Trouble- shooting Before Using How to Use Maintenance AIR PURIFIER <Desktop type> MODEL MA-EF503HS-U MA-EF303HS-U INSTRUCTION MANUAL Features Plasma deodorization For odors that cannot be removed even with activated charcoal HEPA dust filtration Sensors to detect dust particles, pollen, and odors Powerful and quiet Hand-held remote control CONTENTS Page ¡Safety precautions ..........................2 ¡Precautions .....................................4 ¡Names and functions of parts .........5 ¡Effective usage................................7 ¡Preparations....................................8 Setting the filters Installing the batteries for remote controller ¡Operation (viewing the monitor lamps) ....9 ¡Changing the airflow .....................10 ¡Plasma air deodorization ..............11 ¡Off TIMER operation .....................11 ¡Monthly cleaning ...........................12 ¡Yearly cleaning ..............................13 ¡Replacing the filters ......................14 ¡Troubleshooting .............................15 ¡Specifications ...............(back cover) In order to ensure correct usage, please read this instruction manual carefully, and retain it for future reference.

Transcript of Plasma Pure Air Purifier For Residential HVAC l Libertyville l Chicago l Northshore

Trouble-shooting

Before

Using

Howto

UseMaintenance

AIR PURIFIER<Desktop type>

MODEL

MA-EF503HS-UMA-EF303HS-UINSTRUCTION MANUAL

Features● Plasma deodorization

For odors that cannot be removed even withactivated charcoal

● HEPA dust filtration● Sensors to detect dust particles,

pollen, and odors● Powerful and quiet● Hand-held remote control

CONTENTS Page

¡Safety precautions ..........................2¡Precautions .....................................4¡Names and functions of parts .........5¡Effective usage................................7¡Preparations....................................8

Setting the filtersInstalling the batteries for remote controller

¡Operation (viewing the monitor lamps)....9¡Changing the airflow .....................10¡Plasma air deodorization ..............11¡Off TIMER operation .....................11

¡Monthly cleaning ...........................12¡Yearly cleaning..............................13¡Replacing the filters ......................14

¡Troubleshooting.............................15¡Specifications ...............(back cover)

In order to ensure correct usage, please read thisinstruction manual carefully, and retain it for futurereference.

AC120V

WARNING

CAUTION

WARNING

Safety precautionsThe following displays categorize the degree of danger when mishandled.

Possibility of serious injury and even death, if mishandled.

Possibility of injury and damage to household furniture and surroundings.

The following symbols are defined as follows:

Prohibited Do not touchDo not usenear waterDo not

disassemble Do not get wet

Always follow

Remove thepower plug

Fire and/or electrical shockmay occur as a result.For repair, contact your dealer ofpurchase or Mitsubishi Electric.

Do not repair,disassemble or modify.

Do not damage the power cord.● Do not coat or bundle.● Do not place objects on top of

the cord.● Do not remove the power plug by

pulling on the cord.

Fire, electrical shock, and/ordamage may occur as a result.

Do not use damaged power cordor plug. Do not use damagedpower outlet where the plugcannot be inserted securely.

Electrical shock, short circuitand/or fire may occur as aresult.

Do not wash the Plasmaunit.

Using the Plasma unit when wet may cause fire and/orelectrical shock.

Do not insert finger orforeign objects into thedust sensor.

Electrical shock may occur asa result.

Remove the power plugwhen cleaning.Furthermore, never handle thepower plug with wet hands orget the plug wet.

Electrical shock and/or injurymay occur as a result.

Use an AC120V power outlet.

Electrical shock, short circuitand/or fire may occur as aresult.

Periodically remove dustfrom the power plug with adry cloth.

Dust build-up can cause badinsulation and a fire may occuras a result.

2

To reduce the risk of electricshock, this equipment has apolarized plug (one blade iswider than the other). This plugwill fit in a polarized outlet onlyone way. If the plug does not fitfully in the outlet, reverse theplug. If it still does not fit,contact qualified personnel toinstall the proper outlet. Do notalter the plug in any way.

CAUTION

Gas Gas

Gas

Oil Oil

Oil

Spra

y

Before

Using

3

Do not allow the unit to intakeflammable gases.Do not use where there isaccumulation of such flammablegases (factories, hair salons, etc.).

Explosion and/or fire mayoccur as a result.

Do not install in a locationsuch as a bathroom where theunit may get wet, and avoidplaces with high humidity.

Electrical shock and/ormalfunction may occur as a result.If the unit gets wet for some reason,stop operation, remove the powerplug and contact your dealer ofpurchase or Mitsubishi Electric &Electronics USA, Inc..

Do not use in a locationwhere there is lampsmoke,such as from machine oil,etc.

The unit may crack, resulting inelectrical shock and/ormalfunction.

Do not insert fingers or foreignobjects into the intake grill, theexhaust air port, or any smallopenings of the unit interior.

Electrical shock, malfunctionand/or injury may occur as a result.

Do not wipe with benzene orpaint thinner, and do not sprayinsecticides or deodorizers,etc., onto the unit.

Electrical shock, fire and/orcracking may occur as a result.

Do not remove the HEPAfilter with the unit laying onits back.

Dust may enter inside the unit,and fire and/or electricalshock may occur as a result.

Do not use damaged filters, oroperate the unit without a filter.Contact your dealer or MitsubishiElectric for a replacement.

Fire and/or electrical shockmay occur as a result.

Do not touch the electricpoles of the Plasma unit.

Injury may occur as a result.

Ventilate periodically whenusing the unit with aheating appliance, etc.

Insufficient ventilation maycause CO intoxication.

● Do not use rechargeable batteries.● Make sure that the and are correctly aligned.● When replacing, always replace batteries at the same time using

the same type.● If the electrolyte from the alkaline batteries comes into contact with

skin, wash thoroughly with water. If the electrolyte accidentallyenters your eye, flush with water and seek immediate medicalattention.

Remove the power plugwhen not using for anextended period of time.

Insulation may deteriorate,causing short circuit, fire and/orelectrical shock as a result.

Use the batteries correctly by following the items below.

Injury and/or malfunction may occur if mishandled.

Safety precautions

4

PrecautionsThis air purifier is for household use only. Do not use for business purposes.

Do not block the intake grill orthe exhaust air ports.

Malfunction may occur as a result.

Do not use if the unit is layingon its back or front.

Malfunction may occur as a result.

Do not use with the intakegrill, the filters or the Plasmaunit removed.

Malfunction may occur as a result.

Do not use the unit as aventilation fan or range hood.

This may drastically reduce theservice life of the filter as well ascause deformation, discolorationand/or malfunction.

If the remote controller comes into contact with aliquid, remove batteries and dry thoroughly.

If the remote controller becomes inoperable, contact your dealerof purchase or Mitsubishi Electric.

Take note of the following when installing the unitDo not install near or on top ofhot objects, such as a stove,etc.

Malfunction, deformation and/ordiscoloration may occur as a result.

Keep unit at least 3.3 feet (1m) away fromtelevisions, cordless telephones, airconditioners, computers, incandescentbulbs, fluorescent lighting, etc.

Electrical wave interference mayoccur, resulting in the remotecontrol becoming inoperable.

Do not use in a locationexposed to direct sunlight

Deformation and/or discolorationmay occur as a result.

Leave space around the unit

Walls and/or ceiling may becomedirty as a result.

2 feet (60 cm) or more above the unit and 0.7feet (20 cm) or more on the sides and back.

2 feet (60 cm)or more0.7 feet

(20 cm)or more

When carryingTurn the power switch to OFF,unplug the unit, and carry theunit by the handle.

Do not press strongly againstthe control panel when carrying.

Notes

How strong are the electromagnetic waves discharged by this air purifier?The electromagnetic waves produced by this product are lower than mobile phones, and are harmless to the bodyand medical equipment.

Can the unit remove odors of newly constructed houses?The unit may not be able to completely remove odors if the discharge of odors is too much such as with new paint orcarpet glues.

0.7 feet (20 cm)or more

0.7 feet (20 cm)or more

6~7

Main unit Accessories

Control panel

Before

Using

5

Names and functions of parts

Odor sensorDetects smell of cigarettes, etc.

Reset SwitchPress after replacing the filter.

Activated charcoal filter

Remote controller

Two AA typebatteries for theremote controller

Plasma unit

HEPA filter

Intake grill

Dust sensorDetects polluted air suchas pollen, etc.

Grill-release buttonPress to remove the grill.(On each side of unit)

Table stand

Air fan

Spring clips(On each sideof Plasma unit)

What is a HEPA filter?

<High Efficiency Particulate Air filter>The HEPA filter is a high performance filterthan can catch up to 99.97% of all particlesas small as 0.3 micron in diameter.

Handle

Exhaust airport

Power cord

<Removing>Lay the unit on its backside, and then remove thestand by pressing tablestand tabs.

<Replacing>Hook the tabs on the frontside of the table stand,and then press in the rearside of the stand.

Precautions

Nam

es and functions of parts

6~7

Removing and replacing the unit table stand

PLASMA

REPLACE FILTER

Control panel

Plasma deodorization lampON… Plasma deodorization in

processFlashing…Error 13

Odor sensor

Filter replacement lampWhen lit, it indicates that the filters should be replaced.

Remote sensor

How to use the remote controller 9

14

Plasma air deodorization 11

Viewing the monitor lamps 9

Odor monitor (odor sensor)Shows the level of air pollution caused by odor of cigarette smoke, etc.Microdust Monitor (dust sensor)Displays the level of air pollution caused by tinyparticles such as cigarette smoke, etc.Pollen Monitor (dust sensor)Displays the level of air pollution caused bylarge particles such as pollen, dead mites,dust, etc.

ODORMICRODUST POLLEN

How do the sensors work?Odor sensorUsing a semiconductor sensor, gases from odor ingredients are detected. The sensor will react to a breeze from air conditioners, fans, etc., as well as odorless gases and perfumes.

Dust sensor¡MICRODUST

Using an optical sensor, the number of particles less than approximately 1 micron is detected.

¡POLLENUsing an optical sensor, the number of particles more than approximately 1 micron is detected.

About microdust and pollen

100 (micron)1010.10.01

Pollen

Feces or dead body of mites, dust

Small particles of cigarette smoke

Dusts which are harmful to the lungs

MICRODUSTSmall particles such cigarette smoke, etc.(Mainly particles smaller than 1 micron)

POLLENLarge particles such as pollen, dead mites, etc.(Mainly particles of larger than 1 micron)

Replacing the filters

6

Names and functions of parts (continued)

Before

Using

7

TIMER FAN AUTO

NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX

POWERON/OFF

11 1010

15 15

Off TIMER lamps Show the remaining operation time (hours).

Off TIMER button¡Switches the timer ON¡Switches the timer OFF

Off TIMER operation

Changing the airflow

FAN level indicatorON: The fan level in operation is displayed.Flashing: Error

FAN button¡Switches operation modes

and airflow volume

Changing the airflow

Operation mode lampsPOLLEN GUARD lamp ON: Pollen guard in progressNORMAL lamp ON: Normal operation in progressFlashing: Error

AUTO buttonSwitches operation modes

POWER button¡Turns the unit ON¡Turns the unit OFF

9Operation

POWER

AUTO FAN

PLASMA TIMER

Remote control operation panel

1111

10Operation mode button¡Switches operation modes.

Plasma air deodorization switch (on the remote only)¡Plasma air deodorization

function ON¡Plasma air deodorization

function OFF

9

Operation switch¡Turns the unit ON¡Turns the unit OFF

Off TIMER switch¡Switches the timer ON¡Switches the timer OFF N

ames and functions of parts

Effective usage

10

Use by installing on a high platform

Table-top POLLEN GUARD operationPOLLEN GUARD, which reacts to even the slightest traces of pollen, is recommended.Since scattered dust and pollen fall gradually, install the unit in a low location for the best result.Running the unit all day is also recommended if you are concerned about pollen.

Since cigarette smoke rises directly upward, installing the unit in a high location is recommended such as on a counter or dresser.(Take caution so that the unit does not fall.)

Effective usageFor the best results from your product, install the unit where there is good aircirculation.

If you areconcernedaboutsmoke

If you areconcernedaboutpollen

1

3

2

4

512~13

+�

-�

+�

-�

1

2

3

Caution

8

PreparationSetting the filtersRemove the plastics from the HEPA filter and theactivated charcoal filter before use.

Press the grill-release buttons, andthen remove the intake grill.

Remove the HEPA filter.

Both sides

Remove the Plasma unit.

Hold the springclips, and removeone side at a time. Hold with both

hands, and pullto remove.

Install the activated charcoal filter.

Remove theplastic beforeinstalling.

Replace the Plasma unit, the HEPAfilter, and the intake grill.

Removethe plastic

(White particles within the activatedcharcoal filter are titanium oxide, notmildew.)

Installing the batteries forthe remote controller

While pushing the cover, slide itforward.

Insert the batteries.

Close the cover by sliding it backwarduntil it snaps shut.

Two AA type batteries

● Ensure that the proper polarity is observed.

Use dry cell batteries in a proper manner.● Do not use rechargeable batteries.● Make sure that the positive and negative poles

are correctly aligned.● When replacing, always replace with two new

batteries of the same type.● Should your skin come in contact with the

electrolyte of the alkaline dry cell batteries,wash the affected area with water. Should theelectrolyte enter your eye, immediately contacta doctor.

Wrong use may cause injury or malfunction.

Before

Using

9

Preparation

Operation

TIMER FAN AUTO

NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX

POWERON/OFF

beep, beep beep, beeepPOWERON/OFF

AUTO FAN

PLASMA TIMER

POWERPOWER

ODORMICRODUST POLLEN

OperationOn the main unit

Press the power button on the main unit to turn on theair purifier.

● Each time you press this button, the unit turns ONor OFF.

● Both the operation mode lamp and the monitorlamp must be ON.

● When you plug in the power cord, the monitorlamps blink for approximately two minutes whilethe sensors stabilize.

Viewing the monitor lampsThe lamps light up (four levels) depending on amount of air contaminants or odors present.

Dirty airClean airMIN

FAN SPEEDMAX

Using the remote controller

Press the power button on the remote controllerto turn on the air purifier. The operation is thesame as on the main unit.

ON OFF Press

PressHow to use the remote controller

The remote controller allows you to operate the unitfrom a remote place.

Aim the remote controller toward the main unit and press the switch. The maximum range ofoperation is 23 feet (7 m). Remote sensor

Remote controller

● Do not cover the remote sensor with cloths, etc.

● If the main unit does not respond properly to thesignals from the remote controller, replace withthe new batteries.

● Make sure the remote sensor and the remotecontroller are in sight of one another.

Remote controller operation may not be possible inthe following situations:● In areas where the unit is subjected to direct sunlight.

The infrared rays of the sunlight may effect the remotesensor on the unit

● In rooms with inverter lighting for lower power consumption.The noise from the inverter lighting may effect the remotesensor on the unit.

Howto

Use

TIMER FAN AUTO

NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX

POWERON/OFF

FAN AUTOAUTO FAN

MIN LOW MED HIGH MAX

NORMALPOLLENGUARD

AUTO FAN

PLASMA TIMER

POWER

beep

beep

beep

10

Changing the airflow

On the main unit Using the remote controllerYou can select between FAN (manual) and AUTO operation modes.

You can select from 5 airflow volumes or AUTO.

Pressone of the buttons

You can select the airflow volume from theremote controller. The operation is the same aswith the main unit.

Pressone of the buttons

FANYou can selectfrom 5 airflowvolumes.

● The airflow changes each timethe button is pressed, and thelamp of the chosen volume lightsup.

AUTOYou can selectfrom POLLENGUARD andNORMAL.

● Operation switches every timethe button is pressed, and theselected operation mode lamplights.

● Operation is automaticallyadjusted to the appropriateairflow volume according to theodor monitor, microdust monitor,and pollen monitor.

■ POLLEN GUARD● The sensor is set to

supersensitive to react to even theslightest traces of pollen.

● The fan speed is faster than theNORMAL operation for easierintake of large particles such aspollen, etc.

■ NORMAL● The level of air pollution in the

room is monitored using the odorand dust sensors, and theappropriate airflow volume isautomatically selected.

● When the air is clean, the fan willstop.

■ MIN or LOWWhen sleeping

■ HIGH or MAXWhen house cleaning

● The unit will return to the previously set mode even after turning the unit off.The unit will return to the previously set mode even when reinserting the power plug or after having a power failure.

TIMER FAN AUTO

NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX

POWERON/OFF

AUTO FAN

PLASMA TIMER

POWER

AUTO FAN

PLASMA TIMER

POWER

PLASMA

beep beeep

TIMER

TIMER

beep beep beepbeeep

HOURContinuousOperation(Lamp off)

Howto

Use

11

Plasma air deodorizationThe unit uses the odor sensor to monitor the level of air pollution, then automatically activates the Plasma to break up odor ingredients in the air.

Using the remote controllerYou can turn the Plasma deodorization function ON or OFF.

● Each time you press this button, the Plasma unitturns ON or OFF.

● Turn the Plasma deodorization lamp ON.● The unit will return to the previously set operation

mode when power is interrupted.

● Since the unit operates intermittently during thePlasma deodorization, a hissing noise may beheard, and the unit may also stop at times. Ifthe noise becomes irritating, turn off the featureby pressing the PLASMA button on the remotecontrol.

● When the Plasma deodorization lamp isblinking, turn the unit off, and clean the Plasmaunit.

To operate from the main unit, you can turn thePlasma deodorization ON or OFF using thefollowing procedure:● When the power is turned on, press and hold

the AUTO button, and press the POWERswitch.

Off TIMER operationOn the main unit

You can set the unit so that it turns off after runningfor a preset time. (1, 2, 4 hours)

Using the remote controller

You can also use the remote controller toset/deactivate the off TIMER. The operation is thesame as on the main unit.

● The selected Off TIMER lamp lights.● The Off TIMER lamp will display the remaining

operation time and will switch as time passes.

● The remaining operation time can be changed.

Changing the airflow

Plasm

a air deodorization/Off tim

er operation

ON OFF

Press

Press

Press

13

1

2

3

4

14

Direction of

airflow

12

Maintenance

Monthly cleaning

For the best performance from your unit, clean approximately once a month.

Both sides

Using the softnozzle brush of avacuum cleaner,

Cleaning the sensors Cleaning the HEPA filter

Odor sensor (control panel)

Remove dust usingthe nozzle of avacuum cleaner.

Remove surrounding dustusing the nozzle brush of avacuum cleaner.

Dust sensor surroundings

Cleaning the main unit

Intake grillRemove dustusing a nozzlebrush of avacuum cleaner.

For stubborn dirt, removethe intake grill, and washwith a soft sponge.Thoroughly dry beforereplacing.

Main unit

Dry-wipe witha soft cloth.

For stubborn dirt,wipe with a clothdampened withwater.

Press the grill release buttons oneach side, and remove the intake grill.

Remove the HEPA filter and clean.

Replace the HEPA filter.

remove dust by taking care notto tear the HEPA filter surface.

Do not wash. The filter cannotbe reused if washed or afterbecoming wet.

8

Replace the intake grill.

Hook the five tabs on the upperside of the intake grill, and pressin the lower side until the releasebuttons snap securely.

Replace the HEPA filter with the logo facing you and

arrows pointing away from you.

Cleaning Sensors, the HEPAfilter, and main unit

Cleaning the Plasma unit

Monthly

YearlyReplacing the filters

WARNINGBefore cleaning the unit,turn off the power andremove the power plug.Electrical shock and/or injurymay occur as a result.

1

4

5

2

3

1

3

2

13

Maintenance

WARNINGBefore cleaning the unit, turn off the power andremove the power plug.Electrical shock and/or injury may occur as a result.

Yearly cleaningClean at least once a year. Clean the Plasma unit if the Plasma deodorization lamp flashes.

Cleaning the dust sensor

Remove the cover by depressingthe cover spring.

Left side ofmain unit

Clean the sensor lenses.

Use a dry cotton swaband clean the two lenses.

Replace the cover.

Press the grill release buttons oneach side; remove the intake grill,and then remove the HEPA filter.

Remove the Plasma unit.

Cleaning the Plasma unit

Plasma unit

Do not pull by force. Malfunctionmay occur as a result.

Clean the Plasma unit.

Lightly flick off the tips. Using force maycause the Plasma unit to deform,resulting in malfunction of the unit.

Use a toothbrush, and lightly flickoff the tips of the electric poles.

Replace the Plasma unit.

Position the Plasma unit usingboth hands, and press in eachspring clip until you hear a click.

Push inthe lowersection.

Replace the HEPA filter and theintake grill.

Hold the springclips, and removeone side at a time.Pull the Plasma unittowards you toremove.

Monthly cleaning

Yearly cleaning

8

Please replace the HEPA filter and the activated charcoal filter with new filters when the color on the surface of the HEPA filter matches the color indicated above.

Available from Mitsubishi Electric www.plasmapure.com

REPLACE FILTERS

Reset Switch

1

2

3

4

5

6

Reset switch

Beep

14

Use a ball point pen,or a similar pointedobject, and pressuntil a beep is heard.

Maintenance (continued)

Replacing the filters

The filter replacement lamp notifies you of the replacement period of the HEPA filter and the activated charcoal filter. Replace both the HEPA filter and the activated charcoal filter at the same time.

Replacement period

Color of household dust

Color of cigarette ingredients

● The service life of the filters varies dependingon the usage environment, and conditions.

● The HEPA filter and the activated charcoal filtercannot be reused. Always replace old filterswith new filters.

● When smoking large amount of cigarettes, odormay adhere to the filter and main unit. In thiscase, clean the main unit, and replace the filters.

Separately sold part:

Replacement filter set(HEPA filter/activated charcoal filter)

Model MAPR-E837HFTCode no. 5D4 C06

To order parts, contact your dealer of purchaseor Mitsubishi Electric @ www.plasmapure.com

Remove the intake grill and theHEPA filter.

Remove the Plasma unit.

Replace the activated charcoalfilter.

Replace the Plasma unit andmount a new HEPA filter.

Insert the power plug and pressthe Reset Switch.

Set vertically.(There is no front or back.)

Replace the intake grill.

12~13

Although the replacement period depends onthe usage environment and conditions, thelamp will light after approximately 5 yearswhen using the unit on constant MIN fanspeed.(In the case of MAX, the lamp will light inapproximately 1/4 the time.)

● When the filter replacement lamp illuminates

● When the HEPA filter becomes dirty and thecolor is about the same as that indicated onthe label

Press the power switch and turn on the power.

Reinsert the power plug into the power outlet.

Clean the sensors.

Replace the HEPA filter and the activated charcoal filter.

Clean the sensors.

Replace the HEPA filter and the activated charcoal filter.

Clean the Plasma unit.

Reset the intake grill, the HEPA filter and the activated charcoal filter.

Replace with new batteries, or correctly set the batteries observing the proper polarity.

12~13

14

14

8

13

8

Symptom Cause Remedy

Symptom Cause

The odor monitor does not change even when an odor can be noticed

The sensitivity of the sensor differs depending on odor ingredients, and the monitor display may at times remain unchanged.

● The following symptoms are not malfunctions.

Should the problem persist after having checked the above list, stop using the unit, remove the power plug and contact your dealer of purchase or Mitsubishi Electric.

There is no air intake

Odor and smoke are not completely removed

Is the fan level lamp on?(Is the power on?)

Is the power plug securely inserted into the power outlet?

Are the sensors dusty?

During the Plasma deodorization, you may hear a small hissing noise or notice an ozone smell.(The level of noise and degree of the smell of ozone will vary depending on the environment. The generated ozone is of low concentration and is harmless to the body.)

The monitors do not change much(Odor monitor, microdust monitor and pollen monitor)

Is the room too large?Use the unit within the range of the applicable floor area.

Checking monitor operation:● Rub tissue paper in front

of the main unit to discharge dust.

● Blow cigarette smoke.If there is a large volume of dust or odor, it may take some time for the air to become clean.

The monitor lamp flashes The monitor lamp will flash until the sensors become stable, even if the power is turned on immediately after inserting the power plug.

The monitor lamp flashes even when the room is clean

The sensor may at times respond to a breeze from air conditioners within the room, and gases that are unnoticeable to the human smell.

Is the unit operating in AUTO (NORMAL) mode?The unit will stop operation when the air is clean.

Are the sensors dusty?

Fan noise and vibration are louder than before

Plasma deodorization lamp flashes

There is an abnormal electrical discharge.

Is the activated charcoal filter still wrapped in plastic?

One of the following lamps flash:FAN/POLLEN GUARD/NORMAL

Are the intake grill, the HEPA filter and the activated charcoal filter properly set?

The remote controller does not work

Main unit vibrates heavily

Little monitor response

Is the unit installed on an unstable or unlevel surface? Install on a level and stable surface.

Is the HEPA filter or the activated charcoal filter dirty?

12~13

Is the HEPA filter or the activated charcoal filter dirty?

Remove the plastic and replace.

Have the batteries been completely depleted or are the and of the batteries set correctly?

The air fan does not turn, or there is no air discharge

A small hissing noise is heard, or there is a smell of ozone during the Plasma deodorization

Trouble-shooting

15

Maintenance

Troubleshooting

Replacing the filters

Troubleshooting

T946Z023H01 00/11PPIMA11/00-04K

Power consumption

Airflow volume

Room size

Weight

Dimension(H×W×D)

Power cord length

Safety devices

Accessories

MA-EF503HS-UAC120V 60Hz

233 Sq.FT 155 Sq.FT 13 ft × 18 ft 11 ft × 14 ft

17.1lbs (7.6 kg)

15-3/4" × 22-7/32" × 7-7/8"(400mm × 564mm × 200mm)

8.2 ft (2.5m)

MAX

HIGH

MED

LOW

MIN

MAX

HIGH

MED

LOW

MIN

36W

26W

19W

17W

16W

106 CFM

90 CFM

65 CFM

46 CFM

34 CFM

66W

28W

19W

17W

16W

160 CFM

102 CFM

65 CFM

46 CFM

34 CFM

MIT

SU

BIS

HI E

LEC

TR

IC A

IR P

UR

IFIE

R M

A-E

F503H

S-U

• MA

-EF

303HS

-U

Model

Power supply

Current fuse (2A), motor overheat protection device (operational temp: 212°F (100°C)), abnormal electric discharge protection device

Remote controller (type AA battery × 2)

MA-EF303HS-U

Specifications

For more information, visitwww.plasmapure.comor call 1-866-475-2762