ITSM Academy Webinar Process Integration, Metrics and Setting Expectations
Power Conservation Technology Integration Webinar
-
Upload
legend-power -
Category
Business
-
view
1.085 -
download
1
description
Transcript of Power Conservation Technology Integration Webinar
Power Conservation Technology Integration January 28th 2010
Overview1. Strategic Energy Conservation2. Pulse Energy3. Thermonic Electric4. Legend Power 5. Greenfiniti6. Power Conservation Integration7. Incentive Funding Opportunities
a. BOMA CDMb. Revenue Share c. Leasing
8. Question & Answer
Strategic Energy Conservation
• Many different energy conservation technologies available to businesses
• Avoid unproven" Black Box” solutions• Long term strategic approach is needed• Technologies that work together
• Energy Consumption reduced annually• Reduced kWh• Reduced GHG• Reduced Energy Bill
Strategic Energy Conservation
1. Set a Goal: Reduce Energy Consumption2. Contact & Schedule a facility audit:
• Technology Providers• Energy Engineers• Energy Management Companies
3. Review Options• Determine What technologies are best suited for your facility• Five year plan of when to implement different technologies
4. Investigate Funding Opportunities5. Begin Implementing Technologies6. Annual Measurement & Verification
Pulse Energy Management Software
– Collect• Resource consumption data collected in real time from utility or
client-owned meters, BAS / DDC, or sub-meters– Analyze
• Meter data is processed and analyzed at Pulse central servers• Expected consumption curves based on historical data
– Communicate• Web-based view of real-time resource consumption profiles • Instant alerts sent to operations staff when consumption deviates
from expected range• Automated long-term reporting on consumption / cost,
normalized ROI calculations for decision makers
Pulse™ Energy Management Software
Thermonic Electric
• Name: Regulator• Range:
• 2 – 400 kVAR• Network voltage:
• 208v – 600v• Other voltage available
• Type:• Dry or wet
• Phase:• 1 or 3 phase
• Options:• Controller• Blown Fuse pilot lights• Harmonic Filters
Thermonic Electric
• 200, 000 hours lifetime• ROHS Compliant• 0.2W per KVAR losses• Typical payback of 2 years• Indoor, outdoor installation• Operating temperature: -40C to +46C• 7-year warranty
Legend Power• Utilities cannot effectively regulate voltage on the entire grid • Some buildings receive voltage at higher levels than others• High voltage results in:
– energy waste– larger energy bills– unnecessary GHG emissions
Electrical Harmonizer - AVR
126 Volts
118 Volts
Power Generation
Power Distribution Customer
Voltage Optimization
Legend PowerConservation Voltage Regulation• All Electrical Equipment is design
to operate +/- 5% of rated value• Voltage optimization
ensures equipment is operating near the lower limit
• Reduce Energy Consumption by 6-10%
• Real Power Reduction - kW• Reactive Power Reduction
KVar • Energy Consumption
Reduction kWh• Increase the life of Electrical
Equipment• Science World doubled life
expectancy of exterior bulbs
GreenfinitiWHO WE ARE?• Greenfiniti is a joint Canadian-Belgian consulting
and investment firm providing environmental services in the area of climate change mitigation and adaptation.
WHAT WE DO:• Greenfiniti creates and sells your CO2 assets by
demonstrating your project is operating in a way to produce carbon offsets
ASK ME ABOUT:• Our Collaboration with Richard Branson’s
Carbon War Room• www.carbonwarroom.com• Targeting “Low Hanging Fruit” for +1 gigatonne
CO2 reductions: Shipping,Energy Efficiency, Biochar
WHAT CAN WE DO FOR YOU?
Get rewarded for efficiencyPay for capital improvements
Your CO2 savings are an asset and potential revenue stream.
Greenfiniti can help you:***MMM***
1) Measure
2) Manage
3) Monetize
Greenfiniti
• Measure:Produce data for carbon asset. Move through monitoring and verification for *much* less than cost.
• Greenfiniti statistical sampling reduces costs by up to 90%
• Manage: keep track of pre-verification offsets: up to 1mt/yr for a factory.
• Monetize: sell your CO2 assets on the carbon market.
QUALIFYING FOR ENERGY EFFICIENCY OFFSETS:
• The hurdle: Additionality criterion EE projects must show that the revenue from the carbon offsets played a decisive role in making the projects viable.
• The solution: Greenfiniti’s unique CO2 management capabilities and cost savings will make the business case for offsets, and get you over the Additionality hurdle.
Funding Energy Conservation Projects
• BOMA CDM Program• $800/kW or $0.10/kWh• Up to 40% of total project Cost• Quick: Application to Approval to Cash• Currently Limited to Toronto, Ontario• Funded by the Ontario Power Authority
• Many other Electric Utilities or Government bodies offer incentive funding for energy conservation projects
• Revenue Sharing Opportunities• Technology Leasing
Power Conservation Integration
• Incremental Savings:+ Pulse Energy + Legend Power + Thermonic Electric15% - 30% kWh Savings
• Return on Investment• BOMA CDM• Carbon Credits
Questions
Contact Us:• www.legendpower.com• www.pulseenergy.com• www.greenfiniti.com• www.thermonicelectric.com• www.bomacdm.com