PGE bv | Powergear Europe | [email protected] www.powergear.eu | +31 76 3031 405 | Breda | The Netherlands Driver designed and manufactured in Europe SAFETY AMBIENT EMI PROTECTIONS DIMMING AP/PWM controlled by DALI signal. Minimum dimming level 1%. AM dimming from 100% to 25% load. PWM dimming from 25% to 1% load. Against input over voltages from mains (according to EN61547) up to 2KV N-L, 4KVN-GND, 4KV L-GND. Against short circuit and open circuit. Thermal protection (C.5.e from EN613471). According to EN55015. Tc = 75ºC. Tc life 50000h = 75ºC. Case IP00 Hi-Pot-Test: 3,75 kV, 100% for 2 sec. Nominal: 220-240 Vac±10% 50/60Hz. ∙ 0,5mm² cables, double insulated BLUE, single isolated BROWN for L-N inputs. ∙ Max Input Current: 0,20A. ∙ Power factor: 0,97. ∙ Harmonic content of mains current: according to EN61000-3-2-2. ∙ Inrush current: 5A. SELV insulation on output. ∙ Terminal block, up to 1x0,2 0,5mm². ∙ Selection of current and voltage output through DIP-switch (see table). ∙ Max output power and current precision @220-240Vac: ∙ Max. Output voltage: 59VDC. ∙ Efficiency @full-load: 86%. RIPPLE FREE

Transcript of Powergear Leaflet EngelsLeaflet+Engels+-+WEB.pdf · SAFETY ∙ Hi-Pot-Test: 3,75 kV, 100% for 2...

  • PGE bv | Powergear Europe | [email protected] www.powergear.eu | +31 76 3031 405 | Breda | The Netherlands

    Driver designed andmanufactured in Europe

    SAFETY

    AMBIENT

    EMI

    PROTECTIONS

    DIMMING AP/PWM controlled by DALI signal. Minimum dimming level 1%. AM dimming from 100% to 25% load.

    PWM dimming from 25% to 1% load.

    Against input over voltages from mains (according to EN61547) up to

    2KV N-L, 4KVN-GND, 4KV L-GND.

    Against short circuit and open circuit.

    Thermal protection (C.5.e from EN613471).

    According to EN55015.

    Tc = 75ºC.

    Tc life 50000h = 75ºC.

    Case IP00

    Hi-Pot-Test: 3,75 kV, 100% for 2 sec.

    ∙ Nominal: 220-240 Vac±10% 50/60Hz.

    ∙ 0,5mm² cables, double insulated BLUE,

    single isolated BROWN for L-N inputs.

    ∙ Max Input Current: 0,20A.

    ∙ Power factor: 0,97.

    ∙ Harmonic content of mains current:

    according to EN61000-3-2-2.

    ∙ Inrush current: 5A.∙ SELV insulation on output.∙ Terminal block, up to 1x0,2 0,5mm².∙ Selection of current and voltage output through DIP-switch (see table).∙ Max output power and current precision @220-240Vac:

    ∙ Max. Output voltage: 59VDC.

    ∙ Efficiency @full-load: 86%.RIPPLEFREE

    C

    M

    Y

    CM

    MY

    CY

    CMY

    K

    1901230 Powergear Leaflet - PRO-T6700 [Drukklaar].pdf 2 04/02/2019 16:03:54

  • SAFETY ∙ Hi-Pot-Test: 3,75 kV, 100% for 2 sec.

    AMBIENT

    EMI

    PROTECTIONS

    ∙ Tc = 80°C.

    ∙ Tc life 50000H = 80°C.

    ∙ Case IP00.

    ∙ According to EN55015.

    ∙ Against input over voltages from mains (according to EN61547) up

    to 2KV N-L, 4KV N-GND, 4KV L-GND.

    ∙ Against short circuit.

    ∙ Thermal protection (C.5.e from EN61347- 1).

    ∙ Nominal: 220-240 Vac±10% 50/60Hz.

    ∙ 2x Terminal block 0,2...0,75mm².

    ∙ Max Input Current: 0,25A.

    ∙ Power factor: 0.97.

    ∙ Harmonic content of mains current:

    according to EN61000-3-2.

    ∙ Inrush current: 5A. ∙ SELV-Insulation on output.∙ Terminal block, up to 1 x 0,2...0,5mm².∙ Selection of current and voltage output through Dip-switch.∙ Max output power and current precision @ 220-240Vac:

    ∙ Max. Output voltage: 59VDC.∙ Efficiency @full load: 86%min.

    ∙ EN 61347-1; EN 61347-2-13; EN 61547;

    EN 55015; EN 61000-3-2;

    DIN VDE 0710 teil 14.

    ∙ KEMA KEUR; ENEC 05 Pending.