PowerPoint 簡報 - nuvola.bg · Inspur Confidential –For Use Under NDA Only i9000 Compute Blade...

11
Inspur Confidential – For Use Under NDA Only i24 i9000 HAHD (High Availability High Density) Density enhanced 33% over the general servers, also reduced power consumption 30% of general server structure Separate IO Expansion Module Pioneered to support separate IO Expansion Module for direct connectivity to the back of the unit and s Accelerate to Increase Business Agility Flexible storage options to quickly enable extended local capacity and cost effective boot disk storage, supporting SAS/SATA/SSD/NVMe converged storage Converged architecture blade system, i9000, fully supports the mainstream compute nodes and network switches, allowing the customers scale business performance and securely drive traditional and Hybrid IT workloads across a converged infrastructure Aug. MP

Transcript of PowerPoint 簡報 - nuvola.bg · Inspur Confidential –For Use Under NDA Only i9000 Compute Blade...

Inspur Confidential – For Use Under NDA Only

i24

i9000

HAHD (High Availability High Density)Density enhanced 33% over the general servers, also reduced power consumption 30% of general server structure

Separate IO Expansion ModulePioneered to support separate IO Expansion Module for direct connectivity to the back of the unit and s

Accelerate to Increase Business AgilityFlexible storage options to quickly enable extended local capacity and cost effective boot disk storage, supporting SAS/SATA/SSD/NVMe converged storage

Converged architecture blade system, i9000, fully supports the mainstream compute nodes and network switches, allowing the customers scale business performance and securely drive traditional and Hybrid IT workloads across a converged infrastructure

Aug. MP

Inspur Confidential – For Use Under NDA Only

I9000 (Chassis)

Form Factor 12U, 440mm (D)

Compute Blade Up to 16 half-width compute blades

IO Expansion Module(IO Box)

Up to 8 standard IO Expansion Module (IO Box)Each module supports PCI-E x8 slots, HHHL

Switch Module Up to 4 FH switch modules

Cooling Module Up to 10 FAN modules

Management Module

Support two chassis management modules, 1+1 redundancy and cascade management function. Black box function, record the fault information Fast fault inquiry and location of power failure and the fast recovery operation, to improve the

stability of system. Remote management, information monitoring, log management, automatic alarm and network

installation functions of unified interface for blade and mainframe box and the remote start, monitoring, locking, closing and logout functions of the compute blade.

Redfish IPMI 2.0 KVM Over LAN/KVM Over IP supported Serial over LAN (SOL) Virtual Media Over LAN (Virtual USB/DVD and Drove Redirection)

i24 M5

i9000 Product Spec.Aug. MP

Inspur Confidential – For Use Under NDA Only

5

6

7

8

1

2

3

4 1 2 3 4

1

2

3

4

5

6

7

8

9

i9000 Front/Rear View

Half-wide BladeMax. support 16pcs(NX5460M5)

PSU ModuleDefault 3pcsMax. 6pcsN+N, N+M Redundancy

Cooling ModuleDefault 4pcs, max. support 10pcs

1+1 80x38 FAN

Switch ModuleMax. support 4pcs(Full Height)

PDUChassis Management ModuleDefault 1pc, max. 1+1

Blade 1

Blade 8

Blade 16

Blade 9

3000W 100-240VA 80Plus

1 8

1 4

IO Expansion ModuleMax. support 8pcs

10

A B C D E F

Front View Rear View

Aug. MP

Inspur Confidential – For Use Under NDA Only

i9000 Compute Blade

Blade 1

Blade 8

Blade 16

Blade 9

NX5460 M5

Form Factor Half-wide compute blade, 55mm(H)× 214mm(W)× 524mm(D)

Processor(s) Intel® Xeon® Scalable, two-socket, support max. 28 cores

Chipset Intel ® C620 series chipset

Memory

12 DIMM slots per processor, 6 channels per processor, 2 DIMM per channelRDIMM, LRDIMM and NVDIMMMax. Capacity (RDIMM): 768GB, 24x 32GB @2666 MHzMax. Capacity (LRDIMM): 3.0TB, 24x 128GB @2666 MHz

PCI SlotsSupport dedicated PCI-E x8 for RAID Mezz. card and PCI-E x16 for IO Expansion Module (IO Box)Support two PCI-E x16 for network Mezz. card (one from the second processor)

Internal Storage2x 2.5” drive, support SAS/SATA/U.2 NVMeInternal 2x M.2 SATA/PCI-E

Ethernet Integrated LAN controller; up to 2x 1GbE

Aug. MP

Inspur Confidential – For Use Under NDA Only

Configuration1 Configuration2

1x PCI-E x16 Slot 2x PCI-E x8 Slots

Support two FHFL PCI-E cardsSuggestion: GPU

Support four FHFL PCI-E CardsSuggestion: MIC, FPGA, PCI-E SSD

i9000 Compute Blade Top View

IO Module

IO Module Connecting Cable(PCI-E x16 signal)

Air Baffle

IO Module

IO ModuleConnecting Cable(PCI-E x16 signal)

Power Board

Compute BladeWith PCI-E Extension Node

Aug. MP

Inspur Confidential – For Use Under NDA Only

i9000 Compute Blade Top View

Compute BladeWith Storage Node

RAID Mezz. Card

HDD0,1

HDD2,3

HDD4,5

HDD6,7

HDD8,9

HDD10,11

HDD BP

Support 12pcs of 2.5” SAS/SATA/SSDMax. support quantity is 14pcs (12+2)

Aug. MP

Inspur Confidential – For Use Under NDA Only

i9000 Compute Blade

TypeRotation

per secondCapacity

2.5 SAS

7.2K 1TB/2TB

10K 300G/450G/600G/900G/1.2TB/1.8TB

15K 300G/450G/600G

2.5 SATA 7.2K 1TB/2TB

HDD

Type Capacity Supplier

SATA SSD 150G Intel

SATA SSD 240G Intel/Samsung

SATA SSD 400G Intel

SATA SSD 480G Intel/Samsung

SATA SSD 800G Intel

SATA SSD 960G Intel/Samsung

SATA SSD 1.2TB Intel

SATA SSD 1.6TB Intel

SATA SSD 3.8TB Samsung

SSD

Type Capacity Supplier

PCI-E SSD 400G Intel

PCI-E SSD 800G Intel/Memblaze

PCI-E SSD 1.2TB Intel/Memblaze

PCI-E SSD 1.6TB Intel/Memblaze

PCI-E SSD 2TB Intel

PCI-E SSD 2.4TB Intel

PCI-E SSD 3.2TB Intel/Memblaze

U.2 NVMe SSD 400G Intel

U.2 NVMe SSD 450G Intel

U.2 NVMe SSD 800G Intel/Samsung

U.2 NVMe SSD 1.2TB Intel/Memblaze

U.2 NVMe SSD 1.6TB Memblaze/Samsung

U.2 NVMe SSD 1.8TB Intel

U.2 NVMe SSD 2TB Intel

U.2 NVMe SSD 2.4TB Memblaze

U.2 NVMe SSD 3.2TB Memblaze/Samsung

Aug. MP

Inspur Confidential – For Use Under NDA Only

i9000 Switch Module

1Gb/10Gb Multi-Layer Converged

Switch Module

10Gb Converged Switch Module

10Gb FCoESwitch Module

16Gb FC SAN Switch module

Uplink Ports

8x RJ458x 10GbE SFP+2x 40GbE QSFPSupport the stackingEach port can support to convert to 4x 10GbE and 1× RJ45 for management.

16x 10GbE SFP+4x 40GbE QSFPSupport the stackingEach port can support to convert to 4x 10GbE and 1× RJ45 for management

16x 10GbE SFP+4x 40GbE QSFPSupport the stackingEach port can support to convert to 4x 10GbE and 1× RJ45 for management

16x SFP+ FC interfaces, 4/8/16Gb rate supportedIt can be used as F-ports and E-ports (extended port), or used as N-ports in the access gateway mode.1× RJ45 for management

DownlinkPorts

16x 1GbE links connect to the 1GbE LOM on the compute blade.32x 10GbE links connect to the 10GbE Mezz on the compute blade.

16x 10GbE links connect to 10GbE Mezz on the compute blade.

16x 10GbE links connect to 10GbE Mezz on the compute blade.

32x full duplex 16Gb FC interfacesDownlink port: F-ports.

Switching Function

Standard L2 and L3 switching (IPv4&IPv6).Data center functions

Standard L2 and L3 switching (IPv4&IPv6).Support FCoE (16 uplink ports) and FC (8 ports in 16 uplink ports)Data center functions

Standard L2 and L3 switching (IPv4&IPv6).Support FCoE (16 uplink ports) and FC (8 ports in 16 uplink ports)Data center functions

Standard L2 and L3 switching (IPv4&IPv6).Support FCoE (16 uplink ports) and FC (8 ports in 16 uplink ports)Data center functions

FAN Two hot-swappable fans Two hot-swappable fans Two hot-swappable fans Two hot-swappable fans

FSM16488-12EESM10488

ESM1048xESM1048YFSM16488-12FSM16488-24

Aug. MP

Inspur Confidential – For Use Under NDA Only

i9000 Switch Module

Management Function

– SNMP v1/v2/v3, Telnet, Console, MGMT, WEB, RMON, SSHv1/v2, FTP/TFTP file upload and download management, support the NTP clock, Syslog, SPAN/RSPAN and IPFIX flow analysis.

– Can carry out the network configuration and FW upgrading by the system management module.

– Provide the switch monitoring and management interface (temperature, voltage, log and alarm information). The alarm information can be informed to the management module.

– Support the boot, shutdown and restart of the switching module by the management module.

– Can configure the switching module by the management module (two modes, the command line and management interface).

Aug. MP

Inspur Confidential – For Use Under NDA Only

i9000 IO Expansion Module (IO Box)

1

2

3

4

5

6

7

8IOBOX IOM3082

PCI Slots Support two PCI-E x8 slots, HHHL

Aug. MP

Inspur Confidential – For Use Under NDA Only

PSUQuantity

RedundancyHalf-wide Blade

Quantity

3 (A,B,C) 2+1 9

4 (A,B,C,D)2+2 9

3+1 15

5 (A,B,C,D,E)4+1 16

3+2 15

6 (A,B,C,D,E,F)

3+3 15

4+2 16

5+1 16

i9000 Redundancy

Cooling Module QuantityHalf-wide Blade

Quantity

4 (1,2,3,4) 1-3

5 (1,2,3,4,5) 4-8

8 (1,2,3,4,5,6,7,8) 9-11

10 (1,2,3,4,5,6,7,8,9,10) 12-16

PSU Redundancy

FAN Redundancy

1

2

3

4

5

6

7

8

9

10

A B C D E F

Aug. MP