Power & Data Options€¦ · Options Discovery Vertex Duomo Forte Saber Modular Breakaway SightLine...
Transcript of Power & Data Options€¦ · Options Discovery Vertex Duomo Forte Saber Modular Breakaway SightLine...
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
251W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Power & Data Options
252 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Power & Data Options
Power Center
Overview
Power and Voice/Data Capabilities
Trough Dimensions
Power Planning
Voice/Data Planning
Perimeter Power
Overview
Power and Voice/Data Capabilities
Bracket Dimensions
Power Planning
Voice/Data Planning
254-257
258-259
Duomo® Shown
Power Center
Vertex Shown
Perimeter Power
Power Cove
Overview
Power and Voice/Data Capabilities
Voice/Data Planning
260-261
Forte® Shown
Power Cove
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
253W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Grommets
Round Grommet
Round Grommet Application
Power/Communication Option Availability At-A-Glance
Consult the individual product planning sections for specific application details.
Duomo Duomo Duomo Open SaberOptions Discovery Vertex Duomo Forte Saber Modular Breakaway Sight Line Satellite Training Mural
Power Center • • • •Perimeter Power • • • •Power Cove • • • • • •PowerPUP • • • • • • • • • •Mini-Port •Round Grommet • • • • • • •
264
Duomo® Shown
Grommets
Forte® Shown
PowerPUPPowerPUP
Overview
Power and Voice/Data Capabilities
Voice/Data Planning
262
Mural® Shown
Mini-Port
Mini-Port
Mini-Port Application
263
254 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Power Center
The Power Center is a concealed trough located inthe center of a conference table, between table bases.It provides power and voice/data connectivityfor individuals seated at a conference table.
The Power Center’s trough is equipped with power andvoice/data components. Access doors can be specified inmetal or wood. Multiple Power Centers can be useddepending on table size.
Each trough — whether 30" or 40" long — contains:• Eight (8) simplex receptacles• Four (4) single-gang faceplates (voice/data)• One (1) double-gang faceplate (voice/data)• 6' Hardwire power infeed standard. 6' Plug-inpower infeed option available.
The trough’s 6' power infeed can be routed through anybase location. Refer to pages 256-257 for detailed powerand voice/data planning information.
The gripper grommet provides access into the troughfrom underneath the table.
Not a drop-in unit.
One power infeed per Power Center.
Power and Voice/Data Capabilities
The Power Center is available on all Nucraftconference table collections 96" and longer.Refer to the individual product sections forspecific Power Center application guidelines.
Not available with round tops.
Simplex Voice Data Single- Double-Table Trough Qty. Of Receptacles Jacks Jacks Gang GangLength Length Troughs Provided Provided Provided Cutouts Cutouts
96" 30" 1 8 2 2 4 1120" 40" 1 8 2 2 4 1144" 30" 2 16 4 4 8 2168" 40" 2 16 4 4 8 2192" 40" 2 16 4 4 8 2216" 40" 2 16 4 4 8 2240"-2 40" 2 16 4 4 8 2240"-3 30" 3 24 6 6 12 3
Duomo® Shown
Double-GangFaceplate (Blank)
Access Doors
Simplex Receptacles
Wire Management Channels
GripperGrommet Insert with Jacks
Single-GangFaceplates
Power Island
Power Center
Power Infeed
Power Center ConfigurationTwo-Piece Top with Three Bases
Blank Insert
Vertex Shown
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
255W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Trough Dimensions Side and Plan View – 30"
End Elevation View – 30" and 40"
Side and Plan View – 40"
6"
6"
30"
6-3/8"
2-5/8"2-5/8"
40"
6-3/8"
7-5/8"7-5/8"
8-1/4"
6-3/16"
4"
9-1/4"
6"
256 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Power Planning Power Center Electrical System
• Eight (8) simplex receptacles provided per trough, located in the centerpower island.
• 4-wire, 2-circuit electrical system• Trough is pre-wired.• 15-amp hardwire power infeed standard. A licensed electrician is required to complete
hardwire connections to building’s power source. Plug-in power infeed option available.• 4-wire, 2-circuit electrical system supplied for standard hardwire infeed. Single circuit
electrical system supplied for optional plug-in power infeed.• All wires are 12 gauge.• UL listed.• One (1) double-gang cutout and two (2) single-gang cutouts are supplied for
future upgrades.
Electrical Diagram — For Hardwire Power Infeed
Note: For two circuits, Hot 1 + 2 should be connected to opposite sides of 240v bus.
Chicago Electrical Requirements
The city of Chicago may require hardwiring of electrical components. For Chicagoapplications, Nucraft provides a non-powered trough and power island. Electricalcomponents such as junction boxes and receptacles must be purchased in the field.Chicago-designated troughs will contain all standard voice/data components.
Other Municipality Electrical Requirements
Other metropolitan areas besides Chicago may have special electrical requirementsas well. Consult a local electrical contractor for proper code compliance information.
Black
Red
White
Green
Circuit 1-Hot
Circuit 2-Hot
Neutral
Ground
Power Center
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
257W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Voice/Data Planning The Power Center features faceplates with Decora-style bezel inserts.Equipped standard with:
• Two (2) NEMA size single-gang cutouts, each containing:One (1) Decora single-gang wallplate coverOne (1) Decora multimedia insert (2-port)One (1) RJ11 (voice) snap-in connectorOne (1) RJ45 (data) snap-in connector (category 5e)
• Two (2) NEMA size single-gang cutouts, each containing:One (1) Decora wallplate coverOne (1) Decora multimedia insert (blank)
Each single-gang cutout can be converted to a maximum of six (6) voice/data jacksor a duplex receptacle for additional power capability.
• One (1) NEMA size double-gang cutout with blank cover.
The double-gang cutout can be converted to a maximum of twelve (12) voice/datajacks or two (2) duplex receptacles for power capability. Prefabricated voice/data unitscan also be used (example: Extron).
Cutout Opening Dimensions
Nucraft recommends consulting an audio/visual (AV) integrator for assistance withvoice/data planning.
Voice/Data Product Manufacturers
Manufacturer Phone Number Web SiteAMP 1-800-522-6752 www.tycoelectronics.comAvaya 1-866-462-8292 www.avaya.comLeviton 1-800-722-2082 www.leviton.comPanduit 1-800-777-3300 www.panduit.comSiemon 1-860-945-4200 www.siemon.com
2-7/8"
2-3/8"7/16"
2-3/8"
3-5/16"
4-3/16"
8(2) Single-Gang Double-Gang
258 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Perimeter Power
Perimeter Power provides enhanced power and commu-nication connectivity for each individual seated at aconference table. Attached to the table’s apron, PerimeterPower maintains a clean aesthetic on the table top.
Perimeter Power is equipped with the followingcomponents:
• Hardwire power infeed (6')• Duplex receptacles• NEMA size single-gang cutouts (voice/data)• Single-gang wallplate cover (blank)• 20 AMP System
The hardwire power infeed has a modular connector onone end; the connector attaches to the back side of anypower block mounted on the table’s apron. This featureallows total flexibility in determining floor monumentlocation under any table base. All tables ship prewired.
Note: Clearance from the floor to the bottom of the apronis 24-3/4". Apron is recessed 2-1/8" under the table.
Perimeter Power Bracket Dimensions Front Elevation View End Elevation View
Power and Voice/Data Capabilities
Perimeter Power is available on all Nucraft conferencetables 96" and longer with the exception of Discoveryand AVID. Refer to the individual product sections forspecific Perimeter Power application guidelines.
Not available with round tops.
Total Single-Table Power Brackets Brackets Simplex GangLength Brackets Per Side Per End Receptacles Circuits Cutouts
96" 6 2 1 12 1 6120" 6 2 1 12 1 6144" 8 3 1 16 2 8168" 8 3 1 16 2 8192" 8 3 1 16 2 8216" 10 4 1 20 2 10240" 10 4 1 20 2 10
Note: Voice/Data Jacks are customer supplied
2-7/8"1"
2-3/8"1-3/16"
11"
5/16"
2-5/16"
3-1/4"
2-3/4"3"
Perimeter Power Configuration withTwo Piece Top with Three Bases (Plan View)
Forté® Shown
Vertex® Shown
Perimeter Power
Power Infeed
Power Bracket HardwirePower Infeed
Single-GangWallplate (Blank)
Power Block
Power JumperDuplex Receptacle
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
259W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Voice/Data Planning The Perimeter Power assembly does not include any factory-installed voice/datacomponents. It does include one (1) NEMA size cutout per bracket with a blankwallplate cover.
Faceplates and data connectors must be purchasedand installed in the field.
Voice/Data Product Manufacturers
Manufacturer Phone Number Web SiteAMP 1-800-522-6752 www.tycoelectronics.comAvaya 1-866-462-8292 www.avaya.comLeviton 1-800-722-2082 www.leviton.comPanduit 1-800-777-3300 www.panduit.comSiemon 1-860-945-4200 www.siemon.com
Nucraft recommends consultingan audio/visual (AV) integratorfor assistance with voice/dataplanning.
Power Planning Perimeter Power Electrical System
• 8-wire, 4-circuit modular electrical system.• All tables are pre-wired.• Hardwire power infeed only. A licensed electrician is required to complete hardwire
connections to building’s power source.• Neutral (white) wires are 10 gauge, hot and ground wires are 12 gauge.• All electrical components satisfy National Electrical Code (NEC) requirements
and are UL listed.
Electrical Diagram — Hardwire Power Infeed Only
Four circuits, one isolated. This electrical schematic can be used with three-phaseor single-phase power.
Chicago Electrical Requirements
The city of Chicago may require hardwiring of electricalcomponents. For Chicago applications, Nucraft providesa Chicago Power Junction Box instead of the standardmodular electrical system. Specific electrical componentssuch as receptacles must be furnished separately.
Other Municipality Electrical Requirements
Other metropolitan areas besides Chicago may have special electrical requirementsas well. Consult a local electrical contractor for proper code compliance information.
Cutout Opening Dimensions
2"
2"
3"4-3/4"
2-7/8"
2-3/8"1-3/16"
260 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Power Cove
Power Cove provides easy table top accessibility andvoice/data connections in a small footprint. Doors areavailable in metal, glass and grain-matched wood. Theinterior is anodized aluminum.
PowerCove is equipped with the following components:
• Power infeed (plug-in only)• Two (2) simplex receptacles• Two (2) RJ-45 (data) connectors (Category 5e) with
removable faceplate• One (1) RJ-11 (voice) connector with removable faceplate• One (1) convenience outlet below work surface
Power Cove Plug-N-Play option includes:
• Two (2) 10’ data supply cords (Category 5e)• One (1) 10’ voice supply cord• Nylon sheath
Power Cove
Power Infeed
Power Coves connected viaconvenience outlet
Power In-feed
Plug-N-Play Option
Voice/Data Jacks withRemovable Faceplates
SimplexReceptacles
Convenience Outlet
Faceplate Options
COVE-FNG1Open Slot Faceplate
COVE-FNG2Double Open Slot Faceplate
COVE-VGA1VGA Connector Faceplate
COVE-USB1USB Connector Faceplate
COVE-RCA1Single RCA Connector Faceplate
COVE-RCA2Double RCA Connector Faceplate
Power Cove features optional faceplates for differenttechnology accommodation such as VGA, USB, andRCA connectors.
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
261W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Power and Voice/Data Capabilities
Power Cove is available on all Nucraftconference table collections as well asSaber Training tables.
5.5"
5.5"
Maximum Simplex Voice/DataTable Quantity Receptacles Receptacles ConvenienceLength Units Provided Provided Outlets
42-72" diam. 1 2 3 172" 1 2 3 184" 1 2 3 196" 3 6 9 3120" 3 6 9 3144" 4 8 12 4168" 4 8 12 4192 4 8 12 4216 6 12 18 6240 6 12 18 6
Dimensions
Power Planning Power Cove Electrical System
• Two (2) simplex receptacles provided per unit.• 15-amp power infeed (plug-in only) with 10’ cord.• UL listed.
Chicago Electrical Requirements
The city of Chicago may require hardwiring of electrical components. For Chicagoapplications, Nucraft provides a non-powered unit; specific electrical components suchas receptacles must be purchased in the field. Chicago-designated units contain all stan-dard voice/data components.
Other Municipality Electrical Requirements
Other metropolitan areas besides Chicago may have special electrical requirements aswell. Consult a local electrical contractor for proper code compliance information.
Voice/Data Planning Power Cove Plug-N-Play option includes:• Two (2) 10’ data supply cords (Category 5e)• One (1) 10’ voice supply cord• Nylon sheath
Nucraft recommends consulting an audio/visual (AV) integrator for specific assistancewith voice/data planning.
Voice/Data Product Manufacturers
Manufacturer Phone Number Web SiteAMP 1-800-522-6752 www.tycoelectronics.comAvaya 1-866-462-8292 www.avaya.comLeviton 1-800-722-2082 www.leviton.comPanduit 1-800-777-3300 www.panduit.comSiemon 1-860-945-4200 www.siemon.com
End Elevation View
Plan View
262 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
PowerPUP Planning
PowerPUP offers convenient access to power andvoice/data connections. PowerPUP features include apush/push open design that conceals internal compo-nents.
Each PowerPUP is equipped with the following compo-nents:
• Clear or black anodized aluminum• Fluid one touch accessibility• Two (2) Simplexes• 10’ 15-Amp cord• Voice/Data Adapter Kit p/n BE01421 to acceptcouplers & jacks
• UL Listed• Overall dimensions - 4-7/16” x 8-5/16”• USB adaptor not included in standard kit
All electrical components are UL listed.
Power and Voice/Data Capabilities
PowerPUP is available on all conference tables includingDuomo Open Sight Line Tables, Satellite, Saber Trainingtables and the Moment Island Bench. Refer to individualproduct sections for specific PowerPUP applicationguidelines.
Voice/Data Planning
Two (2) simplex voice/data cutouts acceptcustomer supplied, field-installed snap-in connec-tors.
Nucraft recommends consulting an audio/visual(AV) integrator for assistance with voice/dataplanning.
Voice/Data Product Manufacturers
Manufacturer Phone Number Web SiteAMP 1-800-522-6752 www.tycoelectronics.comAvaya 1-866-462-8292 www.avaya.comLeviton 1-800-722-2082 www.leviton.comPanduit 1-800-777-3300 www.panduit.comSiemon 1-860-945-4200 www.siemon.com
4-7/16"
4"
8"
1"
8-5/16"
Cover Closed
Maximum Simplex Voice/DataTable Quantity Receptacles SimplexLength Units Provided Cutouts
42"-72" diam. 1 2 272" 3 6 684" 3 6 696" 3 6 6120" 3 6 6144" 3 6 6168" 3 6 6192" 3 6 6216" 3 6 6240" 4 8 8
Cover Open
BENCHES
OCCASIONALTA
BLES
FORTE
TRAINING
PRODUCTS
PRESENTA
TION
PRODUCTS
POWER&
DATA
PLANNING
BOOKCASES&
MODULARSHELVING
263W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
Mini-Port
Mini-Port offers convenient access to power andvoice/data connections. Mini-Ports feature a flip-opendoor that conceals internal components.
Each Mini-Port is equipped with the followingcomponents:
• 15-amp power infeed (plug-in only) with 6’ cord
• Two (2) simplex electrical receptacles
• Two (2) simplex voice/data cutouts (see below forvoice/data planning details)
Power and Voice/Data Capabilities
Mini-Port is available only on Mural. Refer to Muralindividual product pages for specific information (pgs. 225-246).
Voice/Data Planning
Two (2) simplex voice/data cutouts accept customer sup-plied, field-installed snap-in connectors.
Nucraft recommends consulting an audio/visual (AV)integrator for assistance with voice/data planning.
Voice/Data Product Manufacturers
Manufacturer Phone Number Web SiteAMP 1-800-522-6752 www.tycoelectronics.comAvaya 1-866-462-8292 www.avaya.comLeviton 1-800-722-2082 www.leviton.comPanduit 1-800-777-3300 www.panduit.comSiemon 1-860-945-4200 www.siemon.com
3"
2-1/2"
6'
1"
6"
7"
1-3/4"
2"
Mini-Port
Plug-inPower Infeed
Cover Closed
Plug-in Power Infeed
UL Listed.
Mural® Shown
Snap-in Connectors(Customer suplied)
Simplex Receptacle
264 W W W . N U C R A F T . C O M • T O L L F R E E : 1 - 8 7 7 - N U C R A F T
MaximumTable QuantityLength Units
42"-72" diam. 172" 384" 396" 3120" 3144" 3168" 3192" 3216" 3240" 4
Grommet
Round Grommet
Round Grommets are available on all conferencetables, and Saber and Satellite training tables.
Grommets are available in all metal finishes(See Page 8 for specific information) includingClear Anodized (-CA).
Round Grommet Application
Maximum number of grommets available for eachtable size.
3/4"
3"
Forte® Shown
Round Grommet
RemovableAccess Door