Microspray and Microflow Liquid Chromatography: The Perfect Fit for
Modern LC-MS Bioanalysis
Shane Needham, Ph.D.Co-Founder and Laboratory DirectorAlturas Analytics, Inc.
AlturasAnalytics.com The LC/MS ExpertsTM
100 mL/min, 1.00 mm ID
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9
Time, min
0.0e0
2.0e4
4.0e4
6.0e4
8.0e4
1.0e5
1.2e5
1.4e5
1.6e5
1.8e5
2.0e5
2.2e5
2.4e5
2.6e5
2.8e5
3.0e5
3.2e5
3.4e5
3.6e5
3.8e5
4.0e5
4.2e5
4.4e5
4.6e5
4.8e5
5.0e5
Inte
nsity
10.0 mL/min, 0.300 mm ID
30.0 mL/min, 0.500 mm ID
400 mL/min, 2.00 mm ID
HPLC-MS/MS and MFLC-MS/MS chromatograms from the analysis of a 1.5 µL injection of a 5.00 ng/mL Propranolol solution on an AB SCIEX QTRAP® 5500
Notice band broadening on this first “prototype” MFLC ESI source
AlturasAnalytics.com The LC/MS ExpertsTM
MFLC-MS/MS IN REGULATED BIOANALYSIS
• Can MFLC-MS/MS methods be validated?
• Are the MFLC-MS/MS methods rugged?
• Do the MFLC-MS/MS method results compare well to HPLC-MS/MS methods?
AlturasAnalytics.com The LC/MS ExpertsTM
METHOTREXATE (MTX)
• MW = 454
• Used in treatment of cancer, autoimmune diseases,ectopic pregnancy
•Alturas previously validated a LC-MS/MS method in human plasma from 1-500 ng/mL
•Acetonitrile precipitation
AlturasAnalytics.com The LC/MS ExpertsTM
LC-MS/MS Overlayed Chromatograms (HPLC vs. MFLC) from Bioanalysis of Methotrexate (400 ng/mL) from Human Plasma Using
Eksigent ekspert microLC 200 and a QTRAP 5500
AlturasAnalytics.com The LC/MS ExpertsTM
COMPARISON OF THE LC-MS/MS BIOANALYTICAL VALIDATION OF METHOTREXATE (MTX) FROM HUMAN PLASMA
LC-MS Inter A/P Intra A/P MF
Conv. 105±10.2 *112±13.7 1.02
MFLC 93.3±12.9 *87.1±13.2 1.07
Dynamic range of 1-1000 ng/mL *Includes LLOQ values
AlturasAnalytics.com The LC/MS ExpertsTM
MFLC-MS/MS Chromatograms Overlayed fromBeginning and End of Run of >350 injections of MTX
Extracted from Human Plasma
AlturasAnalytics.com The LC/MS ExpertsTM
QTRAP® 5500 interface plate after approximately 400 extracted human plasma injections from the MFLC system – no switching valve
Slight halo effects
AlturasAnalytics.com The LC/MS ExpertsTM
QTRAP® 5500 interface plate after approximately 150 extracted human plasma injections from the conventional HPLC system – no switching valve
Notice deposits and source contamination
AlturasAnalytics.com The LC/MS ExpertsTM
FUTURE OF LC-MS/MS: COUPLING THE MS SOURCE AND MFLC
Why? Because it works! – simplifies LC-MS
Natural progression of coupling analytical techniques
Less connections-less band broadening
Source is column heater No switching valve needed to
divert waste SAMPLING ADVANTAGE
AlturasAnalytics.com The LC/MS ExpertsTM
“The source is the column, the column is the source”
PicoFuze™ to be inserted into ESI-MS probe
MFLC “column” in the PicoFuze™
QTRAP® 6500 with the Microflow Eksigent ekspert microLC 200 System
PicoFuze™ MS/MS on QTRAP 6500
ESI-MS Probe
AlturasAnalytics.com The LC/MS ExpertsTM
SIGNAL COMPARISON: MTX
0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4Time, min
0.00
5.00e4
1.00e5
1.50e5
2.00e5
2.50e5
3.00e5
3.50e5
4.00e5
4.50e5
5.00e5
5.50e5
6.00e5
6.50e5
7.00e5
7.50e5
8.00e5
8.50e5
9.00e5
9.50e5
1.00e6
Intensity, cps
700 µL/min
PicoFuze™, 12 µL/min
PicoFuze™, 7 µL/min
Notes:•Maximum signal was achieved at 7 µl/min, but the RT and signal was inconsistent at this flow rate.•Optimal signal, run time and robustness were achieved at 12 µL/min
AlturasAnalytics.com The LC/MS ExpertsTM
2.05 2.10 2.15 2.20 2.25 2.30 2.35 2.40 2.45 2.50 2.55 2.60 2.65 2.70 2.75 2.80 2.85 2.90 2.95 3.00Time, min
0.0
1000.0
2000.0
3000.0
4000.0
5000.0
6000.0
7000.0
8000.0
9000.0
1.0e4
1.1e4
1.2e4
1.3e4
1.4e4
1.5e4
1.6e4
1.7e4
1.8e4
Intensity, cps
1st Injection
After ~500 injectionsMTX 400 ng/mL extracted from
human plasma
“Plug and Play”
“First try at full bioanalytical validation on PicoFuze™”
PicoFuze™ in Bioanalysis
AlturasAnalytics.com The LC/MS ExpertsTM
ELECTROSPRAY “SWITCHING VALVE”
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8Time, min
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
Intensity, cps
TIC: from Sample 2 (Methotrexate 1 ng/mL) of ES_Switching.wiff (Turbo Spray IonDrive) Max. 1.3e5 cps.
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0Time, min
0.00
5000.00
1.00e4
1.50e4
2.00e4
2.50e4
3.00e4
3.50e4
4.00e4
4.50e4
5.00e4
5.50e4
6.00e4
6.50e4
7.00e4
7.50e4
8.00e4
8.50e4
9.00e4
9.50e4
1.00e5
1.05e5
1.10e5
1.15e5
1.20e5
1.25e5
Inte
ns
ity, cp
s
2.83
Blank solvent injection showing ESI voltage “turned on” at 2.3 minutes and “turned off” at 3.4 minutes
AlturasAnalytics.com The LC/MS ExpertsTM
≈1990-API III
≈1996-API 3000
≈2001-API 4000
≈2012-API 6500
PicoFuze™ - Future of the LC-MS Source
4.6 mm ID, 1.0 ml/min, split, 100 µL injections
2.1 mm ID, 0.4 ml/min, 40 µL injections
<1.0 mm ID, <100 µl/min, 1-10 µL injections
<0.3 mm ID, <10 µl/min, 1-2 µL injections
But wait, I can improve LLOQ by injecting more on my 2.1 mm ID and I can only inject 1-10 µL on my MFLC!!
AlturasAnalytics.com The LC/MS ExpertsTM
Consumer Driven “Convenience”!
Ease of use is “HIGH PERFORMANCE!”
Inject less volume with better signal for MFLC gives “peace of mind” – SAMPLING
ADVANTAGE
AlturasAnalytics.com The LC/MS ExpertsTM
OTHER BENEFITS OF MFLC-MS/MS
• Reduced source contamination due to less flow and lower injection volumes
• More up time-increased PRODUCTIVITY• No need for a switching valve… -increased EFFICIENCY
• Reduced matrix effects?• Develop methods faster?• Less potential failures?
• Saves solvent – “Goes Green”• 5 mL of organic mobile phase per day at 24/7 operation
(normally 500 mL!) -increased EFFICIENCY
More research needed….
AlturasAnalytics.com The LC/MS ExpertsTM
CONCLUSION: MFLC-MS/MS AND PICOFUZE™ BUZZ WORDS
It works! – “Ease of use is high performance”
“Peace of mind” – More injections per sample due to increased sensitivity – SAMPLING ADVANTAGE
“Plug and play” – minimal optimization for transferring methods from conventional LC or MFLC
Efficient, Productive and Convenient – “Source is the column, column is the source”
Less connections-less band broadening, easier to use Source is column heater No switching valve needed to divert waste
AlturasAnalytics.com The LC/MS ExpertsTM
CONCLUSION
MFLC-MS/MS and PicoFuze™ -MS/MS coupled chromatography and MS will continue to develop
More research needed Expand user base, DATA, DATA, DATA APCI??? Vendors develop HPLC pumps that work for micro and
conventional flows in the same pump Cost of “source column” should compete with cost of
HPLC column
AlturasAnalytics.com The LC/MS ExpertsTM
ACKNOWLEDGEMENTS
Those on Microflow Team at AlturasChad Christianson and Jennifer Zimmer
SCIEX and EksigentGary Valaskovic and entire team at New
Objective Inc.Mike Lee from Milestone DevelopmentNathan Yates from University of PittsburghBrad Ackermann from Eli Lilly
AlturasAnalytics.com The LC/MS ExpertsTM