Power plant DCS migration completed with minimal impact ...
Transcript of Power plant DCS migration completed with minimal impact ...
“The migration approach offered by Invensys Operations Management showed that an alternative to the existing vendor’s upgrade solution was a viable option.”
Hugh Ferguson, C&I Engineer & DCS Upgrade Project Manager, Keadby Power Station
Invensys Powers UK Electricity Demand
Goals•ThecompanyneededtoaddresstheobsolescenceofitsexistingDCSandtoprovideanexpandablesolutiontoextendtheworkingservicelifeofitsKeadbyPowerStation
•Thevendorneededtodeliverthetotalupgradesolutionintimeforaplannedmajorshutdownandinparallelwithotherplantprojects,withminimalcommissioningtime
Challenges•Incompleteloopdrawings,fadedconductoridentsandtheriskofhumanerrorduringI/Ochange-outwereconsideredsignificantupgradeobstacles
•Limiteddocumentationavailableonexistingsoftwareapplicationspresentedsoftwaremigrationandtestingdilemmasfortheprojectteam.
Solutions and Products•InFusion™EnterpriseControlSystem(thefirstmajorInFusionsolutionintheUK)
•Foxboro®I/ASeries®DistributedControlSystem
•SimSci-Esscor®ROMeoOnlinePerformanceSuite
•SimSci-EsscorDynamicSimulationSuite
Results•TheInvensyssolutionwasdeliveredontimefortheplannedoutageandwithintheSSEbudgetfortheproject.
•Theupgradeaddressedboththeobsolescenceandexpandabilityissues.
•Plantpersonnelrealizedmajorbenefitsofsimulation,includingimprovedoperatortrainingandfamiliarization,andthefacilitynowhasarigoroustest-bedforprocesstesting.
INDUSTRY:POWER
SSE www.sse.com
© Jonathan Thacker - http://www.geograph.org.uk/photo/2006958
Scunthorpe, North Lincolnshire, United Kingdom —TheRiverTrenthasahistoryofchangingcourseovertheages,withmentionofitsmeanderingsevenintheworksofWilliamShakespeare.OnceamajorcommercialwaterwaymarkingthetraditionalboundarybetweenNorthernandSouthernEngland,theriverisrelativelystabletodayandisthesourceofrecreationanddrinkingwater,aswellascoolingwaterforalargenumberofcoal-andgas-firedelectricalpowerplantsalongitsroute.Oneofthoseplants,KeadbyPowerStationatScunthorpeinNorthLincolnshire,isoperatedbySSE,oneofthelargestenergycompaniesintheUnitedKingdom.TheKeadbyplant,whichbegancommercialoperationin1996,isa720-megawattcombined-cyclegasturbinegeneratingfacility.
TheKeadbypower-generatingplantincludestwoGeneralElectricframe9FAgasturbines,oneAlstomsteamturbine,twoBabcockthree-pressurewasteheatrecoveryboilersandaSiemensGT10Bauxiliarygasturbine.Itismaintainedandoperatedbyastaffof53includingmanagers,engineersandtechnicians.WhenSSEmanagementrealizedthefacility’sDistributedControlSystemwasapproachingplant-wideobsolescence,thecompanychoseInvensysOperationsManagementtoupgradetheplanttoamoreflexible,scalable,andsupportablesolution.
SSEisaverticallyintegratedenergyutility,andisinvolvedinthegeneration,transmission,distributionandsupplyofelectricityaswellasthestorage,distributionandsupplyofnaturalgas,telecommunications,contractingandenergyservices.SSEhasmorethan10millioncustomeraccountsintheUK,supplyingnaturalgasandelectricitytomorethan3.5millionhomesandbusinesses.ItownstheUK’slargestonshoregasstoragefacilityatHornseainEastYorkshireandiscurrentlybuildinganew,largerfacilityatAldbrough.Inaddition,thecompanyhasoneofthelargestelectricalcontractingbusinessesintheUK,operatingfrom60regionaloffices.AstheUK’slargeststreetlightingcontractor,SSEalsomaintainsover1millionlights.
Thecompanyhasatotalofmorethan11,300megawattsofcapacity,2,000megawattsofwhichisinstalledrenewablecapacity.Assuch,SSEistheUK’ssecondlargestgenerationbusinessoverall,andthelargestgeneratorofelectricityfromrenewablesources.SSE,formedwiththemergerofScottishHydroElectricandSouthernElectric,alsohasanownershipinterestinmorethan100thermalandrenewablepowerstations.
Shining the Light on a New Infrastructure Approach
Beforetheupgrade,themajorityoftheplantwasoperatedbyasite-wideEmersonWDPF(WestinghouseDistributedProcessFamily)DCSsystem.Amoderate-sizedcontrolsystem,thisincluded26fault-tolerantcontrollers;12HMIworkstations,includingonehistorianandcomprising6,046hardwiredI/O,eightcontrolleveldatalinks(Modbus,Allen-BradleyDH+,GE-GSM);threesupervisoryleveldatalinks(Modbus-TCP,ODBC,OSI-PI);and190processscreens,includingapproximately130overlaysand48sequences.
SSEengineersinitiallyidentified7keycriteriafortheDCSupgradeprojectatKeadbyPowerStation.Topoflistwasthattheupgradehadtobecompletedintimeforascheduledmajorplantoutageandthesystemmigratedwithminimalsitecommissioningtime.Inaddition,thenewDCSsystemhadtoaddressthepressingobsolescenceissuesandremaincurrentfortheremainderoftheplant’sexpectedservicelife.Sufficientexpandabilityintermsofcontrollermemory,I/Ocapacityandnetworkbandwidthtogetherwithsimplifiedonlineconfigurationwasalsoconsideredakeyrequirement.Becauseofthepotentialimpactonoperatingproceduresandotherhumanfactors,engineersalsospecifiedthatthenewplantsolutionshouldmaintaintheexistingcontrolstrategiesandHMIinterfacestandards.
Upgrading Systems in Harmony with Existing Operations and Upgrades
Asplanningprogressed,itbecameclearthattheDCSupgradehadtobeconductedinparallelwithessentialmajormaintenanceactivitiesaswellasotherexpansionprojects.Furthermore,siteworksneededtotakeplacewithminimaldisruptiontotheoutageprogramme.Ariskassessmentoftheprojectrequirementidentifiedtwokeyareasofconcern:theI/Oupgrade,andapplicationsoftwaremigration.FortheI/Oupgrade,plantengineersatKeadbycitedchallengessuchasfadedconductoridentificationlabels,incompleteloopdrawings,humanerrorrisksandthepotentialimpactontheoutageprogrammeassociatedwithon-siterewiringandtestingofapproximately6,000loops.
“Althoughtheexistingsystemhadbeenreliableinthepast,problemswereemerging,”saidHughFerguson,C&IengineeratKeadbyPowerStationandprojectmanagerfortheDCSupgradeproject.“Anincreasingnumberof
componentswereeithernolongeravailableornolongerrepairable.Plus,controllermemorywasnearcapacityandmostofthedatahighwaybandwidthwasalreadyutilized.”
Migrationoftheapplicationsoftwarewasalsoconsideredapotentialproblemarea.Documentationwaslimitedandtherewerenocontrolnarrativesavailable.Thismeantthattheapplicationsoftwareitselfhadtobeusedasthesourceforthemigrationprocessraisingconcernsoverthepotentialforhumanerror,theskill-setsrequired,andthefunctionalacceptancetestcriteria.
Basedonthepotentialobstacles,itwasnotclearwhethertherewasanalternativetoupgradingtoOvation,thenextgenerationoftheWDPFplatform.However,becauseofconcernsoversoftwareacceptancetestingandcontinuedsupportfortheexistingI/Ohardware,SSEdecidedtogoouttoTenderfortheproject.
SixDCSvendorspre-qualifiedfortheproposedmigrationproject,withfourvendorsaskedtopresentformaltechni-calevaluationsoftheirproposedsolutions.
InvensysOperationsManagementwasultimatelyselectedbySSEbecauseoftheirprovenplug-inI/OcardmigrationsolutionforWDPF,WDPFmigrationexpertise,in-housesimulationcapabilitiesandtheincorporationofamodel-basedplantsimulatorforapplicationsoftwaretestingandoperatortraining.
Invensys Mastery of the Migration Process
InvensysWDPFmigration-styleFBMsareaplug-inreplacementforWDPFQ-LineI/OcardswhichallowtheexistingWDPFI/Oracks,power-supplies,andfieldwiringtoberetainedandre-usedbythenewFoxboroIAsystem.FromanIAsystemperspective,thesemodulesappearidenticaltostandardFoxboro200-seriesFBMs.
Semi-automatedtoolswereofferedtomigratetheWestinghouseapplicationtotheInvensysInFusionenvironment.InFusionistheInvensysdeliverymechanismforenterprisecontrol,andconsistsofthehardwareandsoftwarecomponentsnecessarytoprovideatrueaggregatedviewofinformationacrossanorganization,enablingarobustfoundationforcollaborationbetweenpeople,processesandsystems.
TheSimSci-EsscorDynamicSimulationSuiteprovidesbothmodel-basedplantsimulationandaplatformforenablingacompleteOperatorTrainingSimulator(OTS)solution
comprisingvirtualizedDCScontrolprocessors,interfacestothird-partyvirtualcontrollersandafeature-richtrainingenvironment.TheSimSci-Esscorsolutionprovidesthefullpowerofrigorousdynamicsimulationandcontrolsystememulationforprocessengineers,plantengineers,opera-torsandmanagerstoimproveplantdesign,checkoutcontrols,trainoperatorsandimproveplantperformance.Italsooffersamodernalternativetodated,fragmented,empiricalandhard-to-useproductswithwhichmanyengi-neeringfirmsandplantscurrentlystruggle.
InvensysalsodemonstratedanextensivetrackrecordforsupportingtheFoxboroI/ASeriesDistributedControlSystem,akeycomponentoftheInvensysInFusionEnterpriseControlSystem,andwereabletoofferanumberofproductstofurtherenhancementthesystemincludingSequentialFunctionChartsforDCSsequencesandtheROMeoOnlinePerformanceSuiteforplantperformancemetrics.
ROMeoisanadvanced,unifiedmodelingenvironmentdeliveringonlineoptimizationapplicationstohelpusersobtainpeakperformancefromtheiroperatingunits.RO-Meooffersprocessoptimizationacrossanentireenterprisewithonlinemodelingandequation-basedoptimizationcapabilitiesprovidingmoreaccurate,currentoperatinginformationtobettermanagechangingmarketpressures,productvalues,energycostsandequipmentperformance.“ThemigrationapproachofferedbyInvensysOperationsManagementshowedthatanalternativetotheexistingsystemwasaviableoption,”saidHughFerguson.“Simulationisalsoprovingparticularlyusefulatresolvinghard-to-replicateproblems,andwasinvaluableinleveragingtheexperienceofplantoperatorsduringmigrationoftheapplicationsoftware.”
Initially,migrationoftheDCSapplicationsoftwareanddevelopmentoftheOTSplantmodelwereundertakenasseparate,parallelactivitiesbyseparateInvensysprojectteams.Oncecompleted,thesetwoelementswerethencombinedtoallowfunctionaltestingintheFactory,priortoinstallationatsite.
Oncethesystemarchitectureandhardwareandbeenspecified,theInvensysDCSteambeganbydevelopingmigrationtoolsandcarryingoutcodeanalyses;breakingtheapplicationdownintoHMIcomponents,interlock/protectionlogic,sequences,uniquestrategies,andtypicals.MigratedDCScomponentswerethentestedonamodularbasisviaacombinationofcodereviewsandbasicI/ASeriesfunctionaltesting.