popular size range ½ to 1½ HP, available in Corrosion...

1
LANCASTER LANCASTER SURVIVOR SERIES Survivor 4” Submersible Pumps 2-2LST5007-2 Catalog Section Number of Stages 1 = 115 Volt, Single Phase 2 = 230 Volt, Single Phase 3 = 230 Volt, Three Phase (Additional Voltages Available) 2 = 2 Wire 3 = 3 Wire P = Plastic Discharge Head Plastic Motor Support L = Lancaster Hydro-Force Motor (no letter L) = Franklin Electric Motor S = Stainless Steel Discharge Head Stainless Steel Motor Support SP = Stainless Steel Discharge Head Plastic Motor Support J = 5 GPM L = 7 GPM T = 10 GPM U = 15 GPM W = 22 GPM 50 = 0.50 HP 75 = 0.75 HP 100 = 1.0 HP 150 = 1.5 HP 200 = 2.0 HP 300 = 3.0 HP 500 = 5.0 HP Lancaster Pump offers a broad selection of SURVIVOR 4” submersible well pumps. Horsepower from ½ to 5 HP, with the most popular size range ½ to 1½ HP, available in Corrosion-Resistant Thermoplastic or Super Strength Stainless Steel. Capacity ratings are 5, 7, 10, 15 and 22 gallons per minute with heads as high as 990 feet. INSIDE A PUMP STAGE • Diffuser with stainless steel seal/wear surfaces for upper impeller hub • Impeller eye surrounding lower hub • Stage plate with stainless steel seal/wear surface for impeller eye ASSEMBLED PUMP STAGE • Laminated phenolic thrust washer on top of every stage provides down-thrust protection and axial sealing for the impeller inside the next stage above BREAKDOWN VARIOspeed ® Variable Frequency Drive Advanced solutions for providing constant water pressure Lancaster Pump’s VARIOspeed® series of constant pressure controls are economical, pre-engineered solutions for variable speed pumping applications for booster and irrigation pumps. Energy savings can be achieved by the drive’s ability to automatically adjust the pump speed to maintain a constant pressure as flow demand conditions change in the plumbing system. Including a user-friendly keypad and 4-line LCD back- lit display, the interface is designed with the pump end user in mind. Programming parameters use pump terminology to allow non-VFD experts a greater comfort level with the drive. The controls are designed using a single factory-programmed variable frequency drive with indoor or indoor/outdoor rated enclosures. TECHNICAL SPECIFICATIONS: Available HP Range (208V/240V) 1.5 HP – 10HP standard models (480V) 7.5HP – 10HP standard models Models available for single phase or three phase power supply Larger models (up to 20HP) available – contact factory 6 www.LancasterPump.com • 1-800-442-0786 Part Number Description Output Amps HP Input Phase Output Phase Weight (lbs.) 1045427 VARIOspeed® N1, 240V 7.0 1.5 1 3 21 1045431 VARIOspeed® 3R, 240V 31 1045428 VARIOspeed® N1, 240V 10.0 3 1 3 22 1045432 VARIOspeed® 3R, 240V 32 1045429 VARIOspeed® N1, 240V 16.5 5 3 3 21 1045433 VARIOspeed® 3R, 240V 31 1045430 VARIOspeed® N1, 240V 31.8 7.5-10 3 3 31 1045434 VARIOspeed® 3R, 240V 35 1045846 VARIOspeed® N1, 480V 16.0 7.5-10 3 3 31 1045845 VARIOspeed® 3R, 480V 47 HP rating is used for indication only, use nameplate amps for sizing. Factory will assist in pump selection VARIOSPEED ® CONSTANT PRESSURE CONTROLLER FEATURES & BENEFITS: Easy to read 4-Line/20 character back lit LCD display and rotary/push button for quick menu navigation and programming. Green LED Run indicator, Red LED Fault indicator, OFF/AUTO selector switch. Motor Protection for Output Phase Loss, Ground Fault, Motor Overload and Motor Over Temperature. Drive Protection for Over Voltage, Input Phase Imbalance, Under Voltage and Short Circuit. Enclosure Style VARIOspeed® N1 – NEMA1 indoor enclosure VARIOspeed® 3R – NEMA 3R indoor/outdoor enclosure Pressure Transducer 0-200 PSI, NEMA 4x rated, stainless steel, ¼” NPT connection, 20 ft. shielded cable Low pressure (pipe burst run dry) protection. High pressure protection. System fault log. Automatic System Restart: the VFD can be configured to automatically restart in Auto Mode after power loss, power spikes, brown outs and dry well condition. VFD arrives pre-programmed. Soft start reduces mechanical/electrical stress, prolonging pump and motor life.

Transcript of popular size range ½ to 1½ HP, available in Corrosion...

LANCASTERLANCASTER

SURV

IVO

R SERIES

SURVIVOR 4” SUBMERSIBLE PUMP MODEL NUMBER BREAKDOWN

Survivor 4” Submersible Pumps

2-2LST5007-2Catalog Section

Number of Stages

1 = 115 Volt, Single Phase 2 = 230 Volt, Single Phase 3 = 230 Volt, Three Phase (Additional Voltages Available)

2 = 2 Wire 3 = 3 Wire

P = Plastic Discharge Head Plastic Motor Support

L = Lancaster Hydro-Force Motor (no letter L) = Franklin Electric Motor

S = Stainless Steel Discharge Head Stainless Steel Motor Support

SP = Stainless Steel Discharge Head Plastic Motor Support

J = 5 GPM L = 7 GPM

T = 10 GPM U = 15 GPM

W = 22 GPM

50 = 0.50 HP 75 = 0.75 HP 100 = 1.0 HP 150 = 1.5 HP 200 = 2.0 HP 300 = 3.0 HP 500 = 5.0 HP

Lancaster Pump offers a broad selection of SURVIVOR 4” submersible well pumps. Horsepower from ½ to 5 HP, with the most popular size range ½ to 1½ HP, available in Corrosion-Resistant Thermoplastic or Super Strength Stainless Steel. Capacity ratings are 5, 7, 10, 15 and 22 gallons per minute with heads as high as 990 feet.

INSIDE A PUMP STAGE• Diffuser with stainless steel seal/wear surfaces for upper impeller hub

• Impeller eye surrounding lower hub

• Stage plate with stainless steel seal/wear surface for impeller eye

ASSEMBLED PUMP STAGE• Laminated phenolic thrust washer on top of every stage provides

down-thrust protection and axial sealing for the impeller inside the next stage above

BREAKDOWN• Glass-filled Noryl® Discharge Head with field replaceable fluted

Internal Check Valve. Molded jug handles - no need for safety cable adapter, ½ HP thru 1½ HP models. Available in Stainless Steel up to 5 HP.

• Fluted Polyurethane Bearing at top end of shaft. Excellent abrasion and wear resistance.

• Stainless Steel Cable Guard for maximum cable protection. Attached with stainless steel screws.

• Balanced Teflon® impregnated Impellers made of glass-filled thermoplastic, provide for lower friction for longer pump life.

• Stainless steel Hex Shaft with slotted end for test turning.

• Fully enclosed, glass-filled thermoplastic Diffusers and Stage Plates with stainless steel wear surfaces. Each stage is complete with an individual composite thrust washer for extra protection.

• Heavy wall, high quality Stainless Steel Pump Casing sized inside for perfect stage alignment.

• Glass-filled Noryl® Motor Support ½ HP thru 1 ½ Hp models. Available in Stainless Steel up to 5 HP.

• Stainless Steel screen, cannot snap off during installation.

VARIOspeed® Variable Frequency DriveAdvanced solutions for providing constant water pressureLancaster Pump’s VARIOspeed® series of constant pressure controls are economical, pre-engineered solutions for variable speed pumping applications for booster and irrigation pumps. Energy savings can be achieved by the drive’s ability to automatically adjust the pump speed to maintain a constant pressure as flow demand conditions change in the plumbing system. Including a user-friendly keypad and 4-line LCD back-lit display, the interface is designed with the pump end user in mind. Programming parameters use pump terminology to allow non-VFD experts a greater comfort level with the drive. The controls are designed using a single factory-programmed variable frequency drive with indoor or indoor/outdoor rated enclosures.

TECHNICAL SPECIFICATIONS:Available HP Range• (208V/240V) 1.5 HP – 10HP standard models• (480V) 7.5HP – 10HP standard models• Models available for single phase or three phase power

supply• Larger models (up to 20HP) available – contact factory

X-Factor Series LXFILTERS AND NEUTRALIZERS

ACID NEUTRALIZERS, FILTERSLancaster’s acid neutralizers correct low pH water, which in turn protects your pipes, faucets, heaters, boilers and all appliances requiring the use of water. A water softener may also be recommended to remove hardness.

SEDIMENT/TURBIDITY (FILTER-AG)Lancaster’s sediment filters will remove dirt, silica, and most suspended matter from your water supply down to a 20 micron filtering level. Filter AG requires no chemical regenerents - just a simple, periodic backwash.

CARBON FILTERSLancaster’s carbon filters, through filtration and adsorption, remove organic chemicals and other contaminants which cause color, taste and odor problems.

IRON FILTERS; BIRM & MTMLancaster’s iron filters remove iron and manganese, also filter other suspended matter, prevent rust stains on clothing, appliances and remove taste and color of iron. When sulfur is present, MTM is the recommended mineral.

Model Number Tank Service GPM Backwash GPM

Color, Taste & Odor (Carbon) Filters Cont. Peak

7-LXCT-1B 10x44 5 8 6.5

7-LXCT-2B 13x48 7 9 10

7-LXCT-3B 14x65 10 12 10

Acid Neutralizer (Calcite) Filters

7-LXDAN-1B 10x47 (with dome plug) 5 8 6.5

7-LXDAN-1.5B 10x54 (with dome plug) 6 9 6.5

7-LXDAN-2B 13x48 (with dome plug) 7 10 10

7-LXDAN-3B 13x65 (with dome plug) 10 12 10

Sediment/Turbidity (Filter AG) Filters

7-LXST-1B 10x44 5 8 5.3

7-LXST-2B 13x48 7 9 9

7-LXST-3B 14x65 10 12 9

Iron (Birm) Filters

7-LXIM-1B 10x44 5 8 6.5

7-LXIM-2B 13x48 7 9 10

7-LXIM-3B 14x65 10 12 10

Iron (MTM) Filters

7-LXTPIM-1B 10x44 5 8 6.5

7-LXTPIM-2B 13x48 7 9 11

7-LXTPIM-3B 14x65 10 12 11

Note: When using Birm for iron removal, it is necessary that the water contain no oil or hydrogen sulfide, organic matter not to exceed 4-5ppm, the D.O. content equal at least 15% of iron content with a pH of 6.8 or more. If the influent water has a pH of less than 6.8, neutralizing additives such as calcite, corosex or soda ash may be used prior to the Birm filter to raise the pH. A water having a low D.O. level may be pretreated by aeration. Chlorination greatly reduces Birm’s activity. High concentrations of the chlorine compounds may deplete the catalytic coating.

WAT E R T R E AT M E N TLANCASTER •

www.LancasterWaterTreatment.com • 1-800-442-0786May 2016

DIAMOND LINE LX

– FILTERS & NEUTR

ALIZERS

www.LancasterPump.com • 1-800-442-0786

Part Number Description Output Amps HP Input Phase Output Phase Weight (lbs.)1045427 VARIOspeed® N1, 240V

7.0 1.5 1 321

1045431 VARIOspeed® 3R, 240V 311045428 VARIOspeed® N1, 240V

10.0 3 1 322

1045432 VARIOspeed® 3R, 240V 321045429 VARIOspeed® N1, 240V

16.5 5 3 321

1045433 VARIOspeed® 3R, 240V 311045430 VARIOspeed® N1, 240V

31.8 7.5-10 3 331

1045434 VARIOspeed® 3R, 240V 351045846 VARIOspeed® N1, 480V

16.0 7.5-10 3 331

1045845 VARIOspeed® 3R, 480V 47HP rating is used for indication only, use nameplate amps for sizing. Factory will assist in pump selection

LANCASTERLANCASTER

SURV

IVO

R SERIES

SURVIVOR 4” SUBMERSIBLE PUMP MODEL NUMBER BREAKDOWN

Survivor 4” Submersible Pumps

2-2LST5007-2Catalog Section

Number of Stages

1 = 115 Volt, Single Phase 2 = 230 Volt, Single Phase 3 = 230 Volt, Three Phase (Additional Voltages Available)

2 = 2 Wire 3 = 3 Wire

P = Plastic Discharge Head Plastic Motor Support

L = Lancaster Hydro-Force Motor (no letter L) = Franklin Electric Motor

S = Stainless Steel Discharge Head Stainless Steel Motor Support

SP = Stainless Steel Discharge Head Plastic Motor Support

J = 5 GPM L = 7 GPM

T = 10 GPM U = 15 GPM

W = 22 GPM

50 = 0.50 HP 75 = 0.75 HP 100 = 1.0 HP 150 = 1.5 HP 200 = 2.0 HP 300 = 3.0 HP 500 = 5.0 HP

Lancaster Pump offers a broad selection of SURVIVOR 4” submersible well pumps. Horsepower from ½ to 5 HP, with the most popular size range ½ to 1½ HP, available in Corrosion-Resistant Thermoplastic or Super Strength Stainless Steel. Capacity ratings are 5, 7, 10, 15 and 22 gallons per minute with heads as high as 990 feet.

INSIDE A PUMP STAGE• Diffuser with stainless steel seal/wear surfaces for upper impeller hub

• Impeller eye surrounding lower hub

• Stage plate with stainless steel seal/wear surface for impeller eye

ASSEMBLED PUMP STAGE• Laminated phenolic thrust washer on top of every stage provides

down-thrust protection and axial sealing for the impeller inside the next stage above

BREAKDOWN• Glass-filled Noryl® Discharge Head with field replaceable fluted

Internal Check Valve. Molded jug handles - no need for safety cable adapter, ½ HP thru 1½ HP models. Available in Stainless Steel up to 5 HP.

• Fluted Polyurethane Bearing at top end of shaft. Excellent abrasion and wear resistance.

• Stainless Steel Cable Guard for maximum cable protection. Attached with stainless steel screws.

• Balanced Teflon® impregnated Impellers made of glass-filled thermoplastic, provide for lower friction for longer pump life.

• Stainless steel Hex Shaft with slotted end for test turning.

• Fully enclosed, glass-filled thermoplastic Diffusers and Stage Plates with stainless steel wear surfaces. Each stage is complete with an individual composite thrust washer for extra protection.

• Heavy wall, high quality Stainless Steel Pump Casing sized inside for perfect stage alignment.

• Glass-filled Noryl® Motor Support ½ HP thru 1 ½ Hp models. Available in Stainless Steel up to 5 HP.

• Stainless Steel screen, cannot snap off during installation.

VA

RIOSPEED

® C

ON

STAN

T PRESSURE CO

NTRO

LLER

FEATURES & BENEFITS:• Easy to read 4-Line/20 character back lit LCD display

and rotary/push button for quick menu navigation and programming.

• Green LED Run indicator, Red LED Fault indicator, OFF/AUTO selector switch.

• Motor Protection for Output Phase Loss, Ground Fault, Motor Overload and Motor Over Temperature.

• Drive Protection for Over Voltage, Input Phase Imbalance, Under Voltage and Short Circuit.

Enclosure Style• VARIOspeed® N1 – NEMA1 indoor enclosure• VARIOspeed® 3R – NEMA 3R indoor/outdoor

enclosurePressure Transducer• 0-200 PSI, NEMA 4x rated, stainless steel, ¼” NPT

connection, 20 ft. shielded cable

• Low pressure (pipe burst run dry) protection.• High pressure protection.• System fault log.• Automatic System Restart: the VFD can be configured

to automatically restart in Auto Mode after power loss, power spikes, brown outs and dry well condition.

• VFD arrives pre-programmed.• Soft start reduces mechanical/electrical stress,

prolonging pump and motor life.