RheemResidential
G A S , E L E C T R I C & S O L A R T A N K T Y P E ❘ T A N K L E S S ❘ O N - L I N E P R O D U C T G U I D E : R H E E M . C O M
pocket guide
Printed in U.S.A. Form No. 105-61 Rev. 18 05/06 WP
Rheem National Customer Service
DIVISION OFFICE _______________________ 334-260-1500CUSTOMER SERVICE, WARRANTY, PARTS ___ 1-800-621-5622FAX __________________________________ 1-800-535-9538TECHNICAL SERVICE (1-800-432-8373) _____ 1-800-HEATER3WEBSITE ______________________________ rheem.com
Rheem Water Heating101 Bell RoadMontgomery Alabama 36117-4305
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Table of Contents
GAS • Tankless 7.4...............................2-3
• Tankless 4.2...............................4-5
• Professional GUARDIAN SYSTEM...........6-7
• Professional Heavy Duty ...........8-9
• Fury GUARDIAN SYSTEM ...................10-11
• Fury Heavy Duty....................12-13
• PowerVent GUARDIAN SYSTEM .........14-15
• PowerVent HIGH EFFICIENCY ...........16-17
• Fury Direct Vent .....................18-19
• Warrior MANUFACTURED HOUSING...........20-21
• Warrior DV MANUFACTURED HOUSING .....22-23
• Warrior DVX MANUFACTURED HOUSING ..24-25
ELECTRIC• Professional ...........................26-27
• Marathon................................28-29
• Fury........................................30-31
• Warrior MANUFACTURED HOUSING...........32-33
• Marathon Point-of-Use...........34-35
• Point-of-Use ...........................36-37
• Table Top................................38-38
SOLAR• Solaraide................................40-41
• Solaraide HE..........................42-43
MISCELLANEOUS• ProtectionPlus .............................44
• Lifeguard Electric Element..........45
• EverKleen....................................46
• Accessories.................................47
• Therm-X-Guard...........................48
1
RHEEM NATIONALCUSTOMER SERVICE
SEE BACK COVER
High Volume Tankless Gas Water Heater – 7.4 Gallons Per Minute
Indoor and Outdoor Models Available� 10-Year Limited Warranty on Heat Exchanger* � 3-Year Limited Warranty on Parts*
• Continuous hot water – 7.4 gallons perminute at a 45° F rise
• Energy saving design• Compact, space saving design• Intelligent electronic controls designed to
increase energy efficiency and safety• Self diagnostic program• Digital display shows temperature setting and
maintenance codes on remote control• Exclusive oxygen depletion sensor• Exclusive film wrap overheat limiter• Built-in electric blower• Indoor units use 4" Category III stainless
steel vents and vent horizontally or vertically• Maximum horizontal or vertical vent run is 47
feet 6 inches including one 90 degree elbow
• Indoor models supplied with a 120 volt power cord
• Supplied remote control (USC1-117) allowstemp. settings up to 120˚ F
• Optional remote control (UMC-117) allowstemp. settings up to 140˚ F
• Indoor and outdoor models feature freezeprotection to -30° F
• Low NOx emissions meet SCAQMD rule1121 requirements (pending certification)
* See Residential Warranty Information Brochure forcomplete warranty information.
Energy Factor and Average AnnualOperating Costs based on D.O.E.(Department of Energy) testprocedures. D.O.E. national average fuel rate natural gas91¢/therm; LP $1.23/gallon.
®
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS WATER FLOW RATE SHIP. EST. ANN.INPUT TEMP. GPM @ 77° GPM @ 45° CONNECTION WEIGHT ENERGY OPERATING
MODEL NUMBER BTU/HR. TYPE RANGE* RISE MAX. RISE MAX. WATER GAS HEIGHT WIDTH DEPTH VENT (LBS.) FACTOR COST
RTG-74PVN 19,000 - Indoor 100° to 4.2 7.4 3/4 3/4 25-3/8 14-7/8 11-1/8 4 55 .82 $167(NAT. GAS) 199,900 140° F
RTG-74PVP 19,000 - Indoor 100° to 4.2 7.4 3/4 3/4 25-3/8 14-7/8 11-1/8 4 55 .82 $246(LP GAS) 199,900 140° F
RTG-74XN 19,000 - Outdoor 100° to 4.2 7.4 3/4 3/4 25-3/8 14-7/8 11-1/8 N/A 55 .82 $167(NAT. GAS) 199,900 140° F
RTG-74XP 19,000 - Outdoor 100° to 4.2 7.4 3/4 3/4 25-3/8 14-7/8 11-1/8 N/A 55 .82 $246(LP GAS) 199,900 140° F
Maximum Hot Water Flow Rate and Temperature Rise
Temp. Rise (°F) 45 50 60 70 80 90 100
Water Flow (GPM) 7.4 6.7 5.6 4.8 4.2 3.7 3.3
Minimum flow rate required to initiate heating cycle .66 gpm.
3
* Factory set maximum temperature is 120° F with supplied USC1-117 remote control.For temperatures up to 140˚ F, remote control (UMC-117) is required – sold separately.
• For installations above 3,280 feet a high altitude chip is required. Refer to Rheem pricelist or consult factory for details.
• Consult factory for information on sizing the application
Indoor models vent horizontally or verticallyThis water heater has a built-in electric blower to force exhaust gas to the outside. Category III stainless steel vent (UL1738 certified) is required inorder to avoid damage frompossible condensation. Type “B” vents are notpermitted. Side-wall
Side-wall
Qualifies for up to a $300
Energy Tax Credit!
5
* Factory set maximum temperature is 120° F.• For installations above 3,280 feet a high altitude chip is required.
Refer to Rheem price list or consult factory for details.• Consult factory for information on sizing the application
Maximum Hot Water Flow Rate and Temperature Rise
Temp. Rise (°F) 45 50 60 70 80 90 100
Water Flow (GPM) 4.2 3.8 3.2 2.7 2.4 2.1 1.9
Minimum flow rate required to initiate heating cycle .92 gpm.
VentingThis water heater has a built-in electricblower to force the exhaust gas to theoutside. 3" Category III stainless steel vent(UL1738 certified) is required in order toavoid damage from possible condensation.
A RTG20000BM vent adapter orequivalent approved vent adapter isrequired for vent connection. Contactdistributor or factory for price andavailability.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS WATER FLOW RATE SHIP. EST. ANN.INPUT TEMP. GPM @ 77° GPM @ 45° CONNECTION WEIGHT ENERGY OPERATING
MODEL NUMBER BTU/HR. TYPE RANGE* RISE MAX. RISE MAX. WATER GAS HEIGHT WIDTH DEPTH VENT (LBS.) FACTOR COST
RTG-42PVN 31,500 - Indoor 100° to 2.4 4.2 3/4 1/2 22-1/4 13-3/4 5-1/8 3 35 .81 $168(NAT. GAS) 118,000 140° F
RTG-42PVP 31,500 - Indoor 100° to 2.4 4.2 3/4 1/2 22-1/4 13-3/4 5-1/8 3 35 .81 $250(LP GAS) 118,000 140° F
Tankless Gas Water Heater – 4.2 Gallons Per Minute
Indoor Models� 10-Year Limited Warranty on Heat Exchanger* � 3-Year Limited Warranty on Parts*
• Continuous hot water – 4.2 gallonsper minute at a 45° F rise
• Energy saving design• Compact, space saving design• Intelligent electronic controls
designed to increase energyefficiency and safety
• Self diagnostic program• Digital display shows temperature
setting and maintenance codes• Exclusive oxygen depletion sensor• Exclusive film wrap overheat limiter• Built-in electric blower
• Vents horizontally or vertically• Maximum vent run is 36 feet 2
inches including one 90 degreeelbow
• Uses 3" Category III stainless steelvent
• Supplied with a 120 volt power cord• Low NOx emissions meet
SCAQMD rule 1121 requirements* See Residential Warranty Information Brochure for
complete warranty information.
Energy Factor and Average AnnualOperating Costs based on D.O.E.(Department of Energy) testprocedures. D.O.E. nationalaverage fuel rate natural gas91¢/therm; LP $1.23/gallon.
®
Qualifies for up to a $300
Energy Tax Credit!
Professional™Now with the Guardian System™
Available in 40 and 50 Gallon Tall – 40 Gallon Short Gas Models� 8-Year* Limited Tank and Parts Warranty with a Professional Installation.� With ProtectionPlus™ the 8-Year Limited Tank Warranty Becomes 12 Years! SEE PAGE 44.
Guardian System™
• One-of-a-kind air/fuel shut-off device offers doubleprotection
• Maintenance free – no filter to clean• Standard replacement partsEnvironmentally Friendly Burner• Low NOx design for low nitrous oxide emissionsSelf-Cleaning• EverKleen™ patented system fights sediment build-up• Reduces fuel costs• Provides more hot waterEasy to Light• No matches requiredEnergy Efficient• More hot water at low operating cost
High Altitude Compliant• All models are certified for applications up to 6,000
feet above sea level. Some models are certified up to10,200 feet above sea level. Check factory for listing
Longer Life• Patented magnesium anode rod design incorporates
a special resistor that protects the tank from rustPlus…• Brass drain valve and temperature and pressure
relief valve are included• Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements* See Residential Warranty Information Brochure
for complete warranty information.®
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuel ratenatural gas 91¢/therm; LP $1.23/gallon.
Get4 MORE YEARSwith ProtectionPlus™
7
Rheem Guardian System Features…
Flame Arrestor PlateA specially-designed flame arrestorprevents ignition of vapors outside thecombustion chamber.
Maintenance FreeSuperior air filtration prevents theflame arrestor from becoming cloggedby lint, dust and oil.
Exclusive Combustion Shut-off SystemShould a spill incident occur, the Guardian System shuts offthe gas supply and the air supply preventing a sustainedvapor burn in the combustion chamber.
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: RHG PRO40-40PF.• For SCAQMD rule 1121 compliance models (California only), add “SQ” suffix to the model number. Example: 22V40 PROFSQ.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO WATER HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. HT. TO TANK GAS VENT CONN. SIDE WATER WT. FACTOR OPER. COSTCAP. MODEL NUMBER NAT. LP NAT. LP NAT. VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. (LBS) NAT. NAT.
40 22V40 PROF 38 – 38.4 – 73 61-3/4 58-3/8 18-1/8 14-1/2 3 8 52-1/4 3/4 120 0.59 $231
38 42V40 PROF 40 34 40.4 34.3 68 61-1/2 57-3/4 19-3/4 14-1/2 3 8 52-1/4 3/4 125 0.60 $227
40 RHG PRO40-40F 40 34 40.4 34.3 68 63-1/4 59-3/4 21 14-1/2 3 8 53-1/2 3/4 135 0.62 $220
50 22V50 PROF 38 – 38.4 – 90 61-1/2 58-1/4 20-1/8 14-1/2 3 8 51-3/8 3/4 130 0.58 $235
50 42V50-40 PROF 40 36 40.4 36.4 83 61-1/2 58 21-3/4 14-1/2 3 8 52-1/2 3/4 150 0.58 $235
50 RHG PRO50-40F 40 36 40.4 36.4 83 62-1/4 58-3/4 23 14-1/2 3 8 52-1/2 3/4 165 0.62 $220
50 RHG PRO50-50F 50 – 50.5 – 83 62 58 21-3/4 14-1/2 4 8 52-1/2 3/4 150 0.58 $235
40 42V40SPROF 40 36 40.4 36.4 72 53-7/8 50-1/2 20-1/8 14-1/2 3 8 44 3/4 130 0.59 $231
50 42V50SPROF 40 36 40.4 36.4 84 54-1/4 49-3/4 22-1/4 14-1/2 3 8 44 3/4 158 0.59 $231SHORT
TYPE
TALL
Professional™ Heavy Duty Gas Water Heaters
Available in 60, 75 and 100 Gallon Tall Gas Models� 8-Year* Limited Tank and Parts Warranty with a Professional Installation.� With ProtectionPlus™ the 8-Year Limited Tank Warranty Becomes 12 Years! SEE PAGE 44.
• Designed for high volume applications• High BTU input for fast recovery• Extra durable brass drain valve• Heat saving flue baffle design• Temperature and pressure relief valve
included• Extra durable high temperature dip tube to
meet the most stringent plumbing codes
• Meets or exceeds National ApplianceEnergy Conservation Act (NAECA)requirements
* See Residential Warranty Information Brochure for complete warranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuel rate natural gas 91¢/therm; LP $1.23/gallon.
Get4 MORE YEARSwith ProtectionPlus™
®
9
* SCAQMD rule 1121 compliance models.• Specify LP gas when ordering. Add “P” suffix to the model number:
Example: RHG PRO75-70P.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO WATER HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. HT. TO TANK GAS VENT CONN. SIDE WATER WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT. LP NAT. LP NAT. LP VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. (LBS) NAT. NAT.
60 RHG PRO60-50NT* 50 50 50.5 50.5 106 106 60 56 23 13-1/4 4 8 48-1/2 3/4 180 0.56 $244
75 RHG PRO75-70N* 70 69 70.7 69.7 109 109 64-1/2 60-1/2 26-1/4 14-3/4 4 11 54-1/2 1 320 0.53 $257
100 RHG PRO100-75 75 69 75.8 69.7 135 135 68 64 26-1/4 14-3/4 4 11 58 1 350 0.48 $284
100 RHG PRO100-73N* 73 – 73.7 – 116 – 68 64 26-1/4 14-3/4 4 11 58 1 350 0.48 $284
TALL
TYPE
Exclusive Professional Installation WarrantyWhen this Rheem PROFESSIONAL water heater is installed by a licensedcontractor, the consumer can upgrade his limited tank and parts warranty from6 to 8 years by returning to Rheem the warranty registration card and a copyof the contractor’s invoice.
This Rheem exclusive warranty upgrade feature enhances your value as aplumbing professional. A professional installation is a better installation.
Refer to the warranty certificate enclosed with each heater for specific details.
Fury Now with the Guardian System™
Available in 30, 40, 50 Gallon Tall – 30 and 40 Gallon Short Models� 6-Year Limited Tank and Parts Warranty*� With ProtectionPlus™ the 6-Year Limited Tank Warranty Becomes 10 Years! SEE PAGE 44.
Guardian System™
• One-of-a-kind air/fuel shut-off device offers doubleprotection
• Maintenance free – no filter to clean• Standard replacement partsEnvironmentally Friendly Burner• Low NOx design for low nitrous oxide emissionsSelf-Cleaning• EverKleen™ patented system fights sediment build-up• Reduces fuel costs• Provides more hot waterEasy to Light• No matches requiredEnergy Efficient• More hot water at low operating cost Longer Life• Patented magnesium anode rod design incorporates a
special resistor that protects the tank from rust
High Altitude Compliant• All models are certified for applications up to 6,000
feet above sea level. Some models are certified up to10,200 feet above sea level. Check factory for listing
Plus…• Brass drain valve and temperature and pressure relief
valve are included• Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirementsHE HIGH EFFICIENCY MODELS FEATURE:
• High performance and lower operating cost• Compliant with many gas utility incentive programs
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas 91¢/therm; LP $1.23/gallon.
Get4 MORE YEARSwith ProtectionPlus™
®
11
Rheem Guardian System Features…Exclusive Combustion Shut-off SystemShould a spill incident occur, the Guardian System shutsoff the gas supply and the air supply preventing a sus-tained vapor burn in the combustion chamber.
Flame Arrestor PlateA specially-designed flame arrestor prevents ignition ofvapors outside the combustion chamber.
Maintenance FreeSuperior air filtration prevents the flame arrestor frombecoming clogged by lint, dust and oil.
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: 42VR40-40PF.• For SCAQMD rule 1121 compliance models (California only), add “SQ” suffix to the model number. Example: 42VR40-40FSQ.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO WATER HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. HT. TO TANK GAS VENT CONN. SIDE WATER WT. FACTOR OPER. COSTCAP. MODEL NUMBER NAT. LP NAT. LP NAT. VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. (LBS) NAT. NAT.
40 42VR40-40F 40 34 40.4 34.3 68 63-1/4 59-3/4 21 14-1/2 3 8 53-1/2 3/4 135 0.62 $220
50 42VR50-40F 40 36 40.4 36.4 83 62-1/4 58-3/4 23 14-1/2 3 8 52-1/2 3/4 165 0.62 $220
29 22V30F 32 30 32.3 30.3 50 59-3/4 56-3/8 16-1/8 14-1/2 3 8 50-3/4 3/4 100 0.62 $220
40 22V40-36F1 36 – 36.4 – 67 61-1/2 58 17-3/4 14-1/2 3 8 53 3/4 120 0.59 $231
40 22V40F1 38 – 38.4 – 73 61-3/4 58-3/8 18-1/8 14-1/2 3 8 52-1/4 3/4 120 0.59 $231
38 42V40F 40 34 40.4 34.3 68 61-1/2 57-3/4 19-3/4 14-1/2 3 8 52-1/4 3/4 125 0.60 $227
50 22V50F1 38 – 38.4 – 90 61-1/2 58-1/4 20-1/8 14-1/2 3 8 51-3/8 3/4 130 0.58 $235
50 42V50-40F 40 36 40.4 36.4 83 61-1/2 58 21-3/4 14-1/2 3 8 52-1/2 3/4 150 0.58 $235
50 42V50-50F 50 – 50.5 – 83 62 58 21-3/4 14-1/2 4 8 52-1/2 3/4 150 0.58 $235
30 22V30S-30F 30 – 30.3 – 50 49-3/4 46-1/4 19-3/4 14-1/2 3 8 40-1/4 3/4 98 0.61 $224
40 22V40SF 36 34 36.4 34.3 72 52-3/4 49-3/8 20-1/8 14-1/2 3 8 42-3/4 3/4 130 0.59 $231
40 42V40SF 40 36 40.4 36.4 72 53-7/8 50-1/2 20-1/8 14-1/2 3 8 44 3/4 130 0.59 $231
50 42V50SF 40 36 40.4 36.4 84 54-1/4 49-3/4 22-1/4 14-1/2 3 8 44 3/4 158 0.59 $231
TYPE
TALL
HE TALL
SHORT
Fury Heavy Duty Gas Water Heaters
Available in 60, 75 and 100 Gallon Tall Gas Models� 6-Year Limited Tank and Parts Warranty*� With ProtectionPlus™ the 6-Year Limited Tank Warranty Becomes 10 Years! SEE PAGE 44.
• Designed for high volume applications• High BTU input for fast recovery• Extra durable brass drain valve• Heat saving flue baffle design• Temperature and pressure relief valve
included• Extra durable high temperature dip tube to
meet the most stringent plumbing codes
• Meets or exceeds National ApplianceEnergy Conservation Act (NAECA)requirements
* See Residential Warranty Information Brochure for complete warranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate natural gas 91¢/therm; LP $1.23/gallon.
Get4 MORE YEARSwith ProtectionPlus™
®
13
* SCAQMD rule 1121 compliance models.• Specify LP gas when ordering. Add “P” suffix to the model number: Example: 21V100P.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO WATER HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. HT. TO TANK GAS VENT CONN. SIDE WATER WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT. LP NAT. LP NAT. LP VENT HT. DIAM. CONN. SIZE CNTR. T&P CONN. (LBS) NAT. NAT.
60 42V60-50NT* 50 50 50.5 50.5 107 107 60 56 23 13-1/4 4 8 48-1/2 3/4 180 0.56 $244
75 22VR75-70N* 70 69 70.7 69.7 109 109 64-1/2 60-1/2 26-1/4 14-3/4 4 11 54-1/2 1 320 0.53 $257
100 21V100 75 69 75.8 69.7 135 135 68 64 26-1/4 14-3/4 4 11 58 1 350 0.48 $284
100 21V100N* 73 – 73.7 – 116 – 68 64 26-1/4 14-3/4 4 11 58 1 350 0.48 $284
TALL
TYPE
PowerVent Induced Draft Gas Water Heater with the Guardian System™
Available in 40 and 50 Gallon Models� 6-Year Limited Tank and Parts Warranty*� With ProtectionPlus™ the 6-Year Limited Tank Warranty Becomes 10 Years!** SEE PG. 44.
Guardian System™
• Air / fuel shut-off system offers double protection• Maintenance free –no filter to clean
Flammable Vapor Detection Sensor• Protective control system that disables the heater
in the presence of flammable vapor accumulation
Flexible Venting Options• Long venting lengths up to 100 feet• PVC, ABS, or CPVC vent pipe options• Vertical or horizontal termination
Plus…• New Quiet Blower• Self-Diagnostic System• Environmentally Friendly Low NOx Burner• High Altitude Compliant – Tall models are certified
for applications up to 7,700 feet and short modelsup to 6,000 feet
• Self-Cleaning – EverKleen™ patented system fightssediment build-up
• Reduces fuel costs and provides more hot water• Patented magnesium anode rod design
incorporates a special resistor that protects thetank from corrosion for longer life
• Electronic ignition system• Standard 110 volt electrical connection• Exceeds National Appliance Energy Conservation
Act (NAECA) and ASHRAE requirements* See Residential Warranty Information Brochure for complete
warranty information.
Energy Factor and Average Annual Operating Costs based on D.O.E.(Department of Energy) test procedures. D.O.E. national average fuel rate natural gas 91¢/therm;LP $1.23/gallon.
Get4 MORE YEARSwith ProtectionPlus™
®
15
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO HT. TO WATER HT. TO WATER SHIP. ENERGY AVG. ANN.GAL. MODEL THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. TOP OF TANK GAS CONN. SIDE T&P CONN. WT. FACTOR OPER. COSTSCAP. NUMBER NAT. LP NAT. LP NAT. ASSEMBLY HT. DIAM. CONN. CNTR. VALVE SIZE (LBS) NAT. NAT. GAS
40 42VP40F 40 40 40.4 40.4 68 69-1/4 59 19-3/4 14 8 53-1/2 3/4 140 0.64 $213
50 42VP50F 42 42 42.4 42.4 87 68-1/4 58 21-3/4 14 8 52-1/2 3/4 170 0.64 $213
40 42VP40SF 36 34 36.4 34.3 71 61-1/2 50-1/2 20-1/4 14 8 44 3/4 152 0.64 $213
50 42VP50SF 36 34 36.4 34.3 85 61-1/2 50-1/2 22-1/4 14 8 44 3/4 176 0.62 $220
TYPE
TALL
SHORT
• Specify LP gas when ordering. Add “PF” suffix to the model number. Example 42VP40PF.
VENTING INFORMATION FOR 2" VENTSNUMBER OF MINIMUM MAXIMUM90° ELBOWS NUMBER PIPE PIPE WITH VENT OF 45° LENGTH LENGTHTERMINAL ELBOWS REQ. (FT.) (FT.)
One (1) None 4.0 44.0
One (1) One (1) 4.0 41.0
Two (2) None 4.0 38.0
Two (2) One (1) 4.0 35.0
Three (3) None 4.0 32.0
For the 2" vent, one 90° elbow is approximately equal to6 feet of pipe. One 45° elbow is approximately equal to 3 feet of pipe.
VENTING INFORMATION FOR 3" VENTSNUMBER OF MINIMUM MAXIMUM90° ELBOWS NUMBER PIPE PIPE WITH VENT OF 45° LENGTH LENGTHTERMINAL ELBOWS REQ. (FT.) (FT.)
One (1) None 5.0 95.0
One (1) One (1) 5.0 92.5
Two (2) None 5.0 90.0
Two (2) One (1) 5.0 87.5
Three (3) None 5.0 85.0
Three (3) One (1) 5.0 82.5
Four (4) None 5.0 80.0
Four (4) One (1) 5.0 77.5
Five (5) None 5.0 75.0
For the 3" vent,one 90° elbow isapproximatelyequal to 5 feet ofpipe. One 45°elbow is approxi-mately equal to 2.5 feet of pipe.
PowerVent High Efficiency, Induced Draft Gas Water Heater
Available in 75 Gallon Model� 6-Year Limited Tank and Parts Warranty*
• Flexible venting options available in PVC, ABC and CPVC, see chart below
• Rated for installations up to 7,700 feet• Electronic ignition system• Allows vertical or horizontal
termination• NEW! Quiet blower operation• Heat traps included• T&P valve provided• Brass drain valve• Natural gas models meet low NOx
requirements
• Standard 110 volt electricalconnection
• Exceeds National Appliance EnergyConservation Act (NAECA) andASHRAE requirements
Energy Factor and Average AnnualOperating Costs based on D.O.E.(Department of Energy) test procedures.D.O.E. national average fuel rate naturalgas 91¢/therm; LP $1.23/gallon.
®
Integrated self-diagnosticsystem control, thermostat and gas valve
* See Residential Warranty Information Brochure for complete warranty information.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO HT. TO WATER HT. TO WATER SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. TOP OF TANK GAS CONN. SIDE T&P CONN. WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT. LP NAT. LP NAT. LP ASSEMBLY HT. DIAM. CONN. CNTR. VALVE SIZE (LBS) NAT. NAT.
75 22VRP75 75 75 75.8 75.8 130 130 69-1/2 60-1/2 26-1/4 14-3/4 11 54-1/2 1 325 0.53 $257
• Specify LP gas when ordering. Add “P” suffix to the model number; Example 22VRP75-P.
TYPE
TALL
75 GALLON MODEL MAXIMUM AND MINIMUM VENT LENGTHSSEA LEVEL (0-2,000 FT.): 3" VENT*
NUMBER OF MINIMUM MAXIMUM90° ELBOWS NUMBER PIPE PIPE WITH VENT OF 45° LENGTH LENGTHTERMINAL ELBOWS REQ. (FT.) (FT.)One (1) None – 40.00
One (1) One (1) 5.00 37.50
Two (2) None – 35.00
Two (2) One (1) – 32.50
Three (3) None – 30.00
HIGH ALTITUDE (2,000-7,700 FT.): 3" VENT*
NUMBER OF MINIMUM MAXIMUM90° ELBOWS NUMBER PIPE PIPE WITH VENT OF 45° LENGTH LENGTHTERMINAL ELBOWS REQ. (FT.) (FT.)One (1) None – 35.00
One (1) One (1) 5.00 32.50
Two (2) None – 30.00
Two (2) One (1) – 27.50
Three (3) None – 25.00
Three (3) One (1) – 22.50
* For the 3" and 4" vent, one 90° elbow is approximately equal to 5 feet of pipe. One 45° elbow is approximately equal to 2.5 feet of pipe.
SEA LEVEL TO HIGH ALTITUDE (0-7,700 FT.): 4" VENT*
NUMBER OF MINIMUM MAXIMUM90° ELBOWS NUMBER PIPE PIPE WITH VENT OF 45° LENGTH LENGTHTERMINAL ELBOWS REQ. (FT.) (FT.)One (1) None – 55.00
One (1) One (1) 5.00 52.50
Two (2) None – 50.00
Two (2) One (1) – 47.50
Three (3) None – 45.00
Three (3) One (1) – 42.50
17
Fury DV Rheemglas® Energy Miser® Direct Vent Gas Water Heater
Available in 40 and 50 Gallon Models� 6-Year Limited Tank and Parts Warranty*� With ProtectionPlus™ the 6-Year Limited Tank Warranty Becomes 10 Years! SEE PG. 44.
• Adjustable coaxial vent allows flexibilityof installation – uses outside air forcombustion and requires no electricalpower
• Aluminum vent and cap base to preventstaining of building exterior
• Heat saving flue baffle design• Brass drain valve• Temperature and pressure relief valve
included• Exclusive Rheemglas® tank lining
resists corrosion and prolongs tank life• Gas control and combination thermostat
• Anode rod equalizes aggressive wateraction
• Relief valve opening – side connect forfast economical installation
• Durable plastic formula dip tube• Meets or exceeds National Appliance
Energy Conservation Act (NAECA) requirements
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average Annual Operating Costs based on D.O.E.(Department of Energy) test procedures.D.O.E. national average fuel rate natural gas 91¢/therm; LP $1.23/gallon.
NEW LONGER VENTING**
Get4 MORE YEARSwith ProtectionPlus™
®
19
GE
AB
C
F
D
H
10"
3/4" N.P.T.RELIEF VALVE
OPENING
2"
1/2"
24-3/4"
EXTERIORWALL
(H: REAR VENTINGRANGE OF ADJUSTMENT)
(G: SIDE VENTINGRANGE OF ADJUSTMENT)
**NEW LONGER VENTING!Up to 4 feet above the water heater and 4 feet froman outside wall with 22DV50-38 and 22DV40S-36N.Water heater equipped for venting up to 4 feet horiz.Optional venting up to 4 feet vertical – order kit#SP20061.
HOT WATERCONNECTION
COLD WATERCONNECTION
UPPER INLETBOX ASSEMBLY
DESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK HT. TO VENT HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. VENT HT. DIAMETER GAS CONN. SIZE SIDE T&P WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT. NAT. NAT. A B C D E F (LBS) NAT. NAT.
50 22DV50-40N* 40 40.4 85 68 57-1/4 21-3/4 14-1/4 5 51-1/4 164 0.58 $235
50 22DV50-38 38 38.4 85 72-107† 57-1/4 21-3/4 14-1/4 6 51-1/4 164 0.58 $235
40 22DV40S-36N* 36 36.4 65 63-98† 48-1/4 21-3/4 14-1/4 6 43 152 0.59 $231
TALL
TYPE
* For SCAQMD rule 1121 compliance.† With vertical Vent Kit #SP20061. Venting dimensions are approximate.• If side wall is combustible material, 1" clearance must be included in adjustment range.NOTE: Maximum adjustment range for vent system is 10" for 22DV50-40N;40" for 22DV40S-36N and 22DV50-38. Review installation manual before installation.
SHORT
Rheem Exclusive Adjustable Coaxial Vent Allows Flexibility of Installation…You may orient the Fury DV for easiest service access, because the adjustable coaxial vent can swivel 360 degrees.
TALL 22DV50-40N N/A 8-1/8 18-1/8 3-1/8 13-1/8 N/A
TALL 22DV50-38 Horizontal 8-1/8 48 3-1/8 43 72-107†
SHORT 22DV40S-36N & Vertical 8-1/8 48 3-1/8 43 63-98†
VENTING – ROUGHING IN DIMENSIONS (INCHES)
MODEL 4 FEET VENTING SIDE VENTING (G) REAR VENTING (H) OPTIONAL HEIGHT (A)TYPE NUMBER AVAILABLE MIN. MAX. MIN. MAX. WITH VENT KIT #SP20061
Warrior Gas Water Heater Specifically Designed for Manufactured Housing
Available in 30 and 40 Gallon Models� 5-Year Limited Tank Warranty* � 1-Year Limited Parts Warranty*
• Optional air inlet and leg enclosure allowsoutside air to be supplied to the waterheater without exposing the home to cold air
• Two hole top for anode rod and hot wateroutlet
• Factory installed temperature and pressurerelief valve – side location
• Exclusive Rheemglas® tank lining resistscorrosion and prolongs tank life
• Anode rod equalizes aggressive wateraction
• Piezo ignitor – easy light pilot• Field convertable controls for natural gas
or LP operation
• Meets or exceeds National ApplianceEnergy Conservation Act (NAECA)requirements
• Anode rod equalizes aggressive wateraction
• Cold water inlet – side connection allowsfor quick, economical hook-up
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate natural gas 91¢/therm; LP $1.23/gallon.
®
21
The Warrior is CSA certified for manufacturedhome use, meets ANSI Standards for modularhome construction and complies with HUD safetyand construction standards.
Draft DiverterNew improved designprovides efficient heatingwith down-draftprotection.
Optional Air Inlet and Leg EnclosureGalvanized wrap-aroundleg enclosure and metaltabular air inlet areaffixed to the base. Inletis equipped with a 1/2"screen for protectionagainst rodents.
PART NUMBERS
30 Gallon 40 Gallon
Air Inlet AP11596 AP11596
Leg Enclosure AE24609C AE24609D
DESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO TANK WATER HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. DIAM. VENT HT. VENT CONN. SIDE WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT. NAT. NAT. (IN.) (IN.) (IN.) SIZE CNTR. T&P (LBS) NAT. NAT.
30 21VR30T 34 34.3 49 17-3/4 60-1/4 57 3 8 51-1/2 110 0.61 $224
40 21VR40T 34 34.3 64 19-3/4 60-3/4 57-1/2 3 8 51-1/2 125 0.59 $231TALL
TYPE
Warrior DVThe Direct Vent Gas Water Heater for Manufactured Housing
Available in 30, 40 and 50 Gallon Models� 5-Year Limited Tank Warranty* � 1-Year Limited Parts Warranty*
• No external vented door is required• All combustion air comes from outside the
home• Provides maximum design freedom since it
can be placed anywhere within the home• Hot water outlet located at top• Factory installed temperature and pressure
relief valve – side location.• Exclusive Rheemglas® tank lining resists
corrosion and prolongs tank life• Field convertable controls for natural gas or
LP operation• Meets or exceeds National Appliance
Energy Conservation Act (NAECA)requirements
• Piezo ignitor – easy light pilot• Certified for manufactured (HUD) and
modular construction• Anode rod equalizes aggressive water
action• Cold water inlet – side connection allows
for fast, economical hook-up
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate natural gas 91¢/therm; LP $1.23¢/gallon. UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
23
THE WARRIOR DV IS U.L. CERTIFIED FOR MANUFACTURED HOME USE,MEETS ANSI STANDARDS FOR MODULAR HOME CONSTRUCTION, ANDCOMPLIES WITH HUD SAFETY AND CONSTRUCTION STANDARDS.
Adjustable Roof Jack VentNew design allowsadjustment to roof pitches of up to 5/12". Four roofjacks available toaccommodate roofthickness of 12" up to 95".
Direct Combustion Air InletAir is drawn directly intocombustion chamberthrough air inlet fixed tobase; 1/2" screen for rodent protection.
30 21VR30DV 30 30.3 51 57 57 17-3/4 14-1/2 3 5 51-1/2 20 110 0.61 $224 $331
40 21VR40DV 30 30.3 60 57-1/2 57-1/2 19-3/4 14-1/2 3 5 51-1/2 20 125 0.59 $231 $342
50 21VR50DV 32 32.3 67 57 57 21-3/4 14-1/2 3 5 51-1/2 20 150 0.58 $235 $348
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
GAS INPUT IN RECOVERY IN FIRST HOUR HT. TO ROOF HT. TO SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. HT. TO TANK GAS VENT JACK SIDE WATER WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT/ LP NAT./LP NAT./ LP VENT HT. DIAM. CONN. SIZE VENT SZ. T&P CONN. (LBS) NAT./LP NAT. LP
TYPE
TALL
ROOF JACKS12" Non Adjustable & Air Inlet AP12032E15-32" Adjustable & Air Inlet AP12032B30-60" Adjustable & Air Inlet AP12032C48-95" Adjustable & Air Inlet AP12032D
AIR INLETS6" Non Adjustable AP12019B11-22" Adjustable AP12017B
EXTENSION PIPE KITRoof Jack Extension Pipe Kit AP12021
• Roof jack and air inlet mustbe ordered separately with30, 40 and 50 gallon directvent models and must be inaccordance with instructionsfurnished with the heater. Noother roof jack or air inletassemblies are approved forinstallation with this heater.Clamps and secure strappingare packed in water heatercarton.
Warrior DVX The Vertical Co-Axial Direct Vent Gas Water Heater for Manufactured Housing
Available in 40 and 50 Gallon Models� 5-Year Limited Tank Warranty* � 1-Year Limited Parts Warranty*
• Installed side mounted T&P valve• No external vented door required• Can be placed anywhere in the home• Field convertible controls for natural gas
or LP operation• 3/4" top connections for hot and cold• Meets or exceeds National Appliance
Energy Conservation Act (NAECA)requirements
• Venting system eliminates the need to cut a hole in the floor
• Piezo ignitor – easy light pilot
• Certified for manufactured (HUD) andmodular construction
* See Residential Warranty Information Brochure for complete warranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate natural gas 91¢/therm; LP $1.23¢/gallon.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
50 22V50DVX 38 38.4 67 21-3/4 57 5 3/4 164 0.58 $235 $348
40 22V40SDVX 36 36.4 62 21-3/4 48-1/4 5 3/4 152 0.59 $231 $342
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATIONTANK VENT
GAS INPUT IN RECOVERY IN FIRST HOUR DIAM. HEIGHT SIZE SHIP. ENERGY AVG. ANN.GAL. THOUS. BTU/HR. G.P.H. 90° RISE DEL. G.P.H. WATER WT. FACTOR OPER. COSTSCAP. MODEL NUMBER NAT/ LP NAT./LP NAT./ LP A B C CONNECTION (LBS) NAT./LP NAT. LP
TYPE
TALL
SHORT
A
B
C
SEE CHARTFOR ROOF
JACKS
25
ROOF JACK VERTICAL VENT KITS24-37" Adjustable AP13335A33-68" Adjustable AP13335B45-97" Adjustable AP13335C55-132" Adjustable AP13335D65-164" Adjustable AP13335E
Roof Jacks must be ordered separatelywith this direct vent water heater andinstalled in accordance with the instructionsfurnished with the heater. No other roofjack or vertical vent kit is approved forinstallation with this heater.
HOT WATERCONNECTION
COLD WATERCONNECTION
UPPER INLETBOX ASSEMBLY
29-1/4"
THE WARRIOR DVX IS ANSI AND U.L. CERTIFIED FOR USE INMODULAR HOME CONSTRUCTION AND MANUFACTUREDHOME USE. THIS UNIT COMPLIES WITH HUD SAFETY ANDCONSTRUCTION STANDARDS.
Professional™Sold and Installed Only by Plumbing Professionals
Available in 30, 40, 50, 65 and 80 Gallon Electric Models� 8-Year* Limited Tank and Parts Warranty with a Professional Installation.� With ProtectionPlus™ the 8-Year Limited Tank Warranty Becomes 12 Years! SEE PAGE 44.
• Brass drain valve• Stainless steel lower heating element• EverKleen™ self cleaning device• Premium grade anode rod• Temperature and pressure relief valve included• Exclusive Rheemglas® tank lining resists
corrosion and prolongs tank life• Isolated tank design reduces conductive heat
loss• Electric junction box located above heating
elements for easy installation• Over-temperature protector cuts off power in
excess temperature situations• Automatic thermostat keeps water at desired
temperature
• Compliant with many electric utility incentiveprograms
• Meets or exceeds National Appliance EnergyConservation Act (NAECA) and C.E.C.requirements
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate electricity 8.6¢/KWH.
Get4 MORE YEARSwith ProtectionPlus™
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
27
DESCRIPTION FEATURES DIMENSIONS ENERGY INFORMATION
RECOVERY APPROX. AVERAGEGAL. FIRST HOUR IN G.P.H. HEIGHT HEIGHT TO DIAMETER SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER RATING G.P.H. @ 90° RISE (IN) WATER CONN. (IN.) (LBS.) FACTOR OPER. COST
40 RHE PRO40-2 56 21 46-3/4 46-3/4 22-1/4 104 0.94 $402
40 RHEH PRO40-2 57 21 59-1/4 59-1/4 17-3/4 96 0.92 $411
50 RHE PRO52-2 67 21 57 57 22-1/4 123 0.94 $402
65 RHE PRO66-2 71 21 58-3/4 58-3/4 23 160 0.92 $411
80 RHE PRO80-2 88 21 59 59 24-1/2 181 0.92 $411
30 RHEM PRO30-2 44 21 36 36 19-3/4 80 0.93 $406
50 RHEM PRO52-2 62 21 46 46 24-1/4 128 0.93 $406
30 RHES PRO30-2 42 21 30 30 22-1/4 83 0.93 $406
38 RHES PRO40-2 46 21 31-1/2 31-1/2 23 108 0.92 $411
47 RHES PRO50-2 55 21 32 32 26-1/4 149 0.91 $415
TALL
TYPE
• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements.• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.• Special Wiring Options – A limited number of special wiring options are available. Consult factory for price and availability.• All models equipped with heat traps.
SHORT
MED.
Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH2.42 x 90°
Marathon™…Shaping The Future
Available in 40, 50, 85 and 105 Gallon Electric Models� Lifetime Limited Tank Warranty* � 6-Year Limited Parts Warranty*
• Seamless, blow-molded, polybutylene tank– impervious to rust and corrosion
• Multiple layers of filament wound fiberglassgive the tank unmatched strength
• Polyurethane Envirofoam™ insulation helpsreduce energy consumption
• The highest energy factors (EF) available!• Pipe wrap energy saving kit included to
achieve maximum energy savings• Recessed drain valve is out of the way of
brooms and scrubbers• Tough molded polyethylene outer shell
resists dents and scratches• Bowl shaped bottom allows complete
sediment draining• High temperature polysulfone dip tubes
• Thermally fused upper element providesprotection against “dry-firing” – stainlesssteel incoloy lower element for resistance tolime build-up
• Factory installed conduit between elementcontrol boxes
• All plastic tank eliminates the need for ananode rod
• Factory installed temperature and pressurerelief valve
• Factory installed vacuum relief valve* See Residential Warranty Information Brochure for complete
warranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate electricity 8.6¢/KWH.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
29
DESCRIPTION FEATURES DIMENSIONS ENERGY INFORMATION
RECOVERY APPROX. AVERAGEGAL. FIRST HOUR IN G.P.H. HEIGHT HEIGHT TO DIAMETER SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER RATING G.P.H. @ 90° RISE (IN) WATER CONN. (IN.) (LBS.) FACTOR OPER. COST
40 MR40245 52 21 61-1/2 62-1/2 21-3/4 91 0.94 $402
50 MR50245 61 21 62-3/4 63-3/4 23-1/2 103 0.94 $402
85 MR85245 91 21 66-1/4 67-1/4 28-1/4 139 0.92 $411
105 MR105245 104 21 66-3/4 67-3/4 30-1/4 152 0.91 $415
SHORT 50 MSR50245 54 21 47-1/4 48-1/4 28-1/4 101 0.94 $402
TALL
TYPE
• 240 volt AC single phase standard• For height to top of T&P and heat traps add 3-1/2" to the height to
water connection.Maximum test pressure: 300 PSIMaximum working pressure: 150PSI
Your Marathon is warranted not to leak for aslong as you own your home*…The Marathon offers this no-leak promise because of its superior,non-metallic PermaGuard tank construction…A seamless blowmolded polybutylene inner tank with a filament wound fiberglassouter tank for maximum strength. Superior performance, high-efficiency and low operating cost…for a lifetime*!* See Residential Warranty Information Brochure at your dealer for complete warranty information.
Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH2.42 x 90°
Fury Rheemglas® Energy Miser® Electric Water Heater
Available in 30, 40, 50, 65, 80 and 120 Gallon Tall – 30 and 50 Gallon Medium – 20, 30, 38 and 47 Gallon Short Models� 6-Year Limited Tank and Parts Warranty*� With ProtectionPlus™ the 6-Year Limited Tank Warranty Becomes 10 Years! SEE PAGE 44.
• EverKleen™ self cleaning device• Brass drain valve• Temperature and pressure relief valve included• Isolated tank design reduces conductive heat loss• High efficiency resistored heating elements• Anode rod equalizes aggressive water action• Electric junction box located above heating
elements for easy installation• Over-temperature protector cuts off power in
excess temperature situations• Automatic thermostat keeps water at desired
temperature• Meets or exceeds requirements of the National
Appliance Energy Conservation Act (NAECA)
HE HIGH EFFICIENCY MODELS FEATURE:
• High performance and lower operating cost• Compliant with many electric utility
incentive programs
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate electricity 8.6¢/KWH.
Get4 MORE YEARSwith ProtectionPlus™
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
31
• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements.• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.• Single element models available on special order (6000W max.). Substitute “-1” for “-2” in model number.• Special Wiring Options – A limited number of special wiring options are available. Consult factory for price and availability.• All models equipped with heat traps.
Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH2.42 x 90°
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
RECOVERY APPROX. AVERAGEGAL. FIRST HOUR IN G.P.H. TANK HEIGHT TO SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER RATING G.P.H. @ 90° RISE HEIGHT WATER CONN. DIAMETER (LBS.) FACTOR OPER. COST
40 83VR40-2 56 21 46-3/4 46-3/4 22-1/4 104 0.94 $40250 83VR52-2 67 21 57 57 22-1/4 123 0.94 $40265 83VR66-2 71 21 58-3/4 58-3/4 23 160 0.92 $41180 83VR80-2 88 21 59 59 24-1/2 181 0.92 $41150 83MVR52-2 62 21 46 46 24-1/4 128 0.93 $40630 82V30-2 48 21 45-3/4 45-3/4 17-3/4 80 0.93 $40640 82V40-2 53 21 46-1/2 46-1/2 19-3/4 95 0.92 $41140 82VH40-2 57 21 59-1/4 59-1/4 17-3/4 96 0.92 $41150 82V52-2 58 21 57 57 19 107 0.91 $41565 82V66-2 71 21 58-1/2 58-1/2 21 150 0.89 $42580 82V80-2 88 21 59 59 23 177 0.86 $439
120 82V120-2 99 21 62-1/2 62-1/2 28-1/4 324 0.85 $44430 82MV30-2 44 21 36 36 19-3/4 80 0.93 $40650 82MV52-2 62 21 46 46 21-3/4 117 0.90 $42020 82SV20-2 – 21 31-1/2 31-1/2 17 62 N/A N/A30 82SV30-2 42 21 30 30 22-1/4 83 0.93 $40638 82SV40-2 45 21 31-1/2 31-1/2 23 108 0.92 $41147 82SV50-2 55 21 32 32 26-1/4 149 0.91 $415
TYPE
TALL
MED.
HE
TALL
MED.
SHORT
Warrior Rheemglas® Electric Water Heater for Manufactured Housing
Available in 20, 30, 40 and 50 Gallon Side Connect Models� 5-Year Limited Tank Warranty* � 1-Year Limited Parts Warranty*
• Lifeguard™ stainless steel element**• Isolated tank design reduces heat loss• High efficiency heating elements • Exclusive Rheemglas® tank lining resists
corrosion and prolongs tank life• Anode rod equalizes aggressive water action• Automatic temperature control thermostat• Over-temperature protector automatically
cuts off power in excess temperaturesituations
• Electrical junction box (for 1/2" and 3/4"conduit) placed above heating elementsfor easy installation
• Meets H.U.D. Safety and ConstructionStandards, ASHRAE 90A-80 andNational Appliance Energy ConservationAct (NAECA) requirements
Design evaluated in accordance with Part 3280.707(d)(1)or (2) of HUD Mobile Home Construction and SafetyStandards for Energy Efficiency.* See Residential Warranty Information Brochure for complete
warranty information.** Double element models upper element only.
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate electricity 8.6¢/KWH.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
33
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
FIRST HOUR RECOVERY IN G.P.H. APPROX. AVERAGEGAL. RATING G.P.H. @ 90° RISE TANK HEIGHT TO SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER 3500 WATTS 4500 WATTS 3500 WATTS 4500 WATTS HEIGHT WATER CONN. DIAMETER (LBS.) FACTOR OPER. COST
TALL
TYPE
SIDE CONNECT20 72V20-1 – – – – 31-1/2 25-1/2 17-3/4 62 N/A N/A
30 72V30-2 41 46 16 21 45-1/2 39-3/4 17-3/4 70 0.93 $406
40 72V40-2 47 51 16 21 46-3/4 40-1/4 19-3/4 94 0.92 $411
50 72V52-2 51 56 16 21 57 50-3/4 19-3/4 108 0.91 $415
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 3500 watt or 4500 watt heating elements. 71-20 furnished with standard 120
volt AC, single phase, 2000 watt heating element.• Special Wiring Options – A limited number of special wiring options are available. Consult factory for price and availability.• For single element, substitute “-1” suffix for “-2”.
Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH2.42 x 90°
Marathon™ Point-of-Use…With The All Plastic Tank That Can’t Corrode
• Seamless, blow-molded, polybutylenetank – impervious to rust and corrosion
• Multiple layers of filament wound fiber-glass give the tank unmatched strength
• Polyurethane Envirofoam™ insulationhelps reduce energy consumption
• The most energy efficient in its class• Recessed brass drain valve is out of the
way of brooms and scrubbers• Tough molded polyethylene outer shell
resists dents and scratches• Bowl shaped bottom allows complete
sediment draining• High temperature polysulfone dip tubes
• All plastic tank eliminates the need for ananode rod
• Thermally fused element to protect tankagainst “dry-fire”; low watt, density forlong life
• Factory installed temperature andpressure relief valve
• Factory installed vacuum relief valve• Inlet and outlet connections are 3/4" NPT• Water tight grommets keep out overhead
moisture and condensation
* See Residential Warranty Information Brochure for complete warranty information.
Available in 15 and 20 Gallon Electric Models� Residential Use: Lifetime Limited Tank Warranty, 6-Year Limited Parts Warranty* � Light Duty Commercial Use: 10-Year Limited Tank Warranty, 1-Year Limited Parts Warranty*
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
APPROX. AVERAGEGAL. ELEMENT TANK HEIGHT TO TANK SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER WATTAGE VOLTAGE HEIGHT WATER CONN. DIAMETER (LBS.) FACTOR OPER. COST
15 MR15120 2000 120 31-3/4 35-3/4 21-3/4 46 N/A N/A
20 MR20120 2000 120 30-1/2 34-1/2 23-3/4 51 N/A N/A
20 MR20230 3000 240 30-1/2 34-1/2 23-3/4 51 N/A N/A
Marathon Point-of-Use water heaters arebuilt to the same specifications as our full-size Marathons. These point-of-use waterheaters are great for applications where thelarger water heaters won’t fit, or for specialuses such as:
• Apartments and condo’s
• Restrooms in offices and commercialbuildings
• Cabins, camps and recreational property
• Lavatories in large homes away fromcentral water heating system
35
RESIDENTIAL USE
LIFETIME / 6 YEARS*Privately owned, single family dwellings – the tank is warranted not to leak “for as long as you own your home”. If the home is sold, the warranty reverts to fifteen years from the date of the installation and the second owner receivescoverage for the time remaining. Parts are warranted for 6 years from the date of manufacture or 5 years from the effective date, whichever is greater.
LIGHT DUTY COMMERCIAL USE
10 YEARS /1 YEAR*Apartments, condominiums, restrooms in office and commercial buildings,multifamily housing or any light duty commercial/industrial use – the tank iswarranted for 10 years from the date of installation. Parts are warranted for 1 year from the date of manufacture.
* See Marathon Point-of-Use Warranty Information Brochure at your dealer for completewarranty information.
The Marathon Point-of-Use Water Heater Warranty
Point-of-Use Rheemglas® Energy Miser® Electric Water Heaters
Available in 2-1/2, 6, 10, 15, 20 and 30 Gallon Models� 6-Year Limited Tank and Parts Warranty*
• Space-saving design for installation in limited spaces
• High efficiency heating element• Temperature and pressure relief valve
included• Over-temperature protector cuts off power
in excess temperature situations• Automatic thermostat keeps water at
desired temperature• Meets or exceeds National Appliance
Energy Conservation Act (NAECA)requirements
2-1/2 gallon model features:• 120 volt model with 3 prong cord set…
simply plug it in! 240 volt model includes ajunction box for easy installation of 1/2" or3/4" conduit
• Wall bracket for easy wall mount installations• Corrosion resistant 1/4 turn drain valve
* See Residential Warranty Information Brochure for completewarranty information.
2-1/2 Gallon
6, 10, 15, 20 and30 Gallon
Energy Factor and Average Annual OperatingCosts based on D.O.E. (Department of Energy)test procedures. D.O.E. national average fuelrate electricity 8.6¢/KWH.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
37
DESCRIPTION ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFORMATION
APPROX. AVERAGEGAL. HT. TO HOT HT. TO HT. TO COLD SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER HEIGHT WATER OUTLET DIAMETER SIDE T&P WATER INLET (LBS.) FACTOR OPER. COST
2.5 81VP2S 14 14 9-3/4 – – 22 N/A N/A
6 81VP6S 15-1/4 12-1/2 15-3/4 11-1/2 4-1/4 36 N/A N/A
10 81VP10S 23 20-1/2 15-3/4 19-1/2 4-1/4 46 N/A N/A
15 81VP15S 24-1/4 22 17-3/4 21 4-1/2 54 N/A N/A
20 81VP20S 25-1/4 22-3/4 19-3/4 21-3/4 5 69 N/A N/A
30 82VP30-1* 30 23 21-3/4 23 2-3/4 91 0.93 $406
* For double element, substitute “-2” suffix for “-1”. Not available in 120 volt. Available with 2-wire (single phase) outlet only. (6000 watt max.).
• 2.5 gallon model: 1⁄2" N.P.T. inlet and outlet. Relief valve connection 3⁄4".Available with 120 or 240 volt AC single phase only, 120v (1440w) 240v (1500w)Power cord supplied with 120 volt models only.Optional 14" diameter safety catch pan with 1" side drain outlet available (Part No. AS-21990A-G).
• 6 through 30 gallon models: 3⁄4" N.P.T. outlet, inlet, anode rod. T & P valve connections. Not available with 3 phase wiring.Water heaters furnished standard with 120 volt AC, 2000 watt single element.Special wiring options – a limited number of wiring options are available. Consult factory for price and availability.
CONSTRUCTION DETAILS: The cold water enters the tank a few inches from the bottom. Both hot and cold water lines may be connecteddirectly to the water heater without special nipples or tees. The relief valve simply screws into the opening provided.
Table Top Rheemglas® Energy Miser® Electric Water Heaters
Available in 40 Gallon Model� 6-Year Limited Tank and Parts Warranty*
• Brass drain valve• 36" high top features a four inch high
integral back splash• Baked enamel top is acid and heat
resistant• High efficiency screw-in type heating
elements• Temperature and pressure relief valve
included• Recessed base and channel in back
panel permit water heater to fit snuglyagainst wall
• Cold water inlet, hot water outlet, reliefvalve and electrical connections at topof tank for easy access and fasteconomical installation
• Rheemglas® tank lining resistscorrosion and prolongs tank life
• Direct immersion resistored heatingelements are completely immersed -all the heat goes into the water
• Extra thick fiberglass insulation• Automatic thermostat keeps water at
desired temperature• Meets or exceeds National Appliance
Energy Conservation Act (NAECA)requirements
* See Residential Warranty Information Brochure for completewarranty information.
Energy Factor and Average AnnualOperating Costs based on D.O.E.(Department of Energy) test procedures. D.O.E. national averagefuel rate electricity 8.6¢/KWH.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
39
DESCRIPTION FEATURES DIMENSIONS ENERGY INFORMATION
RECOVERY APPROX. AVERAGEGAL. FIRST HOUR IN G.P.H. WIDTH HEIGHT HEIGHT TO SHIP WT. ENERGY ANNUALCAP. MODEL NUMBER RATING G.P.H. @ 90° RISE (IN.) (IN) WATER CONN. (LBS.) FACTOR OPER. COST
40 88H-40D 45 21 25 36 33 156 0.88 $429
TYPE
• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 watt upper and lower heating elements.• If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested.• Special Wiring Options – A limited number of special wiring options are available. Consult factory for price and availability.
Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH2.42 x 90°
Solaraide™Storage Tank and Electric Storage Water Heaters for Solar Applications
Available in 80 and 120 Gallon Side Connect and Top Connect Models� 6-Year Limited Tank and Parts Warranty*
• Brass drain valve• Choice of two models…storage tank or
single element water heater, both speciallyequipped for installation with residentialdirect solar systems
• Special threaded stud located near theoutlet for attachment of tank sensors
• Temperature and pressure relief valveincluded
• Collector feed and return fittings located atfront of tank for convenient installation
• Isolated tank design for better heat retention
• High efficiency heating element• Rheemglas® tank lining resists corrosion
and prolongs tank life
• Cold water inlet brings cold water to tank bottom to prevent mixing with heated water
• Anode rod equalizes aggressive wateraction for prolonged tank life
• Cold water inlet, hot water outlet, reliefvalve and anode rod at top of tank foreasy access and fast, economicalinstallation
• Automatic temperature control• Over temperature protector* See Residential Warranty Information Brochure for complete
warranty information.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
41
DESCRIPTION DIMENSIONS ENERGY INFORMATION
MAXIMUM HEIGHT HEIGHT APPROX. APPROX.GAL. WATTAGE DIAMETER HEIGHT TO COLLECTOR TO COLLECTOR SHIP WT. R-CAP. MODEL NUMBER UPPER (IN.) (IN) FEED (IN) RETURN (IN) (LBS.) FACTOR
TALL
TYPE
• All units furnished standard 240 volt AC.• Units are shipped with a 4500 watt
element. If heating elements of differ-ent wattages than those shown aredemanded by zone requirements,they must be specifically requested.
• Solaraide models meet all currentrequirements for solar storage tanks.
• The tanks are Rheemglas lined and aredesigned to operate up to 150 PSI.
SIDE CONNECT
80 81VR80-1 6000 W 24-1/2 58-3/4 7 37 192 R-17.3
120 81VR120-1 6000 W 28-1/4 62 7 37 336 R-16.7
80 81VR80-T Storage Only 24-1/2 58-3/4 7 37 192 R-17.3
120 81VR120-T Storage Only 28-1/4 62 7 37 336 R-16.7
TOP CONNECT
80 81VR80TC-1 6000 W 24-1/2 58-3/4 – – 192 R-17.3
120 81VR120TC-1 6000 W 28-1/4 62 – – 336 R-16.7
80 81VR80TC-T Storage Only 24-1/2 58-3/4 – – 192 R-17.3
120 81VR120TC-T Storage Only 28-1/4 62 – – 336 R-16.7
TALL
SIDE CONNECTRaised 7" from the bottom, theoutlet to the solar collector panelhelps prevent scale andsediment from entering thecirculating through the solarsystem.
A special threaded stud is also welded to the tank nearthe outlet for attachment of tank sensors.
TOP CONNECTA special threaded stud is alsowelded to the tank behind thelower cavity opening. Low voltagesensor wire is run from this pointinside the jacket and out the topfor easy control connection.
Solaraide™ HE Solar Heat Exchanger, Solar Tank, or Electric Storage Water Heater
Available in 80 Gallon Models� 6-Year Limited Tank and Parts Warranty*
• Brass drain valve• Choice of two models…storage tank or
single element water heater, both speciallyequipped for installation with residentialdirect solar systems
• Temperature and pressure relief valveincluded
• Collector feed and return fittings located atfront of tank for convenient installation
• Isolated tank design for better heat retention
• High efficiency heating element• Rheemglas® tank lining resists corrosion
and prolongs tank life
• Cold water inlet brings cold water to tankbottom to prevent mixing with heatedwater
• Anode rod equalizes aggressive wateraction for prolonged tank life
• Cold water inlet, hot water outlet, reliefvalve and anode rod at top of tank foreasy access and fast, economicalinstallation
• Automatic temperature control• Over temperature protector* See Residential Warranty Information Brochure for complete
warranty information.
UL
AN
INDEPENDENT LABORATO
RY
TE
STING FOR PUBLICSAFET
Y®
®
43
• Heaters furnished standard 240 volt AC.• Units are shipped with a 4500 watt element. If heating elements of different
wattages than those shown are demanded by zone requirements, they mustbe specifically requested.
• To prevent corrosion, proper pH levels in transfer fluid must be maintained.• Solaraide models meet all current state requirements for solar storage tanks.• The tanks are Rheemglas lined and are designed to operate up to 150 PSI.
A special 1/2" NPT opening is provided for installation of a “probe type” thermostat.
COPPER COIL DATA (Type L Copper)Maximum pressure = 150 psi
Maximum temperature = 185°F.Tube I.D. = 5/8"
Solaraide HE Coil Capacity Length of TubingTank Capacity Gallons Around Tank (Ft)
80 Gallons 2.2 120
PRESSURE DROP THROUGH COIL (Feet of H20)Head Loss (Feet)
Flow Rate 80 Gallon1 GPM 1.32 GPM 4.83 GPM 10.0
DESCRIPTION DIMENSIONS ENERGY INFORMATION
MAXIMUM HEIGHT HEIGHT APPROX. APPROX.GAL. WATTAGE DIAMETER HEIGHT TO COLLECTOR TO COLLECTOR SHIP WT. R-CAP. MODEL NUMBER UPPER (IN.) (IN) FEED (IN) RETURN (IN) (LBS.) FACTOR
TALL
TYPE
80 81V80HE-1 6000 W 24-1/2 58-3/4 6 30 192 R-17.3
80 81V80HE-T Storage only 24-1/2 58-3/4 6 30 192 R-17.3
44
ProtectionPlus™4 Year Limited Warranty Extension Kit
The best water heater warranty in the industry comes in the smallest box!Part Number: SP20079 (Sold only in 6 package quantity)
� For use on Rheem® Residential Fury, Professional, PowerVent and Direct Vent models*
• Kit contains:� High quality magnesium anode rod with plastic lined nipple (hot side)� Plastic lined nipple (cold side)� Warranty certificate with installation instructions� ProtectionPlus™ label for heater
• Provides up to 135% additional anodic protection• With just two water heaters, you have the option of
selling four warranty periods• Effectively have four water heaters in little more
space than two
* Not for use on: Warrior, Warrior DV, Marathon, Point-of-Use, or Table Top models.
6 Y E A R L I M I T E DT A N K W A R R A N T Y
BECOMES 108 Y E A R L I M I T E D
T A N K W A R R A N T Y
BECOMES 12
Lifeguard™ Electric Element
45
Designed for the future, the LIFEGUARD™ electric water heaterelement is as close to a lifetime element as space-age technology can produce*.
Patented resistor design** helps prolong anode rod and tank life…A Rheem Exclusive!* See Residential Warranty Information Brochure for complete warranty information.** Registered trade-mark of International Nickel Co.
Steel screw-in headprovides solid constructionand ease of maintenance.
INCOLOY® 840 stainless steel sheath,resists water chemical corrosion andburn-out even in air or sediment forlong element life, long life performance.
High-grade magnesium oxidepacking moves the heatquickly to the element’ssurface, protecting thenichrome wire filament andboosting efficiency.
High density nichrome wire electricheating filament; best grade A, 80/20nichrome wire made…for topperformance and long-life operation.
Low watt density design deliversfull watt-rated heating power to alarger surface area, eliminatinghigh heat concentrations andprolonging element life.
46
EverKleen™
• Fights Sediment Build-Up• Helps Preserve Operating Efficiency• Helps Improve Tank Life• Provides Increased DeliverabilitySediment build-up in a water heater creates layers of non-conducting material between thewater and the energy that heats the water. This causes a reduction of heat transfer whichincreases tank bottom temperatures and decreases water temperatures. When this occurs,the results are decreased water heater efficiency and decreased tank life.
The EverKleen™ system helps to dislodge this sediment by channeling water through a specially developed inlet tube. This tubecreates a high-velocity spiraling water stream which strikes the bottom of the water heater tank with sediment “busting” force.
The spiraling effect also creates better mixing throughout the water heater tank which reduces the effects of stacking. Stackingoccurs when frequent small draws of water create different temperatures throughout the tank resulting in increased peaktemperatures at the top of the tank. The EverKleen™ system greatly reduces peak temperatures, thus increases first hourdeliverability.
Included at no extra charge on all Rheem Fury and Professional™ models.
CATCH PAN KITAvailable in 5 sizes to help protect any installation areafrom possible water damage. Each 2" deep drain pan ismanufactured of aluminum and fitted with a 1" drain outlet.Provides that extra level of “protection assurance” thatmany homeowners and apartment dwellers are looking for.Available in 18", 20", 22", 24",and 261⁄2" diameters. Ourspecially designed,tapered side wallallows for “one-inside-the-other”stacking andminimal storagearea. Available withside drain outlet.
WALL MOUNTING KITFor Point-of-Use Electric Water Heaters
This wall mounting kit for point-of-use electric waterheater installations provides an easy way to mount the
unit off the floor, out of theway for more usable floorspace in a small area. It’sbeen designed for use with 6, 10, 15, and 20 gallonmodels (AS-36111) and allwalls with 16" stud centers.All necessary parts areincluded in this easy to install,time-and-money saving kit.
Accessories
Catch pan must conformto local codes.
47
48
Eliminates problems associatedwith thermal expansion in closedloop systems.• 5 year limited tank warranty• Suitable for water heaters up to
120 gallon capacity and supplypressure to 80 PSI.
Maximum Operating ConditionsOperating Working
Temperature Pressure (PSIG)200°F (93°C) 150 (10.5 kg/cm2)200°F (93°C) 150 (10.5 kg/cm2)200°F (93°C) 150 (10.5 kg/cm2)
(Vt) TotalVolume
(Gallons)2.04.410.3
Diameter(A)08"11"
153⁄8"
Height(B)
125⁄8"15"
151⁄4"
SystemConnection
3⁄4" NPTM – BRASS3⁄4" NPTM – BRASS
1" NPTF – BRASS
Standard FactoryPre-charge
40 PSIG (2.8 kg/cm2)40 PSIG (2.8 kg/cm2)40 PSIG (2.8 kg/cm2)
DiaphragmMaterial
Butyl RubberButyl RubberButyl Rubber
LinerMaterial
PolypropylenePolypropylenePolypropylene
ModelNumber*RRT-50RRT-12RRT-25
MODELS: RRT-5, RRT-12 MODEL: RRT-25
B
B
Therm-X-Guard Thermal Expansion Tanks