Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Panelview Plus 7 New Features & Functions
plus Mobility
VI01
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Keith Krings – Werner Electric
Tom Steffen – Rockwell Automation
Presenters
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
• VI02 – Intro to Factory talk View ME 8.0
lab
• AD06 – Studio 5000 Best Practices
• AD07 – Studio 5000 New Features and
Benefits
• AD09 – Intro to Logix Hands-on lab
• AD10 – Logix Integration Hands-on Lab
Related Sessions
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Agenda
FTViewME 8.0 Features
Panelview Plus 7 Models and Features
Remote Access Options
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Portfolio
PanelView Classic PanelView Standard
PanelView Enhanced
PanelView Plus
PanelView Plus
Compact
PanelView Plus 6
…
An evolution of graphic terminals since 1989
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Portfolio
PanelView Classic PanelView Standard
PanelView Enhanced
PanelView Plus
PanelView Plus
Compact
PanelView Plus 6
… PanelView
Plus 7
Since 1989
PanelView Plus 7 extends the portfolio
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7
• Extends offering and
functionality –PanelView Plus 7 standard
model
–PanelView Plus 7 performance
model
• New form factor –Common to future IA operator
interfaces
–Adapter plates for PanelView
Plus 6 or PanelView Plus retrofit
Features
Widescreens
New Display Sizes
ATEX (select models)
Ethernet with embedded switch (DLR)
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Models
Performance Standard
6.5”, 9”W, 10.4”, 12”W, 15”, 19”
Low profile painted aluminum bezel
Resistive touch screen with keypad
options
Ethernet with embedded switch
X86 processor
1 GB Flash Memory / 512 MB RAM
Windows CE 6.0 extended features
DC and AC power options
Targeted at larger / complex applications
4.3”W, 5.7”, 6.5”, 9”W, 10.4”, 12”W, 15”
Low profile plastic bezel
Resistive touch screen
Ethernet with embedded switch and
single Ethernet option on 4.3” to 10.4”
ARM processor
512 MB Flash Memory / 512 MB RAM
Windows CE 6.0 standard features
DC powered
Targeted for simpler / smaller applications
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Features
Product Features PanelView Plus 7 Standard model
PanelView Plus 7 Performance model
FactoryTalk Machine Edition Y Y
ViewPoint Y Y
Memory RAM / Flash 512 MB / 512 MB 512MB / 1 GB
PDF Viewer Y Y
Active X Controls (Email, DataStorePlus, Recipe) Y Y
Remote Terminal Control (Based on VNC) Y Y
FTP Server Y Y
MPEG Video playback N Y
Microsoft Office Viewers N Y
Microsoft Internet Explorer N Y
Remote Desktop Services N Y
Ethernet Connectivity Y (Single Only) Y (DLR Only)
CPU ARM 1Ghz x86 1.6Ghz
Screen Sizes 4.3”-15” 7”-19”
Application Sizes 1 Controller, 25 Screens,
200 Alarms Larger Applications
Catalog numbers 2711P-xxxxx8S 2711P-xxxxx9P
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Ethernet Connectivity
PanelView Plus 7 Performance line comes with an embedded switch (DLR).
PanelView Plus 7 Standard version include an embedded
Ethernet Port.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Features
• Communication options on the PVP7:
– Ethernet Only
– Standard 4”-15” Single Port
– Performance 7”-19” DLR
• Screen resolutions for PanelView Plus 7
Standard and Performance are the same.
Size Resolution X Y
4” Wide WQVGA 480 272
6” VGA 640 480
7” VGA 640 480
9” Wide WQVGA 800 480
10 SVGA 800 600
12” Wide
WXGA 1280 800
15” XGA 1024 768
19” SXGA 1280 1024
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 SD Card Data Storage
Quick and Easy Terminal Copy & Restore
Use an SD card to quickly create copies of a terminal to reduce your time to market or restore a terminal.
• Operating system
• Network configuration and terminal settings
• FactoryTalk® View Machine Edition (ME) runtime file
• Datalogs and Recipe files
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Release Schedule
Released
Standard Models
• 4”-10”
• Single Ethernet
• Associated Accessories
Release 2 – Q3 / 2015
Additional Standard Models
• 12” and 15” single Ethernet
Performance Models
• 7” – 19” all DLR
• Associated accessories
Adapter Plates
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Standard
Decrease time to market… Increased screen resolution…
Standard Model – Single Ethernet
– Machine Builder Focus
– Sizes: 4”-10” / 12”-15” Summer 2015
– Single Ethernet
– Touch Screen
– Low Profile, Composite Bezel
– FactoryTalk View Machine Edition -
supporting MER files back to 3.2
– 5 Catalogs – Allen-Bradley Branded
– 5 Catalogs – No Branding
Widescreens ….. New Display Sizes….. ATEX Certifications …..
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Standard Features & Benefits
Standard
4.3”W, 5.7”, 6.5”, 9”W, 10.4”, 12”W, 15”
Low profile composite bezel
Resistive touch screen
Single port Ethernet
ARM processor
512 MB Flash Memory / 512 MB RAM
Windows CE 6.0 standard features
DC powered
Removable Battery
Targeted for simpler / smaller applications
ATEX Certification, Class 1 Div. 2
Machine Builder Focused
• OEM Optimized Design
• Expanded Processing Power
• Composite bezel
• Competitive Solution
• More screen options
• Greater resolution
• Wide screen options
• Application Size Limits
• 1 Controller
• ≤25 Screens
• ≤200 Alarms
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Standard Release 1
Accessories
Mounting Levers - 2711P-RMCS
SD Card Covers - 2711P-RCKS
DC Terminal Blocks - 2711P-RTBDSP
Protective Overlays - 2711P-RGTxS (x is terminal size)
Battery Covers - 2711P-RYKS
Catalog Number PanelView Plus 7 Standard EOI Description
2711P-T4W21D8S 4” WQVGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T6C21D8S 6” VGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T7C21D8S 7” VGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T9W21D8S 9” WVGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T10C21D8S 10” SVGA TFT color, Touch, DC powered, Single Ethernet port
2711P-T4W21D8S-B 4” WQVGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel
2711P-T6C21D8S-B 6”VGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel 2711P-T7C21D8S-B 7” VGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel
2711P-T9W21D8S-B 9” WVGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel
2711P-T10C21D8S-B 10” SVGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Standard Anatomy
Mobile ready with VNC support and FactoryTalk Viewpoint
ATEX and UL Class 1, Div 2
for demanding environments
With the embedded PDF Viewer, show:
• User Manuals
• Installation Manuals
• SOPs (Standard Operating Procedures)
Faceplates and Add-on Instructions can
save 50 – 90% of complex screen development time
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 6 Compact vs
PanelView Plus 7 Standard display
sizes
4.3 in.
wide
(480x272)
5.7 in.
(640x480)
6.5 in.
(640x480)
9.0 in.
wide
(800x480)
12.1 in. wide
(1280x800)
10.4 in.
(800x600)
15.0 in.
(1024x768)
3.5 in.
(320x240)
5.7 in.
(320x240)
10.4 in.
(640x480)
More Screens Sizes and Greater Resolution to Chose From.
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
PanelView Plus 7 Standard Anatomy
SD storage card slot for data
storage and terminal replication
USB Ports for quick upload
and download to the terminal
New installation clamps provide
fast and simple terminal
installation and removal
Embedded Ethernet port for
connectivity from the machine to the enterprise
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
FactoryTalk View ME v8.0
• Each project has its own private security configuration
• Restore a project (MER/APA) without overwriting any other project’s security configuration
Design-time security
• Allows panel to authenticate with Server 2008/2012 domains
• Requires LDAP support to be enabled in end-user’s domain
Updated Domain authentication
• Add and delete FactoryTalk users during runtime
• Change user’s group membership during runtime
Runtime user management
• Windows 8 and Windows Server 2012 Support
• PanelView 7 Support
Compatibility
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Feature Cheat Sheet
• Support New PanelView Plus 7
• Simplified project maintenance
• Added domain authentication options
• Enhanced Login button provides domain field
• Manage security configuration within a running application
• Improved audit trail
• New error-proofing features
• Changes to Security Codes
• Installation enhancements
• Compatibility with additional OS
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Simplified Project Maintenance
• Improved handling of multiple FTView
Machine Editions applications on same PC
– Each project has its own private security
configuration
– Allows user to restore a project (MER/APA)
without overwriting any other project’s security
configuration
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
How Security Works Before v8.0
Public Local FactoryTalk Directory
Users & Groups
Project A
Project B
RSLinx Config.
Project C
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
How Security Works In v8.0
Project A
Private Local
FactoryTalk Directory
Users & Groups
RSLinx Config
Project B
Private Local
FactoryTalk Directory
Users & Groups
RSLinx Config
Project C
Private Local
FactoryTalk Directory
Users & Groups
RSLinx Config
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design-time Security Changes
What Do They Mean To Me?
• Each ME application’s security configuration is unique
• No need to be ‘careful’ when restoring MER or APA – No more prompt to restore FTDir, or not, when restoring an
APA/MER
• Must manage security (user, groups, policy) from ME Project Explorer tree – FTAdmin does not work with or recognize the private local
FTDir associated with each ME application
• Must use a ‘template’ project to have a common set of users & groups – Use App Mgr to copy ‘template’ to new project before starting
– Cannot move, copy, or backup/restore users & groups between projects
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Design-time Security Changes
What Do They Mean To Me?
• When creating a new pre-8.0 MER, the system converts from the private
local FTDir to the necessary format; no restrictions
• V8.0 ME Station, on a PC, continues to use the public local FTDir
• Slight delay working with applications (new, open, rename, copy, etc.)
– Delays optimized for New Application and Open Application operation
– Typical delays are < 135% of current 7.0 performance
• Ex a 7.0 operation that took 30s, it might now take ~40s
• Application Manager Copy, Rename, and Delete can only operate on
applications that have been opened with FTView Studio v8.0
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Added Domain Authentication Options
• Support Windows Server 2008 & 2012 Domain authentication
– Requires domain enables LDAP support
– Requires additional configuration in ME Station for LDAP
– Can use LDAP or LDAP Over SSL
• LDAP Over SSL encrypts the user credentials
• LDAP over SSL requires certificate to be moved (manually) to terminal
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Login Button enhancements
support Domain
• Added optional DOMAIN field to login button
• At run-time DOMAIN field can be
– Fixed text
– User entered
– Content of a tag
• HMI designer can control
– Visibility of DOMAIN field
– Editability of DOMAIN field
– Tie DOMAIN field to a tag via Connection property
– Obscure user name (‘#’ shown instead of characters)
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Domain Authentication Changes
What Do They Mean To Me?
• Supports Windows Server 2008 & 2012 Domain authentication
• Existing application will work in Windows 2008/2012 domains, unchanged – LDAP configuration applies to the terminal, not the application
– Domain authentication is handled by FTSP on the terminal • Application asks FTSP to authenticate the user with the provided
credentials; FTSP determines which calls Windows or LDAP calls to make
• When authenticating the system will ALWAYS attempts Windows authentication API calls before LDAP – System switches to LDAP if Windows Authentication API fail
• When using LDAP over SSL a certificate must be manually moved to the terminal using a USB stick or SD card
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Manage User Security @ Run-time
• Modify security configuration in a running ME application – Change any FactoryTalk user’s password
– Add FactoryTalk or Windows-linked user, or Windows-linked group
– Delete FactoryTalk or Windows-linked user, or Windows-linked group
– Change FactoryTalk or Windows-linked user’s, or Windows-linked group, group membership
– Change FactoryTalk user’s account properties
– Change logged in FactoryTalk user’s password
– Enable / Disable FactoryTalk user
– Unlock FactoryTalk user
• Security configuration changes persisted in the MER – Don’t lose change when upload and restore the MER
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Improved Error-proofing
• When building MER for a PanelView Plus terminal, system warns if a shortcut uses an unsupported network, Ex. RIO
• When loading MER on PanelView Plus terminal will warn if
– MER project resolution (size or aspect ratio) does not match physical terminal
– MER contains shortcut(s) using network physical terminal does not support, Ex. PanelView Plus 7 and DH+
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Runtime Security Enhancements to
Security Codes (A-P)
• In v8.0 ME Station, PanelView Plus or PC, at run-time, if a user is a member of
more than one A-P configuration, then the user’s effective Security Code A-P
permissions will be the most restricted set; previous versions granted the most
lenient effective Security Code A-P permissions
Example
– Bob, a FactoryTalk user, is a member of two FactoryTalk groups, Group1 and
Group2
– In the Design-time application using FactoryTalk View Studio, Runtime
Security is configured as shown ; only codes A-D are shown for simplicity
– Bob’s effective Security Codes in the running application are shown
below.
Runtime Security Configuration A B C D
Group1 X X X
Group2 X X X
Effective Security Codes A B C D
FactoryTalk View 7.0, and earlier X X X X
FactoryTalk View 8.0 X X
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Runtime Security Enhancements to
Security Codes (A-P)
• How can a user be a member of more than one A-P Security Code configuration – FactoryTalk or Windows-linked User explicitly configured in
Runtime Security more than once
– FactoryTalk or Windows-linked User is a member of more than one configured FactoryTalk Groups in Runtime Security
– FactoryTalk or Windows-linked User is a member of one or more FactoryTalk Group(s) configured in Runtime Security and the user is also explicitly configured in Runtime Security
– Windows-link User is a member of a Windows-linked group, the Windows-linked group is a member of more than one FactoryTalk Groups configured in Runtime Security
– Windows-linked User is a member of a Windows-linked group, the Windows-linked group is a member of one or more FactoryTalk Group(s) and the Windows-linked user is also explicitly configured in Runtime Security
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
More Easily Manage Alarms
• Resizable alarm editor
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
More Easily Manage Alarms
• Resizable alarm editor
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Improved Application Manager
Workflow
• Application Manager behavior changed to return to starting step when an operation completes so user can immediately initiate next operation
• Application Manager now allows the user to overwrite existing backup (APA) files when creating a backup file
• Application Manager now allows the user to overwrite an existing project when restoring a backup (APA) or runtime (MER) file
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Better Auditing
37
• Audit messages reflect ‘old’ data and ‘new’
data
• FTAsset Centre
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Installation Improvements
• Unattended Installation mode
– Supports an ‘Answer File’ to pre-configure
installation options
– Can be used with Application Management
software (Ex. Altiris)
• Optimization of DVD content to reduce
download size
• Inhibit install on unsupported OS
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Additional Platforms and
Operating System Support
• Windows Operating Systems
– Windows 8 Professional 7 Enterprise (32- and 64-bit)
– Windows 8.1 Professional 7 Enterprise (32- and 64-bit)
– Windows Server 2012 Standard (64-bit)
– Windows Server 2012 R2 Standard (64-bit)
• PanelView Plus Platforms
– PanelView Plus 6 Compact 1000
– PanelView Plus 7 Standard
– PanelView Plus 7 Performance
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
Removing Platforms and
Operating System Support
• FactoryTalk View 8.0 is the LAST release to support v 3.2 and v4.0 MER – Using release after v8.0, it is not possible to create
v3.2 or v4.0 MER
– Using release after v8.0, it is not possible to execute v3.2 or v4.0 MER
– Using release after v8.0, it IS possible to open and convert legacy applications the newer format
• FactoryTalk View v8.0 is the LAST release to support – Windows XP [any edition or SP]
– Windows Vista [any edition or SP]
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
• Would productivity increase by allowing your operators remote
access to terminal data from a remote location?
– New Server Enablement on PanelView Plus 7 supports two VNC client
connections
– Variety of remote connection technologies, including terminal-to-terminal
communication
PanelView Plus 7 Mobility Options
Knowledgebase Note 466394
Technology
FTP
VNC
ViewPoint
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
What if you needed info quickly : – Unit count – Read alarm data – Review trend data… etc
But you were no where near your computer or the line?
Technology Tools to Enhance
Experience
Cloud
Motorola ET1
Client “Server”
VNC
Stationary
View
Extendable
View
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.
• Sessions
• VI02 – Intro to Factory talk View ME 8.0 lab
• AD06 – Studio 5000 Best Practices
• AD07 – Studio 5000 New Features and Benefits
• AD09 – Intro to Logix Hands-on lab
• AD10 – Logix Integration Hands-on Lab
• Tradeshow
• Solution Area 3 – Process & Connected Enterprise
Where can I learn more?