Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National...

31
Power Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory USDOE Vehicle Technologies Office Annual Merit Review and Peer Evaluation, Washington, D. C., June 6, 2017 EDT078 This presentation does not contain any proprietary, confidential, or otherwise restricted information. NREL/PR-5400-68077

Transcript of Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National...

Page 1: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

Power Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory USDOE Vehicle Technologies Office Annual

Merit Review and Peer Evaluation, Washington, D. C., June 6, 2017

EDT078

This presentation does not contain any proprietary, confidential, or otherwise restricted information.

NREL/PR-5400-68077

Page 2: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

2

Overview

• Project start date: 2017 • Project end date: 2019 • Percent complete: 30%

• Size and Weight • Performance and Lifetime • Cost

Timeline Barriers

• John Deere • Kyocera • Oak Ridge National Laboratory

(ORNL) • Project Lead – National Renewable

Energy Laboratory (NREL)

Partners Budget • Total project funding

o DOE share: $493K

• Funding for FY 2017: $493K

Page 3: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

3

Why is thermal management essential? Manage and dissipate heat Limit failure, increase reliability Increase power density

Transition to wide-bandgap (WBG) devices changes, but does not reduce, need for thermal management

WBG devices • More efficient Less heat • Yield and cost issues Smaller die sizes/Reduced area • Reduced area Increased heat flux • Higher junction temperature Larger temperature gradients, impacts

other components that may not tolerate higher temperatures: o At the module level: bonded interface materials, thermal greases o At the inverter level: DC-link capacitors, electrical boards

Relevance

Page 4: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

4

Objective: Develop thermal management techniques to enable high-temperature WBG devices in automotive power electronics

• Estimate component temperatures (e.g., capacitor, electrical board, solders) under elevated device temperature conditions

• Evaluate the effect of different under-hood (all-electric, hybrid electric) temperature environments on component temperatures

• Evaluate thermal management strategies for novel, compact inverter designs

Relevance

Page 5: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

5

Power Electronics Thermal Management

WBG Power Electronics Thermal Management

Approach/Strategy

Advanced Cooling Technologies for John Deere Inverter (cooperative research

and development agreement [CRADA])

Photo Credit: Gilbert Moreno (NREL)

Page 6: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

6

Approach/Strategy

Create thermal models of an automotive inverter

Simulate WBG operation using the inverter model

Develop thermal management strategies

for WBG-based inverters

Validate the thermal models

Experimentally validate some key thermal management concepts

WBG Power Electronics Thermal Management

Photo Credit: Scot Waye (NREL)

Capacitors

Modules

Simulate elevated junction temperature conditions (up to

250°C)

Evaluate effect of different under-hood temperature environments

(hybrid and all-electric)

Identify the components (e.g., capacitor) that are not expected to

survive WBG conditions

Advanced compact inverter designs

Cooling strategies • Capacitor cooling • Bus bar cooling • Aggressive thermal

management solutions

Page 7: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

7

Capacitors: Metalized film

Power modules and gate driver board

z r

φ

Capacitor winding thermal conductivity (k)

kz = kφ = 0.46 W/m-K kr = 0.16 W/m-K

Electrical board thermal conductivity (k)

kx = ky = 0.81 W/m-K kz = 0.29 W/m-K

z

x y Electrical pins included to account for the thermal

path from the devices to the gate driver board

Inverter Model Description

2012 Nissan LEAF inverter

Model-predicted junction-to-coolant

resistance within ±6% of

experimental data

Model-predicted capacitor

temperature within ±1°C of

experimental data

Page 8: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

8

copper-molybdenum

cold plate

Device

solder

solder copper baseplate

TIM-dielectric-TIM

cold plate

solder

solder copper baseplate

TIM

DBC

Device

LEAF LEAF (DBC)

Inverter Model Description

Created two models – Attempt to account for the effect of different inverter designs on component temperatures

• Uses flexible film as the dielectric • Uses two thermal interface material

(TIM) layers

• Uses direct-bond copper (DBC) substrate as the dielectric

• Has 28% lower thermal resistance compared with flexible-film design

• Typical of most inverter designs

Page 9: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

9

Milestones / Approach

Date Description of Milestone or Go/No-Go Decision

December 2016 (complete)

Go/No-Go: Model the thermal performance of various inverter designs and evaluate the effect of the thermal management concepts developed on each type of inverter.

March 2017 (complete)

Milestone: Model the effects of degrading material thermal properties (e.g., increasing heat generation rates and thermal resistance)

June 2017 (in-progress)

Milestone: Model heating-related effects associated with integrating the inverter close to the electric motor.

September 2017 (in-progress)

Milestone: Summarize the cooling concepts developed and down select one or two concepts for experimental validation.

Page 10: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

10

* Results reported last year

• Increasing under-hood temperature does not have a significant effect on capacitor temperatures • For all cases, capacitors exceed 85°C (typical limit of polypropylene film capacitors) • Lower junction-to-coolant resistance of DBC-based design provides lower capacitor

temperatures • Power module’s heat is the primary reason for excessive capacitor temperatures

Accomplishments: Computed Capacitor Temperatures

112

120

135

110

116

128

80

90

100

110

120

130

140

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

140°C Under-hood Temperature(hybrid-electric vehicle, near engine)

LEAF *

LEAF (DBC)

108

116

131

105

110

123

80

90

100

110

120

130

140

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

75°C Under-hood Temperature (all-electric vehicle)

LEAF *

LEAF (DBC)

Page 11: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

11

100

125

150

175

200

225

250

275

0% 10% 20% 30%

Tem

pera

ture

(°C

)

TIM Thermal Resistance Degradation (%)

75°C Under-hood Temperature

Accomplishments: TIM Degradation Effects

Junction temperature increase ~ 8°C

Gate driver temperature increase ~ 5°C

Capacitor temperature increase ~ 3°C

Initial TIM thermal resistance = 55 mm2-K/W

Junction

Gate driver

Capacitor

DBC Design

cold plate

copper baseplate TIM

DBC

Page 12: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

12

Cold plate

1. Improved power module cooling

2. Cooling the capacitors using cold plates (one or two sides)

3. Cooling the DC bus bars using cold plates (one or two sides)

Power modules

Capacitors

Accomplishments: Capacitor Cooling Strategies

• Used a coolant temperature of 65°C • These three capacitor-cooling strategies were evaluated on four inverter configurations

Page 13: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

13

I. Flexible dielectric (LEAF) configuration II. DBC module [LEAF (DBC)] configuration

Finite Element Analysis (FEA) model

Two module configurations evaluated

Accomplishments: Inverter Configurations Evaluated

copper-molybdenum

cold plate

Device solder

solder copper baseplate

TIM-dielectric-TIM

cold plate

solder

solder copper baseplate

TIM

DBC

Device

Page 14: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

14

Two module configurations evaluated: III. Cold plate (CP) cooled with TIM layer between module and cold plate IV. Baseplate (BP) cooled, no TIM layer

MOSFETs (3.1 × 3.4 mm) Diodes (2.3 × 2.3 mm)

Cree Silicon Carbide Module (DBC substrate, aluminum-nitride ceramic)

Accomplishments: Inverter Configurations Evaluated

Photo Credit: Gilbert Moreno (NREL)

FEA model

MOSFET: metal–oxide–semiconductor field-effect transistor

Page 15: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

15

Cold plate

1. Improved power module cooling • Conventional cold plate (lowest performance) • High-performance, commercially available cold plate • Jet impingement-microchannel cold plate (highest performance)

Power modules

Capacitors

Accomplishments: Capacitor Cooling Strategies

Page 16: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

16

50

75

100

125

150

175

0 20 40 60 80 100 120 140

Max

imum

Cap

acito

r Tem

pera

ture

(°C

)

Convective Thermal Resistance (mm2-K/W)

Tj = 250°C

Accomplishments: Improved Module Cooling

Tjunction = 191°C

Tjunction = 214°C

Tjunction = 200°C

Tjunction = 217°C

Photo Credit: Gilbert Moreno (NREL)

Increasing thermal performance

Reduced capacitor temperatures by as much as ~40°C using a very-high performance cold plate

Conventional cold plate

Jet impingement-microchannel cold plate

High-performance, commercially available cold plate

Page 17: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

17

Accomplishments: Improved Module Cooling

Reducing the junction-to-coolant thermal resistance • Enables higher heat dissipation • Reduces heat spreading on module, which lowers capacitor and gate driver

temperatures • Enables compact packaging (increases power density)

Cree CP cooled Cree BP cooled

R”th j-c = 17 mm2/K/W R”th j-c = 15 mm2/K/W (11% lower than CP-cooled case)

Page 18: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

18

2. Cooling the capacitors using cold plates (one or two sides)

• Used a 3-mm-thick aluminum cold plate • Included effect of TIM layer (contact

resistance = 55 mm2-K/W)

3. Cooling the DC bus bars using cold plates (one or two sides)

• Used a 3-mm-thick aluminum cold plate • Included effect of dielectric pad layer

(contact resistance = 180 mm2-K/W)

Power modules

Capacitors

Accomplishments: Capacitor Cooling Strategies

Cold plate

Page 19: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

19

Accomplishments: Comparing Capacitor Cooling Strategies

Cooling the bus bars is more effective at reducing capacitor temperatures

60

70

80

90

100

110

120

150 175 200 225 250 275

Max

imum

Cap

acito

r Tem

pera

ture

(°C

)

Junction Temperature (°C)

Single-side cooling, high-performance cold plate (heat transfer coefficient 45,000 W/m2-K)

cold plate on capacitor

cold plate on bus bar

LEAF: orange LEAF (DBC): blue Cree CP cooled: red

Poor capacitor thermal conductivity limits effect of using cold plates on capacitors

Page 20: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

20

Accomplishments: Capacitor Cooling Strategies-Bus Bar Cooling

50

60

70

80

90

100

110

120

130

140

150

10 100 1,000 10,000 100,000

Max

imum

Cap

acito

r Tem

pera

ture

(°C

)

Convective Thermal Resistance (mm2-K/W)

Tj = 250°C, LEAF (DBC)

Air cooling Liquid cooling

Increasing thermal performance

30 x 75 mm

15 x 75 mm

5 x 75 mm

Bus bar cooled-surface area (one side)

Achieve capacitor temperatures < 85°C at 250°C junction temperatures using

• Small bus bar cooled area

• Relatively high convective thermal resistance (inexpensive cold plate)

Similar trends observed for other inverter configurations

Page 21: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

21

Response to Previous Year Reviewers’ Comments

This project is new for FY2017 as a partner with the power electronics activities at ORNL, but reviewer comments are provided below for the prior work.

• The reviewer commented that the 140°C capacitor temperatures were consistent with what others have observed and questioned if there is a proposed solution.

o Model results indicated that a bus bar cooling strategy using cold plates enables capacitor

temperatures below 85°C at junction temperatures up to 250°C.

• Reviewers commented that the applications of the thermal management techniques need to be better defined.

o The capacitor cooling strategies evaluated were conducted in such as way as to be applicable across a wide range of designs. For example, bus bar cooling can be designed into an inverter system using a custom-designed cold plate.

Bus bar surfaces potentially available for cooling (2015 BMW i3) Photo Credit: Xuhui Feng (NREL)

Page 22: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

22

Collaboration and Coordination with Other Institutions

• John Deere (industry): CRADA project to develop a power-dense, two-phase-cooled inverter

• Kyocera (industry): Evaluated substrate cooling configurations

• ORNL (national laboratory): Interactions related to ORNL’s benchmarking work

• Interactions with other industry contacts

Page 23: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

23

Remaining Challenges and Barriers

• Every inverter is unique, which makes it difficult to develop cooling strategies that are applicable to all inverters. We are working to develop thermal management concepts that are applicable to a wide range of inverter designs.

Page 24: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

24

Proposed Future Research

Capacitors

Electrical board Power module • Develop small and modular cold

plate designs for increased power density

• Develop device cooling strategies using dielectric fluids to reduce junction-to-coolant thermal resistance and reduce heat spreading

Collaborate with ORNL to develop thermal management strategies for novel, compact inverter concepts

Capacitors

Electrical board

Any proposed future work is subject to change based on funding levels

Page 25: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

25

Summary

Relevance • Supports transition to high-efficiency WBG devices in automotive power electronics. • Enables increased power density and use of lower cost components.

Approach/Strategy • Collaborate with ORNL to validate inverter-scale thermal models. • Use validated models to simulate WBG conditions and to develop thermal management strategies to enable

WBG-based power electronics systems. • Collaborate with John Deere to develop and implement a power-dense two-phase cooled inverter.

Technical Accomplishments • Created inverter-scale thermal models and computed inverter component (e.g., capacitor, gate driver board)

temperatures under high-temperature WBG conditions. • Conducted over 2,000 simulations to evaluate various capacitor cooling strategies. • Identified bus bar cooling as the most effective capacitor cooling strategy. This cooling approach enables

capacitors to operate at temperatures below 85°C at junction temperatures up to 250°C. • Collaborating with John Deere to develop a two-phase cooling strategy for their inverter. Collaborations • John Deere • Oak Ridge National Laboratory • Kyocera

Page 26: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

For more information, contact

Principal Investigator Gilbert Moreno [email protected] Phone: (303)-275-4447

EDT Task Leader

Sreekant Narumanchi [email protected] Phone: (303)-275-4062

Acknowledgments

Susan Rogers, U.S. Department of Energy

Team Members

Kevin Bennion (NREL) Xuhui Feng (NREL)

Page 27: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

Technical Back-Up Slides

Page 28: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

28

• Changing under-hood temperature has no effect on this component

• For almost all cases, gate driver board exceeds 125°C (typical temperature limit for electrical boards)

• Lower junction-to-coolant resistance of DBC-based design provides lower gate driver temperatures

Computed Gate Driver Board Temperatures

133

148

178

121

133

158

100

120

140

160

180

200

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

LEAF

LEAF (DBC)

75°C Under-hood Temperature *

* Results reported last year

Page 29: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

29

Computed Solder and TIM Temperatures

173

198

248

162

184

228

158

179

221

100

120

140

160

180

200

220

240

260

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

Device solder Substrate solder TIM

LEAF *: 125°C under-hood temperature

174

199

249

147

165

202

141

158

193

100

120

140

160

180

200

220

240

260

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

Device solder Substrate solder TIM

LEAF (DBC): 125°C under-hood temperature

* Results reported last year, but shown here for comparison

Page 30: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

30

Computed Molding Plastic Temperatures

LEAF *: 125°C under-hood temperature

LEAF (DBC): 125°C under-hood temperature

* Results reported last year, but shown here for comparison

149

167

206

118

125

142

100

120

140

160

180

200

220

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

Power module plastic Bus bar plastic

138

154

187

112

118

132

100

120

140

160

180

200

175 200 250

Max

imum

Tem

pera

ture

(°C

)

T junction, maxium (°C)

Power module plastic Bus bar plastic

Page 31: Power Electronics Thermal Management Electronics Thermal Management Gilbert Moreno National Renewable Energy Laboratory . USDOE Vehicle Technologies Office …

31

60

70

80

90

100

110

120

150 175 200 225 250 275

Max

imum

Cap

acito

r Tem

pera

ture

(°C

)

Junction Temperature (°C)

Double-side cooling, high-performance cold plate (heat transfer coefficient 45,000 W/m2-K)

Comparing Capacitor Cooling Strategies

Use of two cold plates reduces temperatures –provides temperatures below 85°C for most cases

cold plates on capacitor

cold plates on bus bar

LEAF: orange LEAF (DBC): blue Cree CP cooled: red

three results overlap