POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE...

37
POCKET GUIDE Rheem-Ruud Commercial water heaters Tanktype Gas & Electric Hot Water Supply Heaters Indirect Storage Tanks Commercial water heaters from Rheem-Ruud Technical Service ...................................800-HEATER3 U.S. Customer Service ............................800-621-5622 U.S. Fax ...................................................800-535-9538 Canada Customer Service ......................800-268-6966 Canada Fax..............................................800-200-5393 Website ........................................................rheem.com Rheem Water Heating and Heating & Cooling Products 101 Bell Road • Montgomery, AL 36117-4305 www.rheem.com Rheem manufactures residential and commercial heating & cooling and water heating products. Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 • Brampton, Ontario, L6Y 0P5 Not all models are available in Canada. Printed in U.S.A. 03/10 WP Form No. RR105-2 Rev. 27 In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.

Transcript of POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE...

Page 1: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

POCKET GUIDE

Rheem-Ruud Commercialwater heaters

• Tanktype Gas & Electric • Hot Water Supply Heaters • Indirect • Storage Tanks

Commercial water heatersfrom Rheem-Ruud

• Technical Service ...................................800-HEATER3• U.S. Customer Service ............................800-621-5622• U.S. Fax ...................................................800-535-9538• Canada Customer Service ......................800-268-6966• Canada Fax..............................................800-200-5393• Website ........................................................rheem.com

Rheem Water Heating and Heating & Cooling Products101 Bell Road • Montgomery, AL 36117-4305www.rheem.com

Rheem manufactures residential and commercial heating & cooling and water heating products.

Rheem Canada Ltd./Ltée125 Edgeware Road, Unit 1 • Brampton, Ontario, L6Y 0P5Not all models are available in Canada. Printed in U.S.A. 03/10 WP Form No. RR105-2 Rev. 27

In keeping with its policy of continuous progress and product improvement,Rheem-Ruud reserves the right to make changes without notice.

Page 2: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

COMMERCIAL GAS WATER HEATERS

SPIDERfire Models GHE100-130(A) thru GHE100-350(A)............. 2-3

AdvantagePlus Models HE45-100 thru HE119-199 ........................ 4-5

Universal Models G50-98 thru G100-400(A) ................................... 6-7

Universal Low NOx Models GN75-125 thru GN100-400(A)............ 8-9

Xtreme Models GX90-550(A) thru GX90-715(A)............................. 10-11

VentMaster Power Direct Vent Models GP100-150 & GP100-250(A) 12-13

Induced Draft GD100-250(A) thru GD100-360(A)........................... 14-15

Medium Duty Models G60-50 thru G100-80.................................... 16-17

PowerVent GPV75-75E ................................................................... 18-19

Power Venter Kits ............................................................................ 20-21

COMMERCIAL HOT WATER SUPPLY HEATERS

With Pump GBBP136 thru GBCP1826............................................ 22-23

Without Pump GBB136 thru GBC1826 ........................................... 22-23

COMMERCIAL ELECTRIC WATER HEATERS

Large Volume EVRO, EVS and EHSO Models ............................... 24-25

Heavy Duty ES50, ES85, ES120, E50(A), E85(A) and E120(A)..... 26-27

PowerPack Heavy Duty E12A, E20A, E30A and E40A................... 28-29

Eclipse ............................................................................................. 30-31

Booster E10 ..................................................................................... 32-33

Light Duty Models ELD30 thru ELD120........................................... 34-35

Light Duty Models ELDS30 thru ELDS52........................................ 34-35

Point-of-Use EGSP2 thru EGSP30 ................................................. 36-37

INDIRECT WATER HEATERS ........................................................ 38-39

COMMERCIAL STORAGE TANkS

ST80(A), ST120(A) and ST175(A) .................................................. 40-41

Large Volume Storage Tanks........................................................... 42-43

CertiSpec 3.2 on Internet Download ............................................ 44-45

TABLE OF CONTENTS

A.O. SMITHGas – Tank Type BTR & BTH (Cyclone).......................................... 46-47Gas – Hot Water Supply Heaters BC, HW & DW............................ 48-49Storage Tank Systems TJ, TJV........................................................ 49Electric – Light/Heavy Duty & Boosters DEL, DEN, DRE, DVE, CMC, SU................................................ 50-51

AMERICANGas – Tank Type PVCG32, CG32, DCG32, PVDCG32, DCG31.... 52-53Electric – Light/Heavy Duty LDCE, ITCE,STCE, AITCE, ASTCE.... 54-55Storage Tank Systems CST, ACST.................................................. 55

BRADFORD WHITEGas – Tank Type .............................................................................. 56-57Gas – Hot Water Supply Heaters L-I-T1.......................................... 58-59Storage Tank Systems M-3-ST........................................................ 59Electric – Light/Heavy Duty Booster M-II-SF-CF, LI............................................................................... 60-61

LOCHINVARGas – Tank Type CNR, CNA ........................................................... 62-63Gas – Hot Water Supply Heaters CPN, RWN, CWN ........................................................................ 64-65Storage Tank Systems RJS, RJA .................................................... 65Electric – Light/Heavy Duty & Boosters ETX, ETW, ESX, ETX, SB, HS, HC............................................. 66-67

STATEGas – Tank Type SBT, SBF ............................................................. 68-69Electric – Light /Heavy Duty CPE, SB6 ........................................... 70-71Storage Tank Systems PV ............................................................... 71

COMPETITOR CROSS REFERENCE INDEXDimensions reflect models built prior to 1/20/04.

Page 3: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

2

SPIDERfire® Sealed Combustion Gas-Fired 130,000 – 350,000 BTU/HR.

(On SelectedModels)

(With OptionalKit)

A

B

D

C H GF E

COLD INFRONT

HOT OUTFRONT

DRAINVALVE

T&P

HAND HOLECLEANOUT

COLD INREAR

HOT OUTREAR

EXHAUSTAIR INTAKEGAS INLET

LEFT SIDE RIGHT SIDEFRONT REAR

DRAIN VALVET&PTEMPSENSOR

EXHAUST

INTAKE

TOP VIEW

31°

42°

31°

41°

SPIDERfire Features:

• Maximum thermal efficiency of 95% dramatically reduces operating costs

• No chimney required; power or direct vent using plastic pipe

• Low NOx emissions. Meets SCAQMD Rule 1146.2

• Corrosion resistant, high efficiency 3-pass heat exchanger

• Self-diagnostic LCD electronic control

• Direct spark ignition

• 185° F maximum temperature setting

• Zero clearance to all combustible surfaces

• Full flow drain valve

• Front and back water connectioins

• Factory installed AGA/ASME rated T&P relief valve

RECOVERy CAPACITIES MODEL INPuT (BTu/HR) THERMAL TEMP. RISE – GPH

NuMBER NAT. & LP EFFICIENCy uNITS 40°F 100°F 140°F

GHE100-130(A) 130,000 95% GPH 374 150 107

GHE100-160(A) 160,000 95% GPH 461 184 132

GHE100-200(A) 199,000 95% GPH 573 229 164

GHE100-250(A) 250,000 93% GPH 705 282 201

GHE100-300(A) 300,000 93% GPH 845 338 242

GHE100-350(A) 350,000 92% GPH 976 390 279

DIMENSIONAL INFORMATION All dimensions shown in inches

WATER CONNECTS APPROX.

A B C D E F G H VENT INLET OuTLET SHIP. WT. (LB)*

78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 2, 3, 4 2" NPT 2" NPT 785

78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 2, 3, 4 2" NPT 2" NPT 785

78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 2, 3, 4 2" NPT 2" NPT 785

78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 3, 4 2" NPT 2" NPT 825

78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 3, 4 2" NPT 2" NPT 825

78-3/4 26-1/4† 66 12-3/4 73-3/4 73-5/8 72-7/16 66-7/16 3, 4 2" NPT 2" NPT 825

0" CLEARANCE TO COMBUSTIBLES

MODELS WITH INPUTS OF 130,000 BTU THRU 199,000 BTU ARE CERTIFIED TO VENT WITH 2" SCHEDULE 40 PVC, CPVC OR ABS PIPE

(FOR CANADIAN INSTALLATIONS, PLEASE USE ULC-S636 PVC AND CPVC PIPE.)

3

*Weights listed are for non-ASME. Add 35 lbs. for ASME models.

130,000 - 199,000 BTU models are certified to be installed with 2" venting.

All models require a 120V power source.

See use and care manual for venting details.†Overall width is 27-5/16" due to exhaust cover.

Page 4: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

4

Hot Out

D

Cold In

Electrical

Connection

Gas Inlet

Condensate ConnectionC

E

F

3.75”

B

A

AdvantagePlus Features:

• 316L stainless steel tank construction (requires no anode rods).

• No chimney required; direct ventusing plastic pipe.

• Thermal efficiency of 95% dramatically reduces operatingcosts.

• 85 equivalent feet of vent length.• Low NOx emissions. Meets

SCAQMD Rule 1146.2.• High impact plastic jacket

eliminates dents.• 2” of non-CFC, polyurethane

foam insulation.• Less than 1/2 degree per hour

heat loss (R17).• Corrosion resistant, high

efficiency 90/10 cupronickel heatexchanger.

• Self-diagnostic electronic controlwith digital readout for water temperature, set point and differential.

• Removable front cover allowseasy access to equipment (24"service clearance recommended).

• Temperature range from 70°F to160°F (maximum temperaturesetting of 180°F available onHE55-160 and HE55-199 boostermodels only).

• Zero clearance to all combustible surfaces.

• Factory installed AGA/ASMErated T&P relief valve.

• Booster installation kit providedwith HE55-160 and HE55-199booster models.

(All models require 120V power source.)

AdvantagePlus™ Sealed Combustion Gas 100,000 – 199,000 BTU/HR.

5

RECOVERY CAPACITIES MODEL CAP. INPUT (BTU/HR.) THERMAL TEMPERATURE RISE – DEGREES F – GALLONS PER HOUR NUMBER GALS. NAT. & LP EFFICIENCY 40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140°HE55-100* 55 100,000 95% 288 230 192 165 144 128 115 105 96 N/A N/AHE55-130* 55 130,000 95% 374 299 249 214 187 166 150 136 125 N/A N/AHE80-130* 80 130,000 95% 374 299 249 214 187 166 150 136 125 N/A N/AHE119-130* 119 130,000 95% 374 299 249 214 187 166 150 136 125 N/A N/AHE55-160 55 160,000 95% 461 368 307 263 230 205 184 167 154 142 132HE80-160 80 160,000 95% 461 368 307 263 230 205 184 167 154 N/A N/AHE119-160 119 160,000 95% 461 368 307 263 230 205 184 167 154 N/A N/AHE55-199 55 199,000 95% 573 458 382 327 286 255 229 208 191 176 164HE80-199 80 199,000 95% 573 458 382 327 286 255 229 208 191 N/A N/AHE119-199 119 199,000 95% 573 458 382 327 286 255 229 208 191 N/A N/AThe recovery rate is based on recovery efficiencies obtained in a UL certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures andexceed the thermal efficiency and standby loss requirements of ASHRAE (part of the Federally mandated Energy Policy Act - EPACT). These models also exceed the energy efficiency codes of all states including the California Energy Commission (CEC). All models are North Carolina Code compliant.

DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL WATER CONNECTIONS APPROX. SHIPPING CLEARANCE TO NUMBER A B C D E F VENT INLET OUTLET WEIGHT (LBS.) COMBUSTIBLESHE55-100* 52 23-1/2 32 45 5 25-1/4 2* 1 1 175 lbs. 0 0 0HE55-130* 52 23-1/2 32 45 5 25-1/4 2* 1 1 175 lbs. 0 0 0HE80-130* 72 23-1/2 32 65 5 25-1/4 2* 1-1/2 1-1/2 235 lbs. 0 0 0HE119-130* 73 27 36 66-3/4 6-3/4 28-7/8 2* 1-1/2 1-1/2 405 lbs. 0 0 0HE55-160 52 23-1/2 32 45 5 25-1/4 3 1 1 175 lbs. 0 0 0HE80-160 72 23-1/2 32 65 5 25-1/4 3 1-1/2 1-1/2 235 lbs. 0 0 0HE119-160 73 27 36 66-3/4 6-3/4 28-7/8 3 1-1/2 1-1/2 405 lbs. 0 0 0HE55-199 52 23-1/2 32 45 5 25-1/4 3 1 1 175 lbs. 0 0 0HE80-199 72 23-1/2 32 65 5 25-1/4 3 1-1/2 1-1/2 235 lbs. 0 0 0HE119-199 73 27 36 66-3/4 6-3/4 28-7/8 3 1-1/2 1-1/2 405 lbs. 0 0 0*The models with inputs of 100,000 kBtu and 130,000 kBtu are certified to vent with 2" Schedule 40 PVC, CPVC or ABS pipe. (For Canadian models, vent with 2" ULC-S636 PVC or CPVC pipe)

Use HEC prefix for Canadian models.

The HE55-160 and HE55-199 Booster models are the only models equipped with a 180°F thermostat. Models with 180°F thermostats come standard with the Booster Installation kit which includesall necessary components for an approvedinstallation.

BOOSTER INSTALLATION kIT INCLUDES:

• Nibco Tee – 1" x 1" x 1/2" (2 pieces)• Female Adapter – 1" (2 pieces)• Dial Thermometer (2 pieces)• Expansion Tank – 4-1/2 gallon• Grundfos 3 Speed Pump with Check Valve• Nibco 1.2" x 12" Fitting Air Chamber• Vacuum Relief Valve• Pressure Gauge – 0-200 PSI• Nibco Tee 712R – 1" x 1" x 3/4" (2 pieces)• Nibco Tee 714RR – 1" x 1/2" x 1"• Nibco Tee – 1" x 1/2" x 1" Copper• Reducing Coupling• Pressure Reducing Valve• Nibco Male Adapter – 1"

Page 5: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

6

Universal™ Heavy Duty Gas 98,000 – 400,000 BTU/HR.

C

H

E

ABF

D

OUTLET TOP

INLET TOP

OUTLET FRONT SIDE

OUTLET REAR SIDE

SYSTEM SENTINEL

T&P

INLET FRONT SIDE

INLET REAR SIDE

G

7" (178mm)

(On SelectedModels)

(With OptionalLeg Kit)

Universal Features:

• Small jacket diameters• Short floor-to-vent heights• Multiple water connections• System Sentinel™ LED

diagnostic system

Standard Features:

• 3 year limited tank warranty• Patented multiflue design• Low profile automatic flue

damper• Spark-to-pilot ignition

system• Full port, full flow brass

drain valve

• Factory installed AGA/ASMErated T&P relief valve

• Handhole cleanout• Stainless steel burners• 180° max operating

temperature• LED diagnostics on all damper

assemblies for easier service• Certified for a 150 PSI

maximum working pressure(160 PSI for ASME models)

• Manual reset high limit (ASME models)

• Low NOx models available

RECOVERY CAPACITIESMODEL GAL. INPUT BTU/HR. THERMAL TEMP. RISE - GPHNUMBER CAP. NATURAL & L.P. EFFICIENCY 40° 100° 140°

G50-98 50 98,000 80% 238 95 68

G75-125 75 125,000 80% 303 121 87

G82-156 82 156,000 80% 378 151 108

G76-180 76 180,000 80% 436 175 125

G37-200 35 199,900 80% 485 194 138

G76-200 76 199,900 80% 485 194 138

G91-200 91 199,900 80% 485 194 138

G100-200(A) 100 199,900 80% 485 194 138

G72-250(A) 72 250,000 80% 606 242 173

G100-250(A) 100 250,000 80% 606 242 173

G100-270(A) 100 270,000 80% 654 262 187

G72-300(A) 72 300,000 80% 727 291 208

G85-300(A) 85 300,000 80% 727 291 208

G100-310(A) 100 310,000 80% 752 301 215

G65-360(A) 65 360,000 80% 873 349 249

G65-400(A) 65 399,900 80% 969 388 277

G85-400(A) 85 399,900 80% 969 388 277

G100-400(A) 100 399,900 80% 969 388 277

Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Thermal Efficiency in accordance with ANSI Z21.10.3 labeling requirements. “(A)” Indicates Available ASME Model. *3/4" for L.P. Models. Increase Height 3-5/8" for NSF Models. All Models Require a 120V Power Source.These models have been tested according to ANSI test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). All models are North Carolina Code compliant.

DIMENSIONAL INFORMATION (All dimensions shown in inches) WATER CONNECTIONS APPROX. SHIPPING CLEARANCES TO

TOP FRONT REAR WEIGHT (LBS.) COMBUSTIBLES

A B C D E F G H IN/OUT SIDE SIDE STANDARD ASME SIDE REAR TOP

62-3/4 57-1/8 22-1/2 22-5/8 5 50-1/2 1/2 15 1 1-1/2 1-1/2 270 N/A 2" 2" 12"

65-1/2 61 26-1/4 25 5 56 3/4 20 1-1/2 1-1/2 1-1/2 480 N/A 2" 2" 12"

68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 490 N/A 2" 2" 12"

68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 540 N/A 2" 2" 12"

49-1/4 43-3/8 26-1/4 25 6 37-5/8 3/4 20 1-1/2 1-1/2 1-1/2 405 N/A 2" 2" 12"

68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 540 N/A 2" 2" 12"

76-5/16 71-13/16 26-1/4 30-5/8 6 66-3/8 3/4 20 1-1/2 1-1/2 1-1/2 600 N/A 2" 2" 12"

73-1/16 66-1/8 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 780 835 2" 4" 12"

71-1/16 64-1/2 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 590 630 6" 6" 12"

73-1/4 66-1/8 30-1/4 23-1/4 8 57-1/2 3/4 23 1-1/2 2 2 795 835 2" 4" 12"

73-7/8 66-1/8 30-1/4 23-1/4 8 57-1/2 3/4 23 1-1/2 2 2 805 845 2" 4" 12"

71 64-1/2 26-1/4 25 8 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 590 630 6" 6" 12"

78-7/16 72-5/16 26-1/4 30-5/8 8 66-3/8 3/4 20 1-1/2 1-1/2 1-1/2 640 680 6" 6" 12"

75 68-1/2 30-1/4 32-1/4 7 61-3/4 3/4 23 1-1/2 2 2 770 810 4" 4" 12"

70-11/16 64-1/2 26-1/4 25 8 58-5/8 3/4 N/A N/A 1-1/2 1-1/2 640 680 6" 6" 12"

70-11/16 64-1/2 26-1/4 25 8 58-5/8 3/4 N/A N/A 1-1/2 1-1/2 640 680 6" 6" 12"

78-13/16 72-5/16 26-1/4 30-5/8 10 66-3/8 3/4 20 1-1/2 1-1/2 1-1/2 640 680 6" 6" 12"

76 68-1/2 30-1/4 32-1/4 8 61-3/4 1* 23 1-1/2 2 2 770 810 4" 4" 12"

7

Page 6: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

8

Universal™ Heavy Duty Gas Low NOx 125,000 – 400,000 BTU/HR.

C

H

E

ABF

D

OUTLET TOP

INLET TOP

OUTLET FRONT SIDE

OUTLET REAR SIDE

SYSTEM SENTINEL

T&P

INLET FRONT SIDE

INLET REAR SIDE

G

7" (178mm)

(On SelectedModels)

Universal Features:

• Small jacket diameters• Short floor-to-vent heights• Multiple water connections• System Sentinel™ LED diagnostic

system

Standard Features:

• 3 year limited tank warranty• Patented multiflue design• Low profile automatic flue damper• Spark-to-pilot ignition system• Full port, full flow brass drain valve• Factory installed AGA/ASME rated

T&P relief valve• Handhole cleanout• 180° max operating temperature

• Certified for a 150 PSI maximumworking pressure (160 PSI for ASMEmodels)

• Manual reset high limit (ASME models)

• Low NOx Burner – The Power Assistenclosed burner design incorporatesstainless steel multi-port burner tubes for long term Low NOx compli-ant performance. A sight glass allowsfor burner observation and the entire assembly is easily removable. A blower guard is provided againstpost-installation damage. The entiredesign is highly resistant to the effects of negative air pressurescommon to modern commercialbuildings.

WATER CONNECTIONS APPROXIMATE

MODEL TOP FRONT REAR SHIPPING WEIGHT

NUMBER A B C D E F G H IN/OUT SIDE SIDE STD. ASME GN75-125 65-1/2 61 26-1/4 25 5 56 3/4 20 1-1/2 1-1/2 1-1/2 480 lbs. N/A GN82-156 68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 490 lbs. N/A GN37-200 49-1/4 43-3/8 26-1/4 25 6 37-5/8 3/4 20 1-1/2 1-1/2 1-1/2 405 lbs. N/A GN76-200 68-13/16 64 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 540 lbs. N/A GN91-200 76-5/16 71-13/16 26-1/4 30-5/8 6 66-3/8 3/4 20 1-1/2 1-1/2 1-1/2 600 lbs. N/A GN100-200(A) 73-1/16 66-1/8 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 780 lbs. 835 lbs. GN72-250(A) 71-1/16 64-1/2 26-1/4 25 6 58-5/8 3/4 20 1-1/2 1-1/2 1-1/2 590 lbs. 630 lbs. GN100-250(A) 73-1/4 66-1/8 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 795 lbs. 835 lbs. GN100-270(A) 73-7/8 66-1/8 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 805 lbs. 845 lbs. GN65-360(A) 70-11/16 64-1/2 26-1/4 25 8 58-5/8 3/4 N/A N/A 1-1/2 1-1/2 640 lbs. 680 lbs. GN100-400(A) 76 68-1/2 30-1/4 32-1/4 8 61-3/4 1 23 1-1/2 2 2 770 lbs. 810 lbs.

DIMENSIONS (Inches)

All Models Require a 120V /1.5 Amp Power Source. (A) Suffix Indicates ASME Tank Construction Available.

9

Page 7: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

10

E

C

G

F

D

B A

OUTLET

FRONT SIDE

INLET

FRONT SIDE

SYSTEM

SENTINEL

T&P

Xtreme Features:

• Small jacket diameters• Short floor-to-vent heights• Multiple water connections• System Sentinel™ LED diagnostic

system

Standard Features:

• 3 year limited tank warranty• Patented multiflue design• Low profile automatic flue damper• Specialized burner assembly• Spark-to-pilot ignition system• Full port, full flow brass

drain valve

• Factory installed AGA/ASME ratedT&P relief valve

• Handhole cleanout• Round premix stainless steel

burners• Manual reset high limit• Certified for a 150 PSI maximum

working pressure (160 PSI forASME models)

• Low NOx models:GX90-550(A)GX90-640(A)

® US LISTEDC

Xtreme™ High-Input Gas 550,000 – 715,000 BTU/HR.

11

MODEL INPUT BTU/HR. THERMAL NUMBER NATURAL & L.P. EFFICIENCY 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F GX90-550(A) 550,000 NAT 80% 1333 1067 889 762 667 593 533 485 444 410 381 GX90-640(A) 640,000 NAT 80% 1551 1241 1034 887 776 690 621 564 517 477 443 GX90-715(A) 715,000 NAT 80% 1733 1387 1156 991 867 770 693 630 578 533 495 GX90-500(A) LP 500,000 LP 80% 1212 970 808 693 606 539 485 441 404 373 346 GX90-600(A) LP 600,000 LP 80% 1455 1164 970 831 727 647 582 529 485 448 416 GX90-680(A) LP 680,000 LP 80% 1649 1319 1099 942 824 733 659 599 550 507 471 Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures, and exceedthe thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model.

RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises.

WATER CONNECTIONS APPROXIMATE

MODEL FRONT REAR SHIPPING WEIGHT

NUMBER A B C D E F G SIDE SIDE STD. ASMEGX90-550(A) 74.5 68 30 25 10 59 1 2 2 905 945GX90-640(A) 74.5 68 30 25 10 59 1 2 2 905 945GX90-715(A) 74.5 68 30 25 10 59 1 2 2 905 945GX90-500(A) LP 74.5 68 30 25 10 59 1 2 2 905 945GX90-600(A) LP 74.5 68 30 25 10 59 1 2 2 905 945GX90-680(A) LP 74.5 68 30 25 10 59 1 2 2 905 945All Models Require a 120V Power Source. (A) Suffix Indicates ASME Tank Construction Available.

DIMENSIONAL INFORMATION (All dimensions shown in inches)

Page 8: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

12

C

E

AB F

D

Standard Features:

• Non-condensing design• Integral automatic blower• Patented multi-flue tank design• Spark-to-pilot ignition system• System Sentinel™ LED diagnostic

system• Full port, full flow brass drain valve• No masonry or metal vent

chimney required• Installs with 3" or 4" schedule

40 PVC pipe• Vents up to 50 feet

VentMaster™ Power Direct Vent Gas 150,000 – 250,000 BTU/HR.

13

MODEL INPUT GPH

NUMBER BTU/HR. 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F GP100-150 150,000 364 291 242 208 182 161 146 132 122 112 104 GP100-200 199,900 485 388 323 277 242 215 194 176 162 149 138 GP100-250(A) 250,000 606 485 404 346 303 269 242 220 202 186 173

RECOVERY CAPACITIES (80% thermal efficiency) CLEARANCE TO COMBUSTIBLES (inches)

MODEL NUMBER SIDE REAR TOP GP100-150 2" 6" 18" GP100-200 51mm 153mm 459mm GP100-250(A)

TEMP. RISE AT 100°F IN GALLONS Minutes MODEL TANk CAP. INPUT 5 10 15 20 30 45 60 to Rec. NUMBER GALLONS BTU/HR. Minutes Minutes Minutes Minutes Minutes Minutes Minutes Contents GP100-150 100 150,000 82 94 106 119 143 179 216 40 GP100-200 100 199,900 86 102 118 135 167 215 264 31 GP100-250(A) 100 250,000 90 110 131 151 191 252 312 25

FIRST TIME DELIVERY (Includes useable storage and recovery for indicated times.)

WATER CONNECTIONS APPROXIMATE MODEL FRONT REAR SHIPPING NUMBER A B C D E F G IN/OUT SIDE WEIGHT

GP100-150 81-3/4 68-1/4 30-1/4 24-3/4 3 59 3/4 2 2 860 lbs. GP100-200 81-3/4 68-1/4 30-1/4 24-3/4 3 59 3/4 2 2 860 lbs. GP100-250(A) 81-3/4 68-1/4 30-1/4 24-3/4 4 59 3/4 2 2 860 lbs.

DIMENSIONS (Inches)

Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures, and exceed the thermal efficiency andstandby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model.

Page 9: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

Induced Draft Gas 250,000 – 360,000 BTU/HR.

14

C

H

E

ABF

D

OUTLET TOP

INLET TOP

OUTLET FRONT SIDE

OUTLET REAR SIDE

SYSTEM SENTINEL

T&P

INLET FRONT SIDE

INLET REAR SIDE

G

7" (178mm)

(On SelectedModels)

(With OptionalLeg Kit)

Universal Features:

• Small jacket diameters• Short floor-to-vent heights• Multiple water connections• System Sentinel™ LED

diagnostic system

Standard Features:

• 3 year limited tank warranty• Patented multiflue design• Factory installed draft inducer –

provides an induced draft allowing higher BTU's to bevented through a 6" vent

• 6" Category I appliance – allows for easy upgrade orretrofit of existing applications

• Spark-to-pilot ignition system

• Full port, full flow brass drain valve

15

MODEL INPUT BTU/HR. THERMAL NUMBER NATURAL & L.P. EFFICIENCY UNITS 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F GD100-250(A) 250,000 80% GPH 606 485 404 346 303 269 242 220 202 186 173 GD100-270(A) 270,000 80% GPH 655 524 436 374 327 291 262 238 218 201 187 GD100-310(A) 310,000 80% GPH 752 601 501 429 376 334 301 273 251 231 215 GD100-360(A) 360,000 80% GPH 873 698 582 499 436 388 349 317 291 269 249

Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z21.10.3 test procedures, and exceedthe thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states.(A) indicates available ASME model.

RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises.

WATER CONNECTIONS APPROXIMATE MODEL TOP FRONT REAR SHIPPING WEIGHT NUMBER UNITS A B C D E F G H IN/OUT SIDE SIDE STD. ASME GD100-250(A) inches 73-1/2 66-3/4 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 795 lbs. 835 lbs. GD100-270(A) inches 73-1/2 66-3/4 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 795 lbs. 835 lbs. GD100-310(A) inches 73-1/2 66-3/4 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 795 lbs. 835 lbs. GD100-360(A) inches 73-1/2 66-3/4 30-1/4 23-1/4 6 57-1/2 3/4 23 1-1/2 2 2 795 lbs. 835 lbs.

All models require a 120V /3 amp power source. (A) suffix indicates ASME tank construction available.

DIMENSIONAL INFORMATION All Dimensions Shown in English.

Page 10: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

16

Standard Features:

• Small jacket diameters• Short floor-to-vent heights• 3 year limited tank warranty• Rigid foam insulation• Heavy duty anode rod• Factory installed AGA/ASME rated

T&P relief valve• Brass drain valve• Gas control system• Certified for a 150 PSI maximum

working pressure• Low NOx models available – N Models

(with optional leg kit)

Medium-Duty Gas 45,000 – 80,000 BTU/HR.

AB

HOT & COLD

T & P

C

F

E

D 2"

3/4"

G1/2" GASCONNECTION

G100-80

WATER CONNECTIONS ARE 1" NPT

E

GBA

C

F

D

1/2"

3/4" N.P.T.RELIEFVALVE

OPENING

SIDE TAPS

G50-65, G60-50 & G75-75

SIDE TAPS ON 50 & 75 GAL. MODELS ONLY

G50-65 & G60-50 WATER CONNECTIONSARE 3/4" NPT

G75-75 WATER CONNECTIONSARE 1" NPT

17

CLEARANCES TOCOMBUSTIBLES MODEL REAR/NUMBER SIDES FRONT TOP

G60-50 1" 3" 2"

G50-65 0" 3" 2"

G75-75 1" 3" 2"

G100-80 1" Alcove 12"

NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITH FVIR MODELS

RECOVERY CAPACITIES MODEL CAP. INPUT GAS TEMPERATURE RISE – DEGREES F – GALLONS PER HOUR NUMBER GALS. BTU/HR. TYPE 40° 50° 60° 70° 80° 90° 100° 110° 120° 130°

G60-50N†* 60 Natural 50,000 115 92 77 66 58 51 46 42 38 35

G60-50LP* 60 LP 45,000 104 83 69 59 52 46 41 38 35 32

G50-65N†* 48 Natural 65,000 150 120 100 86 75 67 60 54 50 46

G50-65LP* 48 LP 48,000 111 88 74 63 55 49 44 40 37 34

G75-75N-2†* 75 Natural 75,100 182 146 121 104 91 91 73 66 61 56

G75-75LP* 75 LP 65,000 150 120 100 86 75 67 60 54 50 46

G100-80 100 Natural 80,000 194 155 129 111 97 86 78 71 65 60

G100-80N† 100 Natural 76,000 184 147 123 105 92 82 74 67 61 57

Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. N = Low NOx

DIMENSIONAL INFORMATION (All dimensions shown in inches)

MODEL APPROX. SHIPPING NUMBER A B C D E F G WEIGHT (LBS.)

G60-50 62 58 23 13-1/4 4 8 48-1/2 180

G50-65 62-1/2 58-1/2 21-3/4 14 4 11 51-3/4 180

G75-75 64 60 26-1/4 13-1/4 4 11 53-1/4 320

G100-80 69-5/8 65-3/4 28-1/4 11 4 15 57-13/16 410† Note: Meets 40ng/J Low NOx requirements.*FVIR compliant

Page 11: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

18

HOTWATER

CONNECTIONCOLD

WATERCONNECTION

POWER VENTASSEMBLY

C

B FA

D

GG

E

T&P FITTING3/4" N.P.T.

SIDE TAPS

1/2"

ANODE ROD

Standard Features:

• Uses 3" or 4" schedule 40 PVC, CPVC or ABS pipe• Vents up to 95 feet• Easy to install/maintain blower assembly• Spark-to-pilot ignition system• Low NOx burner• Self-diagnostic thermostat/gas valve• 2" rigid foam insulation• 3 year limited warranty• Factory installed AGA/ASME rated T&P relief valve• Certified for a 150 PSI maximum working pressure• Durable brass drain valve• FVIR compliant

PowerVent Gas 75,000 BTU/HR.

19

DIMENSIONAL INFORMATION (All dimensions shown in inches)

MODEL APPROX. SHIPPING NUMBER A B C D E F G WEIGHT (LBS.)

GPV75-75FV-2 72 60-1/8 26-1/4 14-3/4 11 53-1/4 1 330

RECOVERY CAPACITIES

MODEL INPUT BTU/HR. TEMPERATURE RISE - DEGREES F - GALLONS PER HOUR

NUMBER NATURAL & L.P. 40° 50° 60° 70° 80° 90° 100° 110° 120°

GPV75-75FV-2 75,000 173 138 115 99 86 77 69 63 58

GPV75-75PFV-2 70,000 161 129 107 92 81 72 64 59 54

Page 12: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

20

Construction Features:

• Certified for use on natural and propane gasmodels.

• Maximum venting length up to 50 feet equivalent including the vent terminal.

• Vent terminal can be installed through combustibleor non-combustible surfaces – heat shield is provided.

• Vent terminal is constructed from heavy-duty corrosion resistant aluminum.

• Venter can be connected to a vent termination on anexterior wall.

• Vibration isolators are supplied to provide quiet operation.

• Safety interlocks standard.• Complete with mounting hardware.• Venter is pre-wired with 40 feet of #18-4 copper wire

(24 volt) to minimize field connections.

Manufactured by Tjernlund Products, Inc., Rheem-Ruud Commercial Gas Water Heater PowerVent Kits are your best choice for new construction,electric-to-gas conversions and renovations.

For technical assistance, please call the Tjernlund Help Line at 1-800-255-4208.

Floor

Exterior Wall

F

TYPICAL APPLICATION

Power Vent kits Gas

21

Draft Vent Part Hood Vent Vent Model kit No. Outlet Size Adapter*

G50-98 PV Kit 4 AP11646 5" 4" 5" x 4"

G75-125 PV Kit 4 AP11646 5" 4" 5" x 4"

G82-156 PV Kit 4 AP11646 6" 4" 6" x 4"

G76-180 PV Kit 4 AP11646 6" 4" 6" x 4"

G37-200 PV Kit 5 AP11646 6" 4" Not Req.

G76-200 PV Kit 5 AP11645 6" 6" Not Req.

G91-200 PV Kit 5 AP11645 6" 6" Not Req.

G100-200(A) PV Kit 5 AP11645 6" 6" Not Req.

G72-250(A) PV Kit 5 AP11645 6" 6" Not Req.

G100-250(A) PV Kit 5 AP11645 8" 6" 8" x 6"

G100-270(A) PV Kit 5 AP11645 8" 6" 8" x 6"

G72-300(A) PV Kit 5 AP11645 8" 6" 8" x 6"

G85-300(A) PV Kit 5 AP11645 8" 6" 8" x 6"

G100-310(A) PV Kit 5 AP11645 7" 6" 7" x 6"

G65-360(A) PV Kit 5 AP11645 8" 6" 8" x 6"

G65-400(A) PV Kit 5 AP11645 8" 6" 8" x 6"

G85-400(A) PV Kit 5 AP11645 10" 6" 10" x 6"

G100-400(A) PV Kit 5 AP11645 8" 6" 8" x 6"

GD100-250(A) PV Kit 5 AP11645 6" 6" Not Req.

GD100-270(A) PV Kit 5 AP11645 6" 6" Not Req.

GD100-310(A) PV Kit 5 AP11645 6" 6" Not Req.

GD100-360(A) PV Kit 5 AP11645 6" 6" Not Req.

*Note: Vent Pipe and Vent Adapter are NOT included.

POWER VENTER (from Tjernlund)

Motor Motor Max Height Width Depth Inletkit# Watts Amps Vent (H) (W) (D) Outlet

4 95 1.26 50 ft 7-7/8" 11" 7" 4"

5 170 1.51 50 ft 9-1/4" 11-5/8" 8-5/8" 6"

Note: Max Vent Length based on total length of straight vent pipe plus 10feet for each 90 degree elbow and 5 feet for each 45 degree elbow.

H

D W

Power vent kits manufactured by Tjernlund Products, Inc. are tested and certified by CSA for use on these Rheem-Ruud Commercial Gas Heaters.• Not for use with GN, GP, and GX models.

VENT TERMINAL Rough in kit# A B C Dimension

4 9" 9-1/2" 7" Sq. 8" Sq.

5 10-1/8" 9-1/2" 8-1/2" Dia. 9" Dia.

A Sq. C

B

Page 13: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

22

Standard Features:

• 82% thermal efficiency• 5 year limited warranty• Indoor and outdoor installations• Meets ASHRAE standards• Natural gas or L.P.• Certified for a 160 PSI maximum

working pressure

Heat Exchanger:

• Finned copper tubes• ASME steel tubesheet• Silicon O-rings• 125 PSIG ASME pressure relief

valve• Glasslined cast iron headers

Controls:

• Energy saving pump control• Flow switch• Spark-to-pilot ignition system• High limit control• On/Off switch• Flue gas spillage sensor• Flame roll-out sensor

Gas Control Train:

• Manual gas shut-off cock• Main gas pressure regulator• Safety shut-off valve, redundant• Control valve

Hot Water Supply Heaters Gas 136,000 – 1,826,000 BTU/HR.

23

MBTUH PROPANE GAS†

Model Size Multiplier

136-399 Same as natural gas

512-825 .94

926-1826 .92 Indoor

.955 Outdoor (input)

.92 Outdoor (output)

†Multiplier x Nat. MBTUH = Pro. MBTUH

ELECTRICAL RATINGS

Model Size With Pump

136-399 3.7 amps @ 120V (1/8 hp pump)

331-399 3.6 amps @ 120V (1/6 hp pump)

512-1826 7.2 amps @ 120V (1/2 hp pump)

††Subtract 55 lbs. when ordering GBC models.

* Equipped with bronze headers, all other modelshave glasslined cast iron headers.GBC – cast iron headers.GBB – bronze headers.

Add “N“ after model number for Low NOx configuration on 186-399 models.

SPECIFICATIONS AND DIMENSIONS MODEL NUMBER STYLE MBTUH NATURAL GAS (X 1000) DIMENSIONS (INCHES) SHIPPING WEIGHT††

With- Temperature Rise – out With In- Out- (indoor) (outdoor) Gallons Per Hour Height Jac. Gas FluePump Pump door door Input Output Input Output 40°F 100°F 140°F Width Overall Ht. Conn. Dia. (Indoor) (Outdoor)

GBB136* GBBP136* • • 136.0 112.0 136.0 112.0 330 132 94 141⁄4 45.0 301⁄8 1⁄2 6 195 195

GBC186 GBCP186 • • 181.0 148.0 181.0 148.0 445 178 127 181⁄4 40.0 38 3⁄4 6 191 200

GBC264 GBCP264 • • 264.0 216.0 264.0 216.0 640 256 183 223⁄8 40.0 38 3⁄4 7 214 220

GBC331 GBCP331 • • 334.0 274.0 334.0 274.0 822 328 235 253⁄4 40.0 38 3⁄4 8 234 240

GBC399 GBCP399 • • 399.0 327.0 399.0 327.0 967 387 276 291⁄4 40.0 38 3⁄4 9 253 260

GBC512 GBCP512 • • 511.5 419.4 511.5 419.4 1240 496 354 323⁄4 57.0 33 1 10 510 535

GBC627 GBCP627 • • 627.0 514.1 627.0 514.1 1520 608 434 371⁄2 57.0 33 1 12 520 545

GBC726 GBCP726 • • 726.0 595.4 726.0 595.4 1760 704 503 415⁄8 57.0 33 1 12 630 685

GBC825 GBCP825 • • 825.0 676.5 825.0 676.5 2000 800 571 453⁄4 57.0 33 1 14 660 720

GBC926 GBCP926 – • – – 926.0 759.3 3345 898 641 523⁄8 – – 1 – – 790

GBC962 GBCP962 • – 961.7 788.6 – – 2331 933 665 523⁄8 683⁄4 331⁄2 1 14 760 –

GBC1083 GBCP1083 – • – – 1083.0 888.1 2625 1050 750 591⁄4 – – 1 – – 850

GBC1125 GBCP1125 • – 1124.7 922.2 – – 2727 1091 779 591⁄4 741⁄2 331⁄2 1 16 800 –

GBC1178 GBCP1178 – • – – 1178.0 966.0 2856 1142 816 635⁄8 – – 1 – – 910

GBC1223 GBCP1223 • – 1222.5 1002.4 – – 2964 1185 847 635⁄8 741⁄2 331⁄2 1 16 860 –

GBC1287 GBCP1287 – • – – 1287.0 1055.3 3120 1248 891 685⁄8 – – 11⁄4 – – 975

GBC1337 GBCP1337 • – 1336.6 1096.0 – – 3240 1296 926 685⁄8 761⁄2 331⁄2 11⁄4 18 930 –

GBC1413 GBCP1413 – • – – 1413.0 1158.7 3425 1370 979 747⁄8 – – 11⁄4 – – 1065

GBC1467 GBCP1467 • – 1467.0 1202.9 – – 3556 1423 1016 747⁄8 761⁄2 331⁄2 11⁄4 18 1000 –

GBC1570 GBCP1570 – • – – 1570.0 1287.4 3806 1522 1087 811⁄8 – – 11⁄4 – – 1120

GBC1630 GBCP1630 • – 1630.0 1336.5 – – 3952 1581 1129 811⁄8 791⁄2 361⁄2 11⁄4 18 1040 –

GBC1758 GBCP1758 – • – – 1758.0 1441.6 4262 1705 1218 893⁄8 – – 11⁄4 – – 1150

GBC1826 GBCP1826 • – 1825.6 1496.9 – – 4426 1770 1264 893⁄8 811⁄2 361⁄2 11⁄4 20 1090 –

Page 14: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

24

150 to 2,500 Gallon StorageRheem-Ruud large volume electric high power commercial water heaters are now available in 150 to 2,500 gallon storage – vertical round, verticalsquare and horizontal – with energy saving performance!

Construction Features:• Glass lined steel tank• Incoloy heating elements• Internal fusing (above 120 amps)• Magnesium anodes• Immersion thermostat• Manual reset high limit• ASME temperature and pressure relief valve• Channel iron skid base (except 150 & 200 gallon

round models)• 180° F temperature operation• 125 PSI working pressure• Handhole cleanout• 3 Year limited tank warranty

Optional Features:• Low water cut-off• Pilot lights• Manual limiting switches• Alarm bell• Shunt trip disconnect (Field installed)• Low or high water pressure switch• Lifting lugs• Time clock (7 day or 24 hour)• Safety door interlock• Temperature and pressure gauges• Manway (250 gallon and larger only)• 150 psi or 160 psi working pressure• Electronic step controller• Seismic attachment point (250 gallon and larger –

specify city, state and seismic zone)

Certification and Ratings:• Efficiency – All models meet or exceed ASHRAE

energy efficiency standards.• Safety and construction –

ASME construction and National Board listed UL1453 listed

Large Volume High-Power Electric 12 KW – 900 KW

208, 240, 277,380, 415, 480 and 600 VoltagesVertical Round,Vertical Square and Horizontal

High Power Energy Saving Performance

MODEL MAX. GALLON HEIGHT TO WATER CONNECTION APPROX. SHIP. NUMBER KW CAPACITY HEIGHT WIDTH DEPTH COLD INLET INLET OUTLET WEIGHTVERTICAL ROUND EVRO150 144 150 65-1/2 32 38-3/4 7-3/4 1-1/2 1-1/2 650 lbs. EVRO200 162 200 78 32 38-3/4 7-3/4 1-1/2 1-1/2 750 lbs. EVRO250 162 250 92 34 40-3/4 19-1/2 1-1/2 1-1/2 1,165 lbs. EVRO300 162 300 80 40 46-3/4 21 2 2 1,350 lbs. EVRO400 162 400 80 46 52-3/4 22-1/2 2 2 1,590 lbs. EVRO500 396 500 92 46 52-3/4 22-1/2 2 2 1,700 lbs. EVRO600 396 600 92 52 60-3/4 24-1/2 2-1/2 2-1/2 2,010 lbs. EVRO800 396 750 104 52 60-3/4 24-1/2 2-1/2 2-1/2 2,450 lbs. EVRO1000 396 950 128 52 60-3/4 24-1/2 2-1/2 2-1/2 3,160 lbs.VERTICAL SQUARE EVS1250 900 1,250 132-1/2 64-1/2 64-1/2 23-1/4 3 3 3,560 lbs. EVS1500 900 1,500 128-1/2 70-1/2 70-1/2 25-1/4 3 3 4,120 lbs. EVS2000 900 2,000 140-1/2 76-1/2 76-1/2 27-1/4" 3 3 4,350 lbs. EVS2500 900 2,500 146-1/2 82-1/2 82-1/2 29 3 3 5,750 lbs.HORIZONTAL EHS0150 144 150 37 68-1/2 34-1/4 12 2 2 1,180 lbs. EHS0200 180 200 37 78 34-1/4 12 2 2 1,370 lbs. EHS0250 225 250 39 90-1/4 36-1/4 13 2 2 1,450 lbs. EHS0300 270 300 45 78-1/4 42-1/4 14-3/4 2 2 1,530 lbs. EHS0400 360 400 52 78-1/4 48-1/4 16 2 2 1,750 lbs. EHS0500 450 500 52 90-3/4 48-1/4 16 2 2 1,860 lbs. EHS0600 540 600 58 90-3/4 54-1/4 13-1/2 2-1/2 2 2,340 lbs. EHS0800 720 750 58 102-1/4 54-1/4 13-/12 2-1/2 2 2,850 lbs. EHS1000 900 1,000 58 126-1/4 54-1/4 13-1/2 2-1/2 2 3,040 lbs. EHS1250 900 1,250 64 130-1/4 60-1/4 15 3 3 3,750 lbs. EHS1500 900 1,500 70 126-1/4 66-1/4 16 3 3 4,340 lbs. EHS2000 900 2,000 76 137-1/4 72-1/4 17-1/2 3 3 4,580 lbs. EHS2500 900 2,500 82 144-1/4 78-1/4 16-1/2 3 3 6,060 lbs.

Dimensional Information• Vertical round models above 90 KW at208V, 240V, or 380V and 162 KW at415V, 480V or 600V exceed thecapacity of a single control box andmay require mulitple control panels.Consult the factory for specific detailsand optional construction.

• Vertical square construction isavailable as an option for models thatexceed the listed KW limits.

• Control panel heights on vertical roundmodels may exceed tank height –consult factory for specific heights onmodels with inputs above 72 KW.

25

Page 15: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

26

Standard Features:

• System Sentinel™ L.E.D. diagnostic system

• Surface mounted and immersion thermostat modelsavailable

• Lifeguard stainless steel elements

• 208, 240, 277 and 480 voltages• 3 year limited tank warranty• Manual reset high limit control• Magnetic contactors and

integral fusing• 1-1/2" NPT inlet/outlet dielectric

nipples factory installed• 3" Rigid foam insulation

• Heavy duty anode rods• Full port, full flow, brass drain

valve• Factory installed AGA/ASME

rated T&P relief valve• Certified for a 150 PSI

maximum working pressure(160 PSI for ASME models)

Options:

• UL Sanitation compliant modelsavailable

• Thermostat staging• ASME construction available on

E models

B

C

D

A

361/8"

5"

SYSTEM SENTINEL

AUTOMATIC TEMPERATURE CONTROL (IMMERSION ONLY)

11/2" COLD INLET NIPPLE

11/2" HOT OUTLET NIPPLE

(With OptionalSeal Kit)

Heavy-Duty Electric 6 KW – 81 KW

DIMENSIONAL INFORMATION(All dimensions shown in inches)

MODEL APPROX. SHIPPING

NUMBER A B C D WEIGHT (LBS.) STD. ASME*

E(S)50 43-5/8 26-1/4 32 17-1/4 270 320

E(S)85 57-11/16 28-1/4 34 18-1/4 350 380

E(2)120 67-5/8 30-1/4 36 19-1/4 430 460

*ASME construction available only on Immersion Thermostat Models. All models are North Carolina Code compliant.27

WATER TEMPERATURE RATINGS Minimum Maximum HighModel Thermostat Delivered Delivered TemperatureNumber Type Temperature Temperature Limit

ES50 Surface 90°F 160°F 180°F

ES85, ES120 Surface 120°F 160°F 190°F

E50, E85, E120 Immersion 90°F 190°F 200°F

MODEL NUMBERS SURFACE MOUNTED THERMOSTATS IMMERSION THERMOSTATS

Tank Capacity In Gallons Tank Capacity In Gallons

50 85 120 50 85 120

ES50-6-G ES85-6-G ES120-6-G E50-6-G E85-6-G E120-6-G

ES50-9-G ES85-9-G ES120-9-G E50-9-G E85-9-G E120-9-G

ES50-12-G ES85-12-G ES120-12-G E50-12-G E85-12-G E120-12-G

ES50-15-G ES85-15-G ES120-15-G E50-15-G E85-15-G E120-15-G

ES50-18-G ES85-18-G ES120-18-G E50-18-G E85-18-G E120-18-G

ES50-24-G ES85-24-G ES120-24-G E50-24-G E85-24-G E120-24-G

ES50-27-G ES85-27-G ES120-27-G E50-27-G E85-27-G E120-27-G

ES50-30-G ES85-30-G ES120-30-G E50-30-G E85-30-G E120-30-G

ES50-36-G ES85-36-G ES120-36-G E50-36-G E85-36-G E120-36-G

ES50-45-G ES85-45-G ES120-45-G E50-45-G E85-45-G E120-45-G

ES50-54-G ES85-54-G ES120-54-G E50-54-G E85-54-G E120-54-G

N/A N/A N/A N/A E85A-81-GS E120A-81-GS

RECOVERY CAPACITIES INPUT EQUIVALENT TEMPERATURE RISE – DEGREES F – GPH kW BTU/HR. 40° 60° 80° 100° 120° 140°

6 20,473 62 41 31 25 21 18

9 30,709 92 61 46 37 31 26

12 40,946 123 82 61 49 41 35

15 51,182 154 102 77 61 51 44

18 61,418 184 123 92 74 61 53

24 81,891 246 164 123 98 82 70

27 92,128 276 184 138 111 92 79

30 102,364 307 205 154 123 102 88

36 122,837 369 246 184 147 123 105

45 153,546 461 307 230 184 154 132

54 184,256 553 369 276 221 184 158

81 276,388 838 558 419 335 279 239

In accordance with ANSI testprocedures, these modelstested below the maximum al-lowable standby loss levels ofASHRAE (Part of the Federallymandated Energy Policy Act(EPact)). Also exceeds energycodes of all states includingCalifornia Energy Commission(CEC).

Page 16: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

28

Standard Features:

• System Sentinel™ L.E.D. diagnostic system

• Immersion thermostat • Lifeguard stainless steel

elements• 208, 240, 277 and 480

voltages• 3 year limited tank

warranty• Manual reset high limit

control• Magnetic contactors and

integral fusing• 3/4" couplings• 2-1/2" Rigid foam

insulation

• Heavy duty anode rods• Brass drain valve• Factory installed

AGA/ASME rated T&Prelief valve

• Certified for a 160 PSI maximum working pressure

• All models ASME certified

Options:

• UL Sanitation compliantring seal kits available

B8"

D

A

E

3/4" T&P

41/4" 21/2"

SYSTEM SENTINEL

AUTOMATIC TEMPERATURE CONTROL

C

(With OptionalSeal Kit)

PowerPack™ Small Volume ASME Electric 3 KW – 36 KW

29

MODEL NUMBERS IMMERSION THERMOSTATS Tank Capacity In Gallons

12 20 30 40

E12A-3-G E20A-3-G E30A-3-G E40A-3-G

E12A-6-G E20A-6-G E30A-6-G E40A-6-G

E12A-9-G E20A-9-G E30A-9-G E40A-9-G

N/A E20A-12-G E30A-12-G E40A-12-G

N/A E20A-15-G E30A-15-G E40A-15-G

N/A E20A-18-G E30A-18-G E40A-18-G

N/A N/A E30A-24-G E40A-24-G

N/A N/A E30A-27-G E40A-27-G

N/A N/A E30A-30-G E40A-30-G

N/A N/A E30A-36-G E40A-36-G

INPUTkW

3

6

9

12

15

18

24

27

30

36

RECOVERY CAPACITIESRecovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises

INPUT EQUIVALENT 40°F 60°F 80°F 100°F 120°F 140°F kW BTU/HR. (22.2°C) (33.3°C) (44.4°C) (55.6°C) (66.7°C) (77.8°C)

3 10,236 31 21 16 12 10 9

6 20,473 62 41 31 25 21 18

9 30,709 93 62 47 37 31 27

12 40,946 124 83 62 50 41 35

15 51,183 155 103 78 62 52 44

18 61,420 186 124 93 74 62 53

24 81,893 248 165 124 99 83 71

27 92,129 279 186 140 112 93 80

30 102,366 310 207 155 124 103 89

36 122,839 372 248 186 149 124 106

WATER TEMPERATURE RATINGS Minimum Maximum High Model Tank Capacity Thermostat Delivered Delivered Temperature Number Gallons Type Temperature Temperature Limit

E12A 13 Immersion 90°F 190°F 200°F

E20A 19.9 Immersion 90°F 190°F 200°F

E30A 30 Immersion 90°F 190°F 200°F

E40A 40 Immersion 90°F 190°F 200°F

DIMENSIONAL INFORMATIONAll dimensions shown in inches

MODEL APPROX. SHIPPING

WEIGHT (LBS.) NUMBER A B C D E ASME

E12A 28-1/2 19 24-1/4 14-3/4 26-1/4 135

E20A 36-1/2 19 24-1/4 14-3/4 26-1/4 160

E30A 49-1/4 19 24-1/4 14-3/4 32-1/2 192

E40A 53-3/4 21 26-3/4 16-1/2 32-1/2 228

In accordance with ANSI testprocedures, these modelstested below the maximumallowable standby loss levelsof ASHRAE (Part of the Federally mandated EnergyPolicy Act (EPact)). Also exceeds energy codes of allstates including CaliforniaEnergy Commission (CEC).

All models are North Carolina and Massachusetts Code compliant.

Page 17: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

30

Standard Features:

• 85 and 105 gallon models• Inputs from 12, 18 and 24 KW• Staged element operation• 208, 240, 277 and 480 voltages, single or three phase• Plastic tank design – no anode rods• (4) Inconel heating elements• System Sentinel™ LED diagnostic system• Full port, full flow, brass drain valve• UL Sanitation listed• Less than half the weight of steel construction• Industry leading stand-by loss efficiencies

D

B C

A

EXCLUSIVE 10 YEAR LIMITED TANk WARRANTY!

Eclipse™ 10-Year Electric 12 KW – 24 KW

31

MODEL NUMBERSSURFACE MOUNTED THERMOSTATSTank Capacity In Gallons

85 105

ME85-12-G ME105-12-G

ME85-18-G ME105-18-G

ME85-24-G ME105-24-G

INPUTkW

12

18

24

RECOVERY CAPACITIESRecovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises

INPUT EQUIVALENT kW BTU/HR. 40°F 60°F 80°F 100°F 120°F

12 40,946 123 82 61 49 41

18 61,418 184 123 92 74 61

24 81,891 246 164 123 98 82

WATER TEMPERATURE RATINGS Minimum Maximum Tank Capacity Thermostat Delivered Delivered Gallons Type Temperature Temperature

85 Surface 90 160°

105 Surface 90 160°

DIMENSIONAL INFORMATIONAll dimensions shown in inches

MODEL APPROX. SHIPPING

WEIGHT (LBS.) NUMBER A B C D ASME

85 Gals 28-1/4 66-1/4 70-1/4 4-1/2 170

105 Gals. 30-1/4 66-1/2 70-3/4 4-1/2 185

In accordance with ANSI test procedures,these models tested below the maximumallowable standby loss levels of ASHRAE(Part of the Federally mandated EnergyPolicy Act (EPact)). Also exceeds energycodes of all states including California Energy Commission (CEC).

Page 18: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

32

Standard Features:• System Sentinel™

L.E.D. diagnostic system• Immersion thermostats• Manual reset high limit

control• 208, 240, 277 and 480

voltages• 3 year limited tank

warranty• Magnetic contactors and

integral fusing

• Heavy duty anode rods• Durable brass drain

valve• Factory installed

AGA/ASME rated T&Prelief valve

• 6" stainless steel legs• UL Sanitation compliant• Certified for a 150 PSI

max working pressure

Factory Accessories –

• Solid state low water cut-off

• Pressure reducing valvewith bypass

Booster Electric 6 KW – 54 KW

33

WATER TEMPERATURE RATINGS Minimum Maximum High Gallon Thermostat Delivered Delivered Temperature Capacity Type Temperature Temperature Limit

10 Immersion 90°F 190°F 200°F

These models meet the energy efficiency levels of ASHRAE (Part ofthe Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). All models areNorth Carolina Code compliant.

RECOVERY CAPACITIES MODEL INPUT EQUIVALENT TEMPERATURE RISE – DEGREES F – GPH

NUMBER kW BTU/HR. 40° 60° 80° 100° 120° 140°

E10-6-G 6 20,473 62 41 31 25 21 18

E10-9-G 9 30,709 92 61 46 37 31 26

E10-12-G 12 40,946 123 82 61 49 41 35

E10-15-G 15 51,182 154 102 77 61 51 44

E10-18-G 18 61,418 184 123 92 74 61 53

E10-24-G 24 81,891 246 164 123 98 82 70

E10-27-G 27 92,128 276 184 138 111 92 79

E10-30-G 30 102,364 307 205 154 123 102 88

E10-36-G 36 122,837 369 246 184 147 123 105

E10-45-G 45 153,546 461 307 230 184 154 132

E10-54-G 54 184,256 553 369 276 221 184 158

Approximate Weight – 110 Lbs.

3/4" T&P

213/4"

81/4"

43/4"

53/4"

6"

133/4"

17"

INLET

OUTLET

CONTACTORS

TRANSFORMER

TERMINAL BLOCK

FUSE BLOCKS (FUSED MODELS ONLY)

OPTIONAL THERMOSTATS (-GS MODELS ONLY)

THERMOSTAT

TEMPERATURE LIMIT CONTROL

ELEMENT AND CLEANOUT ACCESS PANEL

11/4" HOT OUTLET NIPPLE

11/4" COLD INLET

NIPPLE

211/2"

Page 19: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

34

Standard Features:

• 208, 240, 277, and 480 voltages• Porcelain enamel lined tank• Heavy duty anode rod• 2-1/2" of rigid foam insulation• Baked enamel steel jacket• Patented resistor heating elements• Surface mounted thermostat• Manual reset high limit control• 3 year limited warranty• Certified for a 150 PSI maximum working pressure• Factory installed AGA/ASME rated T&P relief valve• Durable brass drain valve ANODE

ROD

COLD WATER

CONNECTION

WATER CONNECTIONS ALL 3/4" NPT

3/4" T&P

HOT WATER

CONNECTION

8"

B DIA.

A

Light-Duty Electric 3 KW – 12 KW

35

ELECTRICAL CHARACTERISTICS AND CAPACITIES(Non-Simultaneous /Single or Three Phase Operation)

ELEMENT RECOVERY CAPACITIES GPH FULL LOAD CURRENT (AMPS) WATTAGE @ TEMPERATURE RISE OF (ALL TERMINALS) UPPER/LOWER 40° 60° 80° 100° 120° 208 240 277 480

3000/3000 31 20 15 12 10 14.4 12.5 10.8 6.3

4000/4000 41 27 20 16 13 19.2 16.7 14.4 8.3

4500/4500 46 31 23 18 15 21.6 18.8 16.2 9.4

5000/5000 51 34 26 20 17 24 20.8 18.1 10.4

6000/6000 61 41 31 25 20 28.8 25 21.7 12.5

ELECTRICAL CHARACTERISTICS AND CAPACITIES(Simultaneous /Three Phase Operation)

ELEMENT RECOVERY CAPACITIES GPH FULL LOAD CURRENT (AMPS) WATTAGE @ TEMPERATURE RISE OF (TERMINAL L3/TERMINALS L1 & L2)

UPPER/LOWER 40° 60° 80° 100° 120° 208 240 480

3000/3000 61 41 31 24 20 25/14.4 21.7/12.5 10.8/6.3

4000/4000 81 54 41 32 27 33.3/19.2 28.9/16.7 14.4/8.3

4500/4500 91 61 45 37 31 37.5/21.6 32.5/18.8 16.2/9.4

5000/5000 102 68 51 41 34 41.6/24 36.1/20.8 18/10.4

6000/6000 122 81 61 49 41 N/A 43.3/25.0 21.7/12.5

DIMENSIONAL INFORMATION (All dimensions shown in inches)

MODEL TANk CAPACITY APPROX. SHIPPING NUMBER GALLONS A B WEIGHT (LBS.)

ELDS30 30 29-1/2 22-1/4 105

ELDS40 38 31-1/2 23 135

ELDS52 47 32-1/2 26-1/4 150

ELD30 30 45-1/2 17-3/4 90

ELD40 40 46-1/4 22-1/4 108

ELD52 50 57 22-1/4 127

ELD66 65 58-3/4 23 170

ELD80 80 59 24-1/2 200

ELD120 120 62-1/2 28-1/4 330

WATER TEMPERATURE RATINGS: Thermostat Type: Surface Mounted Min. Delivered Temperature: 110° F Max. Delivered Temperature: 170° F High Temperature Limit: 190° F

These models have been tested according to DOE test procedures, and exceed the minimum energyfactor requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Alsoexceeds energy codes of all states including California Energy Commission (CEC). All modelsare North Carolina and Massachusetts Code compliant.

Page 20: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

36

Standard Features:

• 120, 208, 240, 277 and 480 voltages• Porcelain enamel lined tank• Heavy duty anode• Rigid foam insulation• Baked enamel steel jacket• Resistor heating element• Surface mounted thermostat• Manual reset high limit control• 3 year limited warranty• Certified for a 150 PSI maximum working pressure• Factory installed AGA/ASME rated T&P valve• Optional wall mounting kit

These models meet the minimum energy factor requirements of ASHRAE (Part of the Federally mandatedEnergy Policy Act (EPact)). Also exceeds energy codes ofall states including California Energy Commission (CEC). All models are North Carolina and Massachusetts Code compliant.

ELEMENT AVAILABILITY WATTAGE 120 V 208 V 240 V 277 V 480 V 1,440 **Y N/A N/A N/A N/A 1,500 Y Y **Y N/A N/A 2,000 Y Y Y Y Y 2,500 Y Y Y N/A N/A 3,000 Y Y Y Y Y 4,500 N/A Y *Y *Y *Y 6,000 N/A Y Y Y Y

*Not available in EGSP6 & EGSP10**EGSP2 available only in these configurations.

Point-of-Use Electric 1,440 – 6,000 WATTS

37

DIMENSIONAL INFORMATION (All dimensions shown in inches)*

MIN MAX TANk SHIPPING MODEL WATTS WATTS GALLONS A B C D E WEIGHT (LBS.)

EGSP2 1,440 1,500 2-1/2 14 9-3/4 — — — 18

EGSP6 1,500 6,000 6 15-1/8 15-3/4 12-5/8 11-5/8 4-1/4 41

EGSP10 1,500 6,000 10 22-7/8 15-3/4 20-3/8 19-3/8 4-1/4 53

EGSP15 1,500 6,000 15 24-1/4 17-3/4 21-7/8 19-3/8 4-5/8 65

EGSP20 1,500 6,000 19.9 25-1/8 19-3/4 22-5/8 19-5/8 5-1/8 76

EGSP30 1,500 6,000 30 30 21-3/4 23 23 2-3/4 115

Water Temperature Ratings:

Thermostat Type: Surface

Mounted

Min. Delivered Temperature: 110°F

Max. Delivered Temperature: 170°F

High Temperature Limit: 190°F

B DIA.

A

HOT WATER CONNECTION COLD WATER

CONNECTION

3/4" T&P

31/2"MODELS:EGSP6EGSP10EGSP15EGSP20EGSP30

Water Connections 3/4" NPT

MODEL: EGSP2Water Connections 1/2" NPT

AC

B

D

3/4" T&P

HOT WATER OUTLET

COLD WATER INLET

E

ELECTRICAL CHARACTERISTICS ELEMENT FULL LOAD CURRENT IN AMPERES

WATTAGE 120 V 208 V 240 V 277 V 480 V

1,440 12.0 N/A N/A N/A N/A 1,500 12.5 7.2 6.3 N/A N/A 2,000 16.7 9.6 8.3 7.2 4.2 2,500 20.8 12.0 10.4 N/A N/A 3,000 25.0 14.4 12.5 10.8 6.3 4,500 N/A 21.6 18.8 16.2 9.4 6,000 N/A 28.8 25.0 21.7 12.5 All models employ 1 heating element resulting in a 2-wire outlet (single phase) electrical configuration.

RECOVERY CAPACITIES TEMPERATURE RISE - DEGREES F - ELEMENT GALLONS PER HOUR

WATTAGE 40°F 60°F 80°F 100°F 120°F 140°F

1,440 15 10 7 6 5 4 1,500 15 10 8 6 5 4 2,000 20 14 10 8 7 6 2,500 25 17 13 10 8 – 3,000 30 20 15 12 10 9 4,500 46 30 23 18 15 13 6,000 61 41 30 24 20 17

Basic model numbers are listed. When ordering specify electrical input to determine specific model number:Basic Model: EGSP6 Specified Input: 6,000 Watts Specified Model Number: EGSP6-6Use CEGSP Prefix for Canadian Models.

Page 21: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

38

Construction Features:

• 30, 38, 45, 75 and 110 gallon models• Heavy gauge steel tank• High temperature porcelain enamel protect all tank and coil

• Factory installed automatic temperaturecontrols

• Factory installed brass drain valve• Temperature and pressure relief valve• 1-1/2" coil diameter• 2" Non-CFC foam insulation• Two heavy-duty magnesium anode rods• Factory installed dielectric nipples

Indirect Water Heaters

STID80 & STID120

STID30, STID40 & STID50

GHA

E

F

D

C

B

Cold Inlet, 1" NPT

Hot Outlet,1-1/2" NPT

Anode RodAnodeRod

T&P Relief Valve

From Boiler,1" NPT

To Boiler, 1"NPT

Drain ValveAquastat

G

Cold Inlet, 3/4" NPT

Hot Outlet/Anode Rod,3/4" NPT

Anode Rod

Aquastat

T&P Relief Valve

From Boiler, 1" NPT

To Boiler,1" NPT

Drain Valve

F

D

C

E

B

A

DIMENSIONAL INFORMATION MODEL APPROX. SHIPPING NUMBER UNITS A B C D E F G H WEIGHT

STID30 inches 22 35-3/4 27-3/4 18-1/2 11-3/4 6-1/2 4-1/2 N/A 180 lbs STID40 inches 22 42-3/4 34-3/4 31-1/2 16-3/4 6-1/2 4-1/2 N/A 226 lbs STID50 inches 22 48-3/4 39-3/4 31-1/2 16-3/4 6-1/2 4-1/2 N/A 231 lbs. STID80 inches 24 64-1/8 57-1/8 33 19-1/4 8 5 5 297 lbs. STID120 inches 28 65-1/4 57-3/4 33-3/4 16-1/4 8-3/4 5 6-1/2 397 lbs.

Note: First Hour Rating =First Dray + ContinuousDrawWarning: Installationshould be in accordancewith all national and/orlocal codes.In the absence of localcodes, refer to NFPA 54 or ANSI Z.21.10.1.Caution: The recom-mended maximum hotwater temperature settingfor normal residential useis 120°F. Rheem recom-mends a tempering valve or anti-scald valvebe installed and used ac-cording to the manufacturer’s directionsto prevent scalding.Pressures (all): Test pressure, 300 psi; workingpressure, 150 psiStandard Voltage (all):120V, 60 Hz, 1PT&P valve installedAll data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATERS TESTING STANDARD IWH-TS-1_MARCH 2003

*At 8 GPM **Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water.39

FIRST HOUR RATING (gal) @ Coil Output (Btu/hr) TANK FIRST HEAT SOURCE MODEL CAPACITY DRAW FRICTION LOSS* 180°F, 180°F, 180°F, 200°F, 200°F, 200°F, 200°F, NUMBER (GAL) (GAL) (FT. W.C.) 8 GPM** 10 GPM** 12 GPM** 8 GPM** 10 GPM** 12 GPM** 14 GPM**

STID30 30 25 2 115@56,000 117@57,000 118@58,000 138@71,000 144@75,000 149@78,000 154@81,000 STID40 38 33 3 173@89,000 183@96,000 191@101,000 214@115,000 226@123,000 235@129,000 243@134,000 STID50 45 40 3 180@89,000 190@96,000 198@101,000 221@115,000 233@123,000 242@129,000 250@134,000 STID80 75 70 5 233@104,000 245@111,000 254@117,000 277@132,000 292@141,000 304@149,000 314@155,000 STID120 110 102 5 265@104,000 277@111,000 286@117,000 309@132,000 324@141,000 336@149,000 346@155,000

Page 22: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

40

Standard Features:

• Porcelain enamel lined tank• Heavy duty anode rods• ASME construction available• 2" of rigid foam insulation• Baked enamel steel jacket• 5 year limited warranty

These models exceed the minimum efficiency requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact).

Storage Tanks 80 – 175 GAL.

41

HOT

HOT OUTLET OPENING

1" NPT T&P OPENING

3/4" NPT THERMOMETER OPENING

3/4" NPT AQUASTAT OPENING

CIRCULATING CONNECTIONS

D C

A

B

DIMENSIONAL INFORMATION (DIMENSIONS SHOWN IN INCHES)

WATER CONNECTIONS APPROX. MODEL TOP FRONT WEIGHT (LBS.) NUMBER A B C D OUTLET SIDES STANDARD ASME

ST80(A) 58-5/16 24-3/16 13-3/16 6-3/16 2 2 220 lbs. 260 lbs.

ST100(A) 46 32-1/4 12-9/16 5-9/16 – 2 475 lbs. 475 lbs.

ST120(A) 59-1/4 28-1/4 11-1/16 4-1/16 2 2 300 lbs. 340 lbs.

ST175(A) 67-1/4 32-1/4 12-9/16 5-9/16 2-1/2 2-1/2 600 lbs. 600 lbs.

TANk INFORMATION TANk MAXIMUM WORkINGMODEL CAPACITY PRESSURE

NUMBER (GALLONS) STD. ASME

ST80(A) 80 150 PSI 125 PSI

ST100(A) 100 150 PSI 160 PSI

ST120(A) 115 150 PSI 160 PSI

ST175(A) 175 150 PSI 150 PSI ST80(A), ST120(A), ST175(A)

3/4" NPTAQUASTATOPENING

3/4" NPT DRAIN OPENING

3/4" NPTTHERMOMETEROPENING

T&POPENING

2” OPENINGSFORCIRCULATINGLINES

DC

A

B

39-15/16

ST100(A)

Page 23: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

42

Standard Features:

• Available in jacketed and non-jacketed models

• 200, 260, 320, 430, 500, 750and 950 gallon capacities

• Porcelain enamel lined tank• Heavy duty anode rods• 2" of rigid foam insulation• Baked enamel steel jacket• 5 year limited warranty• All large volume commercialstorage tanks are certified toASME heater and pressurevessel code standards

TANk INFORMATION (Shown in English & Metric)

MAXIMUM WORkING MODEL TANk CAPACITY PRESSURE NUMBER GALLONS LITERS ASME ST(U)200A 200 758 150 PSI 1034 kPa

ST(U)260A 257 974 125 PSI 862 kPa

ST(U)320A 318 1205 125 PSI 862 kPa

ST(U)430A 432 1637 125 PSI 862 kPa

ST(U)500A 504 1910 125 PSI 862 kPa

ST(U)750A 752 2850 125 PSI 862 kPa

ST(U)950A 940 3563 125 PSI 862 kPa

1" DRAIN PIPE

CD

3/4" NPTAQUASTATOPENING

B

1" NPT RELIEF VALVE

OPENING(ST200A)

1-1/4" NPT T&P (ST260A AND ABOVE) 2" NPT

A

2"

4"

A

D

B

C

3/4"

Large Volume Storage Tanks 200 – 940 GAL.

43

DIMENSIONAL INFORMATION FOR VERTICAL ROUND JACkETED STORAGE TANkS(All dimensions shown in English and Metric)

WATER CONNECTIONS APPROX. MODEL TOP FRONT SHIPPING NUMBER UNITS A B C D OUTLET SIDE WEIGHT

ST200A inches 77-1/4 32 11-1/2 17-1/4 2 2-1/2 500 lbs. mm 1962 813 292 438 51 63.5 227 kgs.

ST260A inches 95-1/2 34 18 26 2 3 1108 lbs. mm 2426 864 457 660 51 76 503 kgs.

ST320A inches 84-1/2 40 19-3/4 27-1/4 2 3 1290 lbs. mm 2146 1016 502 692 51 76 586 kgs.

ST430A inches 84-1/2 46 21 29 2 3 1626 lbs. mm 2146 1168 533 737 51 76 738 kgs.

ST500A inches 94-1/2 46 21 29 2 3 1765 lbs. mm 2400 1168 533 737 51 76 801 kgs.

ST750A inches 107-1/2 54 22-7/8 30-7/8 2 3 2330 lbs. mm 2731 1372 581 784 51 76 1058 kgs.

ST950A inches 131-1/2 54 22-7/8 30-7/8 2 3 3010 lbs. mm 3340 1372 581 784 51 76 1367 kgs.

DIMENSIONAL INFORMATION FOR VERTICAL BARE (NON-JACkETED) STORAGE TANkS(All dimensions shown in English and Metric)

WATER CONNECTIONS APPROX. MODEL TOP FRONT SHIPPING NUMBER UNITS A B C D OUTLET SIDE WEIGHT

STU200A inches 75-3/4 28 14-5/8 18 2 3 488 lbs. mm 1924 711 371 157 51 76 222 kgs.

STU260A inches 88 30 15-3/4 23-3/4 2 3 464 lbs. mm 2235 762 400 603 51 76 211 kgs.

STU320A inches 76 36 17-3/8 25-3/8 2 3 574 lbs. mm 1930 914 441 645 51 76 261 kgs.

STU430A inches 76 42 18-7/8 26-7/8 2 3 816 lbs. mm 1930 1067 479 683 51 76 370 kgs.

STU500A inches 88 42 18-7/8 26-7/8 2 3 925 lbs. mm 2235 1067 479 683 51 76 420 kgs.

STU750A inches 100 48 20-7/8 28-7/8 2 3 1387 lbs. mm 2540 1219 530 733 51 76 630 kgs.

STU950A inches 124 48 20-7/8 28-7/8 2 3 1651 lbs. mm 3150 1219 530 733 51 76 750 kgs.

Jacketed models meet or exceed the minimum efficiency requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact).

Page 24: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

44

Competitors’ larger units mean a difficult installation. Universal’s heavy dutygas models are shorter and narrower for easy and convenient installation.

156,000 BTU 199,900 BTU 250,000 BTU 300,000 BTU 360,000 BTU 399,900 BTU

TroubleZone

Easy-to-

InstallZone

45

CertiSpec3.2

What’s new?32-bit upgrade! What does that mean? Well, nothing you can see or touch,

but this major enhancement is the engine that drives many of the new features.New Features:

• Internet Upgrades! No more “new” versions• Internet or mail-in registration (no mandatory registration either!)• Fuel Cost Calculator• User defined (imported) business logo/info on job spec document• Long File Name recognition• Most recent projects listed under File Menu• Multiple open projects• Direct CS3 to CS3 email attachment of project file

Additional Models:

• SPIDERfire sizing• Small Volume ASME cross reference• Low NOx sizing• Large Volume Storage Tank reference

Computer Requirements:

• Windows 95/98 or NT 4.X• Pentium 90 or higher required• 16 megabyte RAM (32 recommended)• Disk Space: 4-6 megabytes (estimated)• Internet connection required for email and Upgrade Download• 800 x 600 screen resolution

NOW INCLuDES SPIDERFIRE MODELS!

Page 25: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

46

A.O. SMITH RHEEM-RUUD

Model Btu/Hr. Gal Dia. Height Model Btu/Hr. Gal Dia. Height

Gas Tank Type Models BTR-120 120,000 71 27-3/4" 69-3/4" G75-125 125,000 75 26-1/4" 65-1/2" BTR-154 154,000 81 27-3/4" 73" G82-156 156,000 82 26-1/4" 68-13/16" BTR-180 180,000 81 27-3/4" 67-1/2" G76-180 180,000 76 26-1/4" 68-13/16" BTR-197 199,000 100 27-3/4" 74" G100-200 199,900 100 30-1/4" 73-1/16" BTR-198 199,000 100 27-3/4" 74" G100-200 199,900 100 30-1/4" 73-1/16" BTR-199 190,000 81 27-3/4" 67-1/2" G76-200 199,900 76 26-1/4" 68-13/16" BTR-200(A) 199,000 100 30-1/4" 72" G100-200(A) 199,900 100 30-1/4" 73-1/16" BTR-250(A) 250,000 100 30-1/4" 72" G100-250(A) 250,000 100 30-1/4" 73-1/4" BTR-251(A) 251,000 65 27-3/4" 75" G72-250(A) 250,000 72 26-1/4" 71-1/16" BTR-275(A) 275,000 100 30-1/4" 72" G100-270(A) 270,000 100 30-1/4" 73-7/8" BTR-305(A) 305,000 65 27-3/4" 75" G72-300(A) 300,000 72 26-1/4" 71" BTR-365(A) 365,000 85 27-3/4" 79-1/2" G65-360(A) 360,000 65 26-1/4" 70-11/16" BTR-400(A) 399,000 100 30-1/4" 75-1/2" G100-400(A) 399,900 100 30-1/4" 76" BTR-500(A) 500,000 85 27-3/4" 82-1/4" GX90-550(A) 550,000 90 30" 74-1/2"

A.O. SMITH TO RHEEM-RUUD CONVERSION CHART

47

Conservationist/Damper – Gas Tank Type Models BT-80 75,000 75 25-1/2" 61-1/8" G75-75 75,000 75 26-1/4" 64-3/8" BT-100 75,000 100 26-1/2" 68-3/4" G100-80 75,000 100 28-1/4" 69-5/8"

NOTE: (A) denotes ASME construction available.

Sealed Combustion Gas-Fired

BTH-120 125,000 60 27-3/4" 55-1/2" HE80-130 130,000 80 23-1/2" 72" BTH-150 150,000 100 27-3/4" 74-1/2" HE119-160 160,000 119 27" 73" BTH-199 199,000 100 27-3/4" 74-1/2" HE119-199 199,000 119 27" 73"

Induced Draft Models

BTI250(A) 250,000 100 27-3/4" 72" GD-100-250(A) 250,000 100 30-1/4" 73-1/2" BTI275(A) 275,000 100 27-3/4" 72" GD-100-270(A) 270,000 100 30-1/4" 73-1/2" BTI310(A) 310,000 85 27-3/4" 73" GD-100-310(A) 310,000 100 30-1/4" 73-1/2" BTI366(A) 366,000 85 27-3/4" 73" GD-100-360(A) 360,000 100 30-1/4" 73-1/2"

High Efficiency Models

BTH-150 150,000 100 27-3/4" 74-1/2" GHE100-160 160,000 100 26-1/4" 78-3/4" BTH-199 199,000 100 27-3/4" 74-1/2" GHE-100-200(A) 199,900 100 26-1/4" 78-3/4" BTH-150(A) 240,000 100 27-3/4" 74-1/2" GHE-100-250(A) 250,000 100 26-1/4" 78-3/4" BTH-300(A) 300,000 130 33" 74" GHE-100-300(A) 300,000 100 26-1/4" 78-3/4"

Page 26: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

48

A.O. SMITH RHEEM-RUUD

Model Btu/Hr. Gal Model Btu/Hr. Gal

Gas – Hot Water Supply Heaters HW-120 120,000 ** GBB/GBBP-136 136,000 ** HW-160 160,000 ** GBC/GBCP-186 181,000 ** HW-200 199,000 ** GBC/GBCP-186 181,000 ** HW-225 225,000 ** GBC/GBCP-264 264,000 ** HW-300 300,000 ** GBC/GBCP-331 334,000 ** HW-399 399,000 ** GBC/GBCP-399 399,000 ** HW-420 420,000 ** GBC/GBCP-399 399,000 ** HW-520 520,000 ** GX90-550 550,000 90 HW-670 670,000 ** GX90-640 640,000 90 HW-1240 1,240,000 ** GBC/GBCP-1223 1,222,500 ** HW-1340 1,340,000 ** GBC/GBCP-1337 1,336,600 ** DW-720 720,000 ** GBC/GBCP-726 726,000 ** DW-840 840,000 ** GBC/GBCP-825 825,000 **

A.O. SMITH TO RHEEM-RUUD CONVERSION CHART

49

Storage Tank Systems (**Unfired Storage Vessels) TJ-80(A) ** 80 ST80(A) ** 80

TJV-120M ** 120 ST120 ** 115

TJV-120A ** 120 ST120A ** 115

TJV-200 ** 200 ST200A ** 200

NOTE: See large volume storage tanks, page 40 and 41.

DW-960 960,000 ** GBC/GBCP-962 961,700 ** DW-1080 1,080,000 ** GBC/GBCP-1125 1,124,700 ** DW-1210 1,210,000 ** GBC/GBCP-1223 1,222,500 ** DW-1350 1,350,000 ** GBC/GBCP-1337 1,336,600 ** DW-1480 1,480,000 ** GBC/GBCP-1467 1,467,000 ** DW-1610 1,610,000 ** GBC/GBCP-1630 1,630,000 ** DW-1810 1,810,000 ** GBC/GBCP-1826 1,825,600 **

NOTE: ** Denotes less than 1 gallon storage capacity.

Page 27: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

50

A.O. SMITH RHEEM-RUUD

Model kW Gal Model kW Gal

Electric – Light Duty and Point-of-Use Products DEL-6 S 2.5 Max 6 EGSP6 6 Max 6

DEL-10 S 6 Max 10 EGSP10 6 Max 10

DEL-15 S 6 Max 15 EGSP15 6 Max 15

DEL-20 S 6 Max 20 EGSP20 6 Max 20

DEN/DEL-30 D 12 Max 30 ELD/ELDS30 12 Max 30

DEN/DEL-40 D 12 Max 40 ELD/ELDS40 12 Max 40

DEN/DEL-52 D 12 Max 50 ELD/ELDS52 12 Max 50

DEN-66 D 12 Max 66 ELD66 12 Max 65

DEN-80 D 12 Max 80 ELD80 12 Max 80

DEN-120 D 12 Max 119 ELD120 12 Max 120

A.O. SMITH TO RHEEM-RUUD CONVERSION CHART

51

Electric – Heavy Duty Products DRE/DVE-52 6 to 54 50 ES50/E50 6 to 54 50 DRE/DVE-80 6 to 54 80 ES85/E85 6 to 54 85 DRE/DVE-120 6 to 54 119 ES120/E120 6 to 54 120 DSE-10 3 to 6 10 E12A 3 to 9 13 DSE-20 3 to 18 20 E20A 3 to 18 20 DSE-30 3 to 24 30 E30A 3 to 36 30 DSE-40 3 to 36 40 E40A 3 to 36 40 DSE-50 6 to 45 50 E50A 6 to 54 50 DSE-65 6 to 54 65 E85A 6 to 54 85 DSE-80 6 to 54 80 E85A 6 to 54 85 DSE-100 6 to 54 100 E120A 6 to 54 120 DSE-120 6 to 54 120 E120A 6 to 54 120

NOTE: “DRE”, “DEL”, “DEN” use surface mounted thermostats. “DVE”, “DSE” use immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats.

Electric – Instantaneous/Booster Products CMC-5 6 to 54 5 E10 6 to 54 10 SU-20 6 to 54 20 E10 6 to 54 10

Page 28: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

52

AMERICAN RHEEM-RUUD

Model Btu/Hr. Gal Dia. Height Model Btu/Hr. Gal Dia. Height

DCG32 Series 75T125-5N 125,000 75 28-1/4" 72" G75-125 125,000 75 26-1/4" 65-1/2" 36S145-6N 145,000 36 28-1/4" 50-5/8" G37-200 199,900 35 26-1/4" 49-1/4" 75T160-6N 160,000 75 28-1/4" 72" G82-156 156,000 82 26-1/4" 68-13/16" 80T180-6N 180,000 80 28-1/4" 71-7/8" G76-180 180,000 76 26-1/4" 68-13/16" 80T199-6N 199,999 80 28-1/4" 71-7/8" G76-200 199,900 76 26-1/4" 68-13/16" 98T199-6N 199,999 98 28-1/4" 82-7/8" G91-200 199,900 91 26-1/4" 76-5/16" 80T250-6N(A) 250,000 80 28-1/4" 71-7/8" G72-250(A) 250,000 72 26-1/4" 71-1/16" 98T250-6N(A) 250,000 98 28-1/4" 82-7/8" G100-250(A) 250,000 100 30-1/4" 73-1/4" 75T300-7N(A) 300,000 75 28-1/4" 74-1/2" G72-300(A) 300,000 72 26-1/4" 71" 65T370-8N(A) 370,000 65 28-1/4" 73-3/8" G65-360(A) 360,000 65 26-1/4" 70-11/16" 65T399-8N(A) 399,999 65 28-1/4" 73-3/8" G65-400(A) 399,900 65 26-1/4" 70-11/16" 80T425-10N(A) 425,000 80 28-1/4" 83" GX90-550(A) 550,000 90 30" 74-1/2"

PVDCG32 Series 65T625-8N(A) 625,000 65 28-1/4" 69-3/8" GX90-640(A) 640,000 90 30" 74-1/2" 80T725-8N(A) 725,000 80 28-1/4" 79-5/8" GX90-715(A) 715,000 90 30" 74-1/2"

AMERICAN TO RHEEM-RUUD CONVERSION CHART

53

DCG31 Series

73T140-5N 140,000 73 28-1/4" 74-1/4" G82-156 156,000 82 26-1/4' 68-13/16" 76T180-6N 180,000 76 28-1/4" 74-1/4" G76-180 180,000 76 26-1/4" 68-13/16" 85S199-6N 199,999 85 30-1/4" 69" G76-200 199,900 76 26-1/4" 68-13/16" 100T199-6N 199,999 100 28-1/4" 78" G91-200 199,900 91 26-1/4" 76-5/16" 100S199-6N 199,999 100 30-1/4" 74-1/2" G100-200 199,900 100 30-1//4" 73-1/16" 100S250-6N(A) 250,000 100 30-1/4" 74-1/2" G100-250(A) 250,000 100 30-1/4" 73-1/4" 100S270-6N(A) 270,000 100 30-1/4" 74-1/2" G100-270(A) 270,000 100 30-1/4" 73-7/8" 100S300-7N(A) 300,000 100 30-1/4" 74-1/2" G100-310(A) 310,000 100 30-1/4" 75" 80L399-8N(A) 399,999 75 30-1/4" 71" G65-400(A) 399,900 65 26-1/4" 70-11/16" 80L505-10N(A) 505,000 80 30-1/4" 69" GX90-550(A) 550,000 90 30" 74-1/2"

PVCG32 Series

50T63-3NV 63,500 50 22" 70" GPV75-75E 75,000 75 26-1/4" 68" 75T80-3NV 80,000 75 26" 70-1/2" GPV75-75E 75,000 75 26-1/4" 68"

CG32 Series

75T75-4NV 74,500 75 26" 63-1/2" G75-75 75,000 75 26-1/4" 64-3/8" 100T88-4NV 88,000 100 28-1/4" 68-11/16" G100-75 75,000 100 26-1/4" 67-7/8"

Page 29: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

54

AMERICAN RHEEM-RUUD

Model kW Gal Model kW Gal

Electric – Light Duty and Point-of-Use Products LDCE30D 12 Max 30 ELDS30 12 Max 30

LDCE40D 12 Max 40 ELD40 12 Max 40

LDCE50D 12 Max 50 ELD52 12 Max 50

LDCE65D 12 Max 65 ELD66 12 Max 65

LDCE80D 12 Max 80 ELD80 12 Max 80

LDCE119D 12 Max 119 ELD120 12 Max 120

AMERICAN TO RHEEM-RUUD CONVERSION CHART

55

Electric – Heavy Duty Products ITCE/STCE-33 9 to 54 50 ES50/E50 6 to 54 50

ITCE/STCE-33 9 to 54 80 ES85/E85 6 to 54 85

ITCE/STCE-33 9 to 54 119 ES120/E120 6 to 54 120

AITCE/ASTCE-33 9 to 54 119 E120A 6 to 54 120

NOTE: “STCE” uses surface mounted thermostats. “ITCE” uses immersion thermostats.

NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats.

Storage Tank Systems (**Unfired Storage Vessels) CST52-80T ** 80 ST80 ** 80

CST52-120T ** 119 ST120 ** 115

ACST52-120T ** 120 ST120A ** 115

ACST52-200T ** 200 ST200A ** 200

NOTE: See large volume storage tanks, page 40 and 41.

Page 30: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

56

BRADFORD WHITE RHEEM-RUUD

Model Btu/Hr. Gal Dia. Height Model Btu/Hr. Gal Dia. Height T&S Series 75T-80 80,000 75 26" 63-3/4" G75-75 75,000 75 26-1/4" 64-3/8" 100T-88 88,000 100 28-1/4" 68-5/8" G100-75 75,000 100 26-1/4" 67-7/8" D-75T-125-3N 125,000 75 28-1/4" 72-1/8" G75-125 125,000 75 26-1/4" 65-1/2" D-38T-155 155,000 38 28-1/4" 51" G37-200 199,900 35 26-1/4" 49-1/4" D-75T-160-3N 160,000 75 28-1/4" 72-1/8" G82-156 156,000 82 26-1/4" 68-13/16" D-80T-180-3N 180,000 80 28-1/4" 71-7/8" G76-180 180,000 76 26-1/4" 68-13/16" D-80T-199-3N 199,999 80 28-1/4" 71-7/8" G76-200 199,900 76 26-1/4" 68-13/16" D-100T-199-3N 199,999 98 28-1/4" 83" G91-200 199,900 91 26-1/4" 76-5/16" D-100S-199-3N 199,999 100 30-1/4" 74-1/4" G100-200 199,990 100 30-1/4" 73-1/16" D-80T-250-3N(A) 250,000 80 28-1/4" 71-7/8" G72-250(A) 250,000 72 26-1/4" 71-1/16" D-100S-250-3N(A) 250,000 100 30-1/4" 74-1/4" G100-250(A) 250,000 100 30-1/4" 73-1/4" D-100T-250-3N(A) 250,000 98 28-1/4" 83" G100-250(A) 250,000 100 30-1/4" 73-1/4" D-100S-270-3N(A) 270,000 100 30-1/4" 74-1/4" G100-270(A) 270,000 100 30-1/4" 73-7/8" D-75T-300-3N(A) 300,000 75 28-1/4" 74" G72-300(A) 300,000 72 26-1/4" 71" D-65T-370-3N(A) 370,000 65 28-1/4" 74" G65-360(A) 360,000 65 26-1/4" 70-11/16" D-65T-399-3N(A) 399,999 65 28-1/4" 74" G65-400(A) 399,900 65 26-1/4" 70-11/16" D-80S-399-3N(A) 399,999 80 30-1/4" 77-1/4" G85-400(A) 399,900 85 26-1/4" 78-13/16" D-80T-425-3N(A) 425,000 80 28-1/4" 83" GX90-550(A) 550,000 90 30" 74-1/2" D-80T-505-3N(A) 505,000 80 28-1/4" 83" GX90-550(A) 550,000 90 30" 74-1/2"

BRADFORD WHITE TO RHEEM-RUUD CONVERSION CHART

57

D-80S-512-3N(A) 512,000 80 30-1/4 75-3/4" GX90-550(A) 550,000 90 30" 74-1/2" D-65T-625-3N(A) 625,000 65 28" 68-7/8" GX90-640(A) 640,000 90 30" 74-1/2" D-80T-725-3N(A) 725,000 80 28" 79-1/8" GX90-715(A) 715,000 90 30" 74-1/2"

L Series D-100L-199 199,999 100 30-1/4" 74-3/4" G100-200 199,990 100 30-1/4" 73-1/16" D-100L-250(A) 250,000 100 30-1/4" 74-3/4" G100-250(A) 250,000 100 30-1/4" 73-1/4" D-100L-270(A) 270,000 100 30-1/4" 74-3/4" G100-270(A) 270,000 100 30-1/4" 73-7/8" D-100L-300(A) 300,000 100 30-1/4" 75-1/2" G100-310(A) 310,000 100 30-1/4" 75" D-80L-399(A) 399,999 80 30-1/4" 71" G65-400(A) 399,900 65 26-1/4" 70-11/16" D-80L-450(A) 450,000 80 30-1/4" 69" GX90-550(A) 550,000 90 30" 74-1/2" D-80L-505(A) 505,000 80 30-1/4" 69" GX90-550(A) 550,000 90 30" 74-1/2"

TW & PDV Series TW50T-65-3N 65,000 48 22" 66-1/4" GPV75-75E 75,000 75 26-1/4" 68" TW75T-75-3N 75,000 75 26" 69-1/2" GPV75-75E 75,000 75 26-1/4" 68" PDV100S-200-3N 199,900 100 28-1/4" 77" GP100-200 199,900 100 30-1/4" 81-3/4"

High Efficiency Models EF60T-125E-3N(A) 125,000 60 28-1/4" 57" HE80-130 130,000 80 23-1/2" 72" EF60T-150E-3N(A) 150,000 60 28-1/4" 57" HE80-160 160,000 80 23-1/2" 72" EF60T-199E-3N(A) 199,999 60 28-1/4" 57" HE80-199 199,000 80 23-1/2" 72" EF100T-150-3N(A) 150,000 100 28-1/4" 78" GHE100-130 130,000 100 26-1/4" 78-3/4" EF100T-199-3N(A) 199,999 100 28-1/4" 78" GHE100-160 160,000 100 26-1/4" 78-3/4" EF100T-250-3N(A) 250,000 100 28-1/4" 78" GHE100200(A) 199,900 100 26-1/4" 78-3/4" EF100T-300-3N(A) 300,000 100 28-1/4" 78" GHE100-250(A) 250,000 100 26-1/4" 78-3/4"

Page 31: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

58

BRADFORD WHITE RHEEM-RUUD

Model Btu/Hr. Gal Model Btu/Hr. Gal

Gas – Hot Water Supply Heaters

L-I-T1 Series 90-5N-PF1 90,000 ** GBB/GBBP-136 136,000 **

135-5N-PF1 135,000 ** GBB/GBBP-136 136,000 **

180-5N-PF1 180,000 ** GBC/GBCP-186 181,000 **

225-5N-PF1 225,000 ** GBC/GBCP-186 181,000 **

270-5N-PF1 270,000 ** GBC/GBCP-264 264,000 **

315-5N-PF9 315,000 ** GBC/GBCP-331 334,000 **

360-5N-PF9 360,000 ** GBC/GBCP-399 399,000 **

495-5N-PF9 495,000 ** GBC/GBCP-512 511,500 **

645-5N-PF9 645,000 ** GBC/GBCP-627 627,000 **

745-5N-PF9 745,000 ** GBC/GBCP-726 726,000 **

985-5N-PF9 985,000 ** GBC/GBCP-962 961,700 **

BRADFORD WHITE TO RHEEM-RUUD CONVERSION CHART

59

Storage Tank Systems (**Unfired Storage Vessels) M-3-ST80R5 ** 80 ST80(A) ** 80

M-3-ST120R5 ** 119 ST120(A) ** 115

M-3-ST120R5(A) ** 119 ST120A ** 115

M-3-ST200R5(A) ** 200 ST200A ** 200

NOTE: See large volume storage tanks, page 40 and 41.

1255-5N-PF9 1,255,000 ** GBC/GBCP-1223 1,222,500 **

1435-5N-PF9 1,435,000 ** GBC/GBCP-1467 1,467,000 **

1795-5N-PM9 1,795,000 ** GBC/GBCP-1826 1,825,600 **

2065-5N-PM9 2,065,000 ** (2)-GBC/GBCP-1125 2,249,400 **

2620-5N-PM9 2,620,000 ** (2)-GBC/GBCP-1337 2,673,200 **

3080-5N-PM9 3,080,000 ** (2)-GBC/GBCP-1467 2,934,000 **

NOTE: ** Denotes less than 1 gallon storage capacity.

Page 32: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

60

BRADFORD WHITE RHEEM-RUUD

Model kW Gal Model kW Gal

Electric – Heavy Duty Products 12A-KW-3 3 to 9 12 E12A 3 to 9 12 20A-KW-3 3 to 18 20 E20A 3 to 18 20 30A-KW-3 3 to 36 30 E30A 3 to 36 30 40A-KW-3 3 to 36 40 E40A 3 to 36 40 M-II-50SF/CF 6 to 54 50 ES/E50(A) 6 to 54 50 M-II-80SF/CF 6 to 54 80 ES/E85(A) 6 to 54 85 M-II-120SF/CF(A) 6 to 54 119 ES/E120(A) 6 to 54 120 NOTE: “SF” uses surface mounted thermostats. “CF” uses immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats. NOTE: (A) refers to ASME availability. Limited to “E” products. Typical Rheem-Ruud Configuration: E50-(kW)or ES50-(kW) If kW = 36; Example: E50-36 or ES50-36

BRADFORD WHITE TO RHEEM-RUUD CONVERSION CHART

Electric – Instantaneous/Booster Products L-I-6-3CF 6 to 58 5 E10 6 to 54 10

Typical Bradford White Configuration: L-I-6-(kW)-3CF Example: L-I-6-36-3CF

61

Electric – Light Duty and Point-of-Use Products LD-6U3-1CO15 1.5 Max 6 EGSP6 6 Max 6

LD-12U3-1C015 1.5 Max 12 EGSP10 6 Max 10

LD-20U3-1C015 6 Max 19 EGSP20 6 Max 20

LD-30U3-1C015 6 Max 30 EGSP30 6 Max 30

LD-30L3-3C045 12 Max 30 ELDS30 12 Max 30

LD-40L3-3CO45 12 Max 40 ELDS40 12 Max 40

LD-50L3-3C045 12 Max 50 ELDS52 12 Max 50

LD-WH6U3-1C015 1.5 Max 6 EGSP6 6 Max 6

LD-WH12U3-1C015 1.5 Max 12 EGSP10 6 Max 10

LD-WH20L3-1C015 6 Max 19 EGSP20 6 Max 20

LD-WH30L3-1C015 6 Max 30 EGSP30 6 Max 30

LD-40S3-3C045 12 Max 40 ELD40 12 Max 40

LD-50S3-3CO45 12 Max 50 ELD52 12 Max 50

LD-65R3-3C045 12 Max 65 ELD66 12 Max 65

LD-80R3-3C045 12 Max 80 ELD80 12 Max 80

LC-120R3-3C045 12 Max 120 ELD120 12 Max 120

Page 33: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

62

LOCHINVAR RHEEM-RUUD

Model Btu/Hr. Gal Dia. Height Model Btu/Hr. Gal Dia. Height

CNR Series CNR080-075 80,000 75 26" 63-3/4" G75-75 75,000 75 26-1/4" 64-3/8" CNR090-100 88,000 100 28-1/4" 68-5/8" G100-75 75,000 100 26-1/4" 67-7/8" CNR145-035-DF9 145,000 35 28-1/4' 50-5/8" G37-200 199,900 35 26-1/4" 49-1/4" CNR125-075-DF9 125,000 75 28-1/4" 72-1/8" G75-125 125,000 75 26-1/4" 65-1/2" CNR160-075-DF9 160,000 75 28-1/4" 72-1/8" G82-156 156,000 82 26-1/4" 68-13/16" CNR180-080-DF9 180,000 80 28-1/4" 71-7/8" G76-180 180,000 76 26-1/4" 68-13/16" CNR200-080-DF9 199,999 80 28-1/4" 71-7/8" G76-200 199,900 76 26-1/4" 68-13/16" CNR200-100-DF9 199,999 98 28-1/4" 83" G91-200 199,900 91 26-1/4" 76-5/16" CNR199-100-DF9 199,999 100 30-1/4" 74-1/4" G100-200 199,990 100 30-1/4" 73-1/16" CNR250-100-DF9 250,000 98 28-1/4" 83" G100-250 250,000 100 30-1/4" 73-1/4" CNR300-075-DF9 300,000 75 28-1/4" 74" G72-300 300,000 72 26-1/4" 71" CNR370-065-DF9 370,000 65 28-1/4" 74" G65-360 360,000 65 26-1/4" 70-11/16" CNR400-080-DF9 399,999 80 30-1/4" 77-1/4" G85-400 399,900 85 26-1/4" 78-13/16"

LOCHINVAR TO RHEEM-RUUD CONVERSION CHART

63

CNR500-080-DF9 505,000 80 28-1/4" 83" GX90-550(A) 550,000 90 30" 74-1/2" CNR625-065-DF9 625,000 65 28" 68-7/8" GX90-640(A) 640,000 90 30" 74-1/2" CNR725-080-DF9 725,000 80 28" 79-1/8" (2)-G65-360 720,000 130 ***** 70-11/16"

CNA (ASME) Series CNA251-100-DF9 250,000 98 28-1/4" 83" G100-250(A) 250,000 100 30-1/4" 73-1/4" CNA301-075-DF9 300,000 75 28-1/4" 74" G72-300(A) 300,000 72 26-1/4" 71" CNA371-065-DF9 370,000 65 28-1/4" 74" G65-360(A) 360,000 65 26-1/4" 70-11/16" CNA401-080-DF9 399,999 80 30-1/4" 77-1/4" G85-400(A) 399,900 85 26-1/4" 78-13/16" CNA501-080-DF9 505,000 80 28-1/4" 83" GX90-550(A) 550,000 90 30" 74-1/2" CNA625-065-DF9 625,000 65 28" 68-7/8" GX90-640(A) 640,000 90 30" 74-1/2" CNA725-080-DF9 725,000 80 28" 79-1/8" GX90-715(A) 715,000 90 30" 74-1/2"

PNR Series PNR200-100 199,999 100 28-1/4" 77-1/4" GP100-200 199,900 100 30-1/4" 81-3/4"

Page 34: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

64

LOCHINVAR RHEEM-RUUD

LOCHINVAR TO RHEEM-RUUD CONVERSION CHART

Model Btu/Hr. Gal Model Btu/Hr. Gal

Gas – Hot Water Supply Heaters“Copper-Pak” Products CPN180-85 180,000 85 G76-180 180,000 76 CPN199-85 199,000 85 G76-200 199,900 76

“Better Idea” Products RWN090PM-F1 90,000 ** GBB/GBBP-136 136,000 ** RWN135PM-F1 135,000 ** GBB/GBBP-136 136,000 ** RWN180PM-F1 180,000 ** GBC/GBCP-186 181,000 ** RWN199PM-F1 199,000 ** GBC/GBCP-186 181,000 ** RWN225PM-F1 225,000 ** GBC/GBCP-264 264,000 ** RWN270PM-F1 270,000 ** GBC/GBCP-264 264,000 ** RWN315PM-F9 315,000 ** GBC/GBCP-331 334,000 ** RWN360PM-F9 360,000 ** GBC/GBCP-399 399,000 ** RWN399PM-F9 399,000 ** GBC/GBCP-399 399,000 ** RWN500PM-F9 500,000 ** GBC/GBCP-512 511,500 **

65

Storage Tank Systems (**Unfired Storage Vessels) RJS080 ** 78 ST80 ** 80 RJS085 ** 85 ST80 ** 80 RJS120 ** 119 ST120 ** 115 RJA120 ** 119 ST120A ** 115 RJA200 ** 200 ST200A ** 200

NOTE: See large volume storage tanks, page 40 and 41.

CWN495PM 495,000 ** GBC/GBCP-512 511,500 ** CWN645PM 645,000 ** GBC/GBCP-627 627,000 ** CWN745PM 745,000 ** GBC/GBCP-726 726,000 ** CWN985PM 985,000 ** GBC/GBCP-962 961,700 ** CWN1255PM 1,255,000 ** GBC/GBCP-1223 1,222,500 ** CWN1435PM 1,435,000 ** GBC/GBCP-1467 1,467,000 ** CWN1795PM 1,795,000 ** GBC/GBCP-1826 1,825,600 ** CWN2065PM 2,065,000 ** (2)-GBC/GBCP-1125 2,249,400 ** CWN2620PM 2,620,000 ** (2)-GBC/GBCP-1337 2,673,200 ** CWN3080PM 3,080,000 ** (2)-GBC/GBCP-1467 2,934,000 ** NOTE: ** Denotes less than 1 gallon storage capacity. NOTE: “PM” refers to pump mounted models. Also available without pumps. NOTE: “P” refers to pump mounted Rheem-Ruud models.

Page 35: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

66

LOCHINVAR RHEEM-RUUD

Model kW Gal Model kW Gal

Electric – Light Duty and Point-of-Use Products ETX/ETW030KK 12 Max 30 ELD30 12 Max 30

ESX/ESW030KK 12 Max 30 ELDS30 12 Max 30

ETX/ETW040KK 12 Max 40 ELD40 12 Max 40

ESX/ESW040KK 12 Max 40 ELDS40 12 Max 40

ETX/ETW052KK 12 Max 50 ELD52 12 Max 50

ESX/ESW050KK 12 Max 50 ELDS52 12 Max 50

ETX/ETW066KK 12 Max 65 ELD66 12 Max 65

ETX/ETW082KK 12 Max 80 ELD80 12 Max 80

ETX/ETW120KK 12 Max 120 ELD120 12 Max 120

NOTE: “ETX/ESX” refers to 480 volt, 3 phase products. “ETW/ESW” refers to 277 volt, 1 phase products. NOTE: “ELD/ELDS” models are available in 208, 240, 277 or 480 volt (1 or 3 phase) configurations.

LOCHINVAR TO RHEEM-RUUD CONVERSION CHART

67

Electric – Heavy Duty Products HS*(kW)-052 9 to 36 52 ES50 6 to 54 50

HS*(kW)-082 9 to 54 82 ES85 6 to 54 85

HS*(kW)-120(A) 9 to 54 118 ES120 6 to 54 120

HC*(kW)-052 9 to 36 52 E50(A) 6 to 54 50

HC*(kW)-082 9 to 54 82 E85(A) 6 to 54 85

HC*(kW)-120(A) 9 to 54 118 E120(A) 6 to 54 120

Electric – Instantaneous/Booster Products SB*-(kW) 6 to 58 5 E10 6 to 54 10

Note: * Refers to voltage/phase:

A – 240 Volt, 1 Phase B – 240 Volt, 3 Phase

J – 208 Volt, 1 Phase K – 208 Volt, 3 Phase

P – 240 Volt, 1/3 Phase T – 208 Volt, 1/3 Phase

W – 277 Volt, 1 Phase X – 480 Volt, 3 Phase

R – Special - Must Specify

Page 36: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

68

STATE RHEEM-RUUD

Model Btu/Hr. Gal Dia. Height Model Btu/Hr. Gal Dia. Height

Gas Water Heaters SBT75-75NE 75,100 75 26-1/4 67-1/2" G75-75 75,000 75 26-1/4" 64-3/8" SBT100-75NE 75,100 100 28" 72" G100-75 75,000 100 26-1/4" 67-7/8" SBF75-120NE 120,000 75 24" 76-3/4" G75-125 125,000 75 26-1/4" 65-1/2" SBF75-140NE 140,000 75 24" 76-3/4" G82-156 156,000 82 26-1/4" 68-13/16" SBF30-150NE 150,000 30 28" 49" G37-200 199,900 35 26-1/4" 49-1/4" SBF80-180NE 180,000 80 28" 73-1/2" G76-180 180,000 76 26-1/4" 68-13/16" SBF30-199NE 199,900 30 28" 49" G37-200 199,900 35 26-1/4" 49-1/4" SBF80-199NE 199,900 80 28" 73-1/2" G76-200 199,900 76 26-1/4" 68-13/16" SBF100-199NES 199,900 100 30-1/4" 71" G100-200 199,900 100 30-1/4" 73-1/16" SBF100-199NET 199,900 100 28" 83" G91-200 199,900 91 26-1/4" 76-5/16" SBF30-199NE 199,900 30 28" 49" G37-200 199,900 35 26-1/4" 49-1/4" SBF30-225NE(A) 225,000 30 28" 49" G37-200 199,900 35 26-1/4" 49-1/4" SBF75-250NE(A) 250,000 75 28" 75" G72-250(A) 250,000 72 26-1/4" 71-1/16" SBF100-260NES(A) 260,000 100 30-1/4" 74" G100-270(A) 270,000 100 30-1/4" 73-7/8" SBF100-260NET(A) 260,000 100 28" 84" G100-270(A) 270,000 100 30-1/4" 73-7/8"

STATE TO RHEEM-RUUD CONVERSION CHART

69

SBF75-300NE(A) 300,000 75 28" 75-1/2" G72-300(A) 300,000 72 26-1/4" 71" SBF70-360NE(A) 360,000 70 28" 72-3/4" G65-360(A) 360,000 65 26-1//4" 70-11/16" SBF100-400NE(A) 399,900 100 30-1/4" 77" G100-400(A) 399,900 100 30-1/4" 76" SBF80-500NE(A) 500,000 80 30-1/4" 77-1/2" GX90-550(A) 550,000 90 30" 74-1/2" SBF80-725NE(A) 725,000 80 30-1/4" 75-1/2" GX90-715(A) 715,000 90 30" 74-1/2" SDV100-199NE 199,900 100 30-1/4" 75" GP100-200 199,900 100 30-1/4" 81-3/4"

NOTE: (A) denotes ASME construction available.

Induced Draft Models

SBN250(A) 250,000 100 27-3/4" 72" GD-100-250(A) 250,000 100 30-1/4" 73-1/2" SBN275(A) 275,000 100 27-3/4" 72" GD-100-270(A) 270,000 100 30-1/4" 73-1/2" SBN310(A) 310,000 85 27-3/4" 73" GD-100-310(A) 310,000 100 30-1/4" 73-1/2" SBN366(A) 366,000 85 27-3/4" 73" GD-100-360(A) 360,000 100 30-1/4" 73-1/2"

High Efficiency Models

SUF-120 125,000 60 27-3/4" 55-1/2" HE80-130 130,000 80 23-1/2" 72" SUF-150 150,000 100 27-3/4" 74-1/2" GHE100-160 160,000 100 26-1/4" 78-3/4" SUF-199 199,000 100 27-3/4" 74-1/2" GHE100-200(A) 199,900 100 26-1/4" 78-3/4" SUF-250(A) 240,000 100 27-3/4" 74-1/2" GHE100-250(A) 250,000 100 26-1/4" 78-3/4" SUF-300(A) 300,000 130 33" 74" GHE100-300(A) 300,000 100 26-1/4" 78-3/4"

Page 37: POCKET GUIDE Rheem-Ruud Commercialcdn.spsmsys.com/images/products/pdf/rhe01/st120.pdfPOCKET GUIDE Rheem-Ruud Commercial ... HE55-160 55 160,000 95% 461 368 307 263 230 205 184 167

70

STATE RHEEM-RUUD

Model kW Gal Model kW Gal

Electric – Point-of-Use and Light Duty Products CPE 6 10MSA 3.8 Max 6 EGSP6 6 Max 6

CPE 10 10MSA 6 Max 10 EGSP10 6 Max 10

CPE 17 10MSA 6 Max 17 EGSP15 6 Max 15

CPE 20 10MSA 6 Max 20 EGSP20 6 Max 20

CPE 30 10MSA 12 Max 30 EGSP30 6 Max 30

CPE 40 20LSA 12 Max 40 ELDS40 12 Max 40

CPE 50 20LSA 12 Max 47 ELDS52 12 Max 50

CPE 30 20RTA 12 Max 30 ELD30 12 Max 30

CPE 40 20RTA 12 Max 40 ELD40 12 Max 40

CPE 52 20RTA 12 Max 50 ELD50 12 Max 50

CPE 66 20RTA 12 Max 66 ELD66 12 Max 65

CPE 82 20RTA 12 Max 82 ELD80 12 Max 80

CPE 120 20RTA 12 Max 119 ELD120 12 Max 120

STATE TO RHEEM-RUUD CONVERSION CHART

71

Electric – Heavy Duty Products SB6-10 3 to 9 10 E12A 3 to 9 12

SB6-20 3 to 18 20 E20A 3 to 18 20

SB6-30 3 to 36 30 E30A 3 to 36 30

SB6-40 3 to 36 40 E40A 3 to 36 40

SB6-52-(kW)**(A) 6 to 81 52 ES50/E50(A) 6 to 54 50

SB6-82-(kW)**(A) 6 to 81 82 ES85/E85(A) 6 to 54 85

SB6-120-(kW)**(A) 6 to 81 119 ES120/E120(A) 6 to 54 120

NOTE: ** Refers to “SFE” which uses surface mounted thermostats. “IFE” uses immersion thermostats. NOTE: “ES” models use surface mounted thermostats. “E” models use immersion thermostats.

Storage Tank Systems (**Unfired Storage Vessels) PV-82-0ORT(A) ** 82 ST80(A) ** 80

PV-120-0ORT(A) ** 119 ST120(A) ** 115

PV-200-0ORTA ** 200 ST200A ** 200

NOTE: See large volume storage tanks, page 40 and 41.