Portfolio Anavach structural engineer

20
ALESSANDRO NAVACH PORTFOLIO PORTFOLIO PORTFOLIO PORTFOLIO Structural engineer Structural engineer Structural engineer Structural engineer Buildings and civil structures Buildings and civil structures Buildings and civil structures Buildings and civil structures

description

 

Transcript of Portfolio Anavach structural engineer

Page 1: Portfolio Anavach structural engineer

ALESSANDRO NAVACH

PORTFOLIOPORTFOLIOPORTFOLIOPORTFOLIO Structural engineerStructural engineerStructural engineerStructural engineer

Buildings and civil structuresBuildings and civil structuresBuildings and civil structuresBuildings and civil structures

Page 2: Portfolio Anavach structural engineer

LIST OF PROJECTS

SEAS srl pag.4

YEAR 2005-2010

Place Airport of CROTONE (Italy)

CLIENT ENAV spa

PROJECT Realization of New control tower and

officies

COST OF WORKS 5.900.000,00 €

MISSION Preliminary, final, detailed design,

supervision of works

My role calculation of new r.c. and steel structures

according to Italian Rules

SEAS srl pag.6

YEAR 2005-2014

Place Airport of Lampedusa (Italy)

CLIENT ENAV spa

PROJECT Realization of New control tower and

officies

COST OF WORKS 5.400.000,00 €

MISSION Preliminary, final, detailed design,

supervision of works

My role calculation of new r.c. and steel structures

according to italian rules

SEAS srl pag.8

YEAR 2006-2009

Place Airport of Palermo (Italy)

CLIENT ENAV spa

PROJECT Realization of New control tower and

officies

COST OF WORKS 12.800.000,00 €

MISSION Preliminary, final, detailed design,

My role calculation of new r.c. and steel structures

according to italian rules

SEAS srl pag.10

YEAR 2002-ongoing

Place Airport of Dushanbè (Tajikistan)

CLIENT ENAV spa

PROJECT Realization of New control tower and

officies

COST OF WORKS 3.800.000,00 €

MISSION Preliminary, final, detailed design,

My role calculation of new r.c. and steel structures

according to eurocodes

Page 3: Portfolio Anavach structural engineer

SEAS srl pag.12

YEAR 2009-2010

Place Catania (Italy)

CLIENT ENAV spa

PROJECT Realization of steel shelters for temporary

officies

COST OF WORKS 749.000,00 €

MISSION Preliminary, final, detailed design,

supervision of works

My role calculation of r.c. and steel structures

according to Italian Rules

SEAS srl pag.14

YEAR 2011-2012

Place Reggello (Italy)

CLIENT Istituto degli innocenti

PROJECT rehabilitation of an ancient country house

into a health center for people with

disabilities

COST OF WORKS 2.700.000,00 €

MISSION Preliminary, final design,

My role calculation of masonry structures

(evaluation of existing structures and

project of retrofitting) according to Italian

Rules

SEAS srl pag.16

YEAR 2006-ongoing

Place Catania(Italy)

CLIENT ENAV spa

PROJECT seismic retrofitting and extension of offices

COST OF WORKS 2.900.000,00 €

MISSION Preliminary, final detailed design,

supervision of works

My role calculation of R.c. structures (evaluation of

existing structures and project of

retrofitting, project of new structures)

according to Italian Rules

LIST OF PROJECTS

Page 4: Portfolio Anavach structural engineer

LIST OF PROJECTS

SEAS srl pag.4

YEAR 2011

Place —

CLIENT SELEX SI (Finmeccanica group)

PROJECT Realization of Radar towers

COST OF WORKS —-

MISSION Preliminary, and final, design

My role calculation steel structures according to

Eurocodes

Page 5: Portfolio Anavach structural engineer

4

AIR

PO

RT CONTROL TOWER AND OFFICES

Crotone, Italy

Page 6: Portfolio Anavach structural engineer

5

Page 7: Portfolio Anavach structural engineer

6

AIR

PO

RT CONTROL TOWER AND OFFICES

Lampedusa, Italy

Page 8: Portfolio Anavach structural engineer

7

4.60

M2

0 1 2 5 10

6.05

3.80

6.35

1.75

2.60

N

1.40

Page 9: Portfolio Anavach structural engineer

8

AIR

PO

RT CONTROL TOWER AND OFFICES

Palermo, Italy

Page 10: Portfolio Anavach structural engineer

9

+2.47 m

RIP.• • •• ••••••

+0.60 m

2829303132333435363738384041424344

4546

4748

49

+0.60 m

+2.98 m

+0.60 m

B

A

A

-1.61 m

14 15 16 17 18 19 20 21 22 23 24 25 26

+0.60 m

27

28

29

31

32

34

35

36

37

38

39

CavedioImpianti

40

27

28

29

31

32

34

35

36

37

38

39

40

+2.98 m

N

3031

3233

3435

3637

38

3940414243

4645

44

2928

27

2423

2221

2526

20

B

Page 11: Portfolio Anavach structural engineer

10

ST

RU

CT

UR

E IRON STRUCTURE, CONTROL TOWER Dushanbe, Tajikistan

Page 12: Portfolio Anavach structural engineer

11

Coupe 3_3'échelle 1:50

Page 13: Portfolio Anavach structural engineer

12

AIR

PO

RT TEMPORARY OFFICES

Catania, Italy

Page 14: Portfolio Anavach structural engineer

13

Page 15: Portfolio Anavach structural engineer

14

RE

NO

VA

TIO

NHEALTH CENTER FOR PEOPLE WITH DISABILITIESReggello, Italy

FABBRICATO 2:appartamento per disabilità medio/gravi composto da : soggiorno/cucina, n. 3 camere da letto per 1 assistente e 2 disabili, n. 2 bagno

FABBRICATO 1:Piano terra: ingresso con scala e ascensore; appartamento per disabilità gravi con sala comune e due camere da letto e bagno, per un totale di 3 posti letto (2disabili + 1 assistente); un sala teatro/musica; una sala riunioni/multifunzioni; un laboratorio artigianale; locale tecnico;Primo piano: ufficio amministrativo per 2 persone con archivio e bagno; foresteria con cucina attrezzata, soggiorno/refettorio per 12 persone, n. 4 camere da letto per n. 8 disabili e 1 assistente, due bagni.

FABBRICATO 3:Piano terra: mini appartamento per n. 1 persona con soggiorno/camera e 1 bagno; centrale termica.Primo piano: appartamento per n. 2 persone, composta da 1 soggiorno/cucina, n. 2 camere con un posto letto ciascuna.

NUOVO FABBRICATO (serra e palestra):Palestra max 15 persone, con spogliatoi/docce uomini-donne;Serra

Planimetria generale

cordolo in muratura armata

capochiave

catena d’ancoraggio trave-muratura

barra iniettata con barra a ritiro compensato

cordolo in c.a. 20*18 cm

rete elettrosaldata risvoltata nel cordolo

barre iniettate per collegamento dei solai alle murature

rete elettrosaldata risvoltata nel cordolo

cordolo in c.a.

Per adeguare il fabbricato ai livelli di sicurezza statica e sismica richiesti dalle normative vigenti (NTC08) sono stati privilegiati interventi strutturali non invasivi e compatibili con il suo valore storico-artistico.

Page 16: Portfolio Anavach structural engineer

15

Page 17: Portfolio Anavach structural engineer

16

ST

RU

CT

UR

E STRUCTURAL RENOVATION, OFFICESCatania, Italy

Page 18: Portfolio Anavach structural engineer

17

Page 19: Portfolio Anavach structural engineer

18

ST

RU

CT

UR

E IRON STRUCTURE, RADAR TOWERItaly

Page 20: Portfolio Anavach structural engineer

19