Pneumatics Notes

91
Revised Standard Grade Technological Studies Pneumatic Systems

description

Pneumatic

Transcript of Pneumatics Notes

Page 1: Pneumatics Notes

Revised Standard Grade Technological Studies

Pneumatic Systems

Page 2: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems ii

Contents

Teachers’ Introduction 1

Structure 1

Resources 3

Assessment 3

Student project reports 4

Section 1: Pneumatic Systems 11

Introduction 11

Supplying compressed air 14

Cylinders 16

Valves 19

Circuit simulation software 31

Flow control valves 33

Automatic circuits 49

Sequential control 53

Forces in a single-acting cylinder 57

Forces in a double-acting cylinder 62

Homework assignments 67

Section 2: Electronic Control 81

Section 3: Programmable Control 85

Page 3: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 1

Teachers’ Introduction

Pneumatics is used extensively in industry as well as in many everyday applications.

As a method of completing tasks it has many distinct advantages in terms of energy

consumption, cost and safety. It is important therefore that students gain an

understanding of the benefits of pneumatics as well as the obvious limitations.

When the students have completed this unit of work they should be able to:

interpret pneumatic systems and circuit diagrams

describe the operation of pneumatic systems

pipe-up/construct pneumatic systems

have an appreciation of safety requirements when operating pneumatic systems

perform calculations to determine cylinder pressure, piston force and area

evaluate pneumatic systems.

Structure

This unit is split into three distinct sections:

Section 1 Pneumatic systems

Section 2 Electronic control

Section 3 Programmable control.

It is recommended that these sections be delivered in this order. This provides the

student with a natural progression through the course. The content of the unit is set

out comprehensively so that teachers do not require the use of additional notes or

textbooks. It allows pupils to move at their own pace in many areas but it must be

stressed that these unit notes should not be used as an open-learning pack. It will be

necessary to deliver many important lessons at crucial times.

The materials are intended to be non-consumable; however, this is at the discretion of

each centre. A consumable project report template has been included for each section

of work to provide a structure for reporting work on assignments.

Section 1 Pneumatic systems

This section is concerned primarily with the basic components and operation of

pneumatic circuits. It covers topics such as cylinders, valves, AND/OR control, time

delays, air bleeds, and automatic and sequential circuits. A section of the unit is also

dedicated to relevant calculations involving force, pressure and area.

Wherever possible, use should be made of computer simulation. Throughout these

teaching materials, reference will be made to the FluidSIM package produced by

Festo Didactic, but other packages could be used. Such software not only provides the

facility to construct pneumatic circuits and test them but also to run video clips

showing practical uses of pneumatic systems. This is invaluable to the teaching of this

unit as it provides the students with a reference point in the real world. The

simulations also enhance the practical aspect of this unit.

Page 4: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 2

Problem solving

Students will be required to design, construct and evaluate pneumatic systems to

given specifications. A report template has been included to allow a common

approach to solving problems. This will help students lay out their work in an

appropriate way as well as preparing them for the format of the internal assessment. It

also provides students with a detailed record of their work.

Problem solving is presented in the form of assignments. It is anticipated that much of

the designing will be completed using simulation software; however, it is also

important that students develop a knowledge of real components and the necessary

expertise in connecting components together.

A series of homework tasks has been included. These contain a range of questions

taken from the whole course. The teacher should ensure that homework tasks are

issued at an appropriate time to coincide with work in class. It may also facilitate the

issue and marking of homework if these tasks are completed on consumable

photocopied sheets. Again, this is at the discretion of the centre. Alternatively, these

questions could be used for revision purposes.

Section 2 Electronic control

It is recommended that this section be completed after Applied Electronics. This will

allow students to extend the work done in this area and demonstrate their

understanding further by controlling pneumatic circuits. It also provides excellent

opportunities for integration and a facility to extend the problem-solving aspect of the

course.

Where appropriate, students should make use of a report sheet to record their

solutions to the problems set out in the assignments.

Section 3 Programmable control

It is recommended that this section be completed after Programmable Control. This

will provide the opportunity for students to develop their knowledge and

understanding of control as well as their problem-solving skills. In addition, it

provides and excellent opportunity for integration and allows the students to revisit

pneumatics, helping to keep this area of study fresh in their minds.

It is recommended that students make use of a report template to provide a structure

for reporting work on assignments.

Page 5: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 3

Resources

The majority of resources required to complete this unit are the same as those being

used in Technological Studies at present.

Single-acting spring return cylinders

Double-acting cylinders

3/2 push-button spring return valves

A variety of 3/2 valves with different actuators

5/2 pilot air-operated valves

Solenoid valves

Reservoir

Flow restrictor valves

Circuit simulation software

In addition, the following are required for completion of sections 2 and 3.

Microswitches

Stamp controller

Inputs module

Output driver

Modular electronic boards

Teachers are also encouraged to use any other available resources such as videos and

interactive CD-ROMs.

Assessment

External

This unit of work and the exercises within will prepare the pupils for any pneumatic

questions that appear in the 90-minute exam at the end of the course. It will enable all

pupils to gain the knowledge and understanding required and give them suitable

practice in reasoning and numerical analysis.

Note: The FluidSIM package demonstrated at the launch conference is available from:

Festo Ltd

Automation House

Harvest Crescent

Ancells Business Park

Fleet

Hampshire

GU51 2XP

Web: www.festo.com

Page 6: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 4

Student project reports

These are three student project report proformas for each of the three main areas of

the unit.

1. Pneumatic systems (main section)

This proforma should be used for problem solving situations in the main text.

2. Electronic control

This proforma should be used for problems in electronic pneumatic control.

3. Programmable control

This proforma should be used when attempting projects/problems with pneumatics

and programmable control.

Page 7: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 5

Student Project Report

Pneumatic systems (main section)

Problem (Explain in your own words what the problem is) Specification (A list of everything you want the circuit to do) Block diagram of system

Circuit diagram

Page 8: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 6

Student Project Report

Pneumatic systems (main section – continuation)

Description/explanation of how the system operates Describe how you modified or adjusted the system to affect the operating conditions Evaluation (Have I solved the original problem? Have I met the

specification?)

Page 9: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 7

Student Project Report

Pneumatic systems (electronic control)

Problem (Explain in your own words what the problem is)

Circuit diagram/block diagram of system

Page 10: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 8

Student Project Report

Pneumatic systems (electronic control – continuation)

Description/explanation of how the system operates Describe how you modified or adjusted the system to affect the operating conditions Evaluation (Have I solved the original problem? Have I met the

specification?)

Page 11: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 9

Student Project Report

Pneumatic systems (programmable control)

Problem (Explain in your own words what the problem is) Circuit diagram/block diagram of system Flow chart

Page 12: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 10

Student Project Report

Pneumatic systems (programmable control – continuation)

Description/explanation of how the system operates Program listing Evaluation (Have I solved the original problem? Have I met the

specification?)

Page 13: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 11

Section 1: Pneumatic Systems

Introduction

Pneumatics is something that you probably know very little about yet come across

every day without even realising it. Some examples of everyday pneumatic systems

are shown below. How many do you recognise?

Figure 1

Pneumatics is also used a lot in industry and you would expect to see pneumatic

systems in factories, production lines and processing plants. It can be used to do lots

of different jobs such as moving, holding or shaping objects.

MOVE HOLD

FORM PROCESS

Figure 2

Page 14: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 12

Every one of these pneumatic systems makes use of compressed air. Compressed air

is quite simply the air that we breathe forced or squashed into a smaller space. We can

use the energy stored in this compressed air to do things.

To understand how compressed air is able to do things, let’s think of a ball. If we

blow up the ball so that it is full, it will contain a lot of compressed air. If we bounce

the ball, it will bounce very high. However, if the ball is burst then the compressed air

will escape and the ball will not bounce as high. Quite simply, the ball bounces

because it is using the energy stored in the compressed air.

Figure 3

Basically, all pneumatic systems make use of compressed air to do work. We can

show this in a systems diagram.

Pneumatic

system

Compressed

airWork

Figure 4

Page 15: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 13

Advantages of pneumatics

There are usually lots of different ways to carry out a task, so it is important to

understand some of the reasons for choosing pneumatic systems.

Clean

Pneumatic systems are clean because they use compressed air. We know already that

this is just the air we breathe forced into small spaces. If a pneumatic system develops

a leak, it will be air that escapes and not oil. This air will not drip or cause a mess and

this makes pneumatics suitable for food production lines.

Safe

Pneumatic systems are very safe compared to other systems. We cannot, for example,

use electronics for paint spraying because many electronic components produce

sparks and this could cause the paint to catch fire.

It is important, however, that we look after and maintain the different components. It

is also important that we follow the correct safety rules.

Reliable

Pneumatic systems are very reliable and can keep working for a long time. Many

companies invest in pneumatics because they know they will not have a lot of

breakdowns and that the equipment will last for a long time.

Economical

If we compare pneumatic systems to other systems, we find that they are cheaper to

run. This is because the components last for a long time and because we are using

compressed air. Many factories already have compressed air for other reasons.

Flexible

Once you have bought the basic components, you can set them up to carry out

different tasks. Pneumatic systems are easy to install and they do not need to be

insulated or protected like electronic systems.

Assignment 1

1. Give three examples of the everyday use of pneumatics.

2. Choose one of your examples from question 1. Draw a system diagram and

describe how it makes use of compressed air.

3. What is compressed air?

4. Think about blowing up a balloon. What happens to the balloon if you let it go?

Why does this happen?

5. Give two reasons why pneumatic systems are used in industry.

Page 16: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 14

Supplying compressed air

We know already that pneumatic systems need compressed air to make them work. A

bicycle pump can produce compressed air. This is all right for inflating the tyres on

your bicycle, but can you imagine trying to blow up all the tyres on a lorry using this?

You would soon become tired, exhausted even.

In order to supply pneumatic systems with compressed air we use a machine called a

compressor. Compressors come in lots of different shapes and sizes but they all work

in the same way.

Figure 5

A pump that is driven by a motor, sucks in air from the room and stores it in a tank

called the receiver. You will be able to hear the compressor when it is running.

Sometimes though, it will stop because the receiver is full.

Ask your teacher to see the compressor that will be supplying your compressed air.

Not everyone in your class could connect directly to the compressor, as this is not

practical. Instead, a pipe takes the compressed air from the receiver to various points

around the room. We would normally connect a device called a manifold to these

points. The manifold lets us connect lots of components to the compressed air. It also

lets us switch our circuits on and off.

ON

OFF

Figure 6

Page 17: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 15

Safety rules

Safety rules help to keep us safe. They highlight dangers and this helps to prevent

accidents. When we are using pneumatics we must follow these rules.

1. Never blow compressed air at anyone, not even yourself.

2. Never let compressed air come into contact with your skin, as this can be very

dangerous.

3. Always wear safety goggles when you are connecting and operating circuits.

4. Check that all airlines are connected before turning on the main air supply.

5. Always turn off the main air supply before changing a circuit.

6. Keep your hands away from moving parts.

7. Avoid having airlines trailing across the floor or where someone could trip or

become entangled.

Assignment 2

1. What machine is used to compress the air?

2. How does this machine work?

3. Why does it stop occasionally?

4. What is the purpose of a manifold?

5. Why is it important to follow the safety rules when using pneumatics?

Page 18: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 16

Cylinders

Pneumatic equipment can be split up into two basic categories of cylinders and

valves.

Cylinders are the ‘muscles’ of pneumatic systems as they are used to move, hold and

lift objects. They can even be used to operate other pneumatic components. Cylinders

are operated by compressed air and they covert the stored energy in the compressed

air into linear motion.

Linear motion is motion in a straight line: an apple falling from a tree or a sliding door

closing are examples of linear motion. We can represent linear motion by arrows like

the ones below.

Figure 7

There are two types of cylinder that we will be using: single-acting cylinders and

double-acting cylinders.

Single-acting cylinder

A single-acting cylinder requires only one air supply. If we supply compressed air to a

single-acting cylinder, the air pushes against the piston inside the cylinder and causes

it to outstroke. When the piston has fully outstroked it is said to be positive.

positive

Air in

Figure 8

Page 19: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 17

If we stop the supply of air then the spring inside the cylinder causes the piston to

instroke to its starting position and the piston is said to be negative. As this happens,

the air inside the cylinder is pushed back out.

negative

Air out

Figure 9

The symbol for a single-acting cylinder is shown below.

Figure 10

Single-acting cylinders are easy to use and control but they do not produce very big

forces. This means that we need to be careful of what we use them for.

Double-acting cylinder

A double-acting cylinder has no spring inside to return it to its original position. It

needs two air supplies, one to outstroke the piston and the other to instroke the piston.

To outstroke a double-acting cylinder we need compressed air to push against the

piston inside the cylinder. As this happens, any air on the other side of the piston is

forced out. This causes the double-acting cylinder to outstroke. When the piston has

fully outstroked it is said to be positive.

positive

Air in Air out

Figure 11

To instroke a double-acting cylinder we need to reverse this action. We supply the

compressed air to the other side of the piston. As the air pushes the piston back to its

original position, any air on the other side is again forced out. This causes the piston

to instroke and it is said to be negative.

Page 20: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 18

negative

Air inAir out

Figure 12

The symbol for a double-acting cylinder is shown below.

Figure 13

Double-acting cylinders are used more often in pneumatic systems than single-acting

cylinders. They are able to produce bigger forces and we can make use of the

outstroke and instroke for pushing and pulling.

Page 21: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 19

Valves

Valves control the flow of compressed air to a cylinder. They can be used to turn the

air on or off, change the direction in which the air is flowing or even slow down the

airflow. The most common type of valve is the 3/2 valve.

3/2 valve

A 3/2 valve gets its name because it has three ports and two states. A port is where we

can connect a pipe and a state is simply a position that the valve can be in. The ports

are numbered to help us make the right connections. The numbers will be stamped

onto the casing of the valve.

Port 1 – main air

This port is connected to main air. Remember that our main air is supplied through a

manifold. Main air is identified by this symbol:

Figure 14

Port 2 – output connection

This port lets us make connections to other components. Remember, the purpose of

valves is to control the flow of air to other components, usually cylinders.

Port 3 – exhaust

This port allows air trapped in the circuit to escape or exhaust. Remember, for our

cylinders to instroke and outstroke, they need the air on the other side of the piston to

escape.

Figure 15

The 3/2 valve has two states of operation. One state prevents air from being supplied

to other components and the other allows the air to flow freely.

Page 22: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 20

State 1 – off/unactuated state

In this state, the main air supply through the valve is blocked and so air is unable to

reach other components, such as cylinders. However, any air within the cylinder is

able to exhaust through the valve and this will allow the cylinder to return to its

original position.

Study the symbol below and ensure that you understand how the air flows through the

valve.

1

3

2

Figure 16

State 2 – on/actuated state

In this state, the main air supply is able to flow freely through the valve and supply

components, such as cylinders, with air.

Study the symbol below and ensure that you understand how the air flows through the

valve.

1 2

3

Figure 17

The complete symbol for a 3/2 valve combines both states and is usually drawn in the

off or unactuated state. The complete symbol is shown below.

Figure 18

Page 23: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 21

Actuators

There are a number of different ways that we can operate a 3/2 valve. The most

common way is by using a push button. By pressing the button, the valve changes to

the actuated state and allows main air to flow through to other components. If we

release the button, a spring inside returns the valve to its off state. The symbol for a

push button, spring return 3/2 valve is shown below.

Figure 19

Below is a list of the most common types of actuators. They are always drawn onto

the standard symbol for the 3/2 valve.

PLUNGER

PUSHBUTTON

LEVER

ROLLER

ROLLERTRIP

SOLENOID

PILOT AIR

DIAPHRAGM

SPRING

FOOTPEDAL

Figure 20

Page 24: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 22

Simple circuits using single-acting cylinders

A city-centre car park has a barrier system to prevent people parking illegally. The car

park attendant checks all the cars entering and leaving the car park. The barrier is

raised and lowered by a single-acting cylinder. The attendant pushes a button to

operate the system.

Figure 21

The systems diagram is shown below.

3/2 ValvePress

buttonBarrier

raisesCylinder

Figure 22

The pneumatic circuit is shown below.

Figure 23

When the button is pressed, the valve changes state and supplies air to the single-

acting cylinder. This causes the piston to outstroke with enough force to raise the

barrier.

Page 25: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 23

Figure 24

When the button is released, the valve returns to its original state and the piston is able

to instroke ready for the process to begin again.

Assignment 3

(a) Build the circuit for raising and lowering the car park barrier.

(b) Press the button on the valve and keep it pressed. Explain what happens.

(c) Release the button and explain what happens.

(d) Using the correct terminology, explain how the circuit operates to raise and lower

the barrier.

(e) Sometimes the attendant needs to inform the drivers of where to park, especially

when it is very busy. The problem is that when he lets go of the button, the barrier

begins to fall. Someone suggests changing the actuator on the 3/2 valve. What

actuator could be used instead and how does this affect the way the circuit works?

T-piece

A T-piece or T-connector is a very simple component that lets us split or divide

airflow. It can be very useful if you want two cylinders to operate at the same time.

AIR OUT

AIR IN

AIR OUT

Figure 25

On circuit diagrams, the T-piece is identified by a dot.

T-piece

Figure 26

Page 26: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 24

Assignment 4

1. A delivery lorry uses a pneumatic braking system. The brakes operate when the

driver presses the foot brake. Two single-acting cylinders should outstroke at the

same time and press against the wheels. The pneumatic circuit is shown below.

Figure 27

(a) Build and test the circuit shown. (You can use a push button, spring return 3/2

valve instead of a foot pedal.)

(b) Explain the purpose of the T-piece.

2. Four single-acting cylinders are used to clamp large nameplates to a table to allow

them to be engraved. All four cylinders must operate at the same time.

AIR SUPPLY

Figure 28

(a) Design a pneumatic system to solve this problem.

(b) Build and test your solution.

(c) Explain your choice of actuator.

Page 27: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 25

Simple circuits using double-acting cylinders

We know already that double-acting cylinders do not have a spring inside to return

them to their original position. This means that we need to use compressed air to

outstroke and instroke the piston. One way to do this is to connect a 3/2 valve to either

side of the double-acting cylinder.

Remember our car park problem. Someone has suggested changing the single-acting

cylinder to a double-acting one.

Figure 29

The pneumatic circuit would now look like this.

Valve A Valve B

Figure 30

When the attendant actuates valve A by pressing the button, the double-acting

cylinder outstrokes and lifts the barrier. It stays in this position until valve B is

actuated. This allows the piston to instroke and the barrier is lowered.

Page 28: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 26

Assignment 5

(a) Build the circuit shown above for raising and lowering the barrier.

(b) Press the button on valve A to outstroke the cylinder. Does the piston instroke

when you release the button?

(c) Press the button on valve B. What happens to the cylinder?

(d) What happens when you press both buttons at the same time?

(e) Actuate valve A again and then try pushing against the piston. Why is it so easy to

move?

(f) What type of problems could this cause in this particular circuit?

Page 29: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 27

5/2 valves

There are many problems when controlling a double-acting cylinder with two 3/2

valves. You should have discovered from the last circuit that it is easy to push or pull

the piston. This is because you do not have a constant supply of air to keep the piston

in place. When you actuate the 3/2 valve, it outstrokes the piston. When the 3/2 valve

is not actuated, air is free to escape or exhaust back through the valve. This means that

any force or effort placed on the piston will make it move easily.

Figure 31

A further disadvantage is that the 3/2 valve needs to be actuated until the double-

acting cylinder has fully outstroked or instroked. Releasing the valve before the stroke

is complete will mean the piston will stop short of its final position.

We have greater control over a double-acting cylinder if we control its outstroke and

instroke using a 5/2 valve. This valve has five ports and two states of operation. The

ports are always numbered in the same way.

Port 1 – main air

This port is connected to main air just like a 3/2 valve.

Port 2 – output connection

This port is usually connected to instroke a double-acting cylinder.

Port 3 – exhaust

This port allows air trapped in the double-acting cylinder to escape. Remember, for

the cylinder to instroke and outstroke, air on the other side of the piston must be

allowed to escape. If this did not happen, the piston would not move.

Port 4 – output connection

This port is usually connected to outstroke a double-acting cylinder.

Port 5 – exhaust

Again, this port lets the air on the other side of the piston escape.

A 5/2 valve has two states of operation. One state supplies air to outstroke a double-

acting cylinder and the other state will cause it to instroke.

Page 30: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 28

State 1 instroke

In this state, the main air flows through the valve from port 1 to port 2. Any air within

the cylinder is able to exhaust through the valve from port 4 to port 5. In this state, a

5/2 valve will cause a double-acting cylinder to instroke or hold the piston in the

negative position. This means that air is always being supplied to the cylinder.

Study the symbol below and ensure that you understand how the air flows through the

valve.

1

2

3

4

5

AIR FROMCYLINDER

AIR TOCYLINDER

Figure 32

State 2 – outstroke

In this state, the main air flows through the valve from port 1 to port 4. Any air on the

other side of the piston is able to exhaust through the valve from port 2 to port 3. In

this state, a 5/2 valve will cause a double-acting cylinder to outstroke and will hold it

in the positive position.

Study the symbol below and ensure that you understand how the air flows through the

valve.

1

2

3

4

5

AIR FROMCYLINDER

AIR TOCYLINDER

Figure 33

The complete symbol for a 5/2 valve is shown. The cylinder, main air and exhaust

lines are only ever drawn on one half of the symbol, depending on which part is active

in the circuit. It is usual, however, to draw the symbol so that it would hold a double-

acting cylinder in the negative position.

Page 31: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 29

Figure 34

Pilot air

5/2 valves can be operated or actuated in the same way as 3/2 valves. However, the

most common way of actuating a 5/2 valve is by pilot air. A pilot air 5/2 valve will

change state when a brief air signal acts at either end of the valve. This signal is most

often supplied from a 3/2 valve. In the example shown below, the button on valve A

only needs to be pressed for a moment in order to change the state of the 5/2 valve.

The 5/2 valve supplies the double-acting cylinder with air to make it outstroke.

Valve A

Figure 35

Notice that the pilot airlines to the 5/2 valve are drawn as broken or dashed lines to

distinguish them from the other air lines in the circuit.

Page 32: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 30

Assignment 6

1. Our car park barrier is gradually improving. The circuit has been changed to look

like the one shown in figure 35.

(a) Build and test the circuit.

(b) Produce a list of all the components used.

(c) Describe how the circuit works.

(d) A door entry system is controlled by pneumatics. The system makes use of a

double-acting cylinder. Part of the circuit diagram is shown below.

A

B

C

Figure 36

2.

(a) Name each of the components A, B and C.

(b) Complete the diagram so that the door will open and close.

(c) Describe how the circuit operates.

Page 33: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

31

Circuit simulation software

It is possible to use circuit simulation software such as that produced by Festo

Didactic to investigate pneumatic circuits. Circuit simulation software is widely used

in industry to design and model circuits and to test them to see if they work properly.

This can save a lot of time and money.

We use simulation software in school for these same reasons but it also allows us to

test circuits that we may not have all the equipment for.

Assignment 7

Using a pneumatic simulation software package, construct and test the following

circuits. Make sure that you have built the circuit in exactly the same way as the ones

shown. To test the circuit you need to press the ‘play’ button on the toolbar or select

‘Start’ from the ‘Execute’ menu. Now click on the 3/2 valve to see the circuit work.

1.

Figure 37

2.

Figure 38

The software can be used for much more than just building and testing circuits. You

can also see pictures of components, learn more about them and even see short films

Page 34: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 32

of them working. To do these things you go to the Didactics menu. Here you can

select ‘Component Description’, ‘Component Photo’ or ‘Educational Film’.

An example of a component photo is shown below.

Figure 39

Take some time to select different components and view their descriptions and photos.

It is also worthwhile looking at some of the video clips.

Page 35: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

33

Flow control valves

You should have noticed in the circuits you have built so far that the pistons move

very quickly. Sometimes this can be dangerous or it may prevent the circuit from

working properly. To slow down the speed of a piston we use a flow control valve.

There are two types of flow control valve available to us. The first type is called a

restrictor (or sometimes a throttle valve). This valve works by reducing the amount of

space that the air can flow through. We can adjust the airflow by turning the small

screw on top of the valve. The symbol for a restrictor is shown below.

Figure 40

This restrictor slows down the flow of air in both directions. This means that using

only one extra component can slow both the outstroke and instroke of a cylinder.

In the circuit shown below, the restrictor is used to slow down the speed of the single-

acting cylinder. We can adjust this speed by turning the small screw on the top of the

restrictor.

Figure 41

The problem with this type of restrictor is that it always slows down the speed of the

piston in both directions. In many cases, we would only want either the outstroke or

the instroke to be slowed down. Also, if we study the piston movement very carefully,

we sometimes find that it is quite jerky not smooth as we would want it to be.

Page 36: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 34

Unidirectional restrictor

To solve these problems we can use a component called a unidirectional restrictor.

As its name suggests, it only slows down the air in one direction. The symbol is

shown below.

1 2

Figure 42

When air flows into port 1 of the restrictor, some of the air takes the bypass route. A

small ball is blown against a valve and blocks this path. The air is then forced to go

through the restriction and this slows down the airflow.

AIR-FFLOW

RESTRICTION

BYPASS

1 2

Figure 43

When air flows into port 2 of the restrictor, again some of the air takes the bypass

route. This time, the ball is blown away from the valve and the air passes through

unrestricted.

AIR-

FLOW

RESTRICTION

BYPASS

1 2

Figure 44

In pneumatics, unidirectional restrictors are much more useful to us. However, we

must always be careful to insert them in the circuit the correct way round.

Page 37: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

35

Remember our car park barrier. The attendant has complained that the barrier rises too

quickly and is worried that this may damage it. Someone suggests changing the circuit

to the one shown below.

Valve A Valve B

Figure 45

Study this circuit and take note of the position of the unidirectional restrictor. Is it

where you expected? The restrictor is placed so that it slows down the exhaust air

coming from the cylinder. When valve A is pressed, the 5/2 valve changes state and

starts to supply the cylinder with air to make it outstroke. Air trapped on the other side

of the piston escapes through the restrictor slowly. This makes the piston outstroke

slowly.

We always restrict the exhaust air coming from a cylinder as this makes the piston

move much more smoothly.

Page 38: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 36

Assignment 8

1. Build and test the circuit shown to raise the barrier slowly.

(a) Why do we restrict the exhaust air to slow down the speed of the piston?

2. For safety reasons, the entrance door to a storeroom in a supermarket must open

and close slowly. A double-acting cylinder is used to slide the door.

Figure 46

A simplified circuit diagram is shown below with some of the piping missing.

Valve A Valve B

Figure 47

(a) Complete the diagram.

(b) Build and test the circuit.

(c) Explain why two restrictors are needed in this circuit.

Page 39: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

37

3. Part of a manufacturing process involves dipping components into a chemical

solution to prepare them before they are painted.

Figure 48

A double-acting cylinder controls the process and for safety reasons the cylinder must

outstroke and instroke slowly.

(a) Using a computer simulation program, design a circuit that would solve this

problem.

(b) Build and test your solution using components.

(c) How well does your circuit operate? Why is it important that the cylinder

operates slowly?

Page 40: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 38

AND control

Although pneumatic circuits are very safe, it is important to take safety precautions.

AND control circuits can be used to help prevent accidents by ensuring that guards

are in position before machines are switched on. These circuits can also be used to

stop a machine being switched on accidentally or to stop operators placing their hands

in the machine when it is running.

SLIDINGDOOR

VALVEPOSITION

Figure 49

AND control involves connecting 3/2 valves together in series. This means that the

output from one valve becomes the input to another. Study the diagram below.

Valve A Valve B

Figure 50

The single-acting cylinder will only outstroke when valve A and valve B are pressed

at the same time. When the button on valve A is pressed, main air passes through and

reaches valve B. The air cannot flow any further until valve B is pressed. This then

supplies the cylinder with air and it outstrokes.

We can summarise how the circuit behaves in a truth table.

Page 41: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

39

VALVE A

OFF

ON

OFF

ON

VALVE B

OFF

OFF

ON

ON

CYLINDER

INSTROKE

INSTROKE

INSTROKE

OUTSTROKE

Figure 51

Assignment 9

1. A company logo is to be stamped onto boxes using a single-acting cylinder. To

prevent accidents, the machine will only work when the operator has both hands

on the start buttons. If either button is released, the machine will stop.

BOX BOX BOX BOX

STAMP

Figure 52

(a) Design a circuit that would solve this problem.

(b) Build and test your solution.

(c) Draw a truth table of your results.

(d) Explain how the circuit operates.

2. Sometimes the operator manages to jam the buttons on so that he can move some

of the boxes on the conveyor belt. This is very dangerous and the manager wants

the machine guarded. It should now only work when the guard is in position and

the operator has both hands on the buttons.

(a) Redesign the circuit to this specification.

(b) Build and test your solution.

(c) Explain how your solution works.

Page 42: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 40

OR control

Sometimes we need to control a pneumatic circuit from more than one position. This

can be done using OR control circuits. These circuits are quite simple but they need

another component called a shuttle valve.

A shuttle valve is used to change the direction of air in a circuit. It has a small ball

inside that gets blown from side to side. A picture is shown below.

FROMVALVE A

TO CYLINDER

FROMVALVE B

Figure 53

When air is supplied from valve A, the ball gets blown across and the air is directed

towards the cylinder. When air is supplied from valve B, the ball is blown to the other

side and again the air flows into the cylinder. If air comes from both directions, air

still manages to reach the cylinder, as this is the only path it can take.

The symbol for a shuttle valve is shown below.

Figure 54

OR control involves connecting 3/2 valves together in parallel. This means that either

valve will outstroke the cylinder. Study the diagram below.

Valve A Valve B

Shuttle valve

Figure 55

Page 43: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

41

If the button on valve A is pressed, the ball in the shuttle valve is blown across

towards B and the cylinder outstrokes. If the button on valve B is pressed, the ball is

blown across towards A and the cylinder outstrokes. The circuit works if valve A or

valve B is actuated.

We can summarise the behaviour of this circuit in a truth table.

VALVE A

OFF

ON

OFF

ON

VALVE B

OFF

OFF

ON

ON

CYLINDER

INSTROKE

OUTSTROKE

OUTSTROKE

OUTSTROKE

Figure 56

Assignment 10

1. Part of a production line involves a quality check. If goods are seen to be faulty

then they are pushed off the conveyor by a single-acting cylinder. Two people are

used to make sure that no faulty goods leave the factory. They operate the cylinder

by pressing a button.

Figure 57

(a) Design a circuit to solve this problem.

(b) Build and test your solution.

(c) Draw a truth table of your results.

(d) Someone has suggested changing the shuttle valve to a T-piece. Why is this

not a good idea? (You might want to build this circuit to investigate.)

Page 44: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 42

2. A bus door is operated by pneumatics. The door is operated by a single-acting

cylinder and controlled by a 3/2 valve. In an emergency, there should be a second

valve that allows passengers to open the doors.

Figure 58

(a) Design a circuit to solve this problem.

(b) Build and test your solution.

(c) Explain your choice of actuators.

Page 45: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

43

3. A pneumatic circuit has been devised for use in operating a sliding door. It must

be possible for the door to be opened or closed from both the inside and outside.

The speed of the door should be controlled when opening and closing.

(a) A diagram of the components is shown below with some of the piping missing.

Complete the diagram.

CLOSE (OUTSIDE)

CLOSE (INSIDE)

OPEN (OUTSIDE)

OPEN (INSIDE)

Figure 59

(b) Build and test the solution.

(c) Name all of the components used.

(d) What type of control does this circuit use?

Page 46: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 44

Time delay

Sometimes in a circuit we want a pause or delay before something else happens. To

create a delay we need to use two components – a unidirectional restrictor and a

reservoir.

A reservoir is simply an empty container, just like an empty bottle. The bigger the

reservoir, the longer it takes to fill up with air. To make the delay longer we use a

unidirectional restrictor in front of the reservoir. This slows down the air so that the

reservoir takes even longer to fill. The length of time it takes to fill creates the delay.

Air

Figure 60

We can change the length of a delay by changing the size of the reservoir or adjusting

the restrictor.

Time delays can be very useful in clamping operations when objects need to be held

in place by a cylinder for a specific amount of time to glue or set.

Figure 61

In this type of example the delay has to occur before the cylinder would instroke.

Study the circuit diagram.

Page 47: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

45

Figure 62

When the push button is pressed, the 5/2 valve changes state and the cylinder

outstrokes. As it outstrokes, it pushes the former together and the hot plastic sheet is

pressed into shape. As this happens it also actuates the roller. Air now flows through

the restrictor and starts to fill up the reservoir. Once the reservoir is full, the 5/2 valve

changes state and the cylinder instrokes, ready for the process to begin again.

Page 48: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 46

Assignment 11

1. Build and test the circuit shown.

(a) Adjust the restrictor to achieve a time delay of three seconds.

2. Sand is fed into a hopper from above. When the hopper is full, the operator

presses the button and a double-acting cylinder slides open the door. This lets the

sand fall into a wagon underneath. The operator now presses the other push

button, but there must be a short delay before the hopper door closes to ensure that

all the sand has emptied out. Study the circuit diagram.

Valve A Valve B

Figure 63

(a) Which two components are needed to create a time delay?

(b) Insert these components into the circuit diagram. Build and test your solution

to ensure that it works properly.

(c) What other improvements would you make to this circuit?

3. Wonderful Worktops is a company that manufactures worktops for kitchens. The

worktops are made from Formica sheets glued onto chipboard. A pneumatically

controlled clamp holds down the glued sheet for 10 seconds before releasing it

automatically.

Figure 64

(a) Design a solution to this problem.

(b) Build and test your solution.

(c) Explain how the circuit operates.

Page 49: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

47

Air bleed

Sometimes with pneumatics we find that the actuators on valves can get in the way of

the circuit. Also, some actuators need a big force to make them work and this is not

always possible. There are different ways to overcome these problems and one of the

most common is to use an air bleed.

An air bleed is simply an open pipe that allows the air in the circuit to escape. This air

must be at a low pressure, otherwise the pipe would ‘wave’ about and be dangerous.

Air bleed circuits rely on a component called a diaphragm valve. This valve is capable

of detecting small changes in air pressure. The valve works in the same way as other

3/2 valves; it is only the actuator that is new to us. The symbol is shown below.

Figure 65

The diaphragm is a piece of rubber stretched inside the valve. When air flows into the

top of the valve, the rubber expands much in the same way as when a balloon is

blown up. When the diaphragm expands, it presses down inside the valve and changes

its state.

The signal to the diaphragm comes from an air bleed. When the air bleed is blocked,

air is diverted back towards the diaphragm. This actuates the 3/2 valve and the

cylinder outstrokes. Notice that the airflow to the air bleed passes through a restrictor.

This slows down the air before it is allowed to escape.

Figure 66

Page 50: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 48

Assignment 12

1. The manufacturer of crystal ornaments wants to print a ‘Fragile!’ warning on

every box before it leaves the factory. A simple pneumatic machine will stamp the

boxes, which vary in size and weight. The packages are not spaced regularly on

the conveyor belt and so the printing should only take place when a package is in

the correct position. A possible solution is shown.

Figure 67

(a) Build and test the circuit for printing the packages.

(b) Explain why an air bleed is used to sense the position of the boxes.

(c) Someone has noticed that the cylinder outstrokes so fast that there is a risk that

the small ornaments may be broken. Alter the circuit to slow down the

operation of the single-acting cylinder.

2. Crates containing cans of beans are moved to the dispatch area by a series of

conveyor belts. The crates are quite heavy and two single-acting cylinders are

needed to push the crates from one belt to another.

AIR BLEED

Figure 68

(a) Design a pneumatic circuit to solve this problem.

(b) Build and test your solution.

(c) Why is pneumatics often used in food production lines?

Page 51: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

49

Page 52: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 50

Automatic circuits

Automatic circuits are commonly found on production lines. They help to speed up

production and make sure that the goods are all manufactured to the same standard.

There are two types of automatic circuit: semi-automatic and fully automatic.

Semi-automatic

A semi-automatic circuit is one that completes a process once it has been started,

usually by a human operator. We have come across semi-automatic circuits already in

the course. You should recognise the two circuits shown below.

Circuit 1

Circuit 2

Figure 69

Page 53: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

51

Fully automatic

A fully automatic circuit is one that continues to work, performing a task over and

over again. It does not stop or wait for input from an operator. These circuits make

use of actuators such as a roller trip and plunger to detect the position of the piston as

it instrokes and outstrokes.

Automatic circuits produce reciprocating motion. This is motion up and down like the

needle on a sewing machine. It can also be left and right, or forwards and backwards

along a straight line. We can represent reciprocating motion by arrows like these: For

example, a polishing machine requires the reciprocating motion of a double-acting

cylinder.

Figure 70

Page 54: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 52

Figure 71

The pneumatic circuit is shown below.

Valve A Valve B

XY

Figure 72

As the piston instrokes, it trips valve A and the 5/2 valve changes state and the piston

is sent positive. When it is fully outstroked, it trips valve B and the 5/2 valve returns

to its original position, allowing the piston to instroke. The process begins all over

again and continues to operate.

Assignment 13

1. Build and test the circuit for the polishing machine.

(a) You should have noticed that the only way to stop the circuit is to turn off the

main air supply. It would be much better if we could use a lever-operated 3/2

valve to do this. It has been suggested that the valve be placed at either point X

or point Y. Try both positions and record what happens.

(b) Which position do you think is better and why?

(c) Why must a lever-operated 3/2 valve be used?

2. A small company that makes spice racks wants to automate some of its

production. To begin with, a drilling operation is to be controlled by a pneumatic

cylinder. An operator will start the sequence and then the drill will be lowered

automatically into the wood. Once the hole has been drilled to the correct depth,

the cylinder should automatically instroke ready for the process to start again.

Page 55: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

53

DEPTH STOP

ROLLER TRIP

DRILL

WORK PIECE

Figure 73

A layout of all the components needed is shown with the piping missing.

Figure 74

(a) Complete the diagram.

(b) Name each component.

(c) Build and test your solution.

(d) The cylinder outstrokes far too quickly and the drill bits keep breaking. Alter

the circuit so that the cylinder outstrokes slowly.

Page 56: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 54

Sequential control

Many pneumatic systems and machines are designed to perform a range of tasks in a

certain order or sequence. This usually involves the use of two or more cylinders

working together to complete the task.

For example, a company has automated its production line that involves metal blocks

being placed in a furnace for heat treatment. One cylinder is used to open the furnace

door and another pushes the metal blocks into the furnace.

A

Figure 75

The sequence of operations for this process is as follows.

(a) An operator pushes a button to start the process.

(b) The furnace door is opened.

(c) The block is pushed into the furnace and the piston instrokes.

(d) The furnace door is closed.

(e) The sequence stops.

For this system to work successfully, we need to fully understand the order and

movement of cylinders A and B.

Stage 1

Cylinder A instrokes to raise the furnace door.

Stage 2

Cylinder B outstrokes and pushes the metal block into the furnace.

Stage 3

Cylinder B instrokes.

Page 57: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

55

Stage 4

Cylinder A outstrokes and closes the furnace door.

The pneumatic circuit that carries out this operation is shown below.

CYLINDER B

CYLINDER A

VALVE A

VALVE B

VALVE C

VALVE D

VALVE E

VALVE F

VALVE G

VALVE H

VALVE I

Figure 76

Page 58: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 56

The system begins by actuating valve A. This changes the state of valve B and causes

cylinder A to instroke, raising the door. When fully instroked, or negative, the piston

trips valve C and this sends a signal to valve D. This 5/2 valve changes state and

sends cylinder B positive. When fully outstroked, the piston trips valve E and the

cylinder instrokes. When negative, valve F is actuated and causes cylinder A to

outstroke and stay in the positive position. The system stops and waits for a signal

from valve A.

We can summarise the sequence of this circuit as follows.

Start, A, B+, B, A+, Stop

Assignment 14

1. Study this sequential circuit.

(a) Name the components labelled Valve D, Valve F and Valve H.

(b) If Valve H were removed from the circuit, explain the effect this would have

on the operation of the furnace door.

(c) Using appropriate terminology, explain how the circuit operates, starting, from

when Valve A is pressed.

(d) A short delay is required before Cylinder B goes positive. Redraw the circuit

to take this into account.

2. A pneumatic system is used to transfer packages between conveyor belts as

shown. The pneumatic circuit is also shown.

Cylinder A

Cylinder B

Valve 1

Figure 77

The sequence of operation of the cylinders is A+, B+, A, B.

Page 59: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

57

CYLINDER A CYLINDER B

1

2

3 4

5

6

Figure 78

(a) Build and test this circuit.

(b) Name valves 1, 2 and 4.

(c) Describe how the circuit operates.

(d) If the packages were too light to actuate valve 1, describe another way to

detect the packages.

(e) The outstroke speed of the cylinders needs to be slowed down. Describe how

you would do this.

Page 60: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 58

Forces in a single-acting cylinder

When a single-acting cylinder outstrokes, it produces a force. We can use this force to

carry out tasks. When we are designing pneumatic circuits, we must use a cylinder

that is capable of completing its task. For example, if a single-acting cylinder is used

to push parcels off a conveyor belt, then it must produce a big enough force to be able

to do this. If the force is not big enough, then the parcels will not move, and if the

force is too big, the parcels may be damaged.

The size of the force produced by the cylinder as it outstrokes depends on two things

the air pressure supplied to the cylinder and the surface area of the piston. This

means that if we want a bigger force we can either use a larger piston or increase the

air pressure. However, it is not a good idea to increase the air pressure because this

can damage components.

The instroke of a single-acting cylinder is controlled by a spring. The spring returns

the piston to its original position. We do not normally use the instroke of a single-

acting cylinder to carry out tasks.

Page 61: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

59

Pressure

Air pressure is measured in bars or in N/mm2

(newtons per square millimetre). We can

measure the pressure in a pneumatic system using a pressure gauge. A gauge will

always be connected to the compressor, but other gauges may be connected

throughout large systems. This helps to detect leaks, as the pressure in the system

would begin to fall if air was escaping from the pipes.

Whenever we use pressure in calculations, we require the units to be in N/mm2. This

sometimes means converting from bars to N/mm2. This conversion is easy, as you

simply divide the value in bars by 10. For example, if the pressure supplied to a

system is 5 bars, we can find the equivalent value in N/mm2 by simply dividing 5 by

10. Therefore, the value would be 0.5 N/mm2.

The chart below provides a quick reference.

0

0

1 2 3 4 5 6 7 8 9 10

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1

bar

N/mm2

Figure 79

Page 62: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 60

Area

The surface area of the piston is the area that the air pushes against to outstroke the

piston. This area is circular.

Figure 80

The area of a circle is calculated using the formula

4

22 d

rArea

where r is the radius and d is the diameter of the circle.

Page 63: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

61

Force

The force produced when a single-acting cylinder outstrokes is calculated using the

formula:

Force = Pressure Area

where force is measured in newtons (N), pressure is measured in N/mm2 and area is

measured in mm2.

In some situations, we would know the size of the force needed to do a job properly.

In this case, we would want to calculate the pressure needed or the size of the piston.

To do this we need to rearrange our formula.

Pressure = Force

Area

Area = Force

Pressure

Worked example

Air is supplied to a single-acting cylinder at a pressure of 4 N/mm2. The diameter of

the piston is 25 mm. Calculate the force produced as the piston outstrokes.

Step 1

Write down any information that you have from the question.

Pressure = 4 N/mm2

Diameter = 25 mm

Step 2

We need to calculate the surface area.

2

2

2

mm491

4

2514.3

4

d

Area

Step 3

Use the correct formula for what you are trying to find. In this case, calculate the

force.

Force = Pressure Area

= 4 491

= 1964 N

Force = 1.96 kN

Page 64: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 62

Assignment 15

1. Write down the formula that we use to calculate the force in a single-acting

cylinder as it outstrokes.

2. A pneumatic stamping machine is used to stamp the company logo onto metal

casings. It is discovered that the stamp does not imprint the logo properly. Suggest

ways of increasing the size of the force produced by the cylinder.

3. What controls the instroke of a single-acting cylinder?

4. A single-acting cylinder is used to press two sheets of acrylic together when they

are gluing. The process requires a force of 300 N. The only piston available has a

diameter of 20 mm and it is supplied with air at a pressure of 0.3 N/mm2. Will this

arrangement enable this process to be carried out properly?

5. What force will be produced by a 20 mm diameter cylinder as it goes positive

using a pressure of 0.8 N/mm2?

6. Calculate the outstroke force produced by a 40 mm diameter cylinder when it

operates with a supply pressure of 3 bars.

7. Write down the formula that we would use to calculate the pressure of a system if

we already knew the force required and the size of the cylinder available.

8. A stamping machine exerts a force of 454 N with a piston diameter of 34 mm.

Calculate the air pressure required for this operation.

9. A machine that places tops on bottles uses a single-acting cylinder. The process

requires a force of 650 N. What air pressure needs to be supplied to the cylinder

with a diameter of 56 mm?

10. A force of 540 N is needed to push a packing case off a conveyor belt. The single-

acting cylinder used has a diameter of 60 mm. What air pressure should be

supplied to the system?

11. A pneumatic system is used to test the quality of drawer guides in kitchen

cabinets. A force of 16 N is needed to open the drawer. The single-acting cylinder

available has a piston diameter of 10 mm. What air pressure should be supplied?

12. Write down the formula we would use to find the area of a piston if we already

knew the size of the force it needed to produce and the air pressure being supplied.

13. A single-acting cylinder is used to lift parcels on to a conveyor. This requires a

force of 180 N with the system operating at a pressure of 6 bars. Calculate the area

of the piston required.

14. A door requires a force of 400 N to slide it open. A single-acting cylinder supplied

with a pressure of 5 bars controls the operation. Calculate the diameter of the

piston required to produce this force.

Use the formula:

AreaDiameter

4

15. A furnace door weighs 100 N and is lifted by a single-acting cylinder as it

outstrokes. Compressed air is supplied at a pressure of 4 bars. Calculate the

diameter of the piston required to raise the door.

Use the formula:

AreaDiameter

4

Page 65: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

63

Forces in a double-acting cylinder

We already know that a double-acting cylinder can be much more useful to us in

pneumatics because both the outstroke and instroke are controlled by compressed air.

This allows us to make use of both the outstroke and the instroke force. What we

learn, however, is that the outstroke force is greater than the instroke force. Why is

this the case?

During the outstroke, the compressed air pushes against the surface area of the piston

in the same way as in the single-acting cylinder.

Figure 81

However, during the instroke the surface area is reduced because of the piston rod.

This means that the compressed air does not have as big an area to push against and so

it does not produce as big a force.

Figure 82

We can find this surface area, or effective area as it is known, by calculating the area

of the piston rod and subtracting it from the surface area of the piston.

Effective area = piston area – piston rod area

Page 66: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 64

Worked example

A double-acting cylinder has a piston with a diameter of 25 mm. The piston rod is

5 mm in diameter. Pressure is supplied to the system at 4 N/mm2. Calculate the force

produced by the cylinder as it outstrokes and instrokes.

Step 1

Write down any information that you have from the question.

Pressure = 4 N/mm2

Piston diameter = 25 mm

Piston rod diameter = 5 mm

Step 2

We need to calculate the surface area.

2

2

2

mm491

4

2514.3

4

d

Area

Step 3

Use the correct formula for what you are trying to find. In this case, calculate the

outstroke force.

Force = Pressure Area

= 4 491

= 1964 N

Outstroke force = 1.96 kN

Step 4

Calculate the piston rod area.

2

2

2

mm20

4

514.3

4

d

arearodPiston

Step 5

Calculate the effective area. (We already know the piston area from step 2.)

2mm471

20491

arearodpistonareapistonareaEffective

Page 67: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

65

Step 6

Calculate the instroke force.

Force = Pressure Effective Area

= 4 471

= 1884 N

Instroke force = 1.88 kN

Page 68: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 66

Assignment 16

1. Explain why the forces produced by a double-acting cylinder on the outstroke and

instroke are different.

2. A double-acting cylinder found in a Technological Studies room has a piston

diameter of 20 mm and is supplied with air at a pressure of 0.3 N/mm2. What

force is produced as the piston outstrokes? The piston rod has a diameter of 6 mm.

What force is produced on the instroke?

3. A double-acting cylinder is used to raise and lower a barrier in a car park. The air

pressure is 0.4 N/mm2 and the piston has a diameter of 40 mm. The piston rod is

12 mm in diameter. What forces are produced when the piston outstrokes and

instrokes?

4. A double-acting cylinder is used to set up skittles in a bowling complex. An

instroking force of 0.04 kN is needed to move the skittles. The effective area of

the piston is 133 mm2.

(a) What pressure should be supplied to the cylinder?

(b) At this pressure, will the outstroke force be larger or smaller than the instroke?

Explain your answer.

5. Components on a conveyor system travel along and drop onto a table attached to

the end of a double-acting cylinder.

Figure 83

As the cylinder instrokes, the components are raised up and then pushed by

another cylinder on to the next conveyor. The piston diameter is 20 mm and air is

supplied at a pressure of 0.45 N/mm2. The effective area is 200 mm

2.

(a) Calculate the instroke force and say whether the system could lift a component

weighing 100 N.

(b) Someone suggests turning the double-acting cylinder round so that the

components are lifted by the outstroke.

Page 69: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

67

Figure 84

Is the system now able to raise the components? Explain your answer.

Page 70: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 68

Homework assignments

Homework 1

1. Describe some of the advantages of using pneumatics.

2. List the safety rules we must follow when operating pneumatic circuits.

Page 71: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

69

Homework 2

1. Which terms can be used to describe the piston in the position shown?

Figure 85

2. Name each of the following actuators.

Figure 86

Page 72: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 70

Homework 3

1. Draw the symbols for the following components.

(a) Push button, spring return 3/2 valve

(b) Single-acting cylinder

(c) Plunger-operated, spring return 3/2 valve

(d) Unidirectional restrictor

(e) Pilot air operated 5/2 valve

(f) Double-acting cylinder

2. Draw the symbols used to represent main air and exhaust.

Page 73: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

71

Homework 4

1. The diagrams below have a basic fault. Identify this fault and then redraw the

diagram properly.

(a)

Figure 87

(b)

Valve A Valve B

Figure 88

Page 74: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 72

Homework 5

1. What is the difference between a restrictor and a unidirectional restrictor?

2. Why do we restrict the exhaust air from a cylinder rather than the air entering the

cylinder?

3. Name the components used to create a time delay. Draw a diagram to show how

they are connected together.

4. How can we change the length of a delay?

Page 75: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

73

Homework 6

1. Describe the difference between a T-piece and a shuttle valve. You may use

sketches to help.

2. Name the following components and describe what they are used for.

a

..

.

b c

Figure 89

Page 76: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 74

Homework 7

1. A circuit allows a door to be opened by pressing either valve A or valve B. What

type of control is this?

2. Draw the truth table for this type of circuit.

3. How can AND control improve safety on a production line?

4. Draw a pneumatic circuit that would demonstrate AND control.

Page 77: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

75

Homework 8

1. What name is given to the movement produced by an automatic circuit?

2. What is the difference between a semi-automatic and a fully automatic circuit?

3. Explain why the force produced by the instroke of a double-acting cylinder is less

than the outstroke.

4. Safety barriers on a fairground ride are held in place by pneumatic cylinders.

Which type of cylinder would you recommend? Describe the reasons for your

choice.

Page 78: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 76

Homework 9

1. A double-acting cylinder is used to open and close a window in a greenhouse. The

window weighs 20 N and the piston diameter of the cylinder is 10 mm. What air

pressure should be supplied to this system? (Show all your working.)

2. A force of 280 N is needed to tip over a container full of rubbish. Compressed air

is supplied to the pneumatic system at a pressure of 0.7 N/mm2. What cylinder

diameter is needed to complete this task?

3. A pneumatic system is used to dip components into a chemical solution. It is no

problem for the cylinder to lower the components, but it is unable to raise them by

instroking. The components weigh 550 N and the cylinder has a diameter of

32 mm. The piston rod is 12 mm in diameter and air is supplied to the system at a

pressure of 0.7 N/mm2. Show by calculation why the system cannot lift the

components.

Page 79: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

77

Homework 10

1. A furniture manufacturer uses pneumatics to test wear and tear on drawer guides

in a kitchen unit. A double-acting cylinder is used to constantly open and close the

drawer, and the runners are checked regularly. The following pneumatic circuits

have been designed to carry out the same task. Describe how each circuit works

and choose the circuit that you think would best perform the task. Give reasons for

your choice.

DRAWER GUIDES

KITCHEN UNIT

DRAWER

PISTON MOVEMENT

X

Figure 90

Page 80: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 78

DRAWER GUIDES

KITCHEN UNIT

DRAWER

PISTON MOVEMENT

MICRO-SWITCH

12Vdc

12V

dc

Figure 91

The best circuit is

because

Page 81: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

79

Unit assessment

Hot plastic sheets are moulded into cups using a former attached to the end of a

double-acting cylinder. An operator starts the process by pressing a button, but the

cylinder should instroke automatically. Before this happens, there should be a delay to

allow the plastic sheet to cool and set in shape. A partly completed diagram is shown.

HOT PLASTICSHEET

Figure 92

(a) Complete the missing piping.

(b) State the full name of each of the pneumatic components marked on the

diagram.

1.

2.

3.

(c) Using appropriate terminology, explain how the circuit works.

Page 82: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 80

(d) The cylinder instrokes so quickly that sometimes the cup gets stuck onto the

former. Name the component that could be used to reduce the speed of the

cylinder.

(e) The component named in your answer to (d) can be inserted in the circuit

shown above so that the cylinder instrokes slowly. Add this component to the

circuit diagram at the appropriate point.

(f) Describe two ways of changing the length of time delay.

1.

2.

(g) It requires a force of 16 N to press the plastic sheet into shape. What air

pressure is required if the diameter of the piston is 10 mm. (Show all working

and units.)

[Pressure = Force/Area, Area = r2 = d

2/4]

Page 83: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

81

Page 84: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 82

Section 2: Electronic Control

There are many advantages in controlling pneumatic circuits with electronics. First,

electronic signals are faster than pneumatic signals, so circuits respond much more

quickly. We can also carry electrical signals over longer distances than pneumatic

signals. Finally, electronic components are much smaller than pneumatic actuators,

which can be bulky and interfere with the operation of a circuit.

If we control pneumatic circuits with electronics we can design complicated control

systems and still use pneumatic components for lifting and moving and all the things

that they do best.

To control a pneumatic circuit with electronics we need to use a solenoid-operated

valve.

Figure 93

This type of valve works in the same way as other 3/2 or 5/2 valves with the exception

that it is actuated by an electrical signal. This electrical signal can be produced by

many different components such as microswitches and reed switches. Reed switches

are useful if the cylinder has a magnetic piston band. This means that you can detect

the position of the piston without relying on a switch or button that needed to be

pressed.

Most solenoids are 8 V or 12 V devices. The voltage rating will be stamped or printed

onto the solenoid casing. You must always check this before you start work with

solenoids.

To find out more information about solenoids, you should look at video clips within

the Festo CD-ROM. In particular, you should view film numbers 8, 9 and 10.

In a bottling plant, a single-acting cylinder is used to press the lids onto the bottles. A

roller trip, spring return 3/2 valve is used to detect when the bottles are in the correct

position. Sometimes, however, the roller is not actuated and the bottles pass to the

next stage unsealed. Someone suggests that a microswitch be used instead to sense

when the bottles are in place.

Page 85: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

83

Figure 94

The circuit diagram would look like this:

V+

0 V

Figure 95

V+ will depend on the voltage rating of your solenoid. This will usually be 8 V or

12 V. You should check this before wiring your circuit.

To get the single-acting cylinder to outstroke, you press the microswitch. This

energises the solenoid valve and it changes state. The valve then allows air to flow

into the cylinder. Once the switch is released, the cylinder instrokes. It is important

that you do not keep the switch pressed for a long time as this can cause the solenoid

to overheat and be damaged.

Page 86: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 84

Assignment 17

1. Build and test the circuit shown for pressing the lids onto bottles.

(a) Record all the important information about this circuit, including a systems

diagram, a circuit diagram and an explanation of how the circuit works.

2. Describe the advantages of controlling a pneumatic circuit with electronics.

We can also make use of other electrical components such as temperature sensors,

light sensors and counters to control the state of a solenoid valve. In these circuits we

need to use a relay to drive the solenoid as the voltage rating is higher than that of our

electronic circuit.

A greenhouse uses a double-acting cylinder to open and close the windows. The

windows should open when it gets too hot and close when it gets too cold.

Figure 96

The circuit diagram to solve this problem is shown below.

POS

SIG

0V

NEG

RANGE+5V DC TO +8V

DC

+

S

0V

-

+

S

0V

-

E & L INSTRUMENTS Ltd

TP

+V

0V

0V

+

S

0V

-

+

S

0V

-

E & L INSTRUMENTS Ltd

TP

WITH

REF VOLT S

REF

INC

REF VOLT S

VREF

0V

MAGIC

THINGY

+

S

0V

-

+

S

0V

-

E & L INSTRUMENTS Ltd

TP

0v

0v

+V

0V

+

S

-0V

+

S

-

E & L INSTRUMENTS Ltd

Vs

Figure 97

Assignment 18

1. Build and test the circuit shown for opening and closing the window.

(a) Record all the important information about this circuit including a circuit

diagram and an explanation of how it works.

(b) The window opens and closes too quickly. Alter your circuit so that it moves

slowly.

Page 87: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

85

Page 88: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 86

Section 3: Programmable Control

To achieve really complex control of pneumatics, it is much easier and more reliable

to use a programmable system. One way is to use a microcontroller such as the Basic

Stamp.

Using this type of interface allows us to control the state of a solenoid valve. A

solenoid valve is actuated by a brief electrical signal and should only really be used

for signalling purposes. If the solenoid is energised for too long, the valve can

overheat and be permanently damaged.

Programmable control allows us to design sequences that are not possible with

pneumatic actuators, for example the sequence B+, A+, A, B. It also allows us to

control the action of a solenoid by more than one switch and this could be very useful

as part of a safety system. Exact time delays can be achieved too without the need for

components such as a flow control valve and a reservoir. The greatest advantage,

however, is that we can change the program at any time. In fact, we could have

several programs written and saved on disc ready to be used.

Let us look back at our car park problem.

Figure 98

Finally someone has suggested that the barrier should be controlled by a computerised

system as this will help to speed up the flow of traffic entering the car park, especially

when it is very busy. When cars approach the barrier, the car wheels will activate a

switch and the barrier will rise automatically. Once the car has passed under the

barrier, a second switch is pressed that lowers the barrier. The process is then ready to

begin again.

Page 89: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

87

The flow chart is shown below.

START

Barrier

down

Is approach

switch

pressed?

Barrier

up

Is ‘clear’

switch

pressed?

Yes

No

Yes

No

Figure 99

A PBasic program that would achieve this operation is:

init: let dirs = %11110000

main: low 7

check1:if pin0 = 1 then raise

goto check 1

raise:high 7

if pin1 = 1 then main

goto raise

end

To test this program you will need to download it to a stamp controller. You will also

need the input module and output driver module.

The input module allows us to connect switches and sensors to the stamp controller.

For this problem we need to connect two microswitches to the input module at pins 0

and 1.

Page 90: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems 88

The output driver allows the stamp controller to drive devices such as buzzers and

motors. In this problem it will be used to control a solenoid 3/2 valve.

The solenoid needs its own power supply to energise the coil. Most solenoids are 8 V

or 12 V devices and the casing of the component should tell you the voltage rating.

This voltage should be applied to the ‘driver power supply’ terminals at the top of the

board. You must also make sure that the slide switch is set to ‘External’. Finally,

connect the black wire from the solenoid to pin 7 and the red wire to the V+

connection.

V+

V+

7

6

5

4

RP1

STAMP EXTERNAL 0V V+

DRIVERPOWERSUPPLY

DARLINGTONDRIVER

SERVO

B

PUSHPULLDRIVER

A

B

0V

7

6

5

4

Red

Black

Power

supplySet switch to

External

Figure 100

Page 91: Pneumatics Notes

Standard Grade Technological Studies: Pneumatic Systems

89

The finished circuit should look like this.

Stamp

Controller

Output

Driver

Input

Module

0V V+

Figure 101

Assignment

1. Build and test the circuit shown.

a. Use a report sheet to record all the important information about this circuit.

b. Name two other types of input device that could be used to detect the cars.

State one advantage and disadvantage of each.

2. Sheet-metal drainage panels are shaped on a pneumatic press. The press uses two

single-acting cylinders, a T-piece and a 3/2 solenoid valve. The sequence must

only begin when the start switch has been pressed. The press is then held for three

seconds before being released. A buzzer must sound when the press is in

operation.

(a) Design a pneumatic circuit to solve this problem.

(b) Draw a flow chart.

(c) Write a PBasic program.

(d) Evaluate your solution. How well does it solve the problem? (You may need to

build your solution to check this.)

3. Modern trains have many built-in safety features. One feature is an automatic

brake system that is activated if the driver does not press a switch every 30

seconds. This is to ensure that the driver is alert throughout the journey. Five

seconds before the brakes are applied automatically, a warning buzzer sounds to

alert the driver that the switch needs to be pressed. Pressing the button at this stage

will reset the system. Large forces are needed to bring the train to a stop and

pneumatic cylinders are used to activate the brakes.

(a) Using two single-acting cylinders, a T-piece and a 3/2 solenoid valve, design a

pneumatic circuit that could be used to apply the brakes.

(b) Draw a flow chart of this problem.

(c) Write a PBasic program that would control the pneumatic circuit.

(d) Build and test your solution.

(e) Evaluate your solution. How well does it solve the problem?

(f) As the train approaches a station, the driver needs to apply the brakes to stop