POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform...

18
POCT Innovations Dual Path Platform (DPP®) Technology www.chembio.com

Transcript of POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform...

Page 1: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

POCT – Innovations

Dual Path Platform (DPP®)

Technologywww.chembio.com

Page 2: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

National Institutes of Health – NIH

Centers for Disease Control & Prevention- CDC

The Foundation for Innovative & Novel Diagnostics- FIND

The Infectious Disease Research Institute- IDRI

The Pan American Health Organization-PAHO

World Health Organization-WHO

Fundação Oswaldo Cruz– FIOCRUZ

Guidelines + Standards+ Colaboration = Sucess

Page 3: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

National Hospital Abuja, Nigeria

Journal Diagnostic Microbiology & Infection Disease

Page 4: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

ORAL FLUID - HIV/AIDS IN NIGERIA

FACTS & NEEDSEndemic + StigmatizationReliable rapid testing kits & ProcedureIncrease uptake of services

STUDY AIM2004/2005 – False Positive - CDC Intervention

HIV antibodies in Blood Oral FluidSensitivity & Specificity of DPP

ConfirmatoryDetermine

Western Blot ( Discordant Cases)

Page 5: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Total = 645 Patients

National Hospital Abuja, Nigeria

Fall 2009

Chembio DPP® HIV 1/2 Screening AssayOral Fluid & Fingerstick Blood

228

Low

Risk

215

HIV Pos

202

High

Risk

SENSITIVITY SPECIFICITY

Oral Fluid = 100%

Fingertip Blood = 100%

Oral Fluid = 100%

Fingertip Blood = 99.5%

Page 6: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Oral Fluid

n=645

Fingertip Blood

n=643

True

Positive1

223 221

False

Positive

0 2

True

Negative1

422 422

False

Negative

0 0

Sensitivity 100% (95% CI =

98.3% - 100%)

100% (95% CI = 98.3% - 100%)

Specificity 100% (95% CI =

99.1% - 100%)

99.5% (95% CI = 98.3% 99.9%)

Table 1: Oral Fluid and Whole Blood Study –

Nigeria, 20091Confirmation performed by reference test and / or

Western Blot

Page 7: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

SWAB

ORAL FLUID

FINGERPRINTSTICK

WHOLE BLOOD

SAMPLING

PHLEBOTOMY

WHOLE BLOOD

SERUM

PLASMA

Page 9: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

POCT Improvement DPP

• Increased analytical and clinical sensitivity

• Outside the standard lateral flow

• Less labor intensive than EIA, PCR or WB

• Potential ideal confirmatory test

• Adaptable to multiple sample types: blood serum, oral fluid, sputum urine, feces, etc.

• Multiplex capability through elimination of aggregation issues (ie HIV/TB, HIV 1/ 2, etc.)

• Requires minimal sample volume

• Long shelf life (up to 24 months)

• Total test time < 20 minutes

• Ideally suited for POC testing

Page 10: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Analytical & Clinical Sensitivity > 10 X Conventional Lateral Flow

• Independent Flow Path for Sample and Conjugate

• Increased Efficiency of Binding Antibody To Immobilized Test

Antigen In The Absence Of Competing Conjugate

• Enhanced Capacity of Conjugate To Bind Specific Antibody In

The Absence of Irrelevant IgG

Sample Delivery For All Sample Types ImprovedBlood, Serum, Oral Fluid, Sputum, Feces & Urine

Multiple Parameter Tests More Feasible Due to Independent & Simultaneous Delivery Of Sample

For example: Serological Test For Multiple Disease (HIV, TB, Syphilis, HCV); Confirmatory Test For HIV (P24, Gp41, Gp120, Gp160, Gp36)

Improvement Over Antigen Detection Tests That Use Complex Sandwich System

Such As Strepavidin/Biotin Or Rapid PCR Test (Flu/RSV, Cardiac Marker, Bio Defense)

Freedom to Operate

Chembio DPP™ Technology - Advantages

Page 11: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Dual Path Platform (DPP®) Technology

WHOLE BLOOD

ORAL FLUID

IN USE : DOMINICA & ST KITTS AND NEVIS

Page 12: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Ag1

Ag2

Ag3

No

n H

IV a

ntib

od

ies

HIV

an

tib

od

ies

gold

goldgold

gold

gold

Test Line Control Line

S1 strip

S2 strip

PAPA

PAPA

PAPA

PAPA

PAPA

PAPA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PA

PAPA

PA

PA

PAPA

PA

PAPA

gold

gold

gold

gold

gold

Antibodies

in sample

Pro

tein

A g

old

co

nju

gate

PA

= P

rote

in AH

IV A

ntig

en

s

DPP™ HIV 1/2

Page 13: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

DPP HCV/HIV/Syphilis Assay

1 2 3 C

1- HCV

2- Syphilis

3- HIV

C- Control

HCV, HIV and Syphilis

Positive

Page 14: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

1

H

I

V

2

H

C

V

3

S

Y

P

H

I

L

I

S

4

C

O

N

T

R

O

L

Page 15: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive
Page 17: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Chembio-Branded Public Health Base

Complemented by OEM and License Programs

17

Current OEM/Licensees

Anticipated OEM/License Areas

Page 18: POCT Innovations Dual Path Platform (DPP®) Technology · POCT –Innovations Dual Path Platform ... Centers for Disease Control & Prevention- CDC ... 2004/2005 –False Positive

Talita FrancoInternational Business Consultant

Chembio Diagnostic Systems Inc

Tel/Fax:+1(951)239-3139

E.mail: [email protected]

Skype: tsallesusa

Homepage: www.chembio.com