Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above...

28
Product Overview

Transcript of Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above...

Page 1: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Product Overview

Page 2: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Geist designs and manufactures intelligent hardware and software for the four cornerstones of data center management:

Independently, each Geist product line offers industry leading capabilities and technology. Together, these products combine to create a comprehensive system for maintaining a secure and efficient data center. With scalable systems for everything from single cabinets to an entire enterprise, each customer benefits from solutions that are designed to fit their specific needs.

The Geist culture has revolved around the customer for more than 60 years, and it’s evident in the way we do business today.

Our Mission: Geist will be the best provider of products and services to our customers, setting the standard by which all others will be compared.

POWER

MONITOR

COOL

MANAGE

From Power Strips to DCiM Solutions

Page 3: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

This brochure contains an overview of the products offered by Geist. For more information go to www.geistglobal.com or call our sales team on 800.432.3219.

Industry Leader

• Established in 1948 • 65 years of continuous growth• Privately held company• 20% employee owned• Installations globally• Office locations in US, China and Europe

Quality

We are dedicated to developing the highest performing products and solutions in the industry. From hand-soldered connections in our power strips to enterprise level DCiM implementation teams, we consistently exceed our customers’ expectations.

Tailored

Geist has been customizing cost-effective solutions for clients for more than 60 years. It’s part of our culture. Every customer offers unique challenges and opportunities. Geist can take your road map and desired features and make them a reality. We are committed to quickly meet each specific customer need with technological savvy and unbeatable detail.

Page 4: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

POWER

Offering thousands of standard PDUsand extensive customization options

PowerDistribution

Page 5: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

5www.geistglobal.com

POWER

Power Solutions for All Applications

From robust basic units to sophisticated outlet level switching units, Geist supplies a huge range of standard units but also specializes in build-to-order PDUs that meet the unique needs of each application. Our on-site raw materials processing center allows for higher quality control and shorter lead times of custom units.

• Made in the USA• ISO 9001 certification• Orders ship within 3 days• Custom order ship in as little as 5 days• Record of 99.5% on-time delivery• On-site UL testing lab• All units 100% tested on-site

Locking Cord Sets

In addition to offering locking receptacles on intelligent units as standard, Geist also offers locking cord sets to give double protection from unplanned cable detachments, preventing downtime and potentially damaging outages.

Page 6: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

6 www.geistglobal.com

POWER

Switched Power

Geist switched PDUs provide hands-on power—even from miles away. While monitored PDUs can display information remotely, only switched PDUs offer the ability to use that information and stay in control of individual power outlets. Manage critical issues that arise with the click of a few buttons on a smart phone or computer. Disable problem equipment by cutting power to specific outlets and reboot equipment remotely by cycling power.

The Switched Ultra Series has outlet level power monitoring for granular power consumption data of all equipment. A Max Group Amps feature offers an extra level of protection by preventing circuit overload via user-set thresholds.

Current Monitoring

Geist current monitoring PDUs allow local or remote viewing and alarms for issues that can arise at the outlet, breaker, circuit and aggregate level. With the advantage of seeing current usage feedback in an instant, the chances of overloading a PDU when adding, removing or adjusting equipment is minimized. Current Monitoring PDUs are available with unit level or outlet level monitoring capabilities.

Page 7: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

7www.geistglobal.com

POWER

Locking Receptacles

Geist offers IEC C13 and C19 receptacless with an integrated locking feature built within the receptacle housing. The locking mechanism protects against vibration and external elements that can easily dislodge external locking clips or guides. This self-contained locking mechanism works with any standard IEC plug, without the use of lacing bars or extra accessories. Locking receptacless are standard on some units and available for custom orders.

Power Monitoring

Geist RCO PDUs provide a comprehensive view of outlet level power usage in a data center. Local and remote power monitoring display options offer quick access to each outlet’s current, volts, real power, apparent power, power factor and kiloWatt hours. The environmental sensor ports provide the ability to track critical climate variables. Power Monitoring PDUs are available with unit level or outlet level monitoring capabilities.

Page 8: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

POWER

Satellite Power

Geist’s line of satellite PDUs maximizes the remote reporting capacity of a single IP address. Without a satellite PDU or a data aggregator solution like Geist’s Racknet-A, data center managers wanting to broaden the reach of their remote monitoring capabilities would have to assign a single IP address to each intelligent PDU. Geist’s satellite PDUs solve this problem by connecting remote capable devices under the same IP address.

Geist’s range of satellite PDUs offer a variety of current, power and environmental monitoring options. Geist also offers Satellite Switched units for users that require more control.

Geist’s DCiM Solutions further enhance the control of intelligent PDUs and limit the use of IP addresses. Track, present and control intelligent PDUs and environmental data easily with Geist’s Racknet-Aggregator.

8 www.geistglobal.com

Page 9: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

POWER

The current meter option provides an accurate True RMS reading of the current draw to monitor PDU performance closely and ensure equipment power usage is within acceptable ranges—helping avoid nuisance breaker trips.

The power meter offers more detailed power information through a scrolling display of the four critical power measurements: power factor, amps, volts and watts.

Auto Transfer Switch

Geist’s auto transfer switch provides redundant power for single-lead data center equipment. If the primary power source experiences failure, the transfer switch automatically shifts to a secondary source, ensuring uninterrupted service. Once the power from the primary source is restored, the unit automatically switches back to the original source of power.

Basic Power

Reliable power distribution with no frills, just 100% performance, guaranteed for life. Geist basic PDUs come in surge, non-surge, IEC and NEMA configurations. Incorporating an optional current or power meter is especially useful when adding, removing or adjusting equipment, because they provide instant power usage feedback, helping you avoid overload and costly downtime.

9www.geistglobal.com

Page 10: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Maximize cooling efficiency while easily maintaining a perfectly controlled temperature.

COOL

Air Management System

Page 11: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

COOL

Geist’s AgileAir solutions offer sophisticated airflow management to data centers of any size and capacity. By containing and directing hot air, the AgileAir line delivers significant cost savings while improving the long-term reliability of mission critical IT equipment. Also, AgileAir accomplishes the following:

• Maximizes efficiency while easily maintaining an ideal temperature throughout the data center

• Contains and evacuates 100% of the heat— so there’s no heat mixing with the cool air

• Exhausts heat directly from the cabinets, eliminating cool air bypass

• Maximizes chiller plant efficiency with the highest possible return air temperatures

• Eliminates makeshift solutions—like vinyl plastic sheeting—with expertly manufactured chimneys and rack enclosures

• Maintains a perfectly controlled and consistent IT environment

Airflow Assessment Program

Geist’s highly-trained team of experts conducts a thorough site survey to identify key airflow trouble spots and recommend viable solutions in a customized Airflow Assessment Report. This assessment provides detailed insight to the efficiency of your airflow management, and summarizes the necessary steps to maximize cooling efficiency.

For more details on conducting an Airflow Assessment in your data center, simply call or email one of Geist’s cooling experts at 800.432.3219 or [email protected].

11www.geistglobal.com

Page 12: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

COOL

Active Cabinet or Row Containment

The AgileAir containment system centers on containing heat and expelling it directly to the CRAC units. The combination of hot air containment and intelligently controlled fan speed creates a consistent climate controlled environment in the data center and within the cabinet rows.

A. Custom Chimney AgileAir chimneys are adjustable to accommodate most ceiling heights.

B. Fan UnitsAgileAir fan cartridges evacuate hot air to maintain a constant temperature in the cabinet.

C. Intelligent ControllerThe brains behind AgileAir, the intelligent controller automatically adjusts fan unit speeds to exhaust exactly the right amount of air from the cabinet to maintain the desired temperature. The intelligent controller also logs and records valuable temperature and performance data.

D. Pressure Sensors Sensors measure internal (Item D1) and external (Item D2) cabinet pressure and transmit this data in real-time to the intelligent controller (Item C). The intelligent controller is programmed to maintain evenly balanced cabinet pressure by manipulating the speed of the fans (Item B). The process of balancing the pressure inside the cabinet with external pressure precisely regulates temperature. Using pressure to regulate temperature serves as the primary differentiator between AgileAir and other cooling solutions.

12 www.geistglobal.com

Page 13: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

COOL

A

B

CD1

D2

13www.geistglobal.com

Page 14: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Passive Containment

With AgileAir Passive Cabinet Containment, low density cabinets can take advantage of a simple chimney solution to manage modest heat volumes. Then, as cabinet loads begin to increase, the passive system can be upgraded quickly to an AgileAir Active Containment System. AgileAir is the most flexible cooling option on the market today. It grows and adjusts to the needs of any data center, with features such as:

• Efficient chimney system - For low density cabinets (up to 4kW) - Heat is channelled directly to the hot air return - No mixing with the cooler ambient air

• No active components - Relies on server fans to push exhaust

• Seals cabinets for maximum efficiency - Blanking panels minimize hot air mixing

• Highly economical • Occupies zero floor space

- Mounted above the rack, not on the door• Easily upgradable to an active system for higher density cabinets

Removable blanking panels capture heat. As cabinets increase in density they can be upgraded to an AgileAir Active Containment System.

14 www.geistglobal.com

COOL

Page 15: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

COOL

Maintain maximum cooling efficiency with airflow management accessories by Upsite Technologies®. Located in the Cooling In-Rack Options section at www.geistglobal.com.

15www.geistglobal.com

Page 16: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Device Cooling

Network switches, load balancers, routers and many other devices are often mounted in the back of the cabinet for more convenient cabling connections. Unfortunately, in that location, these devices can be critically damaged or may go offline when they are fed air that has been pre-heated by the servers. AgileAir Device Cooling addresses this issue by delivering cool air to network devices regardless of where they are mounted in the rack. The Geist device cooling products are available in a wide range of configurations and rack space sizes. Designed to work with 1U to 9U devices and beyond, AgileAir Device Cooling channels air to every kind of intake/exhaust configuration imaginable.

AgileAir Device Cooling products are configured to accommodate numerous intake/exhaust configurations. 

16 www.geistglobal.com

COOL

Page 17: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

COOL

Network switches (Item A and AA) mounted at the top and rear of the rack are susceptible to heated air from the servers. This hot air is recirculated, putting stress on the device.

AAA

Blanking Panels

AgileAir Device Cooling (Item B) directs cool air to the network switches, lowering operating temperatures significantly.

B

17www.geistglobal.com

Page 18: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

From temperature to humidity to airflow, Geist climate sensors monitor critical environmental conditions.

MONITOR

EnvironmentalMonitoring

Page 19: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

MONITOR

Environmental factors pose a severe threat to your mission critical infrastructure. These dangers are minimized with a network of Geist sensors collecting and funneling information to a single point.

Geist’s monitoring line of products allows users to observe conditions from a secure Web interface and receive SNMP, email, text message or voice call alert notifications when environmental sensors detect a problem.

The Web interface can display live video surveillance and environmental measurements, including temperature, humidity, airflow, light, sound, power, water detection and more. Measurements are logged and graphed to track trends. Sensors can be controlled by programmed values or manually through the Web interface.

19www.geistglobal.com

Page 20: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

MONITOR

RS-Wi Wireless Monitoring

The RS-Wi Wireless Gateway is designed for easy integration with data center monitoring and Geist’s DCiM systems. The convenient wireless design helps reduce installation costs associated with hard-wired sensors. An auto-discover mechanism detects sensors as they are installed within the monitoring network.

RS-Wi Compatible Sensors

• Digital temperature sensor• Digital temperature/humidity sensor• Digital temperature measurement & dry contact• Digital motion sensor• Analog input transmitter• Analog input sensor• Point repeater

www.geistglobal.com20

Integrated Sensors

A complete range of analog and digital sensors is available to connect to Geist power strips and environmental monitors. Many Geist devices also have embedded environmental capabilities. The data collected from the sensors can be stored using Geist software packages, and/or viewed through an online web interface.

Digital Sensors

• CCAT analog to digital converter• IOE Expander• Temperature, airflow, humidity, dew point sensors

Page 21: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

MONITOR

Analog Sensors

• Smoke and carbon monoxide detectors• D-Link® wireless cameras• City power monitor• Direct current volts sensors• Current transformer• Door position sensor• Leak detection cable and water sensor

Accessories

• -48 volt DC power supply • 5-port and 16-port splitters• Auto dialer• Power over Ethernet splitter and injector

www.geistglobal.com 21

THD Sensors

Geist’s new digital sensors – the THD & T3HD - can simply be daisy-chained to provide more sensors from a smaller number of environmental units. The T3HD provides optimised top-middle-bottom rack temperature sensing in a single sensor arrangement; ideal for data centre managers who are looking to follow ASHRAE monitoring guidance.

Page 22: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

A single point of access for managing mission critical hardware.

MANAGE

DCiM Solutions

Page 23: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

MANAGE

Easy. Intuitive. Effective.Simply Intelligent DCiM

Environet provides all of the data granularity required for efficient management of the data center. It offers unprecedented visibility and management over environmentals, power consumption, cooling and more—transforming complexity into simplicity. Environet’s interactive interface provides critical information to drive knowledge-based decision making. Access to real-time, holistic information about assets, power, environment, connectivity and process empowers you to proactively manage moves, adds and changes. With Environet, decisions are made with speed and confidence—not guesswork.

Colocation Management

Environet DCiM solution from Geist offers an unmatched user experience. Our comprehensive tool set is designed to make managing your colocation facility easier than ever before. With features like Tenant Billing Manager that calculates real-time kWh usage at the server level using peak and non-peak rates, Environet provides unique tools that are easy to implement and deliver effective outcomes.

23www.geistglobal.com

Page 24: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Racknet Product Family

Manage IT and white space with a single point of integration. The Racknet product family offers vendor-neutral options that allow you to integrate and manage a variety of mission-critical equipment. User-defined graphics, calculations, and reports allow for a holistic view of your entire data center.

Racknet-Aggregator (Racknet-A): Racknet-A connects to GNET via 48 aggregation ports to collect critical data from Geist products. Racknet-A provides visibility to data from Geist power strips in one, centralized location. It prevents users from having to set up thousands of IP addresses on the production network and saves space on costly network switches. Racknet-A communicates via SNMP and supports up to one thousand devices.

Racknet-Aggregator Server (Racknet-AS): Racknet-AS includes the full feature set of the Racknet product line. It can be used with third-party equipment, has 48 aggregation ports for direct connection, and includes full customization capabilities.

Racknet-Server (Racknet-S): Racknet-S gathers data from Geist products as well as third-party equipment. It also allows users to fully customize graphics and collections. In addition, Racknet-S comes with the ability to derive values from monitored points to create meaningful views of data.

MANAGE

Racknet-A

24 www.geistglobal.com

Page 25: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

MANAGE

25www.geistglobal.com

Page 26: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Environet

Environet is a custom-built, fully scalable system with a single point of access for all your monitoring needs. It is an enterprise level system that focuses on integrating many types of equipment via various communication protocols for complete visibility. With Environet, you do not have to worry about design, installation, configuration, or system maintenance. Geist designs, programs, installs, and provides support for all Environet systems—they are 100% turnkey.

• Enterprise scalable• Complete toolsets• Custom-built feature sets• Virtually unlimited capacity• Set up and maintained for you

Racknet Product Family

Racknet is designed primarily to give visualization to rack level data and white space, although it is capable of integrating with other monitoring systems. Racknet can be set up and configured by users or by a professional installer, but is capable of being 100% user maintained. Racknet uses an SNMP auto discovery tool to make configuration fast and easy, while template devices make adding equipment to the system simple. Racknet is shipped pre-installed on a server for quick set up.

• White space and rack level monitoring• Extensive feature set• Capable of custom graphics and tools• Up to 20,000 points• User maintainable

MANAGE

26 www.geistglobal.com

Page 27: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

MANAGE

Environet Racknet

Capacity

Number of Points Scalability

UnlimitedEnterprise

Up to 20,000Multi-device

Communication

SNMP BACnet Modbus LONworks Hardwired I/O oBIX API

XXXXXX

X with converterwith converterwith converterwith converter

X

Design & Configuration

System Configuration Vendor Neutral Consulting Services Professional Installation Support Contract Custom Built Features

turnkeyXXXXX

user-capable X

additionaladditionaladditional

N/A

Features

Chart Builder Notification & Alarms Report Manager Energy Cost Analysis Power One Line PUE/DCiE Unique Floor Plans & Views Key Performance Indicators Power Capacity Planning

XXXXXXXXX

XX X

capablecapablecapablecapablecapablecapable

Integration

Raised Floor/White Space Electrical/Mechanical Rooms Fire Suppression Systems Building Management Systems Network Management Systems Security Systems Other Custom Systems

XXXXXXX

X capablecapablecapablecapablecapablecapable

27www.geistglobal.com

Page 28: Power PDUs | Data Center Solutions, Services and …...• Occupies zero floor space - Mounted above the rack, not on the door • Easily upgradable to an active system for higher

Geist Americas 1821 Yolande Ave.Lincoln, NE, 68521 USA1.800.432.3219 Tel: 402.474.3400 www.geistglobal.com

Geist DCiM 2290 East Prospect Rd, Ste. 6Fort Collins, CO 80525 USATel: 1.877.449.4150

Geist Europe Unit 1, The Monarch Center, Venture Way, Priorswood, Taunton, Somerset, TA2 8DE UKTel: +44 (0)1823.275100

Geist Asia China Tiley Plaza Bldg A, Unit #2808, No.199 Haide 3 RoadNanshan, Shenzhen, Guangdong Province, ChinaPostal Code 518000Tel: +86.755.86639505

Geist Asia Hong Kong [email protected]: +852.90361927