POWER TRANSMISSION Mechanical load characterization.
-
Upload
gabrielle-lindsey -
Category
Documents
-
view
220 -
download
1
Transcript of POWER TRANSMISSION Mechanical load characterization.
![Page 1: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/1.jpg)
POWER TRANSMISSION
Mechanical load characterization
![Page 2: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/2.jpg)
MECHANICAL LOAD CHARACTERIZATION
A mechanical load may be decomposed in:
• an apparatus that has to be “moved” said apparatus load
• a transmission mechanism (gear train, gearbox) said transmission load
• the rotor of the motor said rotor load
Each of these parts has its own dynamic and static characteristic.
![Page 3: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/3.jpg)
![Page 4: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/4.jpg)
The apparatus load can be divided into two classes:
Dissipative load when energy supplied by the actuator is used to provide work e.g. tool machining like turning, milling etc. or lost for friction compensation e.g. industrial mixers or fans, rail drive, lifting.
Inertial load when energy supplied by the actuator is used to accelerate and/or to brake the load e.g. robots, high speed automatic positioning devices, metropolitan wheel drive
![Page 5: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/5.jpg)
Load torque is usually widely variable during the appartus operations
Friction torque is function (proportional) of velocity
Moment of inertia almost constant
Dissipative load is characterized by the load torque and/or friction torque
![Page 6: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/6.jpg)
Moment of inertia with relevant variations respect a nominal value
High speed
High accelerations (relevant jerk)
Dissipative torque may be considered a disturb of the system
Inertial load is characterized by the velocity and moment of inertia
![Page 7: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/7.jpg)
Cm= J dω/dt + Cv + Ca + Cc
Ca static & dynamic (Coulomb) friction torqueCc load torque (and Power)
Cv = Fv · ω viscous friction torque (Bω)
J dω/dt = inertial load (Jα)
![Page 8: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/8.jpg)
DYNAMIC LOAD CHARACTERIZATION
![Page 9: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/9.jpg)
VERY SLOW DYNAMIC : J dω/dt << Cv + Ca + Cc
![Page 10: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/10.jpg)
SLOW DYNAMIC : J dω/dt < Cv + Ca + Cc
![Page 11: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/11.jpg)
FAST DYNAMIC : J dω/dt > Cv + Ca + Cc
![Page 12: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/12.jpg)
VERY FAST DYNAMIC : J dω/dt >> Cv + Ca + Cc
![Page 13: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/13.jpg)
POWER TRANSFER
For a gear train the load inertia can be reduced by a factor (N1/N2)² thus making the torque requirements of the actuator lower than driving the load directly.
Similarly, the inertia seen by the lead screw is also controllable by its coupling ratio
WHAT COUPLING RATIO SHOULD BE CHOSEN?
![Page 14: POWER TRANSMISSION Mechanical load characterization.](https://reader036.fdocuments.in/reader036/viewer/2022062318/5515468755034685568b50c4/html5/thumbnails/14.jpg)
If the desired characteristic of the transmission is a speed or torque change ->
Coupling ratio chosen per the design specification
To minimize the energy dissipated by the actuator (electric motor) ->
Coupling ration chosen on the principle of an INERTIA MATCH
This concept uses the coupling ratio to make the reflected load inertia equal to the inertia of the motor; for a speed-reducing gear train one should choose the ratio N1/N2 by the formula:
N1/N2 = √J2/J1
Similarly, an optimal pitch for a lead screw which minimizes the energy dissipated
P= 2∏ √J1/M