used in New Zealand, especially in Wellington given the profusion of hollow-core systems and the inherent weaknesses and brittleness of the system. Common features of this type of interventions is the use of an orthogonal grid of FRP sheets bonded to the top surface of the concrete floor and the anchorage of these sheets at the perimeter, sometimes including anchorages at the crossing between the orthogonal sheets. Although FRP anchors are not always used, they are prevalent in this type of systems

Page 8: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

(a) Anchoring the cross between orthogonal sheets with “plug” anchors

(b) Anchoring the end of the sheets to the bond beam at the perimeter

Figure 8 Examples of FRP strengthening of floor diaphrams

CONCLUSIONS

FRP anchors can be used in conjunction with EBR-FRP systems for every application, further exploiting the versatility of FRP systems and increasing the efficiency by ensuring the continuity of the load path and/or preventing or delaying premature debonding. No codified or standardised design method exists for FRP anchors, although a design approach for such anchors has been recently published. Further, very limited to no exists for the design of FRP anchors in the majority of the applications, even if these applications are included in current guidelines, such as ACI 440.2R, such as strengthening of walls. However, FRP anchors are being widely used in practice even in the absence of any design guidance, and often with virtually no experimental data to corroborate the expected behaviour of the strengthening system, such as in the strengthening of floor diaphragms. Finally, significant research is needed in specific applications, such as flexural strengthening of columns and strengthening of floor diaphragms, before design guidelines can even be created.

REFERENCES

ACI 355.2, 2007. Qualification of Post-Installed Mechanical Anchors in Concrete, Farming Hills, Michigan, U.S.A: American Concrete Institute (ACI) Comittee 355.

ACI 440.2R, 2017. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures, Farming Hills, Michigan, U.S.A: American Concrete Institute (ACI) Comittee 440.

Altin, S., Anil, O., Kopraman, Y. & M.E., K., 2013. Hysteretic behaviour of RC shear walls strengthened with CFRP strips. Composites Part B: Engineering, 44(1), pp.321–329.

CNR-DT 200, 2013. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Existing Structures, Rome, Italy: CNR (Consiglio Nazionale delle Ricerche) - Advisory Committee on Technical Recommendations for Construction.

Dan, D., 2012. Experimental tests on seismically damaged composite steel concrete walls retrofitted with CFRP composites. Engineering Structures, 45, pp.338–348.

Page 9: PRACTICAL USES OF FRP ANCHORS IN NEW ZEALAND P2 - del Rey Castillo_Kanitkar...grooves might be more preferred because the FRP can be concealed in the concrete cover, ... Gadd, Al-Mahaidi,

Kalfat, R., Gadd, J., Al-mahaidi, R. & Smith, S.T., 2018. An efficiency framework for anchorage devices used to enhance the performance of FRP strengthened RC members. Construction and Building Materials, 191, pp.354–375.

Kalfat, R., Gadd, J., Al-Mahaidi, R. & Smith, S.T., 2018. Evaluation and Classification of Anchorage Systems Used to Enhance the Flexural Performance of FRP Strengthened Concrete Members. Special Publication, 327(35), pp.1–10.

Kalfat, R., Al-mahaidi, R. & Smith, S.T., 2013. Anchorage Devices Used to Improve the Performance of Reinforced Concrete Beams Retrofitted with FRP Composites : State-of-the-Art Review. Journal of Composites for Construction, 17(1), pp.14–33.

Kalfat, R., Al-Mahaidi, R. & Smith, S.T., 2011. Anchorage devices used to improve the performance of reinforced concrete beams retrofitted with FRP composites: State-of-the-art review. Journal of Composites for Construction, 17(1), pp.14–33.

Kanitkar, R., Smith, S.T. & Lewis, C., 2016. An Experimental Investigation on the splay portion of embedded FRP tension anchors. In Proceedings of The 8th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering (CICE 2016). Hong Kong, China: Department of Civil and Environmental Engineering & Research Institute for Sustainable Urban Development, The Hong Kong Polytechnic University, pp. 413–418.

Kim, S.J. & Smith, S.T., 2010. Pullout Strength Models for FRP Anchors in Uncracked Concrete. Journal of Composites for Construction, 14(4), pp.406–414.

Ormeno, M., Jing, J., Roger, R. & del Rey Castillo, E., 2019. Capacity of diaphragm strengthened with FRP: comparison between ACI 440.2R and in-situ tests. In Proceedings of the 2019 New Zealand Society for Earthquake Engineering and Pacific Conference on Earthquake Engineering (NZSEE/PCEE). Auckland, New Zealand.

del Rey Castillo, E., Kanitkar, R., Smith, S.T., Griffith, M.C. & Ingham, J.M., 2019. Design approach for FRP spike anchors in FRP-strengthened RC structures. Composite Structures, 214(January), pp.23–33.

del Rey Castillo, E., Dizhur, D., Griffith, M.C. & Ingham, J.M., 2019. Strengthening RC structures using FRP spike anchors in combination with EBR systems. Composite Structures, 209, pp.668–685.

del Rey Castillo, E., Griffith, M. & Ingham, J., 2018. Seismic behavior of RC columns flexurally strengthened with FRP sheets and FRP anchors. Composite Structures, 203.

del Rey Castillo, Enrique, Griffith, M.C. & Ingham, J.M., 2019a. Experimental testing and design model for bent FRP anchors exhibiting fiber rupture failure mode. Composite Structures, 210, pp.618–627.

del Rey Castillo, Enrique, Griffith, M.C. & Ingham, J.M., 2019b. Straight FRP anchors exhibiting fiber rupture failure mode. Composite Structures, 207, pp.612–624.

del Rey Castillo, E., Kanitkar, R. & Smith, S.T., 2019. Fan-to-sheet failure mode of FRP anchors. In Proceedings of the 14th Symposium on Fibre Reinforced Polymer for Reinforced Concrete Structures (FRPRCS-14). Belfast, Northern Ireland.