placi_osb_catalog_general_en_49632.pdf
Transcript of placi_osb_catalog_general_en_49632.pdf
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
1/28
EGGER CONSTRUCTION
Wood based panels for useintimber construction
PROFESSIONAL
www.egger.com
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
2/28
Architects, Joiners and Home owners appreciate thebeauty, flexability and advantages of using woodas a building material. Engineered wood productsmade by EGGER fulfil these expectations.
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
3/28
EGGER CONSTRUCTION MORE FROM WOOD
WITH A TOTAL OF PLANTS, EGGER RANKS AMONGST
THE LEADING PRODUCERS OF WOODBASED MATERIALS
IN EUROPE.
The EGGER group has made it their mission to provide durable wood-based
products and solutions with lasting value for the construction and interior
design industries. Our wood based products are the ideal answer for
construction and decorative applications. Their special characteristics allow
you to plan and carry out work of the highest quality with confidence.
EGGER carefully selects its raw materials and uses state-of-the-art
technology to give its high-quality wood-based materials a new dimension.
This fulfills two market requirements:
Technical construction material with certified performance potential,
which meets all the requirements of CE-marked construction products.
Certified environmentally-friendly wood-based materials e.g. with IBU
environmental product declaration in accordance with ISO .
Our plant in Wismar, Germany has been certified in accordance with
ISO since 2001. Chain-of-custody certificates are available
for the PEFC and FSC systems. EGGER is a global supplier of tested and
certified wood construction products along with an array of other
applications, satisfying system solutions for planners, architects and
fabricators. Committed employees with sales and technical advice are
on hand to provide support for our customers projects.
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
4/28
EGGER wood-based panels satisfy the needs of the customerthrough high quality, application-optimised panel sizesand by our product experts and logistics service.
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
5/28
EGGER WOOD CONSTRUCTION
EXTERIOR WALL WITH FUNCTIONS
FACADE SYSTEMS THE CHOICE IS YOURS
INTERNAL WALL
As well as providing reinforcement, EUROSTRANDOSB
also acts as a vapour barrier (sd-value > 2.0 m). In vapour
permeable constructions, there is no need to invest
extra labour on installing a vapour barrier. The OSB-layer
also provides a suffi cient degree of airtightness on patchedjoints, installations and permeations. EGGER DHF is used
on the outside of walls as an external diffusion-open
(sd-value < 0.2 m) and windproof layer behind a ventilated
facade. This protects the structure during the construction
phase, allowing interior work to proceed to schedule. For
constructions with special sound-proofing and thermal
insulation requirements an external layer of EGGER DFF e.g.
beneath larch wood planking is recommended.
We have a variety of interesting cladding options for you to
choose from. From the modern thermal insulation composite
systems (TICS), with a classic rendered facade or a quarter-brick
effect, through curtain wall facades to the popular wooden facades
in the form of laths, planks or shingling. You can have any
colour or type you wish. Even demanding architectural
requirements can be fulfilled using these systems.
Its superb technical properties and varied formats even with
tongue and groove profile make EUROSTRANDOSB ideal for use
in internal walls. With EUROSTRANDOSB it is easy to attach
loads such as cupboards or shelves to the wall surfaces withoutrequiring special dowels. Another advantage of EUROSTRAND
OSB TOP is that it gives you the option of reducing the
distances between the nail and the edge of the board in
question. This allows the wood cross section of the load-
bearing structure to be optimised and thereby reduces the
heat loss through the wooden supporting structure.
TICS (e.g. StoTherm Classic)
Brick cladding with air space
1.Plaster boards
2.Insulated service cavity
3.EUROSTRAND
OSB TOP 15 mm4.Cellulose insulation
5.EGGER DHF 15 mm
6.Vertical lathing
7.Weatherboarding
1.Plaster boards
2.EUROSTRANDOSB TOP 15 mm
3.Cellulose insulation
4.EGGER DFF 30 mm
5.Horizontal lathing
6.Larch wood planking
vapour permeable construction with EUROSTRANDOSB
as interior vapour control layer
easy to make air tight
storey-high sheathing
high loadbearing capacity
Benefits on a view
easy handling
improved noise control
fastening with staples, nails and screws
suitable for hanging shelves
Benefits on a view
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
6/28
CEILING AND FLOOR CONSTRUCTIONS
DETACHED HOUSE STFLOOR WITH BASIC REQUIREMENTS
CONSTRUCTION WITH ADVANCED REQUIREMENTS APARTMENT BUILDING
The quality of living spaces depends on the quality of the
sound insulation. A well planned construction can prevent
any undesired influences and disturbances. The minimum
requirements are set out in the relevant standards. Additional
sound proofing requirements must be specially agreed with thedeveloper.
1.EUROSTRANDOSB TOP 18 mm
2.Concrete blocks
3.Impact sound insulation board
4.EUROSTRANDOSB TOP 22 mm
5.Still air layer
6.Mineral fibre
7.Cross joists
8.Plaster boards 12.5 mm
1.EUROSTRANDOSB TOP 22 mm
2.Mineral fibre
3.Expanded perlite filling
4.Sisalit trickle protection
5.EUROSTRANDOSB TOP 22 mm
6.Still air layer
7.Mineral fibre
8.Resilient channel
9.Plaster boards 12.5 mm
At a centre-to-centre span greater
than 62.5 cm (i.e. reconstruction of
old buildings) for a fire resistance of
30 minutes EUROSTRAND
OSB TOP, 30 mm, T&G, size
3000 1250 mm is recommended.
Benefits on a view
Sound insulation products for the use in timber floors
provide an acoustic impedance refered to length
of r > kN s/m
Note
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
7/28
FLOATING FLOOR WITH EGGER DFF ANDEUROSTRANDOSB
FULLYINSULATED PITCHED ROOF MODERN ROOF STRUCTURE WITH EGGER DFF WOOD FIBRE INSULATION
CONVENTIONAL STRUCTURE WITH ESSENTIAL SARKING MEMBRANE
FLOATING FLOOR WITH EUROSTRAND OSB
With a measured reduction in impact
noise Ln,w = 20 dB in solid ceilings in
accordance with DIN EN ISO - and
excellent Ln,w = 7 dB in wood-beamceilings following DIN EN ISO -,
EGGER DFF boards, in conjunction with
15/18 mm OSB flooring boards, are also
suitable for floating floor systems on new
builds, restorations and renovations.
Here the circumferential tongue and
groove profile allows for easy, tight,
installation of the boards for uniformly
high sound protection. With dimensions
of 2.50 0.675 m, the EGGER DFF boards
are very easy to use even in existing
buildings due to their light weight(14 kg/board).
Of all construction elements, the roof
is the most exposed to weather and
environmental influences. Its design and
construction are therefore of particular
importance. EGGER offers two system
solutions for this field of application.
EGGER DFF as rigid underlay is ideal for
thermal and sound insulation require-
ments, while EGGER DHF is perfect for
additional structural and fire protection
requirements. Use of loft space as living
quarters places whole new demands on
roofs. Requirements such as summer
overheating protection, thermal
insulation in the winter, as well as
appropriate sound proofing and fire
protection can easily be met.
U value = 0.18 W/mK
Phase shift 8 hours
U value = 0.35 W/mK
Phase shift 7 hours
1.Floor covering
2.EUROSTRANDOSB TOP 18 mm
3.EGGER DFF 30 mm
4.Floor load (e.g. footpath flagstones)
5.Structural ceiling
1.Plaster boards 12.5 mm
2.EUROSTRANDOSB TOP 15 mm
3.Mineral fibre
4.EGGER DFF 30 mm
5.Counter lathing
6.Cross joists
7.Roofing tiles
1.Cement lime plaster
2.HWL board
3.Mineral fibre
4.Still air layer
5.Sarking membrane
1.60 m
6.Counter lathing
7.Cross joists
8.Roofing tiles
The use of EGGER DHF/DFF reduces
thermal bridges effect of the rafters.
Improvement of the summer heat
protection and the noise control. Easy and quick installation supported
by nailing lines at the surface.
Benefits on a view
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
8/28
Airtight roof construction
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
9/28
SPECIAL APPLICATIONS
ROOF CONSTRUCTIONS FOR HALLS WITH
REQUIREMENTS TO FIRE RESISTANCE
METAL ROOF COVERING ON EUROSTRAND OSB
Roof constructions with metal covering and a subconstruction
made of OSB boards have been successfully used for several
years. Tests carried out by WKI Braunschweig on the withdrawal
strength of fasteners and by I.F.I. Aachen on durability
properties under dynamic wind loads confirmed the suitabilityof EUROSTRANDOSB E and OSB TOP for this area of
application.
This panel type is offered in particular for the design of roof
and floor constructions with wide spans and requirements of
30 minutes fire protection.
As T&G-panel with the size of 3000 1250 mm the intended
use of this panel is the installation of disk supported
frameworks (roof, floors, walls) with large spans up to 1.50 m
in particular for shop buildings. The panel has an optimal size
of 3.0 m length which reduces waste when cutting to size.
Calculated according to EUROCODE EN -- the
EUROSTRANDOSB with 30 mm thickness and a burn-uprate of 0.9 mm/minute provides a fire protection function
of 33 minutes.
NONVENTILATED ROOF STRUCTURE WITHEUROSTRANDOSB E AND/OR OSB TOPNOT TO SCALE
Roof covering with EUROSTRANDOSB TOP
CONSTRUCTION RECOMMENDATIONS
Only use EUROSTRAND OSB E and OSB TOP
Board thickness 22 mm
Recommended board size 2500 1250 mm
Fasten the wall attachment/diaphragm attachment with
ring nails (stainless steel)
Moisture content of wooden construction (rafter) < 20 %
Upper sided cover over the OSB with structured underlay,
improves sound-proofing by up to 6 dB Correct construction planning and execution with regard
to thermal insulation and moisture protection
Observe any fire protection requirements
(airborne ember and radiating heat)
Observe the recommendations of the metal roof
and membrane manufacturers!
1. Metal roof (double skin partition)
2.Structured separation layer (e.g. Delta by Drken)
3. 22 mm EUROSTRANDOSB TOP4.Rafters
5. Thermal insulation 200 mm
6.Vapour barrier in accordance with meltwater calculation
7. EUROSTRANDOSB E or OSB TOP 15 mm
8.Plasterboard (optional)
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
10/28
The assembly hall of the Pilatus Aircraft Ltd. inStans, Switzerland, with an area of 8800 m is builtalmost completely out of wood. The decision to useEUROSTRANDOSB TOP and EGGER DHF as structuralsheathing of wall and roof beneath faade and metalroof cover was taken because of the outstandingtechnical performance of these panels.
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
11/28
Our plant in Wismar, Germany has been certified in accordancewith ISO since 2001.
Most modern technology: With our 38.7 m ContiRoll we guaranteeflexibility and variety of panel sizes up to 11.5 2.8 m.
EGGER ENGINEERED WOOD PRODUCTSFOR USE IN CONSTRUCTION
EUROSTRANDOSB is the right choice as a supporting and
bracing element for walls and ceiling elements for all constructive
applications with high load-bearing and dimensional stabilityrequirements. Specially matched to the relevant field of
application, the strength classes OSB/ and OSB E are
available in accordance with EN and OSB TOP (with
formaldehyde-free adhesive) in accordance with building
regulations approval Z-.-. The separate strand preparation
for the surface and core layers, the specific strand geometry
and a high degree of orientation of the strands ensures optimum
technical properties and the highest possible degree of safety
in construction planning.
EUROSTRANDOSB
SERVICE CLASS
TONGUE AND GROOVE PROFILE
According to ENV -- (EC) EUROSTRANDOSB E,
OSB TOP can be used in service class (dry conditions) and
(humid conditions), and EUROSTRANDOSB/ in service class .
The asymmetrical, conical tongue and groove profile of the
board and cladding panel guarantees exact and rapid construction
of floors, roofs and walls and the required stress transfer on
braced (diaphragm action) board connections. In addition, it
also improves the windproofness of the construction.
In the context of the permission was regulated:
Design values for fasteners like screws, staples, and nails.
That enables to design the distribution of loads directly into
the EUROSTRANDOSB TOP panels.
Structural glueing of the unsanded panels at edge and surface
with approved PU glue from the Purbond HB product range
(type HB , , )
Note
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
12/28
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
13/28
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
14/28
Thickness [mm]Strength values [N/mm]
Bending Tension Compression Panel shear Planar shear
tnom fm ft fc fv fr
. . . .
Thickness [mm]Mean stiffness values [N/mm]
Bending Tension Compression Panel shear Planar shear
tnom Em Et Ec Gv Gr
Thickness [mm] Mean stiffness values [N/mm]
tnom fh
.
Load durationclass
kmod kde f
SC SC SC SC
medium . .
. .short . .
instantaneous . .
Property Standard Unit Value
Density EN kg /m
Diffusion resistance /Sd- Wert EN - /m /.
Thermal conductivity nominal value D EN W/mk .
Thermal conductivity calculated value R EN W/mk .
Thermal resistance R EN mK/W .
Specific heat capacity c EN J/kgK
Building materials class DIN - B normal flammability
Reaction to fire (Euroclass)) EN - C-s, dFormaldehyde emission EN mg / g atro . (E < . ppm)
Calculated values for the modification factor kmodand the deformation coefficient kdef,
in accordance with DIN :-, type MBH.LA table F and F
CHARATERISTIC VALUES FOR STRENGTH AND STIFFNESS
*in accordance with WKI-testreport, no. B /
Static design according to Eurocode .The modification factor kmodand thedeformation coefficient kdefcan be used forstatic measurement in accordance withEurocode (EN --:) in:SC = service class = dry conditions andSC = service class = humid conditions.
The properties and characteristics of EGGER DFF fulfill the requirements of EN :.Thermal insulation products for buildings Factory-made wood-fibre [WF] products andtherefore it bears the CE marking.
EGGER DFF VAPOUR PERMEABLE, MOISTURE REGULATING WOOD FIBREBOARDS
DFF was specially designed by EGGER for use as a vapour
permeable light exterior cladding for roof and wall construction.
When used as a sub-roof board all of its advantages become
obvious. Here the board can be used as a second water-bearing
layer. Its useful insulating properties help protect against
summer heat input in the construction and improves the noise
control of the structure. EGGER DFF boards have been tested for
use as impact sound insulation boards under floating
EUROSTRAND OSB boards. Further application examples can
be found in this brochure on page 4/5.
EGGER DHF IN ACCORDANCE WITH Z.
CALCULATION VALUES WITH RESPECT TO BUILDING PHYSICS AND CHARACTERISTICS
EGGER DFF ACC. TO EN
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
15/28
max. 80 cm
Remove the steel bands on site
Package protected by film cover
For acclimatisation on site:Boards secured in the corner of a room
For acclimatisation on site:Boards propped up by battens
Vapour permeable and airtight constructionsprovide a long life span of the building.
PROCESSING RECOMMENDATIONS
The following instructions also apply to EUROSTRANDOSB,
EGGER DHF and EGGER DFF. These are essential for correct
use of the boards.
STORAGE AND TRANSPORT
Correct storage and protective measures during transport areessential for problem-free handling. The following simple
principles should be taken into account:
EUROSTRANDOSB, EGGER DHF and DFF boards should be
stored flat on several pieces of squared timber. The span
width should be no greater than 80 cm and the pieces of
squared timber should all be the same height. If several pallets are stacked on top of each other then
the squared timber should be aligned by height. Steel bands should be undone immediately in the fabricators
storeroom to prevent compressive strain on the pallet.
Upright storage (practically vertical) is only suitable for asmall number of boards on a dry floor. Tongue and groove
boards In this case, only stand them on the groove side. In the case of transport by forklift truck the squared timber
chosen must be suffi ciently high so as to prevent damage. The boards must be suffi ciently protected against weathering
before being packed (closed lorry tarpaulin, polythene
sheeting). Storage rooms should be uniformly air conditioned and free
from large moisture and temperature fluctuations. Before using the boards, a 48-hour period is recommended
to allow the wood to acclimatise to local humidity.
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
16/28
Relative humidity (RH) at C Wood-based material approx. equilibriummoisture Application
Service class , % to %Dry conditions
% to %Installed dry,no moisture during usage.
Service class , % to %Humid conditions % to %
Occasional increase in humidity during use;Installed externally under roof. No directweathering.
MOISTURE PROTECTION
EUROSTRANDOSB is characterised by low thickness swelling
and a high degree of dimensional stability (see technical data:
dimensional changes under influence of moisture). When used
as a supporting and bracing element, appropriate measures
should be taken against weathering. According to EN/TS wood and wood-based materials with the following equilibrium
moistures (see table) are fit for use if installation is carried out
correctly and no impermissible condensation can form.
Dry screeds consisting of wood-based materials should only
be laid in enclosed buildings once windows and doors have
been fitted. When installation is carried out in rooms without a cellar
below, ensure suffi cient thermal insulation to prevent
condensation forming on the underside of the board and
possible warpage to the floor. In the case of concrete ceilings install a vapour barrier first.
PE film with d > 0.2 mm which overlaps joints by 30 cm and
can be installed right up to the upper edge of the floor is
suitable.
The board moisture should correspond to the local humidity
where it will be installed. In the case of floor joists made of dry wood note that u < 15 %,
since shrinkage of the subconstruction can result in long-term
squeaking noises. When using wet construction materials, such as plaster,
paint and wallpapering the resulting high humidity should be
dispersed by adequate ventilation or other suitable means.
Wood and wood-based materials must not take in moisture
from the surrounding construction components. If the floor cannot be immediately installed after the dry
screed has been laid then the board surface must be covered
with a PE film or other suitable material to prevent it drying
out or becoming more moist on one side, leading to
deformation (cupping, buckling).
EQUILIBRIUM MOISTURE OF WOODBASED MATERIALS
The use of EUROSTRANDOSB as a vapourcontrol layer at the inside of vapour permeableconstructions guarantees a suffi cient highsafety against condensation risk.
Board thickness
Board type/permissible service class
Compliance mark
CE marking
Before installation the following should be inspected on site:
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
17/28
> dn
EUROSTRANDOSB TOP > dnOSB/, OSB/ > dn
dnNail diameter
dn
dn
Installation
Fastening recommendation for nonload-bearing EUROSTRANDOSB,EGGER DHF and DFF boards
DISPOSAL
SAW DRILL MILL
FASTENING
IF BOARDS WILL BE VISIBLE ONCE INSTALLED,NOTE THE FOLLOWING FOR A GOOD CUT:
In its delivery condition, wood waste can be used as a material
or for the production of energy. In this case it is classified according
to Appendix III of the Waste Wood Ordinance to (EWC Codes)
, or . According to the waste code, it will be
decided by local waste laws what form the disposal will take.
EUROSTRANDOSB can be sawn and milled like solid wood
using conventional electrical hand tools. We recommend the
use of hard-metal cutting tools.
EUROSTRANDOSB can be attached with all fasteners suitable
for chipboard, such as screws, staples and nails. The length of
the nail/screw should be 2.5 board thickness and at least
50 mm. With staples, a minimum wire gauge of 1.53 mm should
be used. Corrosion resistant fasteners, e.g. made from galvanised
or stainless steel, are to be used. Due to the high withdrawal
strength, only flat-head nails with gutter groove, screw nails or
annularly threaded nails should be used (see also DIN -).
The crosswise orientation of the strands in the EUROSTRAND
OSB creates a secure base for the fastener, even in the outer-
most board edge. The thick core-layer structure ensures a high
withdrawal strength around the edges.
Sharp tool Workpiece must not vibrate Correct saw blade overhang
Select a slightly lower feed rate compared to solid wood. Weara respiratory mask if using hand tools without a dust extraction
device. EUROSTRANDOSB can be drilled with all suitable
electronic and manual machines suitable for solid wood.
reduced edge distances for fasteners
EUROSTRANDOSB TOP edge distance > dn
Optimized timber cross sections
Benefits on a view
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
18/28
EUROSTRANDOSB is the right choice for allapplications with high requirements accordingto load duration and dimensional stability.
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
19/28
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
20/28
EGGER DHF AND DFF SPECIAL INSTRUCTIONS
EGGER DHF AND DFF AS SUBROOFING ON THE RAFTERS
UNDERLAY CLASSIFICATION
ADDITIONAL GLUING
EGGER DHF and DFF are vapour permeable underlay boards. They form a second
water-repellent layer under the roof covering. They can be used on roofs with a minimum
pitch of 16 with a max. 8 below the standard roof pitch (SRP) of the planned roof
decking. They are installed with the tongue and groove joints from the eaves to the
roof ridge, with tongues pointing towards the ridge. In the case of a shortfall of morethan 8 the standard roof pitch must be a rain and water tight subroof. With a board
thickness 15 mm EGGER DHF, as rafters, is walkable up to a rafter grid of m acc. to
ONR - (dry board). This does not apply to EGGER DFF.
As interlocked underlay (boards with circumferential tongue and groove profile), the
boards are assigned to Class 3 according to the ZVDH guidelines. EGGER DHF and
EGGER DFF can be installed without an additional nail sealing strip under the counter-
batten and without taping the tongue and groove joint, even in case of elevated
requirements and with a roof pitch up to 8 less than the regulation pitch. Compliance
with the minimum roof pitch of 16 is mandatory. Openings (for chimneys etc.) and
joints (covings, groins, dormers etc.) must be taped using suitable adhesive tape.
A taped underlay must be implemented when the roof pitch is less than the regulation
pitch of 16 by a maximum of 8. All board joints are taped using suitable adhesive
tape. The minimum roof pitch is 10.
Increased requirements in addition to shortfall of standard roof pitch:
Use of attic, especially as living space Special construction features, e.g. dormer windows, ridges, complicated roof shapes Climatic factors, e.g. mountains or coasts Local requirements, e.g. from building control
UNINSULATED COCKLOFT
TRANSIENT WEATHERING
The roof area of an uninsulated cock-loft and an unconverted attic must also be
ventilated even by using a vapour permeable sub-roofing material. The recommended
ventilation cross-section, derived from the regulations for the ventilation of flat roofs
is 200 cm per running meter at the ridge and the eaves.
After installing EGGER DHF and DFF the roof covering/facade should be fitted
immediately. Between March and November the boards can be exposed to natural
weathering for 2 months as a temporary roof. In the winter months, structural
measures must be employed to ensure that the external covering layer of EGGER DHF
cannot freeze, since this would seriously impair the diffusion ability of the external
panelling cladding and potentially lead to moisture damage. In the winter months it
should only be exposed to natural weathering for a maximum of 2 weeks. If EGGER
DHF is used for load-bearing purposes then the moisture protection regulations of the
approval Z-.- apply and DIN -, i.e. the fitted boards have to be protected
from natural weathering.
EGGER DHF/DFFused as rigid underlay
Ventilation of uninsulated cock-loft
During the winter months, icing of
the outer layer of the EGGER DHF
board must be excluded by means
of suitable construction measures,
since this would severely impair the
diffusion characteristics of exterior
sheathing, which may result in
moisture damage.
Note
If the pitch of the roof is less then 8
further measures should be taken
to ensure rain and water tightness
of the roof covering (i.e. taping theEGGER DHF/DFF panel joints).
Note
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
21/28
Timber studdistance ar(cm) *
Fv(KN/ar) perm iss ible
Wall panels in the height h under horizontal stress
h = . m h = . m h = . m
mm mm mm mm mm mm mm mm mm
. -ar . . . . . . . . .
-ar . . . . . . . . .
. -ar . . . . . . . . .
-ar . . . . . . . . .
. -ar . . . . . . . . .
-ar . . . . . . . . .
. -ar . . . . . . . . .
-ar . . . . . . . . .
DIMENSIONING
Wooden structures are designed according to the appropriate National and European
standards. In the medium-term, Eurocode has been introduced as an EU-wide
regulation for the design of wooden constructions. Characteristic values for the
structural design of EUROSTRANDOSB in accordance with Eurocode can be
taken from DIN EN - or from the building authorities.
The following assessment tables were created using the regulations for EUROSTRAND
OSB TOP in accordance with approval Z-.- as well as the rules for the assessment
of wooden constructions in accordance with Eurocode .
LOADING TABLES FOR EUROSTRANDOSB
PREDIMENSIONING OF WALL PANELS FOR HORIZONTAL FORCE
The calculation is based on the regulations in DIN -:, section: .. on the
testing of tensile force on the board. To prevent the planking from buckling, the timber
stud distances should be limited to ar= 83.3 cm.
* Panel with one, two or three timber stud distances ar.In the case of double-sided planking, double the permissible Fv(KN/ar) values.
WALL PANELS IN THE HEIGHT H UNDER HORIZONTAL STRESS
Horizontal force allowable Fv(KN/ar)
ASSUMPTIONS
The longitudinal edge of the board runs parallel to the wall studs. There are no
horizontal joints in the area. The nailing is carried out using staples with 1.8 mm wire
gauges with a length of 55 mm and a clearance of 50 mm; N1 = 280 N permissible.
The tables contain recommended
values and are not intended as a
substitute for individual verification
by a structural engineer.
Note
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
22/28
Needed board thickness d (mm)
qk/ Qk . / . . / .
gk gk
ar(cm) . . . . . .
.
.
.
.
.
.
.
.
. 40
Edge Condition: b = 1,25 m Individual load flat taken
PREDIMENSIONING OF HORIZONTAL PLANKING AS DOUBLESPAN BEAM FOR VERTICAL LOADS
The following table specifies the required board thickness with the application of vertical loads only
(e.g. shelving, sheathing wood beam layer) without plate effect, dependent on the ridge retention ar.
PREDIMENSIONING OF SINGLE GIRDER WITH EUROSTRANDOSB E
Needed board thickness d (mm)
qk/ Qk . / . . / .
gk gk
ar(cm) . . . . . .
.
.
.
.
.
.
. * *
. * * * * *
. * * *
. * * *
Edge Condition: b = 1,25 m Individual load flat taken
PREDIMENSIONING OF SINGLE GIRDER WITH EUROSTRANDOSB TOP
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
23/28
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
24/28
EGGER DHF as structural sheathing, up to3.0 m storey high sheathing in classifiedwall structure REI acc. to EN -
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
25/28
Timber studdistances ar(cm)
Fv(KN/ar) pe rm iss ib le
Wall panels in the height h under horizontal stress
h = . m h = . m h = . m mm mm mm mm mm mm
.* -ar . . . . . .
.** -ar . . . . . .
EGGER DHF
PREDIMENSIONING OF WALL PANELS
ASSUMPTIONS
The following design tables are based on one-sided external panelling of the
supporting structure using EGGER DHF. The calculated values for humid conditions
(service class ) are used. The calculations were carried out in accordance with the
regulations set out in DIN -:-, .., on the testing of tensile force onthe board.
The longitudinal edge of the board runs parallel to the wall studs. There are no
horizontal joints in the area.
The nailing is carried out using clips with 1.53 mm wire gauges with a length of
55 mm and a clearance of 50 mm; N1= 250 N permissible.
Sheathing thickness d=13mm/15mm (0.51 / 0.59)
* Panel with two timber stud distances ar.** Panel with three timber stud distances ar.
IMPORTANT DOCUMENTS AND STANDARDS
Additional processing instructions and application examples
can be found at/in:
www.egger.com
Eurocode EN -- Timber construction in conjunction
with the nationally applicable usage document (national
timber construction standard)
EN/TS Wood-based panels. Guidance on the use of
load-bearing boards in floors, walls and roofs
The following design tables are
recommendations. They cannot
replace the static calculation by a
permitted civil engineer.
Note
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
26/28
Picture: Production of export cases made ofEUROSTRAND OSB according to ISPM Standard
Picture: Shelf and storage system Schottelcompany, Wismar, EUROSTRAND OSB TOP
Picture: Airport Munich, Terminal 2,EUROSTRAND OSB E, 20 mm, as concrete shuttering
Picture: I-beam production with EUROSTRANDOSB E
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
27/28
We reserve the right to make changes to the stock program.
*on request (by load)
** Delivery by request, production as individual customer order 250 m (8,829 cubic feet)
Product/
length width (mm)
Board thickness d (mm)
EUROSTRAND OSB TOP Z-.-
Straight edge unsanded
* *
*
*
**
T&G unsanded
T&G sanded
T&G unsanded
**
EUROSTRAND OSB E EN
Straight edge unsanded
* * * *
* *
*
** ** *
T&G unsanded
T&G sanded
T&G unsanded
EUROSTRAND OSB/ EN
Straight edge unsanded
EGGER DHF underlay boards acc. to Z-.- / EN - MDF.RWH
T&G unsanded
T&G unsanded
EGGER DFF insulating boards acc. to EN
T&G unsanded
STOCK PROGRAM EUROSTRANDOSB AND EGGER DHF AND DFF / PLANT WISMAR
-
8/9/2019 placi_osb_catalog_general_en_49632.pdf
28/28
alterations.
Withoutguaranteeforprintingerrors,
standarderrorsand
mistakes.
www.egger.com
Distributed by:
FRITZ EGGER GmbH & Co. OG
HolzwerkstoffeWeiberndorf 20
6380 St. Johann in Tirol
Austria
+43 50 600-0
+43 50 600- 10111
EGGER Holzwerkstoffe
Wismar GmbH & Co. KG
Am Haffeld 1
23970 Wismar
Germany
+49 3841 301-21260
+49 3841 301-61260
EGGER (UK) Limited
Anick Grange Road
Hexham, Northumberland
NE46 4JS
United Kingdom+44 1434 602191
+44 1434 605103