PLUMBER’S INSTALLATION Universal Close Coupled ...... · Universal Close Coupled Cistern...

1
Fig. 1 Issue No. 1 Date of issue: 03/11/17 Universal Close Coupled Cistern PLUMBER’S INSTALLATION INSTRUCTIONS PLEASE READ CAREFULLY BEFORE INSTALLATION THESE CISTERN INSTRUCTIONS SUPERSEDE INSTRUCTIONS IN THE PAN CARTON 22 mm projection from finished wall 1 /2 " B.S.P. Nipple Finished wall IMPORTANT TO ACHIEVE A SATISFACTORY 4.5/3L FLUSH PERFORMANCE AND A 4 STAR WATER EFFICIENCY RATING THE CISTERN MUST BE MATCHED WITH A COMPATIBLE 4.5/3L TOILET PAN. 240 Bottom inlet or overflow All measurements are subject to accepted manufacturing tolerances. To ensure accuracy please check actual product dimensions before drilling for installation. The manufacturer reserves the right to change specifications at any time without giving prior notification. This product should be installed by a qualified plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements. Fig. 4 Fig. 5 Note: For back inlet installations the working pressure minimum 30 kPa to maximum 1000 kPa flow pressure Stop Valve and Back Inlet Valve Detail Bottom Inlet Valve Detail Increase water level Decrease water level Cistern Stop Valve Increase water level Decrease water level CLOSE COUPLED CISTERN FIXING PROCEDURE Standard Right Hand Bottom Inlet Note: The inlet valve can be changed from right to left. The cistern fixes directly to the pan with a robust base fixing system without the need for wall fixing. 1- Securely attach the self-adhesive Foam Seal around the outlet on the base of cistern, as detailed in Fig. 2. Remove outlet valve to gain access to the cistern fixing holes. 2- Connect flexible hose to inlet valve and thread other end of flexible hose through side hole on pan, as detailed in Fig. 2. Position cistern onto pan and align the cistern fixing holes with the threaded fixing holes located in the cistern platform. Fit the seals onto the Winged Fixing Bolts. 3- Insert the Winged Fixing Bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 3. 4- Refit the outlet valve into position. 5- Flush the lines and connect water supply and check operation of cistern. 6- Adjust water level. Turn on water mains. Open the Cistern Stop Valve and check the operation of the mechanisms and valve. Adjust water level to the water level mark inside the cistern by simply turning the float arm adjustment screw in a clockwise or anti clockwise direction as detailed in Fig. 4. 7- Fit lid to check push button operation to complete installation. Back inlet installation 1- Securely attach the self-adhesive Foam Seal around the outlet on the base of cistern, as detailed in Fig. 2. Remove outlet valve to gain access to the cistern fixing holes. 2- Position cistern onto pan and align the cistern fixing holes with the threaded fixing holes located in the cistern platform. While lowering cistern onto pan, angle the top of the cistern away from the wall until the cut-out clears the connection nipple in the wall. Fit the seals onto the Winged Fixing Bolts. 3- Insert the Winged Fixing Bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 3. 4- Fit Cistern Stop Valve (supplied) to the ½" B.S.P. nipple in the wall using approved thread seal, in the downward angled position 45° to the right hand side, as detailed in Fig. 5. 5- Flush the lines before connecting the flexible hose to the Cistern Stop Valve and ensure the hose is not rubbing against the inside of the cistern. 6- Turn on water mains. Open Cistern Stop Valve and check for leaks and operation of mechanisms and valves. Ensure there is no leakage from the cistern into the pan. 7- Adjust water level to the 4.5 litre water level mark inside the cistern by simply turning the float arm screw in a clockwise or anti-clockwise direction as detailed in Fig. 5. 8- Fit cistern lid to check flush button operation to complete installation. 395 740 Centre of back inlet water connection 100 Setout position for 1 /2" B.S.P. Nipple Fig. 3 Foam Seal Winged Fixing Bolt seal Cistern Pan Captured nut toggle Fig. 2 Foam Seal position and Bottom Inlet Cistern Hose Fixing Back Inlet Cistern Fixing Inlet Valve Flexible hose Flexible hose Cistern Nut Foam Seal

Transcript of PLUMBER’S INSTALLATION Universal Close Coupled ...... · Universal Close Coupled Cistern...

Page 1: PLUMBER’S INSTALLATION Universal Close Coupled ...... · Universal Close Coupled Cistern PLUMBER’S INSTALLATION INSTRUCTIONS PLEASE READ CAREFULLY BEFORE INSTALLATION THESE CISTERN

Fig. 1

Issue No. 1Date of issue: 03/11/17

Universal Close Coupled Cistern

PLUMBER’S INSTALLATIONINSTRUCTIONS

PLEASE READ CAREFULLY BEFORE INSTALLATION THESE CISTERN INSTRUCTIONS SUPERSEDEINSTRUCTIONS IN THE PAN CARTON22 mm

projection fromfinished wall

1/2" B.S.P.Nipple

Finished wall

IMPORTANTTO ACHIEVE A SATISFACTORY 4.5/3L FLUSH PERFORMANCE AND A 4 STAR WATER EFFICIENCY RATING THE CISTERN MUST BE MATCHED WITH A COMPATIBLE 4.5/3L TOILET PAN.

240Bottominlet or

overflow

All measurements are subject to accepted manufacturing tolerances.To ensure accuracy please check actual product dimensions before drilling for installation.The manufacturer reserves the right to change specifications at any time without giving prior notification.This product should be installed by a qualified plumber. Local authority, Water Board, and BuildingRegulations may apply to the installation of this product, and you should consult the appropriate bodieson these requirements.

Fig. 4 Fig. 5

Note: For back inlet installations the workingpressure minimum 30 kPa to maximum1000 kPa flow pressure

Stop Valve and Back Inlet Valve Detail

Bottom Inlet Valve Detail

Increase water

level

Decrease waterlevelCistern

Stop ValveIncrease

water level

Decrease waterlevel

CLOSE COUPLED CISTERN FIXING PROCEDURE

Standard Right Hand Bottom InletNote: The inlet valve can be changed from right to left. The cistern fixes directly to the pan with a robust base fixing system without the need for wall fixing.

1- Securely attach the self-adhesive Foam Seal around the outlet on the base of cistern, as detailed in Fig. 2. Remove outlet valve to gain access to the cistern fixing holes.

2- Connect flexible hose to inlet valve and thread other end of flexible hose through side hole on pan, as detailed in Fig. 2. Position cistern onto pan and align the cistern fixing holes with the threaded fixing holes located in the cistern platform. Fit the seals onto the Winged Fixing Bolts.

3- Insert the Winged Fixing Bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 3.

4- Refit the outlet valve into position.5- Flush the lines and connect water supply and check operation of cistern.

6- Adjust water level. Turn on water mains. Open the Cistern Stop Valve and check the operation of the mechanisms and valve. Adjust water level to the water level mark inside the cistern by simply turning the float arm adjustment screw in a clockwise or anti clockwise direction as detailed in Fig. 4.

7- Fit lid to check push button operation to complete installation.

Back inlet installation

1- Securely attach the self-adhesive Foam Seal around the outlet on the base of cistern, as detailed in Fig. 2. Remove outlet valve to gain access to the cistern fixing holes.

2- Position cistern onto pan and align the cistern fixing holes with the threaded fixing holes located in the cistern platform. While lowering cistern onto pan, angle the top of the cistern away from the wall until the cut-out clears the connection nipple in the wall. Fit the seals onto the Winged Fixing Bolts.

3- Insert the Winged Fixing Bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 3.

4- Fit Cistern Stop Valve (supplied) to the ½" B.S.P. nipple in the wall using approved thread seal, in the downward angled position 45° to the right hand side, as detailed in Fig. 5.

5- Flush the lines before connecting the flexible hose to the Cistern Stop Valve and ensure the hose is not rubbing against the inside of the cistern.

6- Turn on water mains. Open Cistern Stop Valve and check for leaks and operation of mechanisms and valves. Ensure there is no leakage from the cistern into the pan.

7- Adjust water level to the 4.5 litre water level mark inside the cistern by simply turning the float arm screw in a clockwise or anti-clockwise direction as detailed in Fig. 5.

8- Fit cistern lid to check flush button operation to complete installation.

395

740

Cen

tre o

f bac

k in

let w

ater

con

nect

ion

100Setout position for 1/2" B.S.P. Nipple

Fig. 3

FoamSeal

WingedFixing Bolt

seal

Cistern

Pan Capturednut toggle

Fig. 2

Foam Seal position andBottom Inlet CisternHose Fixing

Back InletCistern Fixing

Inlet Valve

Flexible hose

Flexible hose

Cistern

Nut