20.002 POINT INTEGRATING BOTTLE
Approval Date: 20 May 1998
Reviewed on : 23 October 2007 Version: 1
Equipment Specification: POINT INTEGRATING BOTTLE Version 1 20.002-1/2
Purpose
The suspended sediment sampler is for manually taking of point integrated samples in rivers,canals and reservoirs.
Introduction
The bottle sampler is a point-integrating device. The current practice in most states of theIndian Peninsula is to use the “Punjab” bottle sampler for measuring suspended load. Thesampler is designed for rivers with suspended load almost exclusively composed of washload, with no or little coarse and medium particle size fractions. The measurement procedurewith this instrument is described in several documents, though no real standard procedureseems to be adopted. There are no clear or uniform guidelines for adopting one or anotherprocedure on the basis of the flow and the sediment characteristics of the river at themeasurement section.
Conditions & Requirements
• The sampler shall have a streamlined body.• No bolts or other parts, other then for taking the sample, shall protrude from the body.• The sample shall remain intact while hoisting the sampler.• The sampler shall have a well established and proven correction factor.• Spares and tools required for routine maintenance shall be part of the delivery.• The standard list of spare parts needed for one year operation shall be listed and
quotation given.A wading rod, designed to hold the hand-held sampler at the required sampling depth.
Specifications
water velocity up to 1.5 m/swater depth up to 2.5 moperation manuallyunmeasured depth 0.10 m maximum sampling distance from the bottommass (without sample) 5 kg max
Wading rodpurpose to submerse the sampler to the required depthdiameter 0.02 to 0.03 mlength 2.5 mcontainer holder at lower end
Corkcontrol by handgrip
Features
• Rigid sample container, easily replaceable
20.002 POINT INTEGRATING BOTTLEAs per HP-I
Approval Date: 20 May 1998 Version: 1
Equipment Specification: POINT INTEGRATING BOTTLE Version 1 20.002-2/2
Purpose
The suspended sediment sampler is for manually taking of point integrated samples in rivers,canals and reservoirs.
Introduction
The bottle sampler is a point-integrating device. The current practice in most states of theIndian Peninsula is to use the “Punjab” bottle sampler for measuring suspended load. Thesampler is designed for rivers with suspended load almost exclusively composed of washload, with no or little coarse and medium particle size fractions. The measurement procedurewith this instrument is described in several documents, though no real standard procedureseems to be adopted. There are no clear or uniform guidelines for adopting one or anotherprocedure on the basis of the flow and the sediment characteristics of the river at themeasurement section.
Conditions & Requirements
• The sampler shall have a streamlined body.• No bolts or other parts, other then for taking the sample, shall protrude from the body.• The sample shall remain intact while hoisting the sampler.• The sampler shall have a well established and proven correction factor.• Spares and tools required for routine maintenance shall be part of the delivery.• The standard list of spare parts needed for one year operation shall be listed and
quotation given.A wading rod, designed to hold the hand-held sampler at the required sampling depth.
Specifications
water velocity up to 1.5 m/swater depth up to 2.5 moperation manuallyunmeasured depth 0.10 m maximum sampling distance from the bottommass (without sample) 5 kg max
Wading rodpurpose to submerse the sampler to the required depthdiameter 0.02 to 0.03 mlength 2.5 mcontainer holder at lower end
Corkcontrol by handgrip
Features
• Rigid sample container, easily replaceable