© 2002 Eaton Corporation. All rights reserved. Powerware 9910-P10 and 9910-P15 High Performance High Reliability & Availability Flexible & Configurable Advanced Communications

Transcript of Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10...

Page 1: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

© 2002 Eaton Corporation. All rights reserved.

Powerware9910-P10 and 9910-P15

High Performance

High Reliability & Availability

Flexible & Configurable

Advanced Communications

Page 2: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Fourth-Generation Online™ topology ensures continuous, clean powerAdvanced Battery Management Plus (ABM Plus™) significantly increases battery lifeExtended Battery Modules (EBMs) prolong backup timesLoad Segments enable scheduled shutdownsTwo-in-One form factor provides versatility2U rack-mount height conserves valuable rack spaceHot-swappable batteries simplify service

Product SnapshotPower Rating: 1000 VA/700 Watt

1500 VA/1050 WattVoltage: 110-127 VacFrequency: 50/60 HzConfiguration: 2U, 19” tower or rackRuntime (in min,): Half/Full load (15/5)Input line cord: 5-15P Number of outlets: 6Options: EBM, SNMP, rack kit

and MultiServer

P10 and P15 Features

Page 3: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

P10 and P15 ApplicationsThe P10 and P15 were specifically designed, engineered and approved for IBM applications

iSeries and AS/400pSeries and RS/6000xSeries and other eServersStorage and networking devices

9910 UPSs are ideal power protection foriSeries family of servers

9406 7025 7043 7044

Page 4: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

P15 with i5 520 Tower

Page 5: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Series 9 Power ProtectionThe P10 and P15 provide double-conversion online power protection from all 9 of the most common power problems that threaten your equipment and data

Power failures High voltage spikes

Power sags Frequency variations

Power surges Switching transients

Brownouts Harmonic distortion

Line noise

Page 6: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Utility Load

Internal Automatic Bypass

Battery

AC to DC Rectifier

DC to AC Inverter

Bi-Directional Power Converter

Filtering

Wide input voltage rangeReduces battery usageReserves batteries for power failures--when you need maximum runtimeExtends UPS service lifeReduces battery replacement costs

EnergyShareUnder extremely poor utility conditions, P10 and P15 models take power from both the utility and batteryReduces battery usageExtends runtime and service life of the battery

P10 and P15 Fourth-Generation Online TopologyTM

Page 7: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Energy Share

EnergyShare range: 120-160V(combined battery and utility)

Battery Power: <120V

Battery Power: >288V

Online voltage regulation: 160-288V

(no battery power needed)

Input Voltage RangeDuring extreme brownouts, the P10 and P15 provide an extra level of protection; the UPS “shares” battery and incoming voltage to continue to provide ±3% of nominal voltage

Page 8: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

B CABM® Technology• Doubles battery

service life by charging only when needed

• Optimizes recharge time

• Does not trickle chargeand starve the electrolyte

• Intelligent microprocessor controlled -Only true & automatic battery check (periodic, controlled discharge) for most accurate advanced failure protection

• Sleep Feature - no unnecessary battery “drain”

Page 9: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Compact DesignThe P10 and P15 packs superior power protection in a sleek, compact design.

19”

17”

3.5”

Page 10: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Informative User Interface

On Button(Start-On-Battery)

Overtemperature

Overload

Load Level/Battery LevelBypass Mode

Alarm Silence/Test Button Off Button

Battery Mode

Normal Mode (UPS On)

Site Wiring Fault

Self-Test

Replace Battery (ABM)

Note: rotate 90° for cabinet configuration

Page 11: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Load SegmentsPower down sequencing of Load Segments

Extends runtime for critical devicesPower up sequencing of Load Segments

Orderly power up of connected devicesScheduled on/off times

Turn off equipment for security and power conservation

Individual control of two Load Segments

Page 12: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

No need to shut down your critical load when replacing batteries

Hot-Swappable Batteries

Page 13: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

UPS and two EBMs

Add EBMs to extend backup time

Extended Battery Modules

Page 14: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Attach EBMs with simple daisy-chain connection EBM Connection

EBM #1 EBM #2

Page 15: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

P10 Battery RuntimesBattery Runtime (in minutes)*

Standard (Std)Watts Internal Batteries +1 EBM +2 EBMs

140 37 271 546

280 19 142 278

490 9 72 156

595 6 59 124

700 5 48 104

Rack height 2 4 6

* Up to 2 EBMs can be connected to the P10. EBM runtimes include P10 internal batteries. Runtime chart provides typical information. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.

Page 16: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

P15 Battery RuntimesBattery Runtime (in minutes)*

Standard (Std)Watts Internal Batteries +1 EBM +2 EBMs +3 EBMs +4 EBMs

280 46 177 331 501 682

490 25 96 180 272 370

595 21 76 142 214 292

700 16 61 115 174 237

875 11 46 87 131 179

1050 8 37 70 106 144

Rack height 2 4 6 8 10* Up to 4 EBMs can be connected to the P15. EBM runtimes include P15 internal batteries. Runtime chart provides typical information. Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.

Page 17: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

P10 and P15 Rear PanelCommunication

Port

X-Slot

Battery Connector

Power Cord with 5-15P

5-15 Receptacles

Network Transient Protector

REPO Port

Page 18: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

REPO/Network Transient Protector

Shut down UPS remotely with REPO port; ideal for rack applications

Network Transient Protector provides protection from “back door” disturbances that travel through phone/network lines

Page 19: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Powerware Extensions Software for IBM Director

Seamless UPS and software integration into IBM Director Network Management System (NMS)Real time monitoring, management and alarm notification of all UPSs in the network: e.g. battery status, battery replacement, load level and metering informationAutomatically launches LanSafe and ConnectUPS Web/SNMP Card applications from within DirectorAvailable on Powerware web FREE-OF-CHARGE

Page 20: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Powerware Software SuiteThe industry’s most comprehensive software bundle, The PowerwareSoftware Suite, is free and included with every P10 and P15.

Software Wizard guides you through software selection and installation. In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite contains the following power management software:• LanSafe™ Network UPS shutdown and monitoring

software• PowerVision® (30-day trial version) UPS performance

analysis and monitoring software

• Foreseer® (demonstration) facility and data center management software

Power Management Software

Page 21: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Software ApplicationPowerware

Extensions for Application LanSafe NetWatch IBM Director

Single pSeries (serial/TTY) non-LPAR

Single pSeries (network) non-LPAR * *

Single pSeries (LPAR) *

Multiple pSeries (non-LPAR) *

Multiple pSeries (LPAR) *

IBM Director Network Device *

* Co-requisite FC 2934 ConnectUPS Web/SNMP network card.

Note: UPS for iSeries applications utilize OS/400 UPS monitoring functions.

Page 22: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Software ComparisonAmbient

Email/ SSL/SSH1 TemperatureApplication Monitoring Shutdown GUI SMTP Security Humidity

LanSafe Yes Yes Yes Yes / Yes No/No No/No

NetWatch - Yes - No/No No/No No/No

ConnectUPS Web/ Yes2 Yes3 Yes Yes / Yes Yes / Yes Yes / Yes4

SNMP Card (FC 2934)1SSL = Secure Sockets Layer. SSH = Secure Shell. 2Via Web Browser, LanSafe or Network Management System (e.g. IBM Director, Tivoli). 3In conjunction with NetWatch software. 4With optional FC 2938 EMP (Environmental Monitoring Probe) device attached.

Page 23: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

Software Solution zSeries iSeries pSeries xSeries Storage Networking

LanSafe

LanSafe and ConnectUPS MultiServer card (IBM FC 2933)

NetWatch and ConnectUPS !

Web/SNMP card (IBM FC 2934) LPARs

Powerware Extensions forIBM Director

NetWatch

ConnectUPS Relay card andAS/400 cable (IBM FC 2936)!Use ConnectUPS Web/SNMP/xHub card, IBM FC 2934 to support LPAR (POWER 4 Chip Set) servers. For pSeries configurations, each LPAR needs a network connection and will install Powerware provided NetWatch or LanSafesoftware.

ConnectivityWhat you need by application

Page 24: Powerware 9910-P10 and 9910-P15oem.powerware.com/ibm-ups/pdf/p10.pdfP10 and P15 Applications The P10 and P15 were specifically designed, engineered and approved for IBM applications

P10 and P15 CollateralAdditional information available at www.powerware.com/ibm

Select your region. Click “Products”, click “9910 Solutions” then click “Powerware pSeries” or “Powerware iSeries”

Powerware UPS Hotline for IBM1-800-925-4426

Materials availableData sheetApplication overview chartProduct presentationDocuments (manuals)