PM5500 - Firmware Update (1)

3
 122 HRB1684301-01 Chapter 14!Maintenance and upgrades PowerLogic" PM5500 series user manual If the problem is not fixed after troubleshooting, contact Technical Support for help. Make sure you have your meter#s firmware version, model and serial number information available. Meter memory The meter uses its non-volatile memory (NVRAM) to retain all data and metering configuration values. Under the operating temperature range specified for the meter, the NVRAM has an anticipated life of 45 years or longer. The meter stores its data logs in a memory chip, which has a life expectancy of up to 20 years under the operating temperature range specified for the meter. Clock battery The internal battery in the meter keeps its clock running and helps maintain the time even when the meter is powered down. The life expectancy of the internal battery is estimated to be over 10 years at 25°C under typical operating conditions. Firmware version, model and serial number You can view the meter#s firmware version, model and serial number from the display panel or through the meter webpages: $ Using the display panel: Navigate to Maint > Diag > Info. See %Maintenance& on page 66 for details. $ Using the meter webpages: Navigate to Diagnostics > Meter . See %Diagnostics& on page 59 for details. Firmware upgrade To see if there are firmware upgrades available for your meter, search your meter at www.schneider-electric.com. NOTE: For MID compliance, the PM5561 meter#s firmware upgrade functionality is permanently disabled. Reasons for upgrading your meter#s firmware include the following: $ Improve meter performance (e.g., optimize processing speed) $ Enhance existing meter features and functions $  Add new functional ity to the met er $  Achieve comp liance to stric ter industry st andards The meter contains firmware that can be upgraded using the following methods: Meter firmware and upgrade method Firmware type Upgrade method Description OS DLF3000 The OS (operating system) firmware contains code that controls the meter#s features. Language DLF3000 The language file contains translation strings to set the meter#s display to the selected language.

Transcript of PM5500 - Firmware Update (1)

7/21/2019 PM5500 - Firmware Update (1)

http://slidepdf.com/reader/full/pm5500-firmware-update-1 1/3

122 HRB1684301-01

Chapter 14!Maintenance and upgrades PowerLogic" PM5500 series user manual

If the problem is not fixed after troubleshooting, contact Technical Support for help.

Make sure you have your meter#s firmware version, model and serial number

information available.

Meter memory

The meter uses its non-volatile memory (NVRAM) to retain all data and metering

configuration values. Under the operating temperature range specified for the meter,

the NVRAM has an anticipated life of 45 years or longer. The meter stores its data logs

in a memory chip, which has a life expectancy of up to 20 years under the operating

temperature range specified for the meter.

Clock battery

The internal battery in the meter keeps its clock running and helps maintain the time

even when the meter is powered down.

The life expectancy of the internal battery is estimated to be over 10 years at 25°C

under typical operating conditions.

Firmware version, model and serial number 

You can view the meter#s firmware version, model and serial number from the display

panel or through the meter webpages:

$ Using the display panel: Navigate to Maint > Diag > Info. See %Maintenance& on

page 66 for details.

$ Using the meter webpages: Navigate to Diagnostics > Meter . See %Diagnostics& on

page 59 for details.

Firmware upgrade

To see if there are firmware upgrades available for your meter, search your meter at

www.schneider-electric.com.

NOTE: For MID compliance, the PM5561 meter#s firmware upgrade functionality is

permanently disabled.

Reasons for upgrading your meter#s firmware include the following:

$ Improve meter performance (e.g., optimize processing speed)

$ Enhance existing meter features and functions

$  Add new functionality to the meter 

$  Achieve compliance to stricter industry standards

The meter contains firmware that can be upgraded using the following methods:

Meter firmware and upgrade method

Firmware type Upgrade method Description

OS DLF3000The OS (operating system) firmware contains code thatcontrols the meter#s features.

Language DLF3000The language file contains translation strings to set themeter#s display to the selected language.

7/21/2019 PM5500 - Firmware Update (1)

http://slidepdf.com/reader/full/pm5500-firmware-update-1 2/3

PowerLogic• PM5500 series user manual Chapter 14Maintenance and upgrades

HRB1684301-01 123

Using DLF300 to upgrade firmware

1. Download the latest version of DLF3000 from www.schneider-electric.com, then

install it on your computer.

NOTE: DLF3000 is a free Schneider Electric utility for downloading firmware to your

meter.

2. Download your meter!s firmware from www.schneider-electric.com.

3. Start DLF3000.

4. Click Add. Navigate to the folder where you saved your meter!s firmware.

5. Select the firmware file and click Open.

6. Select the firmware, then click Next.

7. If you haven!t defined an upgrade system yet:

• Click New, then type in the box to assign a system name

• Click Add, then type in the box to assign a communications connection name

• Select the communications driver (Modbus/TCP Driver or Serial Driver)

8. Click Continue.

9. If you are using Modbus over TCP to upgrade, type the meter!s IP address in the

box, then click OK.

10. Click Add Device.

• Type in the box to assign a device name

• Select the device type from the list

• Select the connection name, i.e., the one you defined in the previous step.

11. Click Next.

12. Make sure the connection name, i.e., the one you defined in the previous step, is

still selected. Enter the device address.

13. Select the protocol (e.g., Modbus).

14. Click OK.

15. Click Next.16. Select the device name from the Download Candidate Devices pane, then click

the right arrow button to move the selection to the Download Target Devices pane.

17. Select the meter firmware in the Firmware to field.

18. Click Next.

19. Click Health Check to confirm the meter is communicating. The Health Status

shows Passed to indicate successful communications.

20. Click Next.

FPGA app DLF3000The FPGA app (field programmable gate array application)firmware provides seamless transition between the meter!s

physical hardware and the firmware code.

Ethernet FTP

The Ethernet files control how the meter webpages aredisplayed. The files in the FW folder contains the code andinitialization files to run Ethernet communications. The wwwfolder contains the webpages and javascript files.

Meter firmware and upgrade method (Continued)

Firmware type Upgrade method Description

7/21/2019 PM5500 - Firmware Update (1)

http://slidepdf.com/reader/full/pm5500-firmware-update-1 3/3

124 HRB1684301-01

Chapter 14!Maintenance and upgrades PowerLogic" PM5500 series user manual

21. The Firmware Update Group shows the connection name, the firmware version and

status (should be #Queued$). The Group Device List shows the device or devices

being upgraded. Click Download.

NOTE: A warning message displays, #Warning: Relays on PowerLogic Metering

Devices will be de-energized if selected for download and will remain in this mode untila successful download is completed. Press OK to start the download.$

22. Click OK.

! The Firmware Upgrade Group status changes to Active, then updates to show

the current upgrade progress (in percent complete).

! The Group Device List status shows #Entering Download Mode$, then changes

to #Downloading$ when the firmware is being downloaded to the meter.

#Estimated Time Remaining$ shows the firmware download progress.

! You can also check the progress on meters equipped with a display panel. The

meter display shows #Download in progress$ and a shows a dynamically

incrementing number for #Percent Complete$ (up to 100%).

23. When the firmware upgrade is complete, the Firmware Update Group status shows

Complete (Passed). The Group Device List status shows Successful Download.Click Finished.

24. To exit the download firmware program, click Yes when prompted to quit DLF.

Upgrading the Ethernet card

The Ethernet card is the hardware component in your meter that is responsible for

Ethernet communications. The Ethernet files are contained in two folders: FW and

www:

& FW contains the code and other initialization files that run Ethernet

communications.

& www contains the webpages and java script files. You can add custom webpages or

modify the existing ones in this folder.

To upgrade your Ethernet card firmware, use an FTP client, such as FileZilla.

1. Start your FTP client.

2. Click Edit > Settings.

3. In the tree view, click Transfers > File Types.

4. Set Default transfer type to Binary, then click OK.

5. Type the meter's IP address in the Host field and log in using your credentials. The

factory default settings are:

! Username = user2

! Password = pass26. You may leave the Port field blank (the default FTP port setting is 21). Click

Quickconnect.

7. In the local site pane, navigate to the folder where you downloaded the

communications card firmware, then open the FW folder.

8. Navigate to the FW folder in the remote site pane (i.e., the meter).

9. Select all files in the FW folder from the local site, then upload it to the FW folder on

the remote site.

10. If prompted that the target file already exists, select or confirm to overwrite the

target file. Select Apply to current queue only if this option exists in the FTP client

you are using.

11. Repeat the previous file transfer steps, this time selecting all files in the www folder.