PLCB4360A5AAMA - ProLogium · Doc.60105 4.35V- AP05-190104 PLCB4360A5AAMA 2D Drawing Unit: mm...

2
Doc.60105 4.35V- AP05-190104 PLCB4360A5AAMA Rechargeable Lithium-Ceramic Battery Ultra-Safe Wide Temp. Window (Operation/Storage) Fast Charge and Discharge Benefits Ultra-Safe : Hazard Level1~3 passed High Stability -Able to be charged at 85°C and discharged at 90°C. Key features Ultra-Safe. -No fire, no smoke and no leakage after physical impact. -Hazard Level 1~3 passed. High Stability (Storage) -Storage at 85°C/14 days, recovery > 98%, Swelling ratio <10%. -Storage at -105°C/14 days. (@3.8V~4.0V) -Storage at -40°C/ 3months, recovery > 98%. No salt out. -Storage at -65°C/1 month, recovery > 98%. No salt out. High Stability (Operation) -Able to be charged at 85°C -Able to be discharged at 90°C. 2C Discharge Rate Capability : -Capacity ~84% @ 25°C -Capacity ~93% @ 85°C Main applications Industrial / Rugged Tablet, Smart Helmet Medical Tablet, AIO PC, Wearable Device Handheld Device/ Power Bank Transportation and storage: Store in a dry place at a temperature preferably not exceeding 30°C. For long-term storage, keep the battery within a (30 ± 15) % state of charge. Electrical characteristics Nominal capacity 1950 mAh Nominal voltage 3.75 V Operating voltage 4.35~2.75V Energy Density 300 Wh/L Mechanical characteristics Thickness (max) 4.5 mm Width (max) 60 mm Length (max) 105 mm (without terminal) Typical weight 59.5 g Operating conditions Standard charge CC-CV (Constant Current & Constant Voltage) Current 0.2CmA/ Voltage 4.35V Cut-off current: 0.05C Max charge current* 1CmA Standard discharge CC (Constant Current) Current 0.2CmA Cut-off voltage: 2.75V Max discharge current* 1CmA Operation window** – 20°C to + 60°C * Consult ProLogium for increasing charging/discharging current. ** Consult ProLogium for optimized charging below -20°C

Transcript of PLCB4360A5AAMA - ProLogium · Doc.60105 4.35V- AP05-190104 PLCB4360A5AAMA 2D Drawing Unit: mm...

Doc.60105 4.35V- AP05-190104

PLCB4360A5AAMA Rechargeable Lithium-Ceramic Battery

Ultra-Safe

Wide Temp. Window (Operation/Storage)

Fast Charge and Discharge

Benefits

Ultra-Safe : Hazard Level1~3 passed

High Stability -Able to be charged at 85°C and discharged at 90°C.

Key features Ultra-Safe.

-No fire, no smoke and no leakage after physical impact. -Hazard Level 1~3 passed.

High Stability (Storage) -Storage at 85°C/14 days, recovery > 98%, Swelling ratio <10%.

-Storage at -105°C/14 days. (@3.8V~4.0V) -Storage at -40°C/ 3months,

recovery > 98%. No salt out. -Storage at -65°C/1 month, recovery > 98%. No salt out.

High Stability (Operation) -Able to be charged at 85°C -Able to be discharged at 90°C.

2C Discharge Rate Capability :

-Capacity ~84% @ 25°C

-Capacity ~93% @ 85°C

Main applications

Industrial / Rugged Tablet, Smart Helmet Medical Tablet, AIO PC, Wearable Device Handheld Device/ Power Bank

Transportation and storage: Store in a dry place at a temperature

preferably not exceeding 30°C. For long-term storage, keep the battery within a (30 ± 15) % state of charge.

Electrical characteristics

Nominal capacity 1950 mAh

Nominal voltage 3.75 V

Operating voltage 4.35~2.75V

Energy Density 300 Wh/L

Mechanical characteristics

Thickness (max) 4.5 mm

Width (max) 60 mm

Length (max) 105 mm (without terminal)

Typical weight 59.5 g

Operating conditions

Standard charge CC-CV (Constant Current & Constant Voltage)

Current 0.2CmA/ Voltage 4.35V

Cut-off current: 0.05C

Max charge current* 1CmA

Standard discharge CC (Constant Current)

Current 0.2CmA

Cut-off voltage: 2.75V

Max discharge current* 1CmA

Operation window** – 20°C to + 60°C

* Consult ProLogium for increasing charging/discharging current.

** Consult ProLogium for optimized charging below -20°C

Doc.60105 4.35V- AP05-190104

PLCB4360A5AAMA 2D Drawing

Unit: mm Tolerances: ±0.5mm

When handling ProLogium batteries: Do not throw the battery into fire, nor heat. Do not disassemble nor modify. Do not leave in a place of ≥60°C. Prevent from water or moisture. Do not add strong shock, nor drop. Do not solder lead directly to battery body. Do not short + and – terminals with metal.

Do not charge beyond the condition which described on the delivery specification.

Do not inverse charge.

Typical characteristics:

Discharge Profiles (0.2/0.5/0.75/1/1.5/2C Rate)

Operation Temperature Test (-20°C to +60°C)

Cycle Life Test

*charge/discharge/cycle tests criteria: @room temp. ( 25℃)

2,750

2,950

3,150

3,350

3,550

3,750

3,950

4,150

4,350

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Voltage (mV)

Capacity Ratio

0.2C CC/CV charge to 4.35V, cut off 0.05C

0.2C/0.5C/0.75C/1C/1.5C/2C discharge from 4.35V to 2.75V

0.2C Discharge

0.5C Discharge

0.75C Discharge

1C Discharge

1.5C Discharge

2C Discharge

2,750

2,950

3,150

3,350

3,550

3,750

3,950

4,150

4,350

4,550

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Voltage (mV)

Capacity Ratio

0.2C CC/CV charge to 4.35V, cut off 0.05C 25℃

0.2C discharge from 4.35V to 2.75V @ Test Temp.

60℃

45℃

25℃

10℃

0℃

-10℃

-20℃

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0 50 100 150 200 250 300 350 400 450 500

Retention

Cycle

0.5C CC/CV charge to 4.35V, cut off 0.05C, rest 15min

0.5C discharge to 3.0V, rest 15min

0.5C Cycle Life

Charge/Discharge Profile

2,750

2,950

3,150

3,350

3,550

3,750

3,950

4,150

4,350

4,550

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

Voltage (mV)

Capacity Ratio

0.2C CC/CV charge to 4.35V, cut off 0.05C0.2C discharge from 4.35V to 2.75V

0.2C Charge

0.2C Discharge