X Platform CORE CORE CORE CORE Low Power Low Power Low Power Low Power RF SW Module RF SW Module RF SW Module RF SW Module The “CORE Low Power RF Switching Module” is the central and easily the most essential component for optimizing Production Line Cycle Time, specifically as regards any low power RF ATE station design. The realization of the best possible scenario for multiport testing is achieved by reducing not only the test time, but by also drastically reducing the number of required test technician interactions and thus lowering the overall amount of DUT handling. This module is expandable, using multiple modules, to a surprisingly high number of test ports with a very acceptable “bypass loss” of .6 dB to 1.1 dB for each added module, across the entire cellular test band. Application Features 6 DUT Test Ports 2 pair Test Equip Ports 2 Module Bypass Ports ‘Universal’ Module Control Module Supports up to two pieces of “2-port” low power RF test equipment. “Test Equip Ports” are selectable by pair and each port is fully multiplexed to all of the DUT Test Ports. “Module Bypass Ports” are dedicated to the active pair of Test Equip Ports and are selected similar to a DUT Test Port. Non-associated to any DUT Test Ports. “DUT Test Ports” are well isolated and are terminated very close to the front panel RF connection. “Universal Module Control” through a “no firmware, generic control hardware” design rule for all Xplatform modules. site commonality equip cost savings future proof design good performance Supported Options (per hardware design): RF Switches: Multiple Drive Types / Vendors Module Control*: TTL or TTL with I2C or only I2C Switch Cycle Counter** * Note: “Stand-Alone” Module USB control is within design capabilities ** Note: “Switch Cycle Counter” option availability to be announced RF EQUIP PORTS 1&2 DUT TEST PORTS 1~6 BYPASS PORTS RF EQUIP PORTS 3&4 RF EQUIP PORTS 1&2 DUT TEST PORTS 1~6 BYPASS PORTS RF EQUIP PORTS 3&4

Transcript of Powerwave xplatform core low power matrix switchbox red_hg

XPlatformCORE CORE CORE CORE Low PowerLow PowerLow PowerLow Power RF SW ModuleRF SW ModuleRF SW ModuleRF SW Module

The “CORE Low Power RF Switching Module”is the central and easily the most essential component for optimizing Production Line Cycle Time, specifically as regards any low power RF ATE station design.

The realization of the best possible scenario for multiport testing is achieved by reducing not only the test time, but by also drastically reducing the number of required test technician interactions and thus lowering the overall amount of DUT handling.

This module is expandable, using multiple modules, to a surprisingly high number of test ports with a very acceptable “bypass loss” of .6 dB to 1.1 dB for each added module, across the entire cellular test band.

Application Features

• 6 DUT Test Ports

• 2 pair Test Equip Ports

• 2 Module Bypass Ports

• ‘Universal’ Module Control

Module Supports up to two pieces of “2-port” low power RF test equipment.

“Test Equip Ports” are selectable by pair and each port is fully multiplexed to all of the DUT Test Ports.

“Module Bypass Ports” are dedicated to the active pair of Test Equip Ports and are selected similar to a DUT Test Port. Non-associated to any DUT Test Ports.

“DUT Test Ports” are well isolated and are terminated very close to the front panel RF connection.

“Universal Module Control” through a “no firmware, generic control hardware”design rule for all Xplatform modules.

• site commonality

• equip cost savings

• future proof design

• good performance

Supported Options (per hardware design):

• RF Switches: Multiple Drive Types / Vendors

• Module Control*: TTL or TTL with I2C or only I2C

• Switch Cycle Counter**

* Note: “Stand-Alone” Module USB control is within design capabilities

** Note: “Switch Cycle Counter” option availability to be announced

RF EQUIP

PORTS 1&2

DUT TEST PORTS 1~6BYPASS PORTS

RF EQUIP

PORTS 3&4

RF EQUIP

PORTS 1&2

DUT TEST PORTS 1~6BYPASS PORTS

RF EQUIP

PORTS 3&4

• test

• test

• test• test• test

XPlatformXXXXPlatform Test System *Platform Test System *Platform Test System *Platform Test System *

AC Power (External) Specs:

• 110~230 VAC** / 1A MAX CURRENT (PSU MAX RATING)

• Fused AC Switch / AC Filter

DC Power (Internal) Specs:

• Dual Supply PSU:

• 24VDC @ 1.5A MAX CURRENT

• 5VDC @ 4A MAX CURRENT

• TTL input pull-ups are isolated from PSU 5VDC

• OVER CURRENT PROTECT / AUTO RESET

Chassis Cooling:

• Air intake fan with external removable air filter

• 230VAC** / .080A / 15W

• 80x80mm / 22CFM (mains 110VAC = lower CFM)

• Venting built into equip tray and far location from fan

**110VAC FAN OPTIONAL, PLEASE SPECIFY

Rack Mounting Dimensions:

• Chassis Height Clearance = Standard 2 U (90mm / 3.75in.)

• Chassis Length Clearance = allow .55m

• Chassis Width Clearance = Full Size Rack (483mm / 19in.)

RF Path PerformanceELECTRICAL & MECHANICAL

RF Power Handling:

120W MAX CW to 2GHz, NO HOT SWITCHING

Test Equip Port to DUT Port:

FREQ Parameter Value

690 – 960 MHz Insertion Loss: .9 dBReturn Loss (S22) 33 dB

1700-2200 MHz Insertion Loss: 1.3 dBReturn Loss (S22) 30 dB

2390-2710 MHz Insertion Loss: 1.6 dBReturn Loss (S22) 31 dB

Test Equip Port to Module Bypass Port:FREQ Parameter Value690 – 960 MHz Insertion Loss: .6 dB

Return Loss (S22) 33 dB 1700-2200 MHz Insertion Loss: .9 dB

Return Loss (S22) 27 dB 2390-2710 MHz Insertion Loss: 1.1 dB

Return Loss (S22) 27 dBEquip Port to DUT Port:FREQ Parameter Value690 – 960 MHz Isolation***: 120 dB1700-2200 MHz Isolation***: 115 dB2390-2710 MHz Isolation: 110 dBEquip Port to Module Bypass Port:FREQ Parameter Value690 – 960 MHz Isolation***: 107 dB1700-2200 MHz Isolation***: 104 dB2390-2710 MHz Isolation***: 104 dB

“CORE” Modular ATE Rack Component

Xplatform Team Contact Info:

Haigao Xue, Project Lead, [email protected]

Bruce Lee, Equip & Materials, [email protected]

Stephen Nibblett, Lead Design Engineer, [email protected]

James Lu, Felix Software Development, [email protected]

Shinedy Yu, Software Design Engineer, [email protected]

Zhiguo Feng, Implementation Engineer, [email protected]

Haitao Li, Tech Doc Engineer, [email protected]

ISOLATIONIL PLOTRL PLOT

*ALL DOCUMENTION IN AGILE LOCATED UNDER “DI-X PLATFORM”

*** Shown isolation measurements are typically NWA noise floor, true value may be better according to meas. equipment; results vary

Typical EQUIP PORT to DUT PORT Return Loss

Typical EQUIP PORT to DUT PORT Insertion Loss

Typical EQUIP PORT to DUT PORT Isolation