Potential Posters for HIMSS11
PCD and Continua; Integration of home, personal and regulated
medical devices
Continua-IHE interoperability standard alignment is an example of medical system and ICT convergence that was precipitated by the global demand for interoperable hospital, eHealth, telemedicine,
and telehealth solutions:• Allows almost any brand of Continua personal health device and/or IHE
clinical (medical) device can be used or interchanged in any appropriate setting;
• TECHNOLOGY can finally assure automatic and accurate data capture and eliminate error-prone manual entry (similar to most other industries like aviation and manufacturing); and
• Can provide near real-time update of Electronic Health Record/Personal Health Record.
NOTE: Must specify the “Continua-WAN” interface for IHE compatibility
IHE-PCD and Continua “live” in two different but overlapping worlds
• Continua – “Personal Health Devices” non-regulated personal appliances, non-life-critical settings like home, car, gym, simple data sets– Personal wellness status, chronic illness home care
• IHE-PCD – Full-on clinical devices and applications, from home chemotherapy through intensive care, implanted devices, and surgery – Becoming MUCH more mobile, including relative acute
care management at the home• Both products must co-exist in the home, with overlapping
missions, different price-points
© 2010 Elliot Sloane, all rights reserved. 4
Beginning this Fall, a single data interface architecture can be used by all Continua Personal Health Devices, all IHE-PCD
Medical Devices, and all IHE EHRs!
With permission, Continua AllianceWith permission, Continua Alliance
Continua and IHE-PCDCollaborative solutions!
• The Continua Health Alliance focuses on “Personal Health Devices,” principally oriented towards non-life-critical health and wellness management outside of hospital settings– Primarily focused on gathering chronic disease diagnostic
health data, and wellness monitoring data, into Personal Health Records www.ContinuaAlliance.org
• The IHE Patient Care Device Domain deals with all clinical settings, life-critical applications, and chronic disease diagnosis and treatment (acute/intensive care, surgery, implants, physician offices, and home care) – Focused on device safety and integrating data into Electronic
Medical Records/Electronic Health Records and Personal Health Records www.IHE.net/PCD
IHE Patient Care Device Clinical Areas
CPOE/ Pharmacy System
Ventilation/Anesthesia
System
ACM, DEC, WCM
Physiologic Monitoring
System
ACM, DEC, WCM
ACM, DEC, WCM
Clinical Decision Support System
Barcode Medication
Administration System
PIVInfusion
Pump
ACM, DEC
DEC
EMR/EHR
CIS
ACM, DEC, WCM
IDCO
ACM, MEM
Implantable Device
EquipmentManagement
System
CurrentPCD
FuturePCD
Future Non PCD‐
Other Devices
ACM: Alarm Communication ManagementDEC: Device Enterprise Communication
IDCO: Implantable Device – Cardiac – ObservationMEM: Medical Equipment ManagementPIV: Point of Care Infusion Verification‐ ‐
WCM: Waveform Communication Management
32
12
3
4
5
6
7
Home BasedSystems
eHealth & TeleHealth
8
Profiling has emerged as a POWERFUL enabler
• IHE’s and Continua’s “Integration Profiles” take myriad “base standards” such as DICOM, ICD9/10, HL7, or IEEE and “CONSTRAINS THE OPTIONALITIES”– e.g., Each standard has a different (or many different) coding
choices and data structure locations for Date and Time– An Integration Profile specifies the SOLE option to be used
for each standard AND specifies a SOLE Global Standard for “Universal Timekeeping” (typically “internet time”)
The EMBS IEEE 11073.x standards are foundational to both Continua and IHE
IHE’s Rosetta Project maps ALL vendor clinical coding to each other via IEEE 11073
IHE Rosetta Project
• Now over 400 columns of vendor-specific mappings of clinical variables and globally-harmonized UCUM units of measurements– e.g., Every brand of ECG monitor, EHR, or IV pump
can “know” the kinds of data that other branded products might send, and can therefore translate that information correctly
– This is ESSENTIAL for life-critical data preservation, interpretation, and, ultimately, closed-loop multi-vendor systems
All IHE and IHE-PCD profiles are FREE to download and use
• www.IHE.net and www.IHE.net/PCD
• Continua Alliance profiles are proprietary, and require membership in the Community
For further informationIntegrating the Healthcare EnterpriseIHE Web: www.ihe.net PCD Web: www.ihe.net/pcd and www.accenet.org/ihe
Wiki: http://wiki.ihe.net/index.php?title=Patient_Care_Device
PCD Getting Started: http://wiki.ihe.net/index.php?title=PCD_Getting_Started
PCD Users’ Handbook: http://www.ihe.net/Resources/handbook.cfm
Continua Health AllianceWeb: http://www.continuaalliance.org
Continua Wiki: http://en.wikipedia.org/wiki/The_Continua_Health_Alliance
Continua Overview Presentation, Video, Flyers: http://www.continuaalliance.com/about-the-alliance.html
National Institute of Standards and TechnologyWeb: http://www.nist.gov
Medical Devices: http://www.nist.gov/medicaldevices